36C25218B1083-A00002003.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25218B1083
About this file
36C25218B1083 A00002 S06 - A00002 - Att - Addendum 1 - A100.5.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25219C0031-000.docx | DOCX document | |
| 36C25218B1083-A00003001.pdf | ||
| 36C25218B1083-A00003000.docx | DOCX document | |
| 36C25218B1083-A00002004.pdf | ||
| 36C25218B1083-A00002001.docx | DOCX document | |
| 36C25218B1083-A00002002.pdf | ||
| 36C25218B1083-A00002005.pdf | ||
| 36C25218B1083-A00002007.pdf | ||
| 36C25218B1083-A00002008.docx | DOCX document | |
| 36C25218B1083-A00002000.docx | DOCX document | |
| 36C25218B1083-A00002006.pdf | ||
| 36C25218B1083-A00001000.docx | DOCX document | |
| 36C25218B1083-A00001001.pdf | ||
| 36C25218B1083-003.pdf | ||
| 36C25218B1083-001.docx | DOCX document | |
| 36C25218B1083-005.pdf | ||
| 36C25218B1083-002.pdf | ||
| 36C25218B1083-004.pdf | ||
| 36C25218B1083-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
install new piping. Notch rigid insulation on exterior wall minimum amount required to install piping. Replace
At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet
T
T
T
T
T
T
T
T
DPM
DPM
T
PACS
WORKSTATION
RECEPTION
WAITING
AREA
SUB
WAIT
HALLWAY
2262P
PATIENT
CHANGING
RADIOLOGY
RADIOLOGY
CONTROL
ROOM
2263A
PATIENT
TOILET
FEMALE
TOILET
MALE
TOILET
CORRIDOR
C2-2
STORAGE
ROOM
2263B
CONTROL
ROOM
2261A
PACS
COMPUTER
2215A
CORRIDOR
C2-3
2 2
1. Remove existing convector cover and infill opening to fit new convector per detail 1/A100.
2. Remove existing gypsum board below window stool and on adjacent wall as required to install new piping.
Notch rigid insulation on exterior wall minimum amount required to install piping. Replace with 5/8" gypsum board attached to existing framing or furring. Provide PNT-1 finish to match existing paint.
3. Remove existing gypsum board and rigid insulation below window stool and on adjacent wall as required to install new piping. Notch rigid insulation on exterior wall minimum amount required to install piping. Replace with 5/8" gypsum board attached to existing framing or furring. Provide PNT-2 finish to match existing paint.
4. Remove and reinstall existing casework and countertop as required to install new convector.
5. Remove existing gypsum board, ceramic tile and tile backer board below window stool and on adjacent wall as required to install new piping. Notch rigid insulation on exterior wall minimum amount required to install piping. Replace with 5/8" gypsum board or tile backer board and tile to match existing, attached to existing framing or furring. Provide PNT-1 finish to match existing paint, WT-1/WT-2 to match existing 48" high tile wainscot.
1. Second floor project area is a Healthcare occupancy per NFPA 101 - 2015.
2. Light lines indicate existing work to remain, dark lines indicate new work.
3. Field verify all dimensions and clearances before beginning construction.
4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.
5. Patch all abandoned holes in floors with concrete to match existing construction.
6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.
7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.
Keynotes
General Notes
SCALE:
Second Floor Plan
1/4" = 1'-0"
N
MEP PROJECT NO.: G29.17.04
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date: Dwg. of
420 RAIL STREET
NEGAUNEE, MI 49866
PHONE: 906-475-6616
NDW PROJECT NUMBER: 1722
SECOND FLOOR PLAN -
PART B
4 24
ADDENDUM 1 10/30/2018
AutoCAD SHX Text
DUCT THRU FLOOR
AutoCAD SHX Text
STAIR 2
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
STAIR 4
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
MECH. SHAFT
AutoCAD SHX Text
PASSENGER ELEVATOR
AutoCAD SHX Text
MECH. SHAFT
AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL
AutoCAD SHX Text
SMOKE/ FIRE/ RATED PARTITION TYPES
AutoCAD SHX Text
INSTALL PERIMETER HEAT IN
AutoCAD SHX Text
IMAGING AND 4 EAST
AutoCAD SHX Text 585-17-105
AutoCAD SHX Text No. 1
AutoCAD SHX Text
IRON MOUNTAIN, MICHIGAN
AutoCAD SHX Text
OCTOBER 30, 2018
AutoCAD SHX Text
RU
AutoCAD SHX Text
RU
AutoCAD SHX Text A100.5
| Sheets and Views |
| A100.5 |
File details come from the government source that posted it.