36C25718Q0546-016.xlsx
XLSX spreadsheet 35 KB Posted
- Solicitation number
- 36C25718Q0546
About this file
36C25718Q0546 Waco 91 Damper Report FINAL.xlsx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25718C0099-000.docx | DOCX document | |
| 36C25718Q0546-00001002.pdf | ||
| 36C25718Q0546-00001001.pdf | ||
| 36C25718Q0546-00001000.docx | DOCX document | |
| 36C25718Q0546-014.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-011.pdf | ||
| 36C25718Q0546-015.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-012.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-018.pdf | ||
| 36C25718Q0546-013.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-010.docx | DOCX document | |
| 36C25718Q0546-017.xlsx | XLSX spreadsheet | |
| 36C25718Q0546-009.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| Texas Fire Suppression, Inc | ||||||||||||
| 100-B Don Currie Dr. | ||||||||||||
| Jarrell, TX 76537 | ||||||||||||
| Fire Protection Systems • Commercial • Industrial • Institutional • Special Hazards • High Tech • Defense • Hangars • Retrofit • Service • Inspection • Maintenance | Ph: (512) 598-3959 | |||||||||||
| Fax: (512) 598-3961 | ||||||||||||
| TX-SCR-G 1819205 * TX-ACR 1666099 * TX-ECR 1666599 | Date: | April 2017 | ||||||||||
| Report to: | VA Waco Campus | Location or Building Inspected: | Building 91 | |||||||||
| Contact: | R. Griffin | Phone: | Fax: | |||||||||
| Address: | 4800 Memorial Dr. | email: | ||||||||||
| City, State: | Waco, TX | Zip: | 76711 | Inspector: | Dennis Thompson | |||||||
| Page | 1 | of | 4 | |||||||||
| Damper Testing Report Per NFPA 80 and EC.02.03.05 item 18 |
| Location | Damper ID | Notes | Pass/Fail |
| Southeast office | FD-B-001 | no access / can't reach damper | NA |
| Mechanical Room 2B-100 | FD-2-002 | damper did not close | F |
| Mechanical Room 2B-100 | FD-2-006 | no access/access panel too small | N/A |
| Mechanical Room 2A-109C | FD-2-009 | no access/access panel too small | N/A |
| Mechanical Room 2A-109C | FD-2-010 | no access/access panel too small | N/A |
| Attic | FD-A-001 | no access/access panel too small | N/A |
| Attic | FD-A-004 | no access/access panel too small | N/A |
| Attic | FD-A-006 | no access/access panel too small | N/A |
| Attic | FD-A-014 | damper did not close | F |
| ` | FD-A-017 | no access/access panel obstructed | N/A |
| Attic | FD-A-019 | no access/access panel too small | N/A |
| Attic | FD-A-021 | no access/access panel too small | N/A |
| Attic | FD-A-022 | no access/access panel too small | N/A |
| Attic | FD-A-023 | no access/access panel too small | N/A |
| Attic | FD-A-024 | no access/access panel too small | N/A |
| Attic | FD-A-025 | no access/access panel too small | N/A |
| Attic | FD-A-027 | no access/access panel too small | N/A |
| Attic | FD-A-032 | no access/access panel obstructed | N/A |
| Attic | FD-A-034 | no access/access panel too small | N/A |
| Attic | FD-A-037 | no access/access panel too small | N/A |
| Attic | FD-A-038 | no access/access panel too small | N/A |
| Attic | FD-A-039 | no access/access panel too small | N/A |
| Attic | FD-A-043 | no access/access panel too small | N/A |
| Attic | FD-A-044 | no access/access panel too small | N/A |
| Attic | FD-A-045 | no access/access panel too small | N/A |
| Attic | FD-A-046 | no access/access panel too small | N/A |
| Attic | FD-A-047 | no access/access panel too small | N/A |
| Attic | FD-A-049 | no access/access panel too small | N/A |
| Attic | FD-A-050 | no access/access panel too small | N/A |
| Attic | FD-A-051 | no access/access panel too small | N/A |
| Attic | FD-A-052 | no access/access panel too small | N/A |
| Attic | FD-A-053 | no access/access panel too small | N/A |
| Attic | FD-A-054 | no access/access panel too small | N/A |
| Attic | FD-A-055 | no access/access panel too small | N/A |
| Attic | FD-A-056 | no access/access panel too small | N/A |