This document contains a pre-solicitation notice and federal contract opportunity for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 is seeking to construct a new water softening plant building at the VA Illiana Health Care System campus in Danville, Illinois to serve the entire facility. The solicitation will be issued on August 10th, 2021 with bids due by September 9th, 2021. The construction period is 180 calendar days with a budget between $1 million to $5 million. The project involves building a new structure to house primary and backup water softening systems including three months of brine storage. The NAICS code is 237110 and it is set aside for Service-Disabled Veteran-Owned Small Businesses. A pre-bid conference will be held on August 19th for all prospective bidders. Interested parties should monitor SAM.gov for the full solicitation and any amendments.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOF EAVE
115' - 10"
C
1 1/2" STANDING SEAM ROOF OVER VINYL
BAGGED BATT INSULATION TO MEET
SPECIFICATION
GUTTER HANGER
PER MANUFACTURERS STANDARD
PREFINISHED METAL GUTTER
EAVE CLOSURE
GUTTER APRON
EAVE STRUT
C PURLIN PER
MANUFACTURES
STANDARD
1 1/2" CORRUGATED METAL PANEL OVER
VINYL BAGGED BATT INSULATION TO
MEET SPECIFICATIONS
SNOW GUARD SYSTEM PER
MANUFACTURER'S STANDARD
LIGHTING PROTECTION SYSTEM, INSTALL PER
MANUFACTURER'S RECOMMENDATION - SEE
ELECTRICAL FOR MORE INFORMATION.
FLOOR
100' - 0"
C
GRADE
99' - 6"
1 1/2" RIGID INSULATION TURNED
DOWN TO FOOTING AND TURNED
BACK 2'-0" ENTIRE PERIMENTER
OF BUILDING
TYPICAL
2' - 0"
DRAINAGE MAT
1 1/2" CORRUGATED METAL
PANEL OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
6" CONCRETE ON
10 MIL VAPOR BARRIER ON
6" GRAVEL BASE
1/2" COMPRESSIBLE JOINT FILLER
CLOSER STRIP
Z GIRT PER MANUFACTURERS STANDARD
CM-1
BK-1
1' - 7" 5"
GRADING SLOPING AWAY FROM BUILDING -
REFER TO CIVIL DRAWINGS
5"
FLASHING
MORTAR NET
BRICK LEDGE
MASONRY TIE
16" O.C. HORIZONTALLY AND VERTICALLY
BRICK VENEER ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
FLASHING, COLOR TO MATCH METAL PANEL (CM-1)
B R
IC
K
V E
N E
E R
3'
C M
U B
A C
K U
P
2'
2' - 0"
P-1
7 5/8" 3" 1 3/4" 3 5/8"
8 3/8"
RAKE FLASHING - COLOR
TO MATCH ROOF (MR)
NAILING STRIP
STANDING SEAM
METAL ROOF (MR)
TREATED FASCIA
NAILER
PURLIN (BEYOND)
1 1/2" CORRUGATED METAL PANEL OVER
VINYL BAGGED BATT INSULATION TO
MEET SPECIFICATIONS
1 1/2" CORRUGATED METAL PANEL
CLOSER STRIP
M
IN6"
ALUMINUM DRIP EDGE
1 1/2" CORRUGATED METAL PANEL
OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONSVAPOR BARRIER TO
WRAP HEADER
METAL PANEL ATTACHED
TO STEEL ANGLE
CLOSER STRIP
END TRIM FLASHING -
COLOR TO MATCH (CM-1)
PREFINISHED WALL
LOUVER - COLOR TO
MATCH (CM-1)
ZEE GRIT FRAMMED
OPENING
V E
R
IF
Y S
IZ
E w / M
E C
H A
N
IC
A L
D R
A W
IN
G
S
CM-1
CM-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:1
:5
P
M
AE311
SECTION DETAILS
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 1 1/2" = 1'-0"AE311
2 TYPICAL EAVE DETAIL
SCALE: 1 1/2" = 1'-0"AE311
1 TYPICAL BASE OF WALL DETAIL
SCALE: 3" = 1'-0"AE311
3 TYPICAL RAKE DETAIL
SCALE: 3" = 1'-0"AE311
4 WALL LOUVER DETAIL