Riser Locations_M1-M2 West.pdf
PDF 818 KB Posted
- Solicitation number
- 36C25624R0116
About this file
This document appears to be a set of drawings related to a federal contract opportunity. The drawings include details on riser locations, wall elevations, and mechanical equipment for a construction project at the SLVHCS Replacement Medical Center in New Orleans, Louisiana.
The related federal contract opportunity is Solicitation Number 36C25624R0116 for the "Z1DA--CON Project 629-20-102 Expansion of Security Cameras at 2400 Canal St", issued by the Department of Veterans Affairs, Veterans Integrated Service Network 16. The solicitation is for construction services to expand the security camera system at the specified location. Key details about the contract opportunity are not provided in the document reviewed.
View the file
Other files
Show 40 more
Latest 50 of 140 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
06-L1 100' - 0"
06-L2 119' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06 1 06 2 06 3 06 4 06 5 06 6
06-R 173' - 0"
2.3
2.7
3.3
F4
R6AS408
F2
R6AS408
CAST IN PLACE
COLUMN TO MATCH
PRE-CAST FINISH
METAL TERRACE WALL
SG
-0
SG
-0
SG
-0
SG
-0
IG-01 TYP ACROSS C.W.
IG-01 TYP ACROSS C.W.
MP-2
SEC
W.H E.R
E.RW.H
0.9
9'
0"
3'
6"
BK-1A
TYP ACROSS C.W.
SHEAR JT.
SHEAR JT.
STACK JT.
MVMT JT.
STACK JT.
STACK JT.
ROOF SCUPPER
6' - 7" 33' - 0" 13' - 2 3/8" 9' - 10 3/4" 9' - 10 3/4" 9' - 10 3/4" 23' - 1 1/4" 33' - 0" 33' - 0"
SG
-0
MVMT JT.
IG
-0
IG
-0
IG
-0
IG
-0
IG
-0
2"
2'
6"
2" 9'
/2
/2
7'
/2
/2
1'
4"
2" 9'
/2
2'
/2
6'
0"
9'
1/
2" 8'
/2
9'
1/ 2"
8'
0" 1'
8"
2'
7"
3'
9" 1'
4"
1'
4"
1/ 2"
2'
6"
2' - 0"
TYP.
3' - 0"
2'
6"
2' - 0"
SG-01 TYP ACROSS C.W.
9'
9" 7'
2'
6"
2' - 6" 3' - 6" 3' - 6" 2' - 6"
SG
-0
IG
-0
IG
-0
SG
-0
IG
-0
SG
-0
IG
-0
IG
-0
IG
-0
IG
-0
IG
-0
IG
-0
SG
-0
SG
-0
SG
-0
IG
-0
IG
-0
SG
-0
SG
-0
SG
-0
IG
-0
IG
-0
E2
R6AS412
MVMT JT.
HOISTWAY
VENT LOUVER
RTU BEYOND TO BE PAINTED EXTC-1
RTU BEYOND TO BE PAINTED EXTC-1
"MP-2 MECHANICAL SCREEN WALL.
STRUCTURAL SUPPORTS TO BE
ISSUED IN A SEPARATE BULLETIN
06-L1 100' - 0"
06-L2 119' - 0"
STREET
95' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06-R 173' - 0"
F6
R6AS402
F2
R6AS401
F3
R6AS401
F6
R6AS251
F5
R6AS401
F5
R6AS402
F3
R6AS402
F2
R6AS402
F4
R6AS402
CAST IN PLACE COLUMN TO
MATCH PRE-CAST FINISH
METAL TERRACE WALL
9'
0"
MP-2
SEC
E.RW.H
W.H E.R
BK-1A
TYP ACROSS C.W.
SHEAR JT.
SHEAR JT.
STACK JT.
STACK JT.
STACK JT.
STACK JT.
ROOF SCUPPER
5'
0"
2" 9'
/2
/2
7'
/2
/2
1'
4"
2'
7" 1'
8"
8'
0" 6'
1/ 2"
1'
3"
/2
7'
/2
9'
2"
EQEQ
TYP.
3' - 0"
TYP.
3' - 0"
3' - 5 3/8"
1' - 6"
1' - 9 3/4" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 0"
3' - 0"
MVMT JT.
MVMT JT.
RTU BEYOND TO BE
PAINTED EXTC-1
MP-2 MECHANICAL SCREEN WALL.
STRUCTURAL SUPPORTS TO BE
ISSUED IN A SEPARATE BULLETIN
RTU BEYOND TO BE
PAINTED EXTC-1
M1 M2 M3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
R6AS205
BLDG 6 WEST EXTERIOR ELEVATIONS
DMR PJHApril 17, 2013
06629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
COMMUNICATIONS DESIGN GROUP / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_06
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"
BLDG 6 WEST ELEVATION1
SCALE: 1/8" = 1'-0"
BLDG 6 WEST ELEVATION PERPENDICULAR2
2 1
MATERIAL TYPES
GLAZING TYPES
SYMBOLS LEGEND
INSULATED LAMINATED
VISION
INSULATED METAL PANEL (MP-2)
PRECAST
EXTERIOR MATERIALS LEGEND
INSULATED LAMINATED SPANDREL
MECHANICAL LOUVER.
SEE NOTE FOR ACTIVE LOUVER DIM.
O.D OVERFLOW DRAIN (SECONDARY)
O.S OVER FLOW SCUPPER
O M.E.P. FP PENETRATIONS THROUGH
ENCLOSURE
EXIT EXIT LIGHT
STUCCO / E.I.F.S (SEE NOTE ON ELEV.)
METAL PANEL (MP-1)
IG-01 INSULATED LAMINATED VISION
SG-01 INSUL. LAMINATED SPANDREL
BRICK VENEER - STRETCHER BOND
RUNNING 1/3 PATTERN
W.H WALL HYDRANT
E.R ELECTRICAL RECEPTACLE
C.R CARD READER
SEC SECURITY CAMERA
FDC FIRE DEPARTMENT CONNECTION
STD SPRINKLER TEST DRAIN
DIMENSION NOTES
1. ALL DIMENSION STRINGS FROM C/L OF JT. TO C/L OF JT.
EXCEPT AT ENDS OF EXTERIOR WALL & U.N.O.
2. REFER TO PLANS FOR CW. VERT. FRAMING LOCATIONS.
REFER TO ELEVATIONS FOR FRIT PATTERN EXTENT
3. REFER TO PLANS FOR WINDOW LOCATIONS IN METAL
PANEL & PRECAST SYSTEMS. REFER TO ELEVATIONS FOR
LOCATIONS OF JOINTS IN THESE SYSTEMS.
4. REFER TO PLANS FOR MP-2 SYSTEM LOCATIONS WITH
C.M.U BACKUP.
WALL TYPES LEGEND
1. CURTAINWALL: WALL TYPE CW-1 IS TYPICAL U.N.O.
2. RECESSED PANELS AT WALL TYPE PC-2 AS
NOTED ON DRAWINGS - SEE DTL E6/0AS502 FOR
DETAIL AND REFER TO SPECIFICATION FOR FINISH
AT RECESS.
WALL TYPE MARK REFER TO SHEET
0AS501
0AS502
0AS503
0AS504
0AS505
0AS506
0AS507
0AS508
0AS509
PC-1
PC-2
PC-3, CW-1
CW-1C
CW-1D
CW-3
MP-1
MP-2
MP-2A
BRICK VENEER - STACKED ROWLOCK
BOND PATTERN
7 BULLETIN 010D 4/17/2013
11 BULLETIN 010H 7/3/2013
14 BULLETIN 010K 02/28/14
RFI 02176 - Approval of changed curtain wall dimensions per shop drawings in submittal 084413-014.1
RFI 03250: Addresses brick tie spacing at this location
RFI 03250: Addresses brick tie spacing at this location
This sheet has been updated per RFI 04114
RFI 04114 08/08/2014
RTU BEYOND TO BE
1' - 0"
2' - 0"
3' - 0"
2' - 0"
1' - 0"
RFI 4520: Dimensions to Door Beyond
SEC
9'
5"14
RFI 4799
RFI 4799
F3
R6AS401
RFI 4799
RFI 4799
RFI 06139: Provides sill detail for spandrel glass
RFI 06000: Adds metal flashing
RFI 06000: Adds metal flashing
RFI 06030: Mech Screen Wall Deleted
RFI 06030: Mech Screen Wall Deleted
RFI 06724: Damper relocated to exterior and mount with weather hood. Provide NEMA 3R enclosure for actuator. See attached sketch.
RFI 06944: Metal panel to cover exposed grade beam south of site wall
RFI 06944: Metal panel to cover exposed grade beam south of site wall
RFI 08590: Scupper does not receive downspout.
RFI 08590: Scupper does not receive downspout.
File details come from the government source that posted it. Updated .