VA TEM FA ADDENDUM 1 Drawings Phase 2 signed.pdf

PDF 19 MB Posted

Attached to
Y1DA--674-22-801 Upgrade Fire Alarm System Phase 2 Federal contract opportunity
Solicitation number
36C25722B0021
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This document provides details for a federal contract solicitation to upgrade the fire alarm system at the Temple VA medical center in Temple, Texas. The solicitation number is 36C25722B0021 and concerns project number 674-22-801 to upgrade the fire alarm system in Phase 2. The purpose of the project is to upgrade the fire alarm system in Phase 2 at the Temple VA located at 1901 Veterans Memorial Drive in Temple, Texas. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--674-22-801 Upgrade Fire Alarm System Phase 2, newest first.
File Type Posted
36C25722B0021 0012.docx DOCX document
Temple Fire Alarm Phase II - Addendum 002.pdf PDF
204 Mechanical Drawings.pdf PDF
Building 202 with existing mechanical drawings.pdf PDF
163 Mechanical drawings.pdf PDF
2nd set of RFIs 36C25722B0021 Upgrade Fire Alarm System.docx DOCX document
36C25722B0021 0011.docx DOCX document
36C25722B0021 0010.docx DOCX document
36C25722B0021 0009.docx DOCX document
36C25722B0021 0008.docx DOCX document
36C25722B0021 0007.docx DOCX document
Sign in sheet for 2nd Site visit .pdf PDF
36C25722B0021 0006.docx DOCX document
RFIs 36C25722B0001 Upgrade Fire Alarm System Phase 2.docx DOCX document
VA TEM FA ADDENDUM 1 Specifications Phase 2.pdf PDF
Submittal 28 31 00 PD 00 Fire Alarm Product Data.pdf PDF
Professional Seals FPE signed.pdf PDF
VA TEM FA ADDENDUM 1 Narrative Phase 2.pdf PDF
Submittal 28 31 00 PD2 00 Fire Alarm Product Data.pdf PDF
36C25722B0021 0005.docx DOCX document
Temple Phase II Addendum 1 Summary.doc DOC document
Responses RFI Upgrade Fire Alarm System Phase 2.docx DOCX document
36C25722B0021 0004.docx DOCX document
36C25722B0021 0003.docx DOCX document
36C25722B0021 0002.docx DOCX document
36C25722B0021 0001.docx DOCX document
36C25722B0021_1.docx DOCX document
VA TEMPLE PHASE II - DESIGN NARRATIVE_01.pdf PDF
VA TEMPLE PHASE II - BID SET SPECS_SIGNED_01.pdf PDF
VA TEMPLE PHASE II - BID SET SUBMISSION_SIGNED_01.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Above finished floor AFF Acoustic ACST Acoustic Panel Ceiling APC Addendum ADD Alternate ALT Aluminum AL Angle L Approximate APPROX Architecture, architectural ARCH Asbestos ASB Asphalt ASPH Assistant ASST Association ASSN Automatic AUTO Average AVG Base plate BP Basement BSMT Beam BM Bearing BRG Bedroom BR Benchmark BM Board BD Boiler BLR Bottom BOT Brick BRK Building line BL Building BLDG Built-up-roof BUR Cabinet CAB Carpet CPT Catalog CAT Ceiling height CH Ceiling CLG Center CTR Centerline CL Ceramic Tile CT Ceramic CER Chalkboard CB Clear CLR Closet CLO Coated CTD Cold rolled CR Column COL Company CO Composition COMP Concrete Masonry Unit CMU Concrete CONC Construction joint CJ Construction CONSTR "Continue, Continuous" CONT Corridor CORR Countersink CSK Cubic CU Curve(d) CRV Dampproofing DP Degree DEG Department(al) DEPT Detail DET Diagonal DIAG Diameter DIA Dimension DIM Dishwasher DW Dispenser DISP Door DR Double DBL Double-hung DH Down DN Downspout DS Drain DR Drawing DWG Each EA East E Electric Water Cooler EWC "Electric, electrical" ELEC Elevation EL Elevator ELEV Engineer ENGR Entrance ENTR Equal EQ Equipment EQUIP Exhaust EXH Existing EXIST Expansion joint EXP JT Exposed EXP Exterior EXT Fabricate FAB Face of Stud F. OF S.

Fan Coil Unit FCU Fiberglass-reinforced plastics FRP Finish FIN Finished Floor FF Fire Extinguisher FE Fire Extinguisher & Cabinet FEC Fire Retardant Treated FRT Fireproof FPRF Fixture FXTR Flange FLG Flashing FL Floor FL Floor drain FD Flooring FLG Fluorescent FLUOR

Footing FTG Foundation FDN Furnish(ed), furniture FURN Furring FURR Gage (gauge) GA Galvanize(d) GALV Galvanized Iron GALVI Glazed Wall Tile GWT Grab Bar GB Grade GR Gravel GVL Gypsum Wallboard GWB Gypsum GYP Handicapped HC Hardware HDW Heating ventilating and HVAC air conditioning Height HGT High Point HPT High Performance HP High Performance Coating HPC Hollow Metal HM Horizontal HORIZ Include(d), inclusive INCL Incorporated INC Information INFO Inside diameter ID Install(ed), installation INSTL Insulation INSUL Interior INT Janitor JAN Joint JT Joist J, JST Junction box JB Knock down KD Laboratory LAB Lavatory LAV Left Hand LH Left L Length LG Level LVL Light LT Machine MACH Maintenance MAINT Manager MGR Manual MNL Manufacturing MFG Markerboard MB Masonry opening MO Masonry MSNRY Master bedroom MBR Material MATL Maximum MAX Mechanical MECH Membrane MEMB Men M Metal MET, MTL Mezzanine MEZZ Minimum MIN Mirror MIR Miscellaneous MISC Mounted MTD Mounting MTG Necessary NEC Noise-reduction coefficient NRC Nominal NOM Non Combustible NC, NONCOM North N Not in Contract NIC Not to scale NTS Not available NA Number NO Office OFF On center OC Opening OPNG Opposite OPP Outside diameter OD Overall OA Overhead OVHD Page P Painted PTD Pair PR Panel PNL Partition PTN Percent PCT Perforate(d) PERF Permanent PERM Perpendicular PERP Piece PC Plastic Laminate PLAM Plastic Laminate PLAS.LAM Plate PL Plumbing PLMB Plywood PLYWD Point PT Polyvinyl chloride PVC Precast PRCST Prefabricated PREFAB Preliminary PRELIM Preparation, prepare PREP Program PRGM Projection Screen PS

Project PROJ Property PROP Public Address PA Quality control QC Quality QUAL Quantity QTY Quarry Tile QT Radius RAD Rain Leader RL Received RCVD Receptacle RCPT Receptionist RECPT Recess(ed) REC Refer, reference REF Refrigerate, refrigerator REFR Reinforce REINF Reinforced concrete RC Remove RMV Repair RPR Required REQD Revise, revision REV Right hand RH Road RD Roof Drain RD Roof RF Roofing RFG Room RM Rubber tile floor RTF Rubber RBR Schedule SCHED Schematic SCHEM Section SECT Service SVCE "Sheet, sheeting" SHT Shower SH Siding SDG Similar SIM Slope SL Sound-transmission class STC South S Speaker SPKR Specification SPEC Sprinkler SPR Square SQ Stainless steel SS Standard STD Standpipe SP Steel STL Storage STOR Structural Glazed Facing Tile SGFT Structural, structure STRUCT Substitute SUBST Surface SURF Suspend(ed) SUSP Switch SW Symmetrical SYM System SYS Tackboard TB Tackstrip TS Telephone TEL Television TV Temporary TEMP Terrazzo TER Thick THK Through THRU Toilet T Tongue and groove T&G Top and bottom T&B Top chord TC Top of Masonry Parapet TMP Top of Bearing TOFB Top of Steel T.O.S.

Topping TOPG Total TOT Transformer XFMR Transom TR Transparent TRANS Tread TRD Threshold THRESH Typical TYP Underground UG Underwriters Laboratories UL Unfinished UNF Unit Ventilator UV Unless Otherwise Noted UON Urinal UR US Gypsum Company USG Vertical VERT Vestibule VEST, V Vinyl Reducing Strip VRS Vinyl Composite Tile VCT Vinyl asbestos tile VAT Wardrobe WARD Water closet WC Waterproof WP Weight WT Welded WLD Welded Wire Mesh WWM With W/ Without W/O Women W Wood WD Wrought Iron WI

A100A

SIM

A101

SIM

DEPT.

ADD

GRID LINES

SECTIONS

DETAIL NUMBER

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

DETAILS IN PLAN/SECTION

ROOM NUMBER

DOOR NO. ON PLAN

H.M. FRAME

NO. ON PLAN

REVISION: TYPE =

A.S.I/P.R./C.C.D./ADD.

CASEWORK

(FURNISHING PLANS ONLY)

ALUM. FRAME/WINDOW

TYPE

WALL TYPE

# # INTERIOR ELEVATION

DETAIL NUMBER

SHEET NUMBER

A3

ROOM NAME

B101a

BOUNDARY INDICATES

BUILDINGS INCLUDED IN

THIS PACKAGE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

Drawing of

11/09/2021

100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

674-22-801

CSSDLO

COVER SHEET

GI001

-2

-8

G I0

/0

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

Fire Alarm Campus Upgrade Phase II

100% CD Submission 674-22-801

Temple VA Medical Center 1901 Veterans Memorial Drive

Temple, TX 76504

204-E101 ELECTRICAL PLAN – LEVEL 1 X X

202-E101 ELECTRICAL PLAN – LEVEL 1 X X

163-E101 ELECTRICAL PLAN – LEVEL 1 X X

ELECTRICAL:

204-FA106-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA K X X

204-FA106-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA J X X

204-FA106-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA G X X

204-FA106 BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 X X

204-FA105-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA K X X

204-FA105-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA J X X

204-FA105-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA G X X

204-FA105 BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 X X

204-FA104-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA K X X

204-FA104-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA J X X

204-FA104-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA G X X

204-FA104 BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 X X

204-FA103-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA K X X

204-FA103-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA J X X

204-FA103-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA G X X

204-FA103 BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 X X

204-FA102-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA K X X

204-FA102-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA J X X

204-FA102-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA G X X

204-FA102 BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 X X

204-FA101-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA K X X

204-FA101-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA J X X

204-FA101-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA G X X

204-FA101 BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 X X

204-FA100-G BUILDING 204 - FIRE ALARM PLAN - BASEMENT LEVEL - AREA G X X

204-FA100 BUILDING 204 - FIRE ALARM PLAN - BASEMENT LEVEL X X

204-FA001 BUILDING 204 - FIRE ALARM GENERAL NOTES AND DETAILS X

202-FA102-D BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA D X X

202-FA102-C BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA C X X

202-FA102-B BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA B X X

202-FA102-AF BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA AF X X

202-FA102 BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 X X

202-FA101-EW BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA EW X X

202-FA101-EE BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA EE X X

202-FA101-D BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA D X X

202-FA101-C BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA C X X

202-FA101-B BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA B X X

202-FA101-AF BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA AF X X

202-FA101 BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 X X

202-FA001 BUILDING 202 - FIRE ALARM GENERAL NOTES AND DETAILS X

163-FA105 BUILDING 163 - FIRE ALARM PLAN - LEVEL 5 - OVERALL X X

163-FA104 BUILDING 163 - FIRE ALARM PLAN - LEVEL 4 - OVERALL X X

163-FA103 BUILDING 163 - FIRE ALARM PLAN - LEVEL 3 - OVERALL X X

163-FA102-D BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA D X X

163-FA102-CM BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA CM X X

163-FA102-C BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA C X X

163-FA102-AB BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA AB X X

163-FA102 BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - OVERALL X X

163-FA101-BCD BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA BCD X

163-FA101-BC BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA BC X

163-FA101-ABD BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA ABD X

163-FA101-AB BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA AB X

163-FA101 BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - OVERALL X X

163-FA100-BCD BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BCD X X

163-FA100-BC BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BC X X

163-FA100-ABD BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA ABD X X

163-FA100-AB BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA AB X X

163-FA100 BUILDING 163 - FIRE ALARM PLAN - BASEMENT - OVERALL X X

163-FA001 BUILDING 163 - FIRE ALARM GENERAL NOTES AND DETAILS X

FIRE PROTECTION:

GI003 PENETRATION DETAILS X X

GI002 SITE ORIENTATION PLAN X

GI001 COVER SHEET X X X

GENERAL:

SHEET NUMBER SHEET NAME 35% 65% 100% 100% FINAL

DANIEL L. OLIG

144883

03FEB2023

CAMPUS MAIN FIRE

ALARM CONTROL PANEL

IN BUILDING 58 & 204

FACP RM 102

BUILDING 53

FACP RM 101

BUILDING 55

FACP

BUILDING 46

FACP RM A23

BUILDING 171

FACP RM 10

BUILDING 158

FACP RM E133

BUILDING 147

FACP RM 102

BUILDING 222

FACP RM C1-29

BUILDING 202

FACP W. WALL

BUILDING 62

FACP

BUILDING 58

FACP RM 1A-102 / RM 1C-102

BUILDING 221

FACP CORR. 115

BUILDING 220

FACP W. WALL

BUILDING 206

FACP RM 1R40

BUILDING 205

FACP RM 1G23

BUILDING 204

FACP CORR. 102

BUILDING 64

FACP RM C1-4

BUILDING 99

FACP CORR. C1

BUILDING 146

BUILDING 201

NOTE: BUILDINGS 200 AND 201 ARE NOT INCLUDED IN THE ALARM REPLACEMENT

SCOPE FOR THIS PROJECT. THESE BUILDINGS ARE MONITORED BY THE FIRE ALARM

CONTROL PANEL IN BUILDING 204. THESE BUILDINGS WILL NEED TO BE MONITORED

BY THE NEW ALARM CONTROL PANEL AND MAIN CONTROL UNITS.

FACP

BUILDING 47

BUILDING 200

FACP IN CORR.

