Fiber Map Combined 08.28.pdf
PDF 3 MB Posted
- Solicitation number
- 36C25526Q0243-1
About this file
This document is a collection of architectural floor plans and site layouts for a federal facility complex located at the Waterman, Edgemoor, and Kellogg sites.
The document comprises detailed floor plans for multiple buildings (Buildings 1-6, 16, 19, 26, and 61) showing ground and first-floor layouts with room designations, dimensions, and functional areas. The facility includes administrative support spaces, long-term care units, procedural/ancillary areas, mental health services, acute inpatient units, ambulatory services, and maintenance operations. Key rooms identified across the various buildings include offices, storage areas, medical examination rooms, conference spaces, break rooms, mechanical and electrical rooms, communication closets, and specialized medical care areas. The plans also indicate connections between buildings through labeled room references (e.g., "To Rm 011-19," "To Rm 102-3") facilitating navigation through the complex. A site plan on page 1 shows the relative positioning of all buildings with parking lot numbers and a color-coded legend identifying building types by function. An equipment schedule on page 11 references fiber optic infrastructure specifications (6 pair OM1 62.5 micron multimode fiber) for connectivity throughout the facility. The drawings are prepared by Indus Systems, Inc., with architectural firm Howard + Helmer noted as the project lead (Project No. 11216.00). All plans are drawn to scale with directional compass indicators and coordinate references for precise spatial orientation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25526Q0243 0003.pdf | ||
| 26-603A Floor Plans Bldg Info 08.28.pdf | ||
| 36C25526Q0243 0002.pdf | ||
| 36C25526Q0243 PA System RFI Responses.xlsx | XLSX spreadsheet | |
| Life Safety Drawing Campus Wide 08.28.pdf | ||
| RJDVAMC Floor Plans 2022.pdf | ||
| B60A Floor Plans.pdf | ||
| 36C25526Q0243 0001.pdf | ||
| 26-603A Floor Plans.pdf | ||
| B26 Floor Plans.pdf | ||
| 36C25526Q0243-1.pdf | ||
| Wage Determination by reference.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WATERMAN
B U C K L E Y
E D G E M O O R
KELLOGG
xx Building number
Parking lot number
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Oval Main fiber hub Box # 6 pair, OM1 62.5 micron, single mode
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line Goes from ground floor to 1st floor for termination
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line Rm 015-2 (Panel #6) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 multi mode fiber
VHAWICOlsonD Line To
VHAWICOlsonD Sticky Note Rm 010-1
VHAWICOlsonD Text Box To Rm 010-1
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Text Box
TO RM
011-19
VHAWICOlsonD Text Box Rm 015-2 (Panel #6) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 multi mode fiber
Rectangle Main fiber hub
VHAWICOlsonD Line To Rm 050-26
VHAWICOlsonD Line
VHAWICOlsonD Line To Rm 010-1
VHAWICOlsonD Line
VHAWICOlsonD Text Box To Rm 050-26
VHAWICOlsonD Text Box To Rm 011-19
VHAWICOlsonD Rectangle Rm 009C-4 (Panel #9) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line To rm
VHAWICOlsonD Sticky Note To Rm 001B-34 / From A107-60
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Text Box To Rm 001B-34
VHAWICOlsonD Text Box From 113A-60
Rm 100A-5 (Panel #13) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line To BLDG 7
VHAWICOlsonD Line To BLDG 6
VHAWICOlsonD Text Box To Rm 002-6
VHAWICOlsonD Text Box To Rm 006B-7
Rm 006B-7 (Panel #14) 12 terminations with LC type connectors on 1 existing 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line
VHAWICOlsonD Line To BLDG 5
VHAWICOlsonD Line To BLDG 16
VHAWICOlsonD Text Box To Rm 100A-5
VHAWICOlsonD
To Rm 108-16
Rm 006B-7 (Panel #14) 12 terminations with LC type connectors on 1 existing 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line
VHAWICOlsonD Line To BLDG 5
VHAWICOlsonD
To Rm 100A-5
Rm 108-16 (Panel #11) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line
VHAWICOlsonD Line To BLDG 6
VHAWICOlsonD Line To BLDG 60
VHAWICOlsonD Text Box TO Rm 113A-60
VHAWICOlsonD
To Rm 002-6
Rm 011-19 (Panel #5) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 multimode 62.5 fiber
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line To / From BLDG 2
VHAWICOlsonD Text Box To Rm 015-2
VHAWICOlsonD Text Box Rm 011-19 (Panel #5) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 multimode 62.5 fiber
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD
TO RM 102-3 DEMARC
EQUIPMENT SCHEDULE
ITEM DESCRIPTION
SUPPLIED INSTALLED REMARKS
EQUIPMENT SCHEDULE NOTES
EQUIPMENT SCHEDULE GENERAL NOTES
HOWARD + HELMER
project no.
11216.00
9-11-2015REVISE OFFICES TO EXAM ROOMS
1-12-2016REVISE NURSE STATIONS
Fiber location 6 pair OM1
62.5 micron
VHAWICOlsonD Highlight
VHAWICOlsonD Highlight
VHAWICOlsonD Line Rm 024-29 12 (Panel #3) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD
To Rm 050-26
Rm 050-26 (Panel #2) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line To Rm 102-3
VHAWICOlsonD Line
VHAWICOlsonD Line To / From Rm 024-29
VHAWICOlsonD Line To Rm
VHAWICOlsonD Line
VHAWICOlsonD Text Box To Rm 012-61
VHAWICOlsonD Text Box To Rm 024-29
VHAWICOlsonD
To Rm 102-3
SPS DIRTY
ELEVATOR
055-34
SPS
CLEAN
ELEVATOR
066-34
EQUIP.
INVENTORY
MANAGEMENT
056-34
ELECT. RM
054-34
CLEAN
RECEIVING
DOCK
062-34
GAS
STORAGE
(EMPTY)
CORRIDOR
053-34
RECEIVING
058-34
057-34
BREAKDOWN
064-34
BOX
STORAGE
STAIR
068-34
FULL CYL.
STORAGE
060-34
STAIRS
051-34
VESTIBULE
052-34
ELEVATOR
MECHANICAL
STORAGE
RM
069-34
CLEAN
STORAGE
065-34
TLT
059-34
MED/SURGE
CACHE
WAREHOUSE
EMS & NX
RX
STORAGE
CACHE
WAREHOUSE
EXPENDABLE
SUPPLY
NX
STAFF
021-34020-34019-34018-34017-34016-34
015-34
014-34
024-34
013-34
009-34
008-34
2109 SF
013-34
1123 SF
582 SF
002A-34
1355 SF
023-34
527 SF
BREAKROOM
HALL
484 SF
868 SF
250 SF
811 SF
100 SF
347 SF
56 SF
51 SF
AutoCAD SHX Text
0-STAIR-W
AutoCAD SHX Text 001B
AutoCAD SHX Text 001A
AutoCAD SHX Text
AutoCAD SHX Text
MECH RM
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
0-ELEV-W
AutoCAD SHX Text
ELEVATOR
VHAWICOlsonD Rectangle Rm SP001B-34(Panel #8) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line To bldg 1
VHAWICOlsonD Line To bldg 4
VHAWICOlsonD Text Box To Rm 009C-4
VHAWICOlsonD Text Box To Rm 015-2
Rm 113A-60 (Panel #10) 24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD Line To Bldg 4
VHAWICOlsonD Line
VHAWICOlsonD Line To BLDG 16
VHAWICOlsonD Text Box To Rm 108-16
VHAWICOlsonD
To Rm 009C-4
24 terminations with LC type connectors on 2 existing 12 Strand OM1 62.5 fibers
VHAWICOlsonD Line To 050-26
VHAWICOlsonD Line
VHAWICOlsonD Rectangle Fiber goes from ground floor to 1st floor closet here
VHAWICOlsonD Line
VHAWICOlsonD Line To Rm 105-61
VHAWICOlsonD Text Box To 050-26
VHAWICOlsonD
To Rm 105-61
Rm 105-61 (Panel #1) 12 terminations with LC type connectors on 1 12 Strand OM1 62.5 fibers.
VHAWICOlsonD Line
VHAWICOlsonD Line To Rm 013-61
VHAWICOlsonD Line
VHAWICOlsonD Line
VHAWICOlsonD
To Rm 012-61
File details come from the government source that posted it. Updated .