This is Amendment 0002 to an RFQ (Request for Quotation) for heat exchanger repair services at the Department of Veterans Affairs Eastern Colorado Health Care System. The solicitation (36C25927Q0038) seeks correction and rebuild services for shell and tube heat exchangers as a one-time service requirement for the Rocky Mountain Regional VA Medical Center located at 1700 N. Wheeling Street, Aurora, Colorado 80045. The scope of work includes installation of new valves (ranging from 6-inch to 8-inch sizes), cleaning and rebuilding of shell and tube heat exchangers, and replacement of associated gaskets and seals as required. The equipment is distributed across multiple facility locations at the medical center, with existing piping identified as black iron piping. All equipment is manufactured by the same manufacturer.
The quotation due date has been extended to November 12, 2026, at 12:00 PM Mountain Time. Amendment 0002 provides site visit photographs and additional information gathered during the approved site visit held on November 9, 2026, to assist offerors in preparing their quotations. Offerors are required to review all solicitation documents, site visit documentation, and photographs in conjunction with specifications to develop comprehensive pricing and technical proposals. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19, with inquiries directed to Contract Specialist Eric Adusei at eric.adusei@va.gov.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Site Visit Pictures 1.pdf | ||
| 36C25927Q0038 0001.docx | DOCX document | |
| 36C25927Q0038.docx | DOCX document | |
| PWS Rebuild of Heat Exchangers.docx | DOCX document | |
| Wage Determination 2015-5419.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| Correction and Rebuild of Shell and Tube Heat Exchangers: One time Service |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 80111 |
| SOLICITATION NUMBER* |
| 36C25927Q0038 |
| RESPONSE DATE/TIME/ZONE |
| 11-12-2026 12:00 MOUNTAIN TIME, DENVER, USA |
| ARCHIVE |
| 5 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SBA |
| PRODUCT SERVICE CODE* |
| J045 |
| NAICS CODE* |
| 811412 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village CO 80111
POINT OF CONTACT*
Contract Specialist Eric Adusei eric.adusei@va.gov 303.712.5753
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veteran Affairs |
Eastern Colorado Healthcare System
Rocky Mountain Regional VA Medical Center
1700 N. Wheeling Street
Aurora CO
| POSTAL CODE |
| 80045 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
Amendment 0002 Notice The purpose of Amendment 0002 to RFQ 36C25927Q0038 is to post photographs taken during the site visit and provide additional information that was discussed during the site visit to assist offerors in preparing their quotations.
Offerors are encouraged to review the attached document labeled "Site Visit 1," which contains photographs taken during the site visit. These photographs are being provided for informational purposes and may assist offerors in understanding the existing site conditions, equipment configurations, access constraints, and installation environment when preparing their quotations. Offerors should review the photographs in conjunction with all solicitation documents, specifications, and requirements to ensure a complete understanding of the scope of work.
Additional Information from the Site Visit Offerors are advised of the following information discussed during the site visit:
1. The equipment requiring service includes varying valve sizes, including 8-inch and 6-inch valves. All equipment is manufactured by the same manufacturer.
2. The scope of work includes the installation of new valves, the cleaning and rebuilding of shell-and-tube heat exchangers, and the replacement of associated gaskets and seals as required.
3. The equipment associated with this requirement is located at the Rocky Mountain Regional VA Medical Center and is distributed among multiple facility locations.
4. Existing piping associated with this requirement was identified during the site visit as black iron piping.
Offerors should consider this information, together with the solicitation requirements and site visit documentation, when developing and submitting their quotations. Additionally, the quotation due date is hereby extended as identified in this amendment.
See attached document: Site Visit Pictures 1.