B/W 46 & 47

FACP

BUILDING 44

FACP

BUILDING 45

BUILDINGS 208,

209, 210, 211, 212, 213, 214, 215, 216

FACP IN BLDG 204 RM 1G23

BUILDING 163

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

674-22-801

CSSDLO

SITE ORIENTATION PLAN

GI002

-2

-8

G I0

/2

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

204 Teague Hospital

202 Domicilliary, WTRC, Mental Health Clinic

163 Teague Tower Hosp. Clinics, Surg, Lab, Rad, cafeteria, gift store.

Building # Building Name

SCALE: NTS

A15

VA TEMPLE - SITE ORIENTATION PLAN

SCALE: NTS

C5

VA TEMPLE - CAMPUS FIRE ALARM RISER DIAGRAM

DANIEL L. OLIG

FIRE RESISTANT RATED WALL CONSTRUCTION

THROUGH PENETRATION FIRESTOPPING SYSTEM

PROVIDE SYSTEM IN ACCORDANCE WITH FIRESTOPPING SCHEDULE

WALL PENETRATION - SEE DRAWINGS

SLAB PENETRATION - SEE DRAWINGS

THROUGH PENETRATION FIRESTOPPING SYSTEM

PROVIDE SYSTEM IN ACCORDANCE WITH

FIRESTOPPING SCHEDULE

FIRE RESISTANCE RATED FLOOR CONSTRUCTION

FLOOR PIPE PENETRATION

UL No: F-L-1020

JOINT SEALANT APPLIED

WITHIN OPENING

METAL PIPE

CONCRETE OVER COMPOSITE

STEEL DECK

MINERAL WOOL INSULATION

JOINT SEALANT

JOINT SEALANT

MINERAL WOOL

INSULATION

METAL PIPE

FLOOR PIPE PENETRATION

UL No: F-L-5014

JOINT SEALANT APPLIED

WITHIN OPENING

METAL PIPE

CONCRETE OVER COMPOSITE

STEEL DECK

MINERAL WOOL INSULATION

JOINT SEALANT

JOINT SEALANT

MINERAL WOOL

INSULATION

GLASS FIBER INSULATION

GLASS FIBER

INSULATION

METAL PIPE

SINGLE CONDUIT/PIPE PENETRATION

UL No: W-L-1063

JOINT SEALANT

PIPE / CONDUIT

JOINT SEALANT

RATED WALL ASSEMBLY - VERIFY

WALL TYPE IN FIELD

48" MAX

V A

R

IE

S

6" M

A X

2" MAX, 1" MIN

1" M

A X

MULTIPLE CONDUIT/PIPE PENETRATIONS

UL No: W-L-1063

MINERAL WOOL INSULATION

WALL TYPE, SEE PLAN

MINERAL WOOD INSULATION

MINERAL WOOL INSULATION

WALL TYPE, SEE PLAN

WALL TYPE, SEE PLAN

SINGLE CONDUIT/PIPE PENETRATION

UL No: W-L-5044

PIPE/CONDUIT

FORMING MATERIAL

JOINT SEALANT

VERIFY WALL TYPE IN FIELD

JOINT SEALANT

PIPE / CONDUIT

WALL TYPE

SMALL PENETRATIONS IN PARTITIONS

RATED UP TO 2 HOURS

NO TREATMENT REQUIRED FOR UP

TO 1/8" GAP

MAXIMUM GAP 1/4"

MAXIMUM GAP 1/2", FILL TO FULL DEPTH

OF DRYWALL AND STRIKE OFF AT FACE

OF DRYWALL, DO NOT SPREAD BEYOND

OPENING

2'-0" (PER UL)

SHALLOW FIVE SIDED BOX

RATED WALL ASSEMBLY-

SEE PARTITION TYPES FOR

NUMBER OF LAYERS OF

GYPSUM BOARD

ELECTRICAL JUNCTION BOX

16 SQ INCH MAX OPENING

MAX 100 SQ INCHES IN 100 SQ FEET

LAMINATE BACK PIECE

TO WALLBOARD

REQUIRED BOX EXCEEDS 16 SQ INCHES

OR AGGREGATE SUM OF BOXES

EXCEEDS 100 SQ INCHES IN 100 SQ

FEET OF WALL AREA

ADJACENT ELECTRICAL BOXES

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

Drawing of

11/09/2021

100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

674-22-801

EWMDLO

PENETRATION DETAILS

GI003

-2

-8

G I0

/1

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: NTS

A5

THROUGH PENETRATION FIRESTOP SYSTEM KEY

SCALE: NTS

F6

PENETRATION DETAIL

SCALE: NTS

F3

PENETRATION DETAIL

SCALE: NTS

A9

PENETRATION DETAIL

SCALE: NTS

D9

PENETRATION DETAIL

SCALE: NTS

D6

PENETRATION DETAIL

SCALE: NTS

D3

PENETRATIONS

SCALE: NTS

F9

ELECTRICAL JUNCTION BOX DETAIL

DANIEL L. OLIG

F

S

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

CODE DATA

OCCUPANCY HEALTHCARE

SPRINKLERS FULLY SPRINKLERED

NOTIFICATION SPEAKERS, STROBES AND COMBINATION SPEAKER-STROBES IN

NORMALL OCCUPIED AREAS

DETECTION MANUAL PULL-STATIONS, SPRINKLERS, SMOKE DETECTOR AT

FACP, CO DETECTOR AT FUEL FIRED EQUIPMENT

FIRE ALARM

ZONING

FIRE ALARM SYSTEM ZONING TO MATCH EXISTING SMOKE

ZONES

1. PROVIDE AND INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT THE BUILDING

PER THE VA DESIGN GUIDE AND NFPA 72. REFER TO SPEC SECTION 28 31 00

INTERIOR FIRE ALARM SYSTEM. FIRE ALARM SYSTEM WILL BE ZONED PER SMOKE

COMPARTMENT.

2. ALL EXISTING FIRE ALARM DEVICES, PANELS AND RELATED EQUIPMENT ARE TO

BE DEMOLISHED. EXISTING ALARM SYSTEMS MUST REMAIN IN-SERVICE AND

FUNCTIONAL WHILE NEW ALARM SYSTEM IS INSTALLED. FOLLOW ILSM

PROTOCOLS FOR SHUTDOWN AND PHASE DEMO OF EXISTING ALARM SYSTEM SO

THAT REMOVAL ONLY OCCURS ONCE NEW ALARM SYSTEM IS FULLY INSTALLED

AND FUNCTIONAL.

3. THE NEW FIRE ALARM SYSTEM SHALL REPORT TO THE NEW MAIN GRAPHIC

ANNUNCIATORS THAT WERE INSTALLED IN BUILDING 58 AND THE POLICE ROOM IN

BUILDING 204 DURING PHASE I. SEE FIRE ALARM SITE PLAN FOR DETAILS.

4. COORDINATE FIRE ALARM SYSTEM DEVICE LOCATIONS WITH LIGHT FIXTURES,

STRUCTURAL MEMBERS, SPRINKLER HEADS AND PIPING, HVAC EQUIPMENT AND

DUCTWORK.

5. ALL EXISTING INTERFACING DEVICES (TAMPERS, FLOWS, PRESSURE SWITCHES,

ETC) WILL BE CONNECTED TO THE NEW FA SYSTEM AND REPORT TO THE MAIN

GRAPHIC ANNUNCIATORS IN BUILDINGS 58, AND 204. INTERFACING DEVICES ARE

SHOWN WHEN LOCATIONS ARE KNOWN, HOWEVER THE DRAWINGS SHOULD NOT

BE USED AS AN EXHAUSTIVE LIST.

6. ALL EXISTING DOOR HOLDING/CLOSING DEVICES TO BE TIED IN TO THE NEW FA

SYSTEM AND REPORT TO THE MAIN GRAPHIC ANNUNCIATORS. EXISTING

LOCATIONS ARE SHOWN WHERE THE CLOSER IS REQUIRED FOR SMOKE

COMPARTMENTS.

7. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND

SATISFACTORILY OPERATING SYSTEMS AS INDICATED ON THE CONTRACT

DOCUMENTS AND AS EVIDENTLY INTENDED. IT IS NOTED THAT THE DRAWINGS

ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND

WORK. INTERCONNECTIONS HAVE BEEN SHOWN, AND THE CONTRACTOR SHALL

FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO ACCOMPLISH THE

FUNCTIONS INDICATED. ADDITIONALLY, FIRE ALARM SYSTEMS HAVE BEEN

SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE REQUIRED

QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER

SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED

BY THE SYSTEM MANUFACTURER, THE SPECIFICATIONS, AND ANY APPLICABLE

CODES. ALL WIRING SHOWN ON RISER DIAGRAMS SHALL ALSO BE FURNISHED

AND INSTALLED REGARDLESS OF WHETHER THESE ITEMS ARE SHOWN ON THE

FLOOR PLANS.

8. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK

OF ALL OTHER TRADES AND EXISTING CONDITIONS SO AS TO AVOID CONFLICTS.

RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO

PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE

CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY

RESULT IN REJECTION OF THE WORK.

9. ADDITIONAL DEVICES MAY BE REQUIRED. DO NOT USE THESE DRAWINGS FOR

DEVICE COUNTS.

10. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION

INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY

TESTING LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING

JURISDICTION.

11. EXISTING CONDUIT IN GOOD CONDITION THAT HAS BEEN SALVAGED FROM OTHER

BUILDINGS MAY BE REUSED IF POSSIBLE AND SHALL BE STRIPED IN PATIENT

AREAS. NEW CONDUIT SHALL BE MARKED WITH RED COUPLINGS. ALL OTHER

MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED,

AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING

LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.

12. ALL FIRE ALARM CABLES SHOULD BE INSTALLED IN METAL RACEWAYS.

13. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES AND MAY

BE EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL

ROOMS. ALL RACEWAY AND WIRING SHALL BE ROUTED EITHER PERPENDICULAR

OR PARALLEL TO THE BUILDING'S STRUCTURAL COMPONENTS.

14. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND

INSTALLATION REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE

CONCEALED IN FINISHED SPACES AND LOCATIONS SHALL BE COORDINATED WITH

THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS.

15. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX,

CABINET, PULL BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL

AND CIRCUIT NUMBER, CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER

APPROPRIATE INFORMATION. ALL PULL AND JUNCTION BOXES SHALL BE LABELED

AS TO FUNCTION.

16. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS,

HANGERS, SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT

AND PREVENT EQUIPMENT MOVEMENT. ALL EQUIPMENT LOCATED IN SEISMIC

ZONES SHALL BE SECURED WITH MEANS APPROVED FOR THE SEISMIC

CLASSIFICATION ENCOUNTERED.

17. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED

WITH FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE

CONSTRUCTION TO BE PENETRATED. PROVIDE DOCUMENTATION ON ALL SUCH

PENETRATION SEALING SYSTEMS FOR VERIFICATION OF PROPER INSTALLATION.

18. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER

WATER OR MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH

APPROPRIATE SEALING FITTINGS OR SEALED CONSTRUCTION TO PREVENT THE

INTRODUCTION OF MOISTURE INTO THE BUILDING.

19. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH

ENDS AND FITTED WITH NYLON PULLSTRINGS FOR FUTURE USE.

20. ELECTRICAL WORK SHALL BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY TO

PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE. WHERE WORK

ON EXISTING SYSTEMS WILL REQUIRE INTERRUPTION OF ELECTRICAL SERVICE,

THEN TEMPORARY PROVISIONS ACCEPTABLE TO THE OWNER FOR TEMPORARY

POWER SHALL BE UTILIZED UNTIL THE WORK IS COMPLETE.

21. THE FIRE ALARM SYSTEM SHALL COMPLY WITH ALL RELATED NFPA, BUILDING

CODES AND LOCAL FIRE DEPARTMENT REGULATIONS.

22. WALL MOUNTED FIRE ALARM PULL STATIONS ARE TO BE LOCATED 46" A.F.F. AND

WITHIN 5' OF THE NEAREST ADJACENT EXIT DOOR FROM THE FLOOR OR

BUILDING.

23. WALL MOUNTED FIRE ALARM NOTIFICATION APPLIANCES, EITHER VISUAL, OR

COMBINATION AUDIO/VISUAL, SHALL BE LOCATED SUCH THAT THE ENTIRE LENS

OF THE VISUAL PORTION IS BETWEEN 80" AND 96" A.F.F. AUDIO ONLY APPLIANCES

SHALL BE LOCATED, NOT LESS THAN 90" A.F.F. TO TOP OF APPLIANCE, OR 6"

BELOW CEILING.

FIRE ALARM GENERAL NOTES

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

DUCT SMOKE DETECTOR

AREA SMOKE DETECTOR

DOOR RELEASE SMOKE DETECTOR

S O

U N

D G

E N

E R

A L

B U

IL

D

IN

G

A

LA

R

M

X

X

N O

T

IF

Y N

E C

E S

S A

R Y

S T

A

X

INPUT

OUTPUT

N O

T

IF

Y F

IR

E

D E

P A

R M

E N

T

IN

IT

IA

T

E S

U P

E R

V

IS

O R

Y S

IG

N

A L

T O

A

4- H

O U

R M

A N

N E

D P

O

IN

O

R

IM

M E

D

IA

T E

R E

S P

O N

S E

X

C

LO

S E

A S

S O

C

IA

T E

S M

O K

E

B

R R

IE

R

D O

O R

S O

N T

H

LO

O

R

X

MANUAL PULL STATION

ELEVATOR MACHINE ROOM HEAT DETECTOR

GENERATOR ROOM HEAT DETECTOR

X

X

X

X

X

X

X

X

X

ELEVATOR SMOKE DETECTOR X X X

X

C

LO

S E

D A

M P

E R

S O

N F

N

P

R O

X

IM

A T

E T

O D

E T

E C

T O

R

X

X

S H

U T

D O

W N

A U

R H

A N

D

LE

R V

E D

B Y

T H

E D

E T

E C

T O

R

X1

1. DO NOT PROVIDE DUCT DETECTORS IN DEDICATED (100%) EXHAUST FANS, THEY SHOULD CONTINUE TO RUN.

* THIS IS THE FULL VA ALARM MATRIX, SOME ELEMENTS WILL NOT BE USED IN THIS SPECIFIC BUILDING.

R E

C A

LL

E

LE

V

A T

O R

X

IN

IT

IA

T

E E

LE

V

A T

O R

S H

U

D

W

N A

N D

D

IS

C O

N N

E C

LE

V A

T O

R P

O W

E R

X

O P

E N

L O

C K

E D

E G

R E

D

O

R S

O N

F

LO

O R

O F

F

IR

IG

IN

X

X

X

X

FIRE ALARM MATRIX

D

IS

C O

N N

E C

T F

E U

L S

O U

R C

O M

C O

O K

IN

G

E Q

U

IP

M E

N T

SPRINKLER WATERFLOW / PRESSURE SWITCH

WATER CONTROL VALVE TAMPER

FIRE PUMP

HI/LOW PRESSURE DRY PIPE SPRINKLER SYS.

KITCHEN HOOD SUPPRESSION SYSTEM

GAS EXTINGUISHING SYSTEM

DRY-PIPE VALVE ROOM TEMPERATURE ALARM

DEDICATED FIRE WATER STORAGE TANK LOW LEVEL

DEDICATED FIRE WATER STORAGE TANK LOW TEMPERATURE

X X X X X

X

X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

FIRE ALARM

CONTROL PANEL

RM 1G23

BUILDING 204

LEVEL 1

NOTE: CONTRACTOR SHALL VERIFY ALL

NECESSARY DEVICE COUNTS

LEVEL 2

LEVEL 3

CAMPUS MAIN FACP

LOCATED IN BUILDING 58 &

LEVEL 4

LEVEL 5

NOTIFICATION APPLIANCES

BASEMENT ZONE 1 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 1 FIRE/SMOKE

BASEMENT

NOTIFICATION APPLIANCES

BASEMENT ZONE 2 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 2 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 3 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 3 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 4 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 4 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 5 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 5 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 6 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 6 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 7 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 7 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 8 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 8 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 9 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 9 FIRE/SMOKE

NOTIFICATION APPLIANCES

BASEMENT ZONE 10 FIRE/SMOKE

INITIATING DEVICES

BASEMENT ZONE 10 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 1 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 1 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 2 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 2 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 4 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 4 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 5 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 5 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 6 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 6 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 7 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 7 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 1 ZONE 3 FIRE/SMOKE

INITIATING DEVICES

LEVEL 1 ZONE 3 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 1 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 1 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 2 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 2 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 4 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 4 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 5 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 5 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 6 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 6 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 7 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 7 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 2 ZONE 3 FIRE/SMOKE

INITIATING DEVICES

LEVEL 2 ZONE 3 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 3 ZONE 1 FIRE/SMOKE

INITIATING DEVICES

LEVEL 3 ZONE 1 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 3 ZONE 2 FIRE/SMOKE

INITIATING DEVICES

LEVEL 3 ZONE 2 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 4 ZONE 1 FIRE/SMOKE

INITIATING DEVICES

LEVEL 4 ZONE 1 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 4 ZONE 2 FIRE/SMOKE

INITIATING DEVICES

LEVEL 4 ZONE 2 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 5 ZONE 1 FIRE/SMOKE

INITIATING DEVICES

LEVEL 5 ZONE 1 FIRE/SMOKE

NOTIFICATION APPLIANCES

LEVEL 5 ZONE 2 FIRE/SMOKE

INITIATING DEVICES

LEVEL 5 ZONE 2 FIRE/SMOKE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSDLO

BUILDING 163 - FIRE ALARM

GENERAL NOTES AND DETAILS

163-FA001

163 1 21

-1

-1

-F

A

/2

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: NTS

A12

BUILDING 163 - FIRE ALARM RISER DIAGRAM & CAMPUS RISER DIAGRAM

DANIEL L. OLIG

UP

UP

UP

UP

UP

DN

DN

DN

DN

DN

DN

DN

DN

UP

UP

DN

UP

UP

UP

UP

UP

DN

DN

DN

DN

DN

DN

DN

UP

UP

DN

F

S

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

BD108D

N/A

BD116

BD116A BD116B

BD108E

BS-7

BD100

BD108C

BS-6

BD115

BD108B

BD108A

CB23

BD103B

BD101

BD103

BD102

BD114

BD103C

BD113

BD103A

BD111

BD112BD1100BC102BC101 CB22BD105BD104 BD107BD106ABD108A BD109

BD111A

CB21

BB

126CBC103

BB130A

BB126B

BA108

BC104

BC105

BA108

BA108BBB127A BB127

BB130

BB126

BC127B

BB126A

BC106

CB10 BS-3

CB14 CB12

CB13

BC127

BB125

BB129B

BC128 BC108 BB129A

BA108B1

BB124

BC109

BB128

BB120

BA112ABC126 BC110A

BA121F

BA121GBC110 BA121J

BA112

BC125

BA119

BC109B BC109A

BC124

BB129 BB129E BB115B

BB129C

BA121C

BA108CBB117

NOT

LABELEDBC115

NO

TAG

NO

TAG

NO

TAG

BA121H

BC111

BA117 BA121A

NO

TAGBC107 BC107A

BB129FCB16 BB116

CB15

CB6

BC114A

BC114B

NO

TAG

NO

TAG CB5

BC112

BA115NO

TAG

BA118D

BB129GBC116D

BC123 BA110BC122A BA118B

BC113

BB112E BB112F BB112G BB115A BA107 BA120BC114

BC114C

BA113

BA111 BA118G

BA109BC116C BS-2

BC122A BC122

BB113B

BA118CBB112H

NO

TAG

NO

TAG

BB112D BB113D

BA118EBB

BC116BC119B

BA106BC119

BB

BA123

BC121

NO

TAG BA104

BA118F

BA105

BB110

BA114

BC116BBC119A BC116A CB3BB112

NO

TAG

BB112B CB2BB112ABC118 BA118H

BC119 BB113ABC120

BA103

BA229

BA228BA114A

BA225

CB8 CB7CB9 BA231

BS-5

CB4NO #

BB104 CB1

BC152 BB114A BB11BB11A1 BA221BB113BC153

BA227BA200B BA222 BA224

BS-1 BA223

BC150

BA220 BA225

BC151 BC154 BA200BB100A0

BB103

BA216 BA217 BA2180 BA225ABB105 BA213BB11A BA219

BA214

BB106

BA215 BA214A

BB105

BA214A

BB108

BB107C

BA226BB109 BA210

BB114

BA211 NO #N/A N/ABB107B BB101A BA212

BC150A

BB101

BA81

BA201 BA209

BA207BA208 N/A N/AXXXX BA203

BS-12

BA206

N/A

BA204

BA205

ALARM ZONE 1

ALARM ZONE 2

ALARM ZONE 3

ALARM ZONE 4

ALARM ZONE 5

ALARM ZONE 6

ALARM ZONE 7

ALARM ZONE 8

ALARM ZONE 9

ALARM ZONE 10

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

C

D

B A

1 2

3 4

*THIS OVERALL SHEET IS PROVIDED AND INTENDED FOR FIRE ALARM ZONE

CLARITY. REFERENCE THE ENLARGED AREA PLANS FOR DEVICE LAYOUT.

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSDLO

BUILDING 163 - FIRE ALARM PLAN -

BASEMENT - OVERALL

163-FA100

163 2 21

-1

-1

-F

A

/2

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1/16" = 1'-0"

A14

BUILDING 163 - FIRE ALARM PLAN - BASEMENT - OVERALL

N

DANIEL L. OLIG

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

UP

DN

DN

UP

UP

F

F

F

C

S C C

S C

S C

C

S C

S C

CC

C C C

C

C

S C

C C

C

S P

S P

C

C S C

S C

C

S C C

S C

C

C C

C

C

C S C S C

S C C S C

C S C C

C

C

C

C

S C C S C

S C

C

S C

S C C S C

C S C S C

C

S C C

S CC

C S C S C

C

S C

C

C

C

C S C

S C

S C C S C

C C

CC

C

S C S C S C C

C

C

C

CCS C

S C C C

C

F

VS VS

WF WF

DCL

D C

L

D C

L

DCL

D C

L

VS VS WF WF

DCL

S P

S

PS

P

S P

S P

S P

S

PS

P

S P

S P

S P

S P

S C

S

ID

S

ID

S

ID

S

ID

AR

S

AR

S

AR

AR

AR

VS VS

VS VS

VS

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

IT ROOMS

BB117

NOT

NOT

LABELED

PHARMACY

FLOOR

NO

TAG

PHARMACY

FLOOR

NO

TAG

PREP

BA121H

GEN. STO.

BA117

WOMEN

BA121A

PHARMACY

FLOOR

NO

TAG

ELECTRICAL

CLOSET

BB116

CORRIDOR

CB6

CORRIDOR

CB5

BA115

STERALIZATION

ROOM

NO

TAG

RESTROOM

BA118D

FIRE EQUIPMENT

HAC

BA110

MRI

BA118B

MEN

BA107

HOUSEKEEPING

CENTRAL

STORAGE

BA120

HOUSEKEEPING

EQUIPMENT RM

BA113SOILED LINEN

ROOM

BA111

CONTROL ROOM

BA118G

VCS SUPPORT

OPERATION

BA109 STAIR 2

BS-2

DRESSING ROOM

BA118C

MRI

BA118E

WOMEN

BA106

PIPE BASEMENT

ACCESS

CAN STORAGE

BA123

PHARMACY

FLOOR

NO

TAG

ELECTRICAL

ROOM

BA104

MRI

BA118F

CHIEF,

BA105

VCS STORAGE

BA114

CORRIDOR

CB3

ELEVATOR

LOBBY, SERVICE

CB2

MECHANICAL

ROOM

BA118H

IDF

BA103

MECHANICAL

ROOM

BA229

MENS ROOM

BA228

STORAGE

BA114A N & FS

BA225CORRIDOR

CB7

F.A.C.

BA231

CORRIDOR

CB4NO #

ELEVATOR

LOBBY,

PASSENGER

CB1

EMS

BA221

WOMEN ROOM

BA227NO NAME

BA200B

NUTRITION &

BA222

SITE

BA224STAIR 1

BS-1

FOOD

PROCUREMENT

BA223

OFFICE SUPPLIES

BA220

N & FS

BA225

DISHWASHING

BA200

CANTEEN

DINING/VENDING

BB100A

DINING ROOM

BB103

DIETITIAN

BA216

CHIEF, FOOD

PRODUCTION

BA217

DIET

BA218

STORAGE

BA225A RECEIVING

BA213FOOD SERVICE

BA219

CENTRAL TRAY

BA214

COOK FORMAN

BA215

STORAGE

BA214A

NO NAME

BA214A

FOOD

BA226 RECEIVING

BA210

INGREDIENT

CONTROL

BA211

MECHANICAL

ROOM

NO #

COOLER

N/A

BOX#4

N/A

VESTIBULE

BA212

DRY STORAGE

BA81

EMS

BA201

PRODUCE

BA209 MEAT

BA207

FOOD

PRODUCTION

BA208 BOX#1

N/A

BOX#3

N/A

NO NAME

XXXX

ADVANCED FOOD

BA203

STAIR 12

BS-12

INGREDIENT

CONTROL

BA206

BOX#2

N/A

CONVENTIONAL

BA204

POT & PAN

BA205

ALARM ZONE 8

ALARM ZONE 9

ALARM ZONE 10

P-1

P-2

S-3 S-4

TAMPER SWITCHES LOCATED

AT SUB-BASEMENT LEVEL

TAMPER SWITCH AT

SUB-BASEMENT LEVEL

BY STAIR 2

C

D

B

A

1 2

3 4

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSChecker

BUILDING 163 - FIRE ALARM PLAN -

BASEMENT - AREA AB

163-FA100-AB

163 3 21

-1

-1

-F

A -A

B

/0

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1/8" = 1'-0"

A16

BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA AB

N

DANIEL L. OLIG

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

UP

UP

DN

DN

DN

DN

DN

DN

DN

DN

F

F

C

S C

C

C

C

S C

C

S P

C

C C

S C

C

S C

S C

C S C

S C C

C

S C C

S C

C C C

S C C C

CC

C

C S C

CS C

C

S C

C

S C

C

S C

C

S C

S C

C

S C

VS

VSWF

D C

L

VS VS VS

VSVSVS

VS WF

DCL

S P

S P

VS

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

AR

S

AR

S

AIO

AIO

AR

AR

AR

VS

S

ID

S

ID

S

ID

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

GAS STORAGE

BD116

ELECTRICAL

ROOM

BD116A

EMERGANCY

GEN.

BD116B

TRAINING

BD108E

STAIR 7

BS-7

LMS RECEIVING

BD115

CORRIDOR

CB23

SOILED LINEN

BD114

IDF

BD113

MECHANICAL

ROOM

BD111

TRASH ROOM

BD112

CORRIDOR

CB22

A5 OFFICE

BD111A

CLOSET

BB

126C

ASST CHIEF SPS

BB126B

CONTROL ROOM

BA108

TRANSFORMER

ROOM

BA108

PIPE BASEMENT

ACCESS

MECHANICAL

ROOM

BA108B

SPS ADMIN

BB126

CHIEF SPS

BB126A

CORRIDOR

CB10

STAIR 3

BS-3

FIRE EQUIPMENT

KINESIOTHERAPY

OFFICE

BB125 ELECTRICAL

ROOM

BA108B1

KINESIOTHERAPY

BB124 WAITING/RECEPTION

BB120 STORAGE

BA112A

COLD

BA121F

AUTOPSY

BA121GCROSS

BA121J

CANTEEN RETAIL

BA112

NOT

BA119

MEN

BA121C

MORGUE

BA108C

IT ROOMS

BB117

NOT

NOT

LABELED

PHARMACY

FLOOR

NO

TAG

PHARMACY

FLOOR

NO

TAG

PREP

BA121H

GEN. STO.

BA117

WOMEN

BA121A

PHARMACY

FLOOR

NO

TAG

ELECTRICAL

CLOSET

BB116

CORRIDOR

CB6

CORRIDOR

CB5

STERALIZATION

ROOM

NO

TAG

ALARM ZONE 3

ALARM ZONE 5

S-7

ADDRESSABLE IN/OUT MONITOR

FOR POWER AND RUNNING

STATES OF FIRE PUMP

TAMPER SWITCH IN STAIR 7 AT

SUB-BASEMENT LEVEL

*IN-DUCT SMOKE DETCTORS - THREE AT

RETAIL STORE BALL 2 ON CEILING,

THREE AT PATRIOT CAFE ON CEILING

C

D

B

A

1 2

3 4

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSChecker

BUILDING 163 - FIRE ALARM PLAN -

BASEMENT - AREA ABD

163-FA100-ABD

163 4 21

-1

-1

-F

A -A

B D

/0

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1/8" = 1'-0"

A16

BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA ABD

N

FIRE PUMP LOCATION - PROVIDE

MONITORING OF POWER OFF, PHASE

REVERSAL, AND PUMP RUNNING AS

REQUIRED BY NFPA 20

DANIEL L. OLIG

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

UP

F

C S C

C S C

S C

C

S C

C

CS C

C

S C

CS C

CS CS CC

S C

S C

S C

C

C

S C

C

C C C

C S

C

S C

S P

H F

S P

VS

VS

VS

VS WF

DCL

D C

L S

P

S P

S P

S P

C

C

S C

S C

C

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

H F

AR

S

AR

S

AR

S

AR

S

AR

S

AR

S

AR

S

AR

S

AR AR

AR

VS

VS

S

ID

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

SUPPLY ROOM

BB129C

PHYSIATRY

BC115

PHARMACY

FLOOR

NO

TAG

PHARMACY

FLOOR

NO

TAG

STAFF

PHYSIATRIST

BC111 CHIROPRACTIC

OFFICE

BC107

CHIROPRACTIC

EXAM ROOM

BC107A

DRESSING ROOM

BB129F

CORRIDOR

CB16

CORRIDOR

CB15

SUPERVISOR

OFFICE PHYSICAL

THERAPY

BC114A

SUPERVISOR

OFFICE

KINESIOTHERAPY

THERAPY

BC114B

OFFICE

NO

TAG

OFFICE

NO

TAG

EXAM ROOM

BC112

STERALIZATION

ROOM

NO

TAG

PUMP ROOM

BB129G

SLP LAB &

TREATMENT RM.

BC116D

ELECTRICAL

ROOM

BC123EXAM ROOM

BC122A ADPAC

BC113

ASSISTANT CHIEF

PHARMACY

SERVICE

BB112E

PROGRAM

SPECIALIST

BB112F

CHIEF

PHARMACY

SERVICE

BB112G

CONT. SUB.

VAULT

BB115A

CLINICAL

COORDINATOR

BC114

SUPERVISOR

OFFICE

OCCUPATIONAL

THERAPY

BC114C

COMPUTER

ROOM

BC116CEXAM ROOM

BC122A

STAFF

PHYSIATRIST

BC122 OFFICE

BB113B

OFFICE

CBOC

BB112H OFFICE

NO

TAG

RESTROOM

NO

TAG

CLINICAL

COORDINATOR

BB112D

CONFERENCE

ROOM

BB113D

PHARMACY

SERVICE

BB

SPEECH &

LANGUAGE

PATHOLOGY

BC116

EXAM ROOM

BC119B

OFFICE

BC119

COORIDOR

BBPSYCHOLOGIST

BC121

PHARMACY

FLOOR

NO

TAG

PHARMACY

SERVICE

BB110

SPEECH

PATHOLOGIST

BC116B

CHIEF PM & RS

BC119A

SPEECH

PATHOLOGIST

BC116A

PHARMACY

SERVICE

BB112

BREAKROOM

NO

TAG

ADMIN OFFICE

BB112B

CLERKS

BB112A

STORAGE

BC118

SECRETARY PM &

RS

BC119

ADPAC

BB113A

SLP SUPERVISOR

BC120

CORRIDOR

CB8

CORRIDOR

CB9

STAIR 5

BS-5

STAFF ONLY

BB104

STORAGE

BC152

RADIOACTIVE

WASTE STORAGE

BB114A

TELEPHONE

BB11

NO TAG

BB11A1

MECH ROOM

BB113

NOT LABELED

BC153

MECHANICAL

ROOM

BC150

ELEVATOR

MACHINE ROOM

BC151

ELECTRICAL

ROOM

BC154

CORRIDOR

0 DINING ROOM

BB103

CORRIDOR

STORAGE

BB105NO TAG

BB11A

EMS

BB106

STORAGE

BB105

ELECTRICAL

BB108

WALK-IN 1

BB107C

CANTEEN

BB109

MECH ROOM

BB114

WALK-IN 2

BB107B

STORAGE

BB101A

MECHANICAL

ROOM

BC150A

KITCHEN

BB101

ALARM ZONE 6

ALARM ZONE 7

ALARM ZONE 8P-12 P-11

FA05

*TWO DUCT DETECTORS AT AHU-1,

ONE DETECTOR ON CEILING

TAMPER SWITCHES IN

STAIR 5 AT SUB-

BASEMENT LEVEL

C

D

B

A

1 2

3 4

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSChecker

BUILDING 163 - FIRE ALARM PLAN -

BASEMENT - AREA BC

163-FA100-BC

163 5 21

-1

-1

-F

A -B

C

/0

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1/8" = 1'-0"

A16

BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA C

KEYNOTE LEGEND

FA05 HEAT DETECTOR IN ELEVATOR MACHINE ROOM TO REMOVE POWER PRIOR TO

DISCHARGE FROM SPRINKLERS.

N

DANIEL L. OLIG

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

UP

F

F

C

S C

S C

S C

C

C

C S C

S C C

S C

C

S P

H F

S P

C

C S C S C

C

S C

C

C S C

C S C S C

C

S C

S C

C S C S C C

C

C

C S C C CC

C

S C

S C S C S C

CS CS C

S CC

S C C

C S C

C S C

S C

C C

S C

C

C

C

C

VS

DCL DCL

D C

L

S P

S P

S P

S P

D C

L

S P

S P

DCL

S P

S P

S P

S P

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

S

ID

H F

H F

H F

AR

S

AR

S

AR

S

AR

S

AR

AR

AR

AR

VS

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

HOUSEKEEPING

BD108D

BACK OF

STERILIZER

N/A

LMS STORAGE

BD100

SPD

BD108C

STAIR 6

BS-6

CART LIFT

BD108B

LMS

DISTRIBUTION

BD108A

ELEVATOR

LOBBY

AUTOMATIC CART

WASHER

BD103B

SPD MALE

DECON/

BD101

SPD

DECONTAMINATION

BD103

SPD FEMALE

DECON/

BD102

SUPPLY

BD103C

HOUSEKEEPING

BD103A

ELEC. ROOM

BD110

CORRIDOR

ELEVATOR

EQUIPMENT

BC102

MECHANICAL

ROOM

BC101

SPS ECUCATOR

BD105

CART LIFT

MECHANICAL RM

BD104

COMPUTER

BD107

CHIEF,

BD106A

MSD&E SECTION

BD108A

ELE.

BD109

CORRIDOR

CB21

COMMUNICATIONS

ROOM

BC103

RESEARCH

STORAGE

BB130A ASST CHIEF SPS

BB126BLMS EQUIPMENT

STORAGE

BC104 HAC

BC105

PT OFFICE

BB127A

PHYSICAL

THERAPY

BB127

RESEARCH

BB130

RESTROOM, MEN

BC127B

CHIEF SPS

BB126A

ELECTRICAL

ROOM

BC106

CORRIDOR

CB14 CORRIDOR

CB12

CORRIDOR

CB13 FIRE EQUIPMENT

LOCKER ROOM,

MEN

BC127

KINESIOTHERAPY

OFFICE

BB125

WOMEN SHOWER

BB129B

STAFF

PHYSIATRIST

BC128

EXAM ROOM

BC108

MEN SHOWER

BB129A

KINESIOTHERAPY

BB124

OCCUPATIONAL

THERAPY

BC109

KINESIOTHERAPY

BB128

OFFICE

BC126

EXAM ROOM

BC110A PHYSIATRIC

CLINIC

BC110

EXAM ROOM

BC125

OFFICE

BC109B

OFFICE

BC109A

LOCKER ROOM,

WOMEN

BC124

THERAPEUTIC

POOL

BB129 LINEN ROOM

BB129E

HOUSEKEEPING

BB115B

SUPPLY ROOM

BB129C

PHYSIATRY

BC115

PHARMACY

FLOOR

NO

TAG

PHARMACY

FLOOR

NO

TAG

STAFF

PHYSIATRIST

BC111 CHIROPRACTIC

OFFICE

BC107

CHIROPRACTIC

EXAM ROOM

BC107A

DRESSING ROOM

BB129F

CORRIDOR

CB16

CORRIDOR

CB15

SUPERVISOR

OFFICE PHYSICAL

THERAPY

BC114A

SUPERVISOR

OFFICE

KINESIOTHERAPY

THERAPY

BC114B

OFFICE

NO

TAG

OFFICE

NO

TAG

EXAM ROOM

BC112

STERALIZATION

ROOM

NO

TAG

ALARM ZONE 1

ALARM ZONE 2

ALARM ZONE 4

S-7

P-5

P-6

FA05

*TWO DUCT DETECTORS

LOCATED AT AHU-1 AND

AHU-2

TAMPER SWITCH IN STAIR 6 AT

SUB-BASEMENT LEVEL

C

D

B A

1 2

3 4

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSChecker

BUILDING 163 - FIRE ALARM PLAN -

BASEMENT - AREA BCD

163-FA100-BCD

163 6 21

-1

-1

-F

A -B

C D

/0

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1/8" = 1'-0"

A16

BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BCD

KEYNOTE LEGEND

FA05 HEAT DETECTOR IN ELEVATOR MACHINE ROOM TO REMOVE POWER PRIOR TO

DISCHARGE FROM SPRINKLERS.

N

DANIEL L. OLIG

DN

UP

UP

UP

UP

UP

UP

UP

UP

DN

UP

DN

DN

DN

DN

DN

DN

DN

DN

F

S

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

ALARM ZONE 1

ALARM ZONE 2

ALARM ZONE 3

ALARM ZONE 1

ALARM ZONE 5

ALARM ZONE 4

ALARM ZONE 6

ALARM ZONE 7

1D108C 1D124A 1D101A 3

1D124 1D108A

1D105 1D108 1D101B 1D101C1D101 1D123

1D1091D100

1D1061D103

1D122

1D121

1C41 1S6

1D

1K

1D1201D110 1D122A1D1191D107

1D111

1D104A

1D102 1D114 1D118 6

1D1271D112 1D116

1C29

1D1171D104B

1D1131D104C 1D115

1C30 1A126A 1A118 1A121A

1A1291A126 1A130A1B172 1A1281B150B 1A1231A117 1A123A1C36C 1A1198

1B1651C31 1B154A 1B1711B164

1A121 1B160 1B164B 1A1A115A1C32

1B150C

1B150

1A1301C33 1A12711 1A1151B154D 1B1691B1661B164A

1A124B 1A124A1C36 1A132

1A11412 1A1201B163 1A1311B158 1B150A1B155 1A1221A1131B156 1A1341B1681B167 1B152 1B151

1A112B 1A112D 1A120A 1A148 131A120B14 1A136A 1A136B 1A135

1A112C 1A147

1A112A

1A1361A109A 1B153

1B162C 16 1C35 1B149 1A137

1A152A1C02E 171C18 1A111 1A1461B1621B162A1C16

1A144A 1A111A

1A138 1C02D

1A142A 1A152D1A152C1C411C151C13 1A1411A144

1C14 1B172B 1A10918 1A110

1A1521B1721B148 1B172A 1B162B1B173 1A1421A110B 1A1391C38 1B147 1C1119 1A1501A110A

1C40

1C12

20 21 1A133

1C39

1C02C 1A1431A151

1B23 1A145A1B22 1B24 1B2301C10 1B2051C09 1A1081B231 1B2031B201 1A140 221B204

1A1451C02 1B251B21

1C01 1B229 1B2061C07 1C08 1B26 C1-28

1A1051B20 1A155C1B228 1A103 1A1541B227 1A145CC1-271B27

1B2021B19A 1B173J1B28 1B207

241B209 C1-29 251B226C1-18A 1A155B1B29 1A1071B225 1B210

1B30

1A145G

1A104C1-52 1A145B

1B19 1C05 1C031C04 26 1B208 1A106 1A145J

1A1551A170A1B31 1S5 C1-19D

1B32 1B224 1B200C1-32 1A155A

1A179 1A170 1A178

1B175 1A169 1A169A1B34 1A155D1B2231B33 1A1561A182

1B21127 1B176A

1A18528 1A177C1-20 1B351B41 1A172 1A1741B222

1B1761B44 1B221

1A176 1A1871B178 29 1A157

1B361C153

1B18 30 C1-21 1B2151B220 C1-33

1B2191B37 1B77B1C154 1B43 1B40

1A101 1A158A1C168 1A181 1A1831C176 1B38 C1-311C1551C170 1B79A1B391B42 1A1711B17 1A184

1A1861B18A C1-22C1-51 1B2121C173 1A1581A1801A1681C1721C167 1C178 1B180A1B02 1A1731B218

1A1671C156 1B2171B79 1B216 1B214 1B2131C157 1B81B1B81A1B16 1B801C169 1C177 1A164 1A163

1A1611C166

1A159B32 33 1A166A 1A159C1B

1A166 1A160B1A164B1C165B

1B15 1B13 1B101B12 1B09 1B041B061B08 1B051B071C163 1C162 1E1481C1591C160 1A164D 1A1601A164A 1A1621A165A 1A1591C161 1A164E 1A165 1A164F 1A159A

1A164C

1B3421B332

1B336 1B3381B337 1B3391B334 1B3351B330 1B331 1B3411B340

1B333

1B011B343

1B35935

1B356 1B3721B366 1B3671B3651B364 1B369 1B3711B3701B3681B363

1B302

1B353 1B3501B351 1B349 1B3471B3481B352 1B3461B355 1B345 1B344

1B373

1B303

1B316 1B3151B317 1B314 1B311 1B3101B313 1B312 1B309 1B3061B308 1B307 1B305

1B304

1D104

1B174

1B170

1A145D

1A145E

1E1001E101

1E102

1E103

1E104 1E105

1E106

1E107

1E108 1E109 1E110 1E111 1E112

1E113

1E114 1E115 1E116 1E117 1E118

1E119

1E120

1E121

1E122

1E123

1E1241E125

1E126

1E1301E131

1E132

1E133

1E134 1E135

1E136 1E137 1E141 1E142

1E143 1E144

1E145

1E146

1E1471E149

1E150 1E1511E1521E153

1E156

1E157 1E158

1E1591E160

1E161

1E1621E1631E164 1E1651E1671E168

1E169

1E170

1E171

1E172

1E173

1E174

1E166

1E157A

C1-52A

1D108E

1D108F

1D108G

1D108H

1B154

C1-28A

1D122B

1D122C

1C06

1C11A

1C02A

1C02B

1C27 1C27A

1C27B

1C21A

1C21

1C24

1C22

1C22A 1C23A

1C23

1C28

1C26

1C25

1C27C

C1-21

1C27D

1A160A

1C02G 1C02H

1B354

1A175

1A155E

1D108B

FIRE ALARM SYMBOLS

DEVICES

WEATHERPROOF SPEAKER/STROBE

SYMBOL DESCRIPTION

DETECTORS

MANUAL PULL STATION

SPEAKER ONLY CEILING MOUNTED

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

SPEAKER ONLY WALL MOUNTED

STROBE ONLY CEILING MOUNTED

STROBE ONLY WALL MOUNTED

MNS SPEAKER/STROBE CEILING MOUNTED

GAS DETECTOR - CARBON MONOXIDE

HEAT DETECTOR - FIXED TEMPERATURE ONLY

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

SWITCHES

FLOW DETECTOR/SWITCH

TEMPERATURE SUPERVISORY SWITCH

VALVE SUPERVISORY SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

PANELS

LINE TYPES

SMOKE/ALARM ZONE BOUNDARY LINES

DOOR HOLDER

DOOR CLOSER

W

ADDRESSABLE RELAY

ADDRESSABLE RELAY - FIRE SHUTTER

ADDRESSABLE RELAY - FAN SHUTDOWN

REMOTE TEST SWITCH

ADDRESSABLE INPUT/OUTPUT MODULE

C

D

B A

1 2

5 6

3 4

E

CODE DATA

OCCUPANCY HEALTHCARE

SPRINKLERS FULLY SPRINKLERED

NOTIFICATION SPEAKERS, STROBES AND COMBINATION SPEAKER-STROBES IN

NORMALL OCCUPIED AREAS

DETECTION MANUAL PULL-STATIONS, SPRINKLERS, SMOKE DETECTOR AT

FACP, CO DETECTOR AT FUEL FIRED EQUIPMENT

FIRE ALARM

ZONING

FIRE ALARM SYSTEM ZONING TO MATCH EXISTING SMOKE

ZONES

*THIS OVERALL SHEET IS PROVIDED AND INTENDED FOR FIRE ALARM ZONE

CLARITY. REFERENCE THE ENLARGED AREA PLANS FOR DEVICE LAYOUT.

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

FIRE PROTECTION:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez

ARCHITECT:

CB DESIGN GROUP

421 KING ST., SUITE 301

ALEXANDRIA, VA 22314

POC: WES BRIDGES

703.772.4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

FULLY

SPRINKLERED Drawing of

ADDENDUM 1 02/03/2023

11/09/2021

100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX 76504

617-19-102

CSSDLO

BUILDING 163 - FIRE ALARM PLAN -

LEVEL 1 - OVERALL

163-FA101

163 7 21

-1

-1

-F

A

/2

/2

.p d f

TEMPLE VA MEDICAL CENTER - FIRE

ALARM CAMPUS UPGRADE

SCALE: 1" = 20'-0"

A16

BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - OVERALL

N

DANIEL L. OLIG

S C

M

C

CO

H F

S

ID

S P

WF

TSS

VS

FAA

FACP

FATC

DH

DCL

AR

AR

FS

AR

S

RTS

AIO

UP

UP

UP

DN

DN

DN

F

F

S C C C

C

S C

C S C

S C C

C

S C

C

CS C

C

S C S C C

C

C

C

C

C

C

C

C

S C

C

C

CS CS CS C

CS C

C

C

C

C

S C

C

S C

C

C

CS CCC

S C

C

C

C

C

S C

C

C

S C

C

C

C

C

C

C S C

C

C

C

S P

S P

F

C VS

VS VS

WF

WF WF

D C

L

DCL

S P

S P

S P

S P

DCL

S P

S…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .