CODE ANALYSIS LEGEND

TOTAL OCCUPANCY

FEC

EXIT

OCCUPANCY LOAD FACTOR

EXITS REQUIRED

SQUARE FOOTAGE

OCCUPANCY TYPE

EGRESS EXIT SIGNAGE (ETR)

FIRE EXTINGUISHER CABINET (ETR)

DIAGONAL DISTANCE

EXIT SEPARATION DISTANCE (ETR)

EXISTING EGRESS PATH

2 HR - FIRE SEPARATION

1 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

B

1500 SF

REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND

REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.

ICC, INTERNATIONAL BUILDING CODES, 2018 EDITION (IBC)

FPA 80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS, 2016 EDITION

NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2015 EDITION

FPA 101, LIFE SAFETY CODE, 2015 EDITION

NFPA 220, STANDARD TYPES OF BUILDING CONSTRUCTION, 2015 EDITION.

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

EXISTING CONDITIONS MAYBE "GRANDFATHERED" INTO CURRENT CODES, GOVERNING

CODES ARE DIRECTLY APPLICABLE TO WORK THAT SHALL BE PROVIDED BY THIS

CONTRACT. CONTACT THE COR AND A/E FOR CLARIFICATIONS ON CODE/GUIDELINE

INTERPRETATIONS.

VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD

STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

NAPHS DESIGN GUIDE FOR THE BUILT ENVIRONMENT OF BEHAVIORAL HEALTH

FACILITIES

VA SPACE PLANNING CRITERIA, PG-18-9, CHAPTER 110

VA MENTAL HEALTH FACILITIES DESIGN GUIDE, DECEMBER 2010 (REV. 08/01/2014)

VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS

ARCHITECTURAL, AUGUST 1, 2014

NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010

FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015

INTERIOR DESIGN, MAY 2008

VA DESIGN MANUALS PG-18-10:

GOVERNING CODES:

REFERENCE ARCHITECTURAL PLANS AND ROOM SCHEDULE FOR PROJECT LAYOUT AND SCOPE

EXISTING ITEMS UNCHANGED ARE SHOWN HALF-TONE/GRAY

CODE CRITERIA

GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101 (LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD

PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.

NOTES:

CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

CODE REVIEW

THE 2018 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS.

FOR FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES, THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE HAS BEEN

USED.

PROJECT SCOPE

THE PROJECT SCOPE INCLUDES THE EXISTING BUILDING'S EAST WING ON FIFTH FLOOR, WHICH WILL BE MODIFIED TO IMPROVE THE PATIENT ENVIRONMENT, SAFETY AND PRIVACY. THE USE AND OCCUPANCY REMAIN UNCHANGED. THE OCCUPANCY IS A GROUP I-2, INSTITUTIONAL, INPATIENT HEALTHCARE.

CODE ANALYSIS

THE EXISTING BUILDING'S EAST WING ON FIFTH FLOOR IS UNDERGOING A REMODEL TO IMPROVE THE PATIENT ENVIRONMENT, SAFETY(IN REDUCING RISK OF SELF- HARM) AND PRIVACY. THE OCCUPANCY CLASSIFICATION AND USE TYPES AND COUNTS REMAIN UNCHANGED. THE OCCUPANCY IS A GROUP I-2, INSTITUTIONAL, HOSPITAL

INPATIENT HEALTHCARE.

THE CONSTRUCTION TYPE IS DETERMINED BASED UPON THE ALLOWABLE AREA AND HEIGHT REQUIREMENTS OF CHAPTER 5 OF THE 2018 IBC. CONSTRUCTION TYPE AND MATERIALS SHALL BE PER CHAPTER 6 OF THE IBC FOR TYPE I-A CONSTRUCTION AND LSC 1 (332) CONSTRUCTION AS FOLLOWS:

1. OCCUPANCY TYPE: I-2 INSTITUTIONAL, IBC CHAPTER 3/LSC CHAPTER 18 HEALTHCARE

2. CONSTRUCTION TYPE: I-A (IBC CHAPTER 5)

3. FIRE RESISTIVE RATINGS TYPE 1-A CONSTRUCTION, CHAPTER 6 IBC/NFPA 101:

STRUCTURAL FRAME: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE

BEARING WALLS

EXTERIOR: NONCOMBUSTIBLE, 3 -HOUR FIRE RESISTIVE

INTERIOR: NONCOMBUSTIBLE, 3-HOUR FIRE RESISTIVE

NON-BEARING WALLS AND PARTITIONS

EXTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE RESISTIVE AT GREATER THAN 30' SEPARATIONS

INTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE-RESISTIVE

FLOOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE

ROOF: NONCOMBUSTIBLE, 1.5-HOUR FIRE RESISTIVE

SHAFT ENCLOSURES 2-HOUR FIRE RESISTIVE >4 STORIES (IBC 713.4, LSC 12.3.6)

SHAFT ENCLOSURES 1-HOUR FIRE RESISTIVE <4 STORIES (IBC 713.4, LSC 12.3.6)

4. STRUCTURAL DESIGN SHALL COMPLY WITH CHAPTER 16 OF THE IBC.

5. ALLOWABLE HEIGHT: UNLIMITED FT (IBC, TABLE 504.3)

6. ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN: UNLIMITED (IBC, TABLE 504.4)

7. ALLOWABLE AREA: FULLY SPRINKLED: ALLOWABLE AREA: UNLIMITED (IBC, TABLE 506.2)

8. MEANS OF EGRESS

• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 8 FEET.

• AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN 44 IN.

CLEAR AND UNOBSTRUCTED WIDTH.

• CLEAR WIDTH OF DOORS SHALL BE CLEAR 42 INCHES FROM SLEEPING ROOMS.

• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES

• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.

• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)

9. OCCUPANCY SEPARATION: I-2 OCCUPANCY REQUIRES A 2-HR SEPARATION BETWEEN COMMON ADJACENT OCCUPANCIES (S-2, U, B, S-1, M) (IBC CHAPTER 5, LSC CHAPTER 18). NO OTHER OCCUPANCIES ARE FOUND WITHIN THE PROJECT AREA AND NONE ARE PROVIDED BY THE PROJECT.

SECTIONS OF HEALTH CARE FACILITIES SHALL BE PERMITTED TO BE CLASSIFIED AS OTHER OCCUPANCIES, PROVIDED THAT THEY MEET BOTH OF THE FOLLOWING

CONDITIONS: (LSC 18.1.3.3)

(1) THEY ARE NOT INTENDED TO PROVIDE SERVICES SIMULTANEOUSLY FOR FOUR OR MORE INPATIENTS FOR PURPOSES OF HOUSING, TREATMENT, OR CUSTOMARY

ACCESS BY INPATIENTS INCAPABLE OF SELF-PRESERVATION.

(2) THEY ARE SEPARATED FROM AREAS OF HEALTH CARE OCCUPANCIES BY CONSTRUCTION HAVING A MINIMUM 2-HOUR FIRE RESISTANCE RATING IN ACCORDANCE

WITH CHAPTER 8.18.1.3.4 CONTIGUOUS NON-HEALTH CARE OCCUPANCIES.

10. MEANS OF EGRESS

• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 8 FEET.

• AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN 44 IN.

(1120 MM) IN CLEAR AND UNOBSTRUCTED WIDTH.

• CLEAR WIDTH OF DOORS SHALL BE CLEAR 42 INCHES FROM SLEEPING ROOMS; DIAGNOSTIC AND TREATMENT AREAS, SUCH AS X-RAY, SURGERY, OR PHYSICAL

THERAPY;.

• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES

• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.

• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)

• MAXIMUM TRAVEL DISTANCE, FULLY SPRINKLED: 200 FEET (LSC 18.2.6.2.1)

• COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET (LSC 18.2.5.3)

• DEAD END CORRIDORS SHALL NOT EXCEED 30 FEET. (LSC 18.2.5.2)

• MEANS OF EGRESS SHALL BE ILLUMINATED PER 7.9. (LSC 18.2.6.2.1)

• EMERGENCY LIGHTING SHALL BE PER 7.9. (LSC 18.2.9)

• EXIT SIGNAGE SHALL BE PROVIDED 7.10. (LSC 18.2.10)

11. WHERE GENERAL ANESTHESIA OR LIFE SUPPORT EQUIPMENT IS USED AND ESSENTIAL ELECTRICAL SYSTEM PER NFPA 99 SHALL BE PROVIDED.

12. HAZARDOUS AREAS. ANY HAZARDOUS AREAS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 8.7, AND THE AREAS DESCRIBED IN TABLE 18.3.2.1 SHALL BE

PROTECTED AS INDICATED. (LSC 18.3.2.2)

TABLE 18.3.2.1 (PARTIAL, AS APPLICABLE TO THE BUILDING'S 5TH FLOOR)

• ROOMS WITH SOILED LINEN IN VOLUME EXCEEDING 64 GAL (242 L)1 HOUR

• STORAGE ROOMS LARGER THAN 50 FT2(4.6 M2) BUT NOT EXCEEDING 100 FT2 (9.3 M2) AND STORING COMBUSTIBLE MATERIAL SEE 18.3.6.3.11.

• STORAGE ROOMS LARGER THAN 100 FT2 (9.3 M2) AND STORING COMBUSTIBLE MATERIAL 1 HOUR

• ROOMS WITH COLLECTED TRASH IN VOLUME EXCEEDING 64 GAL (242 L)1 HOUR† MINIMUM FIRE RESISTANCE RATING.

13. INTERIOR FINISH

• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 10.2 OF THE NFPA 101 TO CLASS A MATERIALS. (LSC 18.4.3.6.2)

• · CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.

• FLOORS: INTERIOR FLOOR FINISH SHALL BE CLASS I.

• FABRIC DRAPERIES, CURTAINS (EXCLUDING SHOWER CURTAINS, BUT INCLUDING CUBICLE CURTAINS), AND OTHER LOOSELY HANGING FABRICS AND FILMS

SERVING AS FURNISHINGS OR DECORATIONS IN HEALTH CARE OCCUPANCIES MUST MEET THE FLAME RESISTANCE REQUIREMENTS OF NFPA 701, STANDARD

METHODS OF FIRE TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS.

• UPHOLSTERED FURNITURE AND MATTRESSES. UPHOLSTERED FURNITURE AND MATTRESSES MUST ALSO MEET SPECIFIED REQUIREMENTS, BASED ON NFPA

260, NFPA 261, NFPA 266, 16 CFR 1632, ASTME E1537, AND ASTME E1590

14. EXTINGUISHMENTS REQUIREMENTS, PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 10. EXISTING FE/FEC SHALL REMAIN.

15. DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. EXISTING SYSTEMS SHALL REMAIN.

16. FIRE SUPPRESSION:

SPRINKLER SYSTEM: BUILDING IS REQUIRED TO BE SPRINKLED THROUGHOUT IN ACCORDANCE WITH NFPA 13. EXISTING SYSTEMS SHALL REMAIN

17. CONSTRUCTION BARRIERS CONSTRUCTED ALONG MEANS OF EGRESS SHALL BE CONSTRUCTED AND MAINTAINED PER NFPA 241.

CODE ANALYSIS - NFPA 101, INSTITUTIONAL HEALTHCARE CHAPTER 18

MEDICAL CENTER DIRECTOR,

ASSOCIATE DIRECTOR,

CHIEF OF STAFF,

AD OF PATIENT CARE SERVICES,

CHIEF OF ENGINEERING,

SAFETY OFFICER,

INFORMATION SECURITY OFFICER,

CHIEF OF POLICE,

INFECTION PREVENTION OFFICER,

CHIEF OF PSYCHIATRY,

NAGE

VA GRAND JUNCTION DESIGN ACCEPTANCE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs \s w h it c o m b .G

U

ID

O N

D E

S

IG

N \D o c u m e n ts

\1

.1

.0

V

A G ra n d

J u n c ti o n I D

IQ

Im p ro v e

P a ti e n t S a fe ty C e n tr a l

M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m

.r v t

/2

/2

:1

:5

P

M

GI000

COVER SHEET AND CODE REVIEW

GUIDON DESIGN

905 N. CAPITOL AVENUNE, SUITE 100

INDIANAPOLIS, IN 46204

317-800-6388

STEWART WHITCOMB

IMPROVE PATIENT SAFETY, 5P

GRAND JUNCTION, VAMC

575-18-106

BLDG. #1

08/24/2018 UJ STW

BID DOCUMENTS

FULLY SPRINKLERED

DEPARTMENT OF VETERAN AFFAIRS

GRAND JUNCTION, VAMC

BID DOCUMENTS

IMPROVE PATIENT SAFETY, 5P

575-18-106

SHEET LIST

SHEET NUMBER SHEET NAME

GENERAL

GI000 COVER SHEET AND CODE REVIEW

ARCHITECTURAL

AS001 ARCHITECTURAL GENERAL INFORMATION AND PHASING

AS100 ARCHITECTURAL PLANS AND DETAILS

AS200 REFLECTED CEILING PLAN AND DOOR DETAILS

Contact: Contact:

GRAND JUNCTION VETERANS HEALTH

CARE SYSTEM

GRAND JUNCTION CO.

ROJELIO CHAVEZ Jr.

CONTRACTING OFFICER'S REPRESENTATIVE

2121 NORTH AVENUE,

GRAND JUNCTION CO. 81501

p: 970-263-5016 e: Rojelio.Chavez@va.gov

OWNER

GUIDON DESIGN INC.

STEWART WHITCOMB, AIA, LEED AP BD+C

ARCHITECT, SUSTAINABILITY DIRECTOR

905 North Capitol Avenue Suite 100 Indianapolis, IN 46204 p: 317.800.6388 x 102 e: swhitcomb@guidondesign.com

ARCHITECT

AREA MAP

VICINITY MAP

VA MEDICAL CENTER

2121 NORTH AVENUE

BLDG. # 1 VA MEDICAL CENTER

PROJECT AREA, 5TH FLOOR

LIFE SAFETY OCCUPANCY COUNT

AREA SF OCC OCC FACTOR # OF OCC

TOTAL:

PROJECT

AREA (NET)

FLOOR TOTAL:

GROSS BUILDING AREA

5TH FLOOR (PROJECT AREA) SF

NO CHANGE, ETR

BUILDING TOTAL:

NO CHANGE, ETR

3800 8 STAFF 240 16

(8 UNITS) (8 VETS)

(PER UNIT)

NO CHANGE

T H

F L O O R

Revisions: Date:

UP

SECTION REFERENCE

DRAWING NUMBER

SHEET

LOCATION

DRAWING NUMBER

SHEET

LOCATION

DETAIL REFERENCE

OBJECT

REFERENCED

OBJECT

REFERENCED

X

XXXX

X

XXXX

SCALE: ??

VIEW TITLE

N

NORTH ARROW

INCANDESCENT WALL MOUNTED LIGHTING

INCANDESCENT SURFACE MOUNT LIGHTING

SURFACE MOUNTED FLUORESCENT

RECESSED FLUORESCENT

HVAC RETURN AIR GRILLE

HVAC SUPPLY DIFFUSER

PENDANT LIGHT

ACCESS PANEL

EXIT LIGHTING

S

D

SPEAKER

SMOKE DETECTOR

INCANDESCENT RECESSED LIGHTING

A 9'-0"

CEILING TAG CEILING TYPE

FINISHED CEILING HEIGHT

REFER TO CEILING LEGEND FOR MORE

INFORMATION

EXTENT OF REVISION

REVISION SET

MECH/ELEC ITEMS: EXISTING TO REMAIN, NOT ALL ETR ITEMS ARE SHOWN

REFLECTED CEILING PLAN SYMBOLS

DETAIL/DRAWING SCALE

TITLE OF DETAIL/DRAWING

DETAIL/DRAWING NUMBER

SHEET NUMBER

GENERAL CONSTRUCTION NOTES

THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®

SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION

MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL

DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,

SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES

MANAGEMENT.

THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE

CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE

NATIONAL CAD STANDARD AS GUIDES.

DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT

TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.

CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER

QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY

THE BID DUE DATE.

CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH OWNER’S

REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY

SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY, ACCESS

CONTROL, ETC.

ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN

FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT

LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK

AND ACCESS TO EXISTING UTILITIES FOR TIE IN.

DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING

BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC

MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR

VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH

THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND

THE SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,

ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION

REQUIREMENTS.

CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF

WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE

FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK

THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF

WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY

CERTAIN SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.

CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR

UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,

GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.

CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING

AND MAINTAINING SMOKE/FIRE RATINGS OF EXISTING CONSTRUCTION AS INDICATED

ON DRAWINGS. THIS INCLUDES PATCHING PENETRATIONS IN SHAFTS, WALLS, SLABS

AND ROOF. ONLY U.L. APPROVED METHODS, MATERIALS AND INSTALLATION ARE

ACCEPTABLE.

THE GENERAL CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL EXISTING

MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT WITH RESPECT TO THE

ARCHITECTURAL AND STRUCTURAL DETAILING OF SHAFTS, CHASES, CEILING

CONSTRUCTION, ETC.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT

IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW

CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION

BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED

CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY

ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR

MISSING DIMENSIONS.

DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL

ORIENTATION AND CONTEXT ONLY.

THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF

CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.

ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING FINISH, FACE OF NEW

FINISH, FACE OF MASONRY, OR COLUMN GRID LINES UNLESS NOTED OTHERWISE.

PROJECT FLOOR ELEVATION (100’-0”) IS EQUAL TO THE FINISH FLOOR SLAB OF THE

EXISTING SLAB FLOOR CONSTRUCTION UNLESS OTHERWISE NOTED.

ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.

CONTRACTOR SHALL PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED

AS “TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE

DETAIL, AREA, OR ITEM REFERENCED.

PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.

CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, STORAGE,

PROTECTION, MOUNTING, INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.

INSTALL, INSTALLED, OR INSTALLATION WORK SHALL BE OWNER FURNISHED

MATERIALS AND EQUIPMENT INSTALLED BY THE CONTRACTOR. CONTRACTOR IS

RESPONSIBLE FOR COORDINATION OF MATERIAL DELIVERY, MOUNTING,

INSTALLATION AND ROUGH IN.

FURNISHED WORK SHALL BE CONTRACTOR SUPPLIED MATERIALS AND EQUIPMENT

TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY

AND ROUGH-IN.

ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED

OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.

ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE

FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND

HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.

THE CONTRACTOR SHALL RESTRICT USE AND AVALIABILITY OF POWER ACTUATED

TOOLS, SUCH AS BUT NOT LIMITED TO; NAIL GUNS, GRINDERS, SAWS), TO ENSURE

SAFETY OF STAFF AND PATIENTS. SECURE TOOLS WHEN NOT IN USE AND DURING

TRANSPORT THROUGH PATIENT SPACE.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL

UTILITY AND BUILDING SERVICE LINES. DAMAGE TO ELECTRICAL, PLUMBING, DUCTS,

PIPES, OR OTHER UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS SHALL BE

REPAIRED AT NO COST TO THE OWNER AND AS SOON AS POSSIBLE.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING

REQUIRED DURING CONSTRUCTION.

CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION,

FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE.

ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE

REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.

IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT

DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER

QUALITY OF WORK, AS DETERMINED BY THE COR, SHALL BE PROVIDED.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

ARCHITECTURAL SYMBOLS

X

X

XXXX

SHEET LOCATION

VIEW NUMBER

X X

X

SHEET LOCATION

VIEW NUMBER

XXXX

BUILDING SECTION REFERENCE

DRAWING NUMBER

SHEET LOCATION

BUILDING X

XXXX

X

XXXX

ELEVATION REFERENCES

NEW WALL

WALL TO BE

REMOVED

EXISTING WALL TO

REMAIN

TEMPORARY IC

BARRIER WALL

CONSTRUCTION

ROOM

ROOM TAG

# PLAN NOTE

NEW DOOR

EXISTING DOOR

DEMOLISHED DOOR

REVISION TO PLAN CALLOUT

WALLS

DOOR TAG

DOORS

SWING SYMBOL IS DIAGRAMMATIC, MATCH EXISTING

SWING AND ORIENTATION.

ARCHITECTURAL ABBREVIATIONS

A/C AIR CONDITION

A/E ARCHITECT/ENGINEER

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR ADJUSTABLE

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AHJ AUTHORITY HAVING JURISDICTION

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

NOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APPD APPROVED

APROX APPROXIMATE

ARCH ARCHITECT

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION

AUTO AUTOMATIC

AUX AUXILIARY

AWI ARCHITECTURAL WOODWORKING INSTITUTE

BAT BATTEN

BKG BACKING

BLD/BLDG BUILDING

BLKG BLOCKING

BLKT BLANKET

BM BEAM OR BENCHMARK

BOT BOTTOM

BRCG BRACING

C CHANNEL OR CELSIUS

C TO C CENTER TO CENTER

CB CORNER BEAD

CC CUBIC CENTIMETER

CEM PLAS CEMENT PLASTER

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFMF COLD-FORMED METAL FRAMING

CG CORNER GUARD

CHFR CHAMFER

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNR CORNER

COL COLUMN

COMM COMMUNICATION

CORD COORDINATE

CORR CORRIDOR

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CRS COLD ROLLED STEEL

CSK COUNTER SUNK

CTG COATING

CTR CENTER

CTRL CONTROL

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DIA DIAMETER

DIAG DIAGONAL OR DIAGRAM

DIFF DIFFERENCE

DIM DIMENSION

DIR DIRECTION

IST DISTANCE

DIV DIVISION

DOC DOCUMENT

DOZ DOZEN

DN DOWN

DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE

PAR PARALLEL OR PARAPET

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON

PBD PARTICLEBOARD

PC POLYCARBONATE

PCF POUNDS PER CUBIC FOOT

PEN PENETRATE

PERP PERPENDICULAR

PL PLATE, PROPERTY LINE

PLBG PLUMBING

PLYWD PLYWOOD

PNL PANEL

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PREFIN PREFINISH

PREV PREVIOUS

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QTR QUARTER

QTY QUANTITY

R RADIUS

RA RETURN AIR

RBR RUBBER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECT RECTANGLE

REF REFERENCE

REQ REQUIRE/REQUIRED

RESIL RESILIENT

RET RETURN

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

RPM REVOLUTIONS PER MINUTE

RT RIGHT

SA SUPPLY AIR

SALV SALVAGE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID CORE

SCH SCHOOL

SCHED SCHEDULE

SCRN SCREEN

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR OR SOAP

DISPENSER

SECT SECTION

SEG SEGMENT

SEL SELECT

SF SQUARE FOOT (FEET)

SGL SINGLE

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SIM SIMILAR

SK SKETCH

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

S SOUTH

SPEC SPECIFICATION

SPKLR SPRINKLER

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STNLS STAINLESS

STOR STORAGE

STRUCT STRUCTURAL

SYNTH SYNTHETIC

SYS SYSTEM

E EAST

EA EACH

EFF EFFICIENCY

EL ELEVATION

ELEC ELECTRIC

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION AGENCY

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL OR EQUALLY SPACED

EQUIP EQUIPMENT

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

ETR EXISTING TO REMAIN

ETS EXPOSE TO STRUCTURE

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FCTY FACTORY

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF&E FURNITURE, FIXTURE, AND EQUIPMENT

FH FLAT HEAD OR FLAT HEAD SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIL FILLET

FIN FINISH

FIXT FIXTURE

FLG FLOORING

FLR FLOOR

FO FINISHED OPENING

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FR FIRE RATING, FIRE RESISTANT, OR FRAME

FRMG FRAMING

FS FEDERAL SPECIFICATION

FT FEET OR FOOT

FURG FURRING

FURN FURNISH OR FURNITURE

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GDR GUARD RAIL

GL GLASS

GLU LAM GLUED LAMINATED WOOD

GRTG GRATING

GSM GALVANIZED SHEET METAL

GT GROUT

GUAR GUARANTEE

GYP GYPSUM

H HIGH

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HGR HANGER

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR CONDITIONING

HW HOT WATER

I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTL INTERNATIONAL

JAN JANITOR

J-BOX JUNCTION BOX

JT JOINT

KD KILN DRIED OR KNOCKED DOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

L ANGLE

LAM LAMINATE

LAM GL LAMINATED GLASS

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE OR LEFT HAND REVERSE

LIN LINEAR

LIQ LIQUID

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MAX MAXIMUM

MCB METAL CORNER BEAD

MD METAL DECK

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL OR MEDIUM

MEMO MEMORANDUM

MFD MANUFACTURED

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE OR MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

mm MILLIMETER

MO MASONRY OPENING OR MOTOR OPERATED

MOD MODEL, MODIFY OR MODULE

MTD MOUNTED

MTL METAL

N NORTH

NA NOT APPLICABLE

NAT NATURAL

NATL NATIONAL

NEG NEGATIVE

NEUT NEUTRAL

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPT OPTIONAL

OR OUTSIDE RADIUS

OUT OUTLET

OZ OUNCE

T TREAD

TA TOILET ACCESSORY

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TCA TILE COUNCIL OF AMERICA

TD TOWEL DISPENSER

TECH TECHNICAL

TEMP TEMPERATURE OR TEMPORARY

THD THREAD

THERM THERMAL

THK THICKNESS

TMPD TEMPERED

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TRTD TREATED

TS TENSILE STRENGTH OR TUBE STEEL

TSTAT THERMOSTAT

TYP TYPICAL

U HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UL UNDERWRITERS LABORATORIES

UNFIN UNFINISH

UNO UNLESS NOTE OTHERWISE

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VAR VARIES

VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

W/ WITH

W/O WITHOUT

WBL WOOD BLOCKING

WC WALL COVERING OR WATER CLOSET

WD WOOD

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WIN WINDOW

M WIRE MESH

WT WEIGHT

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)

YD YARD

YR YEAR

TEMPORARY MEASURES AND PHASING LEGEND

TEMPORARY WALLS. SEE PLAN AND

PLAN NOTES

TEMPORARY CONSTRUCTION ACCESS

AND DUST CONTROL DOORS

PROJECT BOUNDARY

BEYOND PROJECT BOUNDARY

PROJECT PHASE A WORK

PROJECT PHASE B WORK

PROJECT PHASE C WORK

PROJECT PHASE D WORK

PROJECT WORK UNASSIGNED TO ANY

SPECIFIC PHASE4

INFECTION CONTROL PLAN NOTES

INFECTION CONTROL PROJECT INFORMATION

CONSTRUCTION ACTIVITY - FIRE RISK: Type C

PATIENT RISK GROUP: HIGH RISK

CLASS OF PRECAUTION MATRIX: III/IV

PROVIDE TEMPORARY MEASURE IN ADDITION TO EXISTING SECURITY DOOR

TO PROVIDE INFECTION CONTROL. REFER TO SPECIFICATION DIV 01.

PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR WITH

ACCESS CONTROL LOCK AND AIR FILTRATION W/ NEGATIVE RESSURE REFER

TO SPECIFICATIONS AND COORDINATE WITH COR.

PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION

WITH AIR FILTRATION AND NEGATIVE RESSURE. REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

PROVIDE TEMPORARY INFECTION CONTROL PLASTIC BARRIER WALL

CONSTRUCTION WITH AIR FILTRATION AND NEGATIVE RESSURE. REFER TO

SPECIFICATION FOR ADDITIONAL INFORMATION.

REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED

BY CLASS IN SPECIFICATION 01 35 26 AND ADDITIONAL INFORMATION.

REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE

FOR ADDITIONAL INFORMATION.

PROJECT SHALL BE COMPLETED IN SIX (6) PHASES, INCLUDING MOBILIZATION

AND CLOSE/OUT.

COORDINATE FULL SCOPE OF WORK WITH EXISTING CONDITIONS AND FIELD

VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE

CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE

PROJECT BOUNDARY.

COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER

WALL CONSTRUCTION, NEGATIVE AIR PRESSURE AND FILTRATION, AND

INFECTION CONTROL (IC) MEASURES WITH COR AND PATIENT SAFETY/

INFECTION CONTROL REPRESENTATIVE. TEMPORARY IC BARRIER WALL

CONSTRUCTION LOCATIONS IN DRAWINGS ARE APPROXIMATE. CONTRACTOR

SHALL PROVIDE DRAWING TO COR AND PATIENT SAFETY/ INFECTION

CONTROL REPRESENTATIVE ONCE ICRA PROTOCOLS AND PLAN IS

APPROVED.

SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR

AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING

INFORMATION FOR ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED

CMP SCHEDULE FOR WORK ALSO REQUIRED ABOVE AND BELOW THE FLOOR

PLATE OF THE PROJECT BOUNDARY.

EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED

DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF

OPERATION.

WORK REQUIRING VIBRATION, LOAD NOISE, OR IMPACT NOISE SHALL TAKE

PLACE BETWEEN THE HOURS OF 10:00 AM AND 3:00 PM. EVERY EFFORT

SHALL BE MADE TO KEEP NOISE AND VIBRATION TO A MINIMUM.

COORDINATE WITH COR

PROVIDE A 24"X36" STICKY WALK OFF MAT AND HAND SANITIZER AT EACH

TEMPORARY DOOR LOCATION. MAT SHALL BE REPLACED OR CLEANED AS

NECESSARY

PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH

TEMPORARY DOOR LOCATION. MATERIALS AND METHODS SHALL BE

APPROVED BY VA STAFF

CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,

MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE

LIQUIDS UP TO 30 GALLONS.

ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH

4 MIL. POLY SHEET.

ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT

BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED

ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED

WITH A LID. DUMPSTER SHALL BE PROVIDED BY CONTRACTOR

ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY

STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE

MATERIALS SHALL NOT BE STORED IN THE FACILITY.

PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE

PROJECT BOUNDARY.

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

INFECTION CONTROL GENERAL NOTES

PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT

CONSTRUCTION, EXCEPT PHASE A, B, C, AND D.

WORK IN THIS AREA CAN BE COMPLETED AT ANY PHASE, WITH INDICATED

INFECTION CONTROL AND SAFETY MEASURES, REFERENCE SPECIFICATIONS.,

COORDINATE WITH COR.

WORK SHALL NOT BE COMPLETED DURING NIGHT SHIFTS, 5:00 PM TO 5:00 AM,

WITHOUT AUTHORIZATION BY COR. ALL WORK TO BE COMPLETED AND OPEN

FOR VA MEDICAL CENTER USE AT THE END OF EACH PHASE.

REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURATION

FOR EACH PHASE AND AREA OF WORK.

PHASE 1 COMPLETION SHALL BE 'PUNCHED' BY A/E AND VA TO ESTABLISH

FINISH AND COMPLETION STANDARDS FOR THE PROJECT.

PHASING PLAN NOTES #

A.

B.

C.

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

STAIR

CONFERENCE

RM

CORRIDOR

SECURE

ENTRY

NURSE

STATION

ISOLATION

RM

VESTIBULE

5010B

TOILET RM

5010A

ISOLATION

RM

DAY RM

PATIENT RM

CORRIDOR

STAIR

ELEC RM

5008A

JAN RM

5008B

PATIENT

STORAGE

2 2

EXIT

EXIT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs \s w h it c o m b .G

U

ID

O N

D E

S

IG

N \D o c u m e n ts

\1

.1

.0

V

A G ra n d

J u n c ti o n I D

IQ

Im p ro v e

P a ti e n t S a fe ty C e n tr a l

M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m

.r v t

/2

/2

:1

:5

P

M

AS001

ARCHITECTURAL GENERAL

INFORMATION AND PHASINGGUIDON DESIGN

905 N. CAPITOL AVENUNE, SUITE 100

INDIANAPOLIS, IN 46204

317-800-6388

STEWART WHITCOMB

IMPROVE PATIENT SAFETY, 5P

GRAND JUNCTION, VAMC

575-18-106

BLDG. #1

08/24/2018 UJ STW

BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AS001

1 5TH FLOOR PHASING PLAN

UP

UP

ARCHITECTURAL PLAN NOTES

PROVIDE PSYCHIATRIC INTERIOR RETROFIT WINDOW AT INTERIOR SIDE OF

EXISTING WINDOW FRAME, VERIFY EXISTING CONDITIONS AND COORDINATE

WITH STUD FRAMING FOR MOUNTING SURFACE. FRAME IS APPROXIMATELY 48"

W AND 60" TALL, SEE SCHEDULE AND TYPICAL ELEVATIONS ON AS200.

COORDINATE W/ NEW BULKHEAD CONSTRUCTION.

REFERENCE DEMO. PLANS FOR REMOVED ACCESS PANEL/HATCH IN WALL.

PROVIDE HEAVY DUTY ACCESS PANEL TO MATCH EXISTING SIZE AND

ORIENTATION. HARDWARE SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN

CYLINDER. REFERENCE ALTERNATE B: OMIT ACCESS PANEL/HATCH

REPLACEMENT WORK.

PROVIDE DOOR LEAF/SLAB TO MATCH EXISTING, APPROX. 3" LESS THAN

FRAME TO ACCOMMODATE CONTINUOUS HINGE SPECIFIED WITH EXISTING

ANTI-BARRICADE FRAME. INSTALL SALVAGED HARDWARE, EXCEPT PROVIDE

CONTINUOUS HINGE.

REFERENCE DEMO PLANS FOR REMOVED HINGES. PROVIDE DOOR LEAF/SLAB

APPROX. 3" LESS THAN FRAME TO ACCOMMODATE CONTINUOUS HINGE AS

SPECIFIED WITH EXISTING ANTI-BARRICADE FRAME. INSTALL SALVAGED

HARDWARE AND ADJUSTED FOR HINGE AND POSITION. REFERENCE

ALTERNATE A: OMIT DOOR AND DOOR HARDWARE REPLACEMENT WORK.

PROVIDE PROTECTION FOR WALL MURAL WITH SHEET OR BOARD PRODUCT

MOUNTED INPLACE THROUGHOUT PHASE. REMOVE ANY HANGERS OR

FASTENERS FROM THE AREA PATCH/REPAIR AND PAINT SURROUNDING

FINISHES TO LIKE-NEW CONDITION

WORK PER ALTERNATE C: OMIT DOOR AND WINDOW WORK FROM SELECTED

SPACES.

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

STAIR

CONFERENCE

RM

CORRIDOR

SECURE

ENTRY

NURSE

STATION

ISOLATION

RM

VESTIBULE

5010B

TOILET RM

5010A

ISOLATION

RM

DAY RM

PATIENT RM

CORRIDOR

STAIR

ELEC RM

5008A

JAN RM

5008B

PATIENT

STORAGE

1.

2.

1. 1. 1.

1. 1. 1.

3.4.4.4.

4.

4.4.4.4.

1.

2.

1.

2.

1.

2.

1.

2.

1.

2.

2. 2. 2.

33B33A13141516

17 18 19 20

21 22 23B 23A

5.

5.

5.5.5.

5.

5.5.5.

2.

2.

5.

5.

6.

6.

2.

DEMOLITION GENERAL NOTES

COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND

REPAIR NECESSARY TO COMPLETE THE WORK AND REMODEL

CONSTRUCTION SHALL BE PROVIDED. CONTRACTOR SHALL REMOVE

EXISTING IMPROVEMENTS WHETHER OR NOT SPECIFICALLY INDICATED ON

THE DRAWINGS TO FACILITATE THE COMPLETION OF ALL REQUIRED WORK.

CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL QUANTITIES AND ITEMS

REQUIRED TO BE REMOVED.

REFER TO ARCHITECTURAL SYMBOLS ON SHEET AS001 FOR DEMOLITION

SYSTEMS AND DRAWING NOMENCLATURE.

EXISTING STRUCTURE WITHIN THE PROJECT BOUNDARY SHALL REMAIN

UNLESS OTHERWISE NOTED.

SURFACES TO BE CUT AND CONDITIONS UNDER WHICH CUTTING IS TO BE

PREFORMED SHALL BE REVIEWED BY CONTRACTOR PRIOR TO CUTTING TO

VERIFY NO UNSAFE OF UNSATISFACTORY CONDITIONS EXIST. COORDINATE

WITH OCCUPANTS, PATIENT CARE, AND NOTIFY COR/VA OF ALL POWERED

EQUIPMENT TO BE USED TO FACILITATE NOISE/DISTURBANCE DISCUSSIONS.

SUCH CONDITIONS SHALL BE RECTIFIED BEFORE WORK MAY PROCEED.

EXTENTS OF DEMOLITION SHALL BE COORDINATE WITH THE ARCHITECTURAL

FLOOR PLAN AND DETAIL DRAWINGS.

DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE

APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL SCOPE OF WORK TO

BE REMOVED OR TEMPORARILY REMOVED TO ACCOMMODATE NEW

CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF

NEW CONSTRUCTION TO PROVIDE ADEQUATE AREA FOR THIS WORK.

MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER TO RECEIVE

NEW FINISHES. DEMOLITION SHOULD BE PERFORMED IN A MANNER SUCH

THAT THE CONTRACTOR CAN SEAMLESSLY PATCH NEW WORK TO BE

SMOOTH AND UNDETECTABLE.

ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, DAMAGED AND

BROKEN GYPSUM BOARD CEILINGS SHALL BE PATCHED AND PAINTED TO

SEAMLESSLY MATCH EXISTING CEILING COLOR FOLLOWING ABOVE CEILING

DEMOLITION ACTIVITY. THIS SHALL INCLUDE REPAIR TO THE CEILING GRID,

SUSPENSION SYSTEM, GYPSUM BOARD, FINISH AND ALL ASSOCIATED

ASSEMBLIES AS WELL AS THE REPLACEMENT OF DAMAGED CEILING PANELS,

WITHIN AND BEYOND PROJECT LIMITS.

COORDINATE FULL SCOPE OF DEMOLITION WORK WITH ENGINEERING AND

VENDOR DRAWINGS.

EXISTING FLOOR FINISH AND WALL MURALS ARE TO REMAIN. EMPLOY ALL

NECESSARY MEANS AND METHODS TO PROTECT THE FLOOR FINISH, WALL

MURALS IN ROOMS AND CORRIDOR FROM DAMAGE, SCRATCHES, CRACKING

OR OTHER DEGRADATION. CONTRACTOR SHALL REPLACE FLOORING FINISH

OR ANY MURAL DAMAGED THROUGH THE COURSE OF THE WORK.

A

B

C

D

E

F

G

H

I

J

DEMOLITION PLAN NOTES

REMOVE HEAD, JAB AND SILL TRIM AND FINISH FROM WINDOW AND WALL.

REMOVE 3 5/8" STUD FRAMING AT SILL, JAMB AND HEAD OF WINDOW.

PREPARE FOR REPLACEMENT FRAMING AS INDICATED IN ARCHITECTURAL

DETAILS AND SPECIFICATIONS. PREPARE ADJACENT AREA TO RECEIVE FINISH

TO MATCH EXISTING.

REFERENCE REFLECTED CEILING PLAN FOR ACCESS HATCH TO BE REMOVED

IN THIS AREA.

REMOVE STAINLESS STEEL ACCESS PANEL FROM CORRIDOR WALL, PREPARE

FOR REPLACEMENT HEAVY DUTY STAINLESS STEEL HATCH. REFERENCE

ALTERNATE B: OMIT ACCESS PANEL/HATCH REPLACEMENT WORK.

REMOVE AND SALVAGE DOORS LEAVES AND HARDWARE. DOOR FRAME TO

REMAIN IN PLACE. SALVAGE LEAVES TO OWNER AND REMOVE PIVOT-SET

RECEIVER OR BRACKET FROM DOOR. REMOVE PIVOT-SET PIN/SHAFT, CUT OR

GRIND. PROTECT OR REPLACE EXISTING FLOORING. PIVOT SET ANCHOR AND

CONCEALED COMPONENTS ARE TO REMAIN WITHIN FLOOR. DO NOT

DEMOLISH FLOOR DECK OR FINISH. REFERENCE ALTERNATE A: OMIT DOOR

AND DOOR HARDWARE REPLACEMENT WORK.

REMOVE AND SALVAGE DOORS AND HARDWARE, STORE DOOR AS DIRECTED

BY VA COR. DOOR FRAME TO REMAIN IN PLACE. REMOVE PIVOT-SET

PIN/SHAFT, CUT OR GRIND. PROTECT OR REPLACE EXISTING FLOORING.

PIVOT SET ANCHOR AND CONCEALED COMPONENTS ARE TO REMAIN WITHIN

FLOOR. DO NOT DEMOLISH FLOOR DECK OR FINISH.

WORK PER ALTERNATE C: OMIT DOOR MODIFICATIONS AND WINDOW FROM

SELECTED SPACES.

REMOVE AND SALVAGE DOORS HARDWARE. REMOVE PIVOT-SET RECEIVER

OR BRACKET FROM DOOR. PROTECT PIVOT-SET PIN/SHAFT AND EXISTING

FLOORING.

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

STAIR

CONFERENCE

RM

CORRIDOR

SECURE

ENTRY

NURSE

STATION

ISOLATION

RM

VESTIBULE

5010B

TOILET RM

5010A

ISOLATION

RM

DAY RM

PATIENT RM

CORRIDOR

STAIR

ELEC RM

5008A

JAN RM

5008B

PATIENT

STORAGE

1.

2.

1. 1. 1.

1.

1.

1.

3.4.

4.

4.

1.

2.

1.

2.

1.

2.

1.

2.

1.

2.

2. 2.

2.

2.

4.

4. 4.3.

6.

6.

3.

7.

5020E

EXISTING WINDOW, TO

REMAIN

REPAIR GYP BOARD

BULKHEAD W/ IMPACT

RESISTANT GYP.

PSYCHIATRIC RETROFIT

INTERIOR WINDOW SILL AS

SPECIFIED.

REPAIR GYP BOARD WALL W/

IMPACT RESISTANT GYP.

EXISTING WINDOW, TO

REMAIN

PSYCHIATRIC RETROFIT

INTERIOR WINDOW JAMB AS

SPECIFIED.

PSYCHIATRIC RETROFIT

INTERIOR WINDOW HEAD AS

SPECIFIED.

PROVIDE 12 GA. 3 5/8" DOUBLE

KING STUD CORNERS W/

BLOCKING.

TYPICAL

A S

S C

H E

D U

LE

D

AS SCHEDULED

PROVIDE SWING FOR EASE

OF MAINTENANCE ACCESS,

CORD. W/ ADJACENT WALLS

AND JAMB CONDITION.

WINDOW SHALL RESIST 2000

FT-LBS OF HUMAN IMPACT

ENERGY

1/4" MAXIMUM EDGE

PROFILE.

SEAL TO GYP BOARD WITH

TAMPER RESISTANT

SEALANT.

EXISTING WINDOW,

TO REMAIN

REMOVE GYP BOARD AND STUD

FROM WALL; ACCOMMODATE

NEW CONSTRUCTION

REMOVE GYP BOARD AND STUD

FROM WALL; ACCOMMODATE

NEW CONSTRUCTION

REMOVE GYP BOARD AND STUD

FROM BULKHEAD;

ACCOMMODATE NEW

CONSTRUCTION

M A

T C

H E

X

IS

T

IN

G S

IL

L

E X

IS

T

IN

G

W

IN

D O

W O

P E

N

IN

G

ROUGH WIDTH, SEE SCHEDULE

PROVIDE 12 GA. 3 5/8" DOUBLE KING STUD

CORNERS W/ BLOCKING

PROVIDE 12 GA. 3 5/8" STUD HEADER W/

BLOCKING AND CHANNEL

PROVIDE 5/8" IMPACT RESISTANT GYP BOARD, TYP.

PROVIDE 12 GA. DOUBLE STUD SILL W/ CHANNEL AND

BLOCKING TO EXTERIOR CMU WALL @ 12" O.C.

PROVIDE 12 GA. 3 5/8" STUDS @ MAX 16" O.C.

W/ TRACK TO STRUCTURAL DECK BELOW

PROVIDE 12 GA. 3 5/8" STUDS @ MAX 16" O.C.

RESTORE WALL BOARD AND CEILING WITH

BLOCKING AND IMPACT RESISTANT GYP BOARD, TYP.

4 7/8" BULKHEAD W/ 3 5/8" STUDS AND 5/8 IMPACT RESISTANT

GYP ON EACH SIDE, COORDINATE W/ PSYCHIATRIC WINDOW

SWING AND CEILING HEIGHT.

S E

C U

R

IT

Y W

IN

D

O W

R O

U G

H H

E

IG

H T

ANCHOR STUDS TO STRUCTURAL DECK

ABOVE

PROVIDE 12 GA. 3 5/8" STUD BLOCKING @ MAX 16" O.C.

TO EXTERIOR CMU WALL, TYP.

ALTERNATE BID ITEMS

ALTERNATE NO. A : OMIT DOOR AND DOOR HARDWARE REPLACEMENT WORK.

DO NOT PROVIDE LABOR, MATERIALS, COORDINATION OR OVERSIGHT FOR

DOOR REMOVAL, SALVAGE, AND DOOR MODIFICATION TO UPGRADE HINGES

TO CONTINUOUS HINGE AT PATIENT ROOMS

ALTERNATE NO. B: OMIT ACCESS PANEL/HATCH REPLACEMENT WORK. DO NOT

PROVIDE LABOR, MATERIALS, COORDINATION OR OVERSIGHT FOR STAINLESS

STEEL SECURITY HATCH REPLACEMENT, AND ASSOCIATED SELECTIVE

DEMOLITION AND INFECTION CONTROL IN CORRIDOR 5032, WALLS AND

CEILING HATCHES.

ALTERNATE NO. C: OMIT DOOR MODIFICATIONS AND WINDOW FROM SELECTED

SPACES. DO NOT PROVIDE LABOR, MATERIALS, COORDINATION OR

OVERSIGHT FOR SELECTIVE DEMOLITION, INTERIOR WINDOWS FOR ROOMS

5021, 5022, 5023, CONTINUOUS HINGES FOR 5010A, 5011 AND 5012, AND ANY

ASSOCIATED INFECTION CONTROL.

NOTE: ALL PATIENT ROOM CEILING HATCHES ARE BASE BID WORK

REPLACEMENT OF DOOR 5020 AND HARDWARE INSTALLATION IS

BASE BID WORK.

SEE SPECIFICATIONS 010000 FOR ADDITIONAL INFORMATION ON BID

ITEMS AND ALTERNATES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs \s w h it c o m b .G

U

ID

O N

D E

S

IG

N \D o c u m e n ts

\1

.1

.0

V

A G ra n d

J u n c ti o n I D

IQ

Im p ro v e

P a ti e n t S a fe ty C e n tr a l

M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m

.r v t

/2

/2

:1

:5

P

M

AS100

ARCHITECTURAL PLANS AND

DETAILSGUIDON DESIGN

905 N. CAPITOL AVENUNE, SUITE 100

INDIANAPOLIS, IN 46204

317-800-6388

STEWART WHITCOMB

IMPROVE PATIENT SAFETY, 5P

GRAND JUNCTION, VAMC

575-18-106

BLDG. #1

08/24/2018 UJ STW

BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AS100

3 5TH FLOOR BEHAVIORAL HEALTH UNIT

SCALE: 1/8" = 1'-0"AS100

1 5TH FLOOR DEMOLITION PLAN BEHAVIORAL HEALTH UNIT

SCALE: 1" = 1'-0"AS100

4 TYPICAL HEAD, JAMB AND SILL

SCALE: 1/4" = 1'-0"AS100

6 WINDOW ELEVATION

SCALE: 1/2" = 1'-0"AS100

2 TYPICAL SECTION, DEMOLITION AT WINDOW

SCALE: 1/2" = 1'-0"AS100

5 WINDOW FRAMING ELEVATION

WINDOW SCHEDULE

MARK TYPE OPERATION

DESIGN

HEIGHT*

DESIGN

WIDTH* SILL HEIGHT BASSIS OF DESIGN Comments

13 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW LEFT JAMB. MODIFY WALL.

14 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW LEFT JAMB. MODIFY WALL.

15 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

16 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

17 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

18 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/4" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW RIGHT JAMB, MODIFY WALL

19 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

20 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 5" 3' - 11" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

21 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC REMOVE AND REINSTALL CURTAINS, SEE ALT C

22 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C

23A PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 4 5/8" 4' - 0 1/4" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C

23B PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 4 1/2" 4' - 1" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C

33A PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

33B PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC

NOTES: DESIGN HEIGHT AND WIDTH HAVE BEEN MADE WITH ASSUMPTIONS ABOUT HIDDEN CONDITIONS WITHIN WALL. CONTRACTOR TO FIELD VERIFY AND COORDINATE HEIGHT AND WIDTH.

ALL GLAZING SHALL BE 1/2" COATED POLYCARBONATE, AS SPECIFIED

PROVIDE EACH WINDOW WITH KEY LOCKING KNOB FOR OPERATION, LIGATURE FREE KNOB FOR BLIND CONTROL, EXISTING FINISH SCHEDULE

FINISH MARK FINISH MANUFACTURER PATTERN/STYLE COLOR SIZES COMMENTS

HCF-1 HIGH PERFORMANCE COATED FLOOR -- SLIP-RESISTANT TEXTURE BEIGE / TAUPE 3 COAT FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.

ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG FINE FISSURED WHITE 2X4 PRODUCT NO. 1763

ACT-X ACOUSTICAL CEILING TILE MATCH EXISTING -- WHITE 2X4 --

PL-1 PLASTIC LAMINATE WILSONART 4845-60 SATIN TWILIGHT ZEPHYR N/A COUNTER TOP SPLASH AND TRIM. NOT USED IN PROJECT

SCOPE

PL-2 PLASTIC LAMINATE WILSONART 10776-60 SATIN KENSINGTON MAPLE N/A CABINET FACES AND BASE

CPT-1 CARPET TILE MANNINGTON 8206 - EXPEDITION MATCH EXISTING 2x2 NOT USED IN PROJECT SCOPE

CPT-2 CARPET TILE -- MATCH EXISTING MATCH EXISTING 2x2 NOT USED IN PROJECT SCOPE

RS-1 RESILIENT SHEET VINYL WOOD GRAIN, SIM. 4" WOOD LIGHT BROWN WOOD ROLL FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.

TS-1 TRANSITION STRIP METAL SCHLUTER SCHLUTER RENO-TK STAINLESS STEEL CERAMIC TO CARPET, MAY NOT OCCUR IN PROJECT

TS-2 TRANSITION STRIP METAL SCHLUTER SCHLUTER RENO-U STAINLESS STEEL CERAMIC TO RESILIENT FLOOR, MAY NOT OCCUR IN PROJECT

TS-3 TRANSITION STRIP RESILIENT JOHNSONITE MATCH 80 MATCH ADJACENT BASE RESILENT SHEET VINYL TO HPC OR CARPET

RB-1 RESILIENT BASE JOHNSONITE 80 FAWN 6" COVE BASE, COIL LENGTH, MAY NOT OCCUR IN PROJECT

RB-2 RESILENT BASE ROPPE P130 BUCKSKIN 6" EXISTING COVE BASE, MAY NOT OCCUR IN PROJECT

PT-1 PAINT #1 EXISTING, SHERWIN WILLIAMS SW 6112 BISCUIT - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD

PT-2 PAINT #2 EXISTING, SHERWIN WILLIAMS SW 6385 DOVER WHITE - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD

PT-3 PAINT #3 EXISTING, SHERWIN WILLIAMS SW 6113 INTERACTIVE CREAM - SEMI-GLOSS N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD

PT-4 PAINT #4 EXISTING, SHERWIN WILLIAMS - MATCH EXISTING N/A FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.

PT-5 PAINT #5 EXISTING, SHERWIN WILLIAMS SW 6165 CONNECTED GRAY - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD

PT-X PAINT #0 EXISTING, SHERWIN WILLIAMS - MATCH EXISTING N/A FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME FLOOR BASE WALLS CLG FIN. COMMENTS

5008A ELEC RM ETR ETR ETR ETR NO WORK IN THIS SPACE

5008B JAN RM ETR ETR ETR ETR NO WORK IN THIS SPACE

5010A TOILET RM ETR ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK

5010B VESTIBULE ETR, 1. RS-1 ETR, RS-1 ETR ETR REFERENCE DOOR SCHEDULE FOR WORK

5011 ISOLATION RM ETR, 1. RS-1 ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK

5012 ISOLATION RM ETR, 1. RS-1 ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK

5013 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5014 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5015 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5016 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5017 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5018 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5019 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5020 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5021 CONFERENCE RM ETR ETR PT-X, 2. PROTECT EXISTING FINISHES AND FURNITURE

5022 CORRIDOR ETR ETR PT-X, 2. PROTECT EXISTING FINISHES

5023 SECURE ENTRY ETR ETR PT-X, 2. PROTECT EXISTING FINISHES

5028 STAIR ETR ETR ETR ETR NO WORK IN THIS SPACE

5029 STAIR ETR ETR ETR ETR NO WORK IN THIS SPACE

5030 PATIENT STORAGE ETR ETR ETR ETR NO WORK, NO ACCESS TO THIS SPACE

5031 NURSE STATION ETR ETR ETR ETR NO WORK IN THIS SPACE

5032 CORRIDOR ETR, 1. RS-1 ETR, RS-1 PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES

5033 DAY RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING FINISHES AND FURNITURE

NOTES 1: PROTECT FLOOR THROUGHOUT WORK. REPLACE ANY AREAS DAMAGED BY CONTRACTOR AT NO COST TO VA.

2: PROVIDE PAINT AND SEALANT AT HATCHES REPLACED IN THE WORK.

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

STAIR

PATIENT RM

PATIENT RM

5015 PATIENT RM

PATIENT RM

5013 DAY RM

ISOLATION

RM

VESTIBULE

5010B

TOILET RM

5010A

ISOLATION

RM

NURSE

STATION

SECURE

ENTRY

CORRIDOR

CORRIDOR

CONFERENCE

RM

STAIR

1 1

REFLECTED CEILING PLAN GENERAL NOTES

REFLECTED CEILING PLAN NOTES

1.

2.

REMOVE 24" X 24" ACCESS PANEL/HATCH IN CEILING. PROVIDE HEAVY DUTY

ACCESS PANEL TO MATCH EXISTING SIZE AND ORIENTATION. HARDWARE

SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN CYLINDER.

REMOVE 18" X 18" ACCESS PANEL/HATCH IN CEILING. PROVIDE HEAVY DUTY

ACCESS PANEL TO MATCH EXISTING SIZE AND ORIENTATION. HARDWARE

SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN CYLINDER.

A

B

C

D

E

F

THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL BE COORDINATED WITH

THE EXISTING LAYOUT OF ALL CEILING ELEMENTS, HEIGHTS AND/OR

PENETRATIONS. COORDINATION OF THE HATCH INSTALLATION WITH ACCESS

CLEARANCE, MAINTENANCE WORK, AND FUNCTION OF EXISTING ABOVE

CEILING AND IN WALL EQUIPMENT, PANELS, AND OTHER ELEMENTS IN THE

FIELD.

THE CONTRACTOR IS TO VERIFY FIELD CONDITIONS, HATCH SWING/HINGE

DIRECTION, AND REPORT ANY DISCREPANCIES TO ARCHITECT AND COR.

CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)

SHALL BE PROTECTED THROUGHOUT CONSTRUCTION

DRYWALL CEILINGS SHALL BE PATCHED, PREPPED AND NEW FINISH APPLIED

TO MATCH EXISTING. ALL CEILINGS IN PROJECT AREA ARE DRYWALL/HARD LID.

REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON

GYPSUM BOARD PAINT FINISH.

ALL EXPOSED FASTENERS SHALL BE TAMPER RESISTANT THAT CANNOT BE

TURNED BY MAKESHIFT TOOLS.

2"

FRAMING STUD HEADER

RESCUE DOOR HOLLOW METAL DOOR

FRAME

SEALANT - BOTH SIDES

WALL TYPE, SEE PLANS

RESCUE STOP/ STRIKE

CORRIDOR

SIDE

TOILET

SIDE

FOR REFERENCE ONLY

2"

DOUBLE STUD FRAMING

RESCUE DOOR HOLLOW METAL

DOOR FRAME

SEALANT - BOTH SIDES

WALL TYPE, SEE PLANS

RESCUE STOP/ STRIKE

TOILET SIDE

CORRIDOR SIDE

FOR REFERENCE ONLY

D-1

A S

S C

H E

D U

LE

D

VERIFY WITH HINGE

3" LESS THAN EXISTING FRAME

F-1

ETR 2" TYP

RESCUE FRAME

E T

R

DOOR SCHEDULE COMMENTS

A

B

C

EXISTING ANTI-BARRIER HARDWARE AND FRAME TO REMAIN. PROTECT

FINISH. COORDINATE WITH NEW WORK.

TEMPORARY INFECTION CONTROL DOOR. SEE SHEET AS001 AND

SPECIFICATIONS FOR MORE INFORMATION. DOOR AND HARDWARE ARE THE

RESPONSIBILITY OF THE CONTRACTOR.

REFER TO DETAILS INDICATED FOR JAMB, AND SPECIFICATIONS FOR DOOR

HARDWARE. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION.

DOOR AND FRAME GENERAL NOTES

CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL HARDWARE

REQUIREMENTS BETWEEN HARDWARE SUPPLIES,…