36C25618B0678-0005005.pdf
PDF 216 KB Posted
- Attached to
- FAV-New Mental Health Building-Solicitation
- Solicitation number
- 36C25618B0678
About this file
36C25618B0678 0005 Attch E missing GI-003 Sheet 10262018 01.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25618B0678-0006001.pdf | ||
| 36C25618B0678-0006000.docx | DOCX document | |
| 36C25618B0678-0005000.docx | DOCX document | |
| 36C25618B0678-0005006.pdf | ||
| 36C25618B0678-0005002.pdf | ||
| 36C25618B0678-0005001.pdf | ||
| 36C25618B0678-0005004.pdf | ||
| 36C25618B0678-0005003.pdf | ||
| 36C25618B0678-0004000.docx | DOCX document | |
| 36C25618B0678-0003000.docx | DOCX document | |
| 36C25618B0678-0002011.docx | DOCX document | |
| 36C25618B0678-019.pdf | ||
| 36C25618B0678-016.docx | DOCX document | |
| 36C25618B0678-017.pdf | ||
| 36C25618B0678-018.pdf | ||
| 36C25618B0678-002.docx | DOCX document | |
| 36C25618B0678-0001001.pdf | ||
| 36C25618B0678-0001000.docx | DOCX document | |
| 36C25618B0678-001.docx | DOCX document | |
| 36C25618B0678-000.docx | DOCX document |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLEARANCE REQUIREMENTS AND PROTECTIVE PANEL AT LAVATORY
CLEAR
FLOOR
SPACE
1. BOTTOM OF PANEL SHALL BE AS HIGH AS POSSIBLE AND
STILL CONCEAL AND PROTECT PIPES.
2. PLACE LAVATORY BOWL AS FAR FORWARD AS POSSIBLE
AND CUT OUT PIPE PROTECTION PANEL AROUND BOWL.
3. REFER TO ADA/ABA 603.3
M
IN
9" M
IN
M
IN
M A
X
M A
X
KNEE CLEARANCE
8" MIN
TOE CLEARANCE
6" MAX
17" MIN
30" MIN
M
IN
D E
P T
H
M
IN
M A
X CLEAR
FLOOR
SPACE
30" MIN
M
IN
D E
P T
H
M
IN
M A
X
STANDARD LAVATORY STANDARD LAVATORY LIGATURE-RESISTANT
LAVATORY
OBJECT
NOTES:
1. OBJECTS PROJECTING FROM WALLS WHOSE
LEADING EDGES ARE BETWEEN 27" AND 80"
ABOVE FINISH FLOOR SHALL NOT
PROTRUDE MORE THAN 4" INTO WALKS,
WALLS, CORRIDORS, PASSAGEWAYS, OR
AISLES.
2. OBJECTS WHOSE LEADING EDGES ARE AT
OR BELOW 27" ABOVE FINISH FLOOR, MAY
PROTRUDE ANY AMOUNT.
3. WALKS, HALLS, CORRIDORS, PASSAGEWAYS,
AISLES, OR OTHER CIRCULATING SPACES
SHALL HAVE A MINIMUM 80" CLEAR
HEADROOM.
2' -3
B
E
LO
W
4" MAXIMUM
T H
A N
'-3
H
IG
H E
R
6' -8
M
IN
IM
U M
ANY AMOUNT
OBJECT
6" MIN. 6" MIN.
18" MIN,
24" MAX
63" MIN
M
IN
M A
X
ALCOVES SHALL BE A MINIMUM
18" DEEP. IN ADDITION, ALCOVES SHALL
BE A MINIMUM 63" WIDE AND A MINIMUM
OF 32" WIDE FOR A SINGLE FOUNTAIN.
COORDINATE ALCOVE SIZE WITH THE SIZE
AND NUMBER OF DRINKING FOUNTAINS
PROVIDED FOR REQUIRED CLEARANCES.
IF CONFLICT OCCURS,CONTRACTOR
SHALL SUBMIT RECOMMENDATION FOR
ARCHITECT'S REVIEW AND APPROVAL
IF ALCOVE IS GREATER THAN 24" DEEP,
THEN ALCOVE SHALL BE A MINIMUM OF
36" WIDE.
RECESSED FOUNTAINS:
1.
2.
ACCESSIBLE
NOTE:
DRINKING FOUNTAINS SHALL BE INSTALLED IN ACCORDANCE
WITH APPLICABLE ADA/ABA GUIDELINES.
STANDARD
5'
M
IN
IM
U
M
C
LE
A R
3'
0" M
IN
IM
U M
6" M
A X
IM
U
M
2' - 0" MINIMUM
GRAB BAR
3' - 4" TO VERT.
4' - 6"
B A
C K
W A
LL
SIDE WALL
59" MIN (FLOOR MOUNTED)
56" MIN (WALL HUNG)
FINISHED
FACE
(WC) ACCESSIBLE
TOILET FIXTURE
C3
G1-003
C4
G1-003
NOTE:
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
REFER TO ADA/ABA 604.8.1.1, 604.2, 604.3.1, 604.5.1, 604.5.2, 604.8.1
(GB1) CONTINUOUS
HORIZONTAL GRAB BAR
(GB4) VERTICAL GRAB BAR
FINISHED
FLOOR
(6
.4
2'
1"
M A
X
(608.2.2)
5' - 0" CLEAR
FINISHED
FACE
BACK WALL
FINISHED
FACE
(GB3) OR (GB7)
CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
(SEE FLOOR PLANS)
NOTE:
SEE E7/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
D4
AE-601
4'
O R
'-0
(S
E E
F
LO
O R
P
LA
N S
BACK WALL 1
1/
2" M
A X
S
ID
E W
A
LL
2'
6" M
IN
IM
U M
5' - 0" MINIMUM CLEAR
E Q
E Q
2'
0" M
IN
IM
U M
F2
AE-201
NOTE:
SEE ROLL-IN SHOWER DETAILS ON SHEET AE-601
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE. REFER
TO ADA/ABA FIGURE 608.2.2.
(GB3) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
E6
G1-003
E4
G1-003
FLOOR DRAIN - SEE
PLUMBING DRAWINGS
(S E
E F
LO
O
R P
LA
N
S
3'
'-0
LE
N
G T
H
S
E E
F
LO
O R
P
LA
N S
2'
0"
'-0
LE
N G
T H
(GB7) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
CLEAR FLOOR AREA
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
(WC-H) ACCESSIBLE
TOILET FIXTURE
FRONT VIEW
TOP OF SEAT
M A
X
3' - 0" MINIMUM
M A
X
M
IN
(GB1) CONTINUOUS HORIZONTAL GRAB BAR
FINISHED
FACE
(WC)
BACK WALL
(6
.4
2' - 0" 12" MIN
1' - 5"
PROVIDE BLOCKING (DASHED LINES) SEE
BLOCKING DETAILS ON SHEET AE-571
NOTE:
SEE C6/GI-003 FOR PLAN
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
E Q
E Q
4'
0"
BACK WALL
S
ID
E W
A
LL
4' - 0"
(GB6) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
NOTE:
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
SEE ROLL-IN SHOWER DETAILS ON SHEET AE-601
C8
G1-003
E8
G1-003
C7
G1-003
D4
AE-601
FINISHED FACEFINISHED FACE
HIGH POINT OF SLOPED
FLOOR SURFACE AND
EDGE OF SOLID SURFACE
WALL PANEL
EDGE OF SOLID
SURFACE WALL PANEL
FLOOR DRAIN - SEE
PLUMBING DRAWINGS
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
S
ID
E W
A
LL
NOTE:
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
REFER TO ADA/ABA 604.8.1.1, 604.2, 604.3.1, 604.5.1, 604.5.2, 604.8.1
A4
G1-003
SIDE WALL
B A
C K
W A
LL
2'
M
IN
IM
U
M
5'
M
IN
IM
U
M
C
LE
A R
FINISHED FACE
4' - 6" MIN.
59" MIN (FLOOR MOUNTED)
56" MIN (WALL HUNG)
GRAB BAR
3' - 4" TO VERTICAL
2' - 0" MINIMUM
LIGATURE-
RESISTANT
ACCESSIBLE
TOILET FIXTURE
A6
G1-003
(GB2) CONTINUOUS LIGATURE-
RESISTANT HORIZONTAL GRAB BAR
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
(WC-LR) LIGATURE-RESISTANT
ACCESSIBLE TOILET FIXTURE
FRONT VIEW
TOP OF SEAT
M A
X
1' - 5"
2' - 6" MINIMUM
M A
X
M
IN
FINISHED
FACE
(WC-LR)
BACK WALL
(6
.4
PROVIDE BLOCKING (DASHED LINES) SEE
BLOCKING DETAILS ON SHEET AE-571
(GB2) CONTINUOUS LIGATURE-
RESISTANT HORIZONTAL GRAB BAR
NOTE:
SEE A7/GI-003 FOR PLAN
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE
SIDE WALL
FINISHED FACE
4' - 0"
2'
1"
M A
X
(6
.9
3' - 0"
(GB6) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
HIGH POINT OF SLOPED
FLOOR SURFACE AND
EDGE OF SOLID
SURFACE WALL PANEL
EDGE OF SOLID
SURFACE WALL PANEL
NOTE:
SEE A8/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
4' - 0"
FINISHED
FLOOR
FINISHED FACE
BACK WALL
2'
1"
M A
X
(6
.9
NOTE:
SEE A8/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
FINISHED FACE
(GB6) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE
FINISHED FACE
EQ EQ
4' - 0"
2'
1"
M A
X
(6
.9
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE AND
CONTROLS - SEE PLUMBING
DRAWINGS
SIDE WALL
3'
0"
6'
(GB6) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
3' - 0"
HIGH POINT OF SLOPED
FLOOR SURFACE AND
EDGE OF SOLID
SURFACE WALL PANEL
EDGE OF SOLID
SURFACE WALL PANEL
1'
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
NOTE:
SEE A8/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
SIDE WALL
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE
4'-0" OR 3'-0" (SEE FLOOR PLANS)
FINISHED
FACE
(6
.4
2'
1"
M A
X
(SEE FLOOR PLANS)
3' - 0" @ 4' - 0" LENGTH
(GB3) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
HIGH POINT OF SLOPED
FLOOR SURFACE AND
EDGE OF SOLID SURFACE
WALL PANEL
(SEE FLOOR PLANS)
2' - 0" @ 3' - 0" LENGTH
NOTE:
SEE E7/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
4'-0" OR 3'-0" (SEE FLOOR PLANS)
FINISHED
FACE
SIDE WALL
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE
(6
.4
2'
1"
M A
X
(SF-LR) LIGATURE-RESISTANT
SHOWER FIXTURE AND CONTROLS
- SEE PLUMBING DRAWINGS
EQ EQ
1'
3'
0"
6'
(SEE FLOOR PLANS)
3' - 0" @ 4' - 0" LENGTH
HIGH POINT OF SLOPED
FLOOR SURFACE AND
EDGE OF SOLID SURFACE
WALL PANEL
(GB3) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
(GB7) CONTINUOUS
HORIZONTAL LIGATURE-
RESISTANT GRAB BAR
(SEE FLOOR PLANS)
2' - 0" @ 3' - 0" LENGTH
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
NOTE:
SEE E7/GI-003 FOR PLAN
SEE SHEET GI-002 FOR ACCESSORY SCHEDULE
FINISHED FLOOR
TOP OF SEAT (
9.
4)
M A
X
54" MIN
(WC-LR) LIGATURE-RESISTANT
ACCESSIBLE WATER CLOSET
SIDE VIEW
FINISHED
FACE
(WC-LR)
M
IN
40" MIN
SIDE WALL
(GB5) LIGATURE-
RESISTANT VERTICAL
GRAB BAR
PROVIDE BLOCKING (DASHED LINES) SEE
BLOCKING DETAILS ON SHEET AE-571
NOTE:
SEE A7/GI-003 FOR PLAN
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
(GB2) CONTINUOUS LIGATURE-
RESISTANT HORIZONTAL GRAB BAR
FINISHED FLOOR
TOP OF SEAT (
9.
4)
M A
X
54" MIN
(WC-H) ACCESSIBLE
TOILET FIXTURE
SIDE VIEW
FINISHED
FACE
(WC)
40" MIN
M
IN
SIDE WALL
(GB4) VERTICAL GRAB BAR
PROVIDE BLOCKING (DASHED LINES) SEE
BLOCKING DETAILS ON SHEET AE-571
NOTE:
SEE C6/GI-003 FOR PLAN
SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE
(GB1) CONTINUOUS HORIZONTAL GRAB BAR
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
C O
N S
TR
U C
TI
O N D
O C U M
EN
TS
Revisions: Drawing Title
Location
Project Title
DrawnChecked
Drawing Number
DESIGN INPATIENT MENTAL
HEALTH BUILDING 49
SHT of04/16/18
ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS
MEP + STRUCT: IMEG (FORMALLY KJWW)
CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS
COMMISSIONING: NV5 SEBESTA
ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS
564-610 o n e e ig h th in c h o n e fo o t
B A
C D
E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F E
D C
B A
97 8654321
RSJDP
FULLY SPRINKLERED
VA FORM 08-6231, OCT 1998
Date
Medical Center Director:
ARCHITECT/ENGINEERS:
Date
Project Number
Building Number
2575 KEYSTONE CROSSING
FAYETTEVILLE, AR 72703
CONSULTANTS:
ENGINEERING
SERVICE
Associate Director:
Chief of Staff:
Associate Director Patient Care Services:
Supervisory Industrial Hygienist:
Chief of Engineering Services:
/1
/2
:4
:5
A
M GI-003
ACCESSIBILITY REQUIREMENTS AND
DETAILS
12" = 1'-0"F8
ACCESSIBLE LAVATORY
12" = 1'-0"F4
PROTRUDING OBJECTS
6" = 1'-0"F6
ACCESSIBLE DRINKING FOUNTAIN
1/2" = 1'-0"C6
PLAN - ACCESSIBLE TOILET
1. WHEN SHOWERS AND/OR LOCKERS ARE PROVIDED AT LEAST ONE (NOT LESS THAN 1%) SHALL BE AVAILABLE TO
PEOPLE WITH DISABILITIES.
2. SHOWER COMPARTMENTS
A. THRESHOLDS (OR RECESSED DROPS) SHALL BE A MAXIMUM OF 1/2" AND BEVELED TO A MAXIMUM OF 1:2 (V:H).
B. SHOWER FLOOR SHALL SLOPE AT MAXIMUM 1/2" PER FOOT TO DRAIN LOCATED 6" FROM THE REAR WALL.
C. SHOWER FLOOR SURFACE SHALL BE SLIP RESISTANCE.
(REFER TO F6/GI-003)
1. DRINKING FOUNTAIN SHALL NOT ENCROACH INTO PEDESTRIAN WAYS.
2. LOCATE DRINKING FOUNTAIN IN ALCOVE NOT LESS THAN 32" WIDE AND 18" DEEP
3. PROVIDE A SPACE 27" HIGH AND 18" DEEP UNDER THE DRINKING FOUNTAIN.
4. BUBBLER CONTROL (LEVER OPERATED, ETC.) SHALL BE LOCATED WITHIN 6" OF THE FRONT OF THE DRINKING
FOUNTAIN AND WITHIN 33" ABOVE THE FLOOR.
5. BUBBLER OUTLET ORIFICE SHALL BE LOCATED WITHIN 6" OF THE FRONT OF THE DRINKING FOUNTAIN AND 36" MAXIMUM ABOVE THE FLOOR WITH THE WATER STREAM PARALLEL TO THE FRONT EDGE OF THE DRINKING
FOUNTAIN.
1. AT AREAS OF THE PROJECT THAT ARE ACCESSIBLE TO PEOPLE WITH DISABILITIES, OBJECTS WITH LEADING EDGES BETWEEN 27" AND 80" ABOVE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, CORRIDORS, ETC.
REFER TO F4/GI-003.
1. REFER TO GI-002 FOR TOILET ROOM ACCESSORIES, FIXTURES AND MOUNTING HEIGHTS.
2. REFER TO AE-401 - AE-411 FOR LOCATION AND PLACEMENT OF FIXTURES AND ACCESSORIES.
1. A MINIMUM SPACE OF 30" BY 48" IS REQUIRED TO ACCOMMODATE A WHEELCHAIR FOR FORWARD OR PARALLEL APPROACH. AREAS UNDER PROJECTING OBJECTS MAY BE USED WHEN ENOUGH KNEE SPACE IS AVAILABLE.
2. FORWARD REACH
A. MAXIMUM 48" HIGH UNOBSTRUCTED REACH PERMITTED FOR FORWARD
APPROACH.
B. MINIMUM 15" LOW REACH PERMITTED FOR FORWARD APPROACH.
C. MAXIMUM 44" HIGH REACH PERMITTED WHEN REACH IS OVER AN
OBSTRUCTION BETWEEN 20" AND 25" WIDE.
3. SIDE REACH
A. MAXIMUM 48" HIGH REACH UNOBSTRUCTED REACH PERMITTED FOR
PARALLEL APPROACH.
B. MINIMUM 15" LOW REACH PERMITTED FOR PARALLEL APPROACH
C. MAXIMUM 46" HIGH REACH PERMITTED WHEN REACH IS OVER AN
OBSTRUCTION BETWEEN 10" AND 24" WIDE.
4. ADDITIONAL MANEUVERING CLEARANCES FOR ALCOVES
A. WHEN FORWARD APPROACH INTO ALCOVE EXCEEDS 24" PROVIDE A 36" WIDTH.
B. WHEN PARALLEL APPROACH INTO ALCOVE EXCEEDS 15" PROVIDE A 60" LENGTH.
1. THE SURFACE OF THE FLOOR SHALL BE SLIP-RESISTANT.
1. ALL DESIGNATED PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO PEOPLE WITH
DISABILITIES AS RECOGNIZED BY ADA/ABA.
1. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE MOUNTED 34" TO 44" ABOVE THE FLOOR AND BE OPERABLE
WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE.
2. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR
INTERIOR DOORS.
3. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED
SURFACE.
4. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE DOOR AT 90 DEGREES TO
THE CLOSED POSITION.
5. ONE DOOR OF A PAIR OF DOORS SHALL MEET THE MINIMUM WIDTH REQUIREMENTS.
6. MAXIMUM HEIGHT OF THRESHOLD SHALL BE 1/2". MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4" WITH A MAXIMUM
LEVEL OF 45 DEGREE.
7. THE SPACE BETWEEN TWO CONSECUTIVE DOORS (VESTIBULE) SHALL PROVIDE A MINIMUM OF 48 INCHES CLEAR DEPTH BETWEEN THE OPEN AND SECOND CLOSED DOOR. BOTH DOORS AT A VESTIBULE SHALL SWING IN THE SAME
DIRECTION, OR AWAY FROM THE SPACE BETWEEN THEM.
8. EXIT DOORS SHALL SWING IN DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA OR WHEN SERVING
AN OCCUPANT LOAD OF 50 OR MORE.
9. WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE.
10. THE WIDTH OF THE DOOR'S "CLEAR AREA" ON THE SWING SIDE OF THE DOOR SHALL EXTEND 24 INCHES PAST STRIKE JAMB FOR EXTERIOR DOORS AND 18 INCHES PAST STRIKE JAMB FOR INTERIOR DOORS.
11. THERE SHALL BE A CLEAR AREA ON EACH SIDE OF THE DOOR, 60 INCHES DEEP IN THE DIRECTION OF THE DOOR
SWING AND 44 INCHES DEEP IN THE OPPOSITE DIRECTION OF THE DOOR SWING.
1. WHERE SANITARY FACILITIES ARE LOCATED ON ACCESSIBLE FLOORS OF A BUILDING, THEY SHALL BE MADE
ACCESSIBLE TO PEOPLE WITH DISABILITIES
2. ENTRY TO SANITARY FACILITIES
A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE.
B. DOORWAYS SHALL HAVE 32" CLEAR OPENING.
C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44"
SPACE WHEN DOOR SWINGS AWAY FROM APPROACH.
3. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND BACK OF WATER CLOSET. REFER TO F7/A-571 FOR BLOCKING.
A. GRAB BARS SHALL BE A MAXIMUM 36" ABOVE AND PARALLEL TO THE FLOOR.
B. SIDE GRAB BARS SHALL BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT
BACK SHALL BE 36" LONG.
C. DIAMETER OF GRAB BARS SHALL BE 1 1/4" TO 1 1/2".
D. PROVIDE 1 1/2" CLEARANCE BETWEEN GRAB BARS AND PARTITIONS.
E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, AND ETC.) SHALL BE DESIGNED TO
SUPPORT A 250 POUND LOAD.
F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
4. LAVATORIES (REFER TO F8/GI-003).
A. PROVIDE A CLEAR FLOOR SPACE OF 30" BY 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH.
B. PROVIDE A CLEAR SPACE BENEATH THE LAVATORY 29" HIGH BY 30" WIDE BY 8" DEEP AT THE TOP AND 9" HIGH
BY 30" WIDE BY 17" DEEP AT THE BOTTOM.
C. HOT AND COLD WATER SUPPLY AND VALVE AND DRAIN PIPES UNDER LAVATORY SHALL BE INSULATED OR
COVERED AND BE FREE OF SHARP OR ABRASIVE SURFACES.
D. FAUCET CONTROLS AND OPERATING MECHANISMS (OPERABLE WITH ONE HAND) SHALL BE OF THE TYPE NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING OF THE WRISTS, OR AN OPERATING FORCE
EXCEEDING 5 POUNDS.
E. SELF CLOSING VALVES PERMITTED IF FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.
F. BOTTOM EDGE OF MIRROR SHALL BE 40 INCHES AFF MAXIMUM.
G. A CLEAR SPACE BENEATH LAVATORIES 29 INCHES HIGH BY 30 INCHES WIDE BY 8 INCHES DEEP AT BOTTOM
FROM FRONT OF LAVATORY. HOT \ WATER DRAIN PIPES SHALL BE INSULATED.
6. WATER CLOSETS.
A. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17 AND 19 INCHES.
B. FLUSH CONTROLS SHALL BE OPERABLE BY AN OSCILLATING HANDLE WITH A MAXIMUM FORCE OF 3 POUNDS, AND SHALL BE ON THE WIDE SIDE OF THE TOILET STALL.
C. PROVIDE A 28 INCH "CLEAR AREA" BETWEEN TOILET FIXTURE AND SINK FIXTURE AND 32 INCH "CLEAR AREA"
BETWEEN TOILET FIXTURE AND WALL.
7. TOILET ROOM ACCESSORIES (WHERE PROVIDED)
A. BOTTOM EDGE OF MIRRORS SHALL BE NO HIGHER THAN 40" FROM THE FLOOR.
B. TOILET TISSUE DISPENSERS SHALL BE MOUNTED WITHIN 7"-9" FROM THE FRONT EDGE OF THE TOILET SEAT.
C. OPERATING PARTS OF DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN
SLOTS, ETC.) SHALL BE WITHIN 40" FROM THE FLOOR.
GENERAL ACCESSIBILITY NOTES
CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS
FLOORS
ENTRANCES, DOORS AND DOORWAYS
DOORS
SANITARY FACILITIES
SHOWER AND LOCKERS
DRINKING FOUNTAINS
PROTRUDING OBJECTS
G-111G-111
FULL SCALE
0 1" 2" 3"
6" = 1'-0"
1" 2" 4" 6"
0 2'
3/4" = 1'-0"
6" 1' 4'
1/2" = 1'-0"
1' 2' 4' 6'
1/2" = 1'-0"E3
ELEVATIONS - ACCESSIBLE SHOWER STALL
1/2" = 1'-0"E7
ACCESSIBLE SHOWER STALL (PATIENT)
1/2" = 1'-0"C3
ELEVATIONS - ACCESSIBLE TOILET
1/2" = 1'-0"A8
STANDARD SHOWER STALL
1/2" = 1'-0"A7
PLAN - ACCESSIBLE TOILET (PAT RM)
1/2" = 1'-0"A4
ELEVATIONS - ACCESSIBLE TOILET (PAT RM)
1/2" = 1'-0"C7
ELEVATION - STANDARD SHOWER STALL
1/2" = 1'-0"C8
ELEVATION - STANDARD SHOWER STALL
1/2" = 1'-0"E8
ELEVATION - STANDARD SHOWER STALL
1/2" = 1'-0"E4
ELEVATIONS - ACCESSIBLE SHOWER STALL
1/2" = 1'-0"E6
ELEVATIONS - ACCESSIBLE SHOWER STALL
1/2" = 1'-0"A6
ELEVATIONS - ACCESSIBLE TOILET (PAT RM)
1/2" = 1'-0"C4
ELEVATIONS - ACCESSIBLE TOILET