LIMIT OF GPR SURVEY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
GI001
GENERAL INDEX
A
DESIGN DEVELOPMENT
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Building C Demolish & Replace with Parking
1055 Clermont St., Denver, CO, 80220
554-17-112
C Project Director
DaveyRevisions: Date:
C U se rs
VH
A
EC
H G ill eD
D es kt op
4-
D ra w in gs .d w g
:0 4:
P M
VH
A
EC
H G ill eD
Demolish Building C & Replace with Parking
ARCHITECTURE ENGINEERING CONSTRUCTION
PROJECT 554-17-112
VA PROJECT TEAM
OWNER OWNER'S CONTRACTING OFFICER
VISN 19 CONTRACTING OFFICER
ROCKY MOUNTAIN CONSOLIDATED CO.
4100 E. MISSISSIPPI AVE, SUITE 900
GLENDALE, CO 80248
DESIGN INTENT
FMS
MARK BLEHM
PH:303.399.8020 EXT. 3786
VETERANS AFFAIRS
VA ECHS MEDICAL CENTER
1055 CLERMONT STREET
DENVER, CO 80220-3808
PHASING
ALL WORK WILL BE PHASED AND APPROVED BY COR AND VA PERSONNEL.
WORK TO TAKE PLACE DURING BUSINESS HOURS. IF WORK CAN NOT BE
COMPLETED DURING BUSINESS HOURS WORK WILL BE SCHEDULED AT NIGHT
OR ON WEEKENDS. CONTRACTOR TO COORDINATE EACH TASK AND PHASE
WITH COR AND STAFF TWO (2) WEEKS IN ADVANCE.
INDEX OF DRAWINGS
DRAWING TITLEDWG NO.
GENERAL INDEX 1 OF 3
SHEET OF #
GI001
SITE PLAN LOCATION DETAIL
STAGING
AREA
CONSTRUCTION
FENCE
AREA OF
DEMOLITION
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
DEMOLITION PLANCD001
PAVING PLANCP001
IF APPLICABLE:
HOT WORK PERMITS.
PERMITS MUST BE OBTAINED 24 HOURS PRIOR TO COMMENCEMENT
OF WORK, WHENEVER POSSIBLE. ORIGINAL PERMIT TO BE POSTED
WHERE WORK IS BEING PERFORMED; CONTRACTOR MUST RETURN
PERMIT TO SAFETY OFFICE WHEN WORK IS COMPLETED.
FIRE WATCH. CONTRACTOR MUST INITIAL, DATE AND TIME EVERY 30
MINUTES AFTER HOT WORK HAS STARTED.
SPRINKLER WORK. CONTRACTOR TO OBTAIN HOT WORK PERMIT
PRIOR TO ANY WORK CONSISTING OF CUTTING, WELDING, SOLDERING,
BRAZING, ETC IS PERFORMED OR WHEN SPRINKLER SYSTEM IS
COMPROMISED FOR MORE THAN FOUR (4) HOURS.
CONTRACTOR TO PROVIDE WARNING SIGNAGE AND DIRECTIONAL
SIGNAGE THAT SHALL BE POSTED IN CONSTRUCTION AREA WHILE
WORK IS PERFORMED.
CONFINED SPACE. CONTRACTOR TO OBTAIN CONFINED SPACE
PERMIT PRIOR TO ENTRY INTO MECHANICAL CHASE. ENSURE IT IS
APPROVED BY VA SAFETY DEPARTMENT AND COR.
INTERIM LIFE SAFETY MEASURES (ILSM)
CONTRACTOR
ACCESS PATH
STAGING
AREA
LIMIT OF GPR SURVEY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
CD101
DEMOLITION PLAN
A
Fi le P at h
DESIGN DEVELOPMENT
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1055 Clermont St., Denver, CO, 80220
554-17-112
C Project Director
Issue date Chkd By Drwn ByRevisions: Date:
GENERAL NOTES
KEY NOTES
GRAPHIC KEY
Demolish Building C & Replace with Parking
1. TERMINATE TELE-COMM CABLE AT MANHOLE. LEAVE CONDUIT IN PLACE.
2. COORDINATE GAS SERVICE REMOVAL WITH UTILITY.
3. CUT AND CAP WATER AT LOCATION SHOWN. REMOVE ABANDONED PIPE.
4. REMOVE TELE-COMM CABLE LEADING TO BLDG 4. REMOVE ABANDONED CONDUIT.
5. CUT AND CAP SANITARY SEWER AT MANHOLE.
6. REMOVE LOW VOLTAGE POWER CABLE BACK TO TRANSFORMER, TR8.
7. REMOVE EXISTING CHILLER, CONCRETE PAD, FENCE, PAD TRANSFORMER, UNDERGROUND
ELECTRICAL, AND UNDERGROUND PIPING.
8. REMOVE CURB SECTION FOR NEW ROAD.
9. REMOVE HANDICAP RAMP.
10. TERMINATE FIRE ALARM WIRING AT JUNCTION BOX IN BUILDING 4. REMOVE ABANDONED
CONDUIT AND WIRE.
DEMOLITION AREA
DEMO PLAN
1. Contractor shall conduct GPR survey to verify all existing conditions and layouts prior to demolition. Notify COR of deviations.
2. Contractor shall use necessary means to protect all items not designated for removal and shall provide appropriate dust control. Coordinate location of dust containment with COR prior to initiating demolition work.
3. Contractor shall recycle materials per attached specification 01 74 19, Construction Waste Management. Contractor shall inform VA of all quantities of materials recycled in this manner per this specification.
4. Contractor shall submit demolition plan and site staging plan for VA approval prior to beginning work. Demolition may be performed by method of contractor's choice. Hospital is operational 24/7 and contractor shall be mindful of noise and dust control measures and their impact on the hospital in their planning and during demolition.
5. Area of demolition is a very active area of the campus and includes a loading dock & oxygen storage tanks whose free-flow of traffic must be maintained and operations cannot be hindered at any time. Contractor’s staging plan shall be mindful of these areas and of all hospital functions. Contractor to install temporary fencing to protect the outside flow of traffic and keep debris within the limits of disturbance for this work.
6. Contractor shall cut, cap, and remove abandoned site utilities, including water, sewer, natural gas, and electric back to the main line of their respective utility, without disrupting any utility services to adjacent buildings.
7. Contractor to maintain integrity / mitigate potential risk of collapse of low-voltage utility bank between Buildings 6 & 23 throughout the duration of this project - reference existing site utility plans for location of concern.
8. All utility shutdowns shall be coordinated with COR at least 2 weeks prior. Contractor to coordinate shut-down and deprogramming of the Fire Alarm System with Simplex Grinnell and Biomed during demolition and at the time of hand-off.
FIRE ALARM SYSTEM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
CP101
PAVING PLAN
A
Fi le
P at h
DESIGN DEVELOPMENT
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1055 Clermont St., Denver, CO, 80220
554-17-112
C Project Director
Issue date Chkd By Drwn ByRevisions: Date:
GENERAL NOTES
PAVING DETAILS
Demolish Building C & Replace with Parking
10 NEW
STANDARD
PARKING
SPACES
2" [50mm] MINIMUM OR THICKNESS OF EXISTING GRAVEL.
GRAVEL PATCH3
NTS
1'-0" MAX.
[305mm]
1'-0" MAX.
[305mm]
COMPACTED
BACKFILL
CRUSHED GRAVEL
EXISTING
SURFACE
1. Contractor shall verify all existing conditions and layouts prior to demolition. Notify COR of deviations.
2. Contractor shall use necessary means to protect all items not designated for removal and shall provide appropriate dust control. Coordinate location of dust containment with COR prior to initiating demolition work.
3. Contractor shall recycle materials per attached specification 01 74 19, Construction Waste Management. Contractor shall inform VA of all quantities of materials recycled in this manner per this specification.
4. Direct water to existing storm water system and crown area to prevent creating any low points which could collect water.
5. Drainage/Finished Grading Plan shall be submitted to COR for approval prior to starting work.
NEW SIDEWALK
ASPHALT
SURFACE
4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR
BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL) WHICHEVER
IS GREATER.
PORTLAND CEMENT CONCRETE (PCC) THICKNESS EQUAL TO EXISTING.
FOR TRENCH WIDTHS 4' [1219mm] OR LESS REFER TO VA
STANDARD DETAIL 32 12 16-01 "TYPE 1 UTILITY TRENCH PATCH".
FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC) PAVEMENT
EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY TRENCH PATCH".
2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT
WHICHEVER IS GREATER.
BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR
LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH
PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
TYPE 2 UTILITY TRENCH PATCH2
NTS
TRENCH WIDTHS
GREATER THAN
4'-0" [1219mm]
TRENCH
BACKFILL
SAW CUT EXISTING.
ASPHALT FULL
DEPTH BOTH SIDESTACK COAT (TYP.)
EXISTING ASPHALT
CONCRETE PAVEMENT
PATCH WIDTH IN
ACCORDANCE WITH
AGENCY
REQUIREMENTS
GRANULAR MATERIAL
OR PCC
FOR TRENCH WIDTHS EXCEEDING 4' [1219mm] REFER TO VA
STANDARD DETAIL 32 12 16-02 "TYPE 2 UTILITY TRENCH PATCH".
FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC) PAVEMENT
EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY TRENCH PATCH".
2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT
WHICHEVER IS GREATER.
BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR
LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR
BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL) WHICHEVER
IS GREATER.
REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH
PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
TYPE 1 UTILITY TRENCH PATCH1
NTS
4'-0" MAX.
[1219mm]
1'-0" MAX.
[305mm]
1'-0" MAX.
[305mm]
TRENCH
BACKFILL
ABC 100% MIN.
COMPACTION
ASPHALTIC CONCRETE
SAW CUT EXISTING.
ASPHALT FULL
DEPTH BOTH SIDESTACK COAT (TYP.)
EXISTING
PAVEMENT
PAVING PLAN
NTS
CONCRETE SIDEWALK
NOTES:
1. EXPANSION JOINTS SHALL BE LOCATED WHERE SIDEWALK ABUTS CONCRETE DRIVEWAYS, CURB
OR OTHER ADJACENT STRUCTURES.
2. ONE-HALF INCH BITUMINOUS JOINT FILLER SHALL BE INSTALLED AT EXPANSION JOINT
LOCATIONS AND SHALL EXTEND THE FULL DEPTH OF THE CONCRETE.
3. 1" DEEP CONTRACTION JOINTS SHALL BE PLACED AT INTERVALS OF APPROXIMATELY 15'
[4572mm] OR AT A SPACING THAT MATCHES THE ADJACENT CURB.
4. FORMED CONTRACTION JOINTS SHALL BE FINISHED WITH A TOOL HAVING A 1/4" [6mm] RADIUS.
5. SCORED JOINTS SHALL BE 1/4" [6mm] DEEP AND PLACED AT THE SPACING INDICATED FOR
THE WIDTH OF SIDEWALK OR MATCH SCORED JOINTS OF ADJACENT CURB.
6. CONCRETE SHALL BE FINISHED BY MEANS OF A FLOAT, STEEL TROWELLED AND BROOMED WITH
A FINE BRUSH IN A TRANSVERSE DIRECTION.
7. 1/4" DEEP SCORED JOINTS (TYP) SPACED AT 6' [1829mm] OR EQUAL TO SIDEWALK WIDTH.
1" [25mm]
SCORED OR SAWCUT
CONTRACTION JOINT.
TOP OF CURB
1/4" [6mm]
DEEP SCORED
JOINTS
1/4" [6mm] R.
(TYP.) FORMED
JOINTS ONLY
CLASS "B"
CONCRETE
EXPANSION JOINT WITH
1/4" [6mm] BITUMINOUS
JOINT FILLER
1% MIN.
2% MAX.
1% MIN.
2% MAX.
[1 m m
6" M
IN
VARIES PER PLANS 0' MIN.
10.5' MAX.
[3200mm]
TYPICAL SECTION
EXPANSION AND SCORED JOINT DETAIL
[5 m m
3/
[1 m m
4" (T
YP
60' MAX.
[18288mm]
EXPANSION JOINT TO EXPANSION JOINT
60' MAX.
[18288mm]
EXPANSION JOINT TO EXPANSION JOINT
SEE NOTE 7
(TYP) P
LA
N S
P
ER
P
ER
P
LA
N S
PLAN
2" [51mm] R.
H=DESIGN REVEAL
NOTES:
1. ALL CONCRETE CURBS AND TRANSITIONS, SHALL HAVE
A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI.
2. MAXIMUM SPACING ON SCORED JOINTS SHALL BE 15'
[4572mm].
3. 1/2" [13mm] THICK EXPANSION JOINTS SHALL BE
LOCATED AT TANGENT POINTS IN CURB RETURNS,
TRANSITIONS, AND AT A MAXIMUM OF 60' [1828.8cm]
INTERVALS. EXPANSION MATERIAL SHALL ALSO BE
PLACED BETWEEN CURBS AND ADJACENT STRUCTURES,
SIDEWALKS, DRIVEWAYS AND CURB ACCESS RAMPS.
THE 1/2" [13mm] JOINT FILLER SHALL EXTEND THE
FULL DEPTH OF THE CONCRETE.
4. CONCRETE SHALL BE FINISHED WITH A STEEL TROWEL
FOLLOWED BY BRUSHING WITH A FINE BRUSH ALONG
THE LENGTH OF THE CURB OR CURB AND GUTTER.
5. SINGLE CURB MAY BE CONSTRUCTED BY THE USE OF
FORMS OR MAY BE SLIP FORMED.
6. ALL EXPOSED EDGES AND HAND TOOLED JOINTS SHALL
BE FINISHED WITH A TOOL HAVING A 1/4" [6mm]
RADIUS UNLESS A LARGER RADIUS IS INDICATED BY
THE APPLICABLE STANDARD DETAIL OR PROJECT
PLANS.
7. FOR REVEALS OF 6" [152mm] TO LESS THAN 8" [203mm].
8. FOR REVEALS OF 8" [203mm] TO 10" [254mm].
CONCRETE CURB4
NTS
ROADWAY &
PAVEMENT
WIDTH
CONCRETE VERTICAL CURB
[241mm]
NOTE 7
9 1/2"
[254mm]
NOTE 8
10"
[4 m m
N O
TE
[3 m m
N O
TE
6" [152mm]
"H
1:4 CURB
BATTER
PERIMITER
CURB
| Model |
| GI 001 |
| CD 101 |
| CP 101 |