36C25819B0033 Attach A - Existing Conditions.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25819C0138-000.docx | DOCX document | |
| 36C25819B0033-0002004.pdf | ||
| 36C25819B0033-0002005.pdf | ||
| 36C25819B0033-0002003.pdf | ||
| 36C25819B0033-0002002.pdf | ||
| 36C25819B0033-0002000.docx | DOCX document | |
| 36C25819B0033-0002001.pdf | ||
| 36C25819B0033-0001000.docx | DOCX document | |
| 36C25819B0033-005.pdf | ||
| 36C25819B0033-004.pdf | ||
| 36C25819B0033-012.pdf | ||
| 36C25819B0033-015.pdf | ||
| 36C25819B0033-010.pdf | ||
| 36C25819B0033-003.pdf | ||
| 36C25819B0033-009.pdf | ||
| 36C25819B0033-018.pdf | ||
| 36C25819B0033-001.docx | DOCX document | |
| 36C25819B0033-016.pdf | ||
| 36C25819B0033-006.pdf | ||
| 36C25819B0033-013.pdf | ||
| 36C25819B0033-007.pdf | ||
| 36C25819B0033-014.pdf | ||
| 36C25819B0033-011.pdf | ||
| 36C25819B0033-017.pdf | ||
| 36C25819B0033-019.docx | DOCX document | |
| 36C25819B0033-008.pdf | ||
| 36C25819B0033-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
664-19-320 OR Flooring & Wall Repairs ATTACHMENT A – EXISTING CONDITIONS
VA MEDICAL CENTER
SAN DIEGO
PROJECT:
664-19-320
OR Flooring & Wall Repairs
A. EXISTING CONDITIONS
There are currently seven (7) Operating Rooms (OR) at the VA San Diego Medical Center. Over the years, the flooring system has been replaced with different type of materials. OR-1 flooring system has been recently upgraded to epoxy type of flooring. OR-2 thru OR-7 have sheet vinyl flooring and are part of the scope for this project to be upgraded. The estimated measurements shown in Table 1 are for reference only. Actual area and perimeter for each room will need to be field verified.
Table 1: APPROXIMATE MEASUREMENTS
OR #
Room
Perimeter (ft) Base Cove height (in)
Room Area (sf)
Ceiling Ht
2 (RM 5066) 80 6 400 9
3 (RM 5065) 97 6 575 9
4 (RM 5052) 99 6 597 9
5 (RM 5051) 80 6 400 9
6 (RM 5050) 80 6 400 9
7 (RM 5035) 153 8 681 9
7 Scrub
(RM 5036) 51 6 25 9
Total 640 3078
Based on a previous Comprehensive Hazardous Materials Survey for VA San Diego dated
January 2015, asbestos-containing material (ACM) and lead based paint were determined to be present in some of the areas of the facility. Green and white ceramic walls were determined to have high level of lead-based paint. Proper regulations must be followed and implemented during construction to remove and to handle hazardous materials from the work area.
Table 2: EXISTING MATERIALS
B. PHOTO DOCUMENTATIONS (FOR REFERENCE ONLY)
1. OR-2
EXISTING MATERIALS
OR # FLOOR WALL Lead
2 (RM 5066) SVT blue and green ceramic tiles yes
3 (RM 5065) SVT green and white ceramic tiles yes
4 (RM 5052) SVT green and white ceramic tiles yes
5 (RM 5051) SVT blue, green, and white ceramic tiles yes
6 (RM 5050) SVT blue, green, and white ceramic tiles yes
7 (RM 5035) SVT Drywall (non-lead) no
7 Scrub
(RM 5036)
SVT blue, green, and white ceramic tiles yes
OR-2.1 WEST DOOR
OR-2.2
OR-2.3 EAST DOOR
2. OR-3
OR-3.1 WEST DOOR
OR 3.2 WEST DOOR
OR-3.3
OR-3.4 EAST DOOR
3. OR-4
OR-4.1 WEST DOOR
OR-4.2
OR-4.3 EAST DOOR
OR-4.4
4. OR-5
OR-5.1 WEST DOOR
OR-5.2
OR-5.3
5. OR-6
OR-6.1 EAST DOOR
OR-6.2
OR-6.3
OR-6.4 WEST DOOR
6. OR-7
OR-7.1 SOUTH DOOR
OR-7.2 WEST DOOR
OR-7.3
OR-7.4 LOOKING AT NORTH WALL
OR-7.5 SCRUB ROOM DOOR
OR-7.6 SCRUB ROOM
OR-7.7 WEST DOOR
7. CORRIDORS
C-5044.1 LOOKING NORTHWARD
C-5044.2 LOOKING WESTWARD
C-5044.3 LOOKING EASTWARD
C-5049.1 LOOKING SOUTHWARD
C-5073.1 LOOKING SOUTHWARD
C-5073.2 LOOKING AT OR-6 AND OR-5 DOORS
C-5073.3 LOOKING SOUTHWARD
C-5068.1 LOOKING NORTHWARD
C-5063.1 LOOKING WESTWARD