36C25919Q0507-003.pdf

PDF Posted

Attached to
(S)(660) Engineering Furniture Removal, Storage and Protection
Solicitation number
36C25919Q0507
Issued by

About this file

36C25919Q0507 P01 B2 Casework Attachment B RR ACM Survey VAMC Bldg 2 SLC UT 4-20-18.pdf

View the file

Other files

File Type Posted
36C25919Q0507-0001000.docx DOCX document
36C25919Q0507-0001000.docx DOCX document
36C25919Q0507-005.pdf PDF
36C25919Q0507-000.docx DOCX document
36C25919Q0507-004.pdf PDF
36C25919Q0507-002.pdf PDF
36C25919Q0507-001.xlsx XLSX spreadsheet
36C25919Q0507-001.xlsx XLSX spreadsheet
36C25919Q0507-002.pdf PDF
36C25919Q0507-004.pdf PDF
36C25919Q0507-003.pdf PDF
36C25919Q0507-000.docx DOCX document
36C25919Q0507-005.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS SURVEY AND ASSESSMENT

OF THE

VETERANS ADMINISTRATION MEDICAL CENTER

660-15-121 ENERGY EFFICIENCY BUILDING IMPROVEMENTS

BUILDING 2, A, B, AND C ZONES, GROUND FLOOR, 1ST FLOOR, 2ND FLOOR

LOCATED AT

550 FOOTHILL DRIVE

SALT LAKE CITY, UTAH

Prepared for:

Taqi H. Muhammad

Senior Project Manager 18300 East 71st Street, Suite 130

Denver, Colorado 80249 Office: (504) 378-7399 Mobile: (985) 789-3430

Prepared by:

Steven B. Smith AHERA Inspector #R17-1465-AI-O-UT

State of Utah, Inspector Certification Number: ASB-3274 State of Utah Company Certification: ASBC-237

Table of Contents

ASBESTOS

1.0 INTRODUCTION

2.0 EXECUTIVE SUMMARY

3.0 SAMPLING METHODS

4.0 SURVEY RESULTS

5.0 CONCLUSIONS

6.0 LIMITATIONS AND EXCLUSION OF WARRANTY

List of Appendices

Appendix A Sample Log

Appendix B Laboratory Report

Appendix C Photo Log

Appendix D Floorplans

Appendix E Certifications

Asbestos Survey Report Page 1 Veterans Administration Medical Center 660-15-121, Building 2, A, B, and C Zones

1.0 INTRODUCTION

R & R Environmental, Inc. (R & R) was contacted to conduct an asbestos survey for the Veterans Administration Medical Center, 660-15-121, Building 2, Zones A, B, C. The survey consisted of a visual assessment of the building’s interior floors and walls for suspect asbestos containing materials (ACM) and bulk sampling of the materials. The fieldwork component of this survey was conducted by Mr. Steve Smith, who is a Utah Accredited Asbestos Building Inspector, during the week of March 5, 2018.

This report presents the conditions and observations noted on the visit dates.

The following general information is included in this survey report:

• Executive Summary (Section 2.0)

• Sampling Methods (Section 3.0)

• Analytical Results (Section 4.0)

• Conclusions (5.0)

Asbestos Survey Report Page 2

2.0 EXECUTIVE SUMMARY

Asbestos-containing material (ACM) identified at the Veterans Administration Medical Center, 660-15-121 Building 2, Zones A, B, and C is as follows:

Material Location Quantity Asbestos Content Photo # Condition 12” Vinyl Tile and Mastic GA25C, GA23, GA21, GA21A, GA19, GA19A, GA19B, GA15, GA07, GA04, GA04A, GA04B, GA00, GA00B, GA00A, GA00C, GA02, GA10, GA12, GA20, GA18, GA06, GB00, GB01, GB09C, 1A00, 1B00, 1C00, 1A00A, 1A00B, 1B11, 1B07, 1A10, 1A17, 1A19, 1A25, 1A27, 1A23, 1A21, 1A30, 1A16, 1A18, 1A26, 1A34, 1A39, 1A36,1A38, 1A44, 1A46, 1A45, 1A47, 1A49, 1A53, 1A53A, 1A53B, 1A53C, 1A53D, 1A00, 2A20, 2A16, 2A10, 2A14, 2A12, 2A13, 2A21, 2A23, 2A15, 2A00AA, 2A17, 2A19, 2A19B, 2A19A, 2A11, 2A22, 2AA, 2A27A, 2A30, 2A32, 2A34, 2A31, 2A33, 2A38, 2A36, 2A00, 2B00, 2A09, 2B05, 2B08, 2C06, 2C04, 23,979 ft2 4% Chrysotile (Tile) 7% Chrysotile (Mastic)

2-3 Undamaged

Black Flooring Mastic GA25B, GA25I, GA36, GAA, GA17, GA13, GA05, GBA, 1C08, 1C06, 1C04, 1C02, 1C01, 1B11A, 1B00AA, 1B05, 1B01, 1B03, 1B05A, 1A01, 1A03, 1A03A, 1A04, 1A05, 1A07, 1A09, 1A33, 1A15, 1A13, 1A14, 1A24, 1A20, 1A22, 1A22A, 2BA, 1A48, 1A51, 1A50, 2A15, 2A27, 2A04A, 2C02, 2C01, 2B04A, 1A45B, 2A04, 2A07A

8,922 ft2 Up to 8% Chrysotile 4-5 Undamaged

9” Vinyl Floor Tile and Mastic

GA25, GA25A, GA25D,

GA25E, GA25F, GA25G,

GA25H, GA36, GA09, GA14,

GA16, 1A02, 1A32, 2A02,

2A07, 2A05, 2A03, 2A01, 2A02A, 2B06, 2B09, 2C03, 2C08, 3,921 ft2 Assumed 6-7 Undamaged

Duct Sealant Ducting Throughout 2,380 lf Assumed 6 Good

Asbestos Survey Report Page 3

Material Location Quantity % Asbestos Photo # Condition Thermal Systems Insulation – Pipe Support Insulation, Pipe Fittings

Piping Throughout 1,372 each

Assumed 9 Undamaged

Thermal Systems Insulation – Pipe Lagging Insulation

Piping Throughout 2,750 lf

Assumed

20 Undamaged

Exterior Wall Black Tar Interior Surface of Exterior Walls

32,500 ft Assumed

12 Undamaged

Laboratory Counter Top Rooms GA18, GA20 112 ft2 Assumed 13 Undamaged Black Sink Undercoating Rooms GA02, GA04, GA04A, GA10, GA14, GA16

7 each Assumed 14 Undamaged

Light Fixtured Wire Insulation

Rooms 1A28A 2 each Assumed - Undamaged

Insulation Tab Adhesive Room GA26 150 ft2 28% Chrysotile 15 Undamaged Cloth HVAC Vibration Isolator

Room GC03 12 lf 85% Chrysotile 16 Undamaged

Black Roofing Tar Penthouse Mechanical 265 ft2 Up to 11% Chrysotile 17 Undamaged Caulking Roof 120 lf 12% Chrysotile 18 Undamaged Roofing Material Roof >5,000 ft2 Assumed - Undamaged Wall System1 Scattered Throughout

>5,000 ft2

Overall <1% Chrysotile

(By Point Count) 20 Undamaged

Floor Leveling Compound2 GA15A, GA07A 214 ft2 <.25% Chrysotile (By Point Count)

19 Undamaged

NOTES:

1. Wall System material contains Chrysotile Asbestos in the joint compound with an overall asbestos content of less than 1%. According to the Federal Register page 542, Wednesday, January 5, 1994, 40 CFR Part 61, "Asbestos NESHAP Clarification Regarding Analysis of Multi-Layered Systems", when joint compound is applied to wallboard, it becomes an integral part of it, forming a wall system. Composite analysis of the wall system is to be conducted. In this case, the wall system contains less than 1% asbestos and is therefore not subject to the NESHAP. Removal of this material is a Class II Operation under OSHA, which requires 40-hour trained supervisors, trained workers and specific work practices (wet methods, prompt clean-up of debris, HEPA vacuums, etc.)

2. The Floor Leveling compound contains less than 1% asbestos and is therefore not subject to the NESHAP.

Removal of this material is a Class II Operation under OSHA, which requires 40-hour trained supervisors, trained workers and specific work practices (wet methods, prompt clean-up of debris, HEPA vacuums, etc.)

Asbestos Survey Report Page 4

VETERANS ADMINISTRATION

DATE OF SURVEY: FEBRUARY 19, 2018

NESHAP - REGULATED

ASBESTOS-CONTAINING MATERIALS (R-ACM)

1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized or reduced to powder by hand pressure) X Thermal system insulation (TSI)* Textured ceiling material (TCM)* Spray-on insulation or fireproofing* Blown-in insulation* Ceiling tiles/panels* Plaster, gypsum board, gypsum board joint compound* X Cloth materials* (Vibration Isolator) Paper materials* (HVAC Paper Tape and Insulating Board) Electrical wiring insulation* Sink undercoating (loose)* Other*

2. Category I ACM which has become friable

Packings Gaskets (Boiler Rope Gasket) Resilient floor coverings Asphalt roofing products

3. Category I ACM that will be or has been subjected to sanding, grinding, cutting or abrading

Packings Gaskets Resilient floor coverings Asphalt roofing products

4. Category II ACM that has a high probability of becoming or has become friable in the course of demolition or renovation operations Asbestos cement materials (fiber cement ceiling panels)* Asphalt, tar and rubber-base ACM products other than roofing products Non-asphalt and non-paper roofing products* Paint Fire brick and/or mortar* Stainless steel sink undercoating Encapsulated TCM* Encapsulated TSI* Mastic for floor tile, ceiling tile, cove molding, etc.

Other (Exterior Caulk, Window Glaze)

Asbestos Survey Report Page 5

VETERANS ADMINISTRATION

DATE OF SURVEY: FEBRUARY 19, 2018

NESHAP NON-REGULATED

ASBESTOS-CONTAINING MATERIAL (N-R-ACM)

1. > 1% asbestos

2. Category I Non-friable (cannot be crumbled, pulverized, or reduced to powder by hand pressure) ACM with >1% asbestos by new PLM procedure Packings Gaskets X Resilient floor coverings (floor tile) X Asphalt roofing products

3. Category II Non-friable ACM with >1% asbestos by new PLM procedure (Category includes items meeting Category I definition but not specifically listed in that category) X Asbestos cement materials (Transite)* (laboratory counter tops) X Asphalt, tar and rubber-base ACM products other than roofing products* (Caulking, Exterior Wall Black Tar) Non-asphalt and non-paper roofing products* Paint* Fire brick and/or mortar* X Sink undercoating (solid)* X Mastic for floor tile, ceiling tile, cove molding, etc.* Other* (Fire door)

Notes:

1. (*) denotes R & R’s interpretation of materials included in this category.

2. New PLM procedure is outlined in Appendix A, Subpart F, 40 CFR, Part 783, Section 1, Polarized Light

Microscopy.

3. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air Pollutants

(NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature.

Asbestos materials classified as “NON-REGULATED” at the time of the survey may become “REGULATED” due to ongoing or planned maintenance, renovation, or demolition actions, which can transform a material containing greater than 1% asbestos from a “non-friable” and NON-REGULATED to a friable and REGULATED condition. Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.

4. Maintenance, renovation, demolition, weathering, normal wear, water or other damage can alter the “NON-REGULATED” status of materials, and necessitate precautions required for handling them as “REGULATED” asbestos-materials.

Asbestos Survey Report Page 6

3.0 SAMPLING METHODS

Survey procedures were based on those outlined in Title 40 Code of Federal Regulation (CFR) Part 763, USEPA Asbestos Hazard Emergency Response Act, and the Asbestos Model Accreditation Plan (effective April 4, 1994). The procedures included visual observation, physical inspection, bulk sample collection, and condition assessment of suspect ACM. The number of samples collected was based on the amount and accessibility of each homogeneous material, with consideration given for the type, age, and condition.

Two Hundred (200) samples were collected from the suspect materials to assess the presence of asbestos (or lack thereof) in building materials/systems. Each sample collected was placed into a sealable plastic bag or tub, marked with a unique sample identification code, and packaged for subsequent shipment to the laboratory for analysis. Individual sample identification consisted of a numeric code denoting the sampling media/location.

Subsequent to packaging and labeling, samples were submitted under proper chain-of-custody to Reservoirs Environmental, Inc., Denver, Colorado. The National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896 accredits Reservoirs for asbestos analysis.

Samples were analyzed via Polarized Light Microscopy (PLM) utilizing EPA Method 600/M4- 82-020. Please note that USEPA and OSHA regulations define an ACM as a material containing more than one (1) percent asbestos, by volume, as determined by PLM analysis. In the case of multi-layer systems (e.g., floor tile/mastic layers), the laboratory analyzed and reported each layer separately.

4.0 SURVEY RESULTS

Asbestos containing material was identified during this survey. Two hundred (200) representative samples collected were submitted for analytical determination. A summary of analytical results for samples collected and analyzed for this survey are in Appendix B (Laboratory Results).

Photographs illustrating representative asbestos containing media are included as Appendix C.

Asbestos Survey Report Page 7

5.0 CONCLUSIONS

It is our understanding the building will be renovated. ACM was identified during the survey of the facility. See the Executive Summary for specific materials/locations. Friable materials or materials that may become friable during demolition must be removed prior to demolition. Non-friable materials which will not become friable during demolition may remain in the building for demolition. However, if materials remain in the building, OSHA regulations would still apply to these and shall be followed.

6.0 LIMITATIONS AND EXCLUSION OF WARRANTY

This asbestos survey and assessment was performed using procedures and a level of diligence typically exercised by professional consultants performing similar services. However, asbestos-containing material (ACM) can be present in a structure, but not identified using ordinary investigative procedures.

No asbestos survey can completely, eliminate uncertainty regarding the presence of ACM. R & R Environmental, Inc.’s level of diligence and investigative procedures are intended to reduce, but not eliminate, potential uncertainty regarding the presence of ACM. The procedures used for this survey attempt to establish a balance between the competing goals of limiting investigative costs, time, and building damage, and reducing the uncertainty about unknown conditions. Therefore, the determinations in this report should not be construed as a guarantee that all ACM present in the subject property has been included in this report.

This report presents R & R Environmental, Inc.’s professional determinations, which are dependent upon information obtained during performance of consulting services. R & R Environmental, Inc. assumes no responsibility for omissions or errors resulting from inaccurate information provided by sources outside of R & R Environmental, Inc.

No warranty or guarantee, expressed or implied, is made regarding the findings, conclusions, or recommendations contained in this report. The limitations presented above supersede the requirements or provisions of all other contracts or scopes of work, implied, or otherwise, except stated or acknowledged herein.

Asbestos Survey Report Page 8

ASBESTOS SURVEY AND ASSESSMENT

OF THE

VETERANS ADMINISTRATION MEDICAL CENTER

660-15-121, BUILDING 2, ZONES A, B, AND C

During the month of March 2018, R & R Environmental, Inc. (R & R) of Sandy, Utah, conducted an asbestos survey and assessment for Veterans Administration Hospital. Bulk samples of suspect asbestos-containing materials were collected and analyzed. The condition of all friable and non-friable asbestos-containing materials were assessed. The following accredited inspector conducted the survey and assessment.

Inspected by:

April 20, 2018 Steven B. Smith State of Utah, Inspector Certification Number: ASB-3274 State of Utah Company Certification: ASBC-237

Reviewed by:

April 20, 2018 David C. Roskelley, MSPH, CIH, CSP State of Utah, Inspector Certification Number: ASB-1370 AHERA Inspector #5 PSI 65451 I Certified Safety Professional #15774 Certified Industrial Hygienist #8529

Appendix A

Sample Log

SAMPLE LOG

Sample #

Material

Sample Location / Quantity

Lab Result (%/Type)

Photo

Assumed

ACM

(Yes/No)

Assessment VA-02-27-18-001 Black Flooring Mastic Room GA13 / 6,220 ft2 7% Chrysotile 4, 5 No Undamaged VA-02-27-18-002 Black Flooring Mastic Room 1A05 / 6,220 ft2 7% Chrysotile 4, 5 No Undamaged VA-02-27-18-003 Black Flooring Mastic Room 2C01 / 6,220 ft2 7% Chrysotile 4, 5 No Undamaged VA-02-27-18-004 12” Vinyl Floor Tile – Gray with Brown & Mastic

Room GA00 / 19,827 ft2 4% Chrysotile (tile) 7% Chrysotile (mastic)

2, No Undamaged

VA-02-27-18-005 12” Vinyl Floor Tile – Gray with Brown & Mastic

Room 1A28 / 19,827 ft2 None Detected (tile) 7% Chrysotile (mastic)

2 No Undamaged

VA-02-27-18-006 12” Vinyl Floor Tile – Gray with Brown & Mastic

Room 2A14 / 19,827 ft2 None Detected 2 No Undamaged

VA-02-27-18-007 12” Vinyl Floor Tile – Tan with Brown & Mastic

Room GA19B / 4,152 ft2 4% Chrysotile (tile) 7% Chrysotile (mastic)

3 No Undamaged

VA-02-27-18-008 12” Vinyl Floor Tile – Tan with Brown & Mastic

Room GA15 / 4,152 ft2 None Detected (tile) 7% Chrysotile (mastic)

3 No Undamaged

VA-02-27-18-009 12” Vinyl Floor Tile – Tan with Brown & Mastic

Room 2A19B / 4,152 ft2 None Detected (tile) 6% Chrysotile (mastic)

3 No Undamaged

VA-02-27-18-010 12” Vinyl Floor Tile – Tan with Blue with Brown & Mastic

Room GA36 / 1,871 ft² None Detected (tile) 7% Chrysotile (mastic)

- No Undamaged

VA-02-27-18-011 12” Vinyl Floor Tile – Tan with Blue with Brown & Mastic

Room 1A33 / 1,871 ft² None Detected - No Undamaged

VA-02-27-18-012 12” Vinyl Floor Tile – Tan with Blue with Brown & Mastic

Room 1A22 / 1,871 ft² None Detected (tile) 7% Chrysotile (mastic)

- No Undamaged

VA-02-27-18-013 12” Vinyl Floor Tile – White with Blue & Mastic

Room 1A03A / 398 ft² None Detected (tile) 7% Chrysotile (mastic)

- No Undamaged

Assumed

VA-02-27-18-014 12” Vinyl Floor Tile –

White with Blue & Mastic

Room 1A13 / 398 ft² None Detected (tile) 7% Chrysotile (mastic)

- No Undamaged

VA-02-27-18-015 12” Vinyl Floor Tile – White with Blue & Mastic

Room 1C00 / 398 ft² None Detected

VA-02-27-18-016 Rolled Vinyl Flooring – Cream with Pink & Blue

Room GA22 / 1,182 ft² None Detected

VA-02-27-18-017 Rolled Vinyl Flooring – Cream with Pink & Blue

Room 1A08 / 1,182 ft² None Detected

VA-02-27-18-018 Rolled Vinyl Flooring – Cream with Pink & Blue

Room 1A29 / 1,182 ft² None Detected - No Undamaged

VA-02-27-18-019 Rolled Vinyl Flooring - White

Room GC05 / 293 ft² None Detected - No Undamaged

VA-02-27-18-020 Rolled Vinyl Flooring - White

Room GC07A / 293 ft² None Detected - No Undamaged

VA-02-27-18-021 Rolled Vinyl Flooring - White

Room GC05 / 293 ft² None Detected - No Undamaged

VA-02-27-18-022 Rolled Vinyl Flooring – Tan with Flecks

Room GA06 / 481 ft² None Detected - No Undamaged

VA-02-27-18-023 Rolled Vinyl Flooring – Tan with Flecks

Room 2A29 / 481 ft² None Detected - No Undamaged

VA-02-27-18-024 Rolled Vinyl Flooring – Tan with Flecks

Room 2A08 / 481 ft² None Detected - No Undamaged

VA-02-27-18-025 Rolled Vinyl Flooring - Gray

Room 2A27 / 433 ft² 8% Chrysotile (mastic)

- No Undamaged

VA-02-27-18-026 Rolled Vinyl Flooring - Gray

Room 2A27 / 433 ft² 7% Chrysotile (mastic)

- No Undamaged

VA-02-27-18-027 Rolled Vinyl Flooring - Gray

Room 2A27 / 433 ft² None Detected - No Undamaged

VA-02-27-18-028 Vinyl Cove Base – Dark Brown & Mastic

Room GA18 / 3,346 lf None Detected - No Undamaged

VA-02-27-18-029 Vinyl Cove Base – Dark Brown

Room 1A34 / 3,346 lf None Detected - No Undamaged

Assumed

VA-02-27-18-030 Vinyl Cove Base – Dark

Brown & Mastic

Room 2A14 / 3,346 lf None Detected - No Undamaged

VA-02-27-18-031 Vinyl Cove Base – Dark Blue & Mastic

Room 1A25 / 160 lf None Detected - No Undamaged

VA-02-27-18-032 Vinyl Cove Base – Dark Blue & Mastic

Room 1A27 / 160 lf None Detected - No Undamaged

VA-02-27-18-033 Vinyl Cove Base – Dark Blue & Mastic

Room 1A27 / 160 lf None Detected - No Undamaged

VA-02-27-18-034 Vinyl Cove Base – Dark Tan & Mastic

Room 1A00 / 562 lf None Detected - No Undamaged

VA-02-27-18-035 Vinyl Cove Base – Dark Tan & Mastic

Room 1A00 / 562 lf None Detected - No Undamaged

VA-02-27-18-036 Vinyl Cove Base – Dark Tan & Mastic

Room 2A02 / 562 lf None Detected - No Undamaged

VA-02-27-18-037 Vinyl Cove Base – Gray & Mastic

Room GAA / 512 lf None Detected - No Undamaged

VA-02-27-18-038 Vinyl Cove Base – Gray & Mastic

Room 1A05 / 512 lf None Detected - No Undamaged

VA-02-27-18-039 Vinyl Cove Base – Gray & Mastic

Room 2C01 / 512 lf None Detected - No Undamaged

VA-02-27-18-040 Vinyl Cove Base – Red & Mastic

Room GB00 / 158 lf None Detected - No Undamaged

VA-02-27-18-041 Vinyl Cove Base – Red

Room GB09 / 158 lf None Detected

VA-02-27-18-042 Vinyl Cove Base – Red & Mastic

Room GB09B / 158 lf None Detected - No Undamaged

VA-02-27-18-043 Vinyl Cove Base – Light Tan

Room 1A03 / 770 lf None Detected

Assumed

VA-02-27-18-044 Vinyl Cove Base – Light

Tan & Mastic

Room GA21A / 770 lf None Detected - No Undamaged

VA-02-27-18-045 Vinyl Cove Base – Light Tan & Mastic

Room GA25H / 770 lf None Detected - No Undamaged

VA-02-27-18-046 Vinyl Stair Tread – Green & Mastic

Room GAAA / 315 ft² None Detected - No Undamaged

VA-02-27-18-047 Vinyl Stair Tread – Green & Mastic

Room 1AAA / 315 ft² None Detected - No Undamaged

VA-02-27-18-048 Vinyl Stair Tread – Green & Mastic

Room GAAA / 315 ft² None Detected - No Undamaged

VA-02-27-18-049 Vinyl Stair Tread – Red & Mastic

Room GBA / 315 ft² None Detected - No Undamaged

VA-02-27-18-050 Vinyl Stair Tread – Red & Mastic

Room GBA / 315 ft² None Detected - No Undamaged

VA-02-27-18-051 Vinyl Stair Tread – Red & Mastic

Room GBA / 315 ft² None Detected - No Undamaged

VA-02-27-18-052 Mastic under Ceramic Tile with Mortar – Yellow

Room 1A45B / 310 ft² 7% Chrysotile (mastic)

4,5 No Undamaged

VA-02-27-18-053 Leveling Compound under Ceramic Tile with Mortar – Brown & Tan

Room GA15A / 214 ft² Trace Chrysotile (Gray Leveling Compound)

19 No Undamaged

VA-02-27-18-054 Ceramic Tile with Mortar – Green

Room 2C06A / 105 ft² None Detected - No Undamaged

VA-02-27-18-055 2” Ceramic Tile with Mortar - White

Room 1B04 / 275 ft² None Detected - No Undamaged

VA-02-27-18-056 2” Ceramic Tile with Mortar – Brown

Room GB09A / 165 ft² None Detected - No Undamaged

VA-02-27-18-057 2’ x 4’ Ceiling Panel #1 Room GA25 / 6,850 ft² None Detected - No Undamaged VA-02-27-18-058 2’ x 4’ Ceiling Panel #1 Room GA25 / 6,850 ft² None Detected - No Undamaged VA-02-27-18-059 2’ x 4’ Ceiling Panel #1 Room GA21 / 6,850 ft² None Detected - No Undamaged VA-02-27-18-060 2’ x 4’ Ceiling Panel #4 Room 1A00/ 7,200 ft² None Detected - No Undamaged VA-02-27-18-061 2’ x 4’ Ceiling Panel #4 Room 1A00/ 7,200 ft² None Detected - No Undamaged VA-02-27-18-062 2’ x 4’ Ceiling Panel #4 Room 1A00 / 7,200 ft² None Detected - No Undamaged

Assumed

VA-02-27-18-063 2’ x 4’ Ceiling Panel #4 Room 2A00 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-064 2’ x 4’ Ceiling Panel #4 Room 2A00 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-065 2’ x 4’ Ceiling Panel #4 Room 2A00 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-066 2’ x 4’ Ceiling Panel #2 Room GA25D / 250 ft² None Detected - No Undamaged VA-02-27-18-067 2’ x 4’ Ceiling Panel #2 Room GA25D / 250 ft² None Detected - No Undamaged VA-02-27-18-068 2’ x 4’ Ceiling Panel #2 Room GA25D / 250 ft² None Detected - No Undamaged VA-02-27-18-069 2’ x 4’ Ceiling Panel #3 Room GA19A / 150 ft² None Detected - No Undamaged VA-02-27-18-070 2’ x 4’ Ceiling Panel #3 Room GA19A / 150 ft² None Detected - No Undamaged VA-02-27-18-071 2’ x 4’ Ceiling Panel #3 Room GA19A / 150 ft² None Detected - No Undamaged VA-02-27-18-072 2’ x 4’ Ceiling Panel #4 Room 2C03 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-073 2’ x 4’ Ceiling Panel #4 Room 2C03 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-074 2’ x 4’ Ceiling Panel #4 Room 2B06 / 7,200 ft² None Detected - No Undamaged VA-02-27-18-075 2’ x 2’ Ceiling Panel #1 Room GA00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-076 2’ x 2’ Ceiling Panel #1 Room GA00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-077 2’ x 2’ Ceiling Panel #1 Room GA00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-078 2’ x 2’ Ceiling Panel #1 Room 1A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-079 2’ x 2’ Ceiling Panel #1 Room 1A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-080 2’ x 2’ Ceiling Panel #1 Room 1A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-081 2’ x 2’ Ceiling Panel #1 Room 2A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-082 2’ x 2’ Ceiling Panel #1 Room 2A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-083 2’ x 2’ Ceiling Panel #1 Room 2A00 / 12,834 ft² None Detected - No Undamaged VA-02-27-18-084 2’ x 2’ Ceiling Panel #2 Room GA19 / 24 ft² None Detected - No Undamaged VA-02-27-18-085 2’ x 2’ Ceiling Panel #2 Room GA19 / 24 ft² None Detected - No Undamaged VA-02-27-18-086 2’ x 2’ Ceiling Panel #2 Room GA19 / 24 ft² None Detected - No Undamaged VA-02-27-18-087 2’ x 2’ Ceiling Panel #3 Room 2A34 / 130 ft² None Detected - No Undamaged VA-02-27-18-088 2’ x 2’ Ceiling Panel #3 Room 2A34 / 130 ft² None Detected - No Undamaged VA-02-27-18-089 2’ x 2’ Ceiling Panel #3 Room 2A38 / 130 ft² None Detected - No Undamaged VA-02-27-18-090 12” Ceiling Tile #1 Room GA25G / 430 ft² None Detected - No Undamaged VA-02-27-18-091 12” Ceiling Tile #1 Room GA25G / 430 ft² None Detected - No Undamaged VA-02-27-18-092 12” Ceiling Tile #1 Room 1C08 / 430 ft² None Detected - No Undamaged

Assumed

VA-02-27-18-093 12” Ceiling Tile #2 Room GA25H/ 41 ft² None Detected - No Undamaged VA-02-27-18-094 12” Ceiling Tile #2 Room GA25H/ 41 ft² None Detected - No Undamaged VA-02-27-18-095 12” Ceiling Tile #2 Room GA25H/ 41 ft² None Detected - No Undamaged VA-02-27-18-096 Firewall Cement Patch Room GA00 / 1,240 ft² None Detected - No Undamaged VA-02-27-18-097 Firewall Cement Patch Room GA00 / 1,240 ft² None Detected - No Undamaged VA-02-27-18-098 Firewall Cement Patch Room 1C06 / 1,240 ft² None Detected - No Undamaged VA-02-27-18-099 Plaster Surfacing Room GA25 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-100 Plaster Surfacing Room GA00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-101 Plaster Surfacing Room GA00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-102 Plaster Surfacing Room 1B00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-103 Plaster Surfacing Room 1A00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-104 Plaster Surfacing Room 1A00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-105 Plaster Surfacing Room 2A00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-106 Plaster Surfacing Room 2A00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-107 Plaster Surfacing Room 2A00 / >15,000 ft² None Detected - No Undamaged VA-02-27-18-108 Wall System Room GA25E / >5,000 ft² Overall <1%

Chrysotile (By Point Count)

20 No Undamaged

VA-02-27-18-109 Wall System Room GA02 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-110 Wall System Room GA24 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-111 Wall System Room 1A53 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-112 Wall System Room 1B05 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-113 Wall System Room 1C05 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-114 Wall System Room 2A27 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-115 Wall System Room 2A23 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-116 Wall System Room 2A12 / >5,000 ft² None Detected - No Undamaged VA-02-27-18-117 HVAC Vibration Isolator

