About this file

36C25218B1083 S02 - Att - Plans - Architect - 6.22.18.pdf

View the file

Other files

File Type Posted
36C25219C0031-000.docx DOCX document
36C25218B1083-A00003001.pdf PDF
36C25218B1083-A00003000.docx DOCX document
36C25218B1083-A00002004.pdf PDF
36C25218B1083-A00002001.docx DOCX document
36C25218B1083-A00002002.pdf PDF
36C25218B1083-A00002005.pdf PDF
36C25218B1083-A00002007.pdf PDF
36C25218B1083-A00002008.docx DOCX document
36C25218B1083-A00002000.docx DOCX document
36C25218B1083-A00002006.pdf PDF
36C25218B1083-A00002003.pdf PDF
36C25218B1083-A00001000.docx DOCX document
36C25218B1083-A00001001.pdf PDF
36C25218B1083-001.docx DOCX document
36C25218B1083-005.pdf PDF
36C25218B1083-002.pdf PDF
36C25218B1083-004.pdf PDF
36C25218B1083-000.docx DOCX document
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. Not Used.

1. Fourth floor project area is a Healthcare occupancy per NFPA 101 - 2015.

2. Light lines indicate existing work to remain, dark lines indicate new work.

3. Field verify all dimensions and clearances before beginning construction.

4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.

5. Patch all abandoned holes in floors with concrete to match existing construction.

6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.

7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.

8. Corridor work outside of enclosed (limited access) work zones shall be at night, between the hours of 4:30 PM and 10:00 PM.

9. Refer to 01 00 00 General Conditions, Section 1.6H for specific phase requirements and milestones.

PA

RT

A

PA

RT

A

PA

RT

B

PART B

PA

RT

C

PART C

PHASE 2 - THESE SPACES WILL BE AVAILABLE FOR CONSTRUCTION AT THE

COMPLETION OF PHASE 1.

PHASE 4 - THESE SPACES WILL BE AVAILABLE FOR CONSTRUCTION AT THE

COMPLETION OF PHASE 3.

PHASE 3 - THESE SPACES WILL BE AVAILABLE FOR CONSTRUCTION AT THE

COMPLETION OF PHASE 2.

PHASE 1 - THESE SPACES WILL BE AVAILABLE FOR CONSTRUCTION AT THE

COMPLETION OF PHASE 0.

PHASE 0 - WILL COMMENCE WITH THE ISSUANCE OF THE NOTICE TO PROCEED

AND SHALL CONSIST OF SCHEDULE PREPARATION AND APPROVAL.

PHASE 5 - THESE SPACES WILL BE AVAILABLE FOR CONSTRUCTION AT THE

COMPLETION OF PHASE 4.

PHASING NOTE

A MAXIMUM OF FOUR ROOMS MAY

BE OUT OF USE AT ANY TIME.

PERIMETER HEAT DOES NOT NEED

TO BE OPERATIONAL BUT ALL

PRESSURE TESTING, FINISHES AND

CLEANING NEED TO BE COMPLETED

BEFORE TURNING ROOMS BACK TO

OWNER.

Keynotes

General Notes

SCALE:

Fourth Floor Phasing Plan

1/8" = 1'-0"

N

MEP PROJECT NO.: G29.17.04

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date: Dwg. of

420 RAIL STREET

NEGAUNEE, MI 49866

PHONE: 906-475-6616

NDW PROJECT NUMBER: 1722

FOURTH FLOOR PHASING

PLAN

2 23

100% REVIEW 1/30/2018

Key Plan

BID SET 6/18/2018

AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL

AutoCAD SHX Text

SMOKE/ FIRE/ RATED PARTITION TYPES

AutoCAD SHX Text

DUMB WAITER

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text

SERVICE ELEVATOR

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

FIRE EQUIP

AutoCAD SHX Text

STAIR 3

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

LDRY CHUT

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

FIRE EQUIP

AutoCAD SHX Text

DN

AutoCAD SHX Text

STAIR 4

AutoCAD SHX Text

UP

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text

INSTALL PERIMETER HEAT IN

AutoCAD SHX Text

IMAGING AND 4 EAST

AutoCAD SHX Text 585-17-105

AutoCAD SHX Text No. 1

AutoCAD SHX Text

IRON MOUNTAIN, MICHIGAN

AutoCAD SHX Text June 18, 2018

AutoCAD SHX Text

RU

AutoCAD SHX Text

RU

AutoCAD SHX Text A001

1. Remove existing convector cover and infill opening to fit new convector per detail 1/A100.

2. Remove existing gypsum board below window stool and on adjacent wall as required to install new piping.

Notch rigid insulation on exterior wall minimum amount required to install piping. Replace with 5/8" gypsum board attached to existing framing or furring. Provide PNT-1 finish to match existing paint.

3. Remove existing gypsum board and rigid insulation below window stool and on adjacent wall as required to install new piping. Notch rigid insulation on exterior wall minimum amount required to install piping. Replace with 5/8" gypsum board attached to existing framing or furring. Provide PNT-2 finish to match existing paint.

4. Remove and reinstall existing casework and countertop as required to install new convector.

1. Second floor project area is a Healthcare occupancy per NFPA 101 - 2015.

2. Light lines indicate existing work to remain, dark lines indicate new work.

3. Field verify all dimensions and clearances before beginning construction.

4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.

5. Patch all abandoned holes in floors with concrete to match existing construction.

6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.

7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

1 1

2 5/8"

2" XPS INSULATION

NEW CONVECTOR

2" FOIL FACED

POLYISOCYANURATE

INSULATION ENTIRE

HEIGHT OF CAVITY

EXISTING WALL

CONSTRUCTION

16 GA. 2" COLD ROLLED

CHANNEL

"J" BEAD

5/8" GYPSUM BOARD 3 5/8" METAL STUD

FRAMING SIZED TO

MATCH NEW

CONVECTOR ROUGH

OPENING

EXISTING STEEL BOX

6"

5/8" GYPSUM BOARD

6" METAL STUD

FRAMING SIZED TO

FIT CONVECTOR

ROUGH OPENING

"J" BEAD

EXISTING WALL FURRING

AND GYPSUM BOARD

PACS

VIEWING

CLEAN

SUPPLY

STERILE

CLEAN SUPPLY

ULTRASOUND

PATIENT

TOILET

ULTRASOUND

SUPERVISOR

RADIOLOGY

FLUOROSCOPY

STAFF LOUNGE

LOCKERS

PATIENT

TOILET

2242B

EQUIP

ALCOVE

2230B

HALLWAY

2230P

STRESS

TEST

PACS

VIEWING

TECH WORK

ROOM

UNISEX

TOILET

LAUNDRY

CHUTE

SOILED

HOLDING

2251 CT SCAN

CONTROL

CT SCAN

HALLWAY

2240P

CONTROL

ROOM

2242ASTAFF

CHANGING

2245A

22 2 2

Keynotes

General Notes

SCALE:

Second Floor Plan

1/4" = 1'-0"

N

MEP PROJECT NO.: G29.17.04

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date: Dwg. of

420 RAIL STREET

NEGAUNEE, MI 49866

PHONE: 906-475-6616

NDW PROJECT NUMBER: 1722

SECOND FLOOR PLAN -

PART A

3 23

50% REVIEW 12/6/2017

SCALE:

Convector Detail

3" = 1'-0"

A100

Key Plan

100% REVIEW 1/30/2018

BID SET 6/18/2018

AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL

AutoCAD SHX Text

SMOKE/ FIRE/ RATED PARTITION TYPES

AutoCAD SHX Text

STAIR 3

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

MECH CHASE

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

C_TOILETS

AutoCAD SHX Text

KINGSTON

AutoCAD SHX Text K-4330

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

C_TOILETS

AutoCAD SHX Text

KINGSTON

AutoCAD SHX Text K-4330

AutoCAD SHX Text

INSTALL PERIMETER HEAT IN

AutoCAD SHX Text

IMAGING AND 4 EAST

AutoCAD SHX Text 585-17-105

AutoCAD SHX Text No. 1

AutoCAD SHX Text

IRON MOUNTAIN, MICHIGAN

AutoCAD SHX Text

JUNE 18, 2018

AutoCAD SHX Text

RU

AutoCAD SHX Text

RU

A100

1. Remove vinyl wall covering and vinyl wall base from exterior wall. Repair drywall indicated to remain to receive new paint finish.

2. Cut existing gypsum board as required to install new piping. Patch with 5/8" gypsum board to match existing.

3. Remove existing gypsum board, insulation and studs at former convector opening. Frame opening for new convector per detail 1/A101. Provide furring, insulation and new gypsum board on exterior wall with new piping concealed within furring. Cut existing floor back to new wall face. Remove existing plastic laminate window stool and provide new per detail 2/A101.

4. Provide PNT-3 finish and vinyl wall base at modified walls.

5. Extend existing wall with 3 5/8" light gage framing and 5/8" drywall to conceal new pipes.

6. Radiant ceiling panel in existing acoustical tile ceiling.

7. Stop wall furring clear of existing casework door swing. Step back new window stool edge 2 5/8" at end of wall furring.

8. Remove gypsum board from infill framing to soffit above for routing pipes down to convector. Replace with

5/8" gypsum board and finish to match existing surface. Remove gypsum board at new convector location and modify lightgage infill framing to create opening for new convector. Repair gypsum board to match existing wall.

9. Remove and reinstall existing corner guard and wall mounted computer cabinet.

10.Remove and reinstall existing wall mounted computer cabinet.

11.Remove and reinstall casework and countertop as required to install new convector. Modify countertop to fit furred out wall.

1. Fourth floor project area is a Healthcare occupancy per NFPA 101 - 2015.

2. Light lines indicate existing work to remain, dark lines indicate new work.

3. Field verify all dimensions and clearances before beginning construction.

4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.

5. Patch all abandoned holes in floors with concrete to match existing construction.

6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.

7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.

MENS

TOILET

TOILET

FAMILY

BREAK AREA

4107A

MED / SURG (4E)

WAITING ROOM

ISOLATION

ROOM

PATIENT

TOILET

4205A

ANTE

ROOM

SEMI-PRIVATE

OBSERVATION

TOILET

4211A

TOILET

4211A

MED / SURG

#2

CORRIDOR

4212C

MED / SURG

#3

TOILET

4216A

EQUIPMENT

DRESSING

ROOM

4282A

LOCKER

MOD

EDUCATION /

CHART ROOM

POLYSOMNOGRAPHER

PULMONARY

FUNCTION

PASSAGE

4280P

TOILET

STERILE

SUPPLY

HSKPG

CLOSET

BLOOD

GAS

CARDIO-P

WAITING

ELEVATOR

LOBBY

PA

RT

A

PA

RT

C

PA

RT

A

PA

RT

B

PART B

PART C

3 3

2 5/8"

2" XPS INSULATION w/

Z FURRING AT 24" O.C.

NEW CONVECTOR

2" FOIL FACED

POLYISOCYANURATE

INSULATION ENTIRE

HEIGHT OF CAVITY

EXISTING WALL

CONSTRUCTION

16 GA. 2" COLD ROLLED

CHANNEL

"J" BEAD

5/8" GYPSUM BOARD 3 5/8" METAL STUD

FRAMING SIZED TO

MATCH NEW

CONVECTOR ROUGH

OPENING

EXISTING STEEL BOX

6"

5/8" GYPSUM BOARD

6" METAL STUD

FRAMING SIZED TO

FIT CONVECTOR

ROUGH OPENING

"J" BEAD

2"

2" XPS w/ Z FURRING

5/8" GYPSUM BOARD

258"

PLASTIC LAMINATE STOOL

SEALANT AND BACKER ROD

EXISTING STRUCTURAL CLAY

TILE AND PLASTER WALL

ALUMINUM WINDOW

FIELD VERIFY

4 4

3 4

3 4 4 3

4 3

15454 3 4 7

34 7 34

Keynotes

General Notes

SCALE:

Fourth Floor Plan Part A

1/4" = 1'-0"

N

MEP PROJECT NO.: G29.17.04

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date: Dwg. of

420 RAIL STREET

NEGAUNEE, MI 49866

PHONE: 906-475-6616

NDW PROJECT NUMBER: 1722

FOURTH FLOOR PLAN -

PART A

4 23

50% REVIEW 12/6/2017

SCALE:

Convector Detail

3" = 1'-0"

A101

SCALE:

Window Stool Detail

1 1/2" = 1'-0"

A101

PHASING NOTE:

REFER TO A001 - FOURTH

FLOOR PHASING PLAN FOR

ALL PROJECT PHASING.

Key Plan

100% REVIEW 1/30/2018

BID SET 6/18/2018

AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL

AutoCAD SHX Text

SMOKE/ FIRE/ RATED PARTITION TYPES

AutoCAD SHX Text

DUMB WAITER

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text

SERVICE ELEVATOR

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

FIRE EQUIP

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

INSTALL PERIMETER HEAT IN

AutoCAD SHX Text

IMAGING AND 4 EAST

AutoCAD SHX Text 585-17-105

AutoCAD SHX Text No. 1

AutoCAD SHX Text

IRON MOUNTAIN, MICHIGAN

AutoCAD SHX Text

JUNE 18, 2018

AutoCAD SHX Text

RU

AutoCAD SHX Text

RU

A101

5/8" gypsum board and finish to match existing surface. Remove gypsum board at new convector location and

At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet

SEMI-PRIVATE

OBSERVATION

TOILET

4211A

MED / SURG #2

PHYS CHART

OFFICE

SOCIAL

WORKER

STAFF

TOILET

CLEAN

LINEN

NURSE

MANAGER

TUB

ROOM

BARIATRIC

M/S #4

TOILET

4233A

TOILET

4237A

BARIATRIC

M/S #5

NURSE

STATION

MED / SURG

#6

TOILET

4236A

TOILET

4234A

MED / SURG

#7

TOILET

4230A

MED / SURG

#8

CLEAN

LINEN

STORAGE

SOILED

LAUNDRY

CORRIDOR

4212C

TOILET

4215A

MED / SURG

#9

TOILET

4245A TOILET

4251A

MED / SURG

#10

PASSAGE

4242P NURSE

STATION

PA

RT

A

PA

RT

B

PART B

PART C

3 4

3 42

3 4

3 4

1. Remove vinyl wall covering and vinyl wall base from exterior wall. Repair drywall indicated to remain to receive new paint finish.

2. Cut existing gypsum board as required to install new piping. Patch with 5/8" gypsum board to match existing.

3. Remove existing gypsum board, insulation and studs at former convector opening. Frame opening for new convector per detail 1/A101. Provide furring, insulation and new gypsum board on exterior wall with new piping concealed within furring. Cut existing floor back to new wall face. Remove existing plastic laminate window stool and provide new per detail 2/A101.

4. Provide PNT-3 finish and vinyl wall base at modified walls.

5. Extend existing wall with 3 5/8" light gage framing and 5/8" drywall to conceal new pipes.

6. Radiant ceiling panel in existing acoustical tile ceiling.

7. Stop wall furring clear of existing casework door swing. Step back new window stool edge 2 5/8" at end of wall furring.

8. Remove gypsum board from infill framing to soffit above for routing pipes down to convector. Replace with

5/8" gypsum board and finish to match existing surface. Remove gypsum board at new convector location and modify lightgage infill framing to create opening for new convector. Repair gypsum board to match existing wall.

9. Remove and reinstall existing corner guard and wall mounted computer cabinet.

10.Remove and reinstall existing wall mounted computer cabinet.

11.Remove and reinstall casework and countertop as required to install new convector. Modify countertop to fit furred out wall.

1. Fourth floor project area is a Healthcare occupancy per NFPA 101 - 2015.

2. Light lines indicate existing work to remain, dark lines indicate new work.

3. Field verify all dimensions and clearances before beginning construction.

4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.

5. Patch all abandoned holes in floors with concrete to match existing construction.

6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.

7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.

Keynotes

General Notes

SCALE:

Fourth Floor Plan Part B

1/4" = 1'-0"

N

MEP PROJECT NO.: G29.17.04

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date: Dwg. of

420 RAIL STREET

NEGAUNEE, MI 49866

PHONE: 906-475-6616

NDW PROJECT NUMBER: 1722

FOURTH FLOOR PLAN -

PART B

5 23

50% REVIEW 12/6/2017

PHASING NOTE:

REFER TO A001 - FOURTH

FLOOR PHASING PLAN FOR

ALL PROJECT PHASING.

Key Plan

100% REVIEW 1/30/2018

BID SET 6/18/2018

AutoCAD SHX Text

DUMB WAITER

AutoCAD SHX Text

STAIR 3

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

LDRY CHUT

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

FIRE EQUIP

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL

AutoCAD SHX Text

SMOKE/ FIRE/ RATED PARTITION TYPES

AutoCAD SHX Text

INSTALL PERIMETER HEAT IN

AutoCAD SHX Text

IMAGING AND 4 EAST

AutoCAD SHX Text 585-17-105

AutoCAD SHX Text No. 1

AutoCAD SHX Text

IRON MOUNTAIN, MICHIGAN

AutoCAD SHX Text

JUNE 18, 2018

AutoCAD SHX Text

RU

AutoCAD SHX Text

RU

A102

EQUIPMENT

CORRIDOR

4212C

NURSE

STATION

TOILET

4216A

MED / SURG

#3

DATA

PHONE

NOURISH

COMMUNICATOR

MEDS

MED / SURG

BED

MED / SURG

BED

ANTEROOM

4271A

SUPPLY

MED / SURG

BED

TRAINING

ROOM

CART

CLOSET

SUPPLY

NURSE

STATION

MED / SURG

BED

TOILET

4270A

TOILET

4268A

MED / SURG

BED

CORRIDOR

4260C

NURSE

STATION

CART

ALCOVE

MED / SURG

BED

CONSULT

ROOM

HOUSEKEEPING

TOILET

4262A

EQUIP.

STORAGE

MED / SURG

#11

TOILET

4250A

NURSE

STATION

PASSAGE

4242P

ELEVATOR

LOBBY

PA

RT

A

PA

RT

C

PART B

PART C

3 4

1. Remove vinyl wall covering and vinyl wall base from exterior wall. Repair drywall indicated to remain to receive new paint finish.

2. Cut existing gypsum board as required to install new piping. Patch with 5/8" gypsum board to match existing.

3. Remove existing gypsum board, insulation and studs at former convector opening. Frame opening for new convector per detail 1/A101. Provide furring, insulation and new gypsum board on exterior wall with new piping concealed within furring. Cut existing floor back to new wall face. Remove existing plastic laminate window stool and provide new per detail 2/A101.

4. Provide PNT-3 finish and vinyl wall base at modified walls.

5. Extend existing wall with 3 5/8" light gage framing and 5/8" drywall to conceal new pipes.

6. Radiant ceiling panel in existing acoustical tile ceiling.

7. Stop wall furring clear of existing casework door swing. Step back new window stool edge 2 5/8" at end of wall furring.

8. Remove gypsum board from infill framing to soffit above for routing pipes down to convector. Replace with

5/8" gypsum board and finish to match existing surface. Remove gypsum board at new convector location and modify lightgage infill framing to create opening for new convector. Repair gypsum board to match existing wall.

9. Remove and reinstall existing corner guard and wall mounted computer cabinet.

10.Remove and reinstall existing wall mounted computer cabinet.

11.Remove and reinstall casework and countertop as required to install new convector. Modify countertop to fit furred out wall.

1. Fourth floor project area is a Healthcare occupancy per NFPA 101 - 2015.

2. Light lines indicate existing work to remain, dark lines indicate new work.

3. Field verify all dimensions and clearances before beginning construction.

4. Floor structure is Two-Hour Rated Concrete Construction. Maintain fire rating and provide firestopping at all penetrations.

5. Patch all abandoned holes in floors with concrete to match existing construction.

6. At all removed piping and conduit fill all holes in partitions indicated to be fire rated with firestopping to meet or exceed wall rating. Fill all holes in smoke resistive walls or full height partitions to seal opening.

7. Remove and reinstall ceiling tile as required to install new piping. Replace any damaged ceiling tile to match existing.

Keynotes

General Notes

SCALE:

Fourth Floor Plan Part C

1/4" = 1'-0"

N

MEP PROJECT NO.: G29.17.04

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date: Dwg. of

420 RAIL STREET

NEGAUNEE, MI 49866

PHONE: 906-475-6616

NDW PROJECT NUMBER: 1722

FOURTