This document appears to be a set of construction drawings related to a federal contract opportunity. The drawings depict the riser locations and elevations of a building as part of Project 629-20-102 for the expansion of security cameras at 2400 Canal St in New Orleans, Louisiana. The project is solicited under Solicitation Number 36C25624R0116 by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 16. The drawings provide detailed dimensions and specifications for the building's exterior, including insulated laminated vision and spandrel glass, metal panels, precast concrete, and other construction materials and components. The drawings also include notes on wall types, expansion joints, and other relevant details. No information is provided on response dates, award dates, pricing, set asides, or incumbents.
View the file
Other files
Show 40 more
Latest 50 of 140 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
06-L1 100' - 0"
06-L2 119' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06 A06 B06 D06 E06 F
06-R 173' - 0" 2/
6A S2
1 /
6A S2
F3
R6AS406
06 C
F4
R6AS406
CAST IN PLACE COLUMN TO
MATCH PRE-CAST FINISH
30' - 0"30' - 0"30' - 0"
TYP BAY DIMS
30' - 0"30' - 0"
" CW-1
CR
E.R
CR
E.R
2"
1'
1" 9'
1"
1'
6" 8'
1/ 2"
7'
9"
7'
9"
9'
7" 2'
6"
6'
3'
9" 9'
1/ 2"
8'
/2
9'
1/
2" 8'
0" 1'
8"
1'
0" 1'
6"
R6AS253
C5
5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"
3'
6"
SG-01 TYP
TYPIG-01
SG-01
IG-01
SG-01
TYP
TYP
TYP
IG-01 TYP
5' - 3 3/4"6' - 0"5' - 2 7/8"
EJ
STACK JT.
STACK JT.
06-L1 100' - 0"
06-L2 119' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06 G06 H06 J06 K
06-R 173' - 0"
06 L06 M
2/ 6A
S2
1 / 6A
S2
F6
R6AS407
CAST IN PLACE COLUMN TO
MATCH PRE-CAST FINISH
CW-1
BK-1A
2/ 6A
S2
2 / 6A
S2
30' - 0" TYP BAY
2"
1'
1" 9'
1"
1'
6" 8'
1/ 2"
7'
9"
7'
9"
9'
7" 2'
6"
30' - 0"30' - 0"30' - 0"30' - 0"19' - 0"
O.D
0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"
1' - 6" 2' - 7 3/8"
1'
4" 1'
2"
IG-01
SG-01
IG-01
SG-01
TYP
TYP
TYP
TYP
BK-1A
EJEJEJEJ
STACK JT.
STACK JT.
RTU BEYOND TO BE PAINTED EXTC-1
OUTLINE OF EXTERIOR DUCT
M1 M2 M3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
R6AS207
BLDG 6 NORTH EXTERIOR ELEVATION
DMR PJHApril 17, 2013
06629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
COMMUNICATIONS DESIGN GROUP / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_06
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"
BLDG 6 NORTH ELEVATION - AREA M11
SCALE: 1/8" = 1'-0"
BLDG 6 NORTH ELEVATION - AREA M22
1 2
MATERIAL TYPES
GLAZING TYPES
SYMBOLS LEGEND
INSULATED LAMINATED
VISION
INSULATED METAL PANEL (MP-2)
PRECAST
EXTERIOR MATERIALS LEGEND
INSULATED LAMINATED SPANDREL
MECHANICAL LOUVER.
SEE NOTE FOR ACTIVE LOUVER DIM.
O.D OVERFLOW DRAIN (SECONDARY)
O.S OVER FLOW SCUPPER
O M.E.P. FP PENETRATIONS THROUGH
ENCLOSURE
EXIT EXIT LIGHT
STUCCO / E.I.F.S (SEE NOTE ON ELEV.)
METAL PANEL (MP-1)
IG-01 INSULATED LAMINATED VISION
SG-01 INSUL. LAMINATED SPANDREL
BRICK VENEER - STRETCHER BOND
RUNNING 1/3 PATTERN
W.H WALL HYDRANT
E.R ELECTRICAL RECEPTACLE
C.R CARD READER
SEC SECURITY CAMERA
FDC FIRE DEPARTMENT CONNECTION
STD SPRINKLER TEST DRAIN
DIMENSION NOTES
1. ALL DIMENSION STRINGS FROM C/L OF JT. TO C/L OF JT.
EXCEPT AT ENDS OF EXTERIOR WALL & U.N.O.
2. REFER TO PLANS FOR CW. VERT. FRAMING LOCATIONS.
REFER TO ELEVATIONS FOR FRIT PATTERN EXTENT
3. REFER TO PLANS FOR WINDOW LOCATIONS IN METAL
PANEL & PRECAST SYSTEMS. REFER TO ELEVATIONS FOR
LOCATIONS OF JOINTS IN THESE SYSTEMS.
4. REFER TO PLANS FOR MP-2 SYSTEM LOCATIONS WITH
C.M.U BACKUP.
WALL TYPES LEGEND
1. CURTAINWALL: WALL TYPE CW-1 IS TYPICAL U.N.O.
2. RECESSED PANELS AT WALL TYPE PC-2 AS
NOTED ON DRAWINGS - SEE DTL E6/0AS502 FOR
DETAIL AND REFER TO SPECIFICATION FOR FINISH
AT RECESS.
WALL TYPE MARK REFER TO SHEET
0AS501
0AS502
0AS503
0AS504
0AS505
0AS506
0AS507
0AS508
0AS509
PC-1
PC-2
PC-3, CW-1
CW-1C
CW-1D
CW-3
MP-1
MP-2
MP-2A
BRICK VENEER - STACKED ROWLOCK
BOND PATTERN
7 BULLETIN 010D 4/17/2013
11 BULLETIN 010H 7/3/2013
14 BULLETIN 010K 02/28/14
RFI 03124: Clarifies detail of expansion joint
RFI 03124: Clarifies detail of expansion joint
RFI 03938: Added Section Detail
This sheet has been updated per RFI 04114
RFI 04114 08/08/2014
BK-1A
OUTLINE OF EXTERIOR DUCT
RFI 4799
RFI 05875: No flashing required at loose lintel.
RFI 4584: Deletes Card Reader
RFI 07011:
Receptacle Deleted
RFI 8152: Exterior Duct does NOT need to be painted
File details come from the government source that posted it. Updated .