(Canvas) Room 1A09 / 360 lf None Detected - No Undamaged

VA-02-27-18-118 HVAC Vibration Isolator (Canvas)

Room GA36 / 360 lf None Detected - No Undamaged

VA-02-27-18-119 HVAC Vibration Isolator (Canvas)

Room GA25A / 360 lf None Detected - No Undamaged

Assumed

VA-02-27-18-120 Paper Duct Tape Room GA25A / 532 lf None Detected - No Undamaged VA-02-27-18-121 Ceiling Tile Adhesive Room GA25H / 2,200 ft² None Detected - No Undamaged VA-02-27-18-122 Ceiling Tile Adhesive Room GA36 / 2,200 ft² None Detected - No Undamaged VA-02-27-18-123 Ceiling Tile Adhesive Room 1A21 / 2,200 ft² None Detected - No Undamaged VA-02-27-18-124 Duct Sealant – Tan Room GA36 / 6,240 ft² None Detected - No Undamaged VA-02-27-18-125 Duct Sealant – White Room 1C00 / 2,280 ft² None Detected - No Undamaged VA-02-27-18-126 Radiator Fiberboard Room GA36 / 4,150 ft² None Detected - No Undamaged VA-02-27-18-127 Black Tar Cork Wrap Room GA00 / 2,600 ft² None Detected - No Undamaged VA-02-27-18-128 Black Tar Cork Wrap Room 1C00 / 2,600 ft² None Detected - No Undamaged VA-02-27-18-129 Black Tar Cork Wrap Room 1C00 / 2,600 ft² None Detected - No Undamaged VA-02-27-18-130 Tunnel Ceiling Damp

Proofing Tunnel / 1,265 ft² None Detected - No Undamaged

VA-02-27-18-131 Tunnel Ceiling Damp Proofing

Tunnel / 1,265 ft² None Detected - No Undamaged

VA-02-27-18-132 Tunnel Ceiling Damp Proofing

Tunnel / 1,265 ft² None Detected - No Undamaged

VA-02-27-18-133 Lab Counter Top Material – Black

Room GA04 / 164 ft² None Detected - No Undamaged

VA-02-27-18-134 Lab Counter Top Material – Salmon

Room GA22 / 310 ft² None Detected - No Undamaged

VA-02-27-18-135 Lab Counter Top Material – Salmon

Room GA22 / 310 ft² None Detected - No Undamaged

VA-02-27-18-136 Lab Counter Top Material – Salmon

Room GA24 / 310 ft² None Detected - No Undamaged

VA-02-27-18-137 TSI – End Sealant Room GB07 / 2,850 ft² None Detected - No Undamaged VA-02-27-18-138 TSI – End Sealant Room 2A23 / 2,850 ft² None Detected - No Undamaged VA-02-27-18-139 TSI – End Sealant Penthouse / 2,850 ft² None Detected - No Undamaged VA-02-27-18-140 Red Fire Stop Putty Room GB01 / 840 ft² None Detected - No Undamaged VA-02-27-18-141 Red Fire Stop Putty Room GA26 / 840 ft² None Detected - No Undamaged VA-02-27-18-142 Red Fire Stop Putty Room 2B05 / 840 ft² None Detected - No Undamaged VA-02-27-18-143 Fire Door Insulation –

White Plaster GB00 / 212 each None Detected - No Damaged

VA-02-27-18-144 HVAC Vibration Isolator – Black

Room 1B03 / 410 lf None Detected - No Undamaged

Assumed

VA-02-27-18-145 Metal Access Fire Door Room GA34A / 6 each None Detected - No Undamaged VA-02-27-18-146 Insulation Tab Adhesive Room GA26 / 150 ft² 28% Chrysotile 15 No Undamaged VA-02-27-18-147 12” Ceiling Tile #3 Room GA25H / 193 ft² None Detected - No Undamaged VA-02-27-18-148 12” Ceiling Tile #3 Room GA25H / 193 ft² None Detected - No Undamaged VA-02-27-18-149 12” Ceiling Tile #3 Room 2B09 / 193 ft² None Detected - No Undamaged VA-02-27-18-150 12” Ceiling Tile #4 Room 2A07 / 14 ft² None Detected - No Undamaged VA-02-27-18-151 CMU Block Filler Room GB05 / 3,800 ft² None Detected - No Undamaged VA-02-27-18-152 CMU Block Filler Room GB05 / 3,800 ft² None Detected - No Undamaged VA-02-27-18-153 CMU Block Filler Room GB09 / 3,800 ft² None Detected - No Undamaged VA-02-27-18-154 CMU Block Filler Room GB09 / 3,800 ft² None Detected - No Undamaged VA-02-27-18-155 CMU Block Filler Room GB09 / 3,800 ft² None Detected - No Undamaged VA-02-27-18-156 Blue Fire Stop Putty Room GB01 / 65 ft² None Detected - No Undamaged VA-02-27-18-157 Spray on Fire-Proofing Room GB09 / 1,598 ft² None Detected - No Undamaged VA-02-27-18-158 Spray on Fire-Proofing Room GB09 / 1,598 ft² None Detected - No Undamaged VA-02-27-18-159 Spray on Fire-Proofing Room GB09 / 1,598 ft² None Detected - No Undamaged VA-02-27-18-160 Spray on Fire-Proofing Room GB09 / 1,598 ft² None Detected - No Undamaged VA-02-27-18-161 Spray on Fire-Proofing Room GB09 / 1,598 ft² None Detected - No Undamaged VA-02-27-18-162 HVAC Vibration Isolator Room GC03 / 12 lf 85% Chrysotile 16 No Damaged VA-02-27-18-163 Thermal Systems Insulation

