Bldg60InspMgmtPlan_Update2014FINAL JC.pdf
PDF 18 MB Posted
- Solicitation number
- 36C25725R0048
About this file
This document is an Asbestos Inspection and Management Plan for Building 60 at the VA Medical Center in Dallas, Texas, prepared by Micro Air of Texas, Inc. The comprehensive asbestos survey was originally conducted in November 2010 and updated in November 2014, covering approximately 90,000 square feet of the Community Living Center. The inspection identified multiple homogeneous material areas, with two confirmed asbestos-containing materials: brown HVAC seam sealant (HA-05) and pink sink soundproofing (HA-20), totaling approximately 3,004 square feet of asbestos-containing materials.
The document details the facility's construction (originally built in 1984 with a C-Wing added in 2010), describes the building's interior finishes, and outlines the methodology for sampling and analyzing building materials. The report includes recommendations for ongoing maintenance, six-month visual inspections, and three-year reassessments, in compliance with AHERA (Asbestos Hazard Emergency Response Act) guidelines. Multiple areas in the A and B Wings were partially renovated in 2014, with new building materials installed that were tested and confirmed to be non-asbestos-containing.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25725R0048 0003.docx | DOCX document | |
| Bldg 60 LBP Survey Report FINAL.pdf | ||
| CONSTRUCTION SAFETY PIN 2025.pdf | ||
| 36C25725R0048 0002.docx | DOCX document | |
| 36C25725R0048 Conformed Through Amendment A0001.pdf | ||
| 36C25725R0048 0001.docx | DOCX document | |
| 36C25725R0048_1.docx | DOCX document | |
| Specs and drawings - SCAN0003.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA MEDICAL CENTER
DALLAS, TEXAS
BUILDING 60
A.H.E.R.A. ASBESTOS INSPECTION
MANAGEMENT PLAN
3-YEAR REASSESSMENT & UPDATE - 2014
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
MICRO AIR PROJECT # B-1403
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P. O. Box 1225 Dickinson, TX 77539
(281) 280-9965
DALLAS, TEXAS
AHERA
ASBESTOS INSPECTION
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P. O. Box 1225 Dickinson, TX 77539
(281) 280-9965
Original Inspection Dates: November 15-17, 2010
Individual Asbestos Consultant: ________________________
DSHS License # 10-5436
TABLE OF CONTENTS
Page #
General Inventory Management Plan Format
Section I - AHERA Asbestos Inspection General Information
Introduction, Required Information, & Facility Description 1 - 3
Section II - Asbestos Methodology & Lab Analytical Report
Methodology 1 Classification 1 Limitations 2 Homogeneous Sampling Area Summary Table 3 - 6 Laboratory Report Sample Location Drawing(s) Homogeneous Area Location Drawing(s)
Section III - ACM Material Assessment & Quantification
General Information 1 Surfacing Materials 2 Thermal System Insulation Materials 2 - 4 Miscellaneous Materials 5 - 14 Photos of Asbestos-containing Homogeneous Areas
Section IV - Asbestos Material Response Action Recommendations
Introduction 1 Response Action Prioritization 2 Response Action Recommendations 3
Section V - Operations & Maintenance Program
Purpose 1 Scope 1 Facility ACM 2 Operations & Maintenance Recommendations 3 - 4 O&M Activities 5
Section VI - Facility Owner / Designated Person(s)
Licenses and Training Certificates
Section VII - Six Month Surveillance Documentation
Section VIII - Three Year Reinspection Updates
Section IX - Response Actions
BUILDING INSPECTION FOR FRIABLE AND NON-FRIABLE ACM
GENERAL INVENTORY
FACILITY ID: Building 60
ORIGINAL INSPECTION COMPLETION DATES: November 15 - 17, 2010 3-YEAR REASSESSMENT INSPECTION DATE: November 21, 2014
FACILITY ADDRESS: Building 60
VAMC
4500 S. Lancaster Road Dallas, TX 75216
TOTAL SQUARE FOOTAGE: APPROXIMATELY 90,000 SF
YEAR CONSTRUCTED: 1984 and an addition was added in 2010
USE OF FACILITY: Community Living Center
DESIGNATED PERSON: Thomas Rattler or Ken Taylor
ENGINEERING PHONE: 214-857-1069 - Contact Charles Ballard
INSPECTION COMPANY: MICRO AIR OF TEXAS, INC.
P. O. BOX 1225
DICKINSON, TEXAS 77539
PHONE: (281) 280-9965
NAME OF ACCREDITED PERSONS
PERFORMING INSPECTION: JENNIFER MCMILLIN (DSHS LICENSE # 60-1893)
ACCREDITATION AGENCY: TEXAS DEPT. OF STATE HEALTH SERVICES
ACCREDITATION #: N/A
THIS BUILDING CONTAINS:
1. FRIABLE ACBM
2. NON-FRIABLE ACBM X
3. FRIABLE MATERIAL
(ASSUMED TO BE ACBM)
4. NON-FRIABLE MATERIAL
(ASSUMED TO BE ACBM)
5. NONE OF THE ABOVE
_______________________________________ 12/10/10 & 11/21/14
ACCREDITED INSPECTOR DATE
DSHS LICENSE # 60-1893
_______________________________________ 11/21/14
ACCREDITED INSPECTOR DATE
DSHS LICENSE # 60-1893
BUILDING 60
DALLAS, TX
A.H.E.R.A. ASBESTOS INSPECTION &
MANAGEMENT PLAN
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
MICRO AIR PROJECT # B-1403
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P. O. BOX 1225
DICKINSON, TEXAS 77539
MICRO AIR OF TEXAS, INC. BUILDING 60 - VA Medical Center; Dallas, TX
AHERA ASBESTOS INSPECTION & MANAGEMENT PLAN
P. O. Box 1225
Dickinson, TX 77539
MANAGEMENT PLAN FORMAT
SECTION I: This section contains general information regarding the AHERA survey and management plan, required information, and a facility description.
SECTION II: This section contains general information, sampling information, and Homogeneous Sample Area Summary. The laboratory analytical report for the bulk samples collected during the 2010 inspection have been included. Additionally, information on the survey report and classification of homogeneous areas is located in this section. Drawings depicting the locations of all bulk building material samples collected and asbestos-containing homogeneous area locations can be found in this sub-section.
SECTION III: This section contains material assessments and quantification which are used to develop the appropriate response actions for the management plan. Photographs of each asbestos-containing material identified has been included in this section.
SECTION IV: This section contains the recommended response actions for each type of ACM in the facility including recommendations for immediate abatement, if necessary. Immediate response action recommendations are prioritized.
SECTION V: This section contains an updated Operations and Maintenance Program for the facility.
This program includes recommendations for ongoing maintenance functions.
SECTION VI: This section has been reserved for informational purposes. This section includes the Facility Owner / Designated Person information, as well as the Re-inspection / Periodic Surveillance Schedule. All applicable licenses, certifications, and accreditations of the Inspector, Management Planner, and Laboratory performing services on this Management Plan are also included in this section.
SECTION VII: This section has been reserved for reports for the six month inspections, assessments, and any ambient air monitoring.
SECTION VIII: This section has been reserved for documentation obtained from three year re-inspections. Updates to the Management Plan are to be included in this section.
SECTION IX: This section has been reserved for the owner to reference abatement response action reports and building maintenance action (O&M) reports. All documentation from asbestos abatement activities should also be included in this section.
SECTION I
AHERA ASBESTOS INSPECTION
SECTION I - GENERAL INFORMATION
INTRODUCTION
Micro Air of Texas, Inc. (Micro Air) was contracted by the Veterans Administration North Texas Health Care System (VANTHCS) located in Dallas, Texas to perform an asbestos inspection and generate a management plan in accordance with guidelines established in 40 CFR 763, the Asbestos Hazard Emergency Response Act of 1987 (AHERA), for the Veterans Administration Medical Center (VAMC) located in Dallas, Texas. This facility consists of numerous buildings constructed between 1940 and 2010. This particular report pertains to Building 60, the Community Living Center.
Micro Air performed a comprehensive asbestos survey of Building 60 on November 15 - 17, 2010. After the comprehensive asbestos survey results were compiled, a Management Planner accredited by an EPA-approved training provider and licensed as an Individual Asbestos Consultant in the state of Texas, reviewed the analytical results of the inspection and current physical condition assessments. The management planner then determined the potential hazard posed by the ACM and evaluated and selected control / response options based on all compiled information. This information was then composed and written into a final report.
In 2014, Micro Air of Texas conducted a 3-Year Asbestos Re-assessment and Inspection of all buildings located at the Dallas VAMC. Building 60 is currently known as the VA Nursing Home. Since the Original Asbestos Inspection in 2010, multiple areas in the A and B Wings of Building 60 were partially renovated in 2014. The renovated areas include the following:
A140, A141, A144, A170, A171, A174, B140, B141, B142, B144, B170, B171, B173, and B174. Micro Air re-inspected this building, and as a result, additional bulk samples were collected from the renovated areas listed above, and the information obtained has been included in the 2014 asbestos management plan update.
The federal National Emission Standard for Asbestos (NESHAP) and the Texas Asbestos Health Protection Act (TAHPA) both require that prior to any demolition or renovation activity in a building, a thorough inspection of the affected facility or part of the facility where the demolition or renovation operation will occur, must be performed for the presence of asbestos, including Category I and Category II non-friable asbestos-containing material (ACM).
Additionally, TAHPA requires that a minimum of three samples be collected from each homogeneous sampling area (material type) identified in the building. The work area and immediately surrounding areas which could foreseeably be disturbed by the actions necessary to perform the project must be inspected and sampled as applicable prior to renovations or demolition. While the VANTHCS is not subject to the TAHPA regulation, due to its exclusion as a federal facility, Micro Air collected bulk samples in accordance with TAHPA and AHERA protocol at the request of the VANTHCS engineering personnel.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 1
REQUIRED INFORMATION
In accordance with AHERA protocol, the VAMC located in Dallas, Texas is required to name a person who shall be responsible for implementation of the management plan (Designated Person - see Section V). Per the Occupational Safety and Health Administration (OSHA) 1926.1101, construction industry standard, maintenance personnel should be made aware of the types and locations of all facility ACM. These employees are required to have adequate asbestos awareness training (minimum 2 hours), and all maintenance personnel who may come in contact with or disturb ACM are required to receive a minimum of 16 hours of asbestos training in asbestos hazards and recognition of ACM. If the owner wishes to perform ACM activities with its own personnel, the owner is responsible for obtaining the required EPA training in accordance with the Model Accreditation Plan (MAP), which is located in Appendix C, Subpart E of 40 CFR, 763 (AHERA). Additionally, all OSHA requirements must be met, as well (i.e., asbestos physical, etc.). Otherwise, it is recommended that all ACM activities be performed by a Texas licensed Asbestos Contractor, and project oversight be conducted by a Texas licensed Asbestos Consultant Agency.
In accordance with the VA directive to comply with AHERA, the entire facility must be re-inspected and a reassessment of ACM conducted by an accredited inspector at least once every three years, and the management plan should be updated by a licensed Asbestos Inspector / Management Planner or Individual Asbestos Consultant. Additionally, visual inspections of the ACM must also be made by the Designated Person for the facility at least once every six months to determine whether any areas of the material have changed in condition, or if there are any other factors which may necessitate abatement actions.
FACILITY DESCRIPTION
Building 60 is approximately 90,000 square feet in size, and it serves as the Community Living Center. The construction date of the original section of the building is believed to be 1984 and the C-Wing was added in 2010. The Community Living Center is red-brick exterior construction on a slab foundation with a flat tar and gravel roof. No basement or crawl space is associated with the Community Living Center. There are 3 small mechanical rooms located above each wing of the building, primarily for HVAC equipment.
Interior finishes include vinyl (faux wood) floor tile in most of the patient areas, ceramic tile in the restrooms, and carpet in the offices. Walls are primarily sheetrock. Ceilings are lay-in ceiling tile throughout the building.
Steam pipe insulation in the Community Living Center appears to be fiberglass wrapped with paper and white mastic, and PVC elbows. HVAC ducts are metal with fiberglass and paper with white mastic wrap. Metal ducts were observed to have gray or brown sealant on the seams. Vibration joints were observed to be rubber.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 2
In 2014, the A-Wing and B-Wing of Building 60 had multiple renovations to nursing stations around the courtyard, and new interior building materials were installed. The approximate size of Building 60 remained the same after renovation. The finishes of the new additions include new sheetrock walls, ceilings, and ceiling tiles, cove base and adhesive, and new flooring materials.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 3
SECTION II
SECTION II- ASBESTOS LABORATORY ANALYTICAL REPORT
METHODOLOGY
Micro Air of Texas, Inc. performed a comprehensive asbestos survey of Building 60 on November 15 - 17, 2010 in accordance with AHERA and TAHPA sampling protocol and assessment factors. The inspection was performed by Jennifer McMillin, an accredited asbestos inspector who is licensed as a Building Inspector by the state of Texas (license #60- 1893). Micro Air of Texas, Inc. is licensed as an Asbestos Consulting Agency (#10-0110). All samples collected during this inspection were analyzed by J Resources, Inc., whose laboratory3 is accredited by the National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP) program (accreditation #200525-0) and licensed by the state of Texas (license #30-0273). Laboratory analysis of collected samples was performed in accordance with EPA and NVLAP prescribed methodologies for Polarized Light Microscopy of bulk material samples for the presence of asbestos. The results of laboratory analysis of collected bulk material samples are included in this section for reference.
A total of 109 bulk material samples were collected and analyzed by PLM during this comprehensive survey. Federal regulations require that each identifiable layer of an individual bulk building material sample be analyzed separately for asbestos content. In addition, federal regulations state that if any one sample from a homogeneous area is found to be asbestos-containing, then the entire homogeneous area is considered asbestos-containing, regardless of the results from the remaining samples from that homogeneous area.
On November 21, 2014, Micro Air of Texas conducted a 3 Year Asbestos Re-assessment and Inspection on Building 60, and bulk building material samples were collected from the newly renovated areas (listed above). The inspection was performed by Jennifer McMillin and Melissa Kiser (a DSHS Licensed Individual Asbestos Consultant #10-5436). A total of 24 bulk building material samples were collected and analyzed by PLM during this comprehensive survey. All of the samples were analyzed by J Resources, Inc.3
CLASSIFICATION
All materials which were sampled as being suspect for containing asbestos or were assumed to be asbestos-containing were grouped by sample type into Homogeneous Sampling Areas for purposes of assessment and quantification. Homogeneous materials are those which have similar appearance, texture, and function. If the inspector believes these materials to be the same, even if they are located in separate areas of a building, they may be grouped into the same sampling set. For purposes of this inspection report, the Homogeneous Area is designated as : HA. Each Homogeneous Area is given a number to distinguish it from other Homogeneous Areas (Example: HA-01A).
A CAD drawing(s) demonstrating the location of each collected bulk building material sample has been included in this section, as well as a CAD drawing(s) depicting the location of asbestos-containing homogeneous areas.
LIMITATIONS
Micro Air’s scope of services was limited primarily to accessible interior building materials.
While Micro Air made every effort to perform a thorough survey, the possibility exists that materials containing asbestos were not identified, inaccessible, or different from those identified at other locations. The findings and opinions presented are indicative of conditions on the date of our site inspection and should not be relied upon to represent conditions at substantially later dates, due to possible changes in the condition of building materials, renovations, and repairs. Additionally, most of the buildings located at this VA facility have steam pipes running underground to supply heat to each building. This material was inaccessible at the time of this inspection. All pipes located in wall chases, underground, in the crawlspace of a building, etc., is assumed to be ACM until tested and proven otherwise.
VAMC - DALLAS, TX
HOMOGENEOUS SAMPLE AREA SUMMARY
THE FOLLOWING TABLE DENOTES THE HOMOGENEOUS AREAS
IDENTIFIED IN BUILDING 60. THE TABLE INDICATES THE NUMBER OF
BULK BUILDING MATERIAL SAMPLES COLLECTED FOR EACH
HOMOGENEOUS AREA AND WHETHER THE HOMOGENEOUS AREA WAS
ASBESTOS-CONTAINING. ADDITIONALLY, ESTIMATED QUANTITIES OF
THE VARIOUS BUILDING MATERIALS SAMPLED HAVE ALSO BEEN
INCLUDED IN THE TABLE.
VAMC; DALLAS, TX
HOMOGENEOUS SAMPLE AREA SUMMARY
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-01 Sprayed-On Fire Proofing, Gray
No 5 1000 SF
HA-02 White Mastic and White/Silver Wrap on
Yellow Fiberglass Pipe Insulation with PVC
Joints
No 19 20,000 LF
HA-03 HVAC Duct Insulation, Fiberglass with White
Mastic
No 7 5000 SF
HA-04 Gray HVAC Seam Sealant
No 5 150 SF
HA-05 Brown HVAC Seam Sealant
Yes 6 3000 SF
HA-06 Sheetrock & Joint Compound
No 12 200,000 SF
HA-07 12" x 12" Floor Tile, White w/ Beige & Gray
Streaks and Black Mastic (Type I)
No 5 8500 SF
HA-08 12" x 12" Floor Tile, White w/ Pastel Specks and Yellow Mastic (Type II)
No 3 800 SF
HA-09 Vinyl Sheet Flooring, Faux Wood, Dark in
Color with Brown Mastic (Type III)
No 6 26,000 SF
HA-10 12" x 12" Floor Tile, White, Gray & Black Terrazzo Style with
Yellow Mastic (Type IV)
No 3 300 SF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 4
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-11 16" x 16" Floor Tile, Brown & Tan Marbled with Yellow Mastic
(Type V)
No 3 17,000 SF
HA-12 Vinyl Sheet Flooring, Wood Look, Light in
Color (Type VI)
No 3 1500 SF
HA-13 12" x 12" Floor Tile, Light Tan w/ Beige Streaks and Yellow Mastic (Type VII)
No 4 500 SF
HA-14 4' x 2' Ceiling Tile, White with Fissures & Pinholes
(Type I)
No 3 41,000 SF
HA-15 2' x 2' Ceiling Tile, White with Fissures & Pinholes
(Type II)
No 3 3000 SF
HA-16 2' x 2' Ceiling Tile, White Vinyl over Sheetrock
(Type III)
No 3 1008 SF
HA-17 2' x 2' Ceiling Tile, Textured White (Type
IV)
No 3 12,000 SF
HA-18 Cove Base Adhesive, Tan
No 5 10,000 LF
HA-19 Gray Sink Soundproofing No 2 4 SF
HA-20 Pink Sink Soundproofing Yes 2 4 SF
HA-21 White Sink Soundproofing
No 3 6 SF
HA-22 Red Fire Stop No 4 500 SF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 5
NOTE: DURING THE RENOVATION OF BUILDING 60 IN 2014, NO ASBESTOS-CONTAINING
BUILDING MATERIALS EXISTED IN THE AREAS THAT WERE RENOVATED. MULTIPLE
NURSING STATIONS LOCATED IN THE A AND B WINGS WERE PARTIALLY RENOVATED,
AND NEW BUILDING MATERIALS WERE INSTALLED. BELOW IS A SUMMARY TABLE OF
THE NEWLY INSTALLED BUILDING MATERIALS, WHICH WERE SAMPLED, TESTED, AND
DETERMINED NOT TO CONTAIN ACM.
VAMC; DALLAS, TX
BUILDING 3
NOVEMBER 11, 2014 ASBESTOS INSPECTION
HOMOGENEOUS SAMPLE AREA SUMMARY
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-60-1401 Sheetrock and Joint Compound
No 6 5,000 SF
HA-60-1402 2' x 2' White Ceiling Tile With Pinholes and
Fissures
No 6 1,000 SF
HA-60-1403 Tan Vinyl Peel & Stick Flooring With Gray Mastic
No 6 1,000 SF
HA-60-1404 Tan Cove Base Adhesive No 6 500 LF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Building 60 6
Date Received: 23-Nov-2010 29-Nov-2010Date Analyzed:
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Fibrous GlassFire Proofing, Gray, Homogeneous None DetectedA1001-60-01 56%
Other Non-Fibrous Material 44%
Fibrous GlassFire Proofing, Gray, Homogeneous None DetectedA1001-60-02 56%
Other Non-Fibrous Material 44%
Fibrous GlassFire Proofing, Gray, Homogeneous None DetectedA1001-60-03 56%
Other Non-Fibrous Material 44%
Fibrous GlassFire Proofing, Gray, Homogeneous None DetectedA1001-60-04 56%
Other Non-Fibrous Material 44%
Fibrous GlassFire Proofing, Gray, Homogeneous None DetectedA1001-60-05 56%
Other Non-Fibrous Material 44%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, Beige/ Silver, Homogeneous
None DetectedA1001-60-06 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 1 of 25
Lab DirectorLee W. Poye
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, Beige/ Silver, Homogeneous
None DetectedA1001-60-07 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-08 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Paper Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-09 60% 20%
Other Non-Fibrous Material 20%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 2 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-10 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-11 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-12 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 3 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-13 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
WollastoniteLAYER 1 Mastic Wrap, Beige, Homogeneous
None DetectedA1001-60-14 <1%
Other Non-Fibrous Material 100%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Wollastonite Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, Beige/ Silver, Homogeneous
None DetectedA1001-60-15 <1% 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 4 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White, Homogeneous
None DetectedA1001-60-16 45% 10%
Other Non-Fibrous Material 45%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White, Homogeneous
None DetectedA1001-60-17 45% 10%
Other Non-Fibrous Material 45%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White, Homogeneous
None DetectedA1001-60-18 45% 10%
Other Non-Fibrous Material 45%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 5 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White, Homogeneous
None DetectedA1001-60-19 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-20 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-21 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 6 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-22 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-23 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-24 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 7 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-25 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-26 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-27 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 8 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-28 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-29 30% 10%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Cellulose Fiber Fibrous Glass Wollastonite
LAYER 1
Mastic Wrap, White/ Silver, Homogeneous
None DetectedA1001-60-30 30% 10% <1%
Other Non-Fibrous Material 60%
Fibrous GlassLAYER 2 Insulation, Yellow, Homogeneous
None Detected 98%
Other Non-Fibrous Material 2%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 9 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Cellulose Fiber Fibrous Glass Wollastonite
Mastic, White, Homogeneous None DetectedA1001-60-31 <1% <1% <1%
Other Non-Fibrous Material 100%
Sealant, Gray, Homogeneous None DetectedA1001-60-32 Other Non-Fibrous Material 100%
Sealant, Gray, Homogeneous None DetectedA1001-60-33 Other Non-Fibrous Material 100%
Sealant, Gray, Homogeneous None DetectedA1001-60-34 Other Non-Fibrous Material 100%
Sealant, Gray, Homogeneous None DetectedA1001-60-35 Other Non-Fibrous Material 100%
Sealant, Gray, Homogeneous None DetectedA1001-60-36 Other Non-Fibrous Material 100%
Sealant, Brown, Homogeneous ChrysotileA1001-60-37 2% Other Non-Fibrous Material 98%
Sealant, Brown, Homogeneous ChrysotileA1001-60-38 2% Other Non-Fibrous Material 98%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 10 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
Sealant, Brown, Homogeneous ChrysotileA1001-60-39 2% Other Non-Fibrous Material 98%
Sealant, Brown, Homogeneous ChrysotileA1001-60-40 2% Other Non-Fibrous Material 98%
Sealant, Brown, Homogeneous ChrysotileA1001-60-41 2% Other Non-Fibrous Material 98%
Sealant, Brown, Homogeneous ChrysotileA1001-60-42 2% Other Non-Fibrous Material 98%
LAYER 1
Painted Texture, White, Homogeneous
None DetectedA1001-60-43 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-44 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 11 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-45 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-46 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 12 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-47 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-48 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 13 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
LAYER 1
Painted Texture, White, Homogeneous
None DetectedA1001-60-49 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
LAYER 1
Painted Texture, White, Homogeneous
None DetectedA1001-60-50 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 14 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
LAYER 1
Texture, White, Homogeneous
None DetectedA1001-60-51 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Cellulose FiberWallboard, Brown/ White, Homogeneous None DetectedA1001-60-52 10%
Other Non-Fibrous Material 90%
Cellulose FiberWallboard, Brown/ White, Homogeneous None DetectedA1001-60-53 10%
Other Non-Fibrous Material 90%
LAYER 1
Painted Texture, White, Homogeneous
None DetectedA1001-60-54 Other Non-Fibrous Material 100%
Cellulose FiberLAYER 2 Tape, Beige, Homogeneous
None Detected 100%
LAYER 3
Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose FiberLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10%
Other Non-Fibrous Material 90%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 15 of 25
JH1037319J3 Order #:
VAMC BLDG 60
PO Box 1225 Dickinson TX 77539
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Sample Description Asbestos Constituents
Sample ID # Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
29-Nov-2010Date Reported:
LAYER 1
Floor Tile, White/ Tan, Homogeneous
None DetectedA1001-60-55 Other Non-Fibrous Material 100%
LAYER 2
Mastic, Black, Homogeneous
None Detected Other Non-Fibrous Material 100%
LAYER 1
Floor Tile, White/ Tan, Homogeneous
None DetectedA1001-60-56 Other Non-Fibrous Material 100%
LAYER 2
Mastic, Black, Homogeneous
None Detected Other Non-Fibrous Material 100%
LAYER 1
Floor Tile, White/ Tan, Homogeneous
None DetectedA1001-60-57 Other Non-Fibrous Material 100%
LAYER 2
Mastic, Black, Homogeneous
None Detected Other Non-Fibrous Material 100%
LAYER 1
Floor Tile, White/ Tan, Homogeneous
None DetectedA1001-60-58 Other Non-Fibrous Material 100%
LAYER 2
Mastic, Black, Homogeneous
None Detected Other Non-Fibrous Material 100%
LAYER 1
Floor Tile, White/ Tan, Homogeneous
None DetectedA1001-60-59 Other Non-Fibrous Material 100%
LAYER 2
Mastic, Black, Homogeneous
None Detected Other Non-Fibrous Material 100%
Tracy Morgan Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3).
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .