Camera Locations_DNT 2F.pdf
PDF 535 KB Posted
- Solicitation number
- 36C25624R0116
About this file
This document appears to be a floor plan detailing the camera locations within the 2F section of a healthcare facility. It identifies the specific camera numbers and their locations throughout the second floor, including rooms, corridors, and common areas.
The related federal contract opportunity is for the expansion of the security camera system at the 2400 Canal St. location. The solicitation number is 36C25624R0116, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The contract requires the installation of additional security cameras throughout the facility as detailed in the floor plan provided.
View the file
Other files
Show 40 more
Latest 50 of 140 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2AI102-E2
2AI102-F2
CORR
2F-C08
CORR
2F-C04
CORR
2F-C03
CORR
2F-C01
CORR
2F-C09
CORR
2F-C11
CORR
2F-C06
CORR
2F-C07B
STAIR
ELEV
FS-08
ST
P
T/D
T/D
T/DT/D
T/D T/D
DRESS
ULTRASOUND
RADIOLOGY
RADIOLOGY
RADIOLOGY RADIOLOGY R/F R/F
SECY/
WAIT
CHIEF
ASST
CHIEF
RAD
RADIOLOGIST
RADIOLOGIST
RADIOLOGIST
RADIOLOGIST
RADIOLOGIST
CHIEF
TECH
SECTION
CHIEF
PHYSICIST
OFF
COPY
ROOM
PROF
PROF
CHIEF
TECH
SCHED
SCHED
PAT
HOLD
EQUIP
CALIB
(NM)
SECRETARY
STAFF
PHYS
TELE-NM
CONFERENCE
ROOM
BIOSAFETY
LAB
SOILED
LINEN
BONE
DENS
2F132
MEDS
SOILED
QA
QA
DATA
PROCESS
CLERICAL
ST
ST
PACS
ADMIN
TEE
ROOM
BIO-MED
WORK
TEE
RECOVERY
BAY
T/D
DRESS
TEE
SCOPE
HOLD
STAFF
WORK
T
PAT
HOLD
PAT
HOLD
ST
ST
CLEAN
EC
RAD
WASTE
PAT
HOLD
T
SHF15
CONTROL
PAT
HOLD
PAT
HOLD
NURSE
STATION
EXAM
CORR
2F-C10A
RESIDENT
WORK
EC
SHD12
DRESS
DRESS
DRESS
ULTRASOUND
ULTRASOUND
ULTRASOUND
RADIOLOGY
WORK
AREA
ULTRASOUND
RADIOLOGY
T/D
2F110
DRESS
T/D
DRESS
CORR
2F-C02
DRESS
DRESS
DRESS
DRESS
DRESS
DRESS
DRESS
ALC
2F100A
STST
CORR
2F-C16
STAIR
2F153
WORK
CR
CR
CR
CR
CR
H V
C
H V
C
FEC
DP
DP
F E
C
CORR
2F-C05
DP
DP
FEW
F E
C
F E
C
F E
C
EXTERIOR
DP
UP
DN
DN
UP
UPUP
SERVICE
BAY
SERV
ELEV
LOBBY
TELECOM
BONE
DENS
EMER
ELEC
NORM
ELEC
EC
SHAFT
SHF10
SECURITY
T/D
CONFERENCE
ROOM
T/D
ALC
ALC
ALC
STAIR
CRCR
FEC
DP
SHAFT
SHF08
HVC
STP
STORAGE
FEW
F E
C
SHAFT
SHF04
RECEPTION
OPEN
TO
BELOW
DP
2F124 2F120 2F116 2F112
2F100
2F110
2F114
2F118
2F122
2F126
2F125
2F123
2F121
2F119
2F117
2F115
2F130A 2F130B
2F113
2F111
2F131
2F133
2F131A
2F135
2F130
2F139
2F137
2F144
2F140
2F148
2F142
2F146 2F154
2F152
2F150
2F101
2F105
2F103
2F107A 2F107B
2F105B
2F105A
2F107
2F317
2F222
2F220
2F221
2F219
2F218 2F216
2F210
2F2122F214
2F224
2F226
2F200.3
2F200.5
2F200.1
2F228
2F230 2F232
2F234
2F231
2F308
2F211
2F202
2F204
2F200.2
2F315
2F313
2F311
2F309
2F307
2F305
2F303
2F301
2F306
2F304
2F236
2F238
2F244
2F246
2F248
2F242
2F239
2F237
2F235
2F240
2F240A
2F240B
2F240D
2F240C
2F240E
2F240F
2F240G
2F240H
2F240K
2F240J
2F153
2F155
2F149
2F151
2F160
2F147
2F145
2F143
2F141
2F317A
2F317B
2F317C
2F100A
2F103A
2F103B
CUBICLES
AREA
2F200
ELEV
FP-05
ELEV
FP-04
ELEV
FP-03
ELEV
FS-06
ELEV
FS-07
STAIR
T/D
THYROID
UPTAKE
CC
HK
T
LINEN
FEC
2G310A
2F247
2F245
2G223
2G224
2G222A
CORR
2F-C07B2
CORR
2F-C07B1
2F-C03.3
CORR
2F-C03A
CORR
2F-C01A
PUB
ELEV
LOBBY
2A200A1
HOLDING
AREA
2C214
2C215
2C213
2C216
2C222
2C223
2C215 2C215
2C215
2C215
2C215
2C215
2C215 2C215
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2
M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2
R3
A3
DNT LEVEL 2F
2C222 SOILED LINEN 2F315
2C223 TR 2F105B
SECURITY CAMERA COUNT SECOND FLOOR AREA-F
CAMERA NUMBER INSTANCE COMMENT
2C213 CORRIDOR 2F-C08
2C214 STAIR STF-04
2C215 STAIR STF-02
2C216 PUBLIC ELEVATOR LOBBY 2A200A1
NOTES:
1. ALL SECURITY DEVICES ON THIS PLAN SHALL BE
WIRED TO LVSR 2F227B.
| Sheets and Views |
| DNT-2AI102-F2-CLEANED-Layout2 |
File details come from the government source that posted it. Updated .