Riser Locations_M1-M2 South.pdf
PDF 764 KB Posted
- Solicitation number
- 36C25624R0116
About this file
This document appears to be a set of construction drawings for Riser Locations related to the M1-M2 South sections of Building 6 for the SLVHCS Replacement Medical Center Project in New Orleans, Louisiana. The drawings provide detailed information on the location and dimensions of various building components such as insulated laminated vision and spandrel glazing, metal panels, brick veneer, and mechanical equipment. The drawings also reference several Request for Information (RFI) documents that have been incorporated, including details on louvers, movement joints, brick ledges, and overflow drains. This document does not appear to contain specific information about a federal contract opportunity. It is focused on the construction details for this building project.
View the file
Other files
Show 40 more
Latest 50 of 140 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
06-L1 100' - 0"
06-L2 119' - 0"
STREET
95' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06 A 06 B 06 D 06 E 06 F
06-R 173' - 0"
C6
R6AS407
1/ 6A
S2
2 / 6A
S2 0606 C
C5
R6AS407
C4
R6AS407
B6
R6AS410
B5
R6AS410
METAL TERRACE WALL
5'
0" 8 3/4"
MP-2
BK-1A
SEC
CONTRACTOR TO PROVIDE
ROUGH-IN FOR LIGHT
FIXTURE AT METAL PANEL
WALL BEYOND (TYP.)
O.D
O.D
O.D
O.D
O.D
O.D
2'
6"
4'
/2
3'
7" 7'
9"
1'
2" 1'
4"
7'
4"
1'
4"
7'
/2
1'
1/
2" 1'
4"
6'
0"
1'
4"
7'
1/
2"
3'
1/
2" 1'
4"
2'
0"
E.R
30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"
O.D
O.D
O.D
O.D
SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01
IG-01 IG-01 SG-01 SG-01 SG-01 SG-01 IG-01 SG-01
SG-01 SG-01 SG-01
IG-01 IG-01 IG-01 IG-01
SG-01 SG-01 SG-01
IG-01 IG-01 SG-01
SG-01 SG-01
6' - 0"
TYP.
3' - 0"
SG-01 SG-01 SG-01 SG-01
IG-01 IG-01 SG-01 SG-01 SG-01 SG-01
SG-01
SG-01 IG-01 SG-01
SG-01
SG-01 SG-01
IG-01
SG-01
SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01
SG-01
SG-01SG-01IG-01
IG-01
IG-01IG-01
IG-01
IG-01SG-01SG-01SG-01SG-01
IG-01IG-01IG-01IG-01IG-01
SG-01 SG-01 SG-01 SG-01
C2
R6AS407
IG-01IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01
MVMT JT
EJ
MVMT JT
EJ EJ EJ EJ EJ
EQEQ
1' - 6"
06-L1 100' - 0"
06-L2 119' - 0"
STREET
95' - 0"
06-L3 137' - 0"
06-L4 155' - 0"
06 G 06 H 06 J 06 K
06-R 173' - 0"
06 L 06 M
1/ 6A
S2
2 / 6A
S2
2 / 6A
S2
1 / 6A
S2
F4
R6AS407
FDC
5'
0"
9'
0" 1'
2"
1'
4"
1'
4"
TYP.
3' - 0"
MP-2BK-1A
BK-1A
SEC
O.D
O.D
O.D
O.D
MP-2
2'
6" 4'
/2
3'
7"
7'
9" 1'
2"
1'
4" 7'
4"
1'
4" 7'
/2
1'
1/
2"
7'
4" 1'
4"
7'
1/
2"
3'
1/
2"
1'
4"
2'
0"
1'
4"
1'
4"
7'
7"
1'
2"
8'
1'
4"
EJ EJ EJ EJ EJ
30' - 0" 30' - 0" 30' - 0" 30' - 0" 19' - 0"
ROOF SCUPPER
O.D
O.D
O.D
O.D
SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01 SG-01
SG-01SG-01IG-01IG-01IG-01IG-01IG-01IG-01IG-01IG-01IG-01IG-01IG-01SG-01
SG-01
SG-01
SG-01 SG-01 SG-01
SG-01 SG-01 SG-01 SG-01 SG-01 IG-01
IG-01
IG-01SG-01 SG-01
IG-01
IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 SG-01 SG-01
SG-01
TYP.
3' - 0"
EQEQ
IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01 IG-01IG-01 IG-01 IG-01 IG-01 IG-01
3"
1'
2" 1'
4"
F4
R6AS410
EJ EJ EJ
MVMT JT
MVMT JT
MVMT JT
MVMT JT
EJ
MVMT JT
MVMT JT.
MP-2 MECHANICAL SCREEN WALL.
