VICINITY MAP
PROJECT LOCATION: BASEMENT OF BUILDING 126
N
BLDG. 1
BLDG. 4
BLDG. 5
BLDG. 6
BLDG. 8
BLDG. 160
FACILITY MAP
DEPARTMENT OF VETERANS AFFAIRS
5901- EAST SEVENTH STREET
LONG BEACH, CALIFORNIA, 90822
PROJECT DIRECTORY
ARCHITECT
SWA ARCHITECTS
48 EAST HOLLY STREET,
PASADENA, CA 91103
CONTACT: ALLEN CHENG,
WILLIAM BRACE
TEL. 626-793-9805
FAX. 626-793-9807
STRUCTURAL ENGINEER
IMEG CORP
300 N. LAKE AVE., 14TH FL
PASADENA, CA 91101
CONTACT: BORIS ARUTYUNYAN
TEL. 626-463-2755
FAX. 626-463-2801
MECHANICAL ENGINEER
IMEG CORP
300 N. LAKE AVE., 14TH FL
PASADENA, CA 91101
CONTACT: HIMANSU SHAH, PE,
MIKE TRAN
TEL. 626-463-2865
ELECTRICAL ENGINEER
IMEG CORP
300 N. LAKE AVE., 14TH FL
PASADENA, CA 91101
CONTACT: HIMANSU SHAH, PE,
HENRY DIEP
TEL. 626-463-2865
MECHANICAL ENGINEER
IMEG CORP
300 N. LAKE AVE., 14TH FL
PASADENA, CA 91101
CONTACT: HIMANSU SHAH, PE,
KAY MAGALANES
TEL. 626-463-2865
FIRE PROTECTION ENGINEERS
JENSEN HUGHES
2099 S. STATE COLLEGE BLVD.,
SUITE 540
ANAHEIM, CA 92806
CONTACT: JULIAN RAMON,
JOHNNY KANG
TEL. 714-450-1700
FOOD SERVICE
WC&P, INC.
8055 EAST TUFFS AVE., SUITE 1320
DENVER, CO 80237
CONTACT: STEVE YOUNG, MARCIN
ZMIEJKO
TEL. 303-649-1600
FAX. 303-649-1660
INDEX OF DRAWINGS
SCOPE OF WORK
THE LOCATION OF THE EXISTING KITCHEN IS IN THE BASEMENT OF BUILDING
126 AND HAS AN AREA OF APPROXIMATELY 17,000 SQ. FT. THE EXISTING SYSTEMS
AND KITCHEN EQUIPMENT ARE IN THE POOR CONDITION, MANY HAVE BEEN
REMOVED. CURRENTLY, THE KITCHEN IS USED AS A WARM UP PLACE FOR FOOD
BOUGHT FROM VA WEST LOS ANGELES. THIS PROJECT WILL REACTIVATE THE
KITCHEN SO THAT IT IS FULLY FUNCTIONAL FOR THE NEXT APPROXIMATELY 25
YEARS.
THE PROJECT WILL BE PERFORMED IN PHASES TO ALLOW CONTINUOUS
OPERATION OF THE EXISTING ROOM B126 KITCHEN DURING CONSTRUCTION
INDEX OF DRAWINGS
APPLICABLE CODES
PROJECT DATA
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
SWA Architects
SWA 20170024
TIBOR RUBIN VA MEDICAL CENTER
B126 RENOVATE HOSPITAL ROOM SERVICE KITCHEN
DEFERRED SUBMITTALS
PLUMBING
MECHANICAL
1. PROVIDE FIRE PROTECTION FOR BUILDING UNDER CONSTRUCTION PER
REQUIREMENTS OF LOCAL GOVERNING AGENCIES.
2. PROVIDE AND INSTALL MATERIALS FOR FIRE PROTECTION OF THE
STRUCTURAL ASSEMBLIES OF THIS BUILDING TYPE, AS REQUIRED BY THE
BUILDING CODE.
3. WHERE REQUIRED BY CODE, CORRIDORS, AND ELECTRICAL ROOMS SHALL BE
OF ONE-HOUR CONSTRUCT ON THROUGHOUT UNLESS NOTED OTHERWISE.
4. PROVIDE AND INSTALL FIRE DAMPERS WHERE AIR DUCTS PENETRATE
FIRE-RATED WALLS OR CEILING WHERE REQUIRED BY CODE.
5. WHERE NONCOMBUSTIBLE CONDUIT, PIPES, OR VENTS PENETRATE A
FIRE-RATED ASSEMBLY PROVIDE AND INSTALL APPROVED FIRE-RATED
SEALANT OF MINERAL WOOL FIBER TO DRAFTSTOP AND MAINTAIN THE FIRE
SAFE INTEGRITY OF THE ASSEMBLY.
6. RETURN AIR PLENUMS BETWEEN FLOOR OR ROOF ASSEMBLIES AND
SUSPENDED CEILINGS BELOW SHALL MEET THE FOLLOWING REQUIREMENTS.
A. SHALL HAVE NO EXPOSED MATERIALS WITHIN THE PLENUM WITH A FLAME
SPREAD RATING MORE THAN 25 OR A SMOKE DEVELOPED RATING MORE
THAN 50.
B. ALL WIRING IN PLENUMS SHALL BE IN NON-COMBUSTIBLE CONDUIT.
C. ALL EXPOSED COMBUSTIBLE FRAMING MEMBERS AND FINISH SURFACES
WITHIN RETURN AIR PLENUMS SHALL BE COVERED WITH A MINIMUM OF
ONE LAYER 1/2" TYPE 'X' GYPSUM BOARD SECURELY NAILED OR
OTHERWISE FASTENED PER APPLICABLE CODE. PROVIDE AND INSTALL ALL
FURRING AND BLOCKING AND TAPE JOINTS AS REQUIRED.
7. DOORS OPENING INTO ONE-HOUR FIRE-RESISTIVE CORRIDORS SHALL BE
PROTECTED WITH SMOKE AND DRAFTSTOP FIRE ASSEMBLIES HAVING A
MINIMUM 20-MINUTE RATING WITH SELF-CLOSERS.
8. INTERIOR WALL AND CEILING FINISHES SHALL BE OF THE FOLLOWING FLAME
SPREAD CLASSIFICATION:
0-25 CLASS I TUNNEL TEST
25-27 CLASS II TUNNEL TEST
76-200 CLASS III TUNNEL TEST
MAXIMUM FLAME SPREAD CLASSIFICATION:
UNSPRINKLERED SPRINKLERED
ENCLOSED STAIRWAY CLASS I CLASS I
EXITWAYS CLASS II CLASS II
ROOMS/OTHER AREAS CLASS III CLASS II
9. WHERE REQUIRED OR SPECIFIED, PROVIDE AND INSTALL AN AUTOMATIC FIRE
SPRINKLER SYSTEM AND ALARM. SPRINKLER SYSTEM PLANS SHALL BE
SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVAL OF SYSTEM LAYOUT
AND HEADS PRIOR TO SUBMITTAL TO VA FOR REVIEW AND APPROVAL PRIOR
TO INSTALLATION. ANY CHANGES TO ACCOMMODATE FIELD CONDITIONS SHALL
BE RESUBMITTED AT THE CONTRACTORS EXPENSE WITH NO ADDITIONAL
CHARGE TO GOVERNMENT. WHERE ENUNCIATOR PANELS, ALARMS, ETC. ARE
REQUIRED IN AN EXPOSED LOCATION, CONTRACTOR SHALL SUBMIT PROPOSED
LOCATIONS & CABINET/COVER PLATE FINISHES TO ARCHITECT FOR APPROVAL
PRIOR TO INSTALLATION.
1. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL
LABOR, MATERIALS AND SERVICES NECESSARY FOR COMPLETION OF ALL WORK
SHOWN, PRESCRIBED, OR REASONABLY IMPLIED BUT NOT LIMITED TO THAT
EXPLICITLY INDICATED IN THE CONTRACT DOCUMENTS.
A. PLANS HAVE BEEN PREPARED FROM VISUAL AND MEASUREMENTS OF A
ACCESSIBLE AREA. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITION.
THE A-E CAN NOT GUARANTEE THE EXACT CONDITION OF ALL EXISTING
WORK.
2. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, ORDINANCES,
AND REGULATIONS AS ADOPTED BY LOCAL VA.
A. CONTRACTOR TO OBTAIN PERMIT FROM LONG BEACH FIRE DEPARTMENT AS
DIRECTED BY VA.
3. DIMENSIONS ON DRAWINGS ARE SHOWN TO CENTER LINE OF COLUMNS AND TO
FACE OF CONCRETE OR FACE OF STUD AT WALLS AND PARTITIONS UNLESS
NOTED OTHERWISE.
4. DO NOT SCALE DRAWINGS.
5. LANDSCAPE, CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE
PROTECTION, FIRE ALARM, AND EQUIPMENT DRAWINGS ARE SUPPLEMENTAL TO
THE ARCHITECTURAL DRAWINGS. THE CONTRACTOR SHALL REVIEW ALL PLANS
AND DRAWINGS. IN THE EVENT OF CONFLICTING STATEMENTS, INSUFFICIENT
INFORMATION, OR ERRORS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY
GOVERNMENT AND OBTAIN CLARIFICATION BEFORE ANY WORK IS BEGUN. WORK
INSTALLED WHERE CONFLICTING CONDITIONS EXIST, WITHOUT APPROVAL BY
GOVERNMENT, SHALL BE CORRECTED AT CONTRACTOR'S EXPENSE.
A. IN CASE OF CONFLICTS, THE MORE STRINGENT REQUIREMENT GOVERNS.
6. DIMENSIONS, DETAILS, NOTES, AND/OR SYMBOLS THAT APPLY TO ONE UNIT,
APPLY TO ALL UNITS IN LIKE SITUATIONS UNLESS NOTED OTHERWISE.
7. DETAILS NOTED AS 'TYPICAL' SHALL APPLY IN ALL LIKE CONDITIONS UNLESS
SPECIFICALLY SHOWN OR NOTED OTHERWISE. WHERE NO SPECIFIC DETAIL IS
SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO
THAT INDICATED FOR LIKE CASES OF CONSTRUCTION IN THIS PROJECT.
8. WHENEVER AN ARTICLE, DEVICE, OR PIECE OF EQUIPMENT IS SHOWN,
INDICATED, OR REFERRED TO ON THE DRAWINGS OR IN THESE NOTES IN THE
SINGULAR NUMBER, SUCH REFERENCES APPLY TO AS MANY SUCH ARTICLES AS
ARE REQUIRED TO COMPLETE THE INSTALLATION.
9. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY ALL
DIMENSIONS AND CONDITIONS ON THE JOB SITE PRIOR TO BEGINNING
CONSTRUCTION AND SHALL REPORT ANY DISCREPANCIES OR UNIDENTIFIED
CONDITIONS TO THE CONTRACTING OFFICER FOR RESOLUTION BEFORE ANY
WORK IS BEGUN.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES
AND PROCEDURES EMPLOYED IN THE PERFORMANCE OF WORK IN, ON, OR
ABOUT THE JOB SITE; THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL
WORK PERFORMED BY SUBCONTRACTORS. FOR EXAMPLE, ACCESS TO THE AREA
FOR CONSTRUCTION AND EQUIPMENT DELIVERY.
11. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK ON, OR
RELATED TO THIS PROJECT SHALL CONDUCT THEIR OPERATIONS SO THAT
ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC IS
PROTECTED, AND SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND
HEALTH ACT" OF THE U.S. DEPARTMENT OF LABOR AND WITH ANY AND ALL
OTHER APPLICABLE STATE AND/OR LOCAL SAFETY REGULATIONS. THE
CONTRACTOR AGREES TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE SAFETY CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS. AND THAT THE CONTRACTOR SHALL
DEFEND, INDEMNIFY AND HOLD HARMLESS THE GOVERNMENT AND ARCHITECT
FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
PERFORMANCE OF WORK ON THIS PROJECT.
12. UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS, NO STRUCTURAL
MEMBER SHALL BE CUT, NOTCHED, BORED, OR OTHERWISE MODIFIED WITHOUT
PERMISSION OF THE GOVERNMENT. SHORE/PROTECT REMAINING (E) STRUCTURE
UNTIL ALL (N) WORK IS COMPLETED.
13. WHETHER OR NOT DETAILED ON DRAWINGS, THE CONTRACTOR SHALL PROVIDE
AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES, AND SUPPORTING
BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK AND OF ALL
WALL-MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL, OR MISCELLANEOUS
EQUIPMENT, INCLUDING PLYWOOD BACKBOARDS FOR TELEPHONE AND
ELECTRICAL EQUIPMENT ROOMS.
14. NEITHER THE ARCHITECT'S/GOVERNMENT'S REVIEW NOR APPROVAL OF SHOP
DRAWINGS SHALL RELIEVE THE GENERAL CONTRACTOR (G.C.) FROM
RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS UNLESS
G.C. HAS CALLED THE ARCHITECT'S/GOVERNMENT'S ATTENTION (IN WRITING) TO
SUCH DEVIATIONS AT THE TIME OF SUBMISSION, NOR SHALL IT RELIEVE G.C. OF
RESPONSIBILITY FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS.
15. THE CONTRACTOR IS RESPONSIBLE TO VERIFY LOCATION OF ALL SITE UTILITIES
AND TO COORDINATE AND AVOID CONFLICT IN THE LOCATIONS OF NEW
UNDERGROUND AND SITE UTILITIES. THE CONTRACTOR SHALL INCLUDE ALL
NECESSARY FEES, METERS, AND CONNECTIONS IN HIS BID, AND SHALL NOT
START CONSTRUCTION ACTIVITIES UNTIL ALL UTILITIES HAVE BEEN PRECISELY
IDENTIFIED IN BOTH LOCATION AND DEPTH. IF REQUIRED, CONTRACTOR TO USE
PRIVATE COMPANY FOR GROUND PENETRATING RADAR (GPR) AND/OR POT
HOLING TO DETERMINE LOCATION OF (E) UNDERGROUND UTILITIES.
16. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE GOVERNMENT SHOULD
UNIDENTIFIED FIELD CONDITIONS BE DISCOVERED.
17. ON A SET OF DRAWINGS, THE CONTRACTOR SHALL KEEP AN UP-TO-DATE
RECORD OF "AS BUILT" CONDITIONS OF THE WORK. UPON COMPLETION OF THE
WORK, THAT SET SHALL BE RETURNED TO THE GOVERNMENT COMPLETELY AND
NEATLY POSTED SHOWING ALL ADDITIONS, DELETIONS, CORRECTIONS, AND
REVISIONS IN THE ACTUAL CONSTRUCTION OF THE PROJECT. RECORD
DRAWINGS SHALL BE SIGNED BY SUBCONTRACTORS REPRESENTING ALL MAJOR
TRADES FOR THE PROJECT AS WELL AS THE GENERAL CONTRACTOR.
KEYNOTE
NORTH ARROW
IDENTIFIER
PHOTO IDENTIFIER
N
XX
X
DOOR NUMBER
WINDOW NUMBER
ROOM NUMBER
INTERIOR FINISH
ROOM NAME
DETAIL PLAN
INDICATOR
DETAIL NUMBER
GRID LINES
EQUIPMENT NUMBER
WALL TYPE
XX
XX
X
XX
X
XX
X
ELEVATION OR
SECTION
INDICATOR
SHEET NUMBER
ON WHICH SECT. IS
DRAWN
SECTION
IDENTIFIER
XX
X
SHEET NUMBER
ON WHICH SECT. IS
DRAWN
DETAIL INDICATOR
XXXX
X
SHEET NUMBER
ON WHICH SECT. IS
DRAWN
DETAIL NUMBER
REF. NO. OF SHEET
ON WHICH DET. IS
TAKEN
X
X
X
X
ELEVATION
INDICATOR,
INTERIOR
MULTIPLE VIEW
ELEVATION
INDICATOR,
EXTERIOR
XX
XX
XXX
XXX
AREA=SQ.FT
ACCESSIBILITY
DOORS
PARTITIONS
1. ALL STUDS AT NON-BEARING INTERIOR PARTITIONS SHALL BE STEEL 4" WIDE X 18
GAUGE (MIN.) UNLESS NOTED OTHERWISE.
2. PROVIDE AND INSTALL HEAVIER 16 GAUGE STUDS, STIFFENERS, BRACING,
BACK-UP PLATES, ETC., AS REQUIRED AT STUD WALLS FOR SUPPORT OF TOILET
ROOM FIXTURES OR OTHER EQUIPMENT.
3. SEE WALL LEGENDS OR CALLOUTS ON PLANS FOR GYPSUM BOARD
THICKNESS AND FIRE RATING, AND FOR INSULATION AS REQUIRED.
1. DOORS AND DOORWAYS: THE FLOOR ADJACENT TO A DOORWAY SHALL BE
LEVEL FOR A DISTANCE OF FIVE FEET FROM THE DOOR IN THE DIRECTION OF
DOOR SWING AND SHALL BE NOT LESS THAN 5 FT. WIDE.
2. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED WHERE REQUIRED BY, AND IN
ACCORDANCE WITH, APPLICABLE LAWS.
3. ALL REQUIRED EXITS SHALL HAVE EXIT SIGNS AND ALL BLIND CORRIDOR TURNS
SHALL HAVE DIRECTIONAL EXIT SIGNS WITH A PRINCIPAL STROKE NOT LESS
THAN 3/4" WIDE AND 6" HIGH.
4. WALLS AND CLG. OF CORRIDORS SERVING MORE THAN 30 OCCUPANCY SHALL
BE ONE-HR. MIN. FIRE-RATED CONST. CORRIDOR WALLS AND CEILING NEEDED
NOT BE OF FIRE-RESISTIVE CONST. WITHIN OFFICE SPACES HAVING AN
OCCUPANT LOAD OF 100 OR LESS WHEN THE ENTIRE STORY IN WHICH THE
SPACE IS LOCATED IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM
THROUGHOUT AND SMOKE DETECTORS ARE INSTALLED WITHIN THE CORRIDOR
IN ACCORDANCE WITH THEIR LISTING.
1. DOORS AND HARDWARE:
A. OPENING TO BE MINIMUM OF 36" WIDE X 80" HIGH WHEN DOOR IS AT RIGHT
ANGLE TO CLOSED POSITION, UNLESS NOTED OTHERWISE.
B. BOTTOM 10" OF DOOR TO HAVE SMOOTH UNINTERRUPTED SURFACE FOR
OPENING BY WHEELCHAIR FOOT REST. PROVIDE KICK PLATES ON ALL DOORS.
C. CENTER OF HARDWARE TO BE 34 TO 44 INCHES ABOVE FLOOR. LATCHING
AND LOCKING DOORS TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER OR
PUSH-PULL TYPE HARDWARE.
D. MAXIMUM EFFORT TO OPERATE DOOR SHALL NOT EXCEED 15 POUNDS FOR
EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS WITH A PULL OR
PUSH EFFORT BEING APPLIED AT RIGHT ANGLE TO HINGED DOORS AND AT
THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING
DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE
ABOVE STANDARDS. WHEN FIRE RATED DOORS ARE REQUIRED, THE
MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO
EXCEED 15 POUNDS WITH CLOSER.
E. THRESHOLD SHALL BE 1/2" HIGH MAXIMUM WITH 1/4" HIGH MAX. VERTICAL
EDGE BELOW A BEVELED EDGE AT 1:2 SLOPE FOR A HEIGHT OF 1/4" MAXIMUM.
DEMOLITION NOTES
1. SEE DEMOLITION PLANS FOR ADDITIONAL NOTES AND INFORMATION.
2. THE CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE FULL EXTENT OF THE
DEMOLITION. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND AREAS TO
BE DEMOLISHED PRIOR TO THE COMMENCEMENT OF WORK. BRING TO THE
ATTENTION OF THE OWNER AND ARCHITECT ANY DISCREPANCIES PRIOR TO AND
DURING CONSTRUCTION.
3. MATERIALS, EQUIPMENT, OR CONSTRUCTION NOT NOTED IN THE CONSTRUCTION
DOCUMENTS ARE NOT PART OF THE NEW WORK. IF SUCH IS DISCOVERED DURING
THE COURSE OF THE WORK, CONTRACTOR SHALL REPORT TO THE ARCHITECT
FOR FURTHER INSTRUCTION.
4. COORDINATE ALL DEMOLITION WORK WITH RENOVATION WORK. COORDINATE
ARCHITECTURAL, CIVIL, STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING AND
FIRE PROTECTION WORK WITH EACH OTHER FOR LOCATIONS, EXTENT OF WORK
AND SIZES.
5. PROTECT ADJACENT SPACES FROM DAMAGE DURING THE PROGRESS OF THE
WORK. PROVIDE TEMPORARY SAFETY BARRIERS REQUIRED BY CODE TO ENSURE
PUBLIC SAFETY TO ALLOW BUILDING OCCUPANCY. SEE WORK SEQUENCE PLANS
FOR MORE INFORMATION.
6. PROVIDE TEMPORARY DUST PROOF PARTITIONS WHERE NECESSARY TO PREVENT
INFILTRATION OF DUST INTO OCCUPIED AREAS. PROVIDE TEMPORARY WEATHER
PROTECTION AS NECESSARY TO PREVENT DAMAGE TO EXISTING FACILITIES AND
TO PREVENT DISCOMFORT TO PERSONS IN OCCUPIED AREAS. SEE WORK
SEQUENCE PLANS FOR MORE INFORMATION.
7. NOTIFY CONTRACTING OFFICER ONE WEEK IN ADVANCE PRIOR TO CORE DRILLING,
JACK HAMMERING, CONCRETE SAWING OR OTHER NOISY WORK.
8. VERIFY DISPOSAL AND SALVAGE WITH CONTRACTING OFFICER. GOVERNMENT
RESERVES THE RIGHT TO SALVAGE ANY DEMOLITION ITEM. REMOVE, PROTECT
AND TURN OVER SUCH ITEMS TO THE GOVERNMENT.
9. ALL SALVAGEABLE ITEMS SHALL BE PROPERTY OF THE OWNER AND SHALL BE
REUSED OR STORED WHERE DESIGNATED BY THE OWNER.
10. RECEIVE CONTRACTING OFFICER APPROVAL OF DEBRIS HAULING ROUTE AND
DUMPSTER LOCATION PRIOR TO START OF WORK.
11. ALL DEBRIS SHALL BE PROMPTLY REMOVED FROM THE SITE.
12. REMOVAL OF ALL DEBRIS SHALL BE DONE CAREFULLY SO AS NOT TO DAMAGE THE
EXISTING STRUCTURE, WORK AND/OR FINISHES. IN THE EVENT ANY DAMAGES
OCCUR, THEY SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE OWNER.
13. IN ADDITION TO DEMOLITION SHOWN: CUT, MOVE OR REMOVE ITEMS AS
NECESSARY TO PROVIDE ACCESS AND ALLOW REPAIR OR NEW WORK TO
PROCEED. INCLUDE SUCH ITEMS AS:
A. REPAIR OR REMOVAL OF HAZARDOUS OR UNSANITARY CONDITIONS:
B. REMOVAL OF ABANDONED ITEMS AND ITEMS SERVING NO USEFUL PURPOSE
SUCH AS: ALL PIPING, DEAD-LEGS, CONDUIT, WIRING, DUCTWORK, DIFFUSERS
AND ANY ASSOCIATED HARDWARE/ FIXTURES ETC.
C. REMOVAL OF UNSUITABLE OR EXTRANEOUS MATERIALS NOT MARKED FOR
SALVAGE. SUCH ITEMS MAY INCLUDE ABANDONED FURNISHINGS, EQUIPMENT
AND DEBRIS SUCH AS ROTTED WOOD, RUSTED METALS AND DETERIORATED
CONCRETE.
D. CLEANING OF SURFACES OR REMOVAL OF SURFACE FINISHES AS NEEDED TO
INSTALL NEW WORK AND FINISHES.
FIRE PROTECTION (FULLY SPRINKLERED BUILDING):
GENERAL NOTES
ABBREVIATIONS
AB AGGREGATE BASE
AC ASPHALT CONCRETE
ACT ACOUSTICAL CEILING
TILE
AD AREA DRAIN
AG ANCHOR GUY
APPROX APPROXIMATE
BFP BACKFLOW PREVENTOR
BLDG BUILDING
BW BACK OF WALK
B.1. BOTTOM OF
CB CATCH BASIN
CD CURB DRAIN
CLR. CLEAR
CONC CONCRETE
DEPT. DEPARTMENT
DET DETAIL
DIA DIAMETER
DWG DRAWING
(E) EXISTING
EC EDGE OF CONCRETE
ES EDGE OF STAIRS
EG EDGE OF GUTTER
ELEC ELECTRICAL
EPDMETHYLENE PROPYLENE
DIENE TERPOLYMER
EW EDGE OF WALK
FDC FIRE DEPT.
CONNECTION
FIN FINISH
FL FLOW LINE
FS FINISH SURFACE
FT FEET
FW FRONT OF WALK
GB GRADE BREAK
GC GENERAL CONTRACTOR
GR GAS RISER
GM GAS METER
GND GROUND
GYP. BD. GYPSUM BOARD
IN INCHES
INFO INFORMATION
INV INVERT
IPB IRRIGATION PULL BOX
IRR IRRIGATION
MAX MAXIMUM
MECH. MECHANICAL
MGMT. MANAGEMENT
MIN MINIMUM
NGL NATURAL GRADE LEVEL
NTS NOT TO SCALE
(N) NEW
O.C. ON CENTER
PT PRESSURE TREATED
RAD RADIUS
REINF REINFORCED
RF RADIO FREQUENCY
SQ SQUARE
S.O.G. SLAB ON GRADE
STL STEEL
T.O. TOP OF
TC TOP OF CURB
TG TOP OF GRATE
THK THICK
TOF TOP OF FLOOR
TW TOP OF WALL
TYP TYPICAL
U.N.O. UNLESS NOTED
OTHERWISE
U.O.N. UNLESS OTHERWISE
NOTED
VIF VERIFY IN FIELD
SYMBOLS LEGEND
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
SWA Architects
SWA 20170024
0. ALL CONTRACTOR AND SUB-CONTRACTOR PERSONNEL, WHO WILL WORK AT THE VA
CONSTRUCTION SITE SHALL OBTAIN T.B. CLEARANCE CERTIFICATE FROM A PHYSICIAN, AND
SUBMIT IT TO THE CONTRACTING OFFICER REPRESENTATIVE, BEFORE THEY START WORK. THE
COST OF OBTAINING THESE CERTIFICATES WILL BE BORNE BY THE CONTRACTOR.
INFECTION CONTROL NOTES
1. INSTALL AND MAINTAIN CONSTRUCTION CRITICAL BARRIERS AND CEILING PROTECTION.
2. ISOLATE HVAC SYSTEM WITHIN WORK AREAS TO PREVENT CONTAMINATION OF DUCT
SYSTEM.
3. SEAL DOORS OPENING TO ADJACENT AREAS WITH DUCT TAPE.
4. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES.
5. BLOCK OFF AND SEAL HVAC REGISTERS, GRILLS AND ANY OPENINGS IN DUCTWORK TO
REMAIN.
6. MAINTAIN NEGATIVE PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS.
7. NEGATIVE PRESSURE MONITORING DEVICES SHOULD BE VISIBLE FROM OUTSIDE THE
WORKSITE AND READINGS SHOULD BE DOCUMENTED AS LEAST DAILY.
8. MAINTAIN CLEAN WALK OFF MATS AT ENTRANCE AND EXIT OF WORK AREA.
9. COVER CONSTRUCTION WASTE BEFORE TRANSPORT IN COVERED AND SEALED
CONTAINERS.
10. COVER CONSTRUCTION WASTE BEFORE TRANSPORT IN COVERED AND SEALED
CONTAINERS.
11. PROVIDE MONITORING AND CLEARANCE SAMPLES FOR MOLD/ASBESTOS.
12. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM
SO THEY CAN BE VACUUMED USING A HEPA VACUUM CLEANER BEFORE LEAVING WORK
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH TIME
THEY LEAVE WORK SITE.
ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. SHOE COVERS
MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.
LIFE SAFETY DURING CONSTRUCTION NOTES:
C
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
36" 36"
FD
2" FS
FD
2" FS
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
R
D
R
G
GG
C
C
D
G
CWI
CWO
H
C
H
C
H
C
36"
H
C
H
C
H
C
H
C
H
C
H
C
C
C
C
D
D
C
D D
H
C
H
C
H
C
H
C
H
C
H
C
G
C H
C
D D
H
C
H
C
H
C
D D
H
C
H
C
H
C
G
C H
H
C
H
C
H
C
C
C
D
G
C W I
C W O
CC
D
G
C W I
C W O
C
C D
G
H
C
H
C
H
C
H
C
H
C
H
C
G G
G
GG
C
C
D
G
CWI
CWO
G G
DD
C H
CH CH
2" FS
2" FS
2" FS
FD
3" FS
4" FS
2" DIRECT
DRAIN
2" FS
2" FS2" FS
2" FS
2" FS
2" FS
2" FS
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
2" FS
2" FS
2" FS
2" FS
4" FS
FD
2" FS
2" FS
FD
FD
FD
FD
H
C
H
C
H
C
H
C
H
C
H
C
H
C
36" H
C
H
C
H
C
FD
D D
D
A1
A2
B1
B2
A3
B3
C
B
C O
R R
I D
O R
SCALE: 1/8 "=1'-0"
LIFE SAFETY/EGRESS PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
SWA Architects
SWA 20170024
BY
JENSEN HUGHES
SUBMITTAL REVIEWED, NO EXCEPTIONS TAKEN
SUBMITTAL REVIEWED AS NOTED:
RESUBMISSION RESUBMISSION
REQUIRED NOT REQUIRED
APPROVAL NOT RECOMMENDED
THE DRAWINGS HAVE BEEN REVIEWED FOR CONFORMANCE WITH NFPA 101 PER
THE VA FIRE PROTECTION DESIGN MANUAL.
DATE
APRIL 9, 2018 DONALD J. WOOD
TREATMENT
CLINIC
OFFICE
C
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C B
C O
R R
I D
O R
THERAPISTS AREA
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
CORRIDOR
CHF. WARD ADM.
MED. RECORDS STORAGE
AND WORK ROOM STAIR NO.5
M.A.S.
EDUCATION AND
TRAINING CENTER
STAFF
ASSISTANT
SUPERVISORS
WARD
ADMINISTRATION
UP
CHIEF SOCIAL
WORKERS
SERVICE
OFFICE
OFFICE
SEC. TO
CHIEF S.W.S.
SEC. / STEND
S.W.S.
CENTRALIZED
DICTATING EQUIP.
SUPERVISOR
TRANSCRIPTION
UNIT
UNIT
RECORD
REVIEW RM.
CORRESPONDENCE
AND INSURANCE
UP
STAFF
ASSISTANT
OFFICE
CLERK
CLERK
ASST. CHIEF
SOCIAL
WORKER
SERVICE
MEDICAL
TRANSCRIPTION
FD
FD
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
SWA Architects
SWA 20170024
TREATMENT
CLINIC
OFFICE
C
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
THERAPISTS AREA
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
R
D
R
G
GG
C
C
D
G
CWI CWO
H
C
H
C
H
C
36"
H
C
H
C
H
C
H
C
H
C
H
C
C
C
C
D
D
C
D D
H
C
H
C
H
C
H
C
H
C
H
C
G
C H
C
D D
H
C
H
C
H
C
D D
H
C
H
C
H
C
G
C H
H
C
H
C
H
C
C
C
D
G
C W I
C W O
CC
D
G
C W I
C W O
C
C D
G
H
C
H
C
H
C
H
C
H
C
H
C
G G
G
GG
C
C
D
G
CWI
CWO
G G
DD
C H
CH CH
2" FS
2" FS
2" FS
FD
3" FS
4" FS
2" DIRECT
DRAIN
2" FS
2" FS2" FS
2" FS
2" FS
2" FS
2" FS
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
2" FS
2" FS
2" FS
2" FS
4" FS
FD
2" FS
2" FS
FD
FD
FD
FD
H
C
H
C
H
C
H
C
H
C
H
C
H
C
36" H
C
H
C
H
C
FD
CORRIDOR
CHF. WARD ADM.
F.A.C.
M.A.S.
EDUCATION AND
TRAINING CENTER
STAFF
ASSISTANT
SUPERVISORS
WARD
ADMINISTRATION
CHIEF SOCIAL
WORKERS
SERVICE
OFFICE
OFFICE
SEC. TO
CHIEF S.W.S.
SEC. / STEND
S.W.S.
CENTRALIZED
DICTATING EQUIP.
SUPERVISOR
TRANSCRIPTION
UNIT
UNIT
RECORD
REVIEW RM.
CORRESPONDENCE
AND INSURANCE
UP
STAFF
ASSISTANT
OFFICE
CLERK
CLERK
ASST. CHIEF
SOCIAL
WORKER
SERVICE
MEDICAL
TRANSCRIPTION
36" 36"
FD
2" FS
FD
2" FS
PROPOSED OVERALL FLOOR PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103 wkst2 Typewritten text
FOR
REFERENCE
ONLY
joep Typewritten text joep Typewritten text
DRAWING NUMBER
AS-101
DRAWING NUMBER
AS-102
FOR
REFERENCE
ONLY
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
COOKS REFR.
PRE-FAB
OFFICE
ASST. CHIEF
OFFICE
DIETETIC
FA
C
SCALE: 1/8 "=1'-0"
PHASE 1 DEMOLITION PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
TYP.
2A 8
TYP.
2A 8
2A 8
2A 8
2 8
2A 8
SIM.1
SIM.
TYP.
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
2B
2C
4A
4A
4B
4B
SCALE: 1/8 "=1'-0"
PHASE 1 PROPOSED FLOOR PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
REFRIGERATOR
VESTIBULE
F A C
HAC
STORAGE
PAPER
STORAGE
PRE-FAB MEAT
FRZ
PRE-FAB REFR
PRE-FAB VEG REFR
PRE-FAB VEG
FRZ
PRE-FAB
CHILLED
VEG
PRE-FAB MEAT
REFR
REFR
REFR
FREEZER
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
SCALE: 1/8 "=1'-0"
PHASE 2 DEMOLITION PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
R
D
R
G
GG
C
C
D
G
CWI CWO
H
C
H
C
H
C
36"
H
C
H
C
H
C
H
C
H
C
H
C
C
C
C
D
D
C
D D
H
C
H
C
H
C
H
C
H
C
H
C
G
C H
C
D D
H
C
H
C
H
C
D D
H
C
H
C
H
C
G
C H
H
C
H
C
H
C
CC
D
G
C W I
C W O
CC
D
G
C W I
C W O
C
C D
G
H
C
H
C
H
C
H
C
H
C
H
C
G G
G
GG
C
C
D
G
CWI
CWO
G G
DD
C H
CH CH
2" FS
2" FS
2" FS
FD
3" FS
4" FS
2" DIRECT
DRAIN
2" FS
2" FS2" FS
2" FS
2" FS
2" FS
2" FS
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
2" FS
2" FS
2" FS
2" FS
4" FS
FD
2" FS
2" FS
FD
FD
FD
FD
H
C
H
C
H
C
H
C
H
C
H
C
H
C
36" H
C
H
C
H
C
FD
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
TYP.
SIM.
SIM.
TYP.
TYP.
TYP.
TYP.
TYP.
2A 2A
2A
2A
TYP.
2B
2B 33
2A
2C
SIM.
4B
4C
4C
4C
4C
194C
SCALE: 1/8 "=1'-0"
PHASE 2 PROPOSED FLOOR PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
DIETETIC
OFFICE
TEMPORARY
EMPLOYEE
LOUNGE
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
R
D
R
G
GG
C
C
D
G
CWI
CWO
H
C
H
C
H
C
36"
H
C
H
C
H
C
H
C
H
C
H
C
C
C
C
D
D
C
D D
H
C
H
C
H
C
H
C
H
C
H
C
G
C H
C
D D
H
C
H
C
H
C
D D
H
C
H
C
H
C
G
C H
H
C
H
C
H
C
CC
D
G
C W I
C W O
CC
D
G
C W I
C W O
C
C D
G
H
C
H
C
H
C
H
C
H
C
H
C
G G
G
GG
C
C
D
G
CWI CWO
G G
DD
C H
CH CH
2" FS
2" FS
2" FS
FD
3" FS
4" FS
2" DIRECT
DRAIN
2" FS
2" FS2" FS
2" FS
2" FS
2" FS
2" FS
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
2" FS
2" FS
2" FS
2" FS
4" FS
FD
2" FS
2" FS
FD
FD
FD
FD
H
C
H
C
H
C
H
C
H
C
H
C
H
C
36" H
C
H
C
H
C
FD
SCALE: 1/8 "=1'-0"
PHASE 3 DEMOLITION PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
COOKS REFR.
PRE-FAB
OFFICE
ASST. CHIEF
OFFICE
DIETETIC
FA
C
SCALE: 1/8 "=1'-0"
PHASE 1 DEMOLITION PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
TYP.
2A 8
TYP.
2A 8
2A 8
2A 8
2 8
2A 8
SIM.1
SIM.
TYP.
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
2B
2C
4A
4A
4B
4B
SCALE: 1/8 "=1'-0"
PHASE 1 PROPOSED FLOOR PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L C
O V
E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
C B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
REFRIGERATOR
VESTIBULE
F A C
HAC
STORAGE
PAPER
STORAGE
PRE-FAB MEAT
FRZ
PRE-FAB REFR
PRE-FAB VEG REFR
PRE-FAB VEG
FRZ
PRE-FAB
CHILLED
VEG
PRE-FAB MEAT
REFR
REFR
REFR
FREEZER
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
SCALE: 1/8 "=1'-0"
PHASE 2 DEMOLITION PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103
A L
C O
V E
C126-42A
CORRIDOR
C
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
C
B
C O
R R
I D
O R
A.D.L.45
TOILET 48
PERSON. COG.
HYGIENE 46
WHIRLPOOL
EQUIPMENT 40
CLERK'S AREA
R
D
R
G
GG
C
C
D
G
CWI CWO
H
C
H
C
H
C
36"
H
C
H
C
H
C
H
C
H
C
H
C
C
C
C
D
D
C
D D
H
C
H
C
H
C
H
C
H
C
H
C
G
C H
C
D D
H
C
H
C
H
C
D D
H
C
H
C
H
C
G
C H
H
C
H
C
H
C
CC
D
G
C W I
C W O
CC
D
G
C W I
C W O
C
C D
G
H
C
H
C
H
C
H
C
H
C
H
C
G G
G
GG
C
C
D
G
CWI
CWO
G G
DD
C H
CH CH
2" FS
2" FS
2" FS
FD
3" FS
4" FS
2" DIRECT
DRAIN
2" FS
2" FS2" FS
2" FS
2" FS
2" FS
2" FS
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
4" DIRECT
DRAIN
2" FS
2" FS
2" FS
2" FS
4" FS
FD
2" FS
2" FS
FD
FD
FD
FD
H
C
H
C
H
C
H
C
H
C
H
C
H
C
36" H
C
H
C
H
C
FD
2" FS2" FS
2" FS2" FS
2" FS2" FS
FD
FD
TYP.
SIM.
SIM.
TYP.
TYP.
TYP.
TYP.
TYP.
2A 2A
2A
2A
TYP.
2B
2B 33
2A
2C
SIM.
4B
4C
4C
4C
4C
194C
SCALE: 1/8 "=1'-0"
PHASE 2 PROPOSED FLOOR PLAN
tel: 626.793.9805 fax: 626.793.9807
48 east holly street, pasadena, ca 91103