36C25718Q0546-018.pdf
PDF 6 MB Posted
- Solicitation number
- 36C25718Q0546
About this file
36C25718Q0546 Drawings Waco Dampers.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25718C0099-000.docx | DOCX document | |
| 36C25718Q0546-00001002.pdf | ||
| 36C25718Q0546-00001001.pdf | ||
| 36C25718Q0546-00001000.docx | DOCX document | |
| 36C25718Q0546-014.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-011.pdf | ||
| 36C25718Q0546-015.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-012.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-016.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-013.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-010.docx | DOCX document | |
| 36C25718Q0546-017.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-009.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
UP
UP
EX
EX
EX
EX
33.82 SF
ELECTRICAL
BA130
50.76 SF
WOMEN
RESTROOM
BA125B
223.96 SF
NURSING
OFFICE
CB15
49.09 SF
MENS
RESTROOM
BA125A
217.87 SF
WAITING AREA
CB2B
211 SF
CORRIDOR
CB5
49.78 SF
HOUSEKEEPING
BA166
129.27 SF
WOMEN
RESTROOM
BA164
89.32 SF
EMPLOYEE
HEALTH
BB103-D
771.57 SF
CORRIDOR
CB23
STORAGE,
GENERAL
BA139
36.4 SF
COFFEE BAR
BA173
185.54 SF
CONTROLLED
NARCOTICS
BB104
230.25 SF
ELECTRICAL
ROOM
BA172
100.61 SF
PHARMACIST
BA169
1,600.05 SF
PHARMACY
BB104A
91.68 SF
EXAM ROOM
BA117
100.71 SF
EXAM ROOM
BA112
90.09 SF
EXAM ROOM
BA109
55.37 SF
HAC
BB102
269.97 SF
PHARMACY
BREAK ROOM
BB103
164.63 SF
PATIENT REP
BA170
631.17 SF
MECHANICAL
ROOM
BA171
134.6 SF
EMS STORAGE
BB100
125.22 SF
MED SUPPLY
STORAGE
BA115
119.23 SF
AMBULANCE
ENTRANCE
CB2C
97.27 SF
RESTROOM
BA110
199.91 SF
TREATMENT
ROOM
BA106
186.94 SF
TREATMENT
ROOM
BA107
195.16 SF
EXAM ROOM
BA111
105.12 SF
EXAM ROOM
BA113
107.87 SF
AMBULATORY
CARE DESK
BA114
104 SF
EXAM ROOM
BA153
60.89 SF
MEANS TEST
BA101B
60.23 SF
PROCESSING/REGISTRATION
BA101C
62.21 SF
VET ID CARD
BA101A
245.98 SF
WAITING AREA
CB2A
192.93 SF
MENS
RESTROOM
BA168
108.39 SF
PRIMARY CARE
OFFICE
BA163
305.92 SF
CAFE
BB101
20.06 SF
CLEAN LINEN
CB-18A
20.01 SF
SOILED LINEN
CB-18B
137.27 SF
PHARMACY
HELP LINE
BB103B
303.48 SF
PHARMACY
WAITING
BB103-C
89.09 SF
EMPLOYEE
HEALTH NURSE
BB103-E
108.48 SF
EXAM ROOM
BA161
94.48 SF
PHARMACY
BA162
1,060.97 SF
CORRIDOR
CB2
444.29 SF
CORRIDOR
CB20
208.16 SF
CORRIDOR
CB10
Redundant Room
CORRIDOR
CB4
176.19 SF
CORRIDOR
CB17
139.03 SF
CORRIDOR
CB11
880.77 SF
CORRIDOR
CB8
114.63 SF
CORRIDOR
CB16
152.96 SF
CORRIDOR
CB20
247.84 SF
ELEVATOR
LOBBY
CB-18
98.36 SF
ELEVATOR
MACHINE ROOM
BA100
79.65 SF
STAIR 2
BAS2
102.03 SF
STORAGE
NO LABEL
49.31 SF
SUB BSMT
ACCESS
241.83 SF
VIDEO ROOM
BA105
28.46 SF
133.95 SF
STAIR 6
BAS6
110.94 SF
STAIR 5
BAS5
208.73 SF
TREATMENT
ROOM
BA157
59 SF
EXAM/OFFICE
BA160
93.96 SF
EXAM ROOM
BA156
84.06 SF
EXAM
BA159
65.98 SF
DISPOSITION
AREA
BA123
121.94 SF
SOCIAL
WORKER
BA129
59.01 SF
OFFICE
BA124
123.03 SF
EXAM ROOM
BA121
129.11 SF
MAROON TEAM
CHECK-IN DESK
BA122
169.46 SF
WAITING AREA
BA149
90.19 SF
NURSING
INTERVEIW
ROOM
BA152
51.17 SF
UNISEX
RESTROOM
BA145B
163.25 SF
CORRIDOR
CB14
98.55 SF
IMAGING
RECEPTION
BA146
116.7 SF
EXAM ROOM
BA155
146.26 SF
WAITING AREA
BA149
Redundant Room
CORRIDOR
CB15
86.52 SF
EXAM ROOM
BA154
78.58 SF
FORM
STORAGE
BA101A
113.5 SF
SUPERVISOR
BA103
105.44 SF
OFFICE
BA116
550.72 SF
INFORMATION
RECEPTIONIST
BA101
26.36 SF
ELECTRICAL
BA119
11.81 SF
COMMUNICATIONS
CLOSET
BA120
114.92 SF
CLINIC
MANAGER
BA118
43.56 SF
CLEAN LINEN
ROOM
BA103-3
176.6 SF
EXAM ROOM
BA105
35.84 SF
SOILED UTILITY
BA103-2
56.69 SF
STORAGE,
EQUIPMENT
BA103-1
12.95 SF
OXYGEN
BA103-4
125.81 SF
EXAM ROOM
BA167
45.13 SF
HOUSEKEEPING
BA127
91.05 SF
NURSE
BA126
174.99 SF
STAFF LOUNGE
BA125
349.93 SF
VESTIBULE
CB1
187.94 SF
MULTI
PURPOSE
ROOM
BA165
296 SF
CORRIDOR
CB3
89.94 SF
NURSE LOCKER
ROOM
BA128
166.12 SF
WAITING AREA
BA149
66.61 SF
CORRIDOR
XXX
131.04 SF
PROGRAM
CLERK
BA132
174.15 SF
NURSE
MANAGER
BA131
51.74 SF
MENS
RESTROOM
BA137
108.63 SF
OFFICE
BA133
125.09 SF
NUTRITION
CLINIC
DIETITION
BA129A
81.23 SF
WAITING AREA
B13A
290.35 SF
CORRIDOR
CB12
242.84 SF
PATIENT FUNDS
BA138
174.84 SF
TRAVEL
BA134
48.79 SF
WOMENS
RESTROOM
BA136
135.41 SF
STAIR 1
BAS1
43.75 SF
SUB BASEMENT
ACCESS
NO LABEL
212.51 SF
AGENT
CASHIER
BA135
189.25 SF
CORRIDOR
CB13
143.81 SF
ULTRASOUND
BA147A
85.94 SF
IMAGING
EDUCATION
BA144
37.14 SF
STORAGE,
GENERAL
BA147A
89.95 SF
TECH OFFICE
BA143
411.48 SF
CT SCAN
BA145
119.57 SF
IMAGING
MANAGEMENT
BA148
110.19 SF
CT CONTROL
BA145A
57.97 SF
IMAGING
OFFICE
BA142
273.43 SF
X-RAY IMAGING
BA140
121.72 SF
VESTIBULE
XXX
109.93 SF
DIGITAL
PROCESSING
BA141A
270.43 SF
X-RAY IMAGING
BA141
45.67 SF
RESTROOM
BA140A
45.33 SF
TOILET
BA163A
EX
EX
OPEN
CANOPY
CHASE
BB100A
CONSULTANTS, INC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER LIST
Damper Condition
FD-B-001 E
FD-B-002 B
SD-B-003 J
FD-B-004 B
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Not Required Smoke Barrier with Automatic Sprinklers per NFPA 101, 21.3.7.6
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Not Required Smoke Barrier with Automatic Sprinklers per NFPA 101, 21.3.7.6
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-A-001 B
FD-A-001A A
FD-A-002 A
FD-A-003 A
FD-A-004 A
FD-A-005 A
FD-A-006 A
FD-A-007 A
FD-A-008 B
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-A-001 Not Accessed
FD-A-002 B
FD-A-003 B
FD-A-004 B
FD-A-005 B
FD-A-006 B
FD-A-007 B
FD-A-008 B
FD-A-009 B
FD-A-010 B
FD-A-011 B
FD-A-012 B
FD-A-013 B
FD-A-014 B
EX
EX
EX
EX
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-B-001 A
FD-B-002 K
FD-B-003 A
FD-B-004 A
FD-B-005 K
FD-B-006 A
FD-B-007 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-1-001 A
FD-1-002 A
FD-1-003 A
FD-1-004 K
FD-1-005 K
FD-1-006 A
FD-1-007 A
FD-1-008 A
FD-1-009 A
FD-1-010 K
FD-1-011 K
FD-1-012 A
FD-1-013 A
FD-1-014 K
FD-1-015 K
FD-1-016 K
FD-1-017 A
FD-1-018 A
FD-1-019 A
FD-1-020 A
FD-1-021 K
FD-1-022 K
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-2-001 Not Located in Field
FD-2-002 A
FD-2-003 A
FD-2-004 A
FD-2-005 K
FD-2-006 A
FD-2-007 A
FD-2-008 A
FD-2-009 A
FD-2-010 K
FD-2-011 K
FD-2-012 K
FD-2-013 A
FD-2-014 A
FD-2-015 Not Located in Field
FD-2-016 K
FD-2-017 A
FD-2-018 A
FD-2-019 K
FD-2-020 A
FD-2-021 A
FD-2-022 K
FD-2-023 K
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-B-001 E
FD-B-002 E
FD-B-003 A
FD-B-004 A
FD-B-005 A
FD-B-006 D
FD-B-007 D
FD-B-008 A
FD-B-009 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Not Required Smoke Barrier with Automatic Sprinklers per NFPA 101, 21.3.7.6
DAMPER LIST
Damper Condition
FD-1-001 A
FD-1-002 E
FD-1-003 E
FD-1-004 E
FD-1-005 E
FD-1-006 E
FD-1-007 A
FD-1-008 A
FD-1-009 K
FD-1-010 NOT LOCATED IN FIELD
FD-1-011 K
FD-A-009 B
FD-A-010 B
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-1-001 A
FD-1-002 K
FD-1-003 K
FD-1-004 A
FD-1-005 A
FD-1-006 F
FD-1-007 K
FD-1-008 E
FD-1-009 K
FD-1-010 A
FD-1-011 A
FD-1-012 K
FD-1-013 A
FD-1-014 K
EXEX
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-2-001 A
FD-2-002 A
FD-2-003 K
FD-2-004 K
FD-2-005 A
FD-2-006 K
FD-2-007 K
FD-2-008 E
FD-2-009 K
FD-2-010 Not Located in Field
FD-2-011 Not Located in Field
FD-2-012 Not Located in Field
FD-2-013 A
FD-2-014 A
FD-2-016 K
FD-2-017 K
FD-2-018 A
FD-2-019 K
FD-2-020 K
FD-2-021 K
FD-2-022 K
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork from a mechanical shaft opening to a 1 hour rated Mechanical Room
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-2-001 K
FD-2-002 A
FD-2-003 A
FD-2-004 A
FD-2-005 A
FD-2-006 A
FD-2-007 A
FD-2-008 A
FD-2-009 A
FD-2-010 A
FD-2-011 A
FD-2-012 A
FD-2-013 A
FD-2-014 A
FD-2-015 A
FD-2-016 A
FD-2-017 A
FD-2-018 A
FD-2-019 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork from a mechanical shaft opening to a 1 hour rated Mechanical Room
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-A-001 B
FD-A-002 B
FD-A-003 B
FD-A-004 B
FD-A-005 B
FD-A-006 B
FD-A-007 B
FD-A-008 B
FD-A-009 B
FD-A-010 B
FD-A-011 B
FD-A-012 B
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER LIST
Damper Condition
FD-B-001 E
FD-B-002 E
FD-B-003 E
FD-B-004 E
FD-B-005 E
FD-B-006 H
FD-B-007 I
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork from a mechanical shaft opening to a 1 hour rated Mechanical Room
J Not Required Smoke Barrier (with Quick Response)
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Air Handler Supply/Return
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-1-001 B
FD-1-002 B
FD-1-003 A
FD-1-004 A
FD-1-005 A
FD-1-006 E
FD-1-007 E
FD-1-008 E
FD-1-009 E
FD-1-010 E
FD-1-011 E
FD-1-012 E
FD-1-013 E
FD-1-014 E
FD-1-015 E
FD-1-016 E
FD-1-017 E
FD-1-017A B
FD-1-018 B
FD-1-019 B
FD-1-020 A
FD-1-021 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork from a mechanical shaft opening to a 1 hour rated Mechanical Room
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-1-001 A
FD-1-002 A
FD-1-003 A
FD-1-004 A
FD-1-005 A
FD-1-006 A
FD-1-007 A
FD-1-008 A
FD-1-009 A
FD-1-010 A
FD-1-011 A
FD-1-012 A
FD-1-013 A
FD-1-014 A
FD-1-015 A
FD-1-016 A
FD-1-017 A
FD-1-018 A
FD-1-019 A
FD-1-020 A
FD-1-021 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Air Handler Supply/Return
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
S-2-001 C
FD-2-002 B
S-2-003 C
S-2-004 C
S-2-005 C
FD-2-006 A
FD-2-008 B
FD-2-009 A
FD-2-010 A
S-2-011 C
S-2-013 C
S-2-014 C
FD-2-015 K
FD-2-016 K
FD-2-017 K
FD-2-018 K
FD-2-019 K
FD-2-020 K
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Air Handler Supply/Return
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-A-001 A
FD-A-002 A
FD-A-003 A
FD-A-004 A
FD-A-005 A
FD-A-006 A
FD-A-007 A
FD-A-008 A
FD-A-009 A
FD-A-010 A
FD-A-011 A
FD-A-012 A
FD-A-013 A
FD-A-014 A
FD-A-015 A
FD-A-016 A
FD-A-017 A
FD-A-018 A
FD-A-019 A
FD-A-020
NOT FIELD
LOCATED
FD-A-021 A
FD-A-022 A
FD-A-023 A
FD-A-024 A
FD-A-025 A
FD-A-026 A
FD-A-027 A
FD-A-028 A
FD-A-029 A
FD-A-030 A
FD-A-031 A
FD-A-032 A
FD-A-033 A
FD-A-034 A
FD-A-035 A
FD-A-036 A
FD-A-037 A
FD-A-038 A
FD-A-039 A
FD-A-040 A
FD-A-041 A
FD-A-042 A
FD-A-043 A
FD-A-044 A
FD-A-045 A
FD-A-046 A
FD-A-047 A
FD-A-048 A
FD-A-049 A
FD-A-050 A
FD-A-051 A
FD-A-052 A
FD-A-053 A
FD-A-054 A
FD-A-055 A
FD-A-056 A
FD-A-0XX A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Air Handler Supply/Return
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-B-001 A
FD-B-002 A
FD-B-003 E
FD-B-004 E
FD-B-005 E
FD-B-006 E
FD-B-007 E
FD-B-008 E
FD-B-009 E
FD-B-010 E
FD-B-011 A
FD-B-012 A
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-A-001 B
FD-A-002 B
FD-A-003 B
FD-A-004 B
FD-A-005 B
FD-A-006 B
FD-A-007 B
FD-A-008 B
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-1-001 B
FD-1-002 A
FD-1-003 A
FD-1-004 A
FD-1-005 B
FD-1-006 A
FD-1-007 A
FD-1-008 A
FD-1-009 A
FD-1-010 B
INDIANAPOLIS, IN 46224
(317)486-5188
FP&C
DAMPER KEY PLAN
Type Condition Requirement
A Required Fire Rated Shaft
B Required Fire Rated Floor
C Required Smoke Barrier (without Quick Response)
D Required Fire Rated Wall
E Not Required Non Rated Partition Wall
F Not Required Hazardous Room now Sprinklered
G Not Required Smoke Barrier Deleted in Business Occupancy
H Not Required Not Required for a Duct Through Penetration in a 1 Hour Fire Barrier
I Not Required Not Required at Ductwork Termination in a 1 hour Fire Barrier
J Not Required Smoke Barrier (with Quick Response)
K Not Required Exhaust Riser Exemption Per NFPA 90A, 5.3.4.6.2
DAMPER LIST
Damper Condition
FD-2-001 K
FD-2-002 K
FD-2-003 K
FD-2-004 A
FD-2-005 A
FD-2-006 A
FD-2-007 K
FD-2-008 K
FD-2-009 B
FD-2-010 B
FD-2-011 B
FD-2-012 A
FD-2-013 A
FD-2-014 A
FD-2-015 K
FD-2-016 K
| Drawing BLDG 4 Basement.pdf |
| Drawing BLDG 4 Mechanical Level |
| Drawing BLDG 7 Attic |
| Drawing BLDG 7 Basement |
| Drawing BLDG 7 First Floor |
| Drawing BLDG 7 Second Floor |
| Drawing BLDG 10 Basement |
| Drawing BLDG 4 First Floor |
| Drawing BLDG 10 First floor |
| Drawing BLDG 10 Second floor |
| Drawing BLDG 11 Dampers 2st Floor |
| Drawing BLDG 11 Dampers Attic |
| Drawing BLDG 11 Dampers Basement |
| Drawing BLDG 91 Dampers 1st Floor |
| Drawing BLDG 11 Dampers 1st Floor |
| Drawing BLDG 91 Dampers 2nd Floor |
| Drawing BLDG 91 Dampers Attic |
| Drawing BLDG 91 Dampers Basement |
| Drawing BLDG 94 Damper 1st Floor 2view |
| Drawing BLDG 94 Damper 1st Floor |
| Drawing BLDG 94 Damper 2nd Floor |