This document is an Asbestos PLM (Polarized Light Microscopy) Report for samples collected at the VA Salt Lake City Health Care System's Building 7. The report details the analysis of 15 samples taken from various locations within the building, including ceiling tiles, block filler, gypsum wall board, duct sealant, and concrete walls. None of the samples were found to contain asbestos at concentrations greater than 1%.

The related federal contract opportunity is for the VMU (Veterinarian Medical Unit) Backup HVAC Project #660-24-102 at Building 7 of the VA Salt Lake City Health Care System. The scope of work includes furnishing all necessary services, equipment, labor, materials, supervision, and tools to perform construction services for a new VRF (Variable Refrigerant Flow) heating/cooling system to provide redundancy for the VMU when the main HVAC system is down. The work must be completed within a 90-day period of performance. The solicitation number is 36C25924Q0445.

View the file

Other files

File Type Posted
S02 - Specs 013323.docx DOCX document
VHA ICRA - 660-23-231 VMU Back Up HVAC.pdf PDF
S02 - Specs 010000.docx DOCX document
36C25924Q0445 0002.docx DOCX document
S02 - Specs 230593.docx DOCX document
S02 - Specs 238143.docx DOCX document
S02 - Specs 013526.docx DOCX document
S02 - Specs 230800.docx DOCX document
660-23-231 VMU HVAC Backup - SOW.docx DOCX document
660-23-231 VMU Back Up HVAC - Sign in Sheet.pdf PDF
S02 - Specs 232300.docx DOCX document
VMU Asbestos Doc 1.pdf PDF
VMU Asbestos Doc 3.pdf PDF
S02 - Specs 260511.docx DOCX document
S02 - Specs 230511.docx DOCX document
S02 - Specs 033000.docx DOCX document
36C25924Q0445 0001.docx DOCX document
36C25924Q0445_1.docx DOCX document
S02 - Specs 010000 --.docx DOCX document
S22- 852.219-75 LOS Certification.docx DOCX document
S02 - SAL-07-01AR Function Drawing.pdf PDF
S02 - SAL-07-01AR Service Drawing.pdf PDF
S02 - SAL-07-01AR Space Drawing.pdf PDF
S02 - Specs 013526 --.docx DOCX document
36C25924Q0445_Past Performance Questionnaire_Blank.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by:

Approved Signatory Renee Luna-Trepczynski

Report for:

Chase Maeser Terracon Consultants, Inc. - Utah 6949 S. High Tech Drive, Suite 100 Midvale, UT 84047

Regarding: Project: VAMC; Building 7

EML ID: 2561460

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 01-22-2021

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 500031-0

EMLab ID: 2561460, Page 1 of 5Eurofins Aerotech Built Environment Testing, Inc. an affiliate of Eurofins EPK Built Environment Testing, LLC d/b/a Eurofins EMLab P&K

Eurofins EMLab P&K 1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Terracon Consultants, Inc. - Utah C/O: Chase Maeser Re: VAMC; Building 7

Date of Sampling: 01-20-2021 Date of Receipt: 01-21-2021 Date of Report: 01-22-2021

ASBESTOS PLM REPORT

Total Samples Submitted: 15 Total Samples Analyzed: 15

Total Samples with Layer Asbestos Content > 1%: 0

Location: M-1-1, White 2'x2' Ceiling Tile With Small Pinholes and Gauges Lab ID-Version‡: 12213328-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 40% Cellulose 40% Glass Fibers

Sample Composite Homogeneity: Good

Location: M-1-2, White 2'x2' Ceiling Tile With Small Pinholes and Gauges Lab ID-Version‡: 12213329-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 40% Cellulose 40% Glass Fibers

Sample Composite Homogeneity: Good

Location: M-1-3, White 2'x2' Ceiling Tile With Small Pinholes and Gauges Lab ID-Version‡: 12213330-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 40% Cellulose 40% Glass Fibers

Sample Composite Homogeneity: Good

Location: M-2-4, White Block Filler Lab ID-Version‡: 12213331-1

Sample Layers Asbestos Content White Block Filler with Multilayered Paint ND

Gray Block ND Sample Composite Homogeneity: Good

EMLab ID: 2561460, Page 2 of 5Eurofins Aerotech Built Environment Testing, Inc. an affiliate of Eurofins EPK Built Environment Testing, LLC d/b/a Eurofins EMLab P&K

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Terracon Consultants, Inc. - Utah C/O: Chase Maeser Re: VAMC; Building 7

Date of Sampling: 01-20-2021 Date of Receipt: 01-21-2021 Date of Report: 01-22-2021

ASBESTOS PLM REPORT

Location: M-2-5, White Block Filler Lab ID-Version‡: 12213332-1

Sample Layers Asbestos Content White Block Filler with Multilayered Paint ND

Gray Block ND Sample Composite Homogeneity: Good

Location: M-2-6, White Block Filler Lab ID-Version‡: 12213333-1

Sample Layers Asbestos Content White Block Filler with Multilayered Paint ND

Gray Block ND Sample Composite Homogeneity: Good

Location: M-3-7, White Gypsum Board Wall System Lab ID-Version‡: 12213334-1

Sample Layers Asbestos Content White Drywall with Brown Paper and Tan Paint ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good

Location: M-3-8, White Gypsum Board Wall System Lab ID-Version‡: 12213335-1

Sample Layers Asbestos Content White Compound with Light Gray Paint ND

White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 2561460, Page 3 of 5Eurofins Aerotech Built Environment Testing, Inc. an affiliate of Eurofins EPK Built Environment Testing, LLC d/b/a Eurofins EMLab P&K

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Terracon Consultants, Inc. - Utah C/O: Chase Maeser Re: VAMC; Building 7

Date of Sampling: 01-20-2021 Date of Receipt: 01-21-2021 Date of Report: 01-22-2021

ASBESTOS PLM REPORT

Location: M-3-9, White Gypsum Board Wall System Lab ID-Version‡: 12213336-1

Sample Layers Asbestos Content White Drywall with Brown Paper and Tan Paint ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good

Location: M-4-10, Green Duct Sealant Lab ID-Version‡: 12213337-1

Sample Layers Asbestos Content Green Sealant ND

Sample Composite Homogeneity: Good

Location: M-4-11, Green Duct Sealant Lab ID-Version‡: 12213338-1

Sample Layers Asbestos Content Green Sealant ND

Sample Composite Homogeneity: Good

Location: M-4-12, Green Duct Sealant Lab ID-Version‡: 12213339-1

Sample Layers Asbestos Content Green Sealant ND

Sample Composite Homogeneity: Good

EMLab ID: 2561460, Page 4 of 5Eurofins Aerotech Built Environment Testing, Inc. an affiliate of Eurofins EPK Built Environment Testing, LLC d/b/a Eurofins EMLab P&K

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Terracon Consultants, Inc. - Utah C/O: Chase Maeser Re: VAMC; Building 7

Date of Sampling: 01-20-2021 Date of Receipt: 01-21-2021 Date of Report: 01-22-2021

ASBESTOS PLM REPORT

Location: M-5-13, Concrete Walls Lab ID-Version‡: 12213340-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Good

Location: M-5-14, Concrete Walls Lab ID-Version‡: 12213341-1

Sample Layers Asbestos Content White Skim Coat with Off-White Paint ND

Gray Base Coat ND Composite Non-Asbestos Content: < 1% Hair/Wool Sample Composite Homogeneity: Moderate

Location: M-5-15, Concrete Walls Lab ID-Version‡: 12213342-1

Sample Layers Asbestos Content White Skim Coat with Off-White Paint ND

Gray Base Coat ND Gray Concrete ND

Composite Non-Asbestos Content: < 1% Hair/Wool Sample Composite Homogeneity: Moderate

EMLab ID: 2561460, Page 5 of 5Eurofins Aerotech Built Environment Testing, Inc. an affiliate of Eurofins EPK Built Environment Testing, LLC d/b/a Eurofins EMLab P&K

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

File details come from the government source that posted it. Updated .