FY 2024 Annual Fire Alarm Bldg 9.pdf
PDF 13 MB Posted
- Attached to
- H312--502-Fire Alarm / sprinkler Service Contract (VA-24-00082860) 502-24-3-5048-0215/36C256-24-AP-3612
- Solicitation number
- 36C25624Q1010
About this file
This document is a Request for Quote (RFQ) for a Fire Alarm and Sprinkler Service Contract at a Department of Veterans Affairs (VA) facility. The solicitation seeks quotes for annual fire alarm and sprinkler system testing and maintenance services.
Key requirements include: 1) The contractor must be certified as an authorized "Fire Works" Edwards Systems Technology repair company and EST 3 dealer, with NICET Level I or higher technicians and a NICET Level 3 or higher supervisor; 2) The contractor must have at least 3 years' experience installing EST-3 networks and demonstrate the ability to respond to emergencies within 1 hour; 3) The contractor must be certified with the Louisiana State Fire Marshal, hold a NICET Level 3 or higher certification for sprinkler system inspection and testing, and have a minimum 3 years' experience in sprinkler system installation and maintenance. Quotes must provide pricing for all required fire alarm and sprinkler work. The RFQ has a response deadline of June 27th, 3:00pm CST. Award will be made to the lowest priced, technically acceptable offer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25624Q1010 0002.docx | DOCX document | |
| Fire Alarm Questions and Answers part 2.docx | DOCX document | |
| FY 2024 Annual Fire Alarm Bldg 45.pdf | ||
| FY 2024 Annual Fire Alarm Bldg 7.pdf | ||
| 36C25624Q1010 0001.docx | DOCX document | |
| FY 2024 Outer buildings Annual Fire Alarm Test_Redacted.pdf | ||
| 11101 VA Fire Det Drawings.pdf | ||
| 36C25624Q1010_1.docx | DOCX document | |
| Wage Determination 2015-5175.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Inspection and Test Report
Date: October 16, 2023 Time: 8:00am Tag Color: Green
Service Organization Location
Name: Alexandria VA Fire Department Customer: Building 9
Address: 2495 Shreveport Hwy Property: Alexandria VA Health Care System
Pineville, LA
ZIP Code 71360
Monitoring Company
Contact: Alexandria VA Fire Department
Telephone: 318-466-2718
Transmission Type
Address: 2495 Shreveport Hwy
Pineville, LA 71360
Contact: Joel Miller Fire Chief
Telephone: (318) 466-4313
Service Frequency
McCulloh Weekly
Multiplex Monthly
X Digital Quarterly
Reverse Polarity Semi-Annual
RF X Annual
Other: Other:
Control Panel Manufacturer: Edwards (ETS)
Number of Initiating Circuits: 2 (A & B)
Software Version Number: V4.0
Last Date System Had Any Service Performed:
Model No.: Fire Work System
Circuit Styles A & B Fiber
Last Date Software or Configuration Was Change(
Alarm Initiating Device and Circuit Information
Quantity Quantity Circuit Installed Tested Styles Device Type
18 18 2 Manual Pull Station
Air Sampling Smoke Detector
Ionization Smoke Detector 27 27 2 Photoelectric Smoke Detector
Photoelectric Beam Detector
Ionization Air Duct Smoke Detector
Photoelectric Air Duct Smoke Detector
Fixed Temperature Heat Detector
2 2 2 Rate of Rise Heat Detector
Rate Compensated Heat Detector
Line Type Heat Detection Cable
7 7 2 Fire Sprinkler Waterflow Switch
Other:
Alarm Verification feature is DISABLED 0 ENABLED 0
Alarm Notification Appliances and Circuit Information
Quantity Quantity Circuit Installed Tested Styles Device Type
0 Bells
0 Horns
0 Chimes
0 Speakers
0 Strobe Lights
125 125 Y Other: Combination Horn/Strobe
Number of Alarm Indicating Circuits: 6
Are Circuits Monitored for Integrity? X Yes No
Supervisory Signal Initiating Devices and Circuit Information
Quantity Quantity Circuit Installed Tested Styles Device Type
13 13 2 Tamper Switch
Building Temperature
Site Water Level
2 2 2 Fire Pump Power
1 1 2 Fire Pump Running
Fire Pump Auto Position
Fire Pump or Controller Trouble
7 7 2 Main Drain
4 4 Fire Department Connections
9 9 2 Transfer Switch/Control Relays
Generator Engine Running
Low Air Pressure
12 12 2 Air Duct Smoke Detector
Other:
Signaling Line Circuits
Quantity: 1 Circuit Style: 6
System Power Supplies a.Primary: Nominal Voltage 120 Amps 1
Overcurrent Protection: Type: Circuit Breaker Amps 20
Location of Primary Supply Panelboard: Elec Closet Room 122B Panel "E9GN"
Power Disconnect Location: Breaker #16 & 18 b.Secondary (Standby)
Sealed Lead Acid Storage Battery: Amp- Hour Rating: 8 AH
Calculated capacity is Amp-Hours to operate the system for 24 Hours
Engine driven generator dedicated to the fire alarm system
Location of fuel storage:
Battery Type
Dry Cell Lead Acid
Nickel- Cadmium Other:
X Sealed Lead Acid
c. Emergency or standby system used as a backup to primary power supply instead of using a secondary power supply:
Emergency system described in NFPA 70, Article 700
Legally required standby system described in NFPA 70, Article 701
Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701
PRIOR TO ANY TESTING
NOTIFICATIONS ARE MADE:
Monitoring Company
Building Occupants
Building Management
Other
AHJ Notified of Any Impairments
Yes x x x
No Who & Time
VA Fire Department 1332
Joel Miller Fire Chief
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Panel
Interface Equipment
Lamp / LED's
Fuses
Primary Power Supply
Trouble Signals
Disconnect Switches
Ground Fault Monitoring
-iC x x x x
SECONDARY POWER
Battery Condition
Load Voltage
Discharge Test
Charger Test
N
See battery calc sheet for size requirements
Specific Gravity
X
TRANSIENT SUPPRESSORS
REMOTE ANNUNCIATORS
NOTIFICATION APPLIANCES
Audible
Visual
X _
Speakers
N/A
Voice Clarity
N/A
INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS
See attached initiating and supervisory device test report
Visual Device
Operation Simulated Operation
COMBINATION SYSTEMS
Time: 12:00 AM
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS
Name of Inspector: Date: 16-Oct-23
EMERGENCY COMMUNICATIONS EQUIPMENT
Phone Set
Phone Jacks
Off-Hook Indicator
Amplifier(s)
Tone Generator(s)
Call-in Signal
System Performance
Functional Comments
INTERFACE EQUIPMENT
SPECIAL HAZARD SYSTEMS
Special Procedures
Comments:
SUPERVISING STATION MONITORING
Alarm Signal
Alarm Restoration
Trouble Signal
Trouble Restoration
Supervisory Signal
Supervisory Restoration
NOTIFICATION THAT TESTING IS COMPLETE
Building Management
Monitoring Company
Building Occupants
Other
Yes
No Time Comments
X
Yes
X
No
Who
Joel Miller Fire Chief
Time
Alexandria VA Fire Departmer
The following did not operate correctly:
System restored to normal operation: Date: 16-Oct-23 Time:
Signature:
Name of Owner or Representative: Joel Miller Fire Chief Date: 16-Oct-23 Time: 12:00 AM
Signature:
Visual
Fire Extinguisher Monitoring Device! System
Carbon Monoxide Detector / System
Other:
Protected Property: Alexandria VA Health Care System Address: 2495 Shreveport Hwy
Date: October 16, 2023 City: Pineville
State: Louisiana Zip 71360
Amps X 24 Hours
- Standby Amp-Hours
I
Amps X 0.083 5 Minutes 24 4 (5/60)
Alarm Amp-Hours
Secondary Standby Load
The Amount of Power that must be Supplied by the Batteries During Non- Alarm Conditions
Secondary Alarm Load
The Amount of Power that must be Supplied by the Batteries During Alarm Conditions
Battery Load Calculations 10/16/2023
Bldg 9 2495 Shreveport Hwy Pineville, LA 71360
Fire Detection
Total Secondary Load
Compensation for Non-Linear Discharge Characteristics X 1.20 Total Ampere Hour Battery Supply Required
Note: The loads shown above were determined by use of a current meter using actual field conditions.
Battery life tests 10/16/2023
Batteries Main Panel Batteries
Left
Right disposition volts
Amps volts
Amps 8Ah 12.7
11Ah 12.64
12Ah Good
Impairments 10/16/2023
Supervisory Signals 10/16/23 10/16/23
ANNUAL
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
EC .02.03.05 EP 1 Joint Commision Environment Of Care Detail Report-
Inspections Performed By Veterans Adminstation Fire Department (VAFD)
F r rir The Joint Commission
VA Fire Department
EC .02.03.05 EP 1
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Date Tested Device Type Building Floor Location Zone No. Notes Performed Result me o Alarm
Notification
I IA 1 st Fire Pump House AC Failure Tested Passed 5 Seconds
I IA 1st Fire Pump House Pump Running Tested Passed 5 Seconds
I IA 1st Fire Pump House
Phase Reversal Tested Passed 5 Seconds
Supervisory Signals
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended Frequency/Type of Inspection Total Devices In Inventory ir The Joint Commission
VA Fire Department Duct bct,ciors (DM»
EC .02.03.05 EP 3 & 19
ANNUAI, NFPA Standards NFPA 72, 2021
NFPA 72, 2010
Joint Commision Environment Of Care Detail Report- EC .02.03.05 EP 3 & 19
Test Result
Duct Detectors (DSD)
Date Tested Device Type Building Cust
Floor Location Zone No.
Comments
Notes Service
Performed 10/16/23 DSD 9 1st AHU Duct Detector Room 134 43020014
Tested Passed 10/16/23 DSD 9 1st AHU Duct Detector Room 124 43020015
10/16/23 DSD 9 2nd AHU Duct Detector Room 218 43020016
10/16/23 DSD 9 2nd AHU Duct Detector Room 202 43020017
10/16/23 DSD 9 2nd AHU Duct Detector Room 201 43020018
10/16/23 DSD 9 2nd AHU Duct Detector Room 201 43020019
10/16/23 DSD 9 3rd Center AHU Duct Detector RM 315 43020024
10/16/23 DSD 9 3rd Center AHU Duct Detector in Lobby 43020026
10/16/23 DSD 9 Attic North AHU Duct Detector AC1 43020020
10/16/23 DSD 9 Attic North AHU Duct Detector AC3 Supply 43020021
10/16/23 DSD 9 Attic Center AHU Cuct Detector AC3 Return 43020022
10/16/23 DSD 9 Attic South AHU AHU Duct Detector AC3 43020023 rpyr VP The Joint Commission
Facility Name Builtling 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Smoke Deteciors IPSD)
10/16/23 10/16/23
ANNUAL
EC .02.03.05 EP 3
NFPA Standards NFPA 72, 2021
NFPA 72, 2010
Joint Commision Environment Of Care Detail Report- EC .02.03.05 EP 3
Date Tested Device Type Building
Smoke Floor
Detectors PSD
Cust Zone No.
Comments
Notes Service
Performed Test
Result Location 10/16/23 PSD 9 1st Coorodor above FACP 43020001
10/16/23 PSD 9 1st Center Elveator Lobby 43020002
10/16/23 PSD 9 1st Center Door by Cooridor RM 135 43020003
10/16/23 PSD 9 1st North Door by RM 134 43020004
10/16/23 PSD 9 1st BLD 9 FL1 CENTER AHU DUCT DET IN ROOM 134 43020014
10/16/23 PSD 9 1st BLD 9 FL1 CENTER AHU DUCT DET OFFICE 124 43020015
10/16/23 PSD 9 1st Center in IRM Closet RM 119 43020029
10/16/23 PSD 9 2nd Center Elevator Lobby 43020006
10/16/23 PSD 9 2nd Center by RM 218 43020007
10/16/23 PSD 9 2nd North By RM 217 43020008
10/16/23 PSD 9 2nd BLD 9 FL2 CENTER AHU DUCT DET IN ROOM 218 43020016
10/16/23 PSD 9 2nd BLD 9 FL2 CENTER AHU DUCT DET IN ROOM 202 43020017
10/16/23 PSD 9 2nd BLD 9 FL2 NORTH AHU DUCT DET IN ROOM 201 43020018
10/16/23 PSD 9 2nd BLD 9 FL2 NORTH AHU DUCT DET IN ROOM 201 43020019
10/16/23 PSD 9 2nd Center by Med RM 200A 43020027
10/16/23 PSD 9 2nd Center in IRM Closet RM 219 43020030
10/16/23 PSD 9 3rd Center Elevator Lobby 43020009
10/16/23 PSD 9 3rd Center by RM 315 43020010
10/16/23 PSD 9 3rd North By RM 314 43020011
10/16/23 PSD 9 3rd BLD 9 FL3 CENTER AHU DUCT DET IN ROOM 315 43020024
10/16/23 PSD 9 3rd Center by Med RM 300A 43020028
10/16/23 PSD 9 3rd Center in IRM Closet RM 316 43020031
10/16/23 PSD 9 Attic Attic Center Top of Shaft 43020013
10/16/23 PSD 9 Attic BLD 9 ATTIC NORTH AHUDUCT DET ON UNIT AC1 43020020
10/16/23 PSD 9 Attic BLD 9 ATTIC CENTR AHUDUCT DET AC3 SUPPLY 43020021
10/16/23 PSD 9 Attic BLD 9 ATTIC CENTR AHUDUCT DET AC3 RETURN 43020022
10/16/23 PSD 9 Attic BLD 9 ATTIC SOUTH AHUDUCT DET AC2 43020023
Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection
Pull Stations
The Joint Commission
ANNUAL
NFPA Standards NFPA 72, 2021
Ref NFPA 72, 2010 It
Joint Commision Environment Of Care Detail Report-
Date Tested Device Type Building Floor
Cust Zone No.
Comments Notes
Service Performed
Test
10/16/23 PS 9 1st Center by RM 127 43020139
10/16/23 PS 9 1st North by RM 112 43020144
10/16/23 PS 9 1st By stairwell 1 43020145
10/16/23 PS 9 1st By RM 122 Exit 43020146
10/16/23 PS 9 1st Cooridor by FACP 43020147
10/16/23 PS 9 1st By stairwell #2 43020148
10/16/23 PS 9 1st Cooridor By RM 134 43020149
10/16/23 PS 9 1st By Stairwell #3 43020150
10/16/23 PS 9 1st By RM 118 Exit 43020151
10/16/23 PS 9 1st South Stairwell #1 43020152
10/16/23 PS 9 2nd Center by waiting room 43020128
10/16/23 PS 9 2nd Center By Stairwell #2 43020154
10/16/23 PS 9 2nd North By Stairwell #3 43020155
10/16/23 PS 9 3rd South By Stairwell #1 43020156
10/16/23 PS 9 3rd Center By stairwell #2 43020157
10/16/23 PS 9 3rd Cooridor By RM 314 43020158
10/16/23 PS 9 3rd North By Stairwell #3 43020159
10/16/23 PS 9 Attic By stairwell #2 43020160
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Inspections Performed By Veterans Adminstation Fire Department (VAFD) rr The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection
Control Relays
Date Tested Device Type
Joint
Building
Commision
Floor
Environment Of Care Detail Report-
Control Relays
EC .02.03.05
Cust Zone No.
EP 3
Comments Notes
Service Performed
Test
10/16/23 CR 9 1st BLD 9 FL1 CENTER SMOKE DOOR HOLDER RLY 43020127
10/16/23 CR 9 1st BLD 9 FL1 CENTER RLY FOR DOOR RELEASE 43020188
10/16/23 CR 9 2nd BLD 9 FL2 CENTER RLY AT LOBBY SMOKE DOORS 43020132
10/16/23 CR 9 2nd BLD 9 FL2 CENTER RLY2AT LOBBY SMOKE DOORS 43020133
10/16/23 CR 9 2nd BLD 9 FL2 CENTER RLY FOR DOOR RELEASE 43020189
10/16/23 CR 9 3rd BLD 9 FL3 CENTER SMOKE DOOR HOLDER RLY 43020136
10/16/23 CR 9 3rd BLD 9 FL3 CENTER RLY FOR DOOR RELEASE 43020190
10/16/23 CR 9 Attic BLD 9 ATTIC CENTER AHU SHTDWN UNIT AC3 43020140
10/16/23 CR 9 Attic BLD 9 ATTIC SOUTH AHU SHTDWN UNIT AC2 43020141 r The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Strobes/ Speaker Strobes
10/16/23 10/16/23
ANNUAL _
NFPA Standards NFPA 72, 2021
Joint Commision Environment Of Care Detail Report- EC .02.03.05 EP 3
Building
Strobes/ Speaker Strobes Cust
Zone No.
Comments
Notes Service
Performed Test
Result Date Tested Device Type Floor Location 10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 111
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST OUTSIDE ROOM 113
YJULt-Illtla
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 114
-1GLILIVJ
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 110
...t.A.A.P-1.
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST CORRIDOR
YOl./LL/A.A./.-/
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST OUTSIDE ROOM 115A
..-VA.A.A.I
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST OUTSIDE ROOM 115D
.-1,,./Ll/l/l.//
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST OUTSIDE WEST STAIRWELL
Y.-A./at-ILA-KJ
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 116
YJVGLILIVJ
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST MALE STAFF LOCKER ROOM
Y.-A-ICI-MIL/ I 1./
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST MALE STAFF LOCKER BATHROOM
Y.-A./LI/VI./ I I
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST MALE STAFF LOCKER BATHROOM
../l/Ll/l/l/ I L
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 117
YJn.,,J I J
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST FEMALE STAFF LOCKER ROOM
Yi....-/l/
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST FEMALE STAFF LOCKER BATHROOM
4,-Illalltll/ I J
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST FEMALE STAFF LOCKER BATHROOM
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 108
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST OUTSIDE ROOM 108
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 118
,JUGLIIN I ../
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 107
Y.-P./Lk/LK/4,J
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 105
YJLIGLAJJC- I
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM G121A
,•./l/Ll/lIl-/LL
10/16/23 SO/SV 9 1st BLD 9 FL1 WEST ROOM 120
VOL/Lill/L/C,/
,,./l/Ll /C/C/L, 10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER ROOM 104
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER ROOM 101
Y.../WLVV,./L /
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER OUTSIDE ROOM 101
,JUGUIJULLI
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER ELEVATOR LOBBY
,JULLIVVJU
,JULVillIJ I
,,,./t-,../L
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER VISITOR WAITING AREA
.1 Jt. IGLIVVJJ
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER ROOM G122
YOVLVVV,P -1'
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER ROOM G122
,JLILLIAJLIJJ
10/16/23 SO/SV 9 1st BLD 9 FL1 CENTER NORTH STAIRWELL
,J,ILI.Illl1,11-1
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST OUTSIDE ROOM 134
4,../l/Li/l/l/t-f I
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 124A
,, ./l/011
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 124B
',Al C-VVVJJ
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 124E
•-1,./l/Gl/l/I,tl/ prov The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Strobes/ Speaker Strobes
10/16/23 10/16/23
ANNUAL
NFPA Standards NFPA 72, 2021
Strobes/ Floor
Speaker Strobes Cust
Zone No.
Comments
Notes Service
Performed Test
Result Location 10/16/23 SO/SV 9 1st BLD 9 FL1 EAST OUTSIDE ROOM 131
.-1,./VGVVVY I
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST OUTSIDE ROOM 129
YJN.Ial.IVVY a
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 127
, A, lalIlll,l, 10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 128
YJVLVVVY,
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST LOBBY AREA 126
.-1,1V.VVVY,
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 125
. ..A./4. VVVYV
.-..JVL V UV, /
•-,..),./LVVVYU
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 125C
. ..A. I all lll,l, 10/16/23 SO/SV 9 1st BLD 9 FL1 EAST ROOM 125B
.-1,1V.VVVJV
10/16/23 SO/SV 9 1st BLD 9 FL1 EAST STAIRWELL
, OW-LA./V..1 I
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST STAIRWELL
.-1, ..1.- I a
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST WING HALLWAY
.1,1,JalJi-lt-10.-1
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST WING HALLWAY
'YOU CUL, I ...I,
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 232
.-..1t. I all,..,10.-1
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 232
•-h-JVC.VVV../V
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 232A
Y.-1,,,JVV../ /
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST OUTSIDE ROOM 222
YJULLA.A.I.Ill
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 233
,•-, all1.11. I ...I J
YJVal-ILIVIJLI
YOlIGLIA-1,11-1, 10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 234
YOWLVV1-1‘.1,
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST ROOM 221
VOL) alll1,J.J
10/16/23 SO/SV 9 2nd BLD 9 FL2 WEST OUTSIDE ROOM 220
YJVal.A.A.11.), 10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER WING HALLWAY
4,211-lallt,./VJ
YIJVC.VVVVU
,Jllalll-n-Ill I
Y011al),,,Ill
10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER ROOM 236
',JUGlltIlll.1, 10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER ROOM 243 BATHROOM
.1,..fULVV,./ 1 tl
10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER ROOM 243 BATHROOM
.....VVV I I
10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER ROOM 240
Y011all,..,11 a
10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER NURSES STATION
.-1,,-,WA., I ...I
. 1,-1,- I alli-Ill I .-1.
- 1,.1,1allA.Illl J
10/16/23 SO/SV 9 2nd BLD 9 FL2 CENTER CORRIDOR AREA
.-1,- ./ 1 V
-ILILI-Ilnl I I
.-1,,Jallilll I 1-1
10/16/23 SO/SV 9 2nd BLD 9 FL2 EAST HALLWAY
4,..0.1,VVV UV
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Inspections Performed By Veterans Adminstation Fire Department (VAFD)
-Jr The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Strobes/ Speaker Strobes
10/16/23
10/16/23
ANNUAL
Strobes/ , '. •,.. ,. ^ v. , . t-- -., •., . , ..-. .--,., , . • ... ..._. ............., Speaker Strobes
Cust Zone No.
Comments Notes
Service Performed
Test
Date Tested Device Type Building Floor Location
- ,....1.,,Illt.1 I
10/16/23 SO/SV 9 2nd BLD 9 FL2 EAST ROOM 206
VOL/al./UV, 10/16/23 SO/SV 9 2nd BLD 9 FL2 EAST ROOM 207
.-1,JULA.IllULI, 10/16/23 SO/SV 9 2nd BLD 9 FL2 EAST ROOM 207
,01....GLIUXII.I,
10/16/23 SO/SV 9 2nd BLD 9 FL2 EAST STAIRWELL
9,-1,-llIlla
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST STAIRWELL
YJVal/VVIJI., 10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST WING HALLWAY
.-1.,,aLllt-Illl! I
,,JW.L.A.PalllJtJ
...Ill a
•-,),C.l.IlllIall
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 321
.1,-Pa LLIAll I a , 10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 327
YOULLIVLIJG
, AJLIGLIlll/ JO
Y•ll. ..1a, 10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 326
•- hal1L.LIVIla a
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 328
.-..IllL.LIldllaiJ
.1....I ,J,Ja I
Vs..". J GUI., all
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 329
,all.alltalla a
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST ROOM 318
,,,ILLAJI.1 II-Pa
10/16/23 SO/SV 9 3rd BLD 9 FL3 WEST STAFF BATHROOM
Y.-1,1GL,, I I./ I
10/16/23 SO/SV 9 3rd BLD 9 FL3 CENTER WAITING AREA
.1.-Pal-.., 10/16/23 SO/SV 9 3rd BLD 9 FL3 ELEVATOR LOBBY
,..1 ,aall ,all I u, 10/16/23 SO/SV 9 3rd BLD 9 FL3 ELEVATOR LOBBY
..,../l/LI.A.,/
10/16/23 SO/SV 9 3rd BLD 9 FL3 CENTER HALLWAY
.-N-Ilial/VA! I A./../
10/16/23 SO/SV 9 3rd BLD 9 FL3 NORTH STAIRWELL
10/16/23 SO/SV 9 3rd BLD 9 FL3 CENTER ROOM 315
Y.-A V I 1./../
10/16/23 SO/SV 9 3rd BLD 9 FL3 NURSES STATION
4,IllalllIll I Ill
,,all.alll-A-1 I I I
,JULlliall I I a
10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST WING HALLWAY
YOULl./VW I I J
.-..ILIGlIkl ,l I I, 10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST ROOM 302
..-VVV I I ll
10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST ROOM 304
YOLILSILISI I I I
10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST ROOM 305
YOUL-Ul.11. I I I LI
10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST ROOM 306
.1,-IllalIlIV I I a
10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST ROOM 306
.-1,,,,,,, I l-l/
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Facility Name Building 9 Type Of Equipment Inspected Strobes/ Speaker Strobes
Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
ANNUAL
10/16/23 10/16/23
Inspections Performed By Veterans Adminstation Fire Department (VAFD)
VP The The Joint Commission
Date Tested Device Type t ro es pea er rob
Location es Cust
Zone No.
Building Floor Comments
Notes Service
Performed Test
Result 10/16/23 SO/SV 9 3rd BLD 9 FL3 EAST STAIRWELL
YOULLA-Ill I G I
10/16/23 SO/SV 9 Attic BLD 9 ATTIC NORTH STAIRWELL
.1,-,ILLAJLI I GC
10/16/23 SO/SV 9 Attic BLD 9 ATTIC
.,..Illll I GO
.-N.A.J.GVV ,./ I GY
,, .., I [ prir The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
"rainpers Switches 10/16/23 10/16/23
ANNUAL
EC .02.03.05 [P3
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Joint Commision Environment Of Care Detail Report- EC .02.03 05 EP 3
Date Tested
Device Type Building Floor
Tamp e rs wtches Cust
Zone No.
Comments
Notes Service
Performed Test
10/16/23 TS 9 1st Stairwell 1 43020153
Tested Passes 10/16/23 TS 9 1st South Stairwell #1 43020162
10/16/23 TS 9 1st North Stairwell #3 43020164
10/16/23 TS 9 1st Center stairwell#2 43020177
10/16/23 TS 9 1st Ply Stair #2 43020178
10/16/23 TS 9 1st South by AM 115C 43020179
10/16/23 TS 9 1st PIV By RM 115C 43020180
10/16/23 TS 9 1st North Stairwell #3 43020179
10/16/23 TS 9 2nd South Stairwell #1 43020166
10/16/23 TS 9 2nd North Stairwell #3 43020168
10/16/23 TS 9 3rd South Stairwell #1 43020170
10/16/23 TS 9 3rd North Stairwell #3 43020172
10/16/23 TS 9 Attic Center stairwell#2 43020174
Pr V The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Flow Switches 10/16/23 10/16/23
ANNUAL
NFPA Standards NFPA 72, 2021
Flow Switches
Date Tested Device Type Building Floor Location Cust
Zone No.
Comments
Notes Service
Performed Test
10/16/23 WF 9 1st South Stairwell #1 43020161
10/16/23 WF 9 1st North Stairwell #3 43020163
10/16/23 WF 9 2nd South Stairwell #1 43020165
10/16/23 WF 9 2nd North Stairwell #3 43020167
10/16/23 WF 9 3rd South Stairwell #1 43020169
10/16/23 WF 9 3rd North Stairwell #3 43020171
10/16/23 WF 9 Attic Center stairwell#2 43020173
NFPA Standards NFPA 72, 2021 Ref NFPA 72, 2010
Inspections Performed By Veterans Adminstation Fire Department (VAFD) prir The Joint Commission
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection
Hest Detectors
Heat Detectors Date Tested Device T .e Build' Floor Location
Cust Zone No.
