S06 - Sign Post Detail.pdf

PDF 126 KB Posted

Attached to
Z2DA--Asphalt Maintenance and Repair | 442-23-001
Solicitation number
36C25924R0135
Issued by

About this file

This document is a technical drawing detailing sign post foundation specifications for a federal construction project at the Cheyenne VA Medical Center. The detailed technical drawing provides precise requirements for perforated square tube sign post foundations, including:

Materials specifications: Square tube posts formed from 0.105 U.S.S. gauge ASTM A-366 cold rolled carbon steel, welded by high frequency resistance welding, externally scarfed with standard corner radii, and galvanized to ASTM A-525 G-90 coating. The foundation is 12" square, with posts ranging from 1 3/4"x1 3/4" to 2"x2", and includes specific installation requirements such as being located 1' from pavement edge, perpendicular to the paved surface, and finished with landscape material. The concrete foundation must be 2500 PSI, with 7/16" diameter holes spaced at 1" on center, and hardware must conform to ASTM A-307 Class A and be galvanized or cadmium plated.

View the file

Other files

File Type Posted
S06 - 442-23-001_Signage_Utility Plan Demo.pdf PDF
36C25924R0135 0005.docx DOCX document
S06 - 442-23-001_Site Plan Reno_revised.pdf PDF
S05 - RFI Site Visit - Questions - Responses - 2nd Set - FE.docx DOCX document
S05 - RFI Site Visit - Questions - Responses - 1st Set - FE.docx DOCX document
36C25924R0135 0004.docx DOCX document
36C25924R0135 0003.docx DOCX document
36C25924R0135 0002.docx DOCX document
S06 - Site Visit Attendance - FE.pdf PDF
S06 - Site Visit Meeting Doc.docx DOCX document
36C25924R0135 0001.docx DOCX document
36C25924R0135_1.docx DOCX document
S22 - LOS - Attachment - 852.219-75 Blank -.docx DOCX document
PPQ Blank - Past Performance Questionnaire -.docx DOCX document
S02 - Site Plan Reno.pdf PDF
S02 - Site Visit Bldg 11 Directions.pdf PDF
S02 - Specifications.pdf PDF
S02 - Site Plan Demo.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NTS

MATERIALS:

1. PERFORATED POSTS SHALL BE SQUARE TUBE FORMED FROM

0.105 U.S.S. GAUGE ASTM A-366 COLD ROLLED CARBON

STEEL. THE SQUARE TUBES SHALL BE WELDED DIRECTLY IN

THE CORNER BY HIGH FREQUENCY RESISTANCE WELDING OR

EQUAL. THE POSTS SHALL BE EXTERNALLY SCARFED TO

AGREE WITH STD. CORNER RADII OF 5/32" [4mm] TO 1/64" [.3mm].

2. PERFORATED POSTS SHALL BE GALVANIZED TO CONFORM TO

ASTM A-525. COATING DESIGNATION G-90.

3. ALL HARDWARE SHALL CONFORM TO ASTM A-307 CLASS A.

4. ALL HARDWARE SHALL BE GALVANIZED TO CONFORM TO ASTM

A-153 OR CADMIUM PLATED TO CONFORM TO ASTM A-165.

5. ALL CONCRETE SHALL BE 2500 PSI.

NOTES:

1. FOUNDATION WILL BE CONSTRUCTED WITH 1 3/4"x1 3/4"

STARTER SIGN POST. STARTER SIGN POST SHALL BE

REMOVED AFTER CONCRETE HAS SET AND EXPOSED SQUARE

TUBING WRAPPED AND SEALED WITH DUCT TAPE.

2. FOUNDATION LOCATED 1' FROM EDGE OF PAVEMENT.

3. FOUNDATION LOCATION TO BE APPROVED BY ENGINEERING.

4. POST FOUNDATIONS SHALL BE PERPENDICULAR TO THE

PAVED SURFACE.

5. BOLT WITH NUT AND LOCK WASHER TO BE 7/16"x3"

GALVANIZED.

6. REFER TO SIGN POST LOCATION DETAIL, DETAIL 4, THIS

SHEET FOR INSTALLATION LOCATION.

7/16" [10mm] HOLE DIAMETER SPACED AT 1" [25mm] 0.C.

EXPANSION

MATERIAL TYP.

IN CONCRETE

AREAS.

FINISH WITH

LANDSCAPE

MATERIAL.

FINISHED

GRADE

4"

[100mm]

SIGN POST DETAIL SQUARE TUBE FOUNDATION

12" SQUARE

[300mm] m m m m m m

12" SQUARE

[300mm] m m m ]1 m m m m m m m

2"x2" [50x50mm]

PERFORATED POST

2 1/4"x2 1/4" [57x57mm]

PERFORATED POST

1 3/4"x1 3/4" [40x40mm]

PERFORATED POST 2

m m

8" SQUARE

[200mm] m m m

S C A L E

C A D

D E T A I L

N O

D A T E

I S S U E D

DE

TA

IL

T

IT

LE

S I G N

P O S T

D E T A I L

S Q U A R E

T U B E

F O U N D A T I O N

S D D W G

D E C E M B E R

N O N E

11x17

File details come from the government source that posted it. Updated .