36C25618B0678-018.pdf
PDF 15 MB Posted
- Attached to
- FAV-New Mental Health Building-Solicitation
- Solicitation number
- 36C25618B0678
About this file
36C25618B0678 Attch D 564-610_DRAWING_BID_050108_MEP.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25618B0678-0006001.pdf | ||
| 36C25618B0678-0006000.docx | DOCX document | |
| 36C25618B0678-0005000.docx | DOCX document | |
| 36C25618B0678-0005006.pdf | ||
| 36C25618B0678-0005005.pdf | ||
| 36C25618B0678-0005002.pdf | ||
| 36C25618B0678-0005001.pdf | ||
| 36C25618B0678-0005004.pdf | ||
| 36C25618B0678-0005003.pdf | ||
| 36C25618B0678-0004000.docx | DOCX document | |
| 36C25618B0678-0003000.docx | DOCX document | |
| 36C25618B0678-0002011.docx | DOCX document | |
| 36C25618B0678-019.pdf | ||
| 36C25618B0678-016.docx | DOCX document | |
| 36C25618B0678-017.pdf | ||
| 36C25618B0678-002.docx | DOCX document | |
| 36C25618B0678-0001001.pdf | ||
| 36C25618B0678-0001000.docx | DOCX document | |
| 36C25618B0678-001.docx | DOCX document | |
| 36C25618B0678-000.docx | DOCX document |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
C
E
E
ELECTRICAL LIGHTING SYMBOLS LIST
S
SYMBOL:
BLANK = SINGLE POLE 2 = DOUBLE POLE
3 = THREE-WAY 4 = FOUR-WAY
D = DIMMER K = KEY OPERATED
LV= LOW VOLTAGE L = LOCK
LM= LOW VOLTAGE MASTER P = WITH PILOT LIGHT
PB= PUSH BUTTON STATION RC= REMOTE CONTROL
T = TIMER OPERATED WP= WEATHER PROOF
X = EXPLOSION PROOF Mo= OCCUPANCY SENSOR
SWITCH
LIGHT FIXTURE CEILING MOUNTED
LIGHT FIXTURE, RECESSED, 2'x4' [610x1220mm];
LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED, 1'x8' [305x2439mm]; LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED FLUORESCENT, 2'x2' [610x610mm]; LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED FLUORESCENT,
610x610mm (2'x2'); LETTER INDICATES TYPE.
LIGHT FIXTURE, STRIP/INDUSTRIAL FLUORESCENT;
LETTER INDICATES TYPE.
LIGHT FIXTURE, WALL MOUNTED
LIGHTING, TWO HEAD EMERGENCY BATTERY POWER
LIGHT POLE, ONE MAST ARM, ONE LUMINAIRE
LIGHT POLE, TWO MAST ARMS, TWO LUMINAIRES
LIGHTING WALL PACK - EXTERIOR BUILDING
FLOOD LIGHT - EXTERIOR BUILDING
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS
AND FACES AS SHOWN
EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS
AND FACES AS SHOWN
NATURAL DAYLIGHT FIBER OPTIC LUMINAIRE
SUN TRACKING SOLAR COLLECTION MODULE
EMERGENCY LIGHTING CONTROL
OCCUPANCY SENSOR - DUAL TECHNOLOGY
DAYLIGHT LEVEL SENSOR
DESCRIPTION:TAG: SPEC SECTION:
SW
F#
F#
F#
F#
F#
F#
F#
XM#
F#
F#
F#
F#
F#
F#
F#
SM-#
ETD
SW-OC-D
SW-LS
26 27 26
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 51 00
26 09 33
26 09 33
ETD
OC
D
LS
ELECTRICAL POWER SYMBOL LIST
DP#__
LP
T
S
VFD
RC
C
J
SYMBOL:
TRANSFORMER, PLAN
EARTH GROUND
JUNCTION BOX
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF
CIRCUITS, NEUTRAL, AND SWITCH LEG CONDUCTORS. ONE
SEPARATE GREEN GROUNDING CONDUCTOR MUST BE FURNISHED
FOR EACH HOMERUN; NOT SHOWN
PULL BOX/ HAND HOLE
RIGID CONDUIT LINE = RC
PAD MOUNTED MEDIUM VOLTAGE SWITCH
PUSH BUTTON
DISTRIBUTION PANEL
LIGHTING PANEL
PANELBOARD CABINET, FLUSH MOUNTED
PANELBOARD CABINET, SURFACE MOUNTED
RECEPTACLE, CLOCK HANGER
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, QUADRAPLEX
RECEPTACLE, QUADRAPLEX WITH GROUND FAULT CIRCUIT
INTERRUPTER
RECEPTACLE, SINGLE
DUPLEX RECEPTACLE, TAMPERPROOF
DUPLEX RECEPTACLE, TAMPERPROOF WITH GROUND FAULT
CIRCUIT INTERRUPTER
DUPLEX RECEPTACLE, OCCUPANCY SENSOR CONTROLLED
RECEPTACLE, SPECIAL PURPOSE
A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.
B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.
C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.
D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.
E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.
F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R.
G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-50R.
H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.
RECEPTACLE, TAMPERPROOF WITH LOCKABLE COVER AND
GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, TAMPERPROOF WITH LOCKABLE COVER
RECEPTACLE, SWITCHED DUPLEX
3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &
RECEPTACLE.
ELECTRICAL POWER SYMBOL LIST
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
VARIABLE FREQUENCY DRIVE
SWITCH
TR-#
JB
HH-1
PS-#
PB
PANEL '##'
PANEL '##'
REC-DUP
REC-EM
REC-DUP-GFI
REC-QUAD
REC-QUAD-GFI
REE-SIM-520R
REC-TAMP
REC-TAMP-GFI
REC-OCC
REC-SIM-##R
REC-DUP
REC-DUP
REC-DUP
FB-#
26 22 00
26 05 26
26 05 33
26 05 41
26 13 16
26 09 39
26 24 16
26 24 16
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 27 26
26 05 33
SYMBOL: DESCRIPTION:TAG: SPEC SECTION: SYMBOL: DESCRIPTION:TAG: SPEC SECTION:
F = FUSED SWITCH K = KEY OPERATED
L = LOCK LM= LOW VOLTAGE MASTER
M = MANUAL MOTOR STARTING MC= MOMENTARY CONTACT
MP= MOTOR SNAP WITH PILOT LIGHT P = WITH PILOT LIGHT
(THERMAL TYPE)
PB= PUSH BUTTON STATION RC= REMOTE CONTROL
WP= WEATHER PROOF X = EXPLOSION PROOF
FDS-#
DS-#
FCS-#
MS-#
VFD-#
26 29 21
26 29 21
26 29 11
26 29 11
26 29 11
26 27 26
O
L
L
PMS
ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:
FACC = CENTRAL CONSOLE FACP = CONTROL PANEL
MFACP= MASTER CONTROL PANEL FAAP = ANNUNCIATOR PANEL
ALARM, FIRE, POST INDICATOR VALVE.
ALARM, FIRE, MANUAL PULL STATION
ALARM, SPEAKER/LIGHT, ONE ASSEMBLY
ALARM, SPEAKER
ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE
ALARM, VOICE COMMUNICATION PANEL
ALARM, TAMPER SWITCH
DETECTION SWITCH, ABORT
DETECTION SWITCH, VALVE TAMPER
DETECTOR, FLOW SWITCH
DETECTOR; LETTER INDICATES AS FOLLOWS:
BLANK = SMOKE DETECTOR
H = HEAT SMOKE
I = IONIZATION SMOKE
P = PHOTOELECTRIC SMOKE
IH = IONIZATION AND HEAT SMOKE
IP = IONIZATION AND PHOTOELECTRIC SMOKE
PH = PHOTOELECTRIC AND HEAT SMOKE
IPH = IONIZATION, PHOTOELECTRIC, AND HEAT
DETECTOR, SMOKE, FOR DUCT
ELECTROMAGNETIC TYPE DOOR HOLDER OUTLET
FIRE ALARM ADDRESSABLE MONITOR MODULE
FIRE ALARM ADDRESSABLE RELAY
FACP
P
PIV
ELECTRICAL SYSTEM SYMBOL LIST
SYMBOL:
CP
EPO
TS
H
DH
SYMBOL: DESCRIPTION:TAG: SPEC SECTION:
FA-100
FA-262
FA-130
VCC-1
FA-120
FA-122
FA-270
FA-160
FA-161
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
28 31 00
MM
AR
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2
:4
A
M E-000
ELECTRICAL COVER SHEET
STEWIEIMEG04/16/18 111
MTR
R
FS
FM
DSD
T
T
T
T
H
H
C
C
C
C
1 11 1 1 1 1
1S 1S1S 1S 1S 1S 1S
2 22 2 2 2 2
1. REFER TO EQUIPMENT SCHEDULES TO CROSS REFERENCE WHICH CONTROL DIAGRAMS
APPLY TO WHICH ITEMS OF EQUIPMENT.
2. EACH D.I., D.O., A.I. AND A.O. POINT SHOWN FOR ALL CONTROL DIAGRAMS SHALL BE
DISCRETE FROM ALL OTHER POINTS EXCEPT AS SPECIFICALLY NOTED.
3. ALL WIRING, CONTROL COMPONENTS, DEVICES AND PROGRAMMING SHOWN ON THESE
CONTROL DRAWINGS SHALL BE FURNISHED BY THE TCC UNLESS SPECIFICALLY NOTED
OTHERWISE.
4. ALL ACTUATORS SHALL BE OF THE ELECTRICAL TYPE FOR THIS PROJECT UNLESS AN
ACTUATOR IS SPECIFICALLY INDICATED ON THE DRAWINGS OR SPECIFICATIONS TO BE
PNEUMATIC.
5. ALL MODULATING DAMPER AND VALVE ACTUATORS SHOWN WITH POSITION FEEDBACK
SHALL HAVE THE VALVE POSITION DISPLAYED ON GRAPHICAL SCREEN ADJACENT TO THE
DAMPER/VALVE COMMAND SIGNAL. DISPLAYED VALVE POSITION SHALL BE FROM THE
FEEDBACK DEVICE/CIRCUIT (OUTPUT SIGNAL FROM THE FMCS TO THE ACTUATOR IS NOT
ACCEPTABLE)
6. MODULATING SIGNALS SHALL BE DISPAYED AS % OPEN (SIGNALS DISPLAYED AS % CLOSED
ARE NOT ACCEPTABLE).
7. PRESSURE TRANSMITTERS WHOSE SIGNAL IS UTILIZED FOR MAINTAINING DUCT STATIC
PRESSURE SHALL BE WIRED DIRECTLY TO THE CONTROLLER WHICH MODULATES FAN
SPEED. SIGNAL SHALL BE COMPLETELY INDEPENDENT OF THE BAS NETWORK.
8. PRESSURE TRANSMITTERS WHOSE SIGNAL IS UTILIZED FOR MAINTAINING DIFFERENTIAL
PRESSURE OF ANY PUMPED WATER SYSTEM (E.G. HEATING HOT WATER, CHILLED WATER
AND THE LIKE) SHALL BE WIRED DIRECTLY TO THE CONTROLLER WHICH MODULATES PUMP
SPEED. SIGNAL SHALL BE COMPLETELY INDEPENDENT OF THE BAS NETWORK.
9. ALL CONTROL COMPONENTS SUCH AS RELAYS, SWITCHES, DDC CONTROLLERS, ETC. SHALL
BE MOUNTED IN STEEL ENCLOSURES WITH STEEL MOUNTING BACKPLATES .
10. EACH CONTROL PANEL SHALL HAVE A LAMINATED COPY OF THE APPLICABLE SEQUENCE OF
OPERATION AND CONTROL DIAGRAM INDICATING THE POINTS, COMPONENTS AND
OPERATION OF EQUIPMENT ASSOCIATED WITH EACH PANEL.
11. TCC SHALL WIRE THE CONTROL SIGNAL FROM THE ASSOCIATED AIR HANDLING UNIT
CONTROL PANEL TO CONTROL THE OPERATION OF SMOKE DAMPERS IN ACCORDANCE WITH
SEQUENCE OF OPERATION. TCC SHALL FURNISH ALL WIRING, CONDUIT, TRANSFORMERS,
FUSING AND ALL OTHER ELECTRICAL COMPONENTS REQUIRED FOR COMPLETE
INSTALLATION.
12. TCC SHALL EXTEND CONTROL SIGNAL FROM ADDRESSABLE RELAY DEVICE SERVING EACH
AIR HANDLING UNIT. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS. TCC SHALL EXTEND
AND TERMINATE WIRING AS REQUIRED FOR EQUIPMENT SHUTDOWN.
13. TCC SHALL EXTEND 24 VOLT POWER FROM CONTROL POWER SHOWN ON FLOOR PLANS TO
ALL TERMINAL AIR BOX CONTROLLERS JUNCTION BOX. TCC SHALL FURNISH ALL WIRING,
SUPPORTS, FUSING SPACE, TOGGLE SWITCHES, AND ALL OTHER ELECTRICAL COMPONENTS
REQUIRED FOR COMPLETE INSTALLATION.
14. TCC SHALL FURNISH CONDUIT RUNS AS REQUIRED FOR OUTDOOR EQUIPMENT AND FOR
EQUIPMENT INSTALLED REMOTELY FROM THE MAIN BUILDING THAT IS BEING MONITORED OR
CONTROLLED BY THE FMCS.
15. ELEMENT LENGTHS FOR BOTH MIXED AIR TEMP SENSORS AND LOW LIMIT TEMP SWITCHES
SHALL BE MINIMUM 1 LINEAR FOOT PER SQUARE FOOT OF COIL SURFACE AREA. FURNISH
MULTIPLE SENSORS AND SWITCHES AS NEEDED TO ACHIEVE REQUIRED ELEMENT LENGTHS.
LOCATE RESET SWITCHES MAX. 6'-6" ABOVE ADJACENT STANDING SURFACE (I.E. ROOF,
PLATFORM OR FLOOR) SO THE RESET SWITCH CAN BE CYCLED WITHOUT THE NEED FOR A
LADDER.
16. TO PREVENT GENERATOR OVERLOADING, TCC SHALL PROGRAM A STAGGERED START TIME
FOR ALL MECHANICAL EQUIPMENT THAT IS CONTROLLED BY ECC TO INCLUDE, BUT NOT
LIMITED TO, AIR HANDLERS, PUMPS, EXHAUST FANS, AND CHILLERS. THE FIRST EQUIPMENT
SHALL START 2 MINUTES (ADJ.) FROM THE TIME THE FMCS RECEIVES THE SIGNAL THAT THE
TRANSFER SWITCH CHANGED TO EMERGENCY POWER SOURCE WITH ALL EQUIPMENT BEING
ENERGIZED WITHIN A 20 MINUTE (ADJ.) TIME SPAN. COORDINATE ORDER OF EQUIPMENT
STAGING WITH OWNER'S REPRESENTATIVE.
17. CONTROL DIAGRAMS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL REQUIRED
CONTROL DEVICES AND COMPONENTS. REFER TO FLOOR PLANS, FLOW DIAGRAMS AND
DETAILS FOR ADDITIONAL CONTROL DEVICES, COMPONENTS AND REQUIREMENTS NOT
SHOWN ON THESE CONTROL DRAWINGS.
18. TCC SHALL FURNISH ALL CONTROL COMPONENTS AND ACCESSORIES AS REQUIRED FOR
EQUIPMENT TO BE CONTROLLED AS DESCRIBED IN THE SEQUENCE OF OPERATION
REGARDLESS OF WHETHER ALL CONTROL COMPONENTS OR POINTS ARE SHOWN IN THE
ASSOCIATED CONTROL DIAGRAM.
TEMPERATURE CONTROL GENERAL NOTES:
1. THE SIZE OF EACH BRANCH DUCT TO A TERMINAL AIR BOX (TAB) SHALL MATCH THE TAB’S
INLET SIZE UNLESS THE BRANCH IS GREATER THAN 6 FEET IN LENGTH, THEN THE BRANCH
SHOULD BE INCREASED ONE DUCT SIZE, OR NOTED OTHERWISE.
2. ALIGN TEMPERATURE SENSORS WITH LIGHT SWITCHES AND WHEN IN CLOSE PROXIMITY TO
EACH OTHER.
3. FURNISH ACCESS DOORS AT ALL DUCT MOUNTED EQUIPMENT.
VENTILATION GENERAL NOTES:
1. THE SIZE OF BRANCH PIPING TO TERMINAL HEATING DEVICES AND COILS SHALL BE 3/4"
UNLESS NOTED OTHERWISE.
2. PIPE DRAIN LINES FROM EQUIPMENT TO NEAREST FLOOR DRAIN.
3. INSTALL ALL REFRIGERANT LIQUID AND SUCTION PIPING AND SIZED PER EQUIPMENT
MANUFACTURER RECOMMENDATIONS.
PIPING GENERAL NOTES:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO FURNISH
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO FURNISH PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,
AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE
SEALED AIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER
FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,
PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE
TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO FURNISH THE DESIRED NC LEVELS
WITHIN ROOMS.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY BETWEEN DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
13. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
15. FURNISH CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
16. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
I.E. INVERT ELEVATION (FOR REFERENCE ONLY)
PRESSURE SWITCHPS
CO CLEANOUT
MIXING VALVEMV
ELECTRICAL TO PNEUMATIC VALVEEP
C COMMON
MECHANICAL ABBREVIATION KEY
ABBR: DESCRIPTION:
DIFFERENTIAL PRESSURE GAUGE (RANGE)DPG (0-2")
DIFFERENTIAL PRESSURE SWITCHDPS
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
NC NEW CONNECTION
NOT IN CONTRACTNIC
CFSD CONTROL/FIRE/SMOKE DAMPER
EA EXHAUST/RELIEF AIR
FD FIRE DAMPER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FSD FIRE/SMOKE DAMPER
MA MIXED AIR
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
SD SMOKE DAMPER
TRANSFER DUCTTD
UC-1 DOOR UNDERCUT BY OTHERS (1" TYPICAL)
TERMINAL AIR BOXTAB
TYPICALTYP
UNO UNLESS NOTED OTHERWISE
NORMALLY CLOSEDN.C.
NORMALLY OPENN.O.
BAS BUILDING AUTOMATION SYSTEM
ENGINEERING CONTROL CENTERECC
FAN
MOTOR
CONTACTOR
PUMP
AIR FLOW SWITCH
ACT
DS
DP
CS
VS
FM
NORMALL CLOSED CONTACT
NORMALLY OPEN CONTACT
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
NOT ALL SYMBOLS MAY APPLY.
ACTUATOR
DOOR SWITCH
DIFFERENTIAL PRESSURE SWITCH
CURRENT SWITCH
VIBRATION SWITCH
FLOW METER
DIRECTION OF AIR FLOW
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
RISE IN DIRECTION OF AIR FLOWR
DUCT CAP
DROP IN DIRECTION OF AIR FLOWD
DUCT DOWN
DUCT UP
SUPPLY/OUTSIDE AIR DUCT SECTION
RETURN AIR DUCT SECTION
EXHAUST/RELIEF AIR DUCT SECTION
4-WAY DIFFUSER WITH BLANKOFF IN ONE DIRECTION
CD-1
6/115
AIR TERMINAL PROPERTIES SYMBOL
NECK SIZE/CFM
TERMINAL AIR BOX (REFER TO SCHEDULE)###
### TERMINAL AIR BOX w/REHEAT COIL (REFER TO SCHEDULE)
HUMIDIFIERH
OPPOSED BLADE DAMPER (REFER TO SCHEDULE)
PARALLEL BLADE DAMPER (REFER TO SCHEDULE)
AIRFLOW MEASUREMENT SYMBOL
XX - AHU SYMBOL
Y - SEQUENTIAL NUMBER
XX-Y
CONTROL VALVE (TWO-WAY)
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
PITCH PIPE IN DIRECTION
DIELECTRIC CONNECTION
UNION/FLANGE
BALANCING VALVE (NUMBER INDICATES GPM)
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
DIRECTION OF FLOW IN PIPE
NEW CONNECTION
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
THROTTLING VALVE
AUTOMATIC BALANCING VALVE
MIXING VALVE
CONTROL VALVE (THREE-WAY)
SOLENOID VALVE
CHECK VALVE
SAFETY/RELIEF VALVE
PRESSURE REDUCING VALVE (LIQUID/GAS)
PRESSURE REDUCING VALVE (STEAM)
TRIPLE DUTY VALVE (ANGLE TYPE)
TRIPLE DUTY VALVE (IN-LINE TYPE)
VACUUM BREAKER
"WYE" - STRAINER
"WYE" - STRAINER W/SHUTOFF VALVE AND HOSE CONNECTION WITH CAP
BASKET STRAINER
FLEXIBLE CONNECTION
PRESSURE/TEMPERATURE TEST PLUG
REDUCER - REFERENCE SPECIFICATION
FOR CONCENTRIC/ECCENTRIC AND FOT/FOB
SUCTION DIFFUSER WITH SUPPORT FOOT
AUTOMATIC AIR VENT
MANUAL AIR VENT
DRAIN VALVE WITH HOSE CONNECTION AND CAP
ALIGNMENT GUIDE
PIPE ANCHOR
EXPANSION JOINT
CHILLED WATER RETURNCWR
CHILLED WATER SUPPLYCWS
NATURAL GASG
HEATING WATER RETURNHWR
HEATING WATER SUPPLYHWS
SAFETY RELIEF VENTSV
DRAINDPP
GAS REGULATOR VENTGV
NOT ALL SYMBOLS MAY APPLY.
METERM
PUMP
SOLENOID VALVE
CHECK VALVE
SAFETY/RELIEF VALVE
PRESSURE REDUCING VALVE (LIQUID/GAS)
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
DUCT FLOW METER
FLOW METER
FM
FLOW SWITCH
F
FS FLOW SENSOR
STATIC SWITCH
DUCT SMOKE DETECTOR
HEATING/ COOLING COIL
FILTER
AIR BLENDER
MANUAL MOTOR STARTER
W/THERMAL OVERLOAD
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
NOT ALL SYMBOLS MAY APPLY.
SP
T
THERMOSTAT
TEMPERATURE SENSOR (DUCT MOUNTED)
THERMOSTAT/SENSOR WITH HEAVY DUTY ENCLOSURET
TEMPERATURE SENSOR WITH WELL
T
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
AVERAGING TEMPERATURE
SENSOR
PROBE TEMPERATURE SENSOR
LOW LIMIT TEMPERATURE
SWITCH
HUMIDITY SENSOR
(DUCT MOUNTED)
H
HUMIDISTAT SENSOR
HUMIDISTAT / SENSOR
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
(DUCT MOUNTED)
CARBON DIOXIDE SENSOR
(DUCT MOUNTED)
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
DIFFERENTIAL PRESSURE SENSOR
P PRESSURE SENSOR (DUCT MOUNTED)
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N O R
HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
LINE TYPE KEY:
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR
SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL
MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS WHETHER SHOWN OR NOT.
RATINGS WERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 11/02/2017.
FIRE / SMOKE BARRIER DESIGNATIONS
1-HOUR SMOKE BARRIER WALL
NON-RATED SMOKE PARTITION (CORRIDORS)
1-HOUR FIRE REATED BARRIER
2-HOUR FIRE RATED BARRIER
TEMPERATURE CONTROLS CONTRACTORT.C.C.
SECURITY CONTRACTORS.C.
AUDIO/VISUAL CONTRACTORA.V.C.
NURSE CALL CONTRACTORN.C.C.
CIVIL CONTRACTORC.C.
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
CONSTRUCTION MANAGERC.M.
T
CONTROLS SYMBOLS
ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT
M ROOM HUMIDISTAT (MOISTURE)/TRANSMITTER - WALL MOUNT
TT TEMPERATURE TRANSMITTER
TT TEMPERATURE TRANSMITTER, AVERAGING ELEMENT
MT MOISTURE (HUMIDITY) TRANSMITTER
PT PRESSURE TRANSMITTER
SPS STATIC PRESSURE SENSOR
FT FLOW TRANSMITTER
CURRENT TRANSMITTER
CONDUCTIVITY TRANSMITTER
SMOKE DETECTOR
PRESSURE DIFFERENTIAL TRANSMITTER
PRESSURE DIFFERENTIAL SWITCH
HAND SWITCH (HAND-OFF-AUTO SWITCH)
VALVE OR DAMPER POSITION CONTROLLER
LOCAL RECORDING TIME CLOCK (RUNTIME)
TEMPERATURE SWITCH, LOW (FREEZESTAT)
IT
CT
SD
PDT
PDS
HS
ZC
KR
TSL
TSH
LC
LT
PSH
TEMPERATURE SWITCH, HIGH (FREEZESTAT)
LEVEL CONTROLLER
LEVEL TRANSMITTER
PRESSURE SWITCH HIGH
PSL PRESSURE SWITCH LOW
EPT ELECTRONIC TO PNEUMATIC TRANSDUCER
AT CARBON DIOXIDE TRANSMITTER
AT CARBON DIOXIDE TRANSMITTER
AT OCCUPANCY SENSOR
LTCP LOCAL TEMPERATURE CONTROL PANEL
HVAC CONTROL PANEL
VARIABLE SPEED MOTOR CONTROLLER
ECC
INTEGRATE CONTROL POINT ON REMOTE GRAPHICS
WORKSTATION AT ENERGY CONTROL CENTER
TC
TEMPERATURE CONTROLLER. SEE SEQUENCE OF
OPERATION
PC
PRESSURE CONTROLLER. SEE SEQUENCE OF
OPERATION
SC
SPEED CONTROLLER. SEE SEQUENCE OF
OPERATION
FC FLOW CONTROLLER. SEE SEQUENCE OF OPERATION
FSH FLOW SWITCH HIGH
FSL FLOW SWITCH LOW
CO2
CO
OC
HVAC
VSMC
KC TIME CLOCK CONTROLLING EQUIPMENT ON A SCHEDULE
TEMPERATURE SENSING ELEMENT FOR
TRANSMITTING TEMPERATURE TO EMCS
(FURNISH 12 INCHES [200mm] MINIMUM
LENGTH IN DUCT WHEN SPACE PERMITS.)
A SENSOR WITH AVERAGING ELEMENT TO
TRANSMIT TEMPERATURE TO EMCS
MOTOR STARTER
MOTOR STARTERM
SST
STS
START/STOP
STATUS
VALVE OR DAMPER POSITION FEEDBACK ZS
EM ELECTRICITY METER
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :3
P
M M-000
MECHANICAL COVER SHEET
JAYACHTYLHIL04/16/18 89
S
S
S
S
1S1S 1 S
S
1S
1S
1S
1S
1S
S
S
S
S
S
S
S
1 11 1 1
1 11 1 1
11 11
2 22 2 2
2 2
2 2 2 22 2 2
2 2 2
T
CONF/RPT RM
103-49
GEN STOR
104-49
ENVIRO STOR
105-49
OPEN OFFICE
106-49
STAFF LOUNGE
107-49
STAFF LOCKER
109-49
TLT
108-49
PHYS OFFICE
110-49
EQIP STOR
111-49
HEAD NURSE
112-49
ASSIST NURSE
113-49
TLT
115-49
ALCOVE
117-49
SALLY PORT
C118-49
ELECTRICAL
E170-49
CAMERAS
119-49
SOILED UTILITY
120-49
PAT STOR
121-49
SOILED LINEN
122-49
PAT SHWR
123-49
EXAM
124-49
CORR
C128-49
SOCIAL WORKER
125-49
EXAM
126-49
INTERVIEW
129-49
HAC
132-49
CLEAN UTILITY
130-49
CORR
C133-49
CLEAN LINEN
131-49
DATA RM
T134-49
TECH RM
T135-49
LIVING ROOM
C163-49
CART STORAGE
136-49
ISO/SECLUSION
137A-49
ANTE RM
137-49
ISO TLT
137B-49
ISO/RESTRAINT
137C-49
PAT LADRY
138-49
PAT RM
139-49
PAT RM
140-49
NOURISH
141A-49
DINING
141-49
TLT
142-49
PAT RM
143-49PAT RM
144-49
PAT RM
146-49
PAT RM
147-49
PAT RM
149-49
PAT RM
150-49
PAT RM
151-49
PAT RM
152-49
PAT RM
153-49
CONSULT RM
157-49
BARIATRIC RM
159-49
PAT RM
160-49
PAT RM
161-49
BARIATRIC RM
162-49
WORK RM
165-49
TEAM RM
166-49
MED RM
167-49
TLT
140A-49
TLT
139A-49
TLT
144A-49
TLT
143A-49
TLT
147A-49
TLT
146A-49
TLT
150A-49
TLT
149A-49
TLT
152A-49
TLT
151A-49
TLT
153A-49
HAC
154-49
BARI TLT
159A-49
TLT
160A-49
BARI TLT
162A-49
TLT
161A-49
MECHANICAL
M168-49
DAY RM
148-49
GROUP RM
156-49
QUIET RM
155-49
CORR
C101-49
ELECTRICAL
E169-49
INTERVIEW
127-49
CORR
C102-49
WAITING
116-49
TLT
114-49
NURSE STATION
164-49
CORR
C158-49
CORR
C145-49
VESTIBULE
C100-49
M A
T C
H L
IN
E
M A
T C
H L
IN
E
MH-101
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :3
P
M MH-100
FIRST FLOOR PLAN - VENTILATION
ZONING
JAYACHTYLHIL04/16/18 90
N
O R HT
1/8" = 1'-0"1
FIRST FLOOR PLAN - VENTILATION ZONING
S
S
S
S
1S1S 1 S
S
1S
1S
1S
1S
S
S
S
S
S
S
S
S
S
S
1 11 1
1 11 1
11 11
2 22 2 2
2 22
2 22 2 22 2 2
T
T
A G
CONSULT RM
157-49
GROUP RM
156-49
QUIET RM
155-49
TLT
153A-49
HAC
154-49
PAT RM
153-49
PAT RM
152-49
TLT
152A-49
TLT
151A-49
PAT RM
151-49
PAT RM
150-49
TLT
150A-49
TLT
149A-49
PAT RM
149-49
DAY RM
148-49
PAT RM
147-49
TLT
146A-49
TLT
147A-49
PAT RM
146-49 PAT RM
144-49
TLT
144A-49
TLT
143A-49
PAT RM
143-49
TLT
142-49 DINING
141-49
NOURISH
141A-49
PAT RM
140-49
TLT
139A-49
TLT
140A-49
PAT RM
139-49
PAT LADRY
138-49
ISO/RESTRAINT
137C-49
ANTE RM
137-49 ISO TLT
137B-49
ISO/SECLUSION
137A-49
CART STORAGE
136-49
CORR
C128-49
DATA RM
T134-49
TECH RM
T135-49
BARIATRIC RM
162-49
BARI TLT
162A-49
TLT
161A-49
PAT RM
161-49
PAT RM
160-49BARIATRIC RM
159-49
BARI TLT
159A-49
TLT
160A-49
LIVING ROOM
C163-49
WORK RM
165-49
TEAM RM
166-49
MED RM
167-49
C
FD E
H
N
B
2.2
1.3
CORR
C158-49
NURSE STATION
164-49
6.1
CORR
C145-49
1.2
C.3
C.1
C.5
C.6
.8
7.1
C.2 C.4
14x14 EA ABOVE
MH-101
RG-92
9x9/150
EG-92
9x9/100
EG-92
9x9/100
EG-92
9x9/100
RG-91
6x6/45
EG-92
9x9/100
SD-92
9x9/155
SD-92
9x9/175
RG-92
9x9/150
RG-93
10x10/155
RG-92
9x9/130
RG-92
9x9/130
EG-92
9x9/100
EG-91
9x9/75
SD-92
9x9/155
SD-92
9x9/75
EG-92
9x9/100
SD-92
9x9/75
EG-92
9x9/100
RG-91
6x6/55
SD-92
9x9/155
RG-92
9x9/130
SD-92
9x9/155
EG-92
9x9/100
SD-92
9x9/75
EG-92
9x9/100
RG-91
6x6/55
SD-92
9x9/155
EG-92
9x9/100
RG-91
6x6/80
EG-92
9x9/100
SD-92
9x9/75
SD-92
9x9/175
RG-92
9x9/130
SD-92
9x9/155
RG-91
6x6/55
EG-92
9x9/100
EG-92
9x9/100
SD-92
9x9/75
RG-92
12x12/130
SD-92
9x9/155
EG-92
9x9/125
RG-92
6x6/45
SD-92
9x9/145
EG-92
9x9/100
SD-92
9x9/75
EG-92
9x9/100
RG-92
9x9/120
SD-92
9x9/145
RG-92
9x9/125
SD-92
9x9/125
SD-92
9x9/100
RG-95
14x14/410
RG-95
14x14/410
RG-95
14x14/405
RG-96
16x16/490
RG-96
16x16/490
EG-25
14/410
SD-12
8/230
RG-23
10/230
SD-11
6/145
RG-95
14x14/385
RG-22
8/145
SD-92
9x9/185
EG-93
10x10/200
SD-92
9x9/110
RG-95
14x14/470
RG-93
10x10/245
MH-101
49-TAB-35
16x16 RA BELOW
12x10 EA
12x10 EA ABOVE
18x16 RA BELOW
12x10 EA ABOVE
8ø 9ø
SD-93
10x10/235
10x10 8x8
10x10
6x6
6ø
8ø
49-TAB-34
49-TAB-33
20x20 SA
49-HWHU2
49-HWUH1
SD-92
9x9/180
RG-91
6x6/45
RG-99
30x30/2880
RG-92
9x9/100
EG-92
9x9/100
SD-92
9x9/155
SD-2
9x9/100
SD-93
10x10/245
SD-93
10x10/245
SD-93
10x10/245
SD-92
9x9/155
SD-92
9x9/155
SD-93
10x10/235
SD-92
9x9/75
SD-92
9x9/155
SD-92
9x9/75
10ø
SD-93
10x10/245
(TYP.4)
10x10
10x10
49-TAB-38
49-TAB-37
49-TAB-36
49-TAB-39
49-TAB-32
49-TAB-31
49-TAB-30
49-TAB-29
49-TAB-28
49-TAB-26
49-TAB-25
49-TAB-24
49-TAB-23
49-TAB-22
49-TAB-21
49-TAB-20
49-TAB-19
49-TAB-40
49-TAB-42
49-TAB-41
9x9
49-TAB-27
18x16 RA
SD-93
10x10/245
SD-92
9x9/165
36x24
SD-94
12x12/400
16x16 SA ABOVE
SD-94
12x12/400
MH-201
SD-94
12x12/400
SD-94
12x12/400
14x12
12x8 SA SD-94
12x12/400
SD-94
12x12/400
SD-94
12x12/400
14x14 SA ABOVE
10x10
6x6
RG-94
12x12/325
(TYP.2)
SD-94
12x12/325
(TYP.2)
RG-94
12x12/400
SD-94
12x12/400
10x10
SD-14
12/410
8x6
SD-55
18x12/575
RR-54
16x16/575
RR-54
16x16/590
14ø
14x14 EA ABOVE
SD-92
9x9/165
SD-92
9x9/165
14ø
T
M A
T C
H L
IN
E
49-HWHU2
MH-201
MH-201
MH-201
MH-201
MH-201
MH-201
MH-201
24x20 SA BELOW
T
T
T
T
T
T
T T
T T
T
49-TAB-41
T
T
T
T
T T
T
TT
SD-13
10/385
SD-55
18x12/590
T
6x8 RA BELOW
10x10 RA BELOW
22x24 RA
14x14 EA 12x10 EA
14x14 EA
20x20 RA BELOW
18x16 RA BELOW
16x10 RA
6ø RA BELOW
6x8 RA BELOW
12x10 EA ABOVE 14x16 RA BELOW
10x10 RA BELOW
16x16 RA BELOW 14x16 RA BELOW
12x12
12x8 SA
14x12 SA
10x10 SA
20x20 SA
24x20 SA
22x24 RA BELOW
20x22 SA BELOW
20x22 SA BELOW
14x14 SA ABOVE
16x16 SA BELOW
16x16 SA ABOVE
14x14 SA ABOVE
14x12 SA
14x14 EA ABOVE
20x20 RA BELOW
10x10
10x10 14x14
14x14
14x14 SA ABOVE
12x12 SA BELOW
12x10 EA ABOVE
18x16 BELOW
10x10 SA
10x10
12x10
14x14 x
SD-93
10x10/245
SD-93
10x10/245
18x10 SA ABOVE
12x12 BELOW x
12x12 SA ABOVE
12x10 RA
M A
T C
H L
IN
E
M A
T C
H L
IN
E
9x9 SA
20x20 RA BELOW
R
D
16x16 SA ABOVE
BRANCH CONNECTED
TO 12"x12" SA BELOW.
BRANCH CONNECTED
TO 12"x12" SA BELOW.
D
D
12x10 SA
16x14 SA
D
26x16 RA
D
26x16 RA
R
D
D
DR
14x14 EA ABOVE
20x18 RA BELOW
D
20x20 SA BELOW
D
R
MH-101
20x22 SA BELOW
49-TAB-37
FINISHED FLOOR
EL (100' - 0")
T.O. ROOF SLAB
EL (116' - 0")
CATWALK
EL (109' - 10")
/2
/2
MH-201
MH-201
MAINTENANCE
CATWALK
LIGHTING FIXTURE
(TYP.)
ROUTE DUCTWORK, PIPING
AND EQUIPMENT AS HIGH AS
POSSIBLE WHERE CROSSING
THE MAINTENANCE
CATWALK. LOCATE VALVES
AND DAMPERS CLOSE TO
THE CATWALK.
14x14 SA ABOVE
6x6 RA
9x9 SA
6x6 RA
14x14 EA
20x20 RA
LEVEL 1
EL: 100' - 0"
T.O. ROOF SLAB
EL: 116' - 0"
FINISHED FLOOR
EL (100' - 0")
T.O. ROOF SLAB
EL (116' - 0")
CATWALK
EL (109' - 10")
9x9 EA
20x20 RA
14x14 EA
14ø SA
MH-201
MH-201
ROUTE DUCTWORK, PIPING AND
EQUIPMENT AS HIGH AS POSSIBLE
WHERE CROSSING THE
MAINTENANCE CATWALK. LOCATE
VALVES AND DAMPERS CLOSE TO
THE CATWALK.
9x9 SA 9x9 EA
MAINTENANCE
CATWALK
20x22 SA
49-TAB-39
LEVEL 1
EL: 100' - 0"
T.O. ROOF SLAB
EL: 116' - 0"
FINISHED FLOOR
EL (100' - 0")
T.O. ROOF SLAB
EL (116' - 0")
CATWALK
EL (109' - 10")
12x14 SA
12ø SA
49-TAB-22
12x14 RA
T
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :4
P
M MH-101
PARTIAL FIRST FLOOR PLAN WEST -
MECHANICAL HVAC
JAYACHTYLHIL04/16/18 91
GENERAL SHEET NOTES:
1. COORDINATE INSTALLATION OF FIRE
PROTECTION, HVAC AND PLUMBING SYSTEMS
WITH MAINTENANCE CATWALK. ROUTE PIPING
AND DUCTWORK IN A MANNER THAT ALLOWS
MAXIMUM CLEARANCE ABOVE THE CATWALK.
LOCATE ISOLATION VALVES, DAMPERS,
TERMINAL BOX ACCESS, AND ALL OTHER
ITEMS THAT REQUIRE MAINTENANCE ACCESS
WITHIN REACH FROM THE CATWALK. REFER
TO ARCHITECTURAL DRAWING AE-541.
2. SUPPLY DUCT FROM FAN TO TERMINAL AIR
BOX SHALL BE +3" PRESSURE CLASS. SUPPLY
DUCT FROM TERMINAL AIR BOX TO OUTLET
SHALL BE +1" PRESSURE CLASS. REUTRN
DUCT AND EXHAUST DUCT SHALL BE -2"
PRESSURE CLASS.
KEYNOTES:
1. ROUTE 4" ROUND EXHAUST FROM DRYER AND
TERMINATE WITH A BACKDRAFT DAMPER AND
DRYER VENT THROUGH THE WALL.
COORDINATE COLOR SELECTION WITH
ARCHITECT. REFER TO MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
N O R
HT
1/8" = 1'-0"1
PARTIAL FIRST FLOOR PLAN WEST - MECHANICAL HVAC
1/4" = 1'-0"2
TYPICAL PATIENT ROOM - SECTION
3/16" = 1'-0"3
TYPICAL PATIENT TOILET - SECTION
FLOOR PLAN -WEST
FLOOR PLAN - EAST
COURTYARD
N
KEYPLAN
3/16" = 1'-0"4
NOURISH/DINING HVAC - SECTION
1S
1S
1S
1S
S
S
S
S
S
S
S
S
S
S
11 11
2 2 2
T
G
MECHANICAL
M168-49
CLEAN LINEN
131-49
CLEAN UTILITY
130-49
INTERVIEW
129-49
EXAM
126-49
EXAM
124-49
SOILED LINEN
122-49
SOILED UTILITY
120-49
ELECTRICAL
E170-49
CORR
C128-49
DATA RM
T134-49
CORR
C133-49
HAC
132-49
PAT SHWR
123-49
SOCIAL WORKER
125-49
PAT STOR
121-49
CAMERAS
119-49
ALCOVE
117-49
CORR
C101-49
TLT
115-49
ASSIST NURSE
113-49
HEAD NURSE
112-49
EQIP STOR
111-49
PHYS OFFICE
110-49
TLT
108-49
STAFF LOCKER
109-49
STAFF LOUNGE
107-49
OPEN OFFICE
106-49
ENVIRO STOR
105-49
GEN STOR
104-49
CONF/RPT RM
103-49
H
N
N
Q
P
ELECTRICAL
E169-49
INTERVIEW
127-49
CORR
C102-49
S
12.1
R
TLT
114-49
6.1
6.4
C.7
7.1
TECH RM
T135-49
WAITING
116-49
VESTIBULE
C100-49
13.1
T
R1
SALLY PORT
C118-49
ISO/SECLUSION
137A-49
24x18 x3
EG-91
6x6/75
EG-91
6x6/55
SD-92
9x9/160
RG-93
10x10/160
SD-92
9x9/160
SD-92
9x9/160
RG-93
10x10/160
EG-51
8x8/95
SD-92
9x9/160
RG-93
10x10/160
RG-93
10x10/165
SD-92
9x9/165
EG-92
9x9/145
EG-91
6x6/50
RG-24
12/305
SD-1
12/305
SD-91
6x6/50
RG-23
10/220
RG-22
8/140
RG-21
6/60
RG-22
8/165
EG-22
8/135
RG-24
12/345
EG-25
14/500
SD-12
8/250
SD-14
12/420
SD-14
12/420
EG-22
8/150
EG-23
10/230
SD-14
12/440
(TYP.2)
EG-92
9x9/125
EG-92
9x9/125
49-TAB-9
49-TAB-10
49-TAB-12
49-TAB-11
49-TAB-14
49-TAB-16
49-TAB-15
49-TAB-17
49-TAB-18
49-TAB-4
49-TAB-349-TAB-1
49-TAB-2
49-TAB-7
49-TAB-6
40x28 SA
49-HWUH4
49-HWUH3
SD-91
6x6/100
SD-91
6x6/100
SD-92
10x10/275
SD-12
8/250
SD-12
8/220
SD-92
9x9/130
SD-92
9x9/130
SD-94
12x12/400
SD-11
6/60
SD-12
8/165
SD-12
8/140
SD-91
6x6/50
SD-92
9x9/225
RG-24
12/345
RG-24
12/325
RG-91
6x6/45
TG-1
8/150
TG-1
10/230
(TYP.2)
TG-1
8/150
10x10
10ø
8ø
49-TAB-5
6x6
8ø
10ø
10ø
8ø
6ø 6ø
6ø4ø 6x8
10x10 10x10
14x10
RG-94
12x12/400
49-TAB-13
RG-94
12x12/325
(TYP.2)
SD-94
12x12/325
(TYP.2)
12x12
12x12
RR-52
12x10/300
(TYP.2)
12x10
12x10
12x10
SD-53
14x10/310
(TYP.2)
RG-93
10x10/225
8x8 8x8
10x6
10x10
12ø
RR-53
14x14/380
(TYP.2)
SD-91
6x6/50
49-TAB-8
10x10
6x6
SD-92
9x9/130
6x6
RG-24
12/325
12x14
6x6
14ø x1
E
A A
B O
V E
10x10
12ø
42x28 RA
22x24 R A
40x28 SA
16x14 6ø
6ø 12ø 12ø
14x12
8ø
9x9
18x16 RA BELOW 12x12 EA ABOVE
10" TD
8" TD
49-HWUH3
SD-11
6/95
49-TAB-1
RG-91
6x6/100
49-HWUH4
SD-91
6x6/50
MH200
24x18 SA
36x24 SA
18x16 RA BELOW
14x12 RA BELOW
38x26 RA BELOW
22x20 RA
12x12
36x24
12ø
6x6
M A
T C
H L
IN
E
M A
T C
H L
IN
E
6x6
EG-51
8x8/100
26x16 RA
MH-102
R
R
16x16 EA
D
R
26x16 RA
D
49-TAB-13
D
R6x6 SA
RG-93
10x10/160
20x18 RA x1
E
A
LEVEL 1
EL: 100' - 0"
T.O. ROOF SLAB
EL: 116' - 0"
QR
FINISHED FLOOR
EL (100' - 0")
T.O. ROOF SLAB
EL (116' - 0")
CATWALK
EL (109' - 10")
8ø SA
12x14 RA
10ø RA 16x18 RA
8ø RA 10ø RA
6x6 EA
12ø SA
9x9 RA
10x10 EA10x10 RA
10ø RA
12x14 RA
12x12 EA
16x18 RA
6" RA 8" RA
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:3 :1
P
M MH-102
PARTIAL FIRST FLOOR PLAN EAST -
MECHANICAL HVAC
JAYACHTYLHIL04/16/18 92
GENERAL SHEET NOTES:
1. SUPPLY DUCT FROM FAN TO TERMINAL AIR
BOX SHALL BE +3" PRESSURE CLASS. SUPPLY
DUCT FROM TERMINAL AIR BOX TO OUTLET
SHALL BE +1" PRESSURE CLASS. REUTRN
DUCT AND EXHAUST DUCT SHALL BE -2"
PRESSURE CLASS.
N
O R HT
1/8" = 1'-0"1
PARTIAL FIRST FLOOR PLAN EAST - MECHANICAL HVAC FLOOR PLAN -WEST
FLOOR PLAN - EAST
COURTYARD
N
KEYPLAN
3/16" = 1'-0"2
OFFICES - HVAC SECTION
UP
S
S
S
S
S
S
S
S
S
S
2 2
MECHANICAL
M168-49
CLEAN LINEN
131-49
CLEAN UTILITY
130-49
INTERVIEW
129-49
EXAM
126-49
EXAM
124-49
ELECTRICAL
E169-49
ISO/SECLUSION
137A-49
49-BHW2
49-BHW1
DDC CONTROL PANEL
49-ERV1
49-SH1
49-ACCH1
49-ACCH2
4" AIR INTAKE TO
WATER HEATER
4" AIR INTAKE TO
WATER HEATER
4" FLUE TO WATER
HEATER
4" FLUE TO WATER
HEATER
FURNISH BIRD SCREEN AT THE
OPENING AND TERMINATE
WITH ELBOW TO PREVENT
WATER ENTRY (TYP. 5).
FURNISH BIRD SCREEN AT THE
OPENING AND TERMINATE
WITH ELBOW TO PREVENT
WATER ENTRY (TYP. 5).
EXHAUST AIR LOUVER
REFER TO ARCHITECTURAL
DRAWINGS.
OUTSIDE AIR LOUVER.
REFER TO ARCHITECTURAL
DRAWINGS.
49-TAB-44
22x14 E A
49-TAB-43
SD-53
12x8/300
(TYP.2)
RR-54
12x12/540
4" WATER HEATER
COMBUSTION AIR INTAKE
SD-54
12x12/420
(TYP.2)
4" HUMIDIFIER
COMBUSTION VENT
6" BOILER VENT
49-AFMD1 (RETURN FAN)
49-AFMD2
(SUPPLY FAN)
14x14 E A
18x14 E A x3
E
A
40x14 E A
16x10 SA 24x24 EA x3
S
A
24x18 SA
22x24 OA
VENT HOOD
4" HUMIDIFIER COMBUSTION
AIR INTAKE. INSULATE PIPING
TO PREVENT CONDENSATION
6" BOILER COMBUSTION AIR
INTAKE.
4" WATER FLUE
WATER HEATER VENT
49-MOD4
49-MOD1 49-MOD5
49-MOD2
49-MOD3
14x14 RA
14x14 RA
42x28 RA
24x22 O A
42x42 OA
36x36 O A
22x20 RA
RG-93
10x10/160
16x14 R A
MH-200
40x14 EA
49-SAD2
22x20 RA
20x18 RA
20x18 RA
14x14 EA
20x18 RA
BELOW.
49-SAD1
x1
S
A
D
M A
T C
H L
IN
E
LEVEL 1
EL: 100' - 0"
T.O. ROOF SLAB
EL: 116' - 0"
T.O. WALL
EL: 118' - 2 1/2"
T.O. COPING
EL: 118' - 10 1/2"
CATWALK (TOP)
EL: 110' - 1 1/2"
FINISHED FLOOR
EL (100' - 0")
T.O. ROOF SLAB
EL (116' - 0")
CATWALK
EL (109' - 10")
36x46 EA
49-MOD3
49-MOD5
24x24 EA
24x24 EA
49-ERV1
49-AHU1
40x14 EA
16x10 SA
60x29 EA
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :0
P
M MH-200
FIRST FLOOR MECHANICAL ROOM
PLAN HVAC
JAYACHTYLHIL04/16/18 93
GENERAL SHEET NOTES:
1. SUPPLY DUCT FROM FAN TO TERMINAL AIR
BOX SHALL BE +3" PRESSURE CLASS. SUPPLY
DUCT FROM TERMINAL AIR BOX TO OUTLET
SHALL BE +1" PRESSURE CLASS. REUTRN
DUCT AND EXHAUST DUCT SHALL BE -2"
PRESSURE CLASS.
KEYNOTES:
1. FURNISH 4" WATER HEATER FLUE AND 4" VENT
PER WATER HEATER PER MANUFACTURER'S
RECOMMENDATIONS.
N
O R HT
1/4" = 1'-0"1
FIRST FLOOR MECHANICAL ROOM PLAN
NO SCALE2
MECHANICAL ROOM SECTION-49-ERV1
T.O. ROOF SLAB
EL: 116' - 0"
A C D EB C.1
CATWALK (TOP)
EL: 110' - 1 1/2"
10x12 EA
20x20 RA
9x9 SA
6x6 SA 10x12 EA
6x6 EA 10x10 RA
20x20 RA
10x10 SA
8x8 SA
10x10 RA
12x12 SA
9x9 SA
14x14 EA
9x9 RA
20x20 RA 9x9 EA 9x9 EA 6x6 RA 9x9 SA 9x9 SA
6x6 RA
9x9 EA
9x9 EA
9x9 SA
14x14 EA
8ø RA
20x20 RA
20x20 RA
14x14 EA
T.O. ROOF SLAB
EL: 116' - 0"
ACDE BC.1
CATWALK (TOP)
EL: 110' - 1 1/2"
22x20 SA 16x16 SA22x20 SA
14x14 SA 12x12 SA
20x24 SA
5ø SA
9x9 RA
14ø SA
22x20 SA
49-TAB-39
9x9 EA
16x16 SA 12x12 SA
6x6 RA
4ø SA 4ø SA 6x6 RA
12x12 SA
9x9 EA 9x9 RA
5ø SA
12x12 RA
6ø SA
8ø SA
12x12 SA
18x16 RA
12x10 EA
9x9 SA
9x9 EA
T.O. ROOF SLAB
EL: 116' - 0"
6 4 23 2.26.1
CATWALK (TOP)
EL: 110' - 1 1/2"
16x14 RA
14x14 EA
16x16 RA
49-TAB-22
10x10 SA
36x24 SA
18x20 RA
14x14 EA
9x9 SA 14x14 RA9x9 EA
10x10 EA
8x6 SA
9x9 RA
9x9 SA
16x14 RA
9x9 EA
6x6 RA
9x9 SA 14ø EA
12ø SA
12x14 SA
14x14 EA
16x14 RA
T.O. ROOF SLAB
EL: 116' - 0"
642 32.2 6.1
CATWALK (TOP)
EL: 110' - 1 1/2"
12x14 SA
14x14 SA
20x20 SA
49-TAB-40
12ø SA
4ø SA 6x6 RA 9x9 EA
5ø SA
9x9 RA 8x6 SA
14x14 RA
6ø SA
9x9 RA
20x20 SA20x20 SA
10x10 SA
9x9 SA
14x14 RA
26x16 RA
T.O. ROOF SLAB
EL: 116' - 0"
CF DE
CATWALK (TOP)
EL: 110' - 1 1/2"
8x6 RA
6ø RA
10x12 EA
10x10 RA
8x6 RA
9x9 SA
16x14 RA
10x10 RA
9x9 SA10x12 EA
9x9 SA
6x6 RA 9x9 EA
9x9 SA 9x9 SA
12x12 SA
12x12 SA
9x9 SA
6ø RA
6x6 EA
6ø RA
9x9 SA9x9 RA
T.O. ROOF SLAB
EL: 116' - 0"
C FD E
CATWALK (TOP)
EL: 110' - 1 1/2"
20x20 SA
10x10 SA10x10 SA 12x12 RA5ø SA
6ø RA 6x6 EA
10x10 SA
6x6 RA 4ø SA
12x12 RA 9x9 RA
5ø SA 9x9 EA 6x6 RA
6ø SA
T.O. ROOF SLAB
EL: 116' - 0"
8642 32.2 6.1
CATWALK (TOP)
EL: 110' - 1 1/2"
16x18 RA
10x16 RA
20x20 RA
16x18 RA10x12 EA
9x9 SA
9x9 SA
9x9 SA
9x9 RA 9x9 SA 9x9 EA 6x6 SA
10x10 SA
10x10 RA 9x9 SA
6x6 RA 9x9 SA
9x9 EA 9x9 EA
9x9 SA
9x9 SA
T.O. ROOF SLAB
EL: 116' - 0"
6 4 23 2.26.1
CATWALK (TOP)
EL: 110' - 1 1/2"
16x16 SA
12x12 SA
16x16 SA 12x18 SA 10x18 SA
20x20 RA
12x10 EA
9x9 RA
5ø SA 5ø SA
9x9 RA
9x9 EA 6x6 RA 9x9 RA
10x18 SA
12x12 SA
9x9 EA
49-TAB-27
6x6 RA
4ø SA 10x10 SA
10x10 RA
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :1
P
M MH-201
MECHANICAL SECTION VIEWS
JAYACHTYLHIL04/16/18 94
3/16" = 1'-0"1
SECTION VIEW - NORTH PATIENT ROOMS - FACING NORTH - MECHANICAL HVAC
3/16" = 1'-0"2
SECTION VIEW - NORTH PATIENT ROOMS - FACING SOUTH - MECHANICAL HVAC
3/16" = 1'-0"3
SECTION VIEW - EAST PATIENT ROOMS - FACING EAST - MECHANICAL HVAC
3/16" = 1'-0"4
SECTION VIEW - EAST PATIENT ROOMS - FACING WEST - MECHANICAL HVAC
3/16" = 1'-0"5
SECTION VIEW - SOUTH PATIENT ROOMS - FACING SOUTH - MECHANICAL HVAC
3/16" = 1'-0"6
SECTION VIEW - SOUTH PATIENT ROOMS - FACING NORTH - MECHANICAL HVAC
3/16" = 1'-0"7
SECTION VIEW - WEST PATIENT ROOMS - FACING WEST - MECHANICAL HVAC
3/16" = 1'-0"8
SECTION VIEW - WEST PATIENT ROOMS - FACING EAST - MECHANICAL HVAC
S
S
S
S
1S1S 1 S
S
1S
1S
1S
1S
S
S
S
S
S
S
S
S
S
S
1 11 1
1 11 1
11 11
2 22 2 2
2 22
2 22 2 22 2 2
A GC
FD E
H N P
B
2.2
1.3
12.1
DATA RM
T134-49
TECH RM
T135-49
LIVING ROOM
C163-49
CART STORAGE
136-49
ISO/SECLUSION
137A-49
ANTE RM
137-49
ISO TLT
137B-49
ISO/RESTRAINT
137C-49
PAT LADRY
138-49
PAT RM
139-49
PAT RM
140-49
NOURISH
141A-49
DINING
141-49
TLT
142-49
PAT RM
143-49
PAT RM
144-49
PAT RM
146-49
PAT RM
147-49
PAT RM
149-49
PAT RM
150-49
PAT RM
151-49
PAT RM
152-49
PAT RM
153-49
CONSULT RM
157-49
BARIATRIC RM
159-49
PAT RM
160-49
PAT RM
161-49
BARIATRIC RM
162-49
WORK RM
165-49
TEAM RM
166-49
MED RM
167-49
TLT
140A-49
TLT
139A-49
TLT
144A-49
TLT
143A-49
TLT
147A-49
TLT
146A-49
TLT
150A-49
TLT
149A-49
TLT
152A-49
TLT
151A-49
TLT
153A-49
HAC
154-49
BARI TLT
159A-49
TLT
160A-49
BARI TLT
162A-49
TLT
161A-49
MECHANICAL
M168-49
DAY RM
148-49
GROUP RM
156-49
QUIET RM
155-49
NURSE STATION
164-49
CORR
C158-49
6.1
1.2
C.3
6.4
C.1
C.5
C.6 .8
7.1
C.2
C.4
MH-101
MH-101
1"HWS
1 1/2"HWS
49-TAB-34
49-TAB-33
49-HWHU2
49-HWUH1
49-TAB-38
49-TAB-37
49-TAB-36
49-TAB-39
49-TAB-35
49-TAB-32
49-TAB-31
49-TAB-30
49-TAB-29
49-TAB-28
49-TAB-26 49-TAB-25 49-TAB-24 49-TAB-23
49-TAB-22
49-TAB-21
49-TAB-20
49-TAB-19
49-TAB-40
49-TAB-42
49-TAB-41
49-TAB-27
1 1/4"HWS
1 1/2"HWR
1"HWS
2"HWR
1"HWS
2"HWR
2"HWS
3/4"HWR
1"HWR
1 1/2"HWS
1 1/4"HWS
1 1/2"HWR
1 1/4"HWR
1 1/2"HWS
1 1/4"HWS
1 1/4"HWR
1 1/4"HWR
1 1/2"HWS
2"HWR
3/4"HWS
1"HWR
1 1/4"HWR
1 1/4"HWS
1 1/2"HWR
2"HWS
M A
T C
H L
IN
E
M A
T C
H L
IN
E
DP
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :3
P
M MP-101
PARTIAL FIRST FLOOR PLAN WEST -
MECHANICAL PIPING
JAYACHTYLHIL04/16/18 95
N O R
HT
1/8" = 1'-0"1
PARTIAL FIRST FLOOR PLAN WEST - MECHANICAL PIPING.
GENERAL SHEET NOTES:
1. COORDINATE INSTALLATION OF FIRE
PROTECTION, HVAC AND PLUMBING SYSTEMS
WITH MAINTENANCE CATWALK. ROUTE PIPING
AND DUCTWORK IN A MANNER THAT ALLOWS
MAXIMUM CLEARANCE ABOVE THE CATWALK.
LOCATE ISOLATION VALVES, DAMPERS,
TERMINAL BOX ACCESS, AND ALL OTHER
ITEMS THAT REQUIRE MAINTENANCE ACCESS
WITHIN REACH FROM THE CATWALK. REFER
TO ARCHITECTURAL DRAWING A-541.
FLOOR PLAN -WEST
FLOOR PLAN - EAST
COURTYARD
N
KEYPLAN
1S
1S
1S
1S
S
S
S
S
S
S
S
S
S
S
11 11
2 2 2
G
MECHANICAL
M168-49
CLEAN LINEN
131-49
CLEAN UTILITY
130-49
INTERVIEW
129-49
EXAM
126-49
EXAM
124-49
SOILED LINEN
122-49
SOILED UTILITY
120-49
ELECTRICAL
E170-49
CORR
C128-49
DATA RM
T134-49
CORR
C133-49
HAC
132-49
PAT SHWR
123-49
SOCIAL WORKER
125-49
PAT STOR
121-49
CAMERAS
119-49
ALCOVE
117-49
CORR
C101-49
TLT
115-49
ASSIST NURSE
113-49
HEAD NURSE
112-49
EQIP STOR
111-49
PHYS OFFICE
110-49
TLT
108-49
STAFF LOCKER
109-49
STAFF LOUNGE
107-49
OPEN OFFICE
106-49
ENVIRO STOR
105-49
GEN STOR
104-49
CONF/RPT RM
103-49
H
N
N
Q
P
ELECTRICAL
E169-49
INTERVIEW
127-49
CORR
C102-49
S
12.1
R
TLT
114-49
6.1
6.4
C.7
7.1
TECH RM
T135-49
WAITING
116-49
VESTIBULE
C100-49
13.1
T
R1
SALLY PORT
C118-49
ISO/SECLUSION
137A-49
49-TAB-9
49-TAB-10
49-TAB-12
49-TAB-11
49-TAB-14
49-TAB-1649-TAB-15
49-TAB-17
49-TAB-18
49-TAB-4
49-TAB-3
49-TAB-1
49-TAB-2
49-TAB-7
49-TAB-6
49-HWUH4
49-HWUH3
49-TAB-5
1"HWS
1 1/4"HWR
1"HWS
REFER TO CIVIL DRAWINGS
FOR CONTINUATION
SLEEVE AND VENT NATURAL GAS
PIPING IN PLUMBING CHASE. PIPE MUST
ENTER BUILDING ABOVE GRADE.
GAS PRESSURE REGULATOR 49-GPR1.
INCOMING PRESSURE: 12 PSI +/- 2 PSI
REDUCE PRESSURE TO 2 PSI AT
BUILDING ENTRANCE. FLOW: 5400 CFH
(INCLUDES ANTICIPATED FUTURE
LOAD)
1 1/4"HWR
1 1/4"HWR
1"HWS
MP200
1"HWR
1 1/4"HWS
1 1/4"HWS
1"HWR
2"HWR
2"HWS
1 1/4"HWR
49-TAB-13
49-TAB-8
2"G
M A
T C
H L
IN
E
M A
T C
H L
IN
E
2"HWS
2"HWR
2"G
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :3
P
M MP-102
PARTIAL FIRST FLOOR PLAN EAST -
MECHANICAL PIPING
JAYACHTYLHIL04/16/18 96
N O R
HT
1/8" = 1'-0"1
PARTIAL FIRST FLOOR PLAN EAST - MECHANICAL PIPING.
GENERAL SHEET NOTES:
1. FURNISH ISOLATION VALVE AND DIRT LEG FOR
EACH PIECE OF GAS BURNING EQUIPMENT.
2. REFER TO GI-004 FOR LOCATIONS OF RATED
WALLS.
FLOOR PLAN -WEST
FLOOR PLAN - EAST
COURTYARD
N
KEYPLAN
UP
S
S
S
S
S
S
S
S
S
S
2 2
MECHANICAL
M168-49
CLEAN LINEN
131-49
CLEAN UTILITY
130-49
INTERVIEW
129-49
EXAM
126-49
EXAM
124-49
ELECTRICAL
E169-49
MP-200
49-BHW2
49-BHW1
49-P5
49-P2
49-P1
DDC CONTROL PANEL
DDC CONTROL PANEL
49-ERV1
49-SH1
49-ACCH1
4"CWR
4"CWS
2" STEAM
49-ACCH2
CHW BUFFER TANK
49-AS1
49-TAB-44
3"CWR
3"CWS
1 1/2"H W
S 1 1/2"H
W R
2 1/2"HWR
2 1/2"HWS
2"HWR
49-TAB-43
2"HWS
2"HWR
4"CWR
3"HWS
3"HWS
3"HWS
49-P4 BELOW
49-P3 ABOVE
REFER TO STRUCTURAL
DRAWING SB-302 FOR
CHILLER PAD DETAIL.
(TYP.2)
REFER TO CIVIL DRAWINGS FOR
COORDINATION OF CHILLED
WATER LINES AND SITE UTILITIES.
49-P7
49-P6
NATURAL GAS FLOWMETER 49-NGFM1
FURNISH 2" TAP ON NATRUAL GAS
PIPING WITH VALVE AND CAP TO
SERVE FUTURE SECOND FLOOR.
GAS PRESSURE REGULATOR 49-GPR2.
INCOMING PRESSURE: 2 PSI
REDUCE PRESSURE TO 12" W.C.
FLOW: 2700 CFH
ROUTE VENT THROUGH WALL TO
EXTERIOR OF BUILDING
2 1/2"HWR
2 1/2"HWS
2" STEAM
3"G
"G
49-ET1
49-ET2
POT FEEDER
POT FEEDER
1"C
WS
"C
W S
49-P8
49-P9
49-P10
49-P11
VIV
MH-200
DOMESTIC
WATER PUMPS
(TYP.4)
49-BP1
49-WH1
49-WH2
2"G
49-AHU1
3"CWR
3"CWS
M A
T C
H L
IN
E
NP
CATWALK
EL (109' - 10")
49-BHW1
49-BHW2
49-P149-P2
49-P6
49-P7
CHW BUFFER TANK
49-SH1
49-AS1
3"G
49GM1
2"HPS
3/4"HWR
3/4"HWS
3/4"CW
3/4"G
2"HPS
3"HWS 3"HWS
2 1/2"HWR
2 1/2"HWR
4"CWR
4"CWR
3"CWS
3"CWR
1 1/2"HWR 3"HWS
3"HWS
2 1/2"HWR
2 1/2"HWS
1/2"CW
4"CWR
4"CWR
4"CWS
4"CWR
49-P4
49-P3
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of 160
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMERLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Medical Center Director:
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:2 :4
P
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.