36C25620R0069-078.pdf

PDF Posted

Attached to
Z1DA--CFM - Complete Sanipak Site Prep Federal contract opportunity
Solicitation number
36C25620R0069
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

About this file

36C25620R0069 Section 01 58 16 - Temporary Inside Signage.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--CFM - Complete Sanipak Site Prep, newest first.
File Type Posted
035-7PL100-N1 CEP Underground Plumbing N-1 Drawings.pdf PDF
VA SE Louisiana Drawings.pdf PDF
00494-7AS314 CEP Dock Wall Elevations F3 Drawings.pdf PDF
037-7PL101-N1 CEP Second Floor Plumbing Drawings.pdf PDF
037-7PL101-N1 CEP First Floor Plumbing N-1 Drawings.pdf PDF
192-7EP409 CEP First Floor Electric Room 1N100 Drawings.pdf PDF
00470-7AS204 CEP West Wall Elevations at Loading Dock Drawings.pdf PDF
171-7EP101-N1 CEP First Floor Power Plan N-1 Drawings.pdf PDF
00473-7AS207 CEP Loading Dock Elevations at Ramp Drawings.pdf PDF
36C25620R0069-086.pdf PDF
36C25620R0069-075.pdf PDF
36C25620R0069-090.pdf PDF
36C25620R0069-082.pdf PDF
36C25620R0069-080.pdf PDF
36C25620R0069-071.pdf PDF
36C25620R0069-081.pdf PDF
36C25620R0069-073.pdf PDF
36C25620R0069-076.pdf PDF
36C25620R0069-089.pdf PDF
36C25620R0069-074.pdf PDF
36C25620R0069-079.pdf PDF
36C25620R0069-087.pdf PDF
36C25620R0069-077.pdf PDF
36C25620R0069-072.pdf PDF
36C25620R0069-091.pdf PDF
36C25620R0069-070.docx DOCX document
36C25620R0069-088.pdf PDF
36C25620R0069-092.pdf PDF
36C25620R0069-093.pdf PDF
36C25620R0069-085.pdf PDF
36C25620R0069-069.docx DOCX document
36C25620R0069-084.pdf PDF
36C25620R0069-083.pdf PDF
Show all 33

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

07-01-15

01 58 16 - 1

SECTION 01 58 16

TEMPORARY INTERIOR SIGNAGE

PART 1 GENERAL

DESCRIPTION

This section specifies temporary interior signs.

PART 2 PRODUCTS

2.1 TEMPORARY SIGNS

A. Fabricate from 50 Kg (110 pound) mat finish white paper.

B. Cut to 100 mm (4-inch) wide by 300 mm (12 inch) long size tag.

C. Punch 3 mm (1/8-inch) diameter hole centered on 100 mm (4-inch) dimension of tag. Edge of Hole spaced approximately 13 mm (1/2-inch) from one end on tag.

D. Reinforce hole on both sides with gummed cloth washer or other suitable material capable of preventing tie pulling through paper edge.

E. Ties: Steel wire 0.3 mm (0.0120-inch) thick, attach to tag with twist tie, leaving 150 mm (6-inch) long free ends.

PART 3 EXECUTION

3.1 INSTALLATION

A. Install temporary signs attached to room door frame or room door knob, lever, or pull for doors on corridor openings.

B. Mark on signs with felt tip marker having approximately 3 mm (1/8-inch) wide stroke for clearly legible numbers or letters.

C. Identify room with numbers as designated on floor plans.

3.2 LOCATION

A. Install on doors that have room, corridor, and space numbers shown.

B. Doors that do not require signs are as follows:

1. Corridor barrier doors (cross-corridor) in corridor with same number.

2. Folding doors or partitions.

3. Toilet or bathroom doors within and between rooms.

4. Communicating doors in partitions between rooms with corridor entrance doors.

5. Closet doors within rooms.

C. Replace missing, damaged, or illegible signs.

- - - E N D - - -