Attachment 1. Addendum 1 - Arch set.pdf
PDF 4 MB Posted
- Solicitation number
- 36C25221B0027
About this file
This pre-solicitation notice provides details for solicitation number 36C25221B0027 to construct a campus water softening plant. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 will issue a solicitation to construct a new building to house a water softening plant at the VA Illiana Health Care System campus in Danville, Illinois. The plant will allow for 100% backup capability and include storage for a three-month supply of brine. The period of performance is 180 calendar days from notice to proceed. The solicitation and drawings will be posted on SAM.gov. A pre-bid conference will be held on August 19 and attendance is strongly encouraged. Pursuant to Public Law 109-461, this procurement is set aside for service-disabled veteran-owned small businesses. Offerors must represent that they meet SDVOSB/VOSB eligibility requirements at the time of bid submission. The estimated value is between $1,000,000 and $5,000,000. The North American Industry Classification code is 237110 for water and sewer line and related structures construction, using the $39.5 million small business size standard. The solicitation will be issued on or about August 10, 2021 with bid opening on September 9, 2021.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET
LOCATION
DETAIL REFERENCE
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
N
NORTH ARROW
INCANDESCENT WALL MOUNTED LIGHTING
INCANDESCENT SURFACE MOUNT LIGHTING
SURFACE MOUNTED FLUORESCENT
RECESSED FLUORESCENT
HVAC RETURN AIR GRILLE
HVAC SUPPLY DIFFUSER
PENDANT LIGHT
ACCESS PANEL
EXIT LIGHTING
S
D
SPEAKER
SMOKE DETECTOR
INCANDESCENT RECESSED LIGHTING
A 9'-0"
CEILING TAG CEILING TYPE
FINISHED CEILING HEIGHT
REFER TO CEILING LEGEND FOR MORE
INFORMATION
EXTENT OF REVISION
REVISION SET
MECH/ELEC ITEMS: REFER TO MEP SHEETS AS APPLICABLE
DETAIL/DRAWING SCALE
TITLE OF DETAIL/DRAWING
DETAIL/DRAWING NUMBER
SHEET NUMBER
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APPD APPROVED
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ATCH ATTACHMENT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BEV BEVEL
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKG BLOCKING
BLKT BLANKET
BM BEAM OR BENCHMARK
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CELSIUS CHANNEL OR CHANNEL CELSIUS
C CONC CAST CONCRETE
C TO C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CLEANOUT
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CS CAST CONCRETE STONE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEG NEGATIVE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OR OUTSIDE DIMENSION
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OUT OUTLET
OZ OUNCE
PAR PARALLEL OR PARAPET
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND CEMENT
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY REFRIGERATION OR REFRIGERATION
REFRACTORY
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
YD YARD
YR YEAR
1. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION
MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL
DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
2. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
3. DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
4. CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH
OWNER’S REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED
WITH UTILITY SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY,
ACCESS CONTROL, ETC.
5. ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
6. DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH
THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS
AND THE SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,
ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
7. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE
FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK
THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF
WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY
CERTAIN SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
8. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
9. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING
AND MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING
CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. APPROVED
METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
10. MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS SHOW
INFORMATION IN A DIAGRAMMATIC FASHION WITHOUT DIMENSIONING. THE GENERAL
CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL MECHANICAL, PLUMBING
AND ELECTRICAL EQUIPMENT WITH RESPECT TO THE ARCHITECTURAL AND
STRUCTURAL DETAILING OF SHAFTS, CHASES, CEILING CONSTRUCTION, ETC.
11. CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR
MISSING DIMENSIONS.
12. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
13. THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
14. ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW
STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW STUDS OR COLUMN
GRID LINES UNLESS NOTED OTHERWISE.
15. FLOOR ELEVATION 100’-0” IS EQUAL TO THE FINISH FLOOR SLAB UNLESS OTHERWISE
NOTED.
16. ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.
17. CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS
“TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE
DETAIL, AREA, OR ITEM REFERENCED.
18. PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, MOUNTING,
INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.
19. INSTALLED WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED MATERIALS
AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF MATERIAL
DELIVERY, MOUNTING, INSTALLATION AND ROUGH IN.
20. FURNISHED WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND
EQUIPMENT TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
DELIVERY AND ROUGH-IN.
21. ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY
CALLED OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
22. ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO
UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO THE
OWNER.
24. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
25. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT
CONSTRUCTION, FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE
CONSTRUCTION SITE. ANY DAMAGE OR UNACCEPTABLE WEAR BY THE
CONSTRUCTION TEAM SHALL BE REPAIRED/REPLACED BY THE CONTRACTOR AT NO
COST TO THE OWNER.
26. IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT
DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER
QUALITY OF WORK, AS DETERMINED BY THE COR, SHALL BE PROVIDED.
27. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND COORDINATING HARDWARE,
ACCESS CONTROL AND AUTOMATIC OPERATORS ARE PROVIDED WITH COMPLETE
AND COMPATIBLE SYSTEMS REQUIRED FOR THEIR OPERATION. REFER TO DOOR
HARDWARE SCHEDULE, HARDWARE SPECIFICATIONS, AUTOMATIC OPERATOR
SPECIFICATIONS, ACCESS CONTROL SPECIFICATIONS AND ELECTRICAL DRAWINGS.
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL DIAGRAM OR DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOZ DOZEN
DN DOWN
DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
ETS EXPOSE TO STRUCTURE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR FIBERGLASS
REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FWC FABRIC WALLCOVERING
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER OR HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE OR LEFT HAND REVERSE
LATENT HEAT RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM OR MEDIUM MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE OR MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING OR MOTOR OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
BUILDING X
XXXX
X
XXXX
ELEVATION REFERENCES
NEW WALL
S3A.G
INDICATES STRUCTURAL MATERIAL
INDICATES NOMINAL SIZE
INDICATES STRUCTURE AND FINISH HEIGHTS
INDICATES QUALIFER
ROOM
ROOM TAG
NEW DOOR
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR OR SOAP
DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
S SOUTH
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL LNTL STEEL LINTEL
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
TA TOILET ACCESSORY
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL OR TEMPERATURE
CONTROL PANEL OR TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
REVISION TO PLAN CALLOUT
WALLS
DOOR TAG
KEY NOTE TAGS
WALL TAG : REFER TO WALL LEGEND FOR MORE INFORMATION
DOORS
PT-1
T
101 EQUIPMENT/FURNITURE TAG
FINISH INDICATION
GLAZING1
1 PLAN NOTE
ALTERNATE/BID DEDUCT ITEM
KEY NOTE SYMBOLS
CONSTRUCTION GENERAL NOTESARCHITECTURAL SYMBOLS
REFLECTED CEILING PLAN SYMBOLS
ARCHITECTURAL ABBREVIATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:2
P
M
AE001
ARCHITECTURAL SYMBOLS AND
ABBREVIATIONSGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
Revisions: Date:
A B C
2' - 0" 16' - 0" 16' - 0"
2'
AE201
AE201
AE201
AE201
1375 SF
WATER SOFTENER
PLANT
A1
SC
AE301
AE601
AE301
AE301
AE301
3'
M .R
.O
3'
/8
6' - 3 3/8"
M.R.O.
14' - 8 3/4"
AE601
AE601
SIM
A2
AE311
AE101
TYP
AE101
TYP
A1
A2
36' - 0"
G2
2' - 0"
P-1
P-1
2'
A. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION
AND ELECTRICAL DRAWINGS FOR COORDINATION ITEMS. COORDINATE AS
REQUIRED INCLUDING NECESSARY FRAMING, BLOCKING, ETC.
B. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA REQUIREMENTS.
C. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF
STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.
D. ALL DIMENSIONS SHOWN ARE TO FACE OF METAL PANEL WALL SYSTEM
UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATES AS "CLR" OR
"CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF
FINISH.
E. COLUMN DIMENSIONS ARE FOR REFERENCE - REFER TO STRUCTURAL
DRAWINGS.
ARCHITECTURAL GENERAL NOTES
ARCHITECTURAL PLAN NOTES
A1. MANUFACTURER'S STANDARD PREFINISHED METAL DOWNSPOUT
A2. DOWNSPOUT SPLASH BLOCK
A. ROOFING SUPPLIERS, MANUFACTURERS, & INSTALLERS SHALL REVIEW ALL
ROOFING DETAILS & ADVISE THE ARCHITECT ON ANY RECOMMENDED
CHANGES.
B. UNLESS NOTIFIED OTHERWISE, ROOFING SUPPLIERS, MANUFACTURERS
AND INSTALLERS WILL BE ASSUMED TO HAVE REVIEWED AND APPROVED
THE DETAILS SHOWN.
C. CONTRACTOR & ALL SUBTRADES SHALL BE AWARE & EXERCISE THE
NECESSARY CARE TO PREVENT DAMAGE TO OR PUNCTURE OF THE ROOF.
THIS SHALL INCLUDE ALL MATERIALS, TOOLS, DELETERIOUS MATERIALS.
D. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION
AND ELECTRICAL FOR ITEMS. COORDINATE AS REQUIRED INCLUDING
NECESSARY FRAMING, BLOCKING, ETC.
R1. MANUFACTURER'S STANDARD PREFINISHED METAL GUTTER
R2. MANUFACTURER'S STANDARD PREFINISHED METAL ROOFING PANEL
R3. PROVIDE MANUFACTURER'S STANDARD SNOW GUARD CONTINUOUSLY
ALONG ROOF LINE AT MANUFACTURER'S SPACING, LOCATION, AND
CONFIGURATION.
R4. LIGHTING PROTECTION SYSTEM, INSTALL PER MANUFACTURER'S
RECOMMENDATION - SEE ELECTRICAL FOR MORE INFORMATION.
ROOF GENERAL NOTES
ROOF PLAN NOTES
A B C
AE201
AE201
AE201
AE201
R1
R1
R2
AE301
RAKE RAKE
RAKE RAKE
AE311
AE311
TYP
2" / 12"
2" / 12"
R4
R4
R4
R3R3
AE301
AE301
AE601
AE301
C
BRICK ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
STRUCTURE
1 3/8"
3/
8"
3/
8"
W A
LL
1'
/8
5/
8" 3"
3/
8"
5/ 8"
8"
WALL
1' - 4"
7 5/8" 3" 1 3/4" 3 5/8"
2'
2' - 0"
P-1
C
1 3/8"
8"
WALL
1' - 4"
7 5/8" 3" 1 3/4"
3 5/8"
BRICK ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
STRUCTURE
2' - 0"
P-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:3
P
M
AE101
ARCHITECTURAL FLOOR PLAN &
ROOF PLANGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 1/4" = 1'-0"AE101
1 FLOOR PLAN
N
SCALE: 1/4" = 1'-0"AE101
2 ROOF PLAN
N
FINISH SCHEDULE
FINISH
MARK FINISH MANUFACTURER PATTERN/STYLE COLOR COMMENTS
P-1 PAINT PITTSBURG PAINTS PPG1025-1 COMMERCIAL WHITE CMU BLOCK AND WOOD CAP
SC SEALED CONCRETE
SCALE: 3/4" = 1'-0"AE101
3 TYPICAL MASONRY CORNER DETAIL
SCALE: 3/4" = 1'-0"AE101
4 TYPICAL MASONRY COLUMN DETAIL
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
ABC
1 1
GRADE
99' - 6"
CM-1
AE601
BK-1
2:12 ROOF SLOPE 2:12 ROOF SLOPE
2'
AE301
/2
EQ EQ
ALIGN
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
A B C
1 1
GRADE
99' - 6"
CM-1
BK-1
AE301
2:12 ROOF SLOPE
2:12 ROOF SLOPE
3'
/4
99 8
/2
5' - 2 3/4"
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
GRADE
99' - 6"
CM-1
MR
AE301
AE301
BK-1
3'
/4
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
1 2 3
GRADE
99' - 6"
CM-1
MR
AE301
AE301
BK-1
3'
/4
CORRUGATED METAL PANEL - BASIS OF
DESIGN - BUTLERIB ll: COOL COUNTRY
WHEAT
STANDING SEAM METAL ROOFING - BASIS OF
DESIGN - BUTLERIB ll: COOL SOLAR WHITE
CM-1
BK-1
MR
EXTERIOR FINISH LEGEND
1. MANUFACTURER'S STANDARD PREFINISHED METAL GUTTER (COLOR TO
MATCH METAL PANEL (CM-1))
2. MANUFACTURER'S STANDARD PREFINISHED METAL DOWNSPOUT (COLOR TO
MATCH METAL PANEL (CM-1))
3. COIL DOOR HOUSING - PAINT TO MATCH METAL PANEL (CM-1)
4. RAKE FLASHING - COLOR TO MATCH ROOFING (MR)
5. DOWNSPOUT SPLASH BLOCK
6. 3'-0" x 5'-0" METAL WALL LOUVER, REFER TO MEP DRAWINGS
7. CONCRETE PAD, REFER TO CIVIL DRAWINGS
8. LIGHTNING PROTECTION SYSTEM PER MANUFACTURER'S
RECOMMENDATION, REFER TO ELECTRICAL DRAWINGS
9. MANUFACTURER'S STANDARD SNOW GUARD
#SPECIFIC ELEVATION NOTES#
BRICK VENEER - BASIS OF DESIGN -
INDIANA BRICK COMPANY: SIOUX CITY
MOUNTIAN SHADOW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:3
P
M
AE201
BUILDING ELEVATIONS
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 1/4" = 1'-0"AE201
1 NORTH ELEVATION
SCALE: 1/4" = 1'-0"AE201
3 SOUTH ELEVATION
SCALE: 1/4" = 1'-0"AE201
2 EAST ELEVATION
SCALE: 1/4" = 1'-0"AE201
4 WEST ELEVATION
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
A B C
GRADE
99' - 6"
AE601 3
AE301
2:12 ROOF SLOPE 2:12 ROOF SLOPE
AE301
CONCRETE PAD,
RE: CIVIL DRAWINGS
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
C
GRADE
99' - 6"
1 1/2" CORRUGATED METAL
PANEL OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
ZEE GIRT PER MANUFACTURERS
STANDARD
AE311
AE311
1' - 7"
1' - 8 3/8"
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
GRADE
99' - 6"
AE311
SIM
1 1/2" CORRUGATED METAL
PANEL OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
ZEE GIRT PER MANUFACTURERS
STANDARD
AE311
TYP
1' - 7 1/8"
1' - 8 5/8"
AE311
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:3
P
M
AE301
SECTIONS
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 3/8" = 1'-0"AE301
1 EW SECTION LOOKING NORTH
SCALE: 3/4" = 1'-0"AE301
2 TYPICAL WALL SECTION @ EAVE
SCALE: 3/4" = 1'-0"AE301
3 TYPICAL WALL SECTION @ GABLE
ADDENDUM 1 8/30/21
ROOF EAVE
115' - 10"
C
1 1/2" STANDING SEAM ROOF OVER VINYL
BAGGED BATT INSULATION TO MEET
SPECIFICATION
GUTTER HANGER
PER MANUFACTURERS STANDARD
PREFINISHED METAL GUTTER
EAVE CLOSURE
GUTTER APRON
EAVE STRUT
C PURLIN PER
MANUFACTURES
STANDARD
1 1/2" CORRUGATED METAL PANEL OVER
VINYL BAGGED BATT INSULATION TO
MEET SPECIFICATIONS
SNOW GUARD SYSTEM PER
MANUFACTURER'S STANDARD
LIGHTING PROTECTION SYSTEM, INSTALL PER
MANUFACTURER'S RECOMMENDATION - SEE
ELECTRICAL FOR MORE INFORMATION.
FLOOR
100' - 0"
C
GRADE
99' - 6"
1 1/2" RIGID INSULATION TURNED
DOWN TO FOOTING AND TURNED
BACK 2'-0" ENTIRE PERIMENTER
OF BUILDING
TYPICAL
2' - 0"
DRAINAGE MAT
1 1/2" CORRUGATED METAL
PANEL OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
6" CONCRETE ON
10 MIL VAPOR BARRIER ON
6" GRAVEL BASE
1/2" COMPRESSIBLE JOINT FILLER
CLOSER STRIP
Z GIRT PER MANUFACTURERS STANDARD
CM-1
BK-1
1' - 7" 5"
GRADING SLOPING AWAY FROM BUILDING -
REFER TO CIVIL DRAWINGS
5"
FLASHING
MORTAR NET
BRICK LEDGE
MASONRY TIE
16" O.C. HORIZONTALLY AND VERTICALLY
BRICK VENEER ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
FLASHING, COLOR TO MATCH METAL PANEL (CM-1)
B R
IC
K
V E
N E
E R
3'
C M
U B
A C
K U
P
2'
2' - 0"
P-1
7 5/8" 3" 1 3/4" 3 5/8"
8 3/8"
RAKE FLASHING - COLOR
TO MATCH ROOF (MR)
NAILING STRIP
STANDING SEAM
METAL ROOF (MR)
TREATED FASCIA
NAILER
PURLIN (BEYOND)
1 1/2" CORRUGATED METAL PANEL OVER
VINYL BAGGED BATT INSULATION TO
MEET SPECIFICATIONS
1 1/2" CORRUGATED METAL PANEL
CLOSER STRIP
M
IN6"
ALUMINUM DRIP EDGE
1 1/2" CORRUGATED METAL PANEL
OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONSVAPOR BARRIER TO
WRAP HEADER
METAL PANEL ATTACHED
TO STEEL ANGLE
CLOSER STRIP
END TRIM FLASHING -
COLOR TO MATCH (CM-1)
PREFINISHED WALL
LOUVER - COLOR TO
MATCH (CM-1)
ZEE GRIT FRAMMED
OPENING
V E
R
IF
Y S
IZ
E w / M
E C
H A
N
IC
A L
D R
A W
IN
G
S
CM-1
CM-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:3
P
M
AE311
SECTION DETAILS
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 1 1/2" = 1'-0"AE311
2 TYPICAL EAVE DETAIL
SCALE: 1 1/2" = 1'-0"AE311
1 TYPICAL BASE OF WALL DETAIL
SCALE: 3" = 1'-0"AE311
3 TYPICAL RAKE DETAIL
SCALE: 3" = 1'-0"AE311
4 WALL LOUVER DETAIL
ADDENDUM 1 8/30/21
S2
AS SCHEDULED 2" TYP
7'
CO
A S
S C
H E
D U
LE
D
AS SCHEDULED
DOOR AND FRAME TYPE LEGEND
DOOR TYPE ABBREVIATIONS
FL FLUSH
VL VISION LIGHT
NL NARROW LIGHT
HG HALF GLASS
FG FULL GLASS
GL GLASS
LL LOUVER
CO COILING DOOR
CS COILING SHUTTER
DOOR MATERIAL ABBREVIATIONS
AL ALUMINUM
HM HOLLOW METAL
WD WOOD
AS SCHEDULED
A S
S C
H E
D U
LE
D
FL
FRAME TYPE ABBREVIATIONS
S2 SINGLE / 2" HEAD
S4 SINGLE / 4" HEAD
R2 SINGLE, RESCUE / 2" HEAD
R4 SINGLE, RESCUE / 4" HEAD
L2 SINGLE w/SIDELITE / 2" HEAD L4 SINGLE w/SIDELITE / 4" HEAD ST SINGLE w/TRANSOM / 2" HEAD
D2 DOUBLE / 2" HEAD
D4 DOUBLE / 4" HEAD
E2 DOUBLE EGRESS / 2" HEAD
E4 DOUBLE EGRESS / 4" HEAD
W2 DOUBLE w/DIFFERENT WIDTH / 2" HEAD W4 DOUBLE w/DIFFERENT WIDTH / 4" HEAD DT DOUBLE w/TRANSOM / 2" HEAD
CU ICU SLIDING / HEAD SIZE VARY PER MFR.
BP BIPARTING / HEAD SIZE VARY PER MFR.
TS TELESCOPIC / HEAD SIZE VARY PER MFR.
FRAME MATERIAL ABBREVIATIONS
AL ALUMINUM
HM HOLLOW METAL
WD WOOD
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
1. PROVIDE WEATHERSTRIPPING.
2. PROVIDE HOLD OPENS.
3. REFER TO DETAILS INDICATED FOR HEAD, JAMB, AND SILL CONDITIONS.
VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION.
A. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL HARDWARE
REQUIREMENTS BETWEEN HARDWARE SUPPLIES, ACCESS CONTROL
VENDOR, AND ANY OTHER TRADES THAT ARE INVOLVED. REQUIRED POWER
SUPPLIES AND AUXILIARY COMPONENTS THAT IS REQUIRED TO MAKE A
HARDWARE SET WORK BETWEEN ACCESS CONTROL AND HARDWARE SHALL
BE PROVIDED.
B. ALL HOLLOW METAL DOORS AND FRAMES SHALL BE FACTORY PRIMED AND
RECEIVE PAINT FINISH ON SITE. REFER TO FINISH SCHEDULE FOR HOLLOW
METAL PAINT COLOR.
C. PROVIDE SEALANT AROUND PERIMETER OF DOOR/ WINDOW FRAME
ADJACENT TO WALL AND FLOOR CONSTRUCTION, BOTH SIDES.
D. LOCATE HINGE SIDE OF DOOR 6" OFF OF ADJACENT WALL UNLESS
OTHERWISE INDICATED ON FLOOR PLAN AS102.
E. MAINTAIN ADA CLEARANCE AROUND DOORS AND REFER ANY
DISCREPANCIES DUE TO COR AND ARCHITECT FOR CLARIFICATION.
F. RATED FRAMES, DOORS AND GLAZING SHALL BE UL LABELED IN A VISIBLE
LOCATION.
G. REFER TO DOOR/ WINDOW AND FRAME LEGEND FOR REFERENCE TO
TYPICAL HEAD, JAMB AND SILL DETAILS.
H. REFER TO SPECIFICATIONS AND ENGINEERING DRAWINGS FOR ADDITIONAL
HARDWARE INFORMATION.
I. COORDINATE POWER AND DATA REQUIREMENTS AT DESIGNATED DOOR
OPENINGS WITH ENGINEERING DRAWINGS.
DOOR AND FRAME GENERAL NOTES
DOOR SCHEDULE COMMENTS
WEATHERSTRIP SEAL
HOLLOW METAL DOOR
RE: DOOR SCHEDULE
ALUMINUM THRESHOLD
6"
CONCRETE PAD,
RE: CIVIL DRAWINGS
FOUNDATION WALL, RE:
STRUCTURAL DRAWINGS
HOLLOW METAL FRAME,
GROUTED SOLID.
RE: DOOR SCHEDULE
SEALANT, BOTH SIDES
ALUMINUM DRIP EDGE
1 1/2" CORRUGATED METAL PANEL
OVER VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
TRIPLE TREATED 2x6
FRAMED HEADER -
PAINTED (P-1)
VAPOR BARRIER TO
WRAP HEADER
METAL PANEL ATTACHED
TO STEEL ANGLE
CLOSER STRIP
WEATHERSTRIP
SILL
COIL DOOR CURTAIN
CONCRETE DRIVE,
RE: CIVIL DRAWINGS
FOUNDATION WALL,
RE: STRUCTURAL
DRAWINGS
FLOOR
100' - 0"
ROOF EAVE
115' - 10"
GRADE
99' - 6"
AE601
AE601
R .O
/2
STEEL ANGLE
FRAMMED HEADER
VAPOR BARRIER TO
WRAP HEADER
DOOR CURTAIN
CURTAIN TRACK
ATTACHED TO STEEL
ANGLE
COIL HOUSING
PAINT TO MATCH
METAL PANEL
SEALANT
ALUMINUM DRIP EDGE
1 1/2" CORRUGATED
METAL PANEL OVER
VINYL BAGGED BATT
INSULATION TO MEET
SPECIFICATIONS
METAL PANEL ATTACHED
TO STEEL ANGLE
COIL HOUSING AND MOTOR
ATTACHED TO STEEL COLUMN
(BEHIND)
CLOSER STRIP
STEEL COLUMN (BEHIND),
RE: STRUCTURAL DRAWINGS
1 1/2" CORRUGATED METAL PANEL
OVER VINYL BAGGED BATT
INSULATION TO MEET SPECIFICATIONS
VAPOR BARRIER
TO WRAP JAMB
STEEL COLUMN, REFER TO
STRUCTURAL DRAWINGS
CURTAIN TRACK ATTACHED
TO STEEL TUBE
COIL DOOR, RE: DOOR
SCHEDULE
ALUMINUM END TRIM
METAL PANEL ATTACHED
TO STEEL TUBE
ALUMINUM END TRIM
1 1/2" CORRUGATED METAL PANEL OVER
VINYL BAGGED BATT INSULATION TO
MEET SPECIFICATIONS
TRIPLE TREATED 2x6 FRAMED
JAMB - PAINTED (P-1)
HOLLOW METAL FRAME,
GROUTED SOLID
RE: DOOR SCHEDULE
SEALANT, BOTH SIDES
METAL PANEL ATTACHED
TO STEEL ANGLE
VAPOR BARRIER
TO WRAP JAMB
TREATED 2x10 WOOD CAP -
PAINTED (P-1) (BELOW)
MASONRY JAMB ANCHOR
SOLID BULL NOSE CMU AT
JAMBS - CUT AS REQUIRED
BRICK TURNED CORNER TO
MEET STEEL ANGLE
BRICK ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
VAPOR BARRIER
TO WRAP JAMB
SEALANT
HOLLOW METAL FRAME,
GROUTED SOLID
RE: DOOR SCHEDULE
BACKER ROD AND SEALANT
5/
8" 3"
1"
5/ 8"
WOOD BLOCKING
MASONRY JAMB ANCHOR
BRICK TURNED CORNER TO
MEET STEEL COLUMN
BACKER ROD AND SEALANT
5/
8" 3"
1"
5/ 8"
STEEL COLUMN, REFER TO
STRUCTURAL DRAWINGS
CURTAIN TRACK ATTACHED TO
STEEL COLUMN
BRICK ON
CAVITY ON
RIGID INSULATION ON
VAPOR BARRIER ON
CMU
VAPOR BARRIER
TO WRAP JAMB
COIL DOOR
RE: DOOR SCHEDULE
SOLID BULL NOSE CMU AT
JAMBS - CUT AS REQUIRED
BACKER ROD AND SEALANT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C
U s e rs \d c h ri s te n s e n \D o c u m e n ts \1
.5
.0
A v d c h ri s te n s e n M
N F
X
.r v t
/3
/2
:0
:3
P
M
AE601
DOOR SCHEDULE
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA CONSULTING ENGINEERS, INC.
10411 MEETING STREET
PROSPECT, KY 40059
CONSTRUCT CAMPUS WATER
SOFTENING PLANT
1900 E. MAIN ST., DANVILLE, IL
550-20-103
07/27/2020 AS DMC
BID DOCUMENTS
502.326.3085
SCALE: 1 1/2" = 1'-0"AE601
1 DOOR SILL DETAIL
SCALE: 3" = 1'-0"AE601
2 DOOR HEAD DETAIL, HM
SCALE: 1 1/2" = 1'-0"AE601
5 COIL DOOR SILL DETAIL
SCALE: 3/4" = 1'-0"AE601
9 WALL SECTION @ COIL DOOR
SCALE: 3" = 1'-0"AE601
8 COIL DOOR HEAD DETAIL
DOOR SCHEDULE
DOOR
NUMBER
ROOM DIMENSIONS DOOR FRAME DETAILS FIRE
RATING
GLAZING
TYPE
HARDWARE
SET COMMENTSNUMBER NAME WIDTH HEIGHT THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL
1 1 WATER SOFTENER PLANT 3' - 0" 7' - 0" 1 3/4" FL HM PAINT S2 HM PAINT 2/AE601 3/AE601 & 4/AE601 1/AE601 0 HW-1 1,2
G2 1 WATER SOFTENER PLANT 13' - 10" 12' - 6" 3" CD AL PAINT - - - 8/AE601 6/AE601 & 7/AE601 5/AE601
SCALE: 3" = 1'-0"AE601
7 COIL DOOR JAMB
SCALE: 3" = 1'-0"AE601
4 DOOR JAMB DETAIL, HM @ METAL PANEL
HW-2
SCALE: 3" = 1'-0"AE601
3 DOOR JAMB DETAIL, HM @ CMU
SCALE: 3" = 1'-0"AE601
6 COIL DOOR JAMB @ CMU
| Sheets |
| AE001 - ARCHITECTURAL SYMBOLS AND ABBREVIATIONS |
| AE101 - ARCHITECTURAL FLOOR PLAN & ROOF PLAN |
| AE201 - BUILDING ELEVATIONS |
| AE301 - SECTIONS |
| AE311 - SECTION DETAILS |
| AE601 - DOOR SCHEDULE |