B26 Floor Plans.pdf

PDF 857 KB Posted

Attached to
N059--PUBLIC ADDRESS SYSTEM STATION (VA-26-00046693)
Solicitation number
36C25526Q0243-1
Issued by

About this file

This document is an architectural floor plan for a Veterans Health Administration facility renovation project. The plan depicts the overall ground floor and first floor layouts for the construction and infill of Building 26 to renovate specialty care clinics at a VA Health Care System location.

The project encompasses multiple clinical departments and support spaces across the two floors shown. Ground floor spaces include dining facilities, kitchen, retail store, various clinical laboratories (DTR-1 through DTR-8), dental services, radiology, and administrative offices. First floor spaces contain neurology, gastroenterology/rheumatology, pulmonary/sleep medicine, renal dialysis, and various examination and procedure rooms, along with supporting utility, storage, and staff facilities. The design is prepared at 1/8" scale and dated December 20, 2022. The architectural firm is Spur Design, LLC (Oklahoma City), with structural/civil engineering by H2B, Inc. (Houston), mechanical/electrical/plumbing by Spur Design (Kansas City), fire protection by Poole Fire Protection (Kansas), industrial hygiene by Riverfront Health & Safety (St. Louis), healthcare planning by Innova Group (Tucson), and physical security by Force Protect (Panama City). The document is marked as preliminary and incomplete, not for construction or implementation purposes.

View the file

Other files

File Type Posted
36C25526Q0243 0003.pdf PDF
36C25526Q0243 PA System RFI Responses.xlsx XLSX spreadsheet
Fiber Map Combined 08.28.pdf PDF
26-603A Floor Plans Bldg Info 08.28.pdf PDF
36C25526Q0243 0002.pdf PDF
Life Safety Drawing Campus Wide 08.28.pdf PDF
RJDVAMC Floor Plans 2022.pdf PDF
B60A Floor Plans.pdf PDF
36C25526Q0243 0001.pdf PDF
26-603A Floor Plans.pdf PDF
36C25526Q0243-1.pdf PDF
Wage Determination by reference.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

B C D E F G

BLDG 61

BLDG 29BLDG 62

B

B62

B

B

B

B

B

B

B

B29

B3

BLDG 26

H J K L M

WORKSTATIONS

001A

WORKSTATIONS

001A

GUEST

SERVICES

HOLDING

CELL

001B

HOLDING

CELL

001B

HOLDING

CELL

001C

HOLDING

CELL

001C

STAIR

FREEZER

025D

FOOD STG

025A

COOLER

025C

FOOD STG

025B

DISH WASH KITCHEN

CORRIDOR

C1

RETAIL

STORAGE

024A

RETAIL

STORE

DINING AREA

SERVING LINE SAFE

026B

VCS CHIEF

OFFICE

026A

VCS OFFICE

DINING AREA

VENDOR

022A

CORRIDOR

C2

VESTIBULE

032A

AE301

12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"

'-4

8'

-4

'-6

7'

-9

7' -1

1/

2" 7'

-9

/2

7' -9

/2

7'

-1

1/ 2"

7' -9

'-4

8' -6

'-4

LAB

DTR-1

DTR-2

DTR-3

DTR-4

DTR-5

DTR-6

DTR-7

DTR-8

CHIEF

035B

WORKSTATIONS

RECEPTION

035A

COPY /

SUPPLY

035F

LOCKER

035C

DRESSING

035E LOUNGE

035D

IT ROOM

HAC

DENTAL

MECH

STORAGE

ELEC

CLEAN

SUPPLY

STERILE

EQUIPMENT

MOBILE

EQUIPMENT

X-RAY

WAITING

ENTRY

CHECK-IN

KIOSK

034A

WC ALC.

034B

STF TLT

PAT TLT

MEDICATION

TRAY

STORAGE

SOILED

UTILITY

CAD/CAM

CART

A008

EQUIP

A007

LIFT

A006

EQUIP

A005

WC

A004

EQUIP

A003

EQUIP

A002

CRASH CART

A001

CORRIDOR

C3

ELECTRICAL

AE301

A

SECURITY

157'-2"

AE121

AE111

3'

-2

AE121

P U

M P

R O

O M

FEC FEC

FEC

FEC

FEC FEC

KEY PLAN

BLDG 26

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

PHASE FOUR

SERVICE YARD

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.

REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.

3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN

THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.

8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.

GENERAL PLAN NOTES

PHASING AND PROJECT SCOPE LEGEND

AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT

SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/2

/2

:4 :5

A

M

AE101

OVERALL REFERENCE PLAN - GROUND

FLOOR

ECO

40 OF 190AJS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

OVERALL GROUND FLOOR PLAN1

NO. REVISION DESCRIPTION DATE

UPUP

UP

B C D E F G

BLDG 61

BLDG 29BLDG 62

B

B62

B

B

B

B

B

B

B

B29

B3

BLDG 26

H J K L M

AE301

M E

C H

A N

IC

A

L C

H A

S E

SHARED

WAITING

100A

NEURO

NEURO

GI / RHEUM

GI / RHEUM

GI EXAM

GI EXAM

LOUNGE /

LOCKER

CLEAN

UTILITY

PAT TLT

NEURO

TEAM SPACE 1

GI EXAM

GI / RHEUM

CORRIDOR

CORRIDOR

RECEPTION

100B

CORRIDOR

PROC TLT

123B

MED EQUIP

STORAGE

PROCEDURE

ROOM

123A

MEDICATION

PFT

126A

PFT TLT

126B

SOILED

UTILITY

HAC

RENAL

HOME

OXYGEN

RENAL

RENAL

PULM / SLEEP

PULM / SLEEP

PULM / SLEEP

CPAP CONS.

FLEX EXAM

C-PAP STG

147PAT. TLT

VESTIBULE

122B

CPAP CONS.

141A

CPAP CONS.

143A

PULM / SLEEP

RENAL

CLEAN

UTILITY

RENAL

TEAM SPACE

122A

STF TLT

STG

141B STG

143B

CORR.

O2, FULL

129B

O2, EMPTY

129A

IT ROOM

ELEC

CRASH CART

A102

ALCOVE

A101

AE301

12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"

'-4

8'

-4

'-6

7'

-9

7' -1

1/

2" 7'

-9

/2

7' -9

/2

7'

-1

1/ 2"

7' -9

'-4

8' -6

'-4

STF TLT

M E

C H

A N

IC

A

L C

H A

S E

A AE121

157'-2"

AE111

RECEPTION

100C

FEC

FEC

FEC

FEC

FEC

KEY PLAN

BLDG 26

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

PHASE FOUR

SERVICE YARD

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.

REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.

3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN

THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.

8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.

GENERAL PLAN NOTES

PHASING AND PROJECT SCOPE LEGEND

AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT

SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/2

/2

:5 :0

A

M

AE102

OVERALL REFERENCE PLAN - FIRST

FLOOR

ECO

41 OF 190AJS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

OVERALL LEVEL FIRST FLOOR1

NO. REVISION DESCRIPTION DATE

VHAWICBerryC Rectangle

File details come from the government source that posted it. Updated .