VA TEM FA ADDENDUM 1 Drawings Phase 2 signed.pdf
PDF 19 MB Posted
- Attached to
- Y1DA--674-22-801 Upgrade Fire Alarm System Phase 2 Federal contract opportunity
- Solicitation number
- 36C25722B0021
About this file
This document provides details for a federal contract solicitation to upgrade the fire alarm system at the Temple VA medical center in Temple, Texas. The solicitation number is 36C25722B0021 and concerns project number 674-22-801 to upgrade the fire alarm system in Phase 2. The purpose of the project is to upgrade the fire alarm system in Phase 2 at the Temple VA located at 1901 Veterans Memorial Drive in Temple, Texas. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Above finished floor AFF Acoustic ACST Acoustic Panel Ceiling APC Addendum ADD Alternate ALT Aluminum AL Angle L Approximate APPROX Architecture, architectural ARCH Asbestos ASB Asphalt ASPH Assistant ASST Association ASSN Automatic AUTO Average AVG Base plate BP Basement BSMT Beam BM Bearing BRG Bedroom BR Benchmark BM Board BD Boiler BLR Bottom BOT Brick BRK Building line BL Building BLDG Built-up-roof BUR Cabinet CAB Carpet CPT Catalog CAT Ceiling height CH Ceiling CLG Center CTR Centerline CL Ceramic Tile CT Ceramic CER Chalkboard CB Clear CLR Closet CLO Coated CTD Cold rolled CR Column COL Company CO Composition COMP Concrete Masonry Unit CMU Concrete CONC Construction joint CJ Construction CONSTR "Continue, Continuous" CONT Corridor CORR Countersink CSK Cubic CU Curve(d) CRV Dampproofing DP Degree DEG Department(al) DEPT Detail DET Diagonal DIAG Diameter DIA Dimension DIM Dishwasher DW Dispenser DISP Door DR Double DBL Double-hung DH Down DN Downspout DS Drain DR Drawing DWG Each EA East E Electric Water Cooler EWC "Electric, electrical" ELEC Elevation EL Elevator ELEV Engineer ENGR Entrance ENTR Equal EQ Equipment EQUIP Exhaust EXH Existing EXIST Expansion joint EXP JT Exposed EXP Exterior EXT Fabricate FAB Face of Stud F. OF S.
Fan Coil Unit FCU Fiberglass-reinforced plastics FRP Finish FIN Finished Floor FF Fire Extinguisher FE Fire Extinguisher & Cabinet FEC Fire Retardant Treated FRT Fireproof FPRF Fixture FXTR Flange FLG Flashing FL Floor FL Floor drain FD Flooring FLG Fluorescent FLUOR
Footing FTG Foundation FDN Furnish(ed), furniture FURN Furring FURR Gage (gauge) GA Galvanize(d) GALV Galvanized Iron GALVI Glazed Wall Tile GWT Grab Bar GB Grade GR Gravel GVL Gypsum Wallboard GWB Gypsum GYP Handicapped HC Hardware HDW Heating ventilating and HVAC air conditioning Height HGT High Point HPT High Performance HP High Performance Coating HPC Hollow Metal HM Horizontal HORIZ Include(d), inclusive INCL Incorporated INC Information INFO Inside diameter ID Install(ed), installation INSTL Insulation INSUL Interior INT Janitor JAN Joint JT Joist J, JST Junction box JB Knock down KD Laboratory LAB Lavatory LAV Left Hand LH Left L Length LG Level LVL Light LT Machine MACH Maintenance MAINT Manager MGR Manual MNL Manufacturing MFG Markerboard MB Masonry opening MO Masonry MSNRY Master bedroom MBR Material MATL Maximum MAX Mechanical MECH Membrane MEMB Men M Metal MET, MTL Mezzanine MEZZ Minimum MIN Mirror MIR Miscellaneous MISC Mounted MTD Mounting MTG Necessary NEC Noise-reduction coefficient NRC Nominal NOM Non Combustible NC, NONCOM North N Not in Contract NIC Not to scale NTS Not available NA Number NO Office OFF On center OC Opening OPNG Opposite OPP Outside diameter OD Overall OA Overhead OVHD Page P Painted PTD Pair PR Panel PNL Partition PTN Percent PCT Perforate(d) PERF Permanent PERM Perpendicular PERP Piece PC Plastic Laminate PLAM Plastic Laminate PLAS.LAM Plate PL Plumbing PLMB Plywood PLYWD Point PT Polyvinyl chloride PVC Precast PRCST Prefabricated PREFAB Preliminary PRELIM Preparation, prepare PREP Program PRGM Projection Screen PS
Project PROJ Property PROP Public Address PA Quality control QC Quality QUAL Quantity QTY Quarry Tile QT Radius RAD Rain Leader RL Received RCVD Receptacle RCPT Receptionist RECPT Recess(ed) REC Refer, reference REF Refrigerate, refrigerator REFR Reinforce REINF Reinforced concrete RC Remove RMV Repair RPR Required REQD Revise, revision REV Right hand RH Road RD Roof Drain RD Roof RF Roofing RFG Room RM Rubber tile floor RTF Rubber RBR Schedule SCHED Schematic SCHEM Section SECT Service SVCE "Sheet, sheeting" SHT Shower SH Siding SDG Similar SIM Slope SL Sound-transmission class STC South S Speaker SPKR Specification SPEC Sprinkler SPR Square SQ Stainless steel SS Standard STD Standpipe SP Steel STL Storage STOR Structural Glazed Facing Tile SGFT Structural, structure STRUCT Substitute SUBST Surface SURF Suspend(ed) SUSP Switch SW Symmetrical SYM System SYS Tackboard TB Tackstrip TS Telephone TEL Television TV Temporary TEMP Terrazzo TER Thick THK Through THRU Toilet T Tongue and groove T&G Top and bottom T&B Top chord TC Top of Masonry Parapet TMP Top of Bearing TOFB Top of Steel T.O.S.
Topping TOPG Total TOT Transformer XFMR Transom TR Transparent TRANS Tread TRD Threshold THRESH Typical TYP Underground UG Underwriters Laboratories UL Unfinished UNF Unit Ventilator UV Unless Otherwise Noted UON Urinal UR US Gypsum Company USG Vertical VERT Vestibule VEST, V Vinyl Reducing Strip VRS Vinyl Composite Tile VCT Vinyl asbestos tile VAT Wardrobe WARD Water closet WC Waterproof WP Weight WT Welded WLD Welded Wire Mesh WWM With W/ Without W/O Women W Wood WD Wrought Iron WI
A100A
SIM
A101
SIM
DEPT.
ADD
GRID LINES
SECTIONS
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAILS IN PLAN/SECTION
ROOM NUMBER
DOOR NO. ON PLAN
H.M. FRAME
NO. ON PLAN
REVISION: TYPE =
A.S.I/P.R./C.C.D./ADD.
CASEWORK
(FURNISHING PLANS ONLY)
ALUM. FRAME/WINDOW
TYPE
WALL TYPE
# # INTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
A3
ROOM NAME
B101a
BOUNDARY INDICATES
BUILDINGS INCLUDED IN
THIS PACKAGE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
Drawing of
11/09/2021
100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
674-22-801
CSSDLO
COVER SHEET
GI001
-2
-8
G I0
/0
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
Fire Alarm Campus Upgrade Phase II
100% CD Submission 674-22-801
Temple VA Medical Center 1901 Veterans Memorial Drive
Temple, TX 76504
204-E101 ELECTRICAL PLAN – LEVEL 1 X X
202-E101 ELECTRICAL PLAN – LEVEL 1 X X
163-E101 ELECTRICAL PLAN – LEVEL 1 X X
ELECTRICAL:
204-FA106-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA K X X
204-FA106-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA J X X
204-FA106-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 - AREA G X X
204-FA106 BUILDING 204 - FIRE ALARM PLAN - LEVEL 6 X X
204-FA105-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA K X X
204-FA105-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA J X X
204-FA105-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 - AREA G X X
204-FA105 BUILDING 204 - FIRE ALARM PLAN - LEVEL 5 X X
204-FA104-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA K X X
204-FA104-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA J X X
204-FA104-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 - AREA G X X
204-FA104 BUILDING 204 - FIRE ALARM PLAN - LEVEL 4 X X
204-FA103-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA K X X
204-FA103-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA J X X
204-FA103-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 - AREA G X X
204-FA103 BUILDING 204 - FIRE ALARM PLAN - LEVEL 3 X X
204-FA102-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA K X X
204-FA102-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA J X X
204-FA102-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 - AREA G X X
204-FA102 BUILDING 204 - FIRE ALARM PLAN - LEVEL 2 X X
204-FA101-K BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA K X X
204-FA101-J BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA J X X
204-FA101-G BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 - AREA G X X
204-FA101 BUILDING 204 - FIRE ALARM PLAN - LEVEL 1 X X
204-FA100-G BUILDING 204 - FIRE ALARM PLAN - BASEMENT LEVEL - AREA G X X
204-FA100 BUILDING 204 - FIRE ALARM PLAN - BASEMENT LEVEL X X
204-FA001 BUILDING 204 - FIRE ALARM GENERAL NOTES AND DETAILS X
202-FA102-D BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA D X X
202-FA102-C BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA C X X
202-FA102-B BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA B X X
202-FA102-AF BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 - AREA AF X X
202-FA102 BUILDING 202 - FIRE ALARM PLAN - LEVEL 2 X X
202-FA101-EW BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA EW X X
202-FA101-EE BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA EE X X
202-FA101-D BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA D X X
202-FA101-C BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA C X X
202-FA101-B BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA B X X
202-FA101-AF BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 - AREA AF X X
202-FA101 BUILDING 202 - FIRE ALARM PLAN - LEVEL 1 X X
202-FA001 BUILDING 202 - FIRE ALARM GENERAL NOTES AND DETAILS X
163-FA105 BUILDING 163 - FIRE ALARM PLAN - LEVEL 5 - OVERALL X X
163-FA104 BUILDING 163 - FIRE ALARM PLAN - LEVEL 4 - OVERALL X X
163-FA103 BUILDING 163 - FIRE ALARM PLAN - LEVEL 3 - OVERALL X X
163-FA102-D BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA D X X
163-FA102-CM BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA CM X X
163-FA102-C BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA C X X
163-FA102-AB BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - AREA AB X X
163-FA102 BUILDING 163 - FIRE ALARM PLAN - LEVEL 2 - OVERALL X X
163-FA101-BCD BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA BCD X
163-FA101-BC BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA BC X
163-FA101-ABD BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA ABD X
163-FA101-AB BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - AREA AB X
163-FA101 BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - OVERALL X X
163-FA100-BCD BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BCD X X
163-FA100-BC BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BC X X
163-FA100-ABD BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA ABD X X
163-FA100-AB BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA AB X X
163-FA100 BUILDING 163 - FIRE ALARM PLAN - BASEMENT - OVERALL X X
163-FA001 BUILDING 163 - FIRE ALARM GENERAL NOTES AND DETAILS X
FIRE PROTECTION:
GI003 PENETRATION DETAILS X X
GI002 SITE ORIENTATION PLAN X
GI001 COVER SHEET X X X
GENERAL:
SHEET NUMBER SHEET NAME 35% 65% 100% 100% FINAL
DANIEL L. OLIG
144883
03FEB2023
CAMPUS MAIN FIRE
ALARM CONTROL PANEL
IN BUILDING 58 & 204
FACP RM 102
BUILDING 53
FACP RM 101
BUILDING 55
FACP
BUILDING 46
FACP RM A23
BUILDING 171
FACP RM 10
BUILDING 158
FACP RM E133
BUILDING 147
FACP RM 102
BUILDING 222
FACP RM C1-29
BUILDING 202
FACP W. WALL
BUILDING 62
FACP
BUILDING 58
FACP RM 1A-102 / RM 1C-102
BUILDING 221
FACP CORR. 115
BUILDING 220
FACP W. WALL
BUILDING 206
FACP RM 1R40
BUILDING 205
FACP RM 1G23
BUILDING 204
FACP CORR. 102
BUILDING 64
FACP RM C1-4
BUILDING 99
FACP CORR. C1
BUILDING 146
BUILDING 201
NOTE: BUILDINGS 200 AND 201 ARE NOT INCLUDED IN THE ALARM REPLACEMENT
SCOPE FOR THIS PROJECT. THESE BUILDINGS ARE MONITORED BY THE FIRE ALARM
CONTROL PANEL IN BUILDING 204. THESE BUILDINGS WILL NEED TO BE MONITORED
BY THE NEW ALARM CONTROL PANEL AND MAIN CONTROL UNITS.
FACP
BUILDING 47
BUILDING 200
FACP IN CORR.
B/W 46 & 47
FACP
BUILDING 44
FACP
BUILDING 45
BUILDINGS 208,
209, 210, 211, 212, 213, 214, 215, 216
FACP IN BLDG 204 RM 1G23
BUILDING 163
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
674-22-801
CSSDLO
SITE ORIENTATION PLAN
GI002
-2
-8
G I0
/2
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
204 Teague Hospital
202 Domicilliary, WTRC, Mental Health Clinic
163 Teague Tower Hosp. Clinics, Surg, Lab, Rad, cafeteria, gift store.
Building # Building Name
SCALE: NTS
A15
VA TEMPLE - SITE ORIENTATION PLAN
SCALE: NTS
C5
VA TEMPLE - CAMPUS FIRE ALARM RISER DIAGRAM
DANIEL L. OLIG
FIRE RESISTANT RATED WALL CONSTRUCTION
THROUGH PENETRATION FIRESTOPPING SYSTEM
PROVIDE SYSTEM IN ACCORDANCE WITH FIRESTOPPING SCHEDULE
WALL PENETRATION - SEE DRAWINGS
SLAB PENETRATION - SEE DRAWINGS
THROUGH PENETRATION FIRESTOPPING SYSTEM
PROVIDE SYSTEM IN ACCORDANCE WITH
FIRESTOPPING SCHEDULE
FIRE RESISTANCE RATED FLOOR CONSTRUCTION
FLOOR PIPE PENETRATION
UL No: F-L-1020
JOINT SEALANT APPLIED
WITHIN OPENING
METAL PIPE
CONCRETE OVER COMPOSITE
STEEL DECK
MINERAL WOOL INSULATION
JOINT SEALANT
JOINT SEALANT
MINERAL WOOL
INSULATION
METAL PIPE
FLOOR PIPE PENETRATION
UL No: F-L-5014
JOINT SEALANT APPLIED
WITHIN OPENING
METAL PIPE
CONCRETE OVER COMPOSITE
STEEL DECK
MINERAL WOOL INSULATION
JOINT SEALANT
JOINT SEALANT
MINERAL WOOL
INSULATION
GLASS FIBER INSULATION
GLASS FIBER
INSULATION
METAL PIPE
SINGLE CONDUIT/PIPE PENETRATION
UL No: W-L-1063
JOINT SEALANT
PIPE / CONDUIT
JOINT SEALANT
RATED WALL ASSEMBLY - VERIFY
WALL TYPE IN FIELD
48" MAX
V A
R
IE
S
6" M
A X
2" MAX, 1" MIN
1" M
A X
MULTIPLE CONDUIT/PIPE PENETRATIONS
UL No: W-L-1063
MINERAL WOOL INSULATION
WALL TYPE, SEE PLAN
MINERAL WOOD INSULATION
MINERAL WOOL INSULATION
WALL TYPE, SEE PLAN
WALL TYPE, SEE PLAN
SINGLE CONDUIT/PIPE PENETRATION
UL No: W-L-5044
PIPE/CONDUIT
FORMING MATERIAL
JOINT SEALANT
VERIFY WALL TYPE IN FIELD
JOINT SEALANT
PIPE / CONDUIT
WALL TYPE
SMALL PENETRATIONS IN PARTITIONS
RATED UP TO 2 HOURS
NO TREATMENT REQUIRED FOR UP
TO 1/8" GAP
MAXIMUM GAP 1/4"
MAXIMUM GAP 1/2", FILL TO FULL DEPTH
OF DRYWALL AND STRIKE OFF AT FACE
OF DRYWALL, DO NOT SPREAD BEYOND
OPENING
2'-0" (PER UL)
SHALLOW FIVE SIDED BOX
RATED WALL ASSEMBLY-
SEE PARTITION TYPES FOR
NUMBER OF LAYERS OF
GYPSUM BOARD
ELECTRICAL JUNCTION BOX
16 SQ INCH MAX OPENING
MAX 100 SQ INCHES IN 100 SQ FEET
LAMINATE BACK PIECE
TO WALLBOARD
REQUIRED BOX EXCEEDS 16 SQ INCHES
OR AGGREGATE SUM OF BOXES
EXCEEDS 100 SQ INCHES IN 100 SQ
FEET OF WALL AREA
ADJACENT ELECTRICAL BOXES
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
Drawing of
11/09/2021
100% BID SET SUBMISSION 1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
674-22-801
EWMDLO
PENETRATION DETAILS
GI003
-2
-8
G I0
/1
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: NTS
A5
THROUGH PENETRATION FIRESTOP SYSTEM KEY
SCALE: NTS
F6
PENETRATION DETAIL
SCALE: NTS
F3
PENETRATION DETAIL
SCALE: NTS
A9
PENETRATION DETAIL
SCALE: NTS
D9
PENETRATION DETAIL
SCALE: NTS
D6
PENETRATION DETAIL
SCALE: NTS
D3
PENETRATIONS
SCALE: NTS
F9
ELECTRICAL JUNCTION BOX DETAIL
DANIEL L. OLIG
F
S
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
CODE DATA
OCCUPANCY HEALTHCARE
SPRINKLERS FULLY SPRINKLERED
NOTIFICATION SPEAKERS, STROBES AND COMBINATION SPEAKER-STROBES IN
NORMALL OCCUPIED AREAS
DETECTION MANUAL PULL-STATIONS, SPRINKLERS, SMOKE DETECTOR AT
FACP, CO DETECTOR AT FUEL FIRED EQUIPMENT
FIRE ALARM
ZONING
FIRE ALARM SYSTEM ZONING TO MATCH EXISTING SMOKE
ZONES
1. PROVIDE AND INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT THE BUILDING
PER THE VA DESIGN GUIDE AND NFPA 72. REFER TO SPEC SECTION 28 31 00
INTERIOR FIRE ALARM SYSTEM. FIRE ALARM SYSTEM WILL BE ZONED PER SMOKE
COMPARTMENT.
2. ALL EXISTING FIRE ALARM DEVICES, PANELS AND RELATED EQUIPMENT ARE TO
BE DEMOLISHED. EXISTING ALARM SYSTEMS MUST REMAIN IN-SERVICE AND
FUNCTIONAL WHILE NEW ALARM SYSTEM IS INSTALLED. FOLLOW ILSM
PROTOCOLS FOR SHUTDOWN AND PHASE DEMO OF EXISTING ALARM SYSTEM SO
THAT REMOVAL ONLY OCCURS ONCE NEW ALARM SYSTEM IS FULLY INSTALLED
AND FUNCTIONAL.
3. THE NEW FIRE ALARM SYSTEM SHALL REPORT TO THE NEW MAIN GRAPHIC
ANNUNCIATORS THAT WERE INSTALLED IN BUILDING 58 AND THE POLICE ROOM IN
BUILDING 204 DURING PHASE I. SEE FIRE ALARM SITE PLAN FOR DETAILS.
4. COORDINATE FIRE ALARM SYSTEM DEVICE LOCATIONS WITH LIGHT FIXTURES,
STRUCTURAL MEMBERS, SPRINKLER HEADS AND PIPING, HVAC EQUIPMENT AND
DUCTWORK.
5. ALL EXISTING INTERFACING DEVICES (TAMPERS, FLOWS, PRESSURE SWITCHES,
ETC) WILL BE CONNECTED TO THE NEW FA SYSTEM AND REPORT TO THE MAIN
GRAPHIC ANNUNCIATORS IN BUILDINGS 58, AND 204. INTERFACING DEVICES ARE
SHOWN WHEN LOCATIONS ARE KNOWN, HOWEVER THE DRAWINGS SHOULD NOT
BE USED AS AN EXHAUSTIVE LIST.
6. ALL EXISTING DOOR HOLDING/CLOSING DEVICES TO BE TIED IN TO THE NEW FA
SYSTEM AND REPORT TO THE MAIN GRAPHIC ANNUNCIATORS. EXISTING
LOCATIONS ARE SHOWN WHERE THE CLOSER IS REQUIRED FOR SMOKE
COMPARTMENTS.
7. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND
SATISFACTORILY OPERATING SYSTEMS AS INDICATED ON THE CONTRACT
DOCUMENTS AND AS EVIDENTLY INTENDED. IT IS NOTED THAT THE DRAWINGS
ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND
WORK. INTERCONNECTIONS HAVE BEEN SHOWN, AND THE CONTRACTOR SHALL
FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO ACCOMPLISH THE
FUNCTIONS INDICATED. ADDITIONALLY, FIRE ALARM SYSTEMS HAVE BEEN
SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE REQUIRED
QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER
SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED
BY THE SYSTEM MANUFACTURER, THE SPECIFICATIONS, AND ANY APPLICABLE
CODES. ALL WIRING SHOWN ON RISER DIAGRAMS SHALL ALSO BE FURNISHED
AND INSTALLED REGARDLESS OF WHETHER THESE ITEMS ARE SHOWN ON THE
FLOOR PLANS.
8. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK
OF ALL OTHER TRADES AND EXISTING CONDITIONS SO AS TO AVOID CONFLICTS.
RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO
PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE
CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY
RESULT IN REJECTION OF THE WORK.
9. ADDITIONAL DEVICES MAY BE REQUIRED. DO NOT USE THESE DRAWINGS FOR
DEVICE COUNTS.
10. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION
INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY
TESTING LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING
JURISDICTION.
11. EXISTING CONDUIT IN GOOD CONDITION THAT HAS BEEN SALVAGED FROM OTHER
BUILDINGS MAY BE REUSED IF POSSIBLE AND SHALL BE STRIPED IN PATIENT
AREAS. NEW CONDUIT SHALL BE MARKED WITH RED COUPLINGS. ALL OTHER
MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED,
AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING
LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.
12. ALL FIRE ALARM CABLES SHOULD BE INSTALLED IN METAL RACEWAYS.
13. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES AND MAY
BE EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL
ROOMS. ALL RACEWAY AND WIRING SHALL BE ROUTED EITHER PERPENDICULAR
OR PARALLEL TO THE BUILDING'S STRUCTURAL COMPONENTS.
14. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND
INSTALLATION REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE
CONCEALED IN FINISHED SPACES AND LOCATIONS SHALL BE COORDINATED WITH
THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS.
15. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX,
CABINET, PULL BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL
AND CIRCUIT NUMBER, CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER
APPROPRIATE INFORMATION. ALL PULL AND JUNCTION BOXES SHALL BE LABELED
AS TO FUNCTION.
16. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS,
HANGERS, SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT
AND PREVENT EQUIPMENT MOVEMENT. ALL EQUIPMENT LOCATED IN SEISMIC
ZONES SHALL BE SECURED WITH MEANS APPROVED FOR THE SEISMIC
CLASSIFICATION ENCOUNTERED.
17. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED
WITH FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE
CONSTRUCTION TO BE PENETRATED. PROVIDE DOCUMENTATION ON ALL SUCH
PENETRATION SEALING SYSTEMS FOR VERIFICATION OF PROPER INSTALLATION.
18. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER
WATER OR MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH
APPROPRIATE SEALING FITTINGS OR SEALED CONSTRUCTION TO PREVENT THE
INTRODUCTION OF MOISTURE INTO THE BUILDING.
19. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH
ENDS AND FITTED WITH NYLON PULLSTRINGS FOR FUTURE USE.
20. ELECTRICAL WORK SHALL BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY TO
PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE. WHERE WORK
ON EXISTING SYSTEMS WILL REQUIRE INTERRUPTION OF ELECTRICAL SERVICE,
THEN TEMPORARY PROVISIONS ACCEPTABLE TO THE OWNER FOR TEMPORARY
POWER SHALL BE UTILIZED UNTIL THE WORK IS COMPLETE.
21. THE FIRE ALARM SYSTEM SHALL COMPLY WITH ALL RELATED NFPA, BUILDING
CODES AND LOCAL FIRE DEPARTMENT REGULATIONS.
22. WALL MOUNTED FIRE ALARM PULL STATIONS ARE TO BE LOCATED 46" A.F.F. AND
WITHIN 5' OF THE NEAREST ADJACENT EXIT DOOR FROM THE FLOOR OR
BUILDING.
23. WALL MOUNTED FIRE ALARM NOTIFICATION APPLIANCES, EITHER VISUAL, OR
COMBINATION AUDIO/VISUAL, SHALL BE LOCATED SUCH THAT THE ENTIRE LENS
OF THE VISUAL PORTION IS BETWEEN 80" AND 96" A.F.F. AUDIO ONLY APPLIANCES
SHALL BE LOCATED, NOT LESS THAN 90" A.F.F. TO TOP OF APPLIANCE, OR 6"
BELOW CEILING.
FIRE ALARM GENERAL NOTES
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
DUCT SMOKE DETECTOR
AREA SMOKE DETECTOR
DOOR RELEASE SMOKE DETECTOR
S O
U N
D G
E N
E R
A L
B U
IL
D
IN
G
A
LA
R
M
X
X
N O
T
IF
Y N
E C
E S
S A
R Y
S T
A
X
INPUT
OUTPUT
N O
T
IF
Y F
IR
E
D E
P A
R M
E N
T
IN
IT
IA
T
E S
U P
E R
V
IS
O R
Y S
IG
N
A L
T O
A
4- H
O U
R M
A N
N E
D P
O
IN
O
R
IM
M E
D
IA
T E
R E
S P
O N
S E
X
C
LO
S E
A S
S O
C
IA
T E
S M
O K
E
B
R R
IE
R
D O
O R
S O
N T
H
LO
O
R
X
MANUAL PULL STATION
ELEVATOR MACHINE ROOM HEAT DETECTOR
GENERATOR ROOM HEAT DETECTOR
X
X
X
X
X
X
X
X
X
ELEVATOR SMOKE DETECTOR X X X
X
C
LO
S E
D A
M P
E R
S O
N F
N
P
R O
X
IM
A T
E T
O D
E T
E C
T O
R
X
X
S H
U T
D O
W N
A U
R H
A N
D
LE
R V
E D
B Y
T H
E D
E T
E C
T O
R
X1
1. DO NOT PROVIDE DUCT DETECTORS IN DEDICATED (100%) EXHAUST FANS, THEY SHOULD CONTINUE TO RUN.
* THIS IS THE FULL VA ALARM MATRIX, SOME ELEMENTS WILL NOT BE USED IN THIS SPECIFIC BUILDING.
R E
C A
LL
E
LE
V
A T
O R
X
IN
IT
IA
T
E E
LE
V
A T
O R
S H
U
D
W
N A
N D
D
IS
C O
N N
E C
LE
V A
T O
R P
O W
E R
X
O P
E N
L O
C K
E D
E G
R E
D
O
R S
O N
F
LO
O R
O F
F
IR
IG
IN
X
X
X
X
FIRE ALARM MATRIX
D
IS
C O
N N
E C
T F
E U
L S
O U
R C
O M
C O
O K
IN
G
E Q
U
IP
M E
N T
SPRINKLER WATERFLOW / PRESSURE SWITCH
WATER CONTROL VALVE TAMPER
FIRE PUMP
HI/LOW PRESSURE DRY PIPE SPRINKLER SYS.
KITCHEN HOOD SUPPRESSION SYSTEM
GAS EXTINGUISHING SYSTEM
DRY-PIPE VALVE ROOM TEMPERATURE ALARM
DEDICATED FIRE WATER STORAGE TANK LOW LEVEL
DEDICATED FIRE WATER STORAGE TANK LOW TEMPERATURE
X X X X X
X
X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
FIRE ALARM
CONTROL PANEL
RM 1G23
BUILDING 204
LEVEL 1
NOTE: CONTRACTOR SHALL VERIFY ALL
NECESSARY DEVICE COUNTS
LEVEL 2
LEVEL 3
CAMPUS MAIN FACP
LOCATED IN BUILDING 58 &
LEVEL 4
LEVEL 5
NOTIFICATION APPLIANCES
BASEMENT ZONE 1 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 1 FIRE/SMOKE
BASEMENT
NOTIFICATION APPLIANCES
BASEMENT ZONE 2 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 2 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 3 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 3 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 4 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 4 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 5 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 5 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 6 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 6 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 7 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 7 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 8 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 8 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 9 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 9 FIRE/SMOKE
NOTIFICATION APPLIANCES
BASEMENT ZONE 10 FIRE/SMOKE
INITIATING DEVICES
BASEMENT ZONE 10 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 1 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 1 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 2 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 2 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 4 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 4 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 5 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 5 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 6 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 6 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 7 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 7 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 1 ZONE 3 FIRE/SMOKE
INITIATING DEVICES
LEVEL 1 ZONE 3 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 1 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 1 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 2 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 2 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 4 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 4 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 5 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 5 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 6 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 6 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 7 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 7 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 2 ZONE 3 FIRE/SMOKE
INITIATING DEVICES
LEVEL 2 ZONE 3 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 3 ZONE 1 FIRE/SMOKE
INITIATING DEVICES
LEVEL 3 ZONE 1 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 3 ZONE 2 FIRE/SMOKE
INITIATING DEVICES
LEVEL 3 ZONE 2 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 4 ZONE 1 FIRE/SMOKE
INITIATING DEVICES
LEVEL 4 ZONE 1 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 4 ZONE 2 FIRE/SMOKE
INITIATING DEVICES
LEVEL 4 ZONE 2 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 5 ZONE 1 FIRE/SMOKE
INITIATING DEVICES
LEVEL 5 ZONE 1 FIRE/SMOKE
NOTIFICATION APPLIANCES
LEVEL 5 ZONE 2 FIRE/SMOKE
INITIATING DEVICES
LEVEL 5 ZONE 2 FIRE/SMOKE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSDLO
BUILDING 163 - FIRE ALARM
GENERAL NOTES AND DETAILS
163-FA001
163 1 21
-1
-1
-F
A
/2
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: NTS
A12
BUILDING 163 - FIRE ALARM RISER DIAGRAM & CAMPUS RISER DIAGRAM
DANIEL L. OLIG
UP
UP
UP
UP
UP
DN
DN
DN
DN
DN
DN
DN
DN
UP
UP
DN
UP
UP
UP
UP
UP
DN
DN
DN
DN
DN
DN
DN
UP
UP
DN
F
S
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
BD108D
N/A
BD116
BD116A BD116B
BD108E
BS-7
BD100
BD108C
BS-6
BD115
BD108B
BD108A
CB23
BD103B
BD101
BD103
BD102
BD114
BD103C
BD113
BD103A
BD111
BD112BD1100BC102BC101 CB22BD105BD104 BD107BD106ABD108A BD109
BD111A
CB21
BB
126CBC103
BB130A
BB126B
BA108
BC104
BC105
BA108
BA108BBB127A BB127
BB130
BB126
BC127B
BB126A
BC106
CB10 BS-3
CB14 CB12
CB13
BC127
BB125
BB129B
BC128 BC108 BB129A
BA108B1
BB124
BC109
BB128
BB120
BA112ABC126 BC110A
BA121F
BA121GBC110 BA121J
BA112
BC125
BA119
BC109B BC109A
BC124
BB129 BB129E BB115B
BB129C
BA121C
BA108CBB117
NOT
LABELEDBC115
NO
TAG
NO
TAG
NO
TAG
BA121H
BC111
BA117 BA121A
NO
TAGBC107 BC107A
BB129FCB16 BB116
CB15
CB6
BC114A
BC114B
NO
TAG
NO
TAG CB5
BC112
BA115NO
TAG
BA118D
BB129GBC116D
BC123 BA110BC122A BA118B
BC113
BB112E BB112F BB112G BB115A BA107 BA120BC114
BC114C
BA113
BA111 BA118G
BA109BC116C BS-2
BC122A BC122
BB113B
BA118CBB112H
NO
TAG
NO
TAG
BB112D BB113D
BA118EBB
BC116BC119B
BA106BC119
BB
BA123
BC121
NO
TAG BA104
BA118F
BA105
BB110
BA114
BC116BBC119A BC116A CB3BB112
NO
TAG
BB112B CB2BB112ABC118 BA118H
BC119 BB113ABC120
BA103
BA229
BA228BA114A
BA225
CB8 CB7CB9 BA231
BS-5
CB4NO #
BB104 CB1
BC152 BB114A BB11BB11A1 BA221BB113BC153
BA227BA200B BA222 BA224
BS-1 BA223
BC150
BA220 BA225
BC151 BC154 BA200BB100A0
BB103
BA216 BA217 BA2180 BA225ABB105 BA213BB11A BA219
BA214
BB106
BA215 BA214A
BB105
BA214A
BB108
BB107C
BA226BB109 BA210
BB114
BA211 NO #N/A N/ABB107B BB101A BA212
BC150A
BB101
BA81
BA201 BA209
BA207BA208 N/A N/AXXXX BA203
BS-12
BA206
N/A
BA204
BA205
ALARM ZONE 1
ALARM ZONE 2
ALARM ZONE 3
ALARM ZONE 4
ALARM ZONE 5
ALARM ZONE 6
ALARM ZONE 7
ALARM ZONE 8
ALARM ZONE 9
ALARM ZONE 10
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
C
D
B A
1 2
3 4
*THIS OVERALL SHEET IS PROVIDED AND INTENDED FOR FIRE ALARM ZONE
CLARITY. REFERENCE THE ENLARGED AREA PLANS FOR DEVICE LAYOUT.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSDLO
BUILDING 163 - FIRE ALARM PLAN -
BASEMENT - OVERALL
163-FA100
163 2 21
-1
-1
-F
A
/2
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1/16" = 1'-0"
A14
BUILDING 163 - FIRE ALARM PLAN - BASEMENT - OVERALL
N
DANIEL L. OLIG
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
UP
DN
DN
UP
UP
F
F
F
C
S C C
S C
S C
C
S C
S C
CC
C C C
C
C
S C
C C
C
S P
S P
C
C S C
S C
C
S C C
S C
C
C C
C
C
C S C S C
S C C S C
C S C C
C
C
C
C
S C C S C
S C
C
S C
S C C S C
C S C S C
C
S C C
S CC
C S C S C
C
S C
C
C
C
C S C
S C
S C C S C
C C
CC
C
S C S C S C C
C
C
C
CCS C
S C C C
C
F
VS VS
WF WF
DCL
D C
L
D C
L
DCL
D C
L
VS VS WF WF
DCL
S P
S
PS
P
S P
S P
S P
S
PS
P
S P
S P
S P
S P
S C
S
ID
S
ID
S
ID
S
ID
AR
S
AR
S
AR
AR
AR
VS VS
VS VS
VS
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
IT ROOMS
BB117
NOT
NOT
LABELED
PHARMACY
FLOOR
NO
TAG
PHARMACY
FLOOR
NO
TAG
PREP
BA121H
GEN. STO.
BA117
WOMEN
BA121A
PHARMACY
FLOOR
NO
TAG
ELECTRICAL
CLOSET
BB116
CORRIDOR
CB6
CORRIDOR
CB5
BA115
STERALIZATION
ROOM
NO
TAG
RESTROOM
BA118D
FIRE EQUIPMENT
HAC
BA110
MRI
BA118B
MEN
BA107
HOUSEKEEPING
CENTRAL
STORAGE
BA120
HOUSEKEEPING
EQUIPMENT RM
BA113SOILED LINEN
ROOM
BA111
CONTROL ROOM
BA118G
VCS SUPPORT
OPERATION
BA109 STAIR 2
BS-2
DRESSING ROOM
BA118C
MRI
BA118E
WOMEN
BA106
PIPE BASEMENT
ACCESS
CAN STORAGE
BA123
PHARMACY
FLOOR
NO
TAG
ELECTRICAL
ROOM
BA104
MRI
BA118F
CHIEF,
BA105
VCS STORAGE
BA114
CORRIDOR
CB3
ELEVATOR
LOBBY, SERVICE
CB2
MECHANICAL
ROOM
BA118H
IDF
BA103
MECHANICAL
ROOM
BA229
MENS ROOM
BA228
STORAGE
BA114A N & FS
BA225CORRIDOR
CB7
F.A.C.
BA231
CORRIDOR
CB4NO #
ELEVATOR
LOBBY,
PASSENGER
CB1
EMS
BA221
WOMEN ROOM
BA227NO NAME
BA200B
NUTRITION &
BA222
SITE
BA224STAIR 1
BS-1
FOOD
PROCUREMENT
BA223
OFFICE SUPPLIES
BA220
N & FS
BA225
DISHWASHING
BA200
CANTEEN
DINING/VENDING
BB100A
DINING ROOM
BB103
DIETITIAN
BA216
CHIEF, FOOD
PRODUCTION
BA217
DIET
BA218
STORAGE
BA225A RECEIVING
BA213FOOD SERVICE
BA219
CENTRAL TRAY
BA214
COOK FORMAN
BA215
STORAGE
BA214A
NO NAME
BA214A
FOOD
BA226 RECEIVING
BA210
INGREDIENT
CONTROL
BA211
MECHANICAL
ROOM
NO #
COOLER
N/A
BOX#4
N/A
VESTIBULE
BA212
DRY STORAGE
BA81
EMS
BA201
PRODUCE
BA209 MEAT
BA207
FOOD
PRODUCTION
BA208 BOX#1
N/A
BOX#3
N/A
NO NAME
XXXX
ADVANCED FOOD
BA203
STAIR 12
BS-12
INGREDIENT
CONTROL
BA206
BOX#2
N/A
CONVENTIONAL
BA204
POT & PAN
BA205
ALARM ZONE 8
ALARM ZONE 9
ALARM ZONE 10
P-1
P-2
S-3 S-4
TAMPER SWITCHES LOCATED
AT SUB-BASEMENT LEVEL
TAMPER SWITCH AT
SUB-BASEMENT LEVEL
BY STAIR 2
C
D
B
A
1 2
3 4
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSChecker
BUILDING 163 - FIRE ALARM PLAN -
BASEMENT - AREA AB
163-FA100-AB
163 3 21
-1
-1
-F
A -A
B
/0
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1/8" = 1'-0"
A16
BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA AB
N
DANIEL L. OLIG
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
UP
UP
DN
DN
DN
DN
DN
DN
DN
DN
F
F
C
S C
C
C
C
S C
C
S P
C
C C
S C
C
S C
S C
C S C
S C C
C
S C C
S C
C C C
S C C C
CC
C
C S C
CS C
C
S C
C
S C
C
S C
C
S C
S C
C
S C
VS
VSWF
D C
L
VS VS VS
VSVSVS
VS WF
DCL
S P
S P
VS
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
AR
S
AR
S
AIO
AIO
AR
AR
AR
VS
S
ID
S
ID
S
ID
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
GAS STORAGE
BD116
ELECTRICAL
ROOM
BD116A
EMERGANCY
GEN.
BD116B
TRAINING
BD108E
STAIR 7
BS-7
LMS RECEIVING
BD115
CORRIDOR
CB23
SOILED LINEN
BD114
IDF
BD113
MECHANICAL
ROOM
BD111
TRASH ROOM
BD112
CORRIDOR
CB22
A5 OFFICE
BD111A
CLOSET
BB
126C
ASST CHIEF SPS
BB126B
CONTROL ROOM
BA108
TRANSFORMER
ROOM
BA108
PIPE BASEMENT
ACCESS
MECHANICAL
ROOM
BA108B
SPS ADMIN
BB126
CHIEF SPS
BB126A
CORRIDOR
CB10
STAIR 3
BS-3
FIRE EQUIPMENT
KINESIOTHERAPY
OFFICE
BB125 ELECTRICAL
ROOM
BA108B1
KINESIOTHERAPY
BB124 WAITING/RECEPTION
BB120 STORAGE
BA112A
COLD
BA121F
AUTOPSY
BA121GCROSS
BA121J
CANTEEN RETAIL
BA112
NOT
BA119
MEN
BA121C
MORGUE
BA108C
IT ROOMS
BB117
NOT
NOT
LABELED
PHARMACY
FLOOR
NO
TAG
PHARMACY
FLOOR
NO
TAG
PREP
BA121H
GEN. STO.
BA117
WOMEN
BA121A
PHARMACY
FLOOR
NO
TAG
ELECTRICAL
CLOSET
BB116
CORRIDOR
CB6
CORRIDOR
CB5
STERALIZATION
ROOM
NO
TAG
ALARM ZONE 3
ALARM ZONE 5
S-7
ADDRESSABLE IN/OUT MONITOR
FOR POWER AND RUNNING
STATES OF FIRE PUMP
TAMPER SWITCH IN STAIR 7 AT
SUB-BASEMENT LEVEL
*IN-DUCT SMOKE DETCTORS - THREE AT
RETAIL STORE BALL 2 ON CEILING,
THREE AT PATRIOT CAFE ON CEILING
C
D
B
A
1 2
3 4
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSChecker
BUILDING 163 - FIRE ALARM PLAN -
BASEMENT - AREA ABD
163-FA100-ABD
163 4 21
-1
-1
-F
A -A
B D
/0
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1/8" = 1'-0"
A16
BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA ABD
N
FIRE PUMP LOCATION - PROVIDE
MONITORING OF POWER OFF, PHASE
REVERSAL, AND PUMP RUNNING AS
REQUIRED BY NFPA 20
DANIEL L. OLIG
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
UP
F
C S C
C S C
S C
C
S C
C
CS C
C
S C
CS C
CS CS CC
S C
S C
S C
C
C
S C
C
C C C
C S
C
S C
S P
H F
S P
VS
VS
VS
VS WF
DCL
D C
L S
P
S P
S P
S P
C
C
S C
S C
C
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
H F
AR
S
AR
S
AR
S
AR
S
AR
S
AR
S
AR
S
AR
S
AR AR
AR
VS
VS
S
ID
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
SUPPLY ROOM
BB129C
PHYSIATRY
BC115
PHARMACY
FLOOR
NO
TAG
PHARMACY
FLOOR
NO
TAG
STAFF
PHYSIATRIST
BC111 CHIROPRACTIC
OFFICE
BC107
CHIROPRACTIC
EXAM ROOM
BC107A
DRESSING ROOM
BB129F
CORRIDOR
CB16
CORRIDOR
CB15
SUPERVISOR
OFFICE PHYSICAL
THERAPY
BC114A
SUPERVISOR
OFFICE
KINESIOTHERAPY
THERAPY
BC114B
OFFICE
NO
TAG
OFFICE
NO
TAG
EXAM ROOM
BC112
STERALIZATION
ROOM
NO
TAG
PUMP ROOM
BB129G
SLP LAB &
TREATMENT RM.
BC116D
ELECTRICAL
ROOM
BC123EXAM ROOM
BC122A ADPAC
BC113
ASSISTANT CHIEF
PHARMACY
SERVICE
BB112E
PROGRAM
SPECIALIST
BB112F
CHIEF
PHARMACY
SERVICE
BB112G
CONT. SUB.
VAULT
BB115A
CLINICAL
COORDINATOR
BC114
SUPERVISOR
OFFICE
OCCUPATIONAL
THERAPY
BC114C
COMPUTER
ROOM
BC116CEXAM ROOM
BC122A
STAFF
PHYSIATRIST
BC122 OFFICE
BB113B
OFFICE
CBOC
BB112H OFFICE
NO
TAG
RESTROOM
NO
TAG
CLINICAL
COORDINATOR
BB112D
CONFERENCE
ROOM
BB113D
PHARMACY
SERVICE
BB
SPEECH &
LANGUAGE
PATHOLOGY
BC116
EXAM ROOM
BC119B
OFFICE
BC119
COORIDOR
BBPSYCHOLOGIST
BC121
PHARMACY
FLOOR
NO
TAG
PHARMACY
SERVICE
BB110
SPEECH
PATHOLOGIST
BC116B
CHIEF PM & RS
BC119A
SPEECH
PATHOLOGIST
BC116A
PHARMACY
SERVICE
BB112
BREAKROOM
NO
TAG
ADMIN OFFICE
BB112B
CLERKS
BB112A
STORAGE
BC118
SECRETARY PM &
RS
BC119
ADPAC
BB113A
SLP SUPERVISOR
BC120
CORRIDOR
CB8
CORRIDOR
CB9
STAIR 5
BS-5
STAFF ONLY
BB104
STORAGE
BC152
RADIOACTIVE
WASTE STORAGE
BB114A
TELEPHONE
BB11
NO TAG
BB11A1
MECH ROOM
BB113
NOT LABELED
BC153
MECHANICAL
ROOM
BC150
ELEVATOR
MACHINE ROOM
BC151
ELECTRICAL
ROOM
BC154
CORRIDOR
0 DINING ROOM
BB103
CORRIDOR
STORAGE
BB105NO TAG
BB11A
EMS
BB106
STORAGE
BB105
ELECTRICAL
BB108
WALK-IN 1
BB107C
CANTEEN
BB109
MECH ROOM
BB114
WALK-IN 2
BB107B
STORAGE
BB101A
MECHANICAL
ROOM
BC150A
KITCHEN
BB101
ALARM ZONE 6
ALARM ZONE 7
ALARM ZONE 8P-12 P-11
FA05
*TWO DUCT DETECTORS AT AHU-1,
ONE DETECTOR ON CEILING
TAMPER SWITCHES IN
STAIR 5 AT SUB-
BASEMENT LEVEL
C
D
B
A
1 2
3 4
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSChecker
BUILDING 163 - FIRE ALARM PLAN -
BASEMENT - AREA BC
163-FA100-BC
163 5 21
-1
-1
-F
A -B
C
/0
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1/8" = 1'-0"
A16
BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA C
KEYNOTE LEGEND
FA05 HEAT DETECTOR IN ELEVATOR MACHINE ROOM TO REMOVE POWER PRIOR TO
DISCHARGE FROM SPRINKLERS.
N
DANIEL L. OLIG
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
UP
F
F
C
S C
S C
S C
C
C
C S C
S C C
S C
C
S P
H F
S P
C
C S C S C
C
S C
C
C S C
C S C S C
C
S C
S C
C S C S C C
C
C
C S C C CC
C
S C
S C S C S C
CS CS C
S CC
S C C
C S C
C S C
S C
C C
S C
C
C
C
C
VS
DCL DCL
D C
L
S P
S P
S P
S P
D C
L
S P
S P
DCL
S P
S P
S P
S P
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
S
ID
H F
H F
H F
AR
S
AR
S
AR
S
AR
S
AR
AR
AR
AR
VS
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
HOUSEKEEPING
BD108D
BACK OF
STERILIZER
N/A
LMS STORAGE
BD100
SPD
BD108C
STAIR 6
BS-6
CART LIFT
BD108B
LMS
DISTRIBUTION
BD108A
ELEVATOR
LOBBY
AUTOMATIC CART
WASHER
BD103B
SPD MALE
DECON/
BD101
SPD
DECONTAMINATION
BD103
SPD FEMALE
DECON/
BD102
SUPPLY
BD103C
HOUSEKEEPING
BD103A
ELEC. ROOM
BD110
CORRIDOR
ELEVATOR
EQUIPMENT
BC102
MECHANICAL
ROOM
BC101
SPS ECUCATOR
BD105
CART LIFT
MECHANICAL RM
BD104
COMPUTER
BD107
CHIEF,
BD106A
MSD&E SECTION
BD108A
ELE.
BD109
CORRIDOR
CB21
COMMUNICATIONS
ROOM
BC103
RESEARCH
STORAGE
BB130A ASST CHIEF SPS
BB126BLMS EQUIPMENT
STORAGE
BC104 HAC
BC105
PT OFFICE
BB127A
PHYSICAL
THERAPY
BB127
RESEARCH
BB130
RESTROOM, MEN
BC127B
CHIEF SPS
BB126A
ELECTRICAL
ROOM
BC106
CORRIDOR
CB14 CORRIDOR
CB12
CORRIDOR
CB13 FIRE EQUIPMENT
LOCKER ROOM,
MEN
BC127
KINESIOTHERAPY
OFFICE
BB125
WOMEN SHOWER
BB129B
STAFF
PHYSIATRIST
BC128
EXAM ROOM
BC108
MEN SHOWER
BB129A
KINESIOTHERAPY
BB124
OCCUPATIONAL
THERAPY
BC109
KINESIOTHERAPY
BB128
OFFICE
BC126
EXAM ROOM
BC110A PHYSIATRIC
CLINIC
BC110
EXAM ROOM
BC125
OFFICE
BC109B
OFFICE
BC109A
LOCKER ROOM,
WOMEN
BC124
THERAPEUTIC
POOL
BB129 LINEN ROOM
BB129E
HOUSEKEEPING
BB115B
SUPPLY ROOM
BB129C
PHYSIATRY
BC115
PHARMACY
FLOOR
NO
TAG
PHARMACY
FLOOR
NO
TAG
STAFF
PHYSIATRIST
BC111 CHIROPRACTIC
OFFICE
BC107
CHIROPRACTIC
EXAM ROOM
BC107A
DRESSING ROOM
BB129F
CORRIDOR
CB16
CORRIDOR
CB15
SUPERVISOR
OFFICE PHYSICAL
THERAPY
BC114A
SUPERVISOR
OFFICE
KINESIOTHERAPY
THERAPY
BC114B
OFFICE
NO
TAG
OFFICE
NO
TAG
EXAM ROOM
BC112
STERALIZATION
ROOM
NO
TAG
ALARM ZONE 1
ALARM ZONE 2
ALARM ZONE 4
S-7
P-5
P-6
FA05
*TWO DUCT DETECTORS
LOCATED AT AHU-1 AND
AHU-2
TAMPER SWITCH IN STAIR 6 AT
SUB-BASEMENT LEVEL
C
D
B A
1 2
3 4
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSChecker
BUILDING 163 - FIRE ALARM PLAN -
BASEMENT - AREA BCD
163-FA100-BCD
163 6 21
-1
-1
-F
A -B
C D
/0
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1/8" = 1'-0"
A16
BUILDING 163 - FIRE ALARM PLAN - BASEMENT - AREA BCD
KEYNOTE LEGEND
FA05 HEAT DETECTOR IN ELEVATOR MACHINE ROOM TO REMOVE POWER PRIOR TO
DISCHARGE FROM SPRINKLERS.
N
DANIEL L. OLIG
DN
UP
UP
UP
UP
UP
UP
UP
UP
DN
UP
DN
DN
DN
DN
DN
DN
DN
DN
F
S
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
ALARM ZONE 1
ALARM ZONE 2
ALARM ZONE 3
ALARM ZONE 1
ALARM ZONE 5
ALARM ZONE 4
ALARM ZONE 6
ALARM ZONE 7
1D108C 1D124A 1D101A 3
1D124 1D108A
1D105 1D108 1D101B 1D101C1D101 1D123
1D1091D100
1D1061D103
1D122
1D121
1C41 1S6
1D
1K
1D1201D110 1D122A1D1191D107
1D111
1D104A
1D102 1D114 1D118 6
1D1271D112 1D116
1C29
1D1171D104B
1D1131D104C 1D115
1C30 1A126A 1A118 1A121A
1A1291A126 1A130A1B172 1A1281B150B 1A1231A117 1A123A1C36C 1A1198
1B1651C31 1B154A 1B1711B164
1A121 1B160 1B164B 1A1A115A1C32
1B150C
1B150
1A1301C33 1A12711 1A1151B154D 1B1691B1661B164A
1A124B 1A124A1C36 1A132
1A11412 1A1201B163 1A1311B158 1B150A1B155 1A1221A1131B156 1A1341B1681B167 1B152 1B151
1A112B 1A112D 1A120A 1A148 131A120B14 1A136A 1A136B 1A135
1A112C 1A147
1A112A
1A1361A109A 1B153
1B162C 16 1C35 1B149 1A137
1A152A1C02E 171C18 1A111 1A1461B1621B162A1C16
1A144A 1A111A
1A138 1C02D
1A142A 1A152D1A152C1C411C151C13 1A1411A144
1C14 1B172B 1A10918 1A110
1A1521B1721B148 1B172A 1B162B1B173 1A1421A110B 1A1391C38 1B147 1C1119 1A1501A110A
1C40
1C12
20 21 1A133
1C39
1C02C 1A1431A151
1B23 1A145A1B22 1B24 1B2301C10 1B2051C09 1A1081B231 1B2031B201 1A140 221B204
1A1451C02 1B251B21
1C01 1B229 1B2061C07 1C08 1B26 C1-28
1A1051B20 1A155C1B228 1A103 1A1541B227 1A145CC1-271B27
1B2021B19A 1B173J1B28 1B207
241B209 C1-29 251B226C1-18A 1A155B1B29 1A1071B225 1B210
1B30
1A145G
1A104C1-52 1A145B
1B19 1C05 1C031C04 26 1B208 1A106 1A145J
1A1551A170A1B31 1S5 C1-19D
1B32 1B224 1B200C1-32 1A155A
1A179 1A170 1A178
1B175 1A169 1A169A1B34 1A155D1B2231B33 1A1561A182
1B21127 1B176A
1A18528 1A177C1-20 1B351B41 1A172 1A1741B222
1B1761B44 1B221
1A176 1A1871B178 29 1A157
1B361C153
1B18 30 C1-21 1B2151B220 C1-33
1B2191B37 1B77B1C154 1B43 1B40
1A101 1A158A1C168 1A181 1A1831C176 1B38 C1-311C1551C170 1B79A1B391B42 1A1711B17 1A184
1A1861B18A C1-22C1-51 1B2121C173 1A1581A1801A1681C1721C167 1C178 1B180A1B02 1A1731B218
1A1671C156 1B2171B79 1B216 1B214 1B2131C157 1B81B1B81A1B16 1B801C169 1C177 1A164 1A163
1A1611C166
1A159B32 33 1A166A 1A159C1B
1A166 1A160B1A164B1C165B
1B15 1B13 1B101B12 1B09 1B041B061B08 1B051B071C163 1C162 1E1481C1591C160 1A164D 1A1601A164A 1A1621A165A 1A1591C161 1A164E 1A165 1A164F 1A159A
1A164C
1B3421B332
1B336 1B3381B337 1B3391B334 1B3351B330 1B331 1B3411B340
1B333
1B011B343
1B35935
1B356 1B3721B366 1B3671B3651B364 1B369 1B3711B3701B3681B363
1B302
1B353 1B3501B351 1B349 1B3471B3481B352 1B3461B355 1B345 1B344
1B373
1B303
1B316 1B3151B317 1B314 1B311 1B3101B313 1B312 1B309 1B3061B308 1B307 1B305
1B304
1D104
1B174
1B170
1A145D
1A145E
1E1001E101
1E102
1E103
1E104 1E105
1E106
1E107
1E108 1E109 1E110 1E111 1E112
1E113
1E114 1E115 1E116 1E117 1E118
1E119
1E120
1E121
1E122
1E123
1E1241E125
1E126
1E1301E131
1E132
1E133
1E134 1E135
1E136 1E137 1E141 1E142
1E143 1E144
1E145
1E146
1E1471E149
1E150 1E1511E1521E153
1E156
1E157 1E158
1E1591E160
1E161
1E1621E1631E164 1E1651E1671E168
1E169
1E170
1E171
1E172
1E173
1E174
1E166
1E157A
C1-52A
1D108E
1D108F
1D108G
1D108H
1B154
C1-28A
1D122B
1D122C
1C06
1C11A
1C02A
1C02B
1C27 1C27A
1C27B
1C21A
1C21
1C24
1C22
1C22A 1C23A
1C23
1C28
1C26
1C25
1C27C
C1-21
1C27D
1A160A
1C02G 1C02H
1B354
1A175
1A155E
1D108B
FIRE ALARM SYMBOLS
DEVICES
WEATHERPROOF SPEAKER/STROBE
SYMBOL DESCRIPTION
DETECTORS
MANUAL PULL STATION
SPEAKER ONLY CEILING MOUNTED
COMBINATION OF SPEAKER/STROBE WALL MOUNTED
SPEAKER ONLY WALL MOUNTED
STROBE ONLY CEILING MOUNTED
STROBE ONLY WALL MOUNTED
MNS SPEAKER/STROBE CEILING MOUNTED
GAS DETECTOR - CARBON MONOXIDE
HEAT DETECTOR - FIXED TEMPERATURE ONLY
SMOKE DETECTOR - IN DUCT
SMOKE DETECTOR - PHOTOELECTRIC
SWITCHES
FLOW DETECTOR/SWITCH
TEMPERATURE SUPERVISORY SWITCH
VALVE SUPERVISORY SWITCH
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
PANELS
LINE TYPES
SMOKE/ALARM ZONE BOUNDARY LINES
DOOR HOLDER
DOOR CLOSER
W
ADDRESSABLE RELAY
ADDRESSABLE RELAY - FIRE SHUTTER
ADDRESSABLE RELAY - FAN SHUTDOWN
REMOTE TEST SWITCH
ADDRESSABLE INPUT/OUTPUT MODULE
C
D
B A
1 2
5 6
3 4
E
CODE DATA
OCCUPANCY HEALTHCARE
SPRINKLERS FULLY SPRINKLERED
NOTIFICATION SPEAKERS, STROBES AND COMBINATION SPEAKER-STROBES IN
NORMALL OCCUPIED AREAS
DETECTION MANUAL PULL-STATIONS, SPRINKLERS, SMOKE DETECTOR AT
FACP, CO DETECTOR AT FUEL FIRED EQUIPMENT
FIRE ALARM
ZONING
FIRE ALARM SYSTEM ZONING TO MATCH EXISTING SMOKE
ZONES
*THIS OVERALL SHEET IS PROVIDED AND INTENDED FOR FIRE ALARM ZONE
CLARITY. REFERENCE THE ENLARGED AREA PLANS FOR DEVICE LAYOUT.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
LEO A DALY
730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Melisa Rodriguez
ARCHITECT:
CB DESIGN GROUP
421 KING ST., SUITE 301
ALEXANDRIA, VA 22314
POC: WES BRIDGES
703.772.4213
PROFESSIONAL SEAL:
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
FULLY
SPRINKLERED Drawing of
ADDENDUM 1 02/03/2023
11/09/2021
100% BID SET SUBMISSION B163 - TEAGUE TOWER HOSP.
1901 VETERANS MEMORIAL DRIVE
TEMPLE, TX 76504
617-19-102
CSSDLO
BUILDING 163 - FIRE ALARM PLAN -
LEVEL 1 - OVERALL
163-FA101
163 7 21
-1
-1
-F
A
/2
/2
.p d f
TEMPLE VA MEDICAL CENTER - FIRE
ALARM CAMPUS UPGRADE
SCALE: 1" = 20'-0"
A16
BUILDING 163 - FIRE ALARM PLAN - LEVEL 1 - OVERALL
N
DANIEL L. OLIG
S C
M
C
CO
H F
S
ID
S P
WF
TSS
VS
FAA
FACP
FATC
DH
DCL
AR
AR
FS
AR
S
RTS
AIO
UP
UP
UP
DN
DN
DN
F
F
S C C C
C
S C
C S C
S C C
C
S C
C
CS C
C
S C S C C
C
C
C
C
C
C
C
C
S C
C
C
CS CS CS C
CS C
C
C
C
C
S C
C
S C
C
C
CS CCC
S C
C
C
C
C
S C
C
C
S C
C
C
C
C
C
C S C
C
C
C
S P
S P
F
C VS
VS VS
WF
WF WF
D C
L
DCL
S P
S P
S P
S P
DCL
S P
S…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .