This document is a Solicitation for a Fire Alarm and Sprinkler Service Contract (Solicitation Number: 36C25624Q1010) issued by the Department of Veterans Affairs, Veterans Integrated Service Network 16.

The key details are:

  • The Solicitation is for fire alarm and sprinkler testing and maintenance services at a VA facility.
  • Prospective bidders must submit quotes for all work, including both fire alarm and sprinkler services. Partial bids will not be accepted.
  • Technical evaluation factors include: 1) Certification as a "Fire Works" Edwards Systems Technology Repair Company, 2) Authorization as an EST 3 Dealer, 3) NICET Level I or higher certification for fire alarm installation/supervision, 4) NICET Level 3 or higher certification for the Supervisory Fire Alarm Technician, 5) Demonstrated experience with EST-3 Networks, 6) Ability to meet 1-hour emergency response time, and 7) Current UL Laboratories ISO 9001 certification for the prime contractor. Sprinkler system factors include: 1) Certification with the Louisiana State Fire Marshal, 2) NICET Level 3 or higher certification for inspection and testing, and 3) Minimum 3 years of experience in sprinkler installation/maintenance.
  • Pricing will be evaluated for fairness and reasonableness. Award will be made to the lowest priced, technically acceptable offer.
  • All questions must be emailed to the Contracting Officer by June 27th, 3:00 PM CST.

View the file

Other files

File Type Posted
36C25624Q1010 0002.docx DOCX document
Fire Alarm Questions and Answers part 2.docx DOCX document
FY 2024 Annual Fire Alarm Bldg 45.pdf PDF
FY 2024 Annual Fire Alarm Bldg 7.pdf PDF
36C25624Q1010 0001.docx DOCX document
FY 2024 Outer buildings Annual Fire Alarm Test_Redacted.pdf PDF
FY 2024 Annual Fire Alarm Bldg 9.pdf PDF
36C25624Q1010_1.docx DOCX document
Wage Determination 2015-5175.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01-11101 E000

02-11101 E101
03-11101 E201
04-11101 E301
05-E000-SITE
06-E001-ULT-SITE
07-E100 FA Existing Riser Diagram
08-E103 Scope of work
09-EG000
10-FP100
11-FP101-ULT-SITE
12-FA101 FA Modified Riser Diagram
13-FA200-BLD1-B_THRU_attic AS BUILTS
14-FA201-BLD2-BASEMENT_GRNDFL As-Built
15-FA202-BLD2-1st_THRU_2nd As-Builts
16-FA203-BLD2-3RD_THRU_ATTIC As-Builts
17-FA204-BLD3-BSMT_THRU_3RD AS BUILTS
18-FA205-BLD3,4-ATTIC_THRU_1ST as-buil
19-FA206-BLD5-grnd_THRU_2ND as-builts
20-FA207-BLD6-grnd_THRU_2nd as-builts
21-FA208-BLD6-3RD_THRU_ATTIC as-builts
22-FA209-BLD7-SUBFLR AS BUILTS
23-FA210-BLD7-BSMT AS BUILTS
24-FA211-BLD7-FIRST AS builts
25-FA212-BLD7-SECOND As Builts
26-FA213-BLD7-THIRD As Builts
27-FA214-BLD7-FOURTH As Builts
28-FA215-BLD7-ATTIC
29-FA216-BLD8-BSMT_THRU_2 AS BUILTS
30-FA217-BLD8,9-3 AS-Built
31-FA218-BLD9-1_THRU_2 as-built
32-FA219-BLD9,13,14-ATTIC AS-Built
33-FA220-BLD15,16-1_THRU_1 As-Builts F
34-FA221-BLD18-20 As-Builts FA221 (1)
35-FA222-BLD21-22_39-42 As-Builts FA22
36-FA223-BLD45,46-FIRST_FLS AS BUILTS
37-FA224-BLD45,46-SECOND_FLS AS BUILTS
38-FA225-BLD45,136-ATTIC_1ST AS BUILTS
39-FA226-BLD24, 138, 142,147-FIRST_FL
40-FA227-RISER BLDG
41-FA228-RISER BLDG
42-FA229-RISER BLDG
43-FA230-RISER BLDG
44-FA231-RISER BLDG
45-FA232-RISER BLDG
46-FA233-RISER BLDG
47-FA234-RISER BLDG
48-FA235-RISER BLDG
49-FA236-RISER BLDG
50-FA237-RISER BLDG
51-FA238-RISER BLDG
52-FA239-RISER BLDG
53-FA240-RISER BLDG
54-FA241-RISER BLDG
55-FA3
56-FA4
57-FA242-RISER BLDG
58-FA243-RISER BLDG
59-FA244-RISER BLDG
60-FA245
61-FA246
62-FA247
63-FA248

File details come from the government source that posted it. Updated .