This document contains an amendment to a federal solicitation as well as the related solicitation opportunity. The amendment publicizes answers to vendor questions about a solicitation seeking inspection, cleaning, preventative maintenance, and emergency repair services for four cooling tower modules at a Veterans Affairs medical center. The incumbent cooling towers have been in service for approximately 15 years. The amendment clarifies that weekly, monthly, or quarterly inspections are not required, only biannual cleaning and preventative maintenance in early spring and late fall. It also states that water treatment services are normally provided by a separate contractor and need not be included. Responses to the solicitation are due by 1:00PM Central Time on September 22, 2022. The solicitation is set aside for service-disabled veteran-owned small businesses and issued by the VA Veterans Health Administration Network Contracting Office 16.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25622Q1595 0004_1.docx | DOCX document | |
| 36C25622Q1595 0004.pdf | ||
| 36C25622Q1595 0003_1.docx | DOCX document | |
| 36C25622Q1595 0003.pdf | ||
| 36C25622Q1595 0002.pdf | ||
| 36C25622Q1595 0002_1.docx | DOCX document | |
| 36C25622Q1595 0001_1.docx | DOCX document | |
| 36C25622Q1595_2.docx | DOCX document | |
| 36C25622Q1595_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE 7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO. 1. CONTRACT ID CODE
FACILITY CODE CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR
ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30 PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print) (Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
1 2
586-22-4-583-0082
Department of Veterans Affairs
Gulf Coast Veterans Health Care System
Network Contracting Office 16
400 Veterans Avenue
Biloxi MS 39531
Department of Veterans Affairs
Gulf Coast Veterans Health Care System
Network Contracting Office 16
400 Veterans Avenue
Biloxi MS 39531
To all Offerors/Bidders
36C25622Q1595
09-21-2022
X
The purpose of this amendment is to publicize answers to questions provided by interested vendors.
See next page.
PAUL FILHIOL
Contracting Officer
CONTINUATION PAGE
Proposal RFI #1 –
Can you confirm the model number of the cooling towers? 872A/V-4 does not match any model number currently available by Baltimore AirCoil that we can find.
872A/V is the model number. There are four modules combined together to form the system along with three condenser water pumps and associated controls.
All control system programming and components (including seven (7) VFDs shall be tested and PM’d twice per year by Johnson Controls, Inc. All control system PM and repairs shall be by JCI.
Cooling tower Inspection, PM, and Maintenance by others.
Proposal RFI #2 –
How many years have the cooling towers been in service?
Approx. 15 years
Proposal RFI #3 -
Regarding section 8.6.3.1 Cooling Tower Disinfection Procedure. I am being told that this is not something normally done by the maintenance contractor. This scope is normally performed by the water treatment specialist that is doing the water treatment for the facility already.
Please advise who your current water treatment specialist is contracted by the facility.
Correct. This requirement may be deleted.
RFI #4
The local Baltimore AirCoil authorized representative has declined to bid on this opportunity. Will a service provider authorized to work on similar non-BAC units be approved for this opportunity?
Yes, as long as OEM parts and methods are used for all maintenance and repairs.
Please note that cleaning and preventative maintenance is only expected to occur twice per year (early spring and late fall) and that no weekly, monthly, or quarterly inspections are required.
End of Document