Comments Notes
Service Performed
Test
10/16/23 RR 9 Attic Center Top of shaft 43020012
10/16/23 RR 9 Attic Center Top of Shaft 2 43020025
Enter Svc Notification
10/16/23
ANNUAL
Facility Name Building 9 Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection Total Devices In Inventory Total Devices Tested
Inspections Performed By Veterans Adminstation Fire Department (VAFD)
V The Joint Commission Monitoring CO
NFPA Standards Ref
EC .02.03.05 EP 5 Joint Commision Environment Of Care Detail Report-
Emer Svc Notificat Time
Tested Zone No. Date Tested Notes Device Type Floor Building Location
Time Notification
Received 45 Seconds
Service Preformed
Tested
Test Results
Passed 10/16/23 Dial 45 1st FACP N32L1S6 1332
VA Fire Department
EC .02.03.05 EP 5
Alex. VA Fire Department
NFPA 72, 2021
Type Of Equipment Inspected Date Inspections Began Date Inspections Ended
Frequency/Type of Inspection
V
Main Drain Tests
EC .02.03.05 EP 9
k Standards Ref
NFPA 72, 2021
Joint Commision Environment Of Care Detail Report- EC .02.03.05 EP 9 v 'a.-in iser or on ro Valve & Type
., _,.,, „...__,.,.. . . rain e , s s a Ic
Location Pressure esr a
Pressure eturn me to Statis Presure Performed Result
10/16/23 MD 9 Control North End (3rd Floor) 135 120 2 min 45 Sec Tested Passed 10/16/23 MD 9 Control South End (3rd Floor) 125 110 3min. 15 sec. Tested Passed 10/16/23 MD 9 Control North End 2nd Floo 125 110 2 min. 50 sec Tested Passed 10/16/23 MD 9 Control South End (2nd Floor) 135 125 3min 5 sec. Tested Passed 10/16/23 MD 9 Control North End 2nd Floo 130 120 2min. 45 sec. Tested Passed 10/16/23 MD 9 Control South End (2nd Floor) 140 130 2 min. 40 sec. Tested Passed 10/16/23 MD 9 Control Attic 150 140 3 min Tested Passed
Fire Dept Connections
10/16/23
ANNUAL
NFPA Standards TJC Ref NFPA 25, 2020
Ref NFPA 25 2009 Table 5.1
Facility Name Type Of Equipment Inspected Date Inspections Began Date Inspections Ended Frequency/Type of Inspection Total Devices In Inventory ir-
Building 9 Company Performing Inspections VA Fire Department
EOC/EP Ref. # EC .02.03.05 EP 10
EC .02.03.05 EP 10
Fire Dept Connections
FDC Is Visible Couplings-Swivels Are Not Damaged And
Plugs & Caps Are In Place And
Gaskets In Place And In ID Signs Check Valve
Auto Drain Valve In Place &
Operating Properly
Clappers In Place &
Operating Properly
Date Tested Device Type Accessible Rotate Smoothly Undamaged Location Good Condition In Place Not Leaking Performed Result 10/16/23 I.DC Yes Yes Yes Yes Yes Yes Yes Yes 10/16/23 tIC Yes Yes Yes
Yes Yes Yes Yes Yes 10/16/23 DC Yes Yes Yes
10/16/23 Yes Yes Yes
| Page 1 |
| Page 2 |
| Page 3 |
| Page 4 |
| Page 5 |
| Page 6 |
| Page 7 |
| Page 8 |
| Page 9 |
| Page 10 |
| Page 11 |
| Page 12 |
| Page 13 |
| Page 14 |
| Page 15 |
| Page 16 |
| Page 17 |
| Page 18 |
| Page 19 |
| Page 20 |
| Page 21 |
| Page 22 |
File details come from the government source that posted it. Updated .