– Tank Cap Room GC03 / 58 ft² None Detected - No Undamaged

VA-02-27-18-164 Thermal Systems Insulation

– Tank Cap

Room GC03 / 58 ft² None Detected - No Undamaged

VA-02-27-18-165 Thermal Systems Insulation

– Tank Cap

Room GC03 / 58 ft² None Detected - No Undamaged

VA-02-27-18-166 Conduit Fill Putty Room GC03 / 3 ft² None Detected - No Undamaged VA-02-27-18-167 Sink Undercoating – Gray Room 1A33 / 3 each None Detected - No Undamaged VA-02-27-18-168 Sink Undercoating – Gray Room 1A22 / 3 each None Detected - No Undamaged VA-02-27-18-169 Sink Undercoating – Gray Room 2B01 / 3 each None Detected - No Undamaged VA-02-27-18-170 Thermal Systems Insulation

– Lagging Jacket Material Room GA00 / 6,240 lf None Detected - No Undamaged

VA-02-27-18-171 Thermal Systems Insulation

– Lagging Jacket Material

Room 1A00 / 6,240 lf None Detected - No Undamaged

Assumed

VA-02-27-18-172 Black Sealant Room 2B01 / 40 ft² None Detected - No Undamaged VA-02-27-18-173 Thermal Systems Insulation

– Lagging Jacket Material Room 2A00 / 6,240 lf None Detected - No Undamaged

VA-02-27-18-174 Black Roofing Tar Penthouse / 1,200 ft² 9% Chrysotile 17 No Undamaged VA-02-27-18-175 Black Roofing Tar Penthouse / 1,200 ft² 9% Chrysotile 17 No Undamaged VA-02-27-18-176 Black Roofing Tar Penthouse / 1,200 ft² 11% Chrysotile 17 No Undamaged VA-02-27-18-177 White Roofing Sealant Roof / 150 ft² None Detected - No Undamaged VA-02-27-18-178 White Roofing Sealant Roof / 150 ft² None Detected - No Undamaged VA-02-27-18-179 White Roofing Sealant Roof / 150 ft² None Detected - No Undamaged VA-02-27-18-180 Caulking Penthouse / 120 ft² None Detected - No Undamaged VA-02-27-18-181 Black Fiberglass Lagging

Adhesive GA00 / 6,240 lf None Detected - No Undamaged

VA-02-27-18-182 Brown Vinyl Elevator Flooring

North Elevator/ 100 ft² None Detected - No Undamaged

VA-02-27-18-183 Tan Vinyl Elevator Flooring

North Elevator / 100 ft² None Detected - No Undamaged

VA-02-27-18-184 Tan Vinyl Elevator Flooring

South Elevator / 100 ft² None Detected - No Undamaged

VA-02-27-18-185 Blue Vinyl Elevator Flooring

South Elevator / 100 ft² None Detected - No Undamaged

VA-02-27-18-186 Thermal Systems Insulation

– End Sealant

Room GC03 / 2,850 ft² None Detected - No Undamaged

VA-02-27-18-187 Thermal Systems Insulation

– End Sealant

Room GC03 / 2,850 ft² None Detected - No Undamaged

VA-02-27-18-188 Thermal Systems Insulation

– End Sealant

Room GC03 / 2,850 ft² None Detected - No Undamaged

VA-02-27-18-189 Caulking Penthouse / 120 ft² 12% Chrysotile 18 No Undamaged VA-02-27-18-190 Caulking Penthouse/ 120 ft² None Detected - No Undamaged VA-02-27-18-191 Drinking Fountain Water

Line Insulation Room 2A00 / 6,240 ft² None Detected - No Undamaged

VA-02-27-18-192 Ceramic Tile – Brown & Mortar

Room 1A11 / 198 ft² None Detected - No Undamaged

VA-02-27-18-193 2’ x 2’ Ceiling Panel #1 Room 1A28 / 1,032 ft² None Detected - No Undamaged VA-02-27-18-194 2’ x 2’ Ceiling Panel #1 Room 1A24 / 1,032 ft² None Detected - No Undamaged VA-02-27-18-195 2’ x 2’ Ceiling Panel #1 Room 1A30 / 1,032 ft² None Detected - No Undamaged

Assumed

VA-02-27-18-196 2’ x 4’ Ceiling Panel #5 Room 1A19 / 1,201 ft² None Detected - No Undamaged VA-02-27-18-197 2’ x 4’ Ceiling Panel #5 Room 1A21 / 1,201 ft² None Detected - No Undamaged VA-02-27-18-198 2’ x 4’ Ceiling Panel #5 Room 1A23 / 1,201 ft² None Detected - No Undamaged VA-02-27-18-199 2’ x 4’ Ceiling Panel #6 Room 1A24/ 48 ft² None Detected - No Undamaged VA-02-27-18-200 2’ x 4’ Ceiling Panel #7 Room 1A24/ 56 ft² None Detected - No Undamaged

Appendix B

Laboratory Report

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

Subcontract Number: NA

Laboratory Report: RES 402517-1

Project # / P.O. # None Given

Project Description: VA Building 2 - A Zone, B Zone and C Zone

RES 402517-1

Sincerely, is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed.

This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the

U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs

Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.

Jeanne Spencer

President

March 12, 2018

Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and

Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American

Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast

Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.

Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.

R & R Environmental

47 West 9000 South #2

Sandy UT 84070

Steve Smith

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

1-866-RESI-ENV

www.reilab.com

RES Job Number:

Client:

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-001 EM 2036765 Gray granular cementitious debrisA 5 ND 1000Colorless adhesiveB 20 ND 1000Tan masticC 35 ND

930Black masticD 40 7 Chrysotile 1000VA-022718-002 EM 2036766 Tan masticA 5 ND

930Black masticB 95 7 Chrysotile 930VA-022718-003 EM 2036767 Black masticA 100 7 Chrysotile 930VA-022718-004 EM 2036768 Black masticA 4 7 Chrysotile 960Light gray/tan tileB 96 4 Chrysotile 930VA-022718-005 EM 2036769 Black masticA 3 7 Chrysotile

1000Blue resinous materialB 5 ND 955Light gray tileC 92 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-006 EM 2036770 Yellow masticA TR ND 1000Off white compoundB 2 ND

955Light gray/tan tileC 98 ND 930VA-022718-007 EM 2036771 Black masticA 15 7 Chrysotile 960Light gray/tan tileB 85 4 Chrysotile

1000VA-022718-008 EM 2036772 Yellow mastic adhesiveA 1 ND 1000Off white compoundB 2 ND

