Correct Basement and Pharmacy Deficiencies (VA-19-00055107) 589A4-18-130
Solicitation number
36C25519R0081
Issued by

About this file

36C25519R0081 0002 AS102 - FLOOR PLANS_REV061319.pdf

View the file

Other files

File Type Posted
36C25519R0081-0003000.docx DOCX document
36C25519R0081-0002001.pdf PDF
36C25519R0081-0002000.docx DOCX document
36C25519R0081-0002003.pdf PDF
36C25519R0081-0001001.pdf PDF
36C25519R0081-0001002.pdf PDF
36C25519R0081-0001000.docx DOCX document
36C25519R0081-004.pdf PDF
36C25519R0081-001.docx DOCX document
36C25519R0081-003.pdf PDF
36C25519R0081-005.pdf PDF
36C25519R0081-002.pdf PDF
36C25519R0081-000.docx DOCX document
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT

LOCATION

SCOPE OF WORK LEGEND

SHADED AREA NOT IN SCOPE OF WORK

KLMNPQ

2' - 3" 11' - 5" 23' - 11" 5' - 6"

10' - 8" 10' - 1" 8' - 6" 6' - 1" 4' - 0"

TLT.

B011B

TLT.

B011H

ON-CALL

RM. 1

B011A

ON-CALL

RM. 2

B011C

ON-CALL

RM. 3

B011D

TLT.

B011E ON-CALL

RM. 4

B011F

ON-CALL

RM. 5

B011G

B011JHAS

B013

ON-CALL

ROOMS/LOUNGE

B011

OFFICE

B006

SHADED AREA NOT IN

SCOPE OF PROJECT

S H

A D

E D

A R

E A

N O

T I

N

S C

O P

E O

F P

R O

J E

C T

SHADED AREA NOT IN

SCOPE OF PROJECT

SHADED AREA NOT IN

SCOPE OF PROJECT

SHADED AREA NOT IN

SCOPE OF PROJECT

S H

A D

E D

A R

E A

N O

T

O P

E O

F P

R O

J E

C T

S H

A D

E D

A R

E A

N O

T

O P

E O

F P

R O

J E

C T

3' - 4"

8' - 5"

7' - 11"

90°

90°

EQ. EQ.

4' - 11"

3' - 1"

L3AR

L3AR

L3AR

L3AR

L3AR

L3A

LA3

L1N

L3N

L3N

L3N

L6A

L3N

L3N

L3A

L3A

L3A

L3N

L1N

L1N

L3A

L3A

L3A

L3A

L3A

L3A

L3N

L3A

L1N

L1N

L1N

L3A

L3A

L3A

L3N

L6A

L3AL1N

L1N

L1N

L1N

L1N

L1N

L1N L2N

L1N

L1N

L1N

L1N

L1N

L1N L1N

L1N

L2N

L1N

L1N

L1N

L1N L1N

L1N

L2N

VTS/TRVL

SUPRVISOR

B013A

LACTATION

B009

L3A

L6N

L1N

L1N

L1N L1N

L3A

L3A

L3A L3A

L3A

L3A

ASSOC.CHIEF

B006B

CHIEF

B006A

3' - 11" 10' - 5" 26' - 3"

L3A

B001F

B001D

B001A

CBA13

B019

B002A

B012

B017

B021

B045

B047 B046

B015

B046A

B049

B050

B007

B009A

CBB1

B014

B018

B016

B022

B023

B002

L1N L1N

L6N

L3A L3A2 2

OFFICE

B010A

OFFICE

B006C

OFFICE

B010

3' - 1"

10' - 1"

5' - 1"

5'

1"

L1N

L1N

L6AR

ACA

ACA

ACA

G

ACA

H

F235

F237

F219 F234

C2F15

F233

F238

F242

C2F16

L3A

L2T

L3A

SHADED AREA NOT IN

SCOPE OF PROJECT

SHADED AREA NOT IN

SCOPE OF PROJECT

SHADED AREA NOT IN

SCOPE OF PROJECT

CSCA

F236

C

LE

A N

D

IR

TY

CLEAN

DIRTY

D

IR

T Y

L E

A N

L3A

PROJECT

LOCATION

WALL MATERIALS

WALL TAG LEGEND

MATERIAL

WIDTH

STRUCTURAL METAL STUDS, 20 ga. OR

HEAVIER, (REF. STRUCT AND WET WALL DETAILS.)

LIGHT GAUGE METAL STUDS, 20 ga. TYP. (16ga. AT

TOILET ROOM PLUMBING WALLS) (REF. SPECS.)

DIMENSIONAL WOOD STUDS

CONCRETE MASONRY UNIT, STANDARD WEIGHTS

FOR EXTERIOR & INTERIOR, UNLESS NOTED

OTHERWISE (REF. STRUCT.)

COMPOSITE OR OTHER WALL TYPES, (REF. SECTIONS

& DETAILS)

WALL WIDTHS

7/8" HAT CHANNEL

1 5/8" HAT CHANNEL/ STUDS

2 1/2" SHAFT WALL FRAMING OR 2" H

STUD SHAFT WALL FRAMING

3 5/8" METAL STUD FRAMING

4" METAL STUD FRAMING

6" METAL STUD FRAMING

8" METAL STUD FRAMING

NOTES:

PROVIDE ACOUSTICAL SEALANT AROUND ENTIRE PERIMETER OF

ALL PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

PROVIDE SEALANT AROUND ENTIRE PERIMETER OF ALL

PENETRATIONS OF SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2" MTL.

DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACOUSTICAL (TO DECK)

XXXR

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATE WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AROUND ENTIRE PERIMETER OF ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS.

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

6" SHAFT WALL FRAMING

T - THERMAL

CODE (REF. SHT. GI-003)

8" MAS. CONC. BLOCK REF. SPECS.

0 -

1 -

2 -

3 -

4 -

6 -

8 -

7 -

9 -

PROVIDE 20GA. DOUBLE STUDS FULL HEIGHT AT ALL

INTERIOR DOOR JAMBS.

S -

L -

W -

B -

O -

LABEL ALL RATED WALLS PER CODE.

R - INDICATES WALL IS RATED FOR FIRE OCCUPANCY,

AND/OR SMOKE. SEE LIFE SAFETY PLAN FOR RATING

TYPE. REFER TO LEGEND ON LIFE SAFETY SHEET FOR

APPLICABLE UL ASSEMBLY REFERENCES.

CODE

A. REFERENCE THE LIFE SAFETY PLAN AND LEGEND FOR ANY WALL TYPES ENDING IN "R". NOTE THAT ALL

SUCH DESIGNATED WALLS ARE NOT FIRE RATED BUT MAY HAVE SMOKE PARTITION ASSEMBLY

REQUIREMENTS.

B. ALL EXISTING RATED OR SMOKE PARTITION WALLS THAT ARE TO REMAIN NEED TO BE PATCHED AND SEALED AS

REQUIRED TO MAINTAIN RATING OR SMOKE PARTITION REQUIREMENTS.

GENERAL FLOOR PLAN NOTES

MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE

ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS.

PRODUCTS OF OTHER MANUFACTURER'S EQUIVALENT TO COLORS,

FINISHES, TEXTURES AND PATTERNS OF MANUFACTURERS LISTED

THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS WILL BE

ACCEPTABLE UPON APPROVAL IN WRITING BY CONTRACTING

OFFICER FOR FINISH REQUIREMENTS.

- THIS NOTE APPLIES TO ALL SUCH INSTANCES IN THE DRAWINGS

AND SPECIFICATIONS FOR THIS PROJECT.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

SEAL:

623 MASSACHUSETTS STREET

SUITE #200

LAWRENCE, KANSAS 66044

785.842.6464

AS102

FLOOR PLANS - PARTIAL BASEMENT &

SECOND FLOOR DIMENSIONS

CORRECT BASEMENT AND

PHARMACY DEFICIENCIES

Columbia, MO

05/13/2019

589A4-18-130

100% CONSTRUCTION DOCUMENTS

1" = 100'-0"

KEY PLAN - BASEMENT4' 8' 16'

1/8" = 1'-0"

0'

N N

4' 8' 16'

1/8" = 1'-0"

0'

N

N

1/8" = 1'-0"

FLOOR PLAN - PARTIAL BASEMENT DIMENSIONS

1/4" = 1'-0"

FLOOR PLAN - PARTIAL SECOND FLOOR DIMENSIONS

1" = 100'-0"

KEY PLAN - SECOND FLOOR

PLAN NOTES - FLOOR PLAN

1 CONTRACTOR TO VERIFY EXISTING WALL ASSEMBLY MEETS REQUIRED 1HR RATING. WALL MUST EXTEND TO BOTTOM OF DECK AND

BE FIRE CAULKED AT TOP AND BOTTOM. LABEL WALL.

2 DEMO, INFILL OF DOOR AND PATCHING/PAINTING OF WALL TO BE DONE NIGHTS OR WEEKENDS

3 NEW EXPANSION JOINT COVERS AT FLOOR, WALLS AND CEILING, REF. SPECS.

4 INSTALL FIRE EXTINGUISHER CABINET

1 Ammendment 2 2019-06-13

Sheets
AS102 - FLOOR PLANS - PARTIAL BASEMENT & SECOND FLOOR DIMENSIONS