Attachment B Steris Sterilizer Preventive Maintenance Schedule COMBINED.docx

DOCX document 29 KB Posted

Attached to
J065--Actionable - 554 (S) | New Requirement | Biomed Steris Sterilizer Maintenance (VA-26-00024834)
Solicitation number
36C25926Q0115
Issued by

About this file

The document is an Attachment B Preventive Maintenance Schedule detailing maintenance requirements for biomedical and research equipment at the Eastern Colorado Healthcare System. The schedule encompasses two categories of equipment: biomedical engineering and research equipment, with specific maintenance frequencies for various Steris sterilizers, washers, and related devices. Each equipment type has detailed periodic maintenance requirements, ranging from daily (such as drain cleaning and debris screen inspection) to annual original equipment manufacturer (OEM) preventive maintenance checks.

The associated federal contract opportunity is a Request for Quote (RFQ) #36C25926Q0115 issued by the Department of Veterans Affairs Veterans Health Administration for Steris Sterilizer Maintenance. The solicitation is 100% set-aside for small businesses, with a base year and four option years of scheduled and unscheduled maintenance for biomedical and research lab equipment. The quote submission deadline is 16:00 MT on January 05, 2026, with a anticipated firm-fixed price contract. The period of performance for the base year is 03/01/2026-02/28/2027, with subsequent option years extending through 02/28/2030. The NAICS code is 811310 with a business size standard of $12.5 Million.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment B – Preventive Maintenance Schedule (Biomedical Engineering Equipment)

Equipment
PM Frequency
OEM Requirements
Vision 1327 Washer
Daily / Weekly / Monthly / Quarterly
Daily debris screen cleaning; Weekly arm inspection; Monthly gasket inspection; Quarterly full OEM PM.
5052 Washer/Disinfector
Quarterly (4×/year)
OEM Quarterly PM; Inspections 1 & 3 include required parts replacement.
AMSCO HC‑1500 Steam Sterilizer
Daily / Weekly / Annual
Daily drain strainer cleaning; Weekly leak test; Annual chamber cleaning and OEM PM.
SCS‑M‑F1 Conveyor
Daily / Quarterly / Annual
Daily roller & guide cleaning; Quarterly drip pan cleaning; Annual lift-gate verification.
400 Series Model 16 Sterilizer
Daily / Weekly / Annual
Same OEM routine as HC‑1500: daily drain cleaning, weekly leak test, annual OEM PM.
Caviwave Ultrasonics
Semi‑Annual (2×/year)
Semi‑annual OEM PM including transducer testing, calibration, and parts replacement.
V‑PRO Max Low‑Temp Sterilizer
Daily / Weekly / Monthly
Daily printer check; Weekly chamber & touchscreen cleaning; Monthly leak test.
InnoWave Pro Sonic Irrigator
Daily / Weekly / Semi‑Annual
Daily inspections; Weekly deep cleaning; Semi‑annual OEM service.

Preventive Maintenance Schedule (Research Equipment)

Equipment
PM Frequency
OEM Requirements Summary
Amsco SV‑160S Prevac Sterilizer
Annual + Daily/Weekly
Annual OEM PM: calibrations, chamber service, valve inspection, safety tests. Daily: drain cleaning. Weekly: leak test. Follow OEM SV‑160S Maintenance Manual.
Basil 4700 Cage/Rack Washer
Quarterly + Weekly/Daily
OEM Basil 4700 Tables 4‑1 & 6‑1: weekly spray jet inspection, 6×/yr sump descaling, 12×/yr electrical inspections, lubrication, filter cleaning, operational verification.
Reliance 500XLS Glassware Washer
Quarterly
Quarterly OEM PM: pumps, spray arms, filters, temperature verification, dosing calibration, gaskets. Follow 500XLS OEM PM checklist.
Amsco LV 250 Lab Sterilizer (x2)
Annual + Daily/Weekly
Annual OEM PM: recalibration, valve inspection, chamber maintenance. Daily drain cleaning. Weekly leak testing. Follow LV 250 OEM PM checklist.
Basil 3700 Cage/Bottle Washer
Quarterly
Quarterly OEM PM: spray arm tests, screens/filters, sump cleaning/descaling, pump/motor checks, calibration verific