930Black masticC 2 7 Chrysotile 1000Light gray/tan tileD 95 ND 1000VA-022718-009 EM 2036773 Tan masticA 2 ND

940Black masticB 3 6 Chrysotile 1000Off white leveling compoundC 5 ND 1000Light gray/tan tileD 90 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

930VA-022718-010 EM 2036774 Black masticA 2 7 Chrysotile 1000Tan masticB 3 ND 1000Off white leveling compoundC 5 ND 100TRLight gray tileD 90 ND 1000VA-022718-011 EM 2036775 Tan multi-layered paintA 2 ND 1000Brown/yellow masticB 4 ND 1000Off white/multi-colored tileC 94 ND

930VA-022718-012 EM 2036776 Black masticA 2 7 Chrysotile 1000Yellow masticB 3 ND 1000Off white/multi-colored tileC 95 ND 1000VA-022718-013 EM 2036777 Blue resinous materialA TR ND 1000Yellow masticB TR ND

930Black masticC 1 7 Chrysotile 1000Off white/multi-colored tileD 99 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-014 EM 2036778 Yellow adhesiveA 1 ND 930Black masticB 4 7 Chrysotile

1000Light gray tileC 95 ND 1000VA-022718-015 EM 2036779 Tan adhesiveA TR ND 1000Light tan compoundB 5 ND 1000Light gray tileC 95 ND 1000VA-022718-016 EM 2036780 Yellow adhesiveA 1 ND 1000Light gray/multi-colored tileB 99 ND 1000VA-022718-017 EM 2036781 Off white leveling compoundA 2 ND 1000Tan masticB 3 ND 1000Light gray/multi-colored tileC 95 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-018 EM 2036782 Off white masticA TR ND 1000Gray resinous materialB 1 ND 1000White leveling compoundC 3 ND 1000Tan masticD 3 ND 1000Off white/multi-colored tileE 93 ND 1000VA-022718-019 EM 2036783 Gray resinous materialA TR ND 1000Tan masticB TR ND 1000Light gray/multi-colored tileC 100 ND

9010VA-022718-020 EM 2036784 Gray resinous leveling compoundA TR ND 1000Clear adhesiveB 1 ND 100TRLight gray/multi-colored tileC 99 ND 1000VA-022718-021 EM 2036785 Tan adhesiveA 2 ND 100TRLight gray/multi-colored tileB 98 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-022 EM 2036786 Clear adhesiveA 2 ND 1000Off white/multi-colored tileB 98 ND 1000VA-022718-023 EM 2036787 Tan masticA TR ND

8317Gray/multi-colored sheet vinyl w/ light tan fibrous backing material

B 100 ND

1000VA-022718-024 EM 2036788 Off white/multi-colored tileA 100 ND 920VA-022718-025 EM 2036789 Black masticA 4 8 Chrysotile

1000Light gray/white tileB 96 ND 1000VA-022718-026 EM 2036790 Off white masticA TR ND 1000Light gray/white tileB 100 ND

930VA-022718-027 EM 2036791 Black masticA 2 7 Chrysotile 1000Tan masticB 2 ND 1000Light gray/white tileC 96 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-028 EM 2036792 Tan masticA 1 ND 1000Brown cove baseB 99 ND 1000VA-022718-029 EM 2036793 Tan masticA 2 ND 1000Brown cove baseB 98 ND 1000VA-022718-030 EM 2036794 Tan masticA 1 ND 1000Brown cove baseB 99 ND 1000VA-022718-031 EM 2036795 Tan masticA 2 ND 1000Blue cove baseB 98 ND 1000VA-022718-032 EM 2036796 Clear resinous materialA 1 ND 1000Light tan masticB 5 ND 1000Dark blue cove baseC 94 ND 1000VA-022718-033 EM 2036797 Light tan masticA 1 ND 1000Dark blue cove baseB 99 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-034 EM 2036798 Light tan masticA 4 ND 1000Light brown cove baseB 96 ND 1000VA-022718-035 EM 2036799 Light tan masticA 3 ND 1000Light brown cove baseB 97 ND 1000VA-022718-036 EM 2036800 Brown masticA 3 ND 1000Off white masticB 5 ND 1000Light brown cove baseC 92 ND 1000VA-022718-037 EM 2036801 Off white compoundA 5 ND 1000Tan masticB 5 ND 1000Gray cove baseC 90 ND 1000VA-022718-038 EM 2036802 Gray resinous materialA 1 ND 1000Orange resinous materialB 2 ND 1000Light tan masticC 4 ND 1000Gray cove baseD 93 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-039 EM 2036803 Tan masticA 2 ND 1000Gray cove baseB 98 ND 1000VA-022718-040 EM 2036804 Brownish-red cove baseA 100 ND 1000VA-022718-041 EM 2036805 Off white masticA TR ND 1000Brownish-red cove baseB 100 ND 1000VA-022718-042 EM 2036806 Off white masticA 3 ND 1000Brownish-red cove baseB 97 ND 1000VA-022718-043 EM 2036807 Off white compoundA 1 ND 1000Off white masticB 2 ND 1000Gray cove baseC 97 ND

991VA-022718-044 EM 2036808 Brown masticA 3 ND 1000Brown cove base w/ gray paintB 97 ND 1000VA-022718-045 EM 2036809 Tan soilA 4 ND 1000Light brown cove baseB 96 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

1000VA-022718-046 EM 2036810 Tan masticA 5 ND 1000Light green cove baseB 95 ND 1000VA-022718-047 EM 2036811 Tan masticA 3 ND 1000Light green cove baseB 97 ND 1000VA-022718-048 EM 2036812 Tan masticA 4 ND 1000Light green cove baseB 96 ND 1000VA-022718-049 EM 2036813 Tan masticA 8 ND 1000Brown cove baseB 92 ND 1000VA-022718-050 EM 2036814 Tan masticA 5 ND 1000Brown cove baseB 95 ND 1000VA-022718-051 EM 2036815 Tan masticA 5 ND 1000Brown cove baseB 95 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 402517-1

R & R Environmental None Given VA Building 2 - A Zone, B Zone and C Zone March 05, 2018

3-5 Day March 12, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservo…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .