This document includes a topographic survey and related federal contract opportunity for construction services. The topographic survey provides detailed mapping of an area including control points, elevations, landmarks, and utility infrastructure to support development of a new Primary Care and Women's Health building at the Veterans Affairs Medical Center in Marion, Illinois. The related federal contract opportunity posted on SAM.gov seeks construction services for Project 657-503 to build the Primary Care and Women's Health building in accordance with the specifications provided in the topographic survey. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 15. The survey and solicitation include details to inform prospective offerors on the requirements for the federal construction project.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Control Point Table

Point #

Northing

386623.694

386181.806

385428.617

386250.045

386791.909

386102.614

385453.445

Easting

804154.764

804074.629

803745.750

804286.180

804213.273

803782.950

803686.486

Elevation

464.91

465.80

470.99

465.22

461.48

468.05

470.16

Description

Benchmark

Benchmark

Benchmark

1/2" Rebar Red Cap

1/2" Rebar Red Cap

1/2" Rebar Red Cap

1/2" Rebar Red Cap

CULVERT

DITCH FLOWLINE

FIRE HYDRANT

SIGN

LIGHT POLE

LEGEND

WATER VALVE

SANITARY SEWER

SANITARY MANHOLE

FENCE

PLAT OF

TOPOGRAPHIC SURVEY

VETERANS AFFAIRS MEDICAL CENTER

MARION, ILLINOIS

SURVEYOR'S CERTIFICATION

I, BRIAN P. PRICE, ILLINOIS PROFESSIONAL LAND SURVEYOR No. 035-003816, DO

HEREBY CERTIFY THAT AT THE REQUEST OF GUIDON, I HAVE CAUSED A TOPOGRAPHIC

SURVEY TO BE MADE OF THE TRACT OF LAND SHOWN HEREON.

THIS TOPOGRAPHIC PLAT IS A TRUE AND CORRECT

REPRESENTATION OF SAID SURVEY TO THE BEST OF MY

KNOWLEDGE AND BELIEF.

IN WITNESS THEREOF, I HAVE HEREUNTO SET MY

HAND AND AFFIXED MY SEAL AT MARION, ILLINOIS

THIS 10TH DAY OF SEPTEMBER, 2020.

BRIAN P. PRICE, PLS

No. 035-003816

THIS PROFESSIONAL SERVICE CONFORMS TO THE CURRENT

ILLINOIS MINIMUM STANDARDS FOR TOPOGRAPHIC SURVEYS.

THIS TOPOGRAPHIC SURVEY IS SIGNED AND SEALED AS REQUIRED BY ADMINISTRATIVE

CODE, SECTION 1270.56, MINIMUM STANDARDS OF PRACTICE. THIS DRAWING IS

CALLED A "PLAT" TO COINCIDE WITH 1270.56(f)(4).

SURVEYOR'S NOTES:

1. FIELD WORK WAS COMPLETED ON 06/25/2020.

2. HORIZONTAL DATUM IS BASED ON NAD 83 (2011).

3. VERTICAL DATUM IS BASED ON NAVD 88.

4. THIS IS A TOPOGRAPHIC SURVEY. THE PROPERTY LINES SHOWN

ON THIS SURVEY ARE FROM PLATS OF SURVEY BY PRICE FOR

ILLINOIS DEPARTMENT OF TRANSPORTATION, NEW HOPE

CHURCH AND THE CITY OF MARION, ILLINOIS.

ELECTRIC SWITCH BOX

INLET LID

UNDERGROUND CABLE MANHOLE

TREE (LESS THAN 6" DIA.)

CLEANOUT

INLET SQUARE GRATE

BENCHMARK

CONTROL POINT

TREE TRUNK

STUMP

TREELINE/DRIP EDGE

DOWN SPOUT

FINISH FLOOR ELEVATION

STORM SEWER

UNDERGROUND COMMUNICATION CABLE

GAS LINE

VICINITY MAP

MARION

#16

#10

#4

'X' CUT WEST SIDE

MAHGOLE RIM

#5

CHISELED SQUARE

ON HEADWALL

#6

CHISELED SQUARE

NORTHWEST SIDE

LIGHT BASE

#17

#18

MOD-5 MOD-6

MOD-1

NEW BUILDING

NO BUILDING

NUMBER ASSIGNED

AIR CONDITIONER UNIT

IE:454.23

IE:454.05

IE:454.39

IE:454.51

IE:455.29

15" HDPE

15" CMP

TC:460.66

IE:455.53

15" HDPE

TC:462.56

IE:457.97

TC:462.59

IE:457.57

TC:464.38

IE:458.96

TC:464.48

IE:458.65

TC:466.19

IE:460.05

TC:466.18

IE:459.92

15" HDPE 12" HDPE

IE:459.24

IE:458.46

8" CMP

IE:461.12

IE:461.14

IE:461.24

IE:461.78

8'X3' BOX CULVERT

18" RCP

IE:467.12

IE:466.49 IE:464.87

IE:465.73

IE:466.61

IE:467.07

IE:468.38

IE:468.54

9"CMP

15" RCP

6" HDPE

12" CMP

TC:467.33

IE:453.85

TC:466.39

IE:458.68

TC:467.99

IE:464.73

TC:467.07

IE:455.44

TC:467.69

IE:460.04

12" RCP

15" RCP

12" PVC

RIGHT OF WAY

PROPERTY LINE

PR

O

PE

R

TY

L

IN

E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

VF101

Sheet Name

A

F i l e

P a t h

P

M

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

TOPOGRAPHIC SURVEY

2401 W. MAIN STREET, MARION, IL

657-503

TBD

09/10/2020 WCB BPPRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO: 20.1006.00

65% DESIGN DEVELOPMENT

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

TOPOGRAPHIC SURVEY