This document outlines requirements for a leased modular building at the Jefferson Barracks campus of the St. Louis VA Medical Center. The VA seeks to lease a 9,150 square foot modular trailer unit for a base year plus four option years to house personnel and operations during a major renovation project. The unit must match the layout in the attached exhibit and comply with ADA, IBC, NFPA, NEC, and local building codes. It will be installed on a prepared site behind Building 25 on campus that has underground utilities connected or nearby. The solicitation was issued by the VA St. Louis VAMC on behalf of Veterans Health Administration VISN 15.

36C25520R0066 PLUMBING FIXTURES AND HARD WOOD CABINETS.pdf

View the file

Other files

File Type Posted
36C25520R0066-0004000.docx DOCX document
36C25520R0066-0003002.pdf PDF
36C25520R0066-0003000.docx DOCX document
36C25520R0066-0003001.pdf PDF
36C25520R0066-0002000.docx DOCX document
36C25520R0066-0001003.pdf PDF
36C25520R0066-0001000.docx DOCX document
36C25520R0066-0001001.pdf PDF
36C25520R0066-0001002.pdf PDF
36C25520R0066-020.pdf PDF
36C25520R0066-016.docx DOCX document
36C25520R0066-017.docx DOCX document
36C25520R0066-015.docx DOCX document
36C25520R0066-018.pdf PDF
36C25520R0066-021.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 22 40 00

PLUMBING FIXTURES AND HARD WOOD CABINETS

PART 1 - GENERAL

1.1 DESCRIPTION

Plumbing fixtures, associated trim and fittings necessary to make a complete installation from wall or floor connections to rough piping, and certain accessories. Install plumbing fixtures in stock manufactured hard wood base cabinets. Install matching hard wood wall cabinets above base cabinets.

PART 2 - PRODUCTS

2.1 STAINLESS STEEL

A. Corrosion-resistant Steel (CRS):

1. Plate, Sheet and Strip: CRS flat products shall conform to chemical composition requirements of any 300 series steel specified in ASTM

A276.

2. Finish: Exposed surfaces shall have standard polish (ground and polished) equal to NAAMM finish Number 4.

B. Die-cast zinc alloy products are prohibited.

2.2 SINKS

A. NEW STAINLESS STEEL SINGLE COMPARTMENT SINK MOUNTED IN PLASTIC

LAMINATE COUNTERTOP SET ON 48” WIDE BY 24” DEEP BASE CABINET.

SINK TO BE SELF RIMMING, BACK FAUCET LEDGE, APPROXIMATELY 21” BY

22”, 18ga CRS WITH A WRIST CONTROL FAUCET. PROVIDE THE FOLLOWING:

1. FAUCET: SOLID CAST BRASS CONSTRUCTION WITH WASHERLESS CERAMIC

MIXING CARTRIDGE TYPE AND CENTRALLY EXPOSED RIGID GOOSENECK

SPOUT WITH OUTLET 4 to 5 INCHES) ABOVE RIM. PROVIDE LAMINAR

FLOW CONTROL DEVICE. 4-INCH WRIST BLADE TYPE, HANDLES ON

FAUCET SHALL BE CAST FORMED OR DROP FORGED COPPER ALLOY.

EXPOSED METAL PARTS, INCLUDING EXPOSED PART UNDER VALVE

HANDLE WHEN IN OPEN POSITION, SHALL BE CHROME PLATED WITH A

SMOOTH BRIGHT FINISH.

2. DRAIN: CAST OR WROUGHT BRASS WITH FLAT GRID STRAINER, CHROME

PLATED.

2.3 PLYWOOD, HARDWOOD FACE VENEER MANUFACTURED BASE AND WALL CABINETS

A. HPVA HP-1, Premium Grade plain sliced Red Oak, Golden Oak Finish.

B. Sink base cabinets to be 24”deep x 48”wide x 34”high with one

(1) pair of 24” (nominal) doors.

C. Wall cabinets to be 12”deep x 48”wide x 30”high with two (2) moveable interior shelves and one (1) pair of 24” (nominal) doors.

2.4 PLASTIC LAMINATE COUNTERTOPS:

A. NEMA LD-3. Exposed countertop edge to be 1-1/2 inch thick.

B. Exposed decorative surfaces including countertops, and for items having plastic laminate finish. General purpose Type HGL.

C. Cabinet Interiors Including Shelving: Both of following options to comply with NEMA, LD3.1 as a minimum.

1. Plastic laminate clad plywood or particle board.

D. Backing sheet on bottom of plastic laminate covered wood tops. Backer Type BKL.

E. Post Forming Fabrication, Decorative Surface: Post forming Type HGP.

2.5 PLYWOOD, SOFTWOOD

Prod. Std. PS1, five ply construction from 1/2 inch to 1-

1/8 inch thickness, and seven ply for 1-1/4 inch thickness.

2.6 PARTICLEBOARD

CPA A208.1, Type 1, Grade 1-M-3.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Set casework in place; level, plumb and accurately scribe and secure to walls, and/or floors.

B. The installation shall be complete including all trim and hardware. Leave the casework clean and free from defects.

C. Extend plumbing water, waste and vent lines and connect to existing utilities as necessary to create a complete and fully functional installation.

3.2 FASTENINGS

A. Fastenings for securing casework to adjoining construction shall be as detailed on the approved shop drawings.

B. Provide reinforcement in walls and partitions as necessary for casework anchorage.

- - - E N D - - -