B26 Floor Plans.pdf
PDF 857 KB Posted
- Solicitation number
- 36C25526Q0243-1
About this file
This document is an architectural floor plan for a Veterans Health Administration facility renovation project. The plan depicts the overall ground floor and first floor layouts for the construction and infill of Building 26 to renovate specialty care clinics at a VA Health Care System location.
The project encompasses multiple clinical departments and support spaces across the two floors shown. Ground floor spaces include dining facilities, kitchen, retail store, various clinical laboratories (DTR-1 through DTR-8), dental services, radiology, and administrative offices. First floor spaces contain neurology, gastroenterology/rheumatology, pulmonary/sleep medicine, renal dialysis, and various examination and procedure rooms, along with supporting utility, storage, and staff facilities. The design is prepared at 1/8" scale and dated December 20, 2022. The architectural firm is Spur Design, LLC (Oklahoma City), with structural/civil engineering by H2B, Inc. (Houston), mechanical/electrical/plumbing by Spur Design (Kansas City), fire protection by Poole Fire Protection (Kansas), industrial hygiene by Riverfront Health & Safety (St. Louis), healthcare planning by Innova Group (Tucson), and physical security by Force Protect (Panama City). The document is marked as preliminary and incomplete, not for construction or implementation purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25526Q0243 0003.pdf | ||
| 36C25526Q0243 PA System RFI Responses.xlsx | XLSX spreadsheet | |
| Fiber Map Combined 08.28.pdf | ||
| 26-603A Floor Plans Bldg Info 08.28.pdf | ||
| 36C25526Q0243 0002.pdf | ||
| Life Safety Drawing Campus Wide 08.28.pdf | ||
| RJDVAMC Floor Plans 2022.pdf | ||
| B60A Floor Plans.pdf | ||
| 36C25526Q0243 0001.pdf | ||
| 26-603A Floor Plans.pdf | ||
| 36C25526Q0243-1.pdf | ||
| Wage Determination by reference.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
B C D E F G
BLDG 61
BLDG 29BLDG 62
B
B62
B
B
B
B
B
B
B
B29
B3
BLDG 26
H J K L M
WORKSTATIONS
001A
WORKSTATIONS
001A
GUEST
SERVICES
HOLDING
CELL
001B
HOLDING
CELL
001B
HOLDING
CELL
001C
HOLDING
CELL
001C
STAIR
FREEZER
025D
FOOD STG
025A
COOLER
025C
FOOD STG
025B
DISH WASH KITCHEN
CORRIDOR
C1
RETAIL
STORAGE
024A
RETAIL
STORE
DINING AREA
SERVING LINE SAFE
026B
VCS CHIEF
OFFICE
026A
VCS OFFICE
DINING AREA
VENDOR
022A
CORRIDOR
C2
VESTIBULE
032A
AE301
12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"
'-4
8'
-4
'-6
7'
-9
7' -1
1/
2" 7'
-9
/2
7' -9
/2
7'
-1
1/ 2"
7' -9
'-4
8' -6
'-4
LAB
DTR-1
DTR-2
DTR-3
DTR-4
DTR-5
DTR-6
DTR-7
DTR-8
CHIEF
035B
WORKSTATIONS
RECEPTION
035A
COPY /
SUPPLY
035F
LOCKER
035C
DRESSING
035E LOUNGE
035D
IT ROOM
HAC
DENTAL
MECH
STORAGE
ELEC
CLEAN
SUPPLY
STERILE
EQUIPMENT
MOBILE
EQUIPMENT
X-RAY
WAITING
ENTRY
CHECK-IN
KIOSK
034A
WC ALC.
034B
STF TLT
PAT TLT
MEDICATION
TRAY
STORAGE
SOILED
UTILITY
CAD/CAM
CART
A008
EQUIP
A007
LIFT
A006
EQUIP
A005
WC
A004
EQUIP
A003
EQUIP
A002
CRASH CART
A001
CORRIDOR
C3
ELECTRICAL
AE301
A
SECURITY
157'-2"
AE121
AE111
3'
-2
AE121
P U
M P
R O
O M
FEC FEC
FEC
FEC
FEC FEC
KEY PLAN
BLDG 26
BLDG 3 BLDG 1
BLDG 2BLDG 19
BLDG 61
BLDG 62
BLDG 29
N
PHASE FOUR
SERVICE YARD
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.
REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN
THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.
8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.
GENERAL PLAN NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :5
A
M
AE101
OVERALL REFERENCE PLAN - GROUND
FLOOR
ECO
40 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
OVERALL GROUND FLOOR PLAN1
NO. REVISION DESCRIPTION DATE
UPUP
UP
B C D E F G
BLDG 61
BLDG 29BLDG 62
B
B62
B
B
B
B
B
B
B
B29
B3
BLDG 26
H J K L M
AE301
M E
C H
A N
IC
A
L C
H A
S E
SHARED
WAITING
100A
NEURO
NEURO
GI / RHEUM
GI / RHEUM
GI EXAM
GI EXAM
LOUNGE /
LOCKER
CLEAN
UTILITY
PAT TLT
NEURO
TEAM SPACE 1
GI EXAM
GI / RHEUM
CORRIDOR
CORRIDOR
RECEPTION
100B
CORRIDOR
PROC TLT
123B
MED EQUIP
STORAGE
PROCEDURE
ROOM
123A
MEDICATION
PFT
126A
PFT TLT
126B
SOILED
UTILITY
HAC
RENAL
HOME
OXYGEN
RENAL
RENAL
PULM / SLEEP
PULM / SLEEP
PULM / SLEEP
CPAP CONS.
FLEX EXAM
C-PAP STG
147PAT. TLT
VESTIBULE
122B
CPAP CONS.
141A
CPAP CONS.
143A
PULM / SLEEP
RENAL
CLEAN
UTILITY
RENAL
TEAM SPACE
122A
STF TLT
STG
141B STG
143B
CORR.
O2, FULL
129B
O2, EMPTY
129A
IT ROOM
ELEC
CRASH CART
A102
ALCOVE
A101
AE301
12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"
'-4
8'
-4
'-6
7'
-9
7' -1
1/
2" 7'
-9
/2
7' -9
/2
7'
-1
1/ 2"
7' -9
'-4
8' -6
'-4
STF TLT
M E
C H
A N
IC
A
L C
H A
S E
A AE121
157'-2"
AE111
RECEPTION
100C
FEC
FEC
FEC
FEC
FEC
KEY PLAN
BLDG 26
BLDG 3 BLDG 1
BLDG 2BLDG 19
BLDG 61
BLDG 62
BLDG 29
N
PHASE FOUR
SERVICE YARD
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.
REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN
THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.
8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.
GENERAL PLAN NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:5 :0
A
M
AE102
OVERALL REFERENCE PLAN - FIRST
FLOOR
ECO
41 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
OVERALL LEVEL FIRST FLOOR1
NO. REVISION DESCRIPTION DATE
VHAWICBerryC Rectangle
File details come from the government source that posted it. Updated .