STRUCTURAL SUPPORTS TO BE
ISSUED IN A SEPARATE BULLETIN
OUTLINE OF EXTERIOR DUCT
EJ
EQEQ
1' - 6"
3' - 0"
M1 M2 M3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
R6AS206
BLDG 6 SOUTH EXTERIOR ELEVATION
DMR PJHApril 17, 2013
06629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
COMMUNICATIONS DESIGN GROUP / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_06
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"
BLDG 6 SOUTH ELEVATION - AREA M11
SCALE: 1/8" = 1'-0"
BLDG 6 SOUTH ELEVATION - AREA M22
1 2
MATERIAL TYPES
GLAZING TYPES
SYMBOLS LEGEND
INSULATED LAMINATED
VISION
INSULATED METAL PANEL (MP-2)
PRECAST
EXTERIOR MATERIALS LEGEND
INSULATED LAMINATED SPANDREL
MECHANICAL LOUVER.
SEE NOTE FOR ACTIVE LOUVER DIM.
O.D OVERFLOW DRAIN (SECONDARY)
O.S OVER FLOW SCUPPER
O M.E.P. FP PENETRATIONS THROUGH
ENCLOSURE
EXIT EXIT LIGHT
STUCCO / E.I.F.S (SEE NOTE ON ELEV.)
METAL PANEL (MP-1)
IG-01 INSULATED LAMINATED VISION
SG-01 INSUL. LAMINATED SPANDREL
BRICK VENEER - STRETCHER BOND
RUNNING 1/3 PATTERN
W.H WALL HYDRANT
E.R ELECTRICAL RECEPTACLE
C.R CARD READER
SEC SECURITY CAMERA
FDC FIRE DEPARTMENT CONNECTION
STD SPRINKLER TEST DRAIN
DIMENSION NOTES
1. ALL DIMENSION STRINGS FROM C/L OF JT. TO C/L OF JT.
EXCEPT AT ENDS OF EXTERIOR WALL & U.N.O.
2. REFER TO PLANS FOR CW. VERT. FRAMING LOCATIONS.
REFER TO ELEVATIONS FOR FRIT PATTERN EXTENT
3. REFER TO PLANS FOR WINDOW LOCATIONS IN METAL
PANEL & PRECAST SYSTEMS. REFER TO ELEVATIONS FOR
LOCATIONS OF JOINTS IN THESE SYSTEMS.
4. REFER TO PLANS FOR MP-2 SYSTEM LOCATIONS WITH
C.M.U BACKUP.
WALL TYPES LEGEND
1. CURTAINWALL: WALL TYPE CW-1 IS TYPICAL U.N.O.
2. RECESSED PANELS AT WALL TYPE PC-2 AS
NOTED ON DRAWINGS - SEE DTL E6/0AS502 FOR
DETAIL AND REFER TO SPECIFICATION FOR FINISH
AT RECESS.
WALL TYPE MARK REFER TO SHEET
0AS501
0AS502
0AS503
0AS504
0AS505
0AS506
0AS507
0AS508
0AS509
PC-1
PC-2
PC-3, CW-1
CW-1C
CW-1D
CW-3
MP-1
MP-2
MP-2A
BRICK VENEER - STACKED ROWLOCK
BOND PATTERN
7 BULLETIN 010D 4/17/2013
11 BULLETIN 010H 7/3/2013
14 BULLETIN 010K 02/28/14
6" 6" 6" 6" 6"
10"10" 10"
10"10"10"
6"
6" 6" 6" 6"
RFI 4442
O.D
O.D
RFI 4442
RFI 4442
RFI 4442
RFI 4442
RFI 4442 RFI 4442
RFI 4442
RFI 4442
O.D
RFI 02896.1: Provides head, jamb, and sill detail at louver
RFI 03075: Relocates horizontal movement joints east of K line and vertical joint west of K line.
RFI 03115: Clarifies pilaster detail at brick ledge RFI 03115: Clarifies pilaster detail at brick ledge
RFI 03115: Clarifies pilaster detail at brick ledge
RFI 03124: Clarifies detail of expansion joint
RFI 03282: Provides typical section of overflow drain in brick
RFI 03282: Provides typical section of overflow drain in brick
This sheet has been updated per RFI 04114
RFI 04114 08/08/2014
RFI
03124
RFI
03124RFI
03124
RFI
03124RFI
03124
RFI
03124
RFI 03124 RFI
03124
RFI
03124
RFI 4442RFI 4442
RFI 4442
RFI 4442
RFI 4442
RFI 4442 RFI 4442
RFI 4442
RFI 4442
RFI 4442RFI 4442
RFI 4442
RFI 4799
RFI 05860: Elevation of brick shelf changed to 96'-8". Slope away from the brick veneer at 1/4":1'-0". Approximately 1-3/8" to 2" of non-shrink grout to be used on top of current brick ledge.
RFI 05860: Elevation of brick shelf changed to 96'-8". Slope away from the brick veneer at 1/4":1'-0". Approximately 1-3/8" to 2" of non-shrink grout to be used on top of current brick ledge.
RFI 06083: Extends horizontal brick shelf
RFI 06000: Adds sheet metal flashing
RFI 06030: Screen Wall Deleted
RFI 06116: No FDC required at this location.
RFI 06278: Relocates control joint farther west
RFI 07116: Clarifies door and sealant color
File details come from the government source that posted it. Updated .