CODE ANALYSIS LEGEND
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE (ETR)
FIRE EXTINGUISHER CABINET (ETR)
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE (ETR)
EXISTING EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND
REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.
ICC, INTERNATIONAL BUILDING CODES, 2018 EDITION (IBC)
FPA 80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS, 2016 EDITION
NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2015 EDITION
FPA 101, LIFE SAFETY CODE, 2015 EDITION
NFPA 220, STANDARD TYPES OF BUILDING CONSTRUCTION, 2015 EDITION.
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
EXISTING CONDITIONS MAYBE "GRANDFATHERED" INTO CURRENT CODES, GOVERNING
CODES ARE DIRECTLY APPLICABLE TO WORK THAT SHALL BE PROVIDED BY THIS
CONTRACT. CONTACT THE COR AND A/E FOR CLARIFICATIONS ON CODE/GUIDELINE
INTERPRETATIONS.
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD
STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
NAPHS DESIGN GUIDE FOR THE BUILT ENVIRONMENT OF BEHAVIORAL HEALTH
FACILITIES
VA SPACE PLANNING CRITERIA, PG-18-9, CHAPTER 110
VA MENTAL HEALTH FACILITIES DESIGN GUIDE, DECEMBER 2010 (REV. 08/01/2014)
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
ARCHITECTURAL, AUGUST 1, 2014
NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010
FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015
INTERIOR DESIGN, MAY 2008
VA DESIGN MANUALS PG-18-10:
GOVERNING CODES:
REFERENCE ARCHITECTURAL PLANS AND ROOM SCHEDULE FOR PROJECT LAYOUT AND SCOPE
EXISTING ITEMS UNCHANGED ARE SHOWN HALF-TONE/GRAY
CODE CRITERIA
GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101 (LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD
PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
NOTES:
CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
CODE REVIEW
THE 2018 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS.
FOR FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES, THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE HAS BEEN
USED.
PROJECT SCOPE
THE PROJECT SCOPE INCLUDES THE EXISTING BUILDING'S EAST WING ON FIFTH FLOOR, WHICH WILL BE MODIFIED TO IMPROVE THE PATIENT ENVIRONMENT, SAFETY AND PRIVACY. THE USE AND OCCUPANCY REMAIN UNCHANGED. THE OCCUPANCY IS A GROUP I-2, INSTITUTIONAL, INPATIENT HEALTHCARE.
CODE ANALYSIS
THE EXISTING BUILDING'S EAST WING ON FIFTH FLOOR IS UNDERGOING A REMODEL TO IMPROVE THE PATIENT ENVIRONMENT, SAFETY(IN REDUCING RISK OF SELF- HARM) AND PRIVACY. THE OCCUPANCY CLASSIFICATION AND USE TYPES AND COUNTS REMAIN UNCHANGED. THE OCCUPANCY IS A GROUP I-2, INSTITUTIONAL, HOSPITAL
INPATIENT HEALTHCARE.
THE CONSTRUCTION TYPE IS DETERMINED BASED UPON THE ALLOWABLE AREA AND HEIGHT REQUIREMENTS OF CHAPTER 5 OF THE 2018 IBC. CONSTRUCTION TYPE AND MATERIALS SHALL BE PER CHAPTER 6 OF THE IBC FOR TYPE I-A CONSTRUCTION AND LSC 1 (332) CONSTRUCTION AS FOLLOWS:
1. OCCUPANCY TYPE: I-2 INSTITUTIONAL, IBC CHAPTER 3/LSC CHAPTER 18 HEALTHCARE
2. CONSTRUCTION TYPE: I-A (IBC CHAPTER 5)
3. FIRE RESISTIVE RATINGS TYPE 1-A CONSTRUCTION, CHAPTER 6 IBC/NFPA 101:
STRUCTURAL FRAME: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
BEARING WALLS
EXTERIOR: NONCOMBUSTIBLE, 3 -HOUR FIRE RESISTIVE
INTERIOR: NONCOMBUSTIBLE, 3-HOUR FIRE RESISTIVE
NON-BEARING WALLS AND PARTITIONS
EXTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE RESISTIVE AT GREATER THAN 30' SEPARATIONS
INTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE-RESISTIVE
FLOOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE
ROOF: NONCOMBUSTIBLE, 1.5-HOUR FIRE RESISTIVE
SHAFT ENCLOSURES 2-HOUR FIRE RESISTIVE >4 STORIES (IBC 713.4, LSC 12.3.6)
SHAFT ENCLOSURES 1-HOUR FIRE RESISTIVE <4 STORIES (IBC 713.4, LSC 12.3.6)
4. STRUCTURAL DESIGN SHALL COMPLY WITH CHAPTER 16 OF THE IBC.
5. ALLOWABLE HEIGHT: UNLIMITED FT (IBC, TABLE 504.3)
6. ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN: UNLIMITED (IBC, TABLE 504.4)
7. ALLOWABLE AREA: FULLY SPRINKLED: ALLOWABLE AREA: UNLIMITED (IBC, TABLE 506.2)
8. MEANS OF EGRESS
• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 8 FEET.
• AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN 44 IN.
CLEAR AND UNOBSTRUCTED WIDTH.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 42 INCHES FROM SLEEPING ROOMS.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES
• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.
• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)
9. OCCUPANCY SEPARATION: I-2 OCCUPANCY REQUIRES A 2-HR SEPARATION BETWEEN COMMON ADJACENT OCCUPANCIES (S-2, U, B, S-1, M) (IBC CHAPTER 5, LSC CHAPTER 18). NO OTHER OCCUPANCIES ARE FOUND WITHIN THE PROJECT AREA AND NONE ARE PROVIDED BY THE PROJECT.
SECTIONS OF HEALTH CARE FACILITIES SHALL BE PERMITTED TO BE CLASSIFIED AS OTHER OCCUPANCIES, PROVIDED THAT THEY MEET BOTH OF THE FOLLOWING
CONDITIONS: (LSC 18.1.3.3)
(1) THEY ARE NOT INTENDED TO PROVIDE SERVICES SIMULTANEOUSLY FOR FOUR OR MORE INPATIENTS FOR PURPOSES OF HOUSING, TREATMENT, OR CUSTOMARY
ACCESS BY INPATIENTS INCAPABLE OF SELF-PRESERVATION.
(2) THEY ARE SEPARATED FROM AREAS OF HEALTH CARE OCCUPANCIES BY CONSTRUCTION HAVING A MINIMUM 2-HOUR FIRE RESISTANCE RATING IN ACCORDANCE
WITH CHAPTER 8.18.1.3.4 CONTIGUOUS NON-HEALTH CARE OCCUPANCIES.
10. MEANS OF EGRESS
• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 8 FEET.
• AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN 44 IN.
(1120 MM) IN CLEAR AND UNOBSTRUCTED WIDTH.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 42 INCHES FROM SLEEPING ROOMS; DIAGNOSTIC AND TREATMENT AREAS, SUCH AS X-RAY, SURGERY, OR PHYSICAL
THERAPY;.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES
• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.
• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)
• MAXIMUM TRAVEL DISTANCE, FULLY SPRINKLED: 200 FEET (LSC 18.2.6.2.1)
• COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET (LSC 18.2.5.3)
• DEAD END CORRIDORS SHALL NOT EXCEED 30 FEET. (LSC 18.2.5.2)
• MEANS OF EGRESS SHALL BE ILLUMINATED PER 7.9. (LSC 18.2.6.2.1)
• EMERGENCY LIGHTING SHALL BE PER 7.9. (LSC 18.2.9)
• EXIT SIGNAGE SHALL BE PROVIDED 7.10. (LSC 18.2.10)
11. WHERE GENERAL ANESTHESIA OR LIFE SUPPORT EQUIPMENT IS USED AND ESSENTIAL ELECTRICAL SYSTEM PER NFPA 99 SHALL BE PROVIDED.
12. HAZARDOUS AREAS. ANY HAZARDOUS AREAS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 8.7, AND THE AREAS DESCRIBED IN TABLE 18.3.2.1 SHALL BE
PROTECTED AS INDICATED. (LSC 18.3.2.2)
TABLE 18.3.2.1 (PARTIAL, AS APPLICABLE TO THE BUILDING'S 5TH FLOOR)
• ROOMS WITH SOILED LINEN IN VOLUME EXCEEDING 64 GAL (242 L)1 HOUR
• STORAGE ROOMS LARGER THAN 50 FT2(4.6 M2) BUT NOT EXCEEDING 100 FT2 (9.3 M2) AND STORING COMBUSTIBLE MATERIAL SEE 18.3.6.3.11.
• STORAGE ROOMS LARGER THAN 100 FT2 (9.3 M2) AND STORING COMBUSTIBLE MATERIAL 1 HOUR
• ROOMS WITH COLLECTED TRASH IN VOLUME EXCEEDING 64 GAL (242 L)1 HOUR† MINIMUM FIRE RESISTANCE RATING.
13. INTERIOR FINISH
• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 10.2 OF THE NFPA 101 TO CLASS A MATERIALS. (LSC 18.4.3.6.2)
• · CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.
• FLOORS: INTERIOR FLOOR FINISH SHALL BE CLASS I.
• FABRIC DRAPERIES, CURTAINS (EXCLUDING SHOWER CURTAINS, BUT INCLUDING CUBICLE CURTAINS), AND OTHER LOOSELY HANGING FABRICS AND FILMS
SERVING AS FURNISHINGS OR DECORATIONS IN HEALTH CARE OCCUPANCIES MUST MEET THE FLAME RESISTANCE REQUIREMENTS OF NFPA 701, STANDARD
METHODS OF FIRE TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS.
• UPHOLSTERED FURNITURE AND MATTRESSES. UPHOLSTERED FURNITURE AND MATTRESSES MUST ALSO MEET SPECIFIED REQUIREMENTS, BASED ON NFPA
260, NFPA 261, NFPA 266, 16 CFR 1632, ASTME E1537, AND ASTME E1590
14. EXTINGUISHMENTS REQUIREMENTS, PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 10. EXISTING FE/FEC SHALL REMAIN.
15. DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. EXISTING SYSTEMS SHALL REMAIN.
16. FIRE SUPPRESSION:
SPRINKLER SYSTEM: BUILDING IS REQUIRED TO BE SPRINKLED THROUGHOUT IN ACCORDANCE WITH NFPA 13. EXISTING SYSTEMS SHALL REMAIN
17. CONSTRUCTION BARRIERS CONSTRUCTED ALONG MEANS OF EGRESS SHALL BE CONSTRUCTED AND MAINTAINED PER NFPA 241.
CODE ANALYSIS - NFPA 101, INSTITUTIONAL HEALTHCARE CHAPTER 18
MEDICAL CENTER DIRECTOR,
ASSOCIATE DIRECTOR,
CHIEF OF STAFF,
AD OF PATIENT CARE SERVICES,
CHIEF OF ENGINEERING,
SAFETY OFFICER,
INFORMATION SECURITY OFFICER,
CHIEF OF POLICE,
INFECTION PREVENTION OFFICER,
CHIEF OF PSYCHIATRY,
NAGE
VA GRAND JUNCTION DESIGN ACCEPTANCE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs \s w h it c o m b .G
U
ID
O N
D E
S
IG
N \D o c u m e n ts
\1
.1
.0
V
A G ra n d
J u n c ti o n I D
IQ
Im p ro v e
P a ti e n t S a fe ty C e n tr a l
M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m
.r v t
/2
/2
:1
:5
P
M
GI000
COVER SHEET AND CODE REVIEW
GUIDON DESIGN
905 N. CAPITOL AVENUNE, SUITE 100
INDIANAPOLIS, IN 46204
317-800-6388
STEWART WHITCOMB
IMPROVE PATIENT SAFETY, 5P
GRAND JUNCTION, VAMC
575-18-106
BLDG. #1
08/24/2018 UJ STW
BID DOCUMENTS
FULLY SPRINKLERED
DEPARTMENT OF VETERAN AFFAIRS
GRAND JUNCTION, VAMC
BID DOCUMENTS
IMPROVE PATIENT SAFETY, 5P
575-18-106
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET AND CODE REVIEW
ARCHITECTURAL
AS001 ARCHITECTURAL GENERAL INFORMATION AND PHASING
AS100 ARCHITECTURAL PLANS AND DETAILS
AS200 REFLECTED CEILING PLAN AND DOOR DETAILS
Contact: Contact:
GRAND JUNCTION VETERANS HEALTH
CARE SYSTEM
GRAND JUNCTION CO.
ROJELIO CHAVEZ Jr.
CONTRACTING OFFICER'S REPRESENTATIVE
2121 NORTH AVENUE,
GRAND JUNCTION CO. 81501
p: 970-263-5016 e: Rojelio.Chavez@va.gov
OWNER
GUIDON DESIGN INC.
STEWART WHITCOMB, AIA, LEED AP BD+C
ARCHITECT, SUSTAINABILITY DIRECTOR
905 North Capitol Avenue Suite 100 Indianapolis, IN 46204 p: 317.800.6388 x 102 e: swhitcomb@guidondesign.com
ARCHITECT
AREA MAP
VICINITY MAP
VA MEDICAL CENTER
2121 NORTH AVENUE
BLDG. # 1 VA MEDICAL CENTER
PROJECT AREA, 5TH FLOOR
LIFE SAFETY OCCUPANCY COUNT
AREA SF OCC OCC FACTOR # OF OCC
TOTAL:
PROJECT
AREA (NET)
FLOOR TOTAL:
GROSS BUILDING AREA
5TH FLOOR (PROJECT AREA) SF
NO CHANGE, ETR
BUILDING TOTAL:
NO CHANGE, ETR
3800 8 STAFF 240 16
(8 UNITS) (8 VETS)
(PER UNIT)
NO CHANGE
T H
F L O O R
Revisions: Date:
UP
SECTION REFERENCE
DRAWING NUMBER
SHEET
LOCATION
DRAWING NUMBER
SHEET
LOCATION
DETAIL REFERENCE
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
N
NORTH ARROW
INCANDESCENT WALL MOUNTED LIGHTING
INCANDESCENT SURFACE MOUNT LIGHTING
SURFACE MOUNTED FLUORESCENT
RECESSED FLUORESCENT
HVAC RETURN AIR GRILLE
HVAC SUPPLY DIFFUSER
PENDANT LIGHT
ACCESS PANEL
EXIT LIGHTING
S
D
SPEAKER
SMOKE DETECTOR
INCANDESCENT RECESSED LIGHTING
A 9'-0"
CEILING TAG CEILING TYPE
FINISHED CEILING HEIGHT
REFER TO CEILING LEGEND FOR MORE
INFORMATION
EXTENT OF REVISION
REVISION SET
MECH/ELEC ITEMS: EXISTING TO REMAIN, NOT ALL ETR ITEMS ARE SHOWN
REFLECTED CEILING PLAN SYMBOLS
DETAIL/DRAWING SCALE
TITLE OF DETAIL/DRAWING
DETAIL/DRAWING NUMBER
SHEET NUMBER
GENERAL CONSTRUCTION NOTES
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION
MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL
DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH OWNER’S
REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY
SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY, ACCESS
CONTROL, ETC.
ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH
THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND
THE SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,
ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE
FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK
THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF
WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY
CERTAIN SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING
AND MAINTAINING SMOKE/FIRE RATINGS OF EXISTING CONSTRUCTION AS INDICATED
ON DRAWINGS. THIS INCLUDES PATCHING PENETRATIONS IN SHAFTS, WALLS, SLABS
AND ROOF. ONLY U.L. APPROVED METHODS, MATERIALS AND INSTALLATION ARE
ACCEPTABLE.
THE GENERAL CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL EXISTING
MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT WITH RESPECT TO THE
ARCHITECTURAL AND STRUCTURAL DETAILING OF SHAFTS, CHASES, CEILING
CONSTRUCTION, ETC.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR
MISSING DIMENSIONS.
DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING FINISH, FACE OF NEW
FINISH, FACE OF MASONRY, OR COLUMN GRID LINES UNLESS NOTED OTHERWISE.
PROJECT FLOOR ELEVATION (100’-0”) IS EQUAL TO THE FINISH FLOOR SLAB OF THE
EXISTING SLAB FLOOR CONSTRUCTION UNLESS OTHERWISE NOTED.
ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.
CONTRACTOR SHALL PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED
AS “TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE
DETAIL, AREA, OR ITEM REFERENCED.
PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, STORAGE,
PROTECTION, MOUNTING, INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.
INSTALL, INSTALLED, OR INSTALLATION WORK SHALL BE OWNER FURNISHED
MATERIALS AND EQUIPMENT INSTALLED BY THE CONTRACTOR. CONTRACTOR IS
RESPONSIBLE FOR COORDINATION OF MATERIAL DELIVERY, MOUNTING,
INSTALLATION AND ROUGH IN.
FURNISHED WORK SHALL BE CONTRACTOR SUPPLIED MATERIALS AND EQUIPMENT
TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY
AND ROUGH-IN.
ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED
OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
THE CONTRACTOR SHALL RESTRICT USE AND AVALIABILITY OF POWER ACTUATED
TOOLS, SUCH AS BUT NOT LIMITED TO; NAIL GUNS, GRINDERS, SAWS), TO ENSURE
SAFETY OF STAFF AND PATIENTS. SECURE TOOLS WHEN NOT IN USE AND DURING
TRANSPORT THROUGH PATIENT SPACE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY AND BUILDING SERVICE LINES. DAMAGE TO ELECTRICAL, PLUMBING, DUCTS,
PIPES, OR OTHER UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS SHALL BE
REPAIRED AT NO COST TO THE OWNER AND AS SOON AS POSSIBLE.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION,
FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE.
ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE
REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.
IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT
DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER
QUALITY OF WORK, AS DETERMINED BY THE COR, SHALL BE PROVIDED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
ARCHITECTURAL SYMBOLS
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
BUILDING X
XXXX
X
XXXX
ELEVATION REFERENCES
NEW WALL
WALL TO BE
REMOVED
EXISTING WALL TO
REMAIN
TEMPORARY IC
BARRIER WALL
CONSTRUCTION
ROOM
ROOM TAG
# PLAN NOTE
NEW DOOR
EXISTING DOOR
DEMOLISHED DOOR
REVISION TO PLAN CALLOUT
WALLS
DOOR TAG
DOORS
SWING SYMBOL IS DIAGRAMMATIC, MATCH EXISTING
SWING AND ORIENTATION.
ARCHITECTURAL ABBREVIATIONS
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
NOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPD APPROVED
APROX APPROXIMATE
ARCH ARCHITECT
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
AUTO AUTOMATIC
AUX AUXILIARY
AWI ARCHITECTURAL WOODWORKING INSTITUTE
BAT BATTEN
BKG BACKING
BLD/BLDG BUILDING
BLKG BLOCKING
BLKT BLANKET
BM BEAM OR BENCHMARK
BOT BOTTOM
BRCG BRACING
C CHANNEL OR CELSIUS
C TO C CENTER TO CENTER
CB CORNER BEAD
CC CUBIC CENTIMETER
CEM PLAS CEMENT PLASTER
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CHFR CHAMFER
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
COL COLUMN
COMM COMMUNICATION
CORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CRS COLD ROLLED STEEL
CSK COUNTER SUNK
CTG COATING
CTR CENTER
CTRL CONTROL
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGONAL OR DIAGRAM
DIFF DIFFERENCE
DIM DIMENSION
DIR DIRECTION
IST DISTANCE
DIV DIVISION
DOC DOCUMENT
DOZ DOZEN
DN DOWN
DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE
PAR PARALLEL OR PARAPET
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC POLYCARBONATE
PCF POUNDS PER CUBIC FOOT
PEN PENETRATE
PERP PERPENDICULAR
PL PLATE, PROPERTY LINE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PREFIN PREFINISH
PREV PREVIOUS
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTR QUARTER
QTY QUANTITY
R RADIUS
RA RETURN AIR
RBR RUBBER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECT RECTANGLE
REF REFERENCE
REQ REQUIRE/REQUIRED
RESIL RESILIENT
RET RETURN
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
RPM REVOLUTIONS PER MINUTE
RT RIGHT
SA SUPPLY AIR
SALV SALVAGE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCRN SCREEN
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR OR SOAP
DISPENSER
SECT SECTION
SEG SEGMENT
SEL SELECT
SF SQUARE FOOT (FEET)
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SIM SIMILAR
SK SKETCH
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
S SOUTH
SPEC SPECIFICATION
SPKLR SPRINKLER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STNLS STAINLESS
STOR STORAGE
STRUCT STRUCTURAL
SYNTH SYNTHETIC
SYS SYSTEM
E EAST
EA EACH
EFF EFFICIENCY
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL OR EQUALLY SPACED
EQUIP EQUIPMENT
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
ETR EXISTING TO REMAIN
ETS EXPOSE TO STRUCTURE
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FCTY FACTORY
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIL FILLET
FIN FINISH
FIXT FIXTURE
FLG FLOORING
FLR FLOOR
FO FINISHED OPENING
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FRMG FRAMING
FS FEDERAL SPECIFICATION
FT FEET OR FOOT
FURG FURRING
FURN FURNISH OR FURNITURE
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GL GLASS
GLU LAM GLUED LAMINATED WOOD
GRTG GRATING
GSM GALVANIZED SHEET METAL
GT GROUT
GUAR GUARANTEE
GYP GYPSUM
H HIGH
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HGR HANGER
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HW HOT WATER
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTL INTERNATIONAL
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAM LAMINATE
LAM GL LAMINATED GLASS
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE OR LEFT HAND REVERSE
LIN LINEAR
LIQ LIQUID
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MAX MAXIMUM
MCB METAL CORNER BEAD
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL OR MEDIUM
MEMO MEMORANDUM
MFD MANUFACTURED
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE OR MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
mm MILLIMETER
MO MASONRY OPENING OR MOTOR OPERATED
MOD MODEL, MODIFY OR MODULE
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NATL NATIONAL
NEG NEGATIVE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
OR OUTSIDE RADIUS
OUT OUTLET
OZ OUNCE
T TREAD
TA TOILET ACCESSORY
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TD TOWEL DISPENSER
TECH TECHNICAL
TEMP TEMPERATURE OR TEMPORARY
THD THREAD
THERM THERMAL
THK THICKNESS
TMPD TEMPERED
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UL UNDERWRITERS LABORATORIES
UNFIN UNFINISH
UNO UNLESS NOTE OTHERWISE
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAR VARIES
VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WD WOOD
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WIN WINDOW
M WIRE MESH
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
YD YARD
YR YEAR
TEMPORARY MEASURES AND PHASING LEGEND
TEMPORARY WALLS. SEE PLAN AND
PLAN NOTES
TEMPORARY CONSTRUCTION ACCESS
AND DUST CONTROL DOORS
PROJECT BOUNDARY
BEYOND PROJECT BOUNDARY
PROJECT PHASE A WORK
PROJECT PHASE B WORK
PROJECT PHASE C WORK
PROJECT PHASE D WORK
PROJECT WORK UNASSIGNED TO ANY
SPECIFIC PHASE4
INFECTION CONTROL PLAN NOTES
INFECTION CONTROL PROJECT INFORMATION
CONSTRUCTION ACTIVITY - FIRE RISK: Type C
PATIENT RISK GROUP: HIGH RISK
CLASS OF PRECAUTION MATRIX: III/IV
PROVIDE TEMPORARY MEASURE IN ADDITION TO EXISTING SECURITY DOOR
TO PROVIDE INFECTION CONTROL. REFER TO SPECIFICATION DIV 01.
PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR WITH
ACCESS CONTROL LOCK AND AIR FILTRATION W/ NEGATIVE RESSURE REFER
TO SPECIFICATIONS AND COORDINATE WITH COR.
PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION
WITH AIR FILTRATION AND NEGATIVE RESSURE. REFER TO SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
PROVIDE TEMPORARY INFECTION CONTROL PLASTIC BARRIER WALL
CONSTRUCTION WITH AIR FILTRATION AND NEGATIVE RESSURE. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED
BY CLASS IN SPECIFICATION 01 35 26 AND ADDITIONAL INFORMATION.
REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE
FOR ADDITIONAL INFORMATION.
PROJECT SHALL BE COMPLETED IN SIX (6) PHASES, INCLUDING MOBILIZATION
AND CLOSE/OUT.
COORDINATE FULL SCOPE OF WORK WITH EXISTING CONDITIONS AND FIELD
VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE
CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE
PROJECT BOUNDARY.
COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER
WALL CONSTRUCTION, NEGATIVE AIR PRESSURE AND FILTRATION, AND
INFECTION CONTROL (IC) MEASURES WITH COR AND PATIENT SAFETY/
INFECTION CONTROL REPRESENTATIVE. TEMPORARY IC BARRIER WALL
CONSTRUCTION LOCATIONS IN DRAWINGS ARE APPROXIMATE. CONTRACTOR
SHALL PROVIDE DRAWING TO COR AND PATIENT SAFETY/ INFECTION
CONTROL REPRESENTATIVE ONCE ICRA PROTOCOLS AND PLAN IS
APPROVED.
SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR
AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING
INFORMATION FOR ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED
CMP SCHEDULE FOR WORK ALSO REQUIRED ABOVE AND BELOW THE FLOOR
PLATE OF THE PROJECT BOUNDARY.
EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED
DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF
OPERATION.
WORK REQUIRING VIBRATION, LOAD NOISE, OR IMPACT NOISE SHALL TAKE
PLACE BETWEEN THE HOURS OF 10:00 AM AND 3:00 PM. EVERY EFFORT
SHALL BE MADE TO KEEP NOISE AND VIBRATION TO A MINIMUM.
COORDINATE WITH COR
PROVIDE A 24"X36" STICKY WALK OFF MAT AND HAND SANITIZER AT EACH
TEMPORARY DOOR LOCATION. MAT SHALL BE REPLACED OR CLEANED AS
NECESSARY
PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH
TEMPORARY DOOR LOCATION. MATERIALS AND METHODS SHALL BE
APPROVED BY VA STAFF
CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,
MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE
LIQUIDS UP TO 30 GALLONS.
ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH
4 MIL. POLY SHEET.
ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT
BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED
ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED
WITH A LID. DUMPSTER SHALL BE PROVIDED BY CONTRACTOR
ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY
STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE
MATERIALS SHALL NOT BE STORED IN THE FACILITY.
PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE
PROJECT BOUNDARY.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
INFECTION CONTROL GENERAL NOTES
PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT
CONSTRUCTION, EXCEPT PHASE A, B, C, AND D.
WORK IN THIS AREA CAN BE COMPLETED AT ANY PHASE, WITH INDICATED
INFECTION CONTROL AND SAFETY MEASURES, REFERENCE SPECIFICATIONS.,
COORDINATE WITH COR.
WORK SHALL NOT BE COMPLETED DURING NIGHT SHIFTS, 5:00 PM TO 5:00 AM,
WITHOUT AUTHORIZATION BY COR. ALL WORK TO BE COMPLETED AND OPEN
FOR VA MEDICAL CENTER USE AT THE END OF EACH PHASE.
REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURATION
FOR EACH PHASE AND AREA OF WORK.
PHASE 1 COMPLETION SHALL BE 'PUNCHED' BY A/E AND VA TO ESTABLISH
FINISH AND COMPLETION STANDARDS FOR THE PROJECT.
PHASING PLAN NOTES #
A.
B.
C.
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
STAIR
CONFERENCE
RM
CORRIDOR
SECURE
ENTRY
NURSE
STATION
ISOLATION
RM
VESTIBULE
5010B
TOILET RM
5010A
ISOLATION
RM
DAY RM
PATIENT RM
CORRIDOR
STAIR
ELEC RM
5008A
JAN RM
5008B
PATIENT
STORAGE
2 2
EXIT
EXIT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs \s w h it c o m b .G
U
ID
O N
D E
S
IG
N \D o c u m e n ts
\1
.1
.0
V
A G ra n d
J u n c ti o n I D
IQ
Im p ro v e
P a ti e n t S a fe ty C e n tr a l
M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m
.r v t
/2
/2
:1
:5
P
M
AS001
ARCHITECTURAL GENERAL
INFORMATION AND PHASINGGUIDON DESIGN
905 N. CAPITOL AVENUNE, SUITE 100
INDIANAPOLIS, IN 46204
317-800-6388
STEWART WHITCOMB
IMPROVE PATIENT SAFETY, 5P
GRAND JUNCTION, VAMC
575-18-106
BLDG. #1
08/24/2018 UJ STW
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AS001
1 5TH FLOOR PHASING PLAN
UP
UP
ARCHITECTURAL PLAN NOTES
PROVIDE PSYCHIATRIC INTERIOR RETROFIT WINDOW AT INTERIOR SIDE OF
EXISTING WINDOW FRAME, VERIFY EXISTING CONDITIONS AND COORDINATE
WITH STUD FRAMING FOR MOUNTING SURFACE. FRAME IS APPROXIMATELY 48"
W AND 60" TALL, SEE SCHEDULE AND TYPICAL ELEVATIONS ON AS200.
COORDINATE W/ NEW BULKHEAD CONSTRUCTION.
REFERENCE DEMO. PLANS FOR REMOVED ACCESS PANEL/HATCH IN WALL.
PROVIDE HEAVY DUTY ACCESS PANEL TO MATCH EXISTING SIZE AND
ORIENTATION. HARDWARE SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN
CYLINDER. REFERENCE ALTERNATE B: OMIT ACCESS PANEL/HATCH
REPLACEMENT WORK.
PROVIDE DOOR LEAF/SLAB TO MATCH EXISTING, APPROX. 3" LESS THAN
FRAME TO ACCOMMODATE CONTINUOUS HINGE SPECIFIED WITH EXISTING
ANTI-BARRICADE FRAME. INSTALL SALVAGED HARDWARE, EXCEPT PROVIDE
CONTINUOUS HINGE.
REFERENCE DEMO PLANS FOR REMOVED HINGES. PROVIDE DOOR LEAF/SLAB
APPROX. 3" LESS THAN FRAME TO ACCOMMODATE CONTINUOUS HINGE AS
SPECIFIED WITH EXISTING ANTI-BARRICADE FRAME. INSTALL SALVAGED
HARDWARE AND ADJUSTED FOR HINGE AND POSITION. REFERENCE
ALTERNATE A: OMIT DOOR AND DOOR HARDWARE REPLACEMENT WORK.
PROVIDE PROTECTION FOR WALL MURAL WITH SHEET OR BOARD PRODUCT
MOUNTED INPLACE THROUGHOUT PHASE. REMOVE ANY HANGERS OR
FASTENERS FROM THE AREA PATCH/REPAIR AND PAINT SURROUNDING
FINISHES TO LIKE-NEW CONDITION
WORK PER ALTERNATE C: OMIT DOOR AND WINDOW WORK FROM SELECTED
SPACES.
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
STAIR
CONFERENCE
RM
CORRIDOR
SECURE
ENTRY
NURSE
STATION
ISOLATION
RM
VESTIBULE
5010B
TOILET RM
5010A
ISOLATION
RM
DAY RM
PATIENT RM
CORRIDOR
STAIR
ELEC RM
5008A
JAN RM
5008B
PATIENT
STORAGE
1.
2.
1. 1. 1.
1. 1. 1.
3.4.4.4.
4.
4.4.4.4.
1.
2.
1.
2.
1.
2.
1.
2.
1.
2.
2. 2. 2.
33B33A13141516
17 18 19 20
21 22 23B 23A
5.
5.
5.5.5.
5.
5.5.5.
2.
2.
5.
5.
6.
6.
2.
DEMOLITION GENERAL NOTES
COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND
REPAIR NECESSARY TO COMPLETE THE WORK AND REMODEL
CONSTRUCTION SHALL BE PROVIDED. CONTRACTOR SHALL REMOVE
EXISTING IMPROVEMENTS WHETHER OR NOT SPECIFICALLY INDICATED ON
THE DRAWINGS TO FACILITATE THE COMPLETION OF ALL REQUIRED WORK.
CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL QUANTITIES AND ITEMS
REQUIRED TO BE REMOVED.
REFER TO ARCHITECTURAL SYMBOLS ON SHEET AS001 FOR DEMOLITION
SYSTEMS AND DRAWING NOMENCLATURE.
EXISTING STRUCTURE WITHIN THE PROJECT BOUNDARY SHALL REMAIN
UNLESS OTHERWISE NOTED.
SURFACES TO BE CUT AND CONDITIONS UNDER WHICH CUTTING IS TO BE
PREFORMED SHALL BE REVIEWED BY CONTRACTOR PRIOR TO CUTTING TO
VERIFY NO UNSAFE OF UNSATISFACTORY CONDITIONS EXIST. COORDINATE
WITH OCCUPANTS, PATIENT CARE, AND NOTIFY COR/VA OF ALL POWERED
EQUIPMENT TO BE USED TO FACILITATE NOISE/DISTURBANCE DISCUSSIONS.
SUCH CONDITIONS SHALL BE RECTIFIED BEFORE WORK MAY PROCEED.
EXTENTS OF DEMOLITION SHALL BE COORDINATE WITH THE ARCHITECTURAL
FLOOR PLAN AND DETAIL DRAWINGS.
DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE
APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL SCOPE OF WORK TO
BE REMOVED OR TEMPORARILY REMOVED TO ACCOMMODATE NEW
CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF
NEW CONSTRUCTION TO PROVIDE ADEQUATE AREA FOR THIS WORK.
MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER TO RECEIVE
NEW FINISHES. DEMOLITION SHOULD BE PERFORMED IN A MANNER SUCH
THAT THE CONTRACTOR CAN SEAMLESSLY PATCH NEW WORK TO BE
SMOOTH AND UNDETECTABLE.
ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, DAMAGED AND
BROKEN GYPSUM BOARD CEILINGS SHALL BE PATCHED AND PAINTED TO
SEAMLESSLY MATCH EXISTING CEILING COLOR FOLLOWING ABOVE CEILING
DEMOLITION ACTIVITY. THIS SHALL INCLUDE REPAIR TO THE CEILING GRID,
SUSPENSION SYSTEM, GYPSUM BOARD, FINISH AND ALL ASSOCIATED
ASSEMBLIES AS WELL AS THE REPLACEMENT OF DAMAGED CEILING PANELS,
WITHIN AND BEYOND PROJECT LIMITS.
COORDINATE FULL SCOPE OF DEMOLITION WORK WITH ENGINEERING AND
VENDOR DRAWINGS.
EXISTING FLOOR FINISH AND WALL MURALS ARE TO REMAIN. EMPLOY ALL
NECESSARY MEANS AND METHODS TO PROTECT THE FLOOR FINISH, WALL
MURALS IN ROOMS AND CORRIDOR FROM DAMAGE, SCRATCHES, CRACKING
OR OTHER DEGRADATION. CONTRACTOR SHALL REPLACE FLOORING FINISH
OR ANY MURAL DAMAGED THROUGH THE COURSE OF THE WORK.
A
B
C
D
E
F
G
H
I
J
DEMOLITION PLAN NOTES
REMOVE HEAD, JAB AND SILL TRIM AND FINISH FROM WINDOW AND WALL.
REMOVE 3 5/8" STUD FRAMING AT SILL, JAMB AND HEAD OF WINDOW.
PREPARE FOR REPLACEMENT FRAMING AS INDICATED IN ARCHITECTURAL
DETAILS AND SPECIFICATIONS. PREPARE ADJACENT AREA TO RECEIVE FINISH
TO MATCH EXISTING.
REFERENCE REFLECTED CEILING PLAN FOR ACCESS HATCH TO BE REMOVED
IN THIS AREA.
REMOVE STAINLESS STEEL ACCESS PANEL FROM CORRIDOR WALL, PREPARE
FOR REPLACEMENT HEAVY DUTY STAINLESS STEEL HATCH. REFERENCE
ALTERNATE B: OMIT ACCESS PANEL/HATCH REPLACEMENT WORK.
REMOVE AND SALVAGE DOORS LEAVES AND HARDWARE. DOOR FRAME TO
REMAIN IN PLACE. SALVAGE LEAVES TO OWNER AND REMOVE PIVOT-SET
RECEIVER OR BRACKET FROM DOOR. REMOVE PIVOT-SET PIN/SHAFT, CUT OR
GRIND. PROTECT OR REPLACE EXISTING FLOORING. PIVOT SET ANCHOR AND
CONCEALED COMPONENTS ARE TO REMAIN WITHIN FLOOR. DO NOT
DEMOLISH FLOOR DECK OR FINISH. REFERENCE ALTERNATE A: OMIT DOOR
AND DOOR HARDWARE REPLACEMENT WORK.
REMOVE AND SALVAGE DOORS AND HARDWARE, STORE DOOR AS DIRECTED
BY VA COR. DOOR FRAME TO REMAIN IN PLACE. REMOVE PIVOT-SET
PIN/SHAFT, CUT OR GRIND. PROTECT OR REPLACE EXISTING FLOORING.
PIVOT SET ANCHOR AND CONCEALED COMPONENTS ARE TO REMAIN WITHIN
FLOOR. DO NOT DEMOLISH FLOOR DECK OR FINISH.
WORK PER ALTERNATE C: OMIT DOOR MODIFICATIONS AND WINDOW FROM
SELECTED SPACES.
REMOVE AND SALVAGE DOORS HARDWARE. REMOVE PIVOT-SET RECEIVER
OR BRACKET FROM DOOR. PROTECT PIVOT-SET PIN/SHAFT AND EXISTING
FLOORING.
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
STAIR
CONFERENCE
RM
CORRIDOR
SECURE
ENTRY
NURSE
STATION
ISOLATION
RM
VESTIBULE
5010B
TOILET RM
5010A
ISOLATION
RM
DAY RM
PATIENT RM
CORRIDOR
STAIR
ELEC RM
5008A
JAN RM
5008B
PATIENT
STORAGE
1.
2.
1. 1. 1.
1.
1.
1.
3.4.
4.
4.
1.
2.
1.
2.
1.
2.
1.
2.
1.
2.
2. 2.
2.
2.
4.
4. 4.3.
6.
6.
3.
7.
5020E
EXISTING WINDOW, TO
REMAIN
REPAIR GYP BOARD
BULKHEAD W/ IMPACT
RESISTANT GYP.
PSYCHIATRIC RETROFIT
INTERIOR WINDOW SILL AS
SPECIFIED.
REPAIR GYP BOARD WALL W/
IMPACT RESISTANT GYP.
EXISTING WINDOW, TO
REMAIN
PSYCHIATRIC RETROFIT
INTERIOR WINDOW JAMB AS
SPECIFIED.
PSYCHIATRIC RETROFIT
INTERIOR WINDOW HEAD AS
SPECIFIED.
PROVIDE 12 GA. 3 5/8" DOUBLE
KING STUD CORNERS W/
BLOCKING.
TYPICAL
A S
S C
H E
D U
LE
D
AS SCHEDULED
PROVIDE SWING FOR EASE
OF MAINTENANCE ACCESS,
CORD. W/ ADJACENT WALLS
AND JAMB CONDITION.
WINDOW SHALL RESIST 2000
FT-LBS OF HUMAN IMPACT
ENERGY
1/4" MAXIMUM EDGE
PROFILE.
SEAL TO GYP BOARD WITH
TAMPER RESISTANT
SEALANT.
EXISTING WINDOW,
TO REMAIN
REMOVE GYP BOARD AND STUD
FROM WALL; ACCOMMODATE
NEW CONSTRUCTION
REMOVE GYP BOARD AND STUD
FROM WALL; ACCOMMODATE
NEW CONSTRUCTION
REMOVE GYP BOARD AND STUD
FROM BULKHEAD;
ACCOMMODATE NEW
CONSTRUCTION
M A
T C
H E
X
IS
T
IN
G S
IL
L
E X
IS
T
IN
G
W
IN
D O
W O
P E
N
IN
G
ROUGH WIDTH, SEE SCHEDULE
PROVIDE 12 GA. 3 5/8" DOUBLE KING STUD
CORNERS W/ BLOCKING
PROVIDE 12 GA. 3 5/8" STUD HEADER W/
BLOCKING AND CHANNEL
PROVIDE 5/8" IMPACT RESISTANT GYP BOARD, TYP.
PROVIDE 12 GA. DOUBLE STUD SILL W/ CHANNEL AND
BLOCKING TO EXTERIOR CMU WALL @ 12" O.C.
PROVIDE 12 GA. 3 5/8" STUDS @ MAX 16" O.C.
W/ TRACK TO STRUCTURAL DECK BELOW
PROVIDE 12 GA. 3 5/8" STUDS @ MAX 16" O.C.
RESTORE WALL BOARD AND CEILING WITH
BLOCKING AND IMPACT RESISTANT GYP BOARD, TYP.
4 7/8" BULKHEAD W/ 3 5/8" STUDS AND 5/8 IMPACT RESISTANT
GYP ON EACH SIDE, COORDINATE W/ PSYCHIATRIC WINDOW
SWING AND CEILING HEIGHT.
S E
C U
R
IT
Y W
IN
D
O W
R O
U G
H H
E
IG
H T
ANCHOR STUDS TO STRUCTURAL DECK
ABOVE
PROVIDE 12 GA. 3 5/8" STUD BLOCKING @ MAX 16" O.C.
TO EXTERIOR CMU WALL, TYP.
ALTERNATE BID ITEMS
ALTERNATE NO. A : OMIT DOOR AND DOOR HARDWARE REPLACEMENT WORK.
DO NOT PROVIDE LABOR, MATERIALS, COORDINATION OR OVERSIGHT FOR
DOOR REMOVAL, SALVAGE, AND DOOR MODIFICATION TO UPGRADE HINGES
TO CONTINUOUS HINGE AT PATIENT ROOMS
ALTERNATE NO. B: OMIT ACCESS PANEL/HATCH REPLACEMENT WORK. DO NOT
PROVIDE LABOR, MATERIALS, COORDINATION OR OVERSIGHT FOR STAINLESS
STEEL SECURITY HATCH REPLACEMENT, AND ASSOCIATED SELECTIVE
DEMOLITION AND INFECTION CONTROL IN CORRIDOR 5032, WALLS AND
CEILING HATCHES.
ALTERNATE NO. C: OMIT DOOR MODIFICATIONS AND WINDOW FROM SELECTED
SPACES. DO NOT PROVIDE LABOR, MATERIALS, COORDINATION OR
OVERSIGHT FOR SELECTIVE DEMOLITION, INTERIOR WINDOWS FOR ROOMS
5021, 5022, 5023, CONTINUOUS HINGES FOR 5010A, 5011 AND 5012, AND ANY
ASSOCIATED INFECTION CONTROL.
NOTE: ALL PATIENT ROOM CEILING HATCHES ARE BASE BID WORK
REPLACEMENT OF DOOR 5020 AND HARDWARE INSTALLATION IS
BASE BID WORK.
SEE SPECIFICATIONS 010000 FOR ADDITIONAL INFORMATION ON BID
ITEMS AND ALTERNATES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs \s w h it c o m b .G
U
ID
O N
D E
S
IG
N \D o c u m e n ts
\1
.1
.0
V
A G ra n d
J u n c ti o n I D
IQ
Im p ro v e
P a ti e n t S a fe ty C e n tr a l
M o d e l_ s w h it c o m b g u id o n d e s ig n .c o m
.r v t
/2
/2
:1
:5
P
M
AS100
ARCHITECTURAL PLANS AND
DETAILSGUIDON DESIGN
905 N. CAPITOL AVENUNE, SUITE 100
INDIANAPOLIS, IN 46204
317-800-6388
STEWART WHITCOMB
IMPROVE PATIENT SAFETY, 5P
GRAND JUNCTION, VAMC
575-18-106
BLDG. #1
08/24/2018 UJ STW
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AS100
3 5TH FLOOR BEHAVIORAL HEALTH UNIT
SCALE: 1/8" = 1'-0"AS100
1 5TH FLOOR DEMOLITION PLAN BEHAVIORAL HEALTH UNIT
SCALE: 1" = 1'-0"AS100
4 TYPICAL HEAD, JAMB AND SILL
SCALE: 1/4" = 1'-0"AS100
6 WINDOW ELEVATION
SCALE: 1/2" = 1'-0"AS100
2 TYPICAL SECTION, DEMOLITION AT WINDOW
SCALE: 1/2" = 1'-0"AS100
5 WINDOW FRAMING ELEVATION
WINDOW SCHEDULE
MARK TYPE OPERATION
DESIGN
HEIGHT*
DESIGN
WIDTH* SILL HEIGHT BASSIS OF DESIGN Comments
13 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW LEFT JAMB. MODIFY WALL.
14 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW LEFT JAMB. MODIFY WALL.
15 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
16 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
17 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
18 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/4" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SHALLOW RIGHT JAMB, MODIFY WALL
19 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
20 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 5" 3' - 11" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
21 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/2" 4' - 2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC REMOVE AND REINSTALL CURTAINS, SEE ALT C
22 PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C
23A PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 4 5/8" 4' - 0 1/4" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C
23B PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 4 1/2" 4' - 1" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC SEE ALT C
33A PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
33B PSYCHIATRIC INTERIOR RETROFIT MAINT. ONLY 5' - 7 1/4" 4' - 2 1/2" MATCH EXISTING, VERIFY 3'-10 1/2" WAUSAU 2187-DT S.E.A.L.™ PSYCHIATRIC
NOTES: DESIGN HEIGHT AND WIDTH HAVE BEEN MADE WITH ASSUMPTIONS ABOUT HIDDEN CONDITIONS WITHIN WALL. CONTRACTOR TO FIELD VERIFY AND COORDINATE HEIGHT AND WIDTH.
ALL GLAZING SHALL BE 1/2" COATED POLYCARBONATE, AS SPECIFIED
PROVIDE EACH WINDOW WITH KEY LOCKING KNOB FOR OPERATION, LIGATURE FREE KNOB FOR BLIND CONTROL, EXISTING FINISH SCHEDULE
FINISH MARK FINISH MANUFACTURER PATTERN/STYLE COLOR SIZES COMMENTS
HCF-1 HIGH PERFORMANCE COATED FLOOR -- SLIP-RESISTANT TEXTURE BEIGE / TAUPE 3 COAT FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.
ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG FINE FISSURED WHITE 2X4 PRODUCT NO. 1763
ACT-X ACOUSTICAL CEILING TILE MATCH EXISTING -- WHITE 2X4 --
PL-1 PLASTIC LAMINATE WILSONART 4845-60 SATIN TWILIGHT ZEPHYR N/A COUNTER TOP SPLASH AND TRIM. NOT USED IN PROJECT
SCOPE
PL-2 PLASTIC LAMINATE WILSONART 10776-60 SATIN KENSINGTON MAPLE N/A CABINET FACES AND BASE
CPT-1 CARPET TILE MANNINGTON 8206 - EXPEDITION MATCH EXISTING 2x2 NOT USED IN PROJECT SCOPE
CPT-2 CARPET TILE -- MATCH EXISTING MATCH EXISTING 2x2 NOT USED IN PROJECT SCOPE
RS-1 RESILIENT SHEET VINYL WOOD GRAIN, SIM. 4" WOOD LIGHT BROWN WOOD ROLL FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.
TS-1 TRANSITION STRIP METAL SCHLUTER SCHLUTER RENO-TK STAINLESS STEEL CERAMIC TO CARPET, MAY NOT OCCUR IN PROJECT
TS-2 TRANSITION STRIP METAL SCHLUTER SCHLUTER RENO-U STAINLESS STEEL CERAMIC TO RESILIENT FLOOR, MAY NOT OCCUR IN PROJECT
TS-3 TRANSITION STRIP RESILIENT JOHNSONITE MATCH 80 MATCH ADJACENT BASE RESILENT SHEET VINYL TO HPC OR CARPET
RB-1 RESILIENT BASE JOHNSONITE 80 FAWN 6" COVE BASE, COIL LENGTH, MAY NOT OCCUR IN PROJECT
RB-2 RESILENT BASE ROPPE P130 BUCKSKIN 6" EXISTING COVE BASE, MAY NOT OCCUR IN PROJECT
PT-1 PAINT #1 EXISTING, SHERWIN WILLIAMS SW 6112 BISCUIT - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD
PT-2 PAINT #2 EXISTING, SHERWIN WILLIAMS SW 6385 DOVER WHITE - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD
PT-3 PAINT #3 EXISTING, SHERWIN WILLIAMS SW 6113 INTERACTIVE CREAM - SEMI-GLOSS N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD
PT-4 PAINT #4 EXISTING, SHERWIN WILLIAMS - MATCH EXISTING N/A FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.
PT-5 PAINT #5 EXISTING, SHERWIN WILLIAMS SW 6165 CONNECTED GRAY - EGGSHELL N/A CONTRACTOR TO FIELD VERIFY MATCH, SW# 10 YEARS OLD
PT-X PAINT #0 EXISTING, SHERWIN WILLIAMS - MATCH EXISTING N/A FIELD MATCH EXISTING, CONFIRM WITH PROVIDER ON SITE.
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE WALLS CLG FIN. COMMENTS
5008A ELEC RM ETR ETR ETR ETR NO WORK IN THIS SPACE
5008B JAN RM ETR ETR ETR ETR NO WORK IN THIS SPACE
5010A TOILET RM ETR ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK
5010B VESTIBULE ETR, 1. RS-1 ETR, RS-1 ETR ETR REFERENCE DOOR SCHEDULE FOR WORK
5011 ISOLATION RM ETR, 1. RS-1 ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK
5012 ISOLATION RM ETR, 1. RS-1 ETR ETR ETR REFERENCE DOOR SCHEDULE FOR WORK
5013 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5014 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5015 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5016 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5017 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5018 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5019 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5020 PATIENT RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5021 CONFERENCE RM ETR ETR PT-X, 2. PROTECT EXISTING FINISHES AND FURNITURE
5022 CORRIDOR ETR ETR PT-X, 2. PROTECT EXISTING FINISHES
5023 SECURE ENTRY ETR ETR PT-X, 2. PROTECT EXISTING FINISHES
5028 STAIR ETR ETR ETR ETR NO WORK IN THIS SPACE
5029 STAIR ETR ETR ETR ETR NO WORK IN THIS SPACE
5030 PATIENT STORAGE ETR ETR ETR ETR NO WORK, NO ACCESS TO THIS SPACE
5031 NURSE STATION ETR ETR ETR ETR NO WORK IN THIS SPACE
5032 CORRIDOR ETR, 1. RS-1 ETR, RS-1 PT-X, 2. PT-2. 2. PROTECT EXISTING WALL MURAL AND FINISHES
5033 DAY RM ETR, 1. RS-1 ETR PT-X, 2. PT-2. 2. PROTECT EXISTING FINISHES AND FURNITURE
NOTES 1: PROTECT FLOOR THROUGHOUT WORK. REPLACE ANY AREAS DAMAGED BY CONTRACTOR AT NO COST TO VA.
2: PROVIDE PAINT AND SEALANT AT HATCHES REPLACED IN THE WORK.
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
STAIR
PATIENT RM
PATIENT RM
5015 PATIENT RM
PATIENT RM
5013 DAY RM
ISOLATION
RM
VESTIBULE
5010B
TOILET RM
5010A
ISOLATION
RM
NURSE
STATION
SECURE
ENTRY
CORRIDOR
CORRIDOR
CONFERENCE
RM
STAIR
1 1
REFLECTED CEILING PLAN GENERAL NOTES
REFLECTED CEILING PLAN NOTES
1.
2.
REMOVE 24" X 24" ACCESS PANEL/HATCH IN CEILING. PROVIDE HEAVY DUTY
ACCESS PANEL TO MATCH EXISTING SIZE AND ORIENTATION. HARDWARE
SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN CYLINDER.
REMOVE 18" X 18" ACCESS PANEL/HATCH IN CEILING. PROVIDE HEAVY DUTY
ACCESS PANEL TO MATCH EXISTING SIZE AND ORIENTATION. HARDWARE
SHALL INCLUDE MORTISE TYPE LATCH AND 5-PIN CYLINDER.
A
B
C
D
E
F
THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL BE COORDINATED WITH
THE EXISTING LAYOUT OF ALL CEILING ELEMENTS, HEIGHTS AND/OR
PENETRATIONS. COORDINATION OF THE HATCH INSTALLATION WITH ACCESS
CLEARANCE, MAINTENANCE WORK, AND FUNCTION OF EXISTING ABOVE
CEILING AND IN WALL EQUIPMENT, PANELS, AND OTHER ELEMENTS IN THE
FIELD.
THE CONTRACTOR IS TO VERIFY FIELD CONDITIONS, HATCH SWING/HINGE
DIRECTION, AND REPORT ANY DISCREPANCIES TO ARCHITECT AND COR.
CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)
SHALL BE PROTECTED THROUGHOUT CONSTRUCTION
DRYWALL CEILINGS SHALL BE PATCHED, PREPPED AND NEW FINISH APPLIED
TO MATCH EXISTING. ALL CEILINGS IN PROJECT AREA ARE DRYWALL/HARD LID.
REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON
GYPSUM BOARD PAINT FINISH.
ALL EXPOSED FASTENERS SHALL BE TAMPER RESISTANT THAT CANNOT BE
TURNED BY MAKESHIFT TOOLS.
2"
FRAMING STUD HEADER
RESCUE DOOR HOLLOW METAL DOOR
FRAME
SEALANT - BOTH SIDES
WALL TYPE, SEE PLANS
RESCUE STOP/ STRIKE
CORRIDOR
SIDE
TOILET
SIDE
FOR REFERENCE ONLY
2"
DOUBLE STUD FRAMING
RESCUE DOOR HOLLOW METAL
DOOR FRAME
SEALANT - BOTH SIDES
WALL TYPE, SEE PLANS
RESCUE STOP/ STRIKE
TOILET SIDE
CORRIDOR SIDE
FOR REFERENCE ONLY
D-1
A S
S C
H E
D U
LE
D
VERIFY WITH HINGE
3" LESS THAN EXISTING FRAME
F-1
ETR 2" TYP
RESCUE FRAME
E T
R
DOOR SCHEDULE COMMENTS
A
B
C
EXISTING ANTI-BARRIER HARDWARE AND FRAME TO REMAIN. PROTECT
FINISH. COORDINATE WITH NEW WORK.
TEMPORARY INFECTION CONTROL DOOR. SEE SHEET AS001 AND
SPECIFICATIONS FOR MORE INFORMATION. DOOR AND HARDWARE ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
REFER TO DETAILS INDICATED FOR JAMB, AND SPECIFICATIONS FOR DOOR
HARDWARE. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION.
DOOR AND FRAME GENERAL NOTES
CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL HARDWARE
REQUIREMENTS BETWEEN HARDWARE SUPPLIES,…