This document is a contract amendment modifying Solicitation 36C25524Q0408. The amendment provides details on the water filtration equipment and components required for the PCB Remediation project at the Wichita VAMC. It includes specifications for the MX-P2 Bag Filter Housing, MP2L-1 MYCELX Oil Removal Bag, BK-3 Housing, PP20LD1 Pleated Filter, MD20LD5 Filter, and MPW20LD1P PCB Filter. The amendment also answers vendor questions on the specific water filter brands, types, and sizes needed for this contract. The original solicitation is for a base year contract with four option years to furnish labor, materials, and waste disposal for PCB remediation at the Wichita VAMC, in compliance with TSCA and other federal requirements. The Department of Veterans Affairs, Veterans Integrated Service Network 15 is the contracting agency.

View the file

Other files

File Type Posted
36C25524Q0408 0006.docx DOCX document
36C25524Q0408 0004.docx DOCX document
36C25524Q0408 0003.docx DOCX document
36C25524Q0408 0002.docx DOCX document
36C25524Q0408 0001.docx DOCX document
36C25524Q0408.docx DOCX document
Wage Determination - 36C25524Q0408.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 657-24-2-1529-0468 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth

KS

66048 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth

KS

66048 To all Offerors/Bidders

36C25524Q0408 06-18-2024

X

X One(1) The purpose of this procurement is to answer a vendor's questions below.

Hogue, James Contracting Officer

CONTINUATION PAGE

Vendor Questions Answered:

Please let us know if we can get more information on water filters like the specific brand/type, or size of what appeared to be cartridge filters further down the filter sequence. Filter #1 also appeared to be a stainless-steel cartridge filter of non-specified filter media if you could kindly provide us these details.

MX-P2 Bag Filter Housing Inlet/Outlet: 2” NPT Construction Material: 316 SS Filter Capacity: 1 bag filter Height: 43” Diameter: 8”

MP2L-1 MYCELX Oil Removal Bag Infusion Coating: N/A Construction Material: Lined Polypropylene Felt Filter Material: MYCELX PermaKleen Diameter: 7” Length: 32”

BK-3 Housing Inlet/Outlet: 1-1/2” NPT (female) Construction Material: Opaque Polypropylene Bowl

PP20LD1 Pleated Filter (5-micron) Infusion Coating: N/A Construction Material: Synthetic Diameter: 4-1/2” Inside Diameter: 1:

Length: 20” Micron Rating: 5 nominal

MD20LD5 Filter for BK-3 Housing Infusion Coating: MYCELX Construction Material: Spunbound Polypropylene Diameter: 4-1/2” Inside Diameter: 1” Length: 20” Micron Rating: 5 nominal

MPW20LD1P PCB Filter Infusion Coating: MYCELX for PCBs Construction Material: Spunbound Polypropylene Diameter: 4-1/2” Inside Diameter: 1” Length: 20” Micron Rating: 1 nominal