Drawings_657-17-184JB_2of5_-_13_pages.pdf
PDF 8 MB Posted
- Attached to
- Replace Mechanical Systems in B2 657-17-184JB Federal contract opportunity
- Solicitation number
- 36C25519R0007
About this file
36C25519R0007 Drawings 657-17-184JB 2of5 - 13 pages.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25519R0007-0001001.pdf | ||
| 36C25519R0007-0001000.docx | DOCX document | |
| Drawings_657-17-184JB_4of5_-_11_pages.pdf | ||
| Drawings_657-17-184JB_3of5_-_13_pages.pdf | ||
| 36C25519R0007.docx | DOCX document | |
| Drawings_657-17-184JB_1of5_-_1_page.pdf | ||
| Drawings_657-17-184JB_5of5_-_10_pages.pdf | ||
| 2018-10-17_Bid_Specifications.pdf | ||
| 36C25519R0007-002.docx | DOCX document | |
| 36C25519R0007-001.docx | DOCX document | |
| 36C25519R0007-000.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
f'
C i' i"
D i'
I:
r---, 10 r ' '
PRINTS OF THIS DRAW,llG SHALL 1':0T BE USED FOR "1N PURPOSE ','11-\ATSOEVER \'lmiOUT THE SEAL AUD S!GllATURE Of THE
PROFESSIONAL EJ/Gl:IEER.
,-L I
1r--,---7 1
I I I I I I
I I I
I I
I I I I
, I
I I I I I I I I I I I I
I I I I
CONSULTANTS:
D:lSTlNG A!.'I COOLED CH:tl.ER
I I �l
H001 r -----, !0 i
1L __ �I L ------�
I "- - --- --
I I
I l ____ _J
0����1��-L BASEMENT PLAN ABATEMENT
/Jll.LER-REWCK UC
PROFESSIO/IAL EllGmEER
7 8
;-:11��';!��';,;;.,1;!:,C �-)1 A Se,vi;:a Disa/1� Ve:erari O�ned �. ./2 Sma., &u.ne.ss :...,•
IOIOKJNGS HIGHWAY SOUTH
CHERRY HILL, NE\'/ JERSEY 080.J-I
PHONE: (856)-1294000
FAX:(856).129-5002
I.IR PROJECT IJ0:0509-0001
fr ___ _j_ll ,---,7
11 I I
I I
I
11 I I 11 I 11
I I
11 11
11 I 11
11 I I r-----, l ' I I ! 0 l j L ___ : /
!0 !
GENERAL COMMENTS:
,;:--, j -�--=---- L
Dnrt.TIQTill
HAZARDOUS MATERIAL REMEDIATION
- BASEMENT PLAN
I/ORTH
NORTH
ACnJAcE9
BID DOCUMENTS
���LACE MECHANICAL l���-184JB I
SYSTEMS IN BUILDING 2
IBuif rg
N<rrl>o' I VAMC, St. LOUIS MISSOURI BLDG. 2 l lux:sfun ST LOUIS, MISSOURI I Orawi1gNi.rnbet r·5/8/18 11°'"':E IQ HA-01
Veterans Health
Administration
Department of Veterans Affairs
A
C
D
ENV. REMEDIATION NOTES:
1. PLEASE REFERENCE WRITTEN PROJECT SPECIFIC TECHNICAL
SPECIFICATIONS FOR REQUIREMENTS ASSOCIATED WITH ALL
ASBESTOS AND/OR LEAD PAINT ABATEMENT RELATED WORK
WITHIN TS 02.82.13 AND TS 02.83.33.13.
2. COORDINATE LOCATION OF DUMPSTER WITH VA AND REPAIR
ANY DAMAGE TO SITE.
3. COORDINATE ALL REMOVALS WITH SUGGESTED PHASING PLAN
1. ALL LBP RELATED WORK TO BE PERFORMED W/IN A FULLY CONTAINED
NEGATIVE PRESSURE ENCLOSURE (NPE) EQUIPPED WITH: 1 X LAYER OF
6-MIL POLY SHEETING ON UNAFFECTED WALLS; 2 X LAYERS OF 6 MIL
POLY ON FLOORS OVERLAIN BY 1 X LAYER OF 40 MIL RUBBER
MEMBRANE; 2 X LAYERS OF 6-MIL POLY OVER ALL CRITICAL BARRIERS; 3
X STAGE WET PERSONNEL DECONTAMINATION STATION; 2 STAGE
WASTE LOADOUT STATION; HEPA FILTERED NEGATIVE AIR MACHINES
CAPABLE OF PRODCING A MINIMUM OF -0.02 IN WG PRESSURE
DIFFERENTIAL AND 4 AIR CHANGES PER HR; ELECTRONIC RECORDING
2.
3.
4.
MANOMETER; 18" X 18" VIEWING WINDOWS; ADHESIVE STRIP PADS
OUTSIDE ENTRY TO EACH NPE. CONTRACTOR WILL BE GIVEN CONTROL
OF ONE FLOOR PER PHASE WITH ONE NPE PER FLOOR.
LOOSE/FLAKING LEAD BASED PAINT PREVIOUSLY STABILIZED ON GFL;
SCOPE LIMITED TO PENETRATION SCOPE ONLY.
ALL LOOSE/FLAKING LBP TO BE STABILIZED USING WET HANDSCRAPING
MEANS TO REMOVE ALL PAINT CAPABLE OF BEING DISLODGED OR
DISTURBED USING HAND PRESSURE ALONE, AS VERIFIED BY VPIH, THEN
ENCAPSULATED WITH TWO LAYERS OF WHITE TINTED LEAD BLOCKING
PRIMER APPROVED BY VPIH. 29 CFR 1926.62 APPLIES TO ALL WORK.
EACH FCU WILL REQUIRE UP TO 5 WALL PENETRATIONS THROUGH LBP
SURFACES; CONTRACTOR TO MAKE PENETRATIONS AS DIRECTED BY
GENERAL CONTRACTOR TO ACCOMODATE INSTALLATION OF NEW FCUs
AS SHOWN ON CONTRACT DRAWINGS, WITH SPECIFIC LOCATIONS TO BE
FIELD DETERMINED AT EACH FCU (APPROX. 65 UNITS TOTAL). ALL WALL
PENETRATION WORK TO BE DONE WITHIN NPE.
5. NEW COMPONENT INSTALLATION WILL REQUIRE PLACEMENT OF NEW
CEILING ANCHORS THROUGH LBP LAYERS THROUGHOUT BLDG 2;
CONTRACTOR TO INSTALL ANCHORS AS DIRECTED BY GENERAL
CONTRACTOR TO ACCOMODATE INSTALLATION OF UTILITY BRACKETS
FOR NEW HVAC COMPONENTS AS SHOWN ON CONTRACT DRAWINGS,
WITH SPECIFIC LOCATIONS TO BE FIELD DETERMINED. ALL ANCHOR
INSTALLS TO BE DONE WITHIN NPE (APPROX 1,500 LOCATIONS).
6. LBP STABILIZATION TO BE COMPLETED FOLLOWING REMOVAL OF ALL
SUSPENDED CEILING GRID SYSTEMS WITHIN NPE AS LEAD REGULATED
ACTIVITY BUT PRIOR TO FCU WALL PENETRATION AND CEILING ANCHOR
WORK; NPE TO BE CLEANED AND CLEARED (BY VPIH INSPECTION) THEN
SPOT LOCATIONS MARKED BY GC THEN SECOND ROUND OF CLEANING
BEFORE FINAL CLEARANCE SAMPLING. THIS PHASING IS REQUIRED.
7. CLEARANCE SAMPLING BY VPIH TO COMPLY WITH 30 MCG/M3 AIR AND
40 MCG/FT2 LEAD STANDARDS. RE-CLEANING DUE TO FAILED CLEARAN-
CE SAMPLING IS RESPONSIBILITY OF CONTRACTOR.
8. NEW COMPONENT INSTALLATION ON EAST EXTERIOR FACADE WILL
REQUIRE SPOT ABATEMENT OF ACM STUCCO BEHIND EFIS LAYER TO
ACCOMODATE WALL ANCHORS (APPROX. 24). ALL STUCCO REMOVAL TO
BE DONE USING GLOVEBAG TECHNIQUES TO REMOVE APPROX. 6"X6"
AREA FOR EACH ANCHOR POINT, WITH PRECISE LOCATIONS DETERMIN-
ED BY GC AS NEEDED. CONTRACTOR TO ESTABLISH REGULATED WORK
AREA IAW 29 CFR 1926.1101 AND STL COUNTY ORDINANCES. ELEVATED
WORK TO BE PERFORMED USING AERIAL LIFT WITH POLY DROP SHEET
BELOW TO ENSURE PROTECTION OF GROUND SURFACE BELOW. EFIS
LAYER TO BE REPAIRED BY GC AS NEEDED FOLLOWING ACM REMOVAL.
DWG 2 OF 47
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO
314-436-9492 JR
B
B
B
B
CR SR ER WLO
ABATEMENT LEGEND:
HEPA FILTERED NEGATIVE AIR MACHINE
WASTE LOAD OUT ROOM
DECON SHOWER ROOM
DECON CLEAN ROOM
DECON EQUIPMENT ROOM
B
SR
ER
WLO
CR
NEGATIVE PRESSURE ENCLOSURE BOUNDARY
jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line
B A !
C
I'
D i'
T I I
I I
I I
PRJ/lTS OF THIS ORAWJI(; SHALL NOT SE USED FOR MN PUKPOSE WHATSOEVER \'/111-10UT THE SEAL AUO SIG/IATURi: OF THE PROfESSIOUAL EllGlt/EER.
VAFORMO&-G2J1
T ', r, . A r T
-1 \ - �;·o::__ 8=�
I I I I
I I e-------1 � I I
�E I I >----I- ,_____ I I
I I
CONSULTANTS:
T T I I I I
I I I I
I I I I
I I
MECHAN CAL Fl ST FLOOR PLAN ABATEMENT 5CAl..£; 1/4" • 1·-0·
IJLLER-REtJICK UC PROFESSIOUAl. EUGCIEER r T T I I I I
I I I I
I I I I
I I
PW/
NORTH �:;;;:':ffi
BID DOCUMENTS
=M::--.E�
H- A -NI-C-AL_ _ _ _ _ _ _ ���LACE MECHANICAL 1��7,-184JB I
SYSTEMS IN BUILDING 2
I Bui/r,gNiiiiiei
I VAMC, St. LOUIS MISSOURI BLDG. 2
�oi-:�:!i��ii.'<:��A�%�08i),H r
:PiijitDi'ec:tlr Locsti:Jo ST LOUIS, MISSOUR� I DmmgNt.mbo, PHONE: (856)-ln-«:m . . FAX:(856}-ln.5002
� ... PROJECTIIO.o=xxJ, I°"" ll�E I i ___:'.:_J � e:i:,�:���:,.
A
C
D
ENV. REMEDIATION NOTES:
1. ALL LBP RELATED WORK TO BE PERFORMED W/IN A FULLY CONTAINED
NEGATIVE PRESSURE ENCLOSURE (NPE) EQUIPPED WITH: 1 X LAYER OF
6-MIL POLY SHEETING ON UNAFFECTED WALLS; 2 X LAYERS OF 6 MIL
POLY ON FLOORS OVERLAIN BY 1 X LAYER OF 40 MIL RUBBER
MEMBRANE; 2 X LAYERS OF 6-MIL POLY OVER ALL CRITICAL BARRIERS; 3
X STAGE WET PERSONNEL DECONTAMINATION STATION; 2 STAGE
WASTE LOADOUT STATION; HEPA FILTERED NEGATIVE AIR MACHINES
CAPABLE OF PRODCING A MINIMUM OF -0.02 IN WG PRESSURE
DIFFERENTIAL AND 4 AIR CHANGES PER HR; ELECTRONIC RECORDING
2.
3.
4.
MANOMETER; 18" X 18" VIEWING WINDOWS; ADHESIVE STRIP PADS
OUTSIDE ENTRY TO EACH NPE. CONTRACTOR WILL BE GIVEN CONTROL
OF ONE FLOOR PER PHASE WITH ONE NPE PER FLOOR.
LOOSE/FLAKING LEAD BASED PAINT PRESENT ON ALL PAINTED PLASTER
& CONCRETE SURFACES THROUGHOUT BUILDING 2 ABOVE DROP
CEILINGS ON CEILING DECKS & ORIGINAL WALLS (1FL TOTALS APPROX.
6,000 SQFT)
ALL LOOSE/FLAKING LBP TO BE STABILIZED USING WET HANDSCRAPING
MEANS TO REMOVE ALL PAINT CAPABLE OF BEING DISLODGED OR
DISTURBED USING HAND PRESSURE ALONE, AS VERIFIED BY VPIH, THEN
ENCAPSULATED WITH TWO LAYERS OF WHITE TINTED LEAD BLOCKING
PRIMER APPROVED BY VPIH. 29 CFR 1926.62 APPLIES TO ALL WORK.
EACH FCU WILL REQUIRE UP TO 5 WALL PENETRATIONS THROUGH LBP
SURFACES; CONTRACTOR TO MAKE PENETRATIONS AS DIRECTED BY
GENERAL CONTRACTOR TO ACCOMODATE INSTALLATION OF NEW FCUs
AS SHOWN ON CONTRACT DRAWINGS, WITH SPECIFIC LOCATIONS TO BE
FIELD DETERMINED AT EACH FCU (APPROX. 65 UNITS TOTAL). ALL WALL
PENETRATION WORK TO BE DONE WITHIN NPE.
5. NEW COMPONENT INSTALLATION WILL REQUIRE PLACEMENT OF NEW
CEILING ANCHORS THROUGH LBP LAYERS THROUGHOUT BLDG 2;
CONTRACTOR TO INSTALL ANCHORS AS DIRECTED BY GENERAL
CONTRACTOR TO ACCOMODATE INSTALLATION OF UTILITY BRACKETS
FOR NEW HVAC COMPONENTS AS SHOWN ON CONTRACT DRAWINGS,
WITH SPECIFIC LOCATIONS TO BE FIELD DETERMINED. ALL ANCHOR
INSTALLS TO BE DONE WITHIN NPE (APPROX 1,500 LOCATIONS).
6. LBP STABILIZATION TO BE COMPLETED FOLLOWING REMOVAL OF ALL
7.
SUSPENDED CEILING GRID SYSTEMS WITHIN NPE AS LEAD REGULATED
ACTIVITY BUT PRIOR TO FCU WALL PENETRATION AND CEILING ANCHOR
WORK; NPE TO BE CLEANED AND CLEARED (BY VPIH INSPECTION) THEN
SPOT LOCATIONS MARKED BY GC THEN SECOND ROUND OF CLEANING
BEFORE FINAL CLEARANCE SAMPLING. THIS PHASING IS REQUIRED.
CLEARANCE SAMPLING BY VPIH TO COMPLY WITH 30 MCG/M3 AIR AND
40 MCG/FT2 LEAD STANDARDS. RE-CLEANING DUE TO FAILED CLEARAN-
CE SAMPLING IS RESPONSIBILITY OF CONTRACTOR.
8. NEW COMPONENT INSTALLATION ON EAST EXTERIOR FACADE WILL
REQUIRE SPOT ABATEMENT OF ACM STUCCO BEHIND EFIS LAYER TO
ACCOMODATE WALL ANCHORS (APPROX. 24). ALL STUCCO REMOVAL TO
BE DONE USING GLOVEBAG TECHNIQUES TO REMOVE APPROX. 6"X6"
AREA FOR EACH ANCHOR POINT, WITH PRECISE LOCATIONS DETERMIN-
ED BY GC AS NEEDED. CONTRACTOR TO ESTABLISH REGULATED WORK
AREA IAW 29 CFR 1926.1101 AND STL COUNTY ORDINANCES. ELEVATED
WORK TO BE PERFORMED USING AERIAL LIFT WITH POLY DROP SHEET
BELOW TO ENSURE PROTECTION OF GROUND SURFACE BELOW. EFIS
LAYER TO BE REPAIRED BY GC AS NEEDED FOLLOWING ACM REMOVAL.
GENERAL COMMENTS:
1. PLEASE REFERENCE WRITTEN PROJECT SPECIFIC TECHNICAL
SPECIFICATIONS FOR REQUIREMENTS ASSOCIATED WITH ALL
ASBESTOS AND/OR LEAD PAINT ABATEMENT RELATED WORK
WITHIN TS 02.82.13 AND TS 02.83.33.13.
2. COORDINATE LOCATION OF DUMPSTER WITH VA AND REPAIR
ANY DAMAGE TO SITE.
3. COORDINATE ALL REMOVALS WITH SUGGESTED PHASING PLAN
Veterans Health
Administration
HAZARDOUS MATERIAL REMEDIATION -
1FL PLAN
DWG 3 OF 47
HA-02
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO
314-436-9492
JR5/8/18
B
B B
B
B B
B B B B
ABATEMENT LEGEND:
B
SR
ER
WLO
CR
WASTE LOAD OUT ROOM
DECON EQUIPMENT ROOM
DECON SHOWER ROOM
DECON CLEAN ROOM
HEPA FILTERED NEGATIVE AIR MACHINE
NEGATIVE PRESSURE ENCLOSURE BOUNDARY
WLO
ER
SR
CR
WLO DRY 2-STAGE DECON STATION
jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Callout
LEAVE STAIRWELL UNOBSTRUCTED FOR EMERGENCY EGRESS BY OCCUPANTS DURING ABATEMENT
jrhyn Callout
CENTRAL STAIRWELL TO BE USED AS PRIMARY EGRESS FOR OCCUPANTS DURING ABATEMENT
jrhyn Polygonal Line jrhyn Callout ASBESTOS REGULATED WORK AREA FOR STUCCO GLOVEBAG REMOVAL WORK; TO BE COVERED WITH DROP CLOTH & RESTRICTED WITH SIGNAGE/BOUNDARY TAPE DURING ACTIVE REMOVAL
C
D
J i j' J.
I, I
J, I
I
J
J i'
J I
0--
PRJtrTS OF THIS DRAWitlG SHALL NOT BE USED FOR IJN PURPOSE
WHATSOEVER WITHOUT THE SEAL AIIO SIGIIATURE OF THE
PROFESSIOUAL ENGINEER
OESCRl?TION
VA.FORM0&-6231
I
! :,;JC 3
CONSULTANTS:
f T
0 ��f�lf_�� SECOND FLOOR PLAN ABATEMENT
I.IILLER·REJJICl< UC PROFESSIONAL EllGINEER
T ll
T
PWl I/ORTl1 ACTIJ"'-ffi "°"'"w
BID DOCUMENTS
R;�LACE MECHANICAL ,��-184JB I Office of SYSTEMS IN BUILDING 2 IBui/"'Niii'bii IVAMC, St. LOUIS MISSOURI BLDG. 2 fOIOK/NGSHIGH:VAYSOiJTH
I a=� ="',Pro=;c i«1 =;;D;;='1lclor=========
U>al""' la.,, ;;1i£;�
RS£YDIK)J4
Dat8
STLOUJSl,[:;JMISSOURI
Q MD-1./R PROJECT 110. om-ooo1 � Department of
GE Jl � Veterans Affairs
C
D
1. ALL LBP RELATED WORK TO BE PERFORMED W/IN A FULLY CONTAINED
NEGATIVE PRESSURE ENCLOSURE (NPE) EQUIPPED WITH: 1 X LAYER OF
6-MIL POLY SHEETING ON UNAFFECTED WALLS; 2 X LAYERS OF 6 MIL
POLY ON FLOORS OVERLAIN BY 1 X LAYER OF 40 MIL RUBBER
MEMBRANE; 2 X LAYERS OF 6-MIL POLY OVER ALL CRITICAL BARRIERS; 3
X STAGE WET PERSONNEL DECONTAMINATION STATION; 2 STAGE
WASTE LOADOUT STATION; HEPA FILTERED NEGATIVE AIR MACHINES
CAPABLE OF PRODCING A MINIMUM OF -0.02 IN WG PRESSURE
DIFFERENTIAL AND 4 AIR CHANGES PER HR; ELECTRONIC RECORDING
2.
3.
4.
MANOMETER; 18" X 18" VIEWING WINDOWS; ADHESIVE STRIP PADS
OUTSIDE ENTRY TO EACH NPE. CONTRACTOR WILL BE GIVEN CONTROL
OF ONE FLOOR PER PHASE WITH ONE NPE PER FLOOR.
LOOSE/FLAKING LEAD BASED PAINT PRESENT ON ALL PAINTED PLASTER
& CONCRETE SURFACES THROUGHOUT BUILDING 2 ABOVE DROP
CEILINGS ON CEILING DECKS & ORIGINAL WALLS (2FL TOTALS APPROX.
6,000 SQFT)
ALL LOOSE/FLAKING LBP TO BE STABILIZED USING WET HANDSCRAPING
MEANS TO REMOVE ALL PAINT CAPABLE OF BEING DISLODGED OR
DISTURBED USING HAND PRESSURE ALONE, AS VERIFIED BY VPIH, THEN
ENCAPSULATED WITH TWO LAYERS OF WHITE TINTED LEAD BLOCKING
PRIMER APPROVED BY VPIH. 29 CFR 1926.62 APPLIES TO ALL WORK.
EACH FCU WILL REQUIRE UP TO 5 WALL PENETRATIONS THROUGH LBP
SURFACES; CONTRACTOR TO MAKE PENETRATIONS AS DIRECTED BY
GENERAL CONTRACTOR TO ACCOMODATE INSTALLATION OF NEW FCUs
AS SHOWN ON CONTRACT DRAWINGS, WITH SPECIFIC LOCATIONS TO BE
FIELD DETERMINED AT EACH FCU (APPROX. 65 UNITS TOTAL). ALL WALL
PENETRATION WORK TO BE DONE WITHIN NPE.
5. NEW COMPONENT INSTALLATION WILL REQUIRE PLACEMENT OF NEW
CEILING ANCHORS THROUGH LBP LAYERS THROUGHOUT BLDG 2;
CONTRACTOR TO INSTALL ANCHORS AS DIRECTED BY GENERAL
CONTRACTOR TO ACCOMODATE INSTALLATION OF UTILITY BRACKETS
FOR NEW HVAC COMPONENTS AS SHOWN ON CONTRACT DRAWINGS,
WITH SPECIFIC LOCATIONS TO BE FIELD DETERMINED. ALL ANCHOR
INSTALLS TO BE DONE WITHIN NPE (APPROX 1,500 LOCATIONS).
6. LBP STABILIZATION TO BE COMPLETED FOLLOWING REMOVAL OF ALL
7.
SUSPENDED CEILING GRID SYSTEMS WITHIN NPE AS LEAD REGULATED
ACTIVITY BUT PRIOR TO FCU WALL PENETRATION AND CEILING ANCHOR
WORK; NPE TO BE CLEANED AND CLEARED (BY VPIH INSPECTION) THEN
SPOT LOCATIONS MARKED BY GC THEN SECOND ROUND OF CLEANING
BEFORE FINAL CLEARANCE SAMPLING. THIS PHASING IS REQUIRED.
CLEARANCE SAMPLING BY VPIH TO COMPLY WITH 30 MCG/M3 AIR AND
40 MCG/FT2 LEAD STANDARDS. RE-CLEANING DUE TO FAILED CLEARAN-
CE SAMPLING IS RESPONSIBILITY OF CONTRACTOR.
8. NEW COMPONENT INSTALLATION ON EAST EXTERIOR FACADE WILL
REQUIRE SPOT ABATEMENT OF ACM STUCCO BEHIND EFIS LAYER TO
ACCOMODATE WALL ANCHORS (APPROX. 24). ALL STUCCO REMOVAL TO
BE DONE USING GLOVEBAG TECHNIQUES TO REMOVE APPROX. 6"X6"
AREA FOR EACH ANCHOR POINT, WITH PRECISE LOCATIONS DETERMIN-
ED BY GC AS NEEDED. CONTRACTOR TO ESTABLISH REGULATED WORK
AREA IAW 29 CFR 1926.1101 AND STL COUNTY ORDINANCES. ELEVATED
WORK TO BE PERFORMED USING AERIAL LIFT WITH POLY DROP SHEET
BELOW TO ENSURE PROTECTION OF GROUND SURFACE BELOW. EFIS
LAYER TO BE REPAIRED BY GC AS NEEDED FOLLOWING ACM REMOVAL.
ENV. REMEDIATION NOTES:
GENERAL COMMENTS:
1. PLEASE REFERENCE WRITTEN PROJECT SPECIFIC TECHNICAL
SPECIFICATIONS FOR REQUIREMENTS ASSOCIATED WITH ALL
ASBESTOS AND/OR LEAD PAINT ABATEMENT RELATED WORK
WITHIN TS 02.82.13 AND TS 02.83.33.13.
2. COORDINATE LOCATION OF DUMPSTER WITH VA AND REPAIR
ANY DAMAGE TO SITE.
3. COORDINATE ALL REMOVALS WITH SUGGESTED PHASING PLAN
Veterans Health
Administration
HAZARDOUS MATERIAL REMEDIATION -
2FL PLANI.IILLER·REJJICl< UC
PROFESSIONAL EllGINEER
DWG 4 OF 47
HA-03
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO
314-436-9492
5/8/18 JR
B
B B
B
B B
B B B B
ABATEMENT LEGEND:
B
SR
ER
WLO
CR
WASTE LOAD OUT ROOM
DECON EQUIPMENT ROOM
DECON SHOWER ROOM
DECON CLEAN ROOM
HEPA FILTERED NEGATIVE AIR MACHINE
NEGATIVE PRESSURE ENCLOSURE BOUNDARY
WLO
ER
SR
CR
jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Line jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Callout LEAVE ROOM FOR FOOT TRAFFIC IN CENTRAL STAIRWELL TO BE USED AS PRIMARY EGRESS FOR OCCUPANTS DURING ABATEMENT jrhyn
LEAVE STAIRWELL UNOBSTRUCTED FOR EMERGENCY EGRESS BY OCCUPANTS DURING ABATEMENT
C
D
B, I
I
B I
I I
I I
I I
0-----J
PRI/ITS Of THIS DRAWit/G SHAll NOT ae USED FOR AJN PURPOSE
\'IHATSOEVER \'/111-tOUT THE SEAL AUD SJGtlATURE OF THE
PROfESSl()UAl. EJlGUIEER
VAFORM05-6231
I j�0� �r.� -f---•-f--- -
,----------L t==I= =--
CONSULTANTS:
T T
0����1f�.L THIRD FLOOR PLAN ABATEMENT
IJII..LER-REtJIO<LLC
FROFESSIO'IAL EUGl!/EER
T T jl
PW/
ACTU>L ffi '"'""'w
BID DOCUMENTS
l��-184JB I
I Bui/..iNiinbei
I BLDG. 2
IOIOKINOSHIOH'.VAYSOIITH l:c,==Aj>p<lM,d==;c:=Pn>)eci=.,,cDrod<r==.======�,:c l loca==.ciliii=======:
E] llllbe1 �':,7fi::t���'.}g�RS£YD80J� ST LOUIS, MISSOURI
FAX; (856/429-5002 .
MRPROJECTUO,DSO><>OOI
lo.ca l[:;JC;J � Department or GE JL � VetecansAffalra
A
C 1. ALL LBP RELATED WORK TO BE PERFORMED W/IN A FULLY CONTAINED
NEGATIVE PRESSURE ENCLOSURE (NPE) EQUIPPED WITH: 1 X LAYER OF
6-MIL POLY SHEETING ON UNAFFECTED WALLS; 2 X LAYERS OF 6 MIL
POLY ON FLOORS OVERLAIN BY 1 X LAYER OF 40 MIL RUBBER
MEMBRANE; 2 X LAYERS OF 6-MIL POLY OVER ALL CRITICAL BARRIERS; 3
X STAGE WET PERSONNEL DECONTAMINATION STATION; 2 STAGE
WASTE LOADOUT STATION; HEPA FILTERED NEGATIVE AIR MACHINES
CAPABLE OF PRODCING A MINIMUM OF -0.02 IN WG PRESSURE
DIFFERENTIAL AND 4 AIR CHANGES PER HR; ELECTRONIC RECORDING
2.
3.
4.
MANOMETER; 18" X 18" VIEWING WINDOWS; ADHESIVE STRIP PADS
OUTSIDE ENTRY TO EACH NPE. CONTRACTOR WILL BE GIVEN CONTROL
OF ONE FLOOR PER PHASE WITH ONE NPE PER FLOOR.
LOOSE/FLAKING LEAD BASED PAINT PRESENT ON ALL PAINTED PLASTER
& CONCRETE SURFACES THROUGHOUT BUILDING 2 ABOVE DROP
CEILINGS ON CEILING DECKS & ORIGINAL WALLS (3FL TOTALS APPROX.
6,000 SQFT)
ALL LOOSE/FLAKING LBP TO BE STABILIZED USING WET HANDSCRAPING
MEANS TO REMOVE ALL PAINT CAPABLE OF BEING DISLODGED OR
DISTURBED USING HAND PRESSURE ALONE, AS VERIFIED BY VPIH, THEN
ENCAPSULATED WITH TWO LAYERS OF WHITE TINTED LEAD BLOCKING
PRIMER APPROVED BY VPIH. 29 CFR 1926.62 APPLIES TO ALL WORK.
EACH FCU WILL REQUIRE UP TO 5 WALL PENETRATIONS THROUGH LBP
SURFACES; CONTRACTOR TO MAKE PENETRATIONS AS DIRECTED BY
GENERAL CONTRACTOR TO ACCOMODATE INSTALLATION OF NEW FCUs
AS SHOWN ON CONTRACT DRAWINGS, WITH SPECIFIC LOCATIONS TO BE
FIELD DETERMINED AT EACH FCU (APPROX. 65 UNITS TOTAL). ALL WALL
PENETRATION WORK TO BE DONE WITHIN NPE.
5. NEW COMPONENT INSTALLATION WILL REQUIRE PLACEMENT OF NEW
CEILING ANCHORS THROUGH LBP LAYERS THROUGHOUT BLDG 2;
CONTRACTOR TO INSTALL ANCHORS AS DIRECTED BY GENERAL
CONTRACTOR TO ACCOMODATE INSTALLATION OF UTILITY BRACKETS
FOR NEW HVAC COMPONENTS AS SHOWN ON CONTRACT DRAWINGS,
WITH SPECIFIC LOCATIONS TO BE FIELD DETERMINED. ALL ANCHOR
INSTALLS TO BE DONE WITHIN NPE (APPROX 1,500 LOCATIONS).
6. LBP STABILIZATION TO BE COMPLETED FOLLOWING REMOVAL OF ALL
7.
SUSPENDED CEILING GRID SYSTEMS WITHIN NPE AS LEAD REGULATED
ACTIVITY BUT PRIOR TO FCU WALL PENETRATION AND CEILING ANCHOR
WORK; NPE TO BE CLEANED AND CLEARED (BY VPIH INSPECTION) THEN
SPOT LOCATIONS MARKED BY GC THEN SECOND ROUND OF CLEANING
BEFORE FINAL CLEARANCE SAMPLING. THIS PHASING IS REQUIRED.
CLEARANCE SAMPLING BY VPIH TO COMPLY WITH 30 MCG/M3 AIR AND
40 MCG/FT2 LEAD STANDARDS. RE-CLEANING DUE TO FAILED CLEARAN-
CE SAMPLING IS RESPONSIBILITY OF CONTRACTOR.
8. NEW COMPONENT INSTALLATION ON EAST EXTERIOR FACADE WILL
REQUIRE SPOT ABATEMENT OF ACM STUCCO BEHIND EFIS LAYER TO
ACCOMODATE WALL ANCHORS (APPROX. 24). ALL STUCCO REMOVAL TO
BE DONE USING GLOVEBAG TECHNIQUES TO REMOVE APPROX. 6"X6"
AREA FOR EACH ANCHOR POINT, WITH PRECISE LOCATIONS DETERMIN-
ED BY GC AS NEEDED. CONTRACTOR TO ESTABLISH REGULATED WORK
AREA IAW 29 CFR 1926.1101 AND STL COUNTY ORDINANCES. ELEVATED
WORK TO BE PERFORMED USING AERIAL LIFT WITH POLY DROP SHEET
BELOW TO ENSURE PROTECTION OF GROUND SURFACE BELOW. EFIS
LAYER TO BE REPAIRED BY GC AS NEEDED FOLLOWING ACM REMOVAL.
ENV. REMEDIATION NOTES:
GENERAL COMMENTS:
1. PLEASE REFERENCE WRITTEN PROJECT SPECIFIC TECHNICAL
SPECIFICATIONS FOR REQUIREMENTS ASSOCIATED WITH ALL
ASBESTOS AND/OR LEAD PAINT ABATEMENT RELATED WORK
WITHIN TS 02.82.13 AND TS 02.83.33.13.
2. COORDINATE LOCATION OF DUMPSTER WITH VA AND REPAIR
ANY DAMAGE TO SITE.
3. COORDINATE ALL REMOVALS WITH SUGGESTED PHASING PLAN
Veterans Health
Administration
HAZARDOUS MATERIAL REMEDIATION -
3FL PLAN
���LACE MECHANICAL
SYSTEMS IN BUILDING 2
VAMC, St. LOUIS MISSOURI
DWG 5 OF 47
HA-04
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO
314-436-9492
5/8/18 JR
B
B B
B
B B
B B B B
ABATEMENT LEGEND:
B
SR
ER
WLO
CR
WASTE LOAD OUT ROOM
DECON EQUIPMENT ROOM
DECON SHOWER ROOM
DECON CLEAN ROOM
HEPA FILTERED NEGATIVE AIR MACHINE
NEGATIVE PRESSURE ENCLOSURE BOUNDARY
WLO
ER
SR
CR
jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Rectangle jrhyn Line jrhyn Polygonal Line jrhyn Callout
LEAVE STAIRWELL UNOBSTRUCTED FOR EMERGENCY EGRESS BY OCCUPANTS DURING ABATEMENT
jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn Polygonal Line jrhyn
CENTRAL STAIRWELL TO BE USED AS PRIMARY EGRESS FOR OCCUPANTS DURING ABATEMENT
| 01 - Cover Sheet |
| 02- HazMat |
| Untitled |
| 03 - Structural |
| S-001 |
| S-501 |
| S-502 |
| 04 - Architectural |
| A-111 |
| A-121 |
| A-131 |
| 05 - Mechanical |
| M-001 |
| M-002 |
| MD-101 |
| MD-111 |
| MD-121 |
| MD-131 |
| M-101 |
| M-111 |
| M-121 |
| M-131 |
| M-501 |
| M-502 |
| M-503 |
| M-601 |
| M-601A |
| M-602 |
| M-701 |
| M-702 |
| M-703 |
| M-801 |
| M-802 |
| M-803 |
| M-804 |
| M-805 |
| 06 - Electrical |
| E-001 |
| E-002 |
| ED101 |
| ED111 |
| ED121 |
| ED131 |
| EP101 |
| EP111 |
| EP121 |
| EP131 |
| E-501 |
| E-601 |
| E-701 |
File details come from the government source that posted it.