S06 - Firestop_SingleSourceJustification_MPT-SAT.pdf

PDF 195 KB Posted

Attached to
Z1DA--695-22-111 (CON) Replace EP Lab Server Room AHU
Solicitation number
36C25223B0007
Issued by

About this file

This single source justification document from the Department of Veterans Affairs requests approval to award a sole source contract to HILTI for firestop systems materials and services. The requesting agency needs to purchase HILTI's firestop products estimated at $12,500 to match existing firestop systems throughout the medical center and ensure all assemblies are UL approved. A switch to other manufacturers' incompatible systems would void UL ratings and require removing and replacing entire firestop installations. Market research found HILTI to be the standard and no other systems are compatible with the existing HILTI products used across penetrations in walls, ceilings and floors. The contracting officer certified the single source justification as accurate.

The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Veterans Health Administration to replace the EP Lab server room air handling unit for $695,232.60.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT

VHAPM Part 813.106 Page 1 of 1 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020

DEPARTMENT OF VETERANS AFFAIRS

Justification for Single Source Awards IAW FAR 13.106‐1 For

Over Micro‐Purchase Threshold but Not Exceeding the SAT ($250K)

Acquisition Plan Action ID: 36C252‐23‐AP‐0579

1. Contracting Activity: Department of Veterans Affairs, Great Lakes Acquisition Center, NCO 12, 115 South

84th Street, Milwaukee, WI 53214. Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J.

Zablocki VA Medical Center, 5000 W. National Avenue, Milwaukee WI 53295. Purchase Request (2237) number: 695‐23‐2‐6085‐0002.

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

This product, HILTI Firestop Systems, is an integration of materials, assemblies and components to provide firestopping to prevent fire from spreading through penetrations in walls, ceiling and floors throughout the medical center.

The estimated expected cost for HILTI Firestop Systems material is $12,500.

3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:

Firestopping is achieved through assemblies, not just materials and it is imperative approved assemblies are used and the assemblies are the same throughout the hospital to allow for inspections and adequate compliance when The Joint Commission and VA inspect for accreditation of the hospital and the safety of patients and staff. It is necessary to match existing systems to ensure there are no interface problems, approved assemblies are used in lieu just materials and all systems are UL approved.

4. Description of market research conducted and results or statement why it was not conducted:

We established HILTI as our standard. The other Firestop systems on the market are not compatible with

HILTI. The products cannot be mixed together in a penetration because this voids the UL rating required.

Were to switch systems we would not be able to maintain the existing firestop in the hospital and would be forced to remove and replace entire systems.

5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106‐1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

Ryan McMillin Date Contracting Officer

File details come from the government source that posted it. Updated .