02.14.2022 ADDENDUM - AD101 - FLOOR PLAN - DEMO.pdf

PDF 473 KB Posted

Attached to
598-19-125 Relocate Medical Media
Solicitation number
36C25622R0041
Issued by

About this file

This document package includes construction documents and a related federal contract opportunity. The construction documents depict demolition plans and new construction layout for renovating approximately 2,800 square feet of unfinished storage space on the seventh floor of the JLM Memorial Veteran's Hospital to accommodate the relocation of Medical Media services. The renovation work includes architectural, mechanical, electrical, plumbing, fire protection, interior finishes and other construction labor and supervision.

The related federal contract opportunity is solicitation number 36C25622R0041 for project 598-19-125 to relocate Medical Media at the same Veteran's Hospital location. The contractor shall provide all supervision, labor, materials and equipment to complete the renovations depicted in the construction documents. The period of performance is 120 calendar days from notice to proceed. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW UNRATED PARTITION

NEW / EXISTING 1 HOUR BARRIER

EXISTING PARTITION TO BE REMOVED

EXISTING PARTITION

INDICATES PROJECT BOUNDARY

NEW / EXISTING 2 HOUR BARRIER

INDICATES ICRA BARRIER

7E-129

DIR

AR-GEMS

7E-127

IN STR

DVLPMNT

7E-125

GRECC

ED

SPEC PHYSICIAN

7E-123

GERIATRID

CONSLT

7E-121

GRECC

PROGRAM

7E-120

CORRIDOR

C7-37

CORRIDOR

C7-36

CORRIDOR

C7-35

CONFERENCE

ROOM

7E-119

EPIDEMIOLOGIST

7E-118B

INFECTOUS

CONTROL TEAM

7E-118

STORAGE

7E-118A

PHARMACOECONOMICS

DEPT.

7E-116

BIOMEDICAL

RESEARCH

7E-114

OFFICE

7E-114A

SPD STORAGE

7E-112A

EMS STORAGE

7E-111

WOMENS RR

7E-110

CORRIDOR

C7-34

TELEPHONE

7E-100

EDUCATION/TRAINING

7E-101

A/V ROOM

7E-105

JANITOR

7E-107

ELECTRIC

7E-108

STAIRS

S-74

KITCHEN

7E-104

SHARED

STORAGE

7E-117

STORAGE

7E-103

OIM STORAGE

7E-115

TELEPHONE

7E-102

MENS RR

7E-113

CANTEEN

STORAGE

7E-112

18 191715 21

H

G

J

L

8' - 9"

3'

7"

D1

D1

D1D1

D2

D2

D3

D4

D4

D4 D4

D5

D5

D5

D6

D6

D6

D7

D8

D9

D1

D1

D10

D11

D12

D13 D13

D14

D14

D15

K

D12

U.S. Department of Veterans Affairs

CONSULTANTS ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management

Drawing Title

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Building Number

Drawing Number

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

A

B

C

D

E

F

Revisions: Date:

VA FORM 08 - 6231

FULLY SPRINKLERED

3 4

MISSION CRITICAL

CONSTRUCTION DOCUMENTS

2/

/2

:1 7:

A

M C

:\U se rs \ts te ve ns \R ev it

Lo ca l\5

-1 9-

5_

M ed ic al

M ed ia _A rc h_ to dd

.s te ve ns

.rv t

FLOOR PLAN - DEMO CONSTRUCTION

DOCUMENTS

RELOCATE MEDICAL MEDIA

VAMC LITTLE ROCK

2020.08.10 JMc JDB

598-19-125

AD101

JLM

JDA PROJECT #: 598-19-125

2200 N. RODNEY PARHAM ROAD

SUITE 210

LITTLE ROCK, AR 72212

501-404-4811 jda@JohnsonDanforth.com

JohnsonDanforth & Associates

PARTITION LEGEND

KEY PLAN

DEMOLITION GENERAL NOTES

A CONTRACTOR SHALL NOTIFY COR AND ARCHITECT IMMEDIATELY IF ANY

DEVIATIONS BETWEEN EXISTING CONDITIONS AND DRAWINGS AND

SPECIFICATIONS ARE DISCOVERED DURING SITE VERIFICATION, DEMOLITION

OR NEW CONSTRUCTION.

B CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING

AND NEW CONSTRUCTION.

C ALL ITEMS SHOWN DASHED INDICATE ITEMS TO BE DEMOLISHED OR

SALVAGED. SEE SPECIFIC NOTES BELOW FOR ADDITIONAL INFORMATION.

REFER TO MECHANICAL, FIRE PROTECTION, PLUMBING, ELECTRICAL AND

TELECOM DRAWINGS FOR ADDITIONAL DEMOLITION AND NOTES.

D ALL OPENINGS AND SURFACES MADE BARE BY DEMOLITION AND/OR

REMOVAL OF MATERIALS SHALL BE REPAIRED AND/OR PATCHED TO MATCH

ADJACENT FINISH. PREPARE SURFACES TO RECEIVE NEW FINISH(ES).

E CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ICRA STANDARDS AND

POLICES; ICRA PROVIDED BY VA.

F INSTALL TEMPORARY DUST AND DEBRIS BARRIERS AND VESTIBULES

AROUND PROJECT LIMITS IN ACCORDANCE WITH INFECTON CONTROL PLAN -

PROVIDED BY COR. TEMPORARY BARRIERS ARE NOT TO RESTRICT

REQUIRED MEANS OF EGRESS PATHS AND WIDTHS.

G PROTECT EXISTING FIREPROOFING TO GREATEST EXTENT POSSIBLE DURING

PROJECT. ONCE DEMOLITION IS COMPLETE, CONTRACTOR SHALL REPAIR ALL

DAMAGED FIREPROOFING AND RESTORE MISSING FIREPROOFING, WHETHER

A RESULT OF DEMOLITION OPERATIONS OR NOT, TO MATCH EXISTING

RATING(S).

H IF HAZARDOUS MATERIAL ABATEMENT IS REQUIRED IN PROJECT SCOPE, REF.

TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

I ALL PENETRATIONS THROUGH RATED FLOOR/CEILING ASSEMBLIES AND

THROUGH FIRE RATED WALL AND SMOKE BARRIER ASSEMBLIES - THOSE

CREATED BY REMOVAL OF DEMOLISHED ITEMS UNDER THIS CONTRACT AND

THOSE DISCOVERED DURING CONSTRUCTION UNDER THIS CONTRACT AS A

RESULT OF PREVIOUS WORK AND THOSE CREATED BY NEW WORK UNDER

THIS CONTRACT - MUST BE SEALED AS PART OF THIS CONTRACT. ALL RATED

SEPARATIONS MUST MEET CURRENT CODE REQUIREMENTS.

J DEPICTION OF EXISTING CONDITIONS BASED ON OWNER-FURNISHED

DOCUMENTS AND LIMITED FIELD OBSERVATIONS. EXISTING ELEMENTS AND

CONDITIONS CONCEALED BY IN-PLACE EQUIPMENT AND FINISHES WERE NOT

OBSERVED OR INVESTIGATED. ONCE CUTTING AND SELECTIVE DEMOLITION

WORK IS COMPLETE REPORT ANY CONFLICTS TO COR. THE CONTRACTOR

SHALL MAKE ADJUSTMENTS AND/OR ALTERATIONS AS NECESSARY TO

INSTALL COMPLETE AND OPERABLE SYSTEMS IN ACCORDANCE WITH THE

CODES HAVING JURISDICTION AT NO ADDITIONAL COST TO GOVERNMENT.

FIRE PROTECTION

FP&C CONSULTANTS KC, LLC

1330 Burlington Street, Ste. 200 North Kansas City, MO 64116

MEP ENGINEER

INSIGHT ENGINEERING, PLLC

201 S. CHESTER, SUITE B

LITTLE ROCK, AR 72201

F

B A

D

C

E

PROJECT

AREAS

N

SCALE: 3/16" = 1'-0"

0 2'-8" 5'-4" 10'-8"3/16" = 1'-0"F3 FLOOR PLAN - DEMO

DEMOLITION KEYED NOTES

D1 DEMO EXISTING EXTERIOR WINDOWS AND PREP AREA FOR NEW

STOREFRONT WINDOWS; PROTECT ADJACENT INTERIOR AND EXTERIOR

MATERIALS AND FINISHES DURING DEMO AND NEW CONSTRUCTION

D2 EXISTING PIPING TO BE RELOCATED. SEE PLUMBING DRAWINGS

D3 DEMOLISH EXISTING EXHAUST DUCT. SEE MECHANICAL DRAWINGS

D4 DEMO EXISTING FLOORING TILES. PREP SLAB FOR NEW FLOORING.

D5 PREP ALL WALLS FOR NEW PAINT

D6 DEMO EXISTING CHAINLINK FENCE

D7 DEMO EXISTING WATER FOUNTAIN. SEE PLUMBING DRAWINGS.

D8 DEMO EXISTING WALL. SEE AE101 FOR LOCATION OF NEW WALL WITH

DOOR LOCATION

D9 ALL SHELVING/RACK SYSTEMS TO BE REMOVED. COORDINATE w/ V.A. FOR

STORAGE OR RELOCATION OR DISPOSAL OF RACKS

D10 DEMO PORTION OF EXISTING WALL. PREP AREA FOR FINISHED OPENING.

TO BE DONE AT FINAL PHASE OF PROJECT

D11 EXISTING PIPING TO REMAIN - REFERENCE NEW CONSTRUCTION FLOOR

PLAN

D12 DEMO EXISTING DOOR. TO BE REPLACED WITH NEW

D13 REMOVE EXISTING DOUBLE DOORS & FRAMES. INFILL WALL TO MATCH

ADJACENT.

D14 DEMO PORTION OF EXISTING WALL IN ORDER TO INSTALL NEW EXTERIOR

STOREFRONT WINDOWS

D15 DEMO GYP. BD. ON INTERIOR SIDE OF WALL AND REPLACE WITH FRP

7TH FLOOR SLAB ELEVATION = 492.67'

1 DOOR SCHEDULE 2.14.2022

Sheets
AD101 - FLOOR PLAN - DEMO
AE101 - FLOOR PLAN - NEW CONSTRUCTION
AE601 - WINDOW & DOOR SCHEDULES

File details come from the government source that posted it. Updated .