About this file

36C25819B0033 0002 Attach E - Comprehensive Hazardous Materials Survey.pdf

View the file

Other files

File Type Posted
36C25819C0138-000.docx DOCX document
36C25819B0033-0002004.pdf PDF
36C25819B0033-0002005.pdf PDF
36C25819B0033-0002003.pdf PDF
36C25819B0033-0002002.pdf PDF
36C25819B0033-0002000.docx DOCX document
36C25819B0033-0001000.docx DOCX document
36C25819B0033-005.pdf PDF
36C25819B0033-004.pdf PDF
36C25819B0033-012.pdf PDF
36C25819B0033-015.pdf PDF
36C25819B0033-010.pdf PDF
36C25819B0033-003.pdf PDF
36C25819B0033-009.pdf PDF
36C25819B0033-002.pdf PDF
36C25819B0033-018.pdf PDF
36C25819B0033-001.docx DOCX document
36C25819B0033-016.pdf PDF
36C25819B0033-006.pdf PDF
36C25819B0033-013.pdf PDF
36C25819B0033-007.pdf PDF
36C25819B0033-014.pdf PDF
36C25819B0033-011.pdf PDF
36C25819B0033-017.pdf PDF
36C25819B0033-019.docx DOCX document
36C25819B0033-008.pdf PDF
36C25819B0033-000.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment E

Comprehensive Hazardous Materials Survey

ASBESTOS AND LEAD INSPECTION REPORT

VA Hospital – San Diego Page 44 of 149 Asbestos AHERA Inspection and Lead-Based Paint Inspection Report ENCORP Project Number P14320.V11

Building 1: 5th Floor Interstitial:

SUMMARY OF SUSPECT MATERIALS TESTED

Building Material Component Location Of Material Estimated Quantity

Material Category Sample Number % and type of

Asbestos Friability Condition Hazard Ranking Recommendations

Fireproofing Overspray 5th Floor Interstitial 55,000 sq ft Surf 407626- 16 407627- 17 407628- 18

3% Chrysotile Friable G 6

Continue O& M procedures

Follow guidelines under Note 2 below

Fireproofing Beam 5th Floor Interstitial 90,00 sq ft Surf 407629- 19 407630- 20 407631- 21

3% Chrysotile Friable G 6

Continue O& M procedures

Follow guidelines under Note 2 below

Fireproofing Column 5th Floor Interstitial 30,000 sq ft Surf 407611- 1 407612- 2 407613- 3

8% Chrysotile Friable G 6

Continue O& M procedures

Follow guidelines under Note 2 below

Thermal System Insulation Elbows 5th Floor Interstitial 1,000 sq ft TSI

407614- 4 407615- 5 407616- 6

3% Chrysotile Friable G 9 Continue O& M procedures

Fiberglass Pipe Wrap 5th Floor Interstitial - TSI 407617- 7 407618- 8 407619- 9

ND Friable G N/A Samples indicate materials is non-asbestos

Brown Duct Seam Caulking 5th Floor Interstitial 2,500 ln ft Misc 407620- 10 407621- 11 407622- 12

5% Chrysotile Non G 11 Continue O& M procedures

Plaster 5th Floor Interstitial - Surf 407623- 13 407624- 14 407625- 15

ND Non G N/A Samples indicate materials is non-asbestos

Cloth Pipe Wrap 5th Floor Interstitial 2,500 ln ft TSI 407632- 22 407633- 23 407634- 24

80% Chrysotile Friable G 9 Continue O& M procedures

Green Duct Seam Caulking 5th Floor Interstitial - Misc 407635- 25 407636- 26 407637- 27

ND Non G N/A Samples indicate materials is non-asbestos Note: Conditions of materials are identified as follows: Good (G), Damaged (D), or Significantly Damaged (SD). The quantities listed are for budgetary purposes only.

Contractors completing proposals for the removal of asbestos containing materials are responsible for verifying the location, quantity, degree of difficulty and necessity for removing the identified materials.

Note 2: All activities involving work above T-Bar ceilings, air plenums etc., including removal and or changing of panels and ceiling, where ACM fireproofing is found should be performed by (at a minimum) 16-hour AHERA Operations and Maintenance Trained individuals (or Licensed Abatement Contractor) under proper PPE and containment. Until exposure assessments are determined, all asbestos disturbance work should be assumed to be above the OSHA Permissible Exposure Limits.