3 Copy of Asbestos Six Month Assessment.pdf
PDF 299 KB Posted
- Attached to
- F101--Airborne Asbestos Mold Monitoring (550)
- Solicitation number
- 36C25224Q0468
About this file
This document is a government file related to an asbestos and mold assessment and monitoring contract opportunity. The key details are:
The federal contract opportunity is for Airborne Asbestos Mold Monitoring (Solicitation Number: 36C25224Q0468) issued by the Department of Veterans Affairs (VA) Veterans Health Administration, Veterans Integrated Service Network 12. The required services include asbestos and mold air testing and monitoring. The document provides detailed information on the locations, materials, and conditions of asbestos-containing materials across multiple VA buildings. This information appears to be used to support the requirements of the solicitation. No additional details on the contract's pricing, set-asides, award dates, or incumbents are provided in the document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25224Q0468 0003.docx | DOCX document | |
| 4 Station 550 Bldg Inventory - Asbestos Surveys.pdf | ||
| 2 Danville VAMC - Asbestos Reinspection Report_Redacted.pdf | ||
| 36C25224Q0468 0002.docx | DOCX document | |
| 36C25224Q0468 0001.docx | DOCX document | |
| P07 Vermilion IL WD 2015 5021 Rev 22 dated 05 10 2024.pdf | ||
| 36C25224Q0468.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contact Vibration Air Erosion
Floor Mastic Under Tile Black Basement and 1st
350 SF
NO Good 1
Low High Low
1st floor abated save for east foyer.
Basement significant damage 5 Floor Tile 9”x9” (Does Not Include Mastic) Green
1st
450 SF
NO
Significantly
Damaged 1
High High Low
1st floor abated save for east foyer.
Basement significant damage
Floor Mastic Under Black Tile 1st
450 SF NO Good 1
Low High Low
Abated save for east foyer
10 Piping Insulation Magnesia-Type (Heating System) basement
200 SF
NO Good 1
Low High High
Damaged, partially remediated
11 Piping Insulation Aircell -Type (Domestic Water) basement
250 SF
NO Good 1
Low High High
Damaged, partially remediated
12 Piping Fitting Insulation On Magnesia-Type (Heating System) basement
10 EA
NO Good 1
Low High High
Damaged, partially remediated
17 Piping Insulation Magnesia-Type (Heating System) firedoor basement
1 EA
Yes Damaged 4
Low High High
Repaired
Exterior window glazing basement and 1st
2000 LF
NO Good 1
Low High Low
Some damage on a few windows exterior paint white.
10000 SF
Yes Damaged 4
Low High High
Painted over
Contact Vibration Air Erosion
2 Floor Mastic Under Tile Black second floor 2600 SF
NO Good 1
Low High Low
ABATED
4 Floor Mastic Under Tile Black fifth floor 520 SF
NO Good 1
Low High Low
GOOD
Floor Tile 9"X9" (Does Not Include Mastic) Tan, Brown & Green Basement through fifth
19000 SF NO Good 1
High High High
Basement damaged,1-3 abated.
Some 9x9 remains in path lab. 9x9 remains in some stair wells, all in good condition
16 Floor Mastic Under Tile Black 1st through 5th 19000 SF
NO Good 1
Low High Low
1-3 abated
17 Floor Tile 12"X12" (Does Not Include Mastic) Light Tan 2nd
600 SF
NO
ABATED
29 Mastic On Sink Black 1st through 5th 7 EA NO Good 1 Low High Low 3 Several damaged
32 Piping Insulation Magnesia-Type (Heating System) crawlspace and attic
3000 LF
Yes Damaged 4
Low High High
Attic 90% abated, remainder damaged. crawl space unchanged, significantly damaged
33 Piping Insulation Aircell-Type (Domestic Waterline) crawlspace
350 LF
Yes Damaged 4
Low High High
Unchanged, damaged
34 Tank Insulation White 3rd floor 300 SF
Yes Damaged 4
Low High High
ABATED
36 Debris Soil Debris (MAG) crawlspace 12500 SF
Yes Damaged 4
Low High High
Unchanged; damaged
37 Thermal Taping Compound Tape attic 7000 SF
Yes Damaged 4
Low High High
90% abated, remainder damaged
38 Pipe Support Insulation On Fiberglass Insulated Lines attic
350 EA
Yes Damaged 4
Low High High
90% abated; remainder damaged
Pipe Fitting Insulation On Fiberglass Run (Chilled Waterline) crawlspace and attic
500 EA Yes Damaged 4
Low High High
Attic 90% abated, remainder damaged. Crawlspaace unchanged, significantly damaged
42 Caulking/Putties Fire Stop, On Fan Coil Unit exterior windows
400 LF
NO Good 1
Low High High
Several damaged
Material Description Approximate Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Disturbance Potential
Building 22
Building 58
Homgenous Area Number August 2016 Inspection
Homgenous Area Number
HAZARD
RANKINGMaterial Description Approximate
Quanity
CURRENT
CLASSIFICATI
ON
FRIABLE
43 Floor Mastic Under Tile Black 5th floor 500 SF
NO Good 1
Low High Low
Good
45 Floor Mastic Under Tile Black 2nd floor 600 SF
NO
ABATED
Pipe Fitting Insulation On Blk Styrofoam Lines (Domestic/Chilled Lines) basement 40 EA Yes Damaged 4
Low High High
Damaged
Floor Tile 12"X12" (Does Not Include Mastic) Tan With Brown & Yellow Streaks basement 500 SF NO Good 1
High High High
Damaged
Elevator Brake Shoes attic
10 SF NO Good 1
High High High
Good
Contact Vibration Air Erosion
Floor Tile 12"X12" (Does Not Include Mastic) White With Grey Streaks 18 SF NO Good 1
High High High
Good Condition
4 Floor Mastic Under Tile Black 18 SF
NO Good 1
Low High Low
Good Condition
Floor Tile 12"X12" (Does Not Include Mastic) White With Brown Streaks 120 SF NO Good 1
High High High
Good Condition
6 Floor Mastic Under Tile Black 120 SF
NO Good 1
Low High Low
Good Condition
7 Vinyl Sheet Flooring (Does Not Include Mastic) Brown
300 SF
Yes Damaged 4
Low High High
Good Condition
16 Piping Insulation Aircell-Type (Heating System) 140 LF
NO Good 1
Low High High
Damaged in attic, partially abated
18 Floor Mastic Under Tile Black 300 SF
NO Good 1
Low High Low
Good Condition
Contact Vibration Air Erosion
3 Floor Mastic under tile Black 220 SF
NO Good 1
Low High Low
3 Damaged 6 Piping insulation Magnesia-Type (Heating System) 400 LF
Yes Damaged 4
Low High High
6 Damaged 7 PipingInsulation, Aircell-Type 100 LF
NO Damaged 4
Low High High
6 Damaged 10 Debris Pipe Debris In Soil 60 SF
Yes Removed 11 Floor Mastic under tile Black 500 SF
NO Good 1
Low High Low
3 Damaged 15 Textured paint Exterior Paint (White) 10000 SF
NO Good 1
High High High
3 Painted over
Contact Vibration Air Erosion
1 Floor Tile 12"x12" (does not include mastic) Tan 800 SF NO Good 1
High High High
Good Condition
3 Floor Tile 12"x12" (does not include mastic) Gray 90 SF NO Good 1
High High High
Good Condition
16 Piping insulation Aircell-Type (Heating System) 200 LF Yes Good 2
Low High High
Good, appears to have been partially abated
21 Window caulking Window Glazing (Gray) 1500 LF NO Good 1 Moderate High High 3 Good Condition
Contact Vibration Air Erosion
Building 98
CURRENT
CLASSIFICATI
ON
Building 72
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Building 69
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Building 64
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 InspectionHomgenous
Area Number Material Description Approximate Quanity FRIABLE
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 InspectionFRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Homgenous Area Number Material Description Approximate
Quanity
8 Floor Mastic Under Tile Black 2nd floor 1800 SF
Low High Low
Abated, although some 12x12 floor tile still exists in remote areas, all in good condition
15 Floor Tile 12"X12" (Does Not Include Mastic) Tan Elevators
130 SF
NO Good 1
High High High
ABATED
16 Floor Mastic Under Tile Black Elevators 130 SF
NO Good 1
Low High Low
ABATED
17 Floor Tile 9"X9" (Does Not Include Mastic) Tan Basement, 2nd, 3rd
6000 SF
NO Good 1
High High High
12x12 in basement, on third floor, and remote areas of 1st and 2nd floor. All in good condition
18 Floor Mastic Under Tile Black Basement, 2nd, 3rd 6000 SF
NO Good 1
Low High Low
See above
21 Piping Insulation Magnesia-Type (Heating System) Basement
350 LF
Yes Damaged 4
Low High High
In locked crawl space. Significantly damaged 22 Emergency Generator Muffler Insulation Grey
Generator Room
100 SF
Yes Damaged 4
Low Low Low
Repaired. Not marked as containing or not containing asbestos 30 Debris Soil Debris (MAG) Basement 10000 SF
Yes Damaged 4
Low High High
In locked crawl space. Significantly damaged 32 Firestop Caulking/Putties On Fan Coil Unit Exterior
Windows
250 LF
NO Good 1
Low High High
Visible damage to exterior window caulking on 2nd and 3rd floor. First floor in good condition.
35 Pipe Fitting Insulation On Roof Drain Penthouse 12 EA
Yes Damaged 4
Low High High
Damaged
Pipe Fitting Insulation On Fiberglass Run (Domestic & Chilled Water Line) Basement, 1st, 2nd, Penthouse 80 EA Yes Damaged 4
Low High High
Penthouse in good condition
37 Pipe Fitting Insulation On Foam Rubber Piping Insulation Basement 1st, 2nd, Penthouse
600 EA
Yes Damaged 4
Low High High
Damaged
Elevator Brake Shoes Penthouse
10 SF NO Good 1
High High High
Good Condition
Contact Vibration Air Erosion
23 Joint Compound On Gypsum Board White 2500 SF
NO Good 1
Moderate m Low
Abated as part of halls and walls project??
Pipe Fitting Insulation On Fiberglass Line (Htg, Domes/Chilled Water Line)
1500 EA Yes Damaged 4
Low High High
Still damaged throughout. Some piece meal abatement has occurred in respnse to specific issues.
26 Tank Insulation Gray 120 SF
NO
Significantly
Damaged 1
Moderate Low Low
?? There is a tank in utility room that has fresher insulation on it. Uitlity room appears to have had fairly recent abatement performed 27 Window Caulking Exterior Window Glazing 8000 LF
NO Good 1
Low Moderate High
Good. Some minor damage in peace garden 29 Piping Insulation Roof Drain Insulation (Asumed) 15 LF
Yes Damaged 4
Low High Low
3 Damaged
Contact Vibration Air Erosion
2 Floor Mastic on HA#1 1000SF
NO Good 1
Low High Low
Approximately 50% abated, 50%good 5 Floor Tile 12"X12", 1000 SF
NO Good 1
High High High
Approximately 50% abated, 50%good 7 Floor Tile 9"X9" (Does Not Include Mastic) Tan 15,450 SF
NO Good 1
High High High
Abated
8 Mastic under Floor Tile 9"X9" 15,450 SF
NO Good 1
Low High Low
Abated
Building 102
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Building 101
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
12&13 Viny Sheet Flooring, Brown Mastic 1000 SF
High High High
Could not locate. Abated?
Pipe Fitting Insulation On Fiberglass Run (Htg, Domes/Chilled Water Line) 300 EA Yes Damaged 4
Low High High
Damaged
27 Window Caulking Gray 8000 LF
Yes Damaged 4
Low High High
Appears to have been repaired at some point 28 Window Caulking Gray 200 LF
NO Good 1
Low Moderate High
Good
106 Mastic on Fan Coil Unit 75 SF
NO Good 1
Low High High
Good
202 Mastic under gold sheet flooring 750 LF
NO Good 1
Low High Low
Could not locate. Abated?
Contact Vibration Air Erosion
19 Pipe Fitting Insulation On Fiberglass Run (Htg, Dome 1300 EA Yes Damaged 4 Low High high 6 Per notations on drawings, information on this insulation was provided to thew contractor by the VA and not examined in either the 2010 or 2007 assessments. Disagree that it can be classified as damaged.
Disagree that it is one homgeneous area.
Contact Vibration Air Erosion
2 Floor Mastic Under Tile Black 5800 SF
NO Good 1
Low High Low
Hallways abated, some floor tiles remain in offices.
4 Floor Mastic Under Tile Black 1500 SF
NO Good 1
Low High Low
Hallways abated, some floor tiles remain in offices.
6 Floor Mastic Under Tile Black 5000 SF
NO Good 1
Low High Low
Hallways abated, some floor tiles remain in offices.
7 Floor Tilw 12"x12", Orange/Mastic 500 SF
NO Good 1
High High High
Hallways abated, some floor tiles remain in offices.
8 Floor Tile 9"X9" (Does Not Include Mastic) Tan 13400 SF
NO Good 1
High High High
Abated
9 Floor Tile 9"X9" (Does Not Include Mastic) Black 13400 SF
NO Good 1
High High High
Abated
12 Floor Mastic Under Tile Black 2000 SF
NO Good 1
Low High Low
Abated
Pipe Fitting Insulation On Fiberglass Run (Heating & Domestic Waterline) 450 EA Yes Damaged 4
Low High High
Approximately 75% abated, 25 % damaged 17 Ceiling Tile 1'x1' (Spline System) Pinhole 3500 SF
Yes Damaged 4
Low High High
Abated
18 Mastic On Sink Black 3 EA
NO Good 1
Low High Low
Good
19 Transite-Type Panels 1200 SF
NO Good 1
Low High High
Good, but not all is transite
20 Tank Insulation Gray 50 SF
Yes Damaged 4
Moderate Low Moderate
Removed
Generator Insulation Emergency Muffler Generator Insulation 300 SF Yes Damaged 4
Low High High
Damaged
103 Vibration Dampening cloth 25 SF
NO Good 1
Low High High
Good
Building 104
Building 103
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKING
Disturbance Potential POTENTIAL
HAZARD
August 2016 Inspection
Remarks Contact Vibration Air
Erosion Mar-17
2 Floor Mastic Under Tile Black second floor
2600 SF
NO Good 1
Low High Low
ABATED Abated
4 Floor Mastic Under Tile Black fifth floor
520 SF
NO Good 1
Low High Low
GOOD Good
Floor Tile 9"X9" (Does Not Include Mastic) Tan, Brown & Green Basement through fifth 19000 SF NO Good 1
High High High
Basement damaged,1-3 abated. Some 9x9 remains in path lab. 9x9 remains in some stair wells, all in good condition
No changes except West stairwell 1st floor damaged 9x9. Recommend removal
16 Floor Mastic Under Tile Black 1st through 5th
19000 SF
NO Good 1
Low High Low
1-3 abated 4-5 Good
17 Floor Tile 12"X12" (Does Not Include Mastic) Light Tan 2nd
600 SF
NO
ABATED Abated
29 Mastic On Sink Black 1st through 5th
7 EA
NO Good 1
Low High Low
Several damaged No Change
32 Piping Insulation Magnesia- Type (Heating System) crawlspace and attic
3000 LF
Yes Damaged 4
Low High High
Attic 90% abated, remainder damaged.
crawl space unchanged, damaged
No Change
33 Piping Insulation Aircell-Type (Domestic Waterline) crawlspace
350 LF
Yes Damaged 4
Low High High
Unchanged, damaged Unchanged, damaged
34 Tank Insulation White 3rd floor
300 SF
Yes Damaged 4
Low High High
ABATED Abated
36 Debris Soil Debris (MAG) crawlspace
12500 SF
Yes Damaged 4
Low High High
Unchanged; damaged Unchanged, dmaged
37 Thermal Taping Compound Tape attic
7000 SF
Yes Damaged 4
Low High High
90% abated, remainder damaged Unchanged
38 Pipe Support Insulation On Fiberglass Insulated Lines attic
350 EA
Yes Damaged 4
Low High High
90% abated; remainder damaged Unchanged
Pipe Fitting Insulation On Fiberglass Run (Chilled Waterline) crawlspace and attic 500 EA Yes Damaged 4
Low High High
Attic 90% abated, remainder damaged.
Crawlspaace unchanged, damaged
Unchanged
42 Caulking/Putties Fire Stop, On Fan Coil Unit exterior windows
400 LF
NO Good 1
Low High High
Several damaged Several damaged
43 Floor Mastic Under Tile Black 5th floor
500 SF
NO Good 1
Low High Low
Good Good
45 Floor Mastic Under Tile Black 2nd floor
600 SF
NO
ABATED Abated
Pipe Fitting Insulation On Blk Styrofoam Lines (Domestic/Chilled Lines) basement 40 EA Yes Damaged 4
Low High High
Damaged Damaged
Floor Tile 12"X12" (Does Not Include Mastic) Tan With Brown & Yellow Streaks basement 500 SF NO Good 1
High High High
Damaged Damaged
102 Elevator Brake Shoes attic 10 SF NO Good 1 High High High 3 Good Good
Disturbance Potential POTENTIAL
HAZARD
RANKING
REMARKS August 2017
Homgenous Area Number Material Description
Approxim ate
Quanity
FRIABLE
CURRENT
CLASSIFICATI
ON
HAZARD
RANKIN
G
Erosion
Floor Mastic Under Tile Black 2nd floor 1800 SF NO Good 1 Low High Low 3
Abated, although some 12x12 floor tile still exists in remote areas, all in good condition
Floor Tile 12"X12" (Does Not Include Mastic) Tan Elevators 130 SF NO Good 1 High High High 3
ABATED
Floor Mastic Under Tile Black Elevators 130 SF NO Good 1 Low High Low 3
ABATED
Floor Tile 9"X9" (Does Not Include Mastic) Tan Basement, 2nd, 3rd 6000 SF NO Good 1 High High High 3
12x12 in basement, on third floor, and remote areas of 1st and 2nd floor
Floor Mastic Under Tile Black Basement, 2nd, 3rd 6000 SF NO Good 1 Low High Low 3
See above
Piping Insulation Magnesia-Type (Heating System) Basement 350 LF Yes Damaged 4 Low High High 6
In locked crawl space. Extensively damaged
Emergency Generator Muffler Insulation Grey Generator Room 100 SF Yes Damaged 5 Low High Low 5
Repaired. Not marked as containing or not containing asbestos
Debris Soil Debris (MAG) Basement 10000 SF Yes Damaged 4 Low High High 6
In locked crawl space. Extensively damaged
Firestop Caulking/Putties On Fan Coil Unit Exterior Windows 250 LF NO Good 1 Low High High 3
Visible damage to exterior window caulking on 2nd and 3rd floor. First floor in good condition.
Pipe Fitting Insulation On Roof Drain Penthouse 12 EA Yes Damaged 4 Low High High 6
Damaged
Pipe Fitting Insulation On Fiberglass Run (Domestic & Chilled Water Line) Basement, 1st, 2nd, Penthouse 80 EA Yes Damaged 4 Low High High 6
Penthouse in good condition
Pipe Fitting Insulation On Foam Rubber Piping Insulation Basement 1st, 2nd, Penthouse 600 EA Yes Damaged 4 Low High High 6
Damaged
102 Elevator Brake Shoes Penthouse 10 SF NO Good 1 High High High 3
Good Condition
Disturbance Potential POTENTI
AL
HAZARD
REMARKS
Building 98
Homgeno us Area Number
Material Description Approxim ate Quanity
FRIABLE CURRENT
CLASSIFICATION
HAZARD
Aug-16 Mar-17
Erosion
2 Floor Mastic Under Tile Black Basement and 1st
350 SF NO Good 1 Low High Low 6 1st floor abated save for east foyer.
Basement significant damage
Significantly Damaged
Significantly Damaged
5 Floor Tile 9”x9” (Does Not Include Mastic) Green 1st
450 SF NO Significantly Damaged 1 High High Low 7 1st floor abated save for east foyer.
Basement significant damage Good Good
Floor Mastic Under Black Tile
1st 450 SF NO Good 1 Low High Low 3 Abated save for east foyer Good Good
10 Piping Insulation Magnesia-Type
(Heating System) basement
200 SF NO Good 1 Low High High 3 Damaged, partially remediated Good Good
11 Piping Insulation Aircell -Type
(Domestic Water) basement
250 SF NO Good 1 Low High High 3 Damaged, partially remediated Good Damaged
12 Piping Fitting Insulation On
Magnesia-Type (Heating System) basement
10 EA NO Good 1 Low High High 3 Damaged, partially remediated Good Damaged
17 Piping Insulation Magnesia-Type
(Heating System) firedoor basement
1 EA Yes Good 4 Low High High 3 Repaired Good Good
18 Exterior window glazing basement and 1st 2000 LF NO Good 1 Low High Low 3 Some damage on a few windows Good Good
19 exteerior pain white. 10000 SF Yes Good 4 Low High High 3 Painted over Good Good
Disturbance Potential POTENTI
AL
HAZARD
REMARKS
Building 22
Homgenous Area Number
Material Description
Approximate Quanity FRIABLE
CURRENT
CLASSIFICA
TION
HAZARD
Aug-16 Feb-17
3 Floor Tile 12"X12" (Does Not Include
Mastic) White With Grey Streaks
18 SF NO Good 1 High High High 3 Good Condition Good Condition
4 Floor Mastic Under Tile Black
18 SF NO Good 1 Low High Low 3 Good Condition Good Condition
5 Floor Tile 12"X12" (Does Not Include
Mastic) White With Brown Streaks
120 SF NO Good 1 High High High 3 Good Condition Good Condition
6 Floor Mastic Under Tile Black
120 SF NO Good 1 Low High Low 3 Good Condition Good Condition
7 Vinyl Sheet Flooring (Does Not
Include Mastic) Brown
300 SF Yes Damaged 4 Low High High 6 Good Condition Good Condition
16 Piping Insulation Aircell-Type
(Heating System)
140 LF NO Good 1 Low High High 3 Damaged in attic, partially abated Damaged in attic,may need further abatement.
18 Floor Mastic Under Tile Black
300 SF NO Good 1 Low High Low 3 Good Condition Good Condition
Contact Vibration Air Erosion
1 Floor Tile 12"x12" (does not include mastic) Tan
800 SF NO Good 1 High High High 3 Good Condition Good Condition
3 Floor Tile 12"x12" (does not include mastic) Gray
90 SF NO Good 1 High High High 3 Good Condition Good Condition
16 Piping insulation Aircell-Type
(Heating System)
200 LF Yes Good 2 Low High High 3 Good, appears to have been partially abated
Good, appears to have been partially abated
21 Window caulking Window Glazing
(Gray)
1500 LF NO Good 1 Moderate High High 3 Good Condition Good Condition
REMARKS
Building 72
Disturbance Potential POTENTIAL
HAZARD
RANKING
REMARKS
Building 64
Homgenous Area Number
Material Description
Approximate Quanity
FRIABLE CURRENT
CLASSIFICA
TION
HAZARD
RANKIN
G
Homgenous Area Number
Material Description
Approximate Quanity FRIABLE
CURRENT
CLASSIFICA
TION
HAZARD
RANKIN
G
Disturbance Potential POTENTIAL
HAZARD
23 Joint Compound On Gypsum Board White Throughout
2500 SF
NO Good 1
Moderate m Low
Abated as part of halls and walls project??
Pipe Fitting Insulation On Fiberglass Line (Htg, Domes/Chilled Water Line) Throughout, see diagrams
1500 EA Yes Damaged 4
Low High High
Still damaged throughout. Some piece meal abatement has occurred in response to specific issues.
26 Tank Insulation Gray
120 SF
NO
Significantly Damaged 1
Moderate Low Low
?? There is a tank in utility room that has fresher insulation on it. Uitlity room appears to have had fairly recent abatement performed 27 Window Caulking
Exterior Window Glazing
8000 LF
NO Good 1
Low Moderate High
Good. Some minor damage in peace garden 29 Piping Insulation
Roof Drain Insulation (Assumed)
15 LF
Yes Damaged 4
Low High Low
3 Damaged
Disturbance Potential POTENTI
AL
HAZARD
August 2016 Inspection
Building 101
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICAT
ION
HAZARD
19 Pipe Fitting Insulation O 1300 EA Yes Damaged 4 Low High high 6 Per notations on drawings, information on this insulation was provided to thew contractor by the VA and not examind in either the 2010 or 2007 assessments. Disagree that it can be classified as damaged. Disagree that it is one homgeneous area.
Disturbance Potential POTENTI
AL
HAZARD
August 2016 Inspection
Building 103
Homgenous Area Number Material Description Approximate
Quanity FRIABLE
CURRENT
CLASSIFICAT
ION
HAZARD
Erosion Mar-17
3 Floor Mastic under tile Black
220 SF
NO Good 1
Low High Low 3 Damaged Damaged
6 Piping insulation Magnesia-Type (Heating System)
400 LF
Yes Damaged 4
Low High High
6 Damaged Damaged 7 PipingInsulation, Aircell-Type
100 LF
NO Damaged 4 Low High High
6 Damaged Damaged 10 Debris Pipe
Debris In Soil
60 SF
Yes Removed Removed 11 Floor Mastic under tile Black
500 SF
NO Good 1 Low High Low
3 Damaged Damaged 15 Textured paint
Exterior Paint (White)
10000 SF
NO Good 1
High High High
3 Painted over Painted over
Disturbance Potential POTENTIA
L HAZARD
RANKING
August 2016 Inspection
Building 69
Homgenous Area Number
Material Description
Approximate Quanity FRIABLE CURRENT
CLASSIFICATION
HAZARD
2 Floor Mastic on
HA#1
1000SF NO Good 1 Low High Low 3 Approximately 50% abated, 50%good Approximately 50% abated, 50%good
5 Floor Tile 12"X12", 1000 SF NO Good 1 High High High 3 Approximately 50% abated, 50%good Approximately 50% abated, 50%good
7 Floor Tile 9"X9" (Does Not Include Mastic) Tan
15,450 SF NO Good 1 High High High 3 Abated Abated
8 Mastic under Floor Tile 9"X9"
15,450 SF NO Good 1 Low High Low 3 Abated Abated
12&13 Viny Sheet Flooring, Brown Mastic
1000 SF NO Good 1 High High High 3 Could not locate. Abated? Could not locate.
Abated?
Pipe Fitting Insulation On Fiberglass Run (Htg, Domes/Chilled Water Line)
300 EA Yes Damaged 4 Low High High 6 Damaged
27 Window Caulking Gray
8000 LF Yes Damaged 4 Low High High 6 Appears to have been repaired at some point
28 Window Caulking Gray
200 LF NO Good 1 Low Moderate High 3 Good
106 Mastic on Fan Coil Unit
75 SF NO Good 1 Low High High 3 Good
202 Mastic under gold sheet flooring
750 LF NO Good 1 Low High Low 3 Could not locate. Abated? Could not locate.
Abated?
Disturbance Potential POTENTIA
L HAZARD
RANKING
August 2016 Inspection
Building 102
Homgenous Area Number
Material Description
Approximate Quanity FRIABLE
CURRENT
CLASSIFICATIO
N
HAZARD
2 Floor Mastic Under Tile Black
5800 SF NO Good 1 Low High Low 3 Hallways abated, some floor tiles remain in offices.
Hallways abated, some floor tiles remain in offices.
4 Floor Mastic Under Tile Black
1500 SF NO Good 1 Low High Low 3 Hallways abated, some floor tiles remain in offices.
Hallways abated, some floor tiles remain in offices.
6 Floor Mastic Under Tile Black
5000 SF NO Good 1 Low High Low 3 Hallways abated, some floor tiles remain in offices.
Hallways abated, some floor tiles remain in offices.
7 Floor Tilw 12"x12", Orange/Mastic
500 SF NO Good 1 High High High 3 Hallways abated, some floor tiles remain in offices.
Hallways abated, some floor tiles remain in offices.
8 Floor Tile 9"X9" (Does Not Include Mastic) Tan
13400 SF NO Good 1 High High High 3 Abated Abated
9 Floor Tile 9"X9" (Does Not Include Mastic) Black
13400 SF NO Good 1 High High High 3 Abated Abated
12 Floor Mastic Under Tile Black
2000 SF NO Good 1 Low High Low 3 Abated Abated
14 Pipe Fitting Insulation On Fiberglass Run (Heating & Domestic Waterline)
450 EA Yes Damaged 4 Low High High 6 Approximately 75% abated, 25 % damaged
Approximately 75% abated, 25 % damaged
17 Ceiling Tile 1'x1' (Spline System) Pinhole
3500 SF Yes Damaged 4 Low High High 6 Abated Abated
18 Mastic On Sink Black
3 EA NO Good 1 Low High Low 3 Good Good
19 Transite-Type Panels
1200 SF NO Good 1 Low High High 3 Good, but not all is transite Good, but not all is transite
20 Tank Insulation Gray
50 SF Yes Damaged 4 Moderate Low Moderate 5 Removed Removed
21 Generator Insulation Emergency Muffler Generator Insulation
300 SF Yes Damaged 4 Low High High 6 Damaged Damaged
103 Vibration Dampening cloth
25 SF NO Good 1 Low High High 3 Good Good
Disturbance Potential POTENTIAL
HAZARD
RANKING
August 2016 Inspection
Building 104
Homgenous Area Number
Material Description
Approximate Quanity FRIABLE CURRENT
CLASSIFICATION
HAZARD
| All Buildings |
| 58 |
| 98 |
| 22 |
| 64-72 |
| 101 |
| 103 |
| 69 |
| 102 |
| 104 |