36C25618B0678-0005005.pdf

PDF 216 KB Posted

Attached to
FAV-New Mental Health Building-Solicitation
Solicitation number
36C25618B0678
Issued by

About this file

36C25618B0678 0005 Attch E missing GI-003 Sheet 10262018 01.pdf

View the file

Other files

File Type Posted
36C25618B0678-0006001.pdf PDF
36C25618B0678-0006000.docx DOCX document
36C25618B0678-0005000.docx DOCX document
36C25618B0678-0005006.pdf PDF
36C25618B0678-0005002.pdf PDF
36C25618B0678-0005001.pdf PDF
36C25618B0678-0005004.pdf PDF
36C25618B0678-0005003.pdf PDF
36C25618B0678-0004000.docx DOCX document
36C25618B0678-0003000.docx DOCX document
36C25618B0678-0002011.docx DOCX document
36C25618B0678-019.pdf PDF
36C25618B0678-016.docx DOCX document
36C25618B0678-017.pdf PDF
36C25618B0678-018.pdf PDF
36C25618B0678-002.docx DOCX document
36C25618B0678-0001001.pdf PDF
36C25618B0678-0001000.docx DOCX document
36C25618B0678-001.docx DOCX document
36C25618B0678-000.docx DOCX document
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLEARANCE REQUIREMENTS AND PROTECTIVE PANEL AT LAVATORY

CLEAR

FLOOR

SPACE

1. BOTTOM OF PANEL SHALL BE AS HIGH AS POSSIBLE AND

STILL CONCEAL AND PROTECT PIPES.

2. PLACE LAVATORY BOWL AS FAR FORWARD AS POSSIBLE

AND CUT OUT PIPE PROTECTION PANEL AROUND BOWL.

3. REFER TO ADA/ABA 603.3

M

IN

9" M

IN

M

IN

M A

X

M A

X

KNEE CLEARANCE

8" MIN

TOE CLEARANCE

6" MAX

17" MIN

30" MIN

M

IN

D E

P T

H

M

IN

M A

X CLEAR

FLOOR

SPACE

30" MIN

M

IN

D E

P T

H

M

IN

M A

X

STANDARD LAVATORY STANDARD LAVATORY LIGATURE-RESISTANT

LAVATORY

OBJECT

NOTES:

1. OBJECTS PROJECTING FROM WALLS WHOSE

LEADING EDGES ARE BETWEEN 27" AND 80"

ABOVE FINISH FLOOR SHALL NOT

PROTRUDE MORE THAN 4" INTO WALKS,

WALLS, CORRIDORS, PASSAGEWAYS, OR

AISLES.

2. OBJECTS WHOSE LEADING EDGES ARE AT

OR BELOW 27" ABOVE FINISH FLOOR, MAY

PROTRUDE ANY AMOUNT.

3. WALKS, HALLS, CORRIDORS, PASSAGEWAYS,

AISLES, OR OTHER CIRCULATING SPACES

SHALL HAVE A MINIMUM 80" CLEAR

HEADROOM.

2' -3

B

E

LO

W

4" MAXIMUM

T H

A N

'-3

H

IG

H E

R

6' -8

M

IN

IM

U M

ANY AMOUNT

OBJECT

6" MIN. 6" MIN.

18" MIN,

24" MAX

63" MIN

M

IN

M A

X

ALCOVES SHALL BE A MINIMUM

18" DEEP. IN ADDITION, ALCOVES SHALL

BE A MINIMUM 63" WIDE AND A MINIMUM

OF 32" WIDE FOR A SINGLE FOUNTAIN.

COORDINATE ALCOVE SIZE WITH THE SIZE

AND NUMBER OF DRINKING FOUNTAINS

PROVIDED FOR REQUIRED CLEARANCES.

IF CONFLICT OCCURS,CONTRACTOR

SHALL SUBMIT RECOMMENDATION FOR

ARCHITECT'S REVIEW AND APPROVAL

IF ALCOVE IS GREATER THAN 24" DEEP,

THEN ALCOVE SHALL BE A MINIMUM OF

36" WIDE.

RECESSED FOUNTAINS:

1.

2.

ACCESSIBLE

NOTE:

DRINKING FOUNTAINS SHALL BE INSTALLED IN ACCORDANCE

WITH APPLICABLE ADA/ABA GUIDELINES.

STANDARD

5'

M

IN

IM

U

M

C

LE

A R

3'

0" M

IN

IM

U M

6" M

A X

IM

U

M

2' - 0" MINIMUM

GRAB BAR

3' - 4" TO VERT.

4' - 6"

B A

C K

W A

LL

SIDE WALL

59" MIN (FLOOR MOUNTED)

56" MIN (WALL HUNG)

FINISHED

FACE

(WC) ACCESSIBLE

TOILET FIXTURE

C3

G1-003

C4

G1-003

NOTE:

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

REFER TO ADA/ABA 604.8.1.1, 604.2, 604.3.1, 604.5.1, 604.5.2, 604.8.1

(GB1) CONTINUOUS

HORIZONTAL GRAB BAR

(GB4) VERTICAL GRAB BAR

FINISHED

FLOOR

(6

.4

2'

1"

M A

X

(608.2.2)

5' - 0" CLEAR

FINISHED

FACE

BACK WALL

FINISHED

FACE

(GB3) OR (GB7)

CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

(SEE FLOOR PLANS)

NOTE:

SEE E7/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

D4

AE-601

4'

O R

'-0

(S

E E

F

LO

O R

P

LA

N S

BACK WALL 1

1/

2" M

A X

S

ID

E W

A

LL

2'

6" M

IN

IM

U M

5' - 0" MINIMUM CLEAR

E Q

E Q

2'

0" M

IN

IM

U M

F2

AE-201

NOTE:

SEE ROLL-IN SHOWER DETAILS ON SHEET AE-601

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE. REFER

TO ADA/ABA FIGURE 608.2.2.

(GB3) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

E6

G1-003

E4

G1-003

FLOOR DRAIN - SEE

PLUMBING DRAWINGS

(S E

E F

LO

O

R P

LA

N

S

3'

'-0

LE

N

G T

H

S

E E

F

LO

O R

P

LA

N S

2'

0"

'-0

LE

N G

T H

(GB7) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

CLEAR FLOOR AREA

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

(WC-H) ACCESSIBLE

TOILET FIXTURE

FRONT VIEW

TOP OF SEAT

M A

X

3' - 0" MINIMUM

M A

X

M

IN

(GB1) CONTINUOUS HORIZONTAL GRAB BAR

FINISHED

FACE

(WC)

BACK WALL

(6

.4

2' - 0" 12" MIN

1' - 5"

PROVIDE BLOCKING (DASHED LINES) SEE

BLOCKING DETAILS ON SHEET AE-571

NOTE:

SEE C6/GI-003 FOR PLAN

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

E Q

E Q

4'

0"

BACK WALL

S

ID

E W

A

LL

4' - 0"

(GB6) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

NOTE:

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

SEE ROLL-IN SHOWER DETAILS ON SHEET AE-601

C8

G1-003

E8

G1-003

C7

G1-003

D4

AE-601

FINISHED FACEFINISHED FACE

HIGH POINT OF SLOPED

FLOOR SURFACE AND

EDGE OF SOLID SURFACE

WALL PANEL

EDGE OF SOLID

SURFACE WALL PANEL

FLOOR DRAIN - SEE

PLUMBING DRAWINGS

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

S

ID

E W

A

LL

NOTE:

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

REFER TO ADA/ABA 604.8.1.1, 604.2, 604.3.1, 604.5.1, 604.5.2, 604.8.1

A4

G1-003

SIDE WALL

B A

C K

W A

LL

2'

M

IN

IM

U

M

5'

M

IN

IM

U

M

C

LE

A R

FINISHED FACE

4' - 6" MIN.

59" MIN (FLOOR MOUNTED)

56" MIN (WALL HUNG)

GRAB BAR

3' - 4" TO VERTICAL

2' - 0" MINIMUM

LIGATURE-

RESISTANT

ACCESSIBLE

TOILET FIXTURE

A6

G1-003

(GB2) CONTINUOUS LIGATURE-

RESISTANT HORIZONTAL GRAB BAR

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

(WC-LR) LIGATURE-RESISTANT

ACCESSIBLE TOILET FIXTURE

FRONT VIEW

TOP OF SEAT

M A

X

1' - 5"

2' - 6" MINIMUM

M A

X

M

IN

FINISHED

FACE

(WC-LR)

BACK WALL

(6

.4

PROVIDE BLOCKING (DASHED LINES) SEE

BLOCKING DETAILS ON SHEET AE-571

(GB2) CONTINUOUS LIGATURE-

RESISTANT HORIZONTAL GRAB BAR

NOTE:

SEE A7/GI-003 FOR PLAN

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE

SIDE WALL

FINISHED FACE

4' - 0"

2'

1"

M A

X

(6

.9

3' - 0"

(GB6) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

HIGH POINT OF SLOPED

FLOOR SURFACE AND

EDGE OF SOLID

SURFACE WALL PANEL

EDGE OF SOLID

SURFACE WALL PANEL

NOTE:

SEE A8/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

4' - 0"

FINISHED

FLOOR

FINISHED FACE

BACK WALL

2'

1"

M A

X

(6

.9

NOTE:

SEE A8/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

FINISHED FACE

(GB6) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE

FINISHED FACE

EQ EQ

4' - 0"

2'

1"

M A

X

(6

.9

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE AND

CONTROLS - SEE PLUMBING

DRAWINGS

SIDE WALL

3'

0"

6'

(GB6) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

3' - 0"

HIGH POINT OF SLOPED

FLOOR SURFACE AND

EDGE OF SOLID

SURFACE WALL PANEL

EDGE OF SOLID

SURFACE WALL PANEL

1'

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

NOTE:

SEE A8/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

SIDE WALL

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE

4'-0" OR 3'-0" (SEE FLOOR PLANS)

FINISHED

FACE

(6

.4

2'

1"

M A

X

(SEE FLOOR PLANS)

3' - 0" @ 4' - 0" LENGTH

(GB3) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

HIGH POINT OF SLOPED

FLOOR SURFACE AND

EDGE OF SOLID SURFACE

WALL PANEL

(SEE FLOOR PLANS)

2' - 0" @ 3' - 0" LENGTH

NOTE:

SEE E7/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

4'-0" OR 3'-0" (SEE FLOOR PLANS)

FINISHED

FACE

SIDE WALL

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE

(6

.4

2'

1"

M A

X

(SF-LR) LIGATURE-RESISTANT

SHOWER FIXTURE AND CONTROLS

- SEE PLUMBING DRAWINGS

EQ EQ

1'

3'

0"

6'

(SEE FLOOR PLANS)

3' - 0" @ 4' - 0" LENGTH

HIGH POINT OF SLOPED

FLOOR SURFACE AND

EDGE OF SOLID SURFACE

WALL PANEL

(GB3) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

(GB7) CONTINUOUS

HORIZONTAL LIGATURE-

RESISTANT GRAB BAR

(SEE FLOOR PLANS)

2' - 0" @ 3' - 0" LENGTH

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

NOTE:

SEE E7/GI-003 FOR PLAN

SEE SHEET GI-002 FOR ACCESSORY SCHEDULE

FINISHED FLOOR

TOP OF SEAT (

9.

4)

M A

X

54" MIN

(WC-LR) LIGATURE-RESISTANT

ACCESSIBLE WATER CLOSET

SIDE VIEW

FINISHED

FACE

(WC-LR)

M

IN

40" MIN

SIDE WALL

(GB5) LIGATURE-

RESISTANT VERTICAL

GRAB BAR

PROVIDE BLOCKING (DASHED LINES) SEE

BLOCKING DETAILS ON SHEET AE-571

NOTE:

SEE A7/GI-003 FOR PLAN

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

(GB2) CONTINUOUS LIGATURE-

RESISTANT HORIZONTAL GRAB BAR

FINISHED FLOOR

TOP OF SEAT (

9.

4)

M A

X

54" MIN

(WC-H) ACCESSIBLE

TOILET FIXTURE

SIDE VIEW

FINISHED

FACE

(WC)

40" MIN

M

IN

SIDE WALL

(GB4) VERTICAL GRAB BAR

PROVIDE BLOCKING (DASHED LINES) SEE

BLOCKING DETAILS ON SHEET AE-571

NOTE:

SEE C6/GI-003 FOR PLAN

SEE SHEET GI-002 FOR LOCATION OF ACCESSORIES AND ACCESSORY SCHEDULE

(GB1) CONTINUOUS HORIZONTAL GRAB BAR

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

C O

N S

TR

U C

TI

O N D

O C U M

EN

TS

Revisions: Drawing Title

Location

Project Title

DrawnChecked

Drawing Number

DESIGN INPATIENT MENTAL

HEALTH BUILDING 49

SHT of04/16/18

ARCHITECT: MICHAEL ROTH AND ASSOCIATESCONSULTANT ARCHITECT: JACOBS

MEP + STRUCT: IMEG (FORMALLY KJWW)

CIVIL ENGINEER: MCCLELLAND CONSULTING ENGINEERS

COMMISSIONING: NV5 SEBESTA

ESTIMATOR: MIDDLETON CONSTRUCTION CONSULTANTS

564-610 o n e e ig h th in c h o n e fo o t

B A

C D

E F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

1 2 3 4 5 6 87 9

F E

D C

B A

97 8654321

RSJDP

FULLY SPRINKLERED

VA FORM 08-6231, OCT 1998

Date

Medical Center Director:

ARCHITECT/ENGINEERS:

Date

Project Number

Building Number

2575 KEYSTONE CROSSING

FAYETTEVILLE, AR 72703

CONSULTANTS:

ENGINEERING

SERVICE

Associate Director:

Chief of Staff:

Associate Director Patient Care Services:

Supervisory Industrial Hygienist:

Chief of Engineering Services:

/1

/2

:4

:5

A

M GI-003

ACCESSIBILITY REQUIREMENTS AND

DETAILS

12" = 1'-0"F8

ACCESSIBLE LAVATORY

12" = 1'-0"F4

PROTRUDING OBJECTS

6" = 1'-0"F6

ACCESSIBLE DRINKING FOUNTAIN

1/2" = 1'-0"C6

PLAN - ACCESSIBLE TOILET

1. WHEN SHOWERS AND/OR LOCKERS ARE PROVIDED AT LEAST ONE (NOT LESS THAN 1%) SHALL BE AVAILABLE TO

PEOPLE WITH DISABILITIES.

2. SHOWER COMPARTMENTS

A. THRESHOLDS (OR RECESSED DROPS) SHALL BE A MAXIMUM OF 1/2" AND BEVELED TO A MAXIMUM OF 1:2 (V:H).

B. SHOWER FLOOR SHALL SLOPE AT MAXIMUM 1/2" PER FOOT TO DRAIN LOCATED 6" FROM THE REAR WALL.

C. SHOWER FLOOR SURFACE SHALL BE SLIP RESISTANCE.

(REFER TO F6/GI-003)

1. DRINKING FOUNTAIN SHALL NOT ENCROACH INTO PEDESTRIAN WAYS.

2. LOCATE DRINKING FOUNTAIN IN ALCOVE NOT LESS THAN 32" WIDE AND 18" DEEP

3. PROVIDE A SPACE 27" HIGH AND 18" DEEP UNDER THE DRINKING FOUNTAIN.

4. BUBBLER CONTROL (LEVER OPERATED, ETC.) SHALL BE LOCATED WITHIN 6" OF THE FRONT OF THE DRINKING

FOUNTAIN AND WITHIN 33" ABOVE THE FLOOR.

5. BUBBLER OUTLET ORIFICE SHALL BE LOCATED WITHIN 6" OF THE FRONT OF THE DRINKING FOUNTAIN AND 36" MAXIMUM ABOVE THE FLOOR WITH THE WATER STREAM PARALLEL TO THE FRONT EDGE OF THE DRINKING

FOUNTAIN.

1. AT AREAS OF THE PROJECT THAT ARE ACCESSIBLE TO PEOPLE WITH DISABILITIES, OBJECTS WITH LEADING EDGES BETWEEN 27" AND 80" ABOVE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, CORRIDORS, ETC.

REFER TO F4/GI-003.

1. REFER TO GI-002 FOR TOILET ROOM ACCESSORIES, FIXTURES AND MOUNTING HEIGHTS.

2. REFER TO AE-401 - AE-411 FOR LOCATION AND PLACEMENT OF FIXTURES AND ACCESSORIES.

1. A MINIMUM SPACE OF 30" BY 48" IS REQUIRED TO ACCOMMODATE A WHEELCHAIR FOR FORWARD OR PARALLEL APPROACH. AREAS UNDER PROJECTING OBJECTS MAY BE USED WHEN ENOUGH KNEE SPACE IS AVAILABLE.

2. FORWARD REACH

A. MAXIMUM 48" HIGH UNOBSTRUCTED REACH PERMITTED FOR FORWARD

APPROACH.

B. MINIMUM 15" LOW REACH PERMITTED FOR FORWARD APPROACH.

C. MAXIMUM 44" HIGH REACH PERMITTED WHEN REACH IS OVER AN

OBSTRUCTION BETWEEN 20" AND 25" WIDE.

3. SIDE REACH

A. MAXIMUM 48" HIGH REACH UNOBSTRUCTED REACH PERMITTED FOR

PARALLEL APPROACH.

B. MINIMUM 15" LOW REACH PERMITTED FOR PARALLEL APPROACH

C. MAXIMUM 46" HIGH REACH PERMITTED WHEN REACH IS OVER AN

OBSTRUCTION BETWEEN 10" AND 24" WIDE.

4. ADDITIONAL MANEUVERING CLEARANCES FOR ALCOVES

A. WHEN FORWARD APPROACH INTO ALCOVE EXCEEDS 24" PROVIDE A 36" WIDTH.

B. WHEN PARALLEL APPROACH INTO ALCOVE EXCEEDS 15" PROVIDE A 60" LENGTH.

1. THE SURFACE OF THE FLOOR SHALL BE SLIP-RESISTANT.

1. ALL DESIGNATED PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO PEOPLE WITH

DISABILITIES AS RECOGNIZED BY ADA/ABA.

1. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE MOUNTED 34" TO 44" ABOVE THE FLOOR AND BE OPERABLE

WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE.

2. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR

INTERIOR DOORS.

3. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED

SURFACE.

4. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE DOOR AT 90 DEGREES TO

THE CLOSED POSITION.

5. ONE DOOR OF A PAIR OF DOORS SHALL MEET THE MINIMUM WIDTH REQUIREMENTS.

6. MAXIMUM HEIGHT OF THRESHOLD SHALL BE 1/2". MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4" WITH A MAXIMUM

LEVEL OF 45 DEGREE.

7. THE SPACE BETWEEN TWO CONSECUTIVE DOORS (VESTIBULE) SHALL PROVIDE A MINIMUM OF 48 INCHES CLEAR DEPTH BETWEEN THE OPEN AND SECOND CLOSED DOOR. BOTH DOORS AT A VESTIBULE SHALL SWING IN THE SAME

DIRECTION, OR AWAY FROM THE SPACE BETWEEN THEM.

8. EXIT DOORS SHALL SWING IN DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA OR WHEN SERVING

AN OCCUPANT LOAD OF 50 OR MORE.

9. WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE.

10. THE WIDTH OF THE DOOR'S "CLEAR AREA" ON THE SWING SIDE OF THE DOOR SHALL EXTEND 24 INCHES PAST STRIKE JAMB FOR EXTERIOR DOORS AND 18 INCHES PAST STRIKE JAMB FOR INTERIOR DOORS.

11. THERE SHALL BE A CLEAR AREA ON EACH SIDE OF THE DOOR, 60 INCHES DEEP IN THE DIRECTION OF THE DOOR

SWING AND 44 INCHES DEEP IN THE OPPOSITE DIRECTION OF THE DOOR SWING.

1. WHERE SANITARY FACILITIES ARE LOCATED ON ACCESSIBLE FLOORS OF A BUILDING, THEY SHALL BE MADE

ACCESSIBLE TO PEOPLE WITH DISABILITIES

2. ENTRY TO SANITARY FACILITIES

A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE.

B. DOORWAYS SHALL HAVE 32" CLEAR OPENING.

C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44"

SPACE WHEN DOOR SWINGS AWAY FROM APPROACH.

3. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND BACK OF WATER CLOSET. REFER TO F7/A-571 FOR BLOCKING.

A. GRAB BARS SHALL BE A MAXIMUM 36" ABOVE AND PARALLEL TO THE FLOOR.

B. SIDE GRAB BARS SHALL BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT

BACK SHALL BE 36" LONG.

C. DIAMETER OF GRAB BARS SHALL BE 1 1/4" TO 1 1/2".

D. PROVIDE 1 1/2" CLEARANCE BETWEEN GRAB BARS AND PARTITIONS.

E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, AND ETC.) SHALL BE DESIGNED TO

SUPPORT A 250 POUND LOAD.

F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.

4. LAVATORIES (REFER TO F8/GI-003).

A. PROVIDE A CLEAR FLOOR SPACE OF 30" BY 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH.

B. PROVIDE A CLEAR SPACE BENEATH THE LAVATORY 29" HIGH BY 30" WIDE BY 8" DEEP AT THE TOP AND 9" HIGH

BY 30" WIDE BY 17" DEEP AT THE BOTTOM.

C. HOT AND COLD WATER SUPPLY AND VALVE AND DRAIN PIPES UNDER LAVATORY SHALL BE INSULATED OR

COVERED AND BE FREE OF SHARP OR ABRASIVE SURFACES.

D. FAUCET CONTROLS AND OPERATING MECHANISMS (OPERABLE WITH ONE HAND) SHALL BE OF THE TYPE NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING OF THE WRISTS, OR AN OPERATING FORCE

EXCEEDING 5 POUNDS.

E. SELF CLOSING VALVES PERMITTED IF FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.

F. BOTTOM EDGE OF MIRROR SHALL BE 40 INCHES AFF MAXIMUM.

G. A CLEAR SPACE BENEATH LAVATORIES 29 INCHES HIGH BY 30 INCHES WIDE BY 8 INCHES DEEP AT BOTTOM

FROM FRONT OF LAVATORY. HOT \ WATER DRAIN PIPES SHALL BE INSULATED.

6. WATER CLOSETS.

A. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17 AND 19 INCHES.

B. FLUSH CONTROLS SHALL BE OPERABLE BY AN OSCILLATING HANDLE WITH A MAXIMUM FORCE OF 3 POUNDS, AND SHALL BE ON THE WIDE SIDE OF THE TOILET STALL.

C. PROVIDE A 28 INCH "CLEAR AREA" BETWEEN TOILET FIXTURE AND SINK FIXTURE AND 32 INCH "CLEAR AREA"

BETWEEN TOILET FIXTURE AND WALL.

7. TOILET ROOM ACCESSORIES (WHERE PROVIDED)

A. BOTTOM EDGE OF MIRRORS SHALL BE NO HIGHER THAN 40" FROM THE FLOOR.

B. TOILET TISSUE DISPENSERS SHALL BE MOUNTED WITHIN 7"-9" FROM THE FRONT EDGE OF THE TOILET SEAT.

C. OPERATING PARTS OF DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN

SLOTS, ETC.) SHALL BE WITHIN 40" FROM THE FLOOR.

GENERAL ACCESSIBILITY NOTES

CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS

FLOORS

ENTRANCES, DOORS AND DOORWAYS

DOORS

SANITARY FACILITIES

SHOWER AND LOCKERS

DRINKING FOUNTAINS

PROTRUDING OBJECTS

G-111G-111

FULL SCALE

0 1" 2" 3"

6" = 1'-0"

1" 2" 4" 6"

0 2'

3/4" = 1'-0"

6" 1' 4'

1/2" = 1'-0"

1' 2' 4' 6'

1/2" = 1'-0"E3

ELEVATIONS - ACCESSIBLE SHOWER STALL

1/2" = 1'-0"E7

ACCESSIBLE SHOWER STALL (PATIENT)

1/2" = 1'-0"C3

ELEVATIONS - ACCESSIBLE TOILET

1/2" = 1'-0"A8

STANDARD SHOWER STALL

1/2" = 1'-0"A7

PLAN - ACCESSIBLE TOILET (PAT RM)

1/2" = 1'-0"A4

ELEVATIONS - ACCESSIBLE TOILET (PAT RM)

1/2" = 1'-0"C7

ELEVATION - STANDARD SHOWER STALL

1/2" = 1'-0"C8

ELEVATION - STANDARD SHOWER STALL

1/2" = 1'-0"E8

ELEVATION - STANDARD SHOWER STALL

1/2" = 1'-0"E4

ELEVATIONS - ACCESSIBLE SHOWER STALL

1/2" = 1'-0"E6

ELEVATIONS - ACCESSIBLE SHOWER STALL

1/2" = 1'-0"A6

ELEVATIONS - ACCESSIBLE TOILET (PAT RM)

1/2" = 1'-0"C4

ELEVATIONS - ACCESSIBLE TOILET

File details come from the government source that posted it.