36C25726Q0636 0001-CTX Dental Explansion.pdf

PDF 1 MB Posted

Attached to
CTX Dental Expansion Casework Federal contract opportunity
Solicitation number
36C25726Q0636
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This is a Standard Form 30 (SF 30) Amendment of Solicitation/Modification of Contract issued by the Department of Veterans Affairs, Network Contracting Office 17, located in San Antonio, Texas. The amendment, numbered 0001, is dated June 16, 2026, and modifies solicitation 36C25726Q0636, originally issued on June 11, 2026. The contracting officer is Shawn R. Reinhart.

The sole purpose of this amendment is to provide a Floor Plan for the VA Temple Expansion project that was inadvertently omitted from the initial solicitation. The amendment explicitly states that no other changes have been made to the solicitation. The attached floor plan document, titled "VA Temple Expansion 3-16-26-PRELIMINARY," includes detailed equipment layout specifications and utility requirements (electrical, water, air, vacuum, and data conduit) for what appears to be a dental or medical facility expansion. The preliminary layout, drawn by A-dec SGI on March 16, 2026, provides dimensional specifications and equipment positioning across multiple treatment areas. All terms and conditions of the original solicitation remain unchanged and in full force and effect. Offerors must acknowledge receipt of this amendment prior to the deadline specified in the original solicitation or as amended, or risk rejection of their offer.

View the file

Other files for this federal contract opportunity

Other files attached to CTX Dental Expansion Casework, newest first.
File Type Posted
Attachment 2.jpeg JPEG file
36C25726Q0636-0002.pdf PDF
Attachment 4.jpeg JPEG file
Attachment 5.pdf PDF
Attachment 3.jpeg JPEG file
Attachment 1.jpeg JPEG file
36C25726Q0636.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE 7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO. 1. CONTRACT ID CODE

FACILITY CODE CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30 PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243

(Type or print) (Type or print)

(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code)

(If other than Item 6)

(Specify type of modification and authority)

(such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer)

1 2

0001 06-16-2026

36C671

Department Of Veterans Affairs Network Contracting Office 17

5441 Babcock Road Ste. 302 San Antonio TX 78240

36C671

Department Of Veterans Affairs Network Contracting Office 17

5441 Babcock Road Ste. 302 San Antonio TX 78240

To all Offerors/Bidders

36C25726Q0636

06-11-2026

X

X X

X 1

The purpose of Amendment 0001 is to provide a copy of the Floor Plan that was inadvertently omitted from the initial Solicitation.

No other changes have been made to the soliciation.

Shawn R. Reinhart Contracting Officer

See attached document: VA Temple Expansion 3-16-26-PRELIMINARY.

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)

BAC

K ED

G E O

F BASEPLATE

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H ospital-G rade Q uad Electrical

Box Supplied by C ontractor

(check am perage requirem ents)

ELECTRICAL

09/18 06/13

/1

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)

BAC

K ED

G E O

F BASEPLATE

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H ospital-G rade Q uad Electrical

Box Supplied by C ontractor

(check am perage requirem ents)

ELECTRICAL

09/18 06/13

/1

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)

BAC

K ED

G E O

F BASEPLATE

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H ospital-G rade Q uad Electrical

Box Supplied by C ontractor

(check am perage requirem ents)

ELECTRICAL

09/18 06/13

/1

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)

BAC

K ED

G E O

F BASEPLATE

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H ospital-G rade Q uad Electrical

Box Supplied by C ontractor

(check am perage requirem ents)

ELECTRICAL

09/18 06/13

/1

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

4" - 6" (102 mm - 153 mm)

16" - 18" (406 mm - 457 mm)

16" - 18" (406 mm - 457 mm)

16-7/8" (429 mm)

16-5/8" (422 mm)BA

C K

ED

G

E O

F

BA

SE

PL

AT

E

4" - 6" (102 mm - 153 mm)

11-3/8" (289 mm)

Concentric Mount Pivot Point

01/19

2-1/4" (73 mm)

9" (241 mm) 7" (178 mm)

VACUUM

DRAIN

5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes)

4" (102 mm)

2-7/8" (73 mm)

1-1/4" (33 mm)

1-7/8" (48 mm)

Optional

2" DATA

CONDUIT

(locate as needed)

1-1/2" (38 mm) Nominal Pipe For Gravity Drain (when required)

WATER

AIR

H os pi ta l-G ra de Q ua d

El ec tri ca l Bo x Su pp lie d by

C on tra ct or (c he ck a m pe ra ge re qu ire m en ts

ELECTRICAL

09/18 06/13

08/11

0"154"

3 4"

4" 611

4" 581 2"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

1 4"

3 4"

3 4"

1 4"

1 4"

3 4"

3 4"

1 4"

3 4"

3 4"

1 2"

1 2"

1 2"

3 4"

3 4"

3 4"

1 2"

1 4"

1 2"

1 2"

1 2"

1 2"

4"

1 4"

3 4"

3 4"

1 4"

1 4"

3 4"

3 4"

1 4"

1 4"

3 4"

3 4"

1 4"

1 4"

1 2"

3 4"

1 4"

42" 611 4" 341

4"

1 4"

1 4"

1 4"

104"

1 2"

1 2"

NOTE: NO UPPER

CABINETS ON THIS

WALL

NOTE: NO UPPER

CABINETS ON THIS

WALL

3 4"

2"

3 4"

138"

154"

2"

154"

4"

104"

SHEET NO.

Th is lay ou t is co nc ep tua l in na tur e a nd pr op rie tar y t o A

-d ec eq uip me nt.

It is int en de d t o b e u se d s ole ly wi th

A-de c e qu ipm en t a nd m ay no t b e d isc los ed ex plo ite d, or re pr od uc ed fo r a ny ot he r p ur po se s w ith ou t th e e xp re ss pe rm iss ion of A

-d ec

. A -d ec , In c.

do es no t g ua ra nte e c om pli an ce w ith ac cre dit ati on po lic ies or lo ca l, s tat e, an d/o r f ed er al co de s, inc lud ing , b ut no t lim ite d t o, the

A me ric an s w ith

D isa bil itie s A ct.

DATE: 3-16-26

MCS

1-

0-

7-

PR

EL

IM

IN

AR

Y

LA

YO

U T

FO

R

VA

T

EM

PL

E

EX

PA

N

SI

O

N

DRAWN BY:

2.25.14 24X36 MGN.5A-DEC SGI

R re lia bl ec re at iv es ol ut io ns

36C25726Q0636 0001.pdf
VA Temple Expansion 3-16-26-PRELIMINARY
Sheets and Views
PRELIMINARY

File details come from the government source that posted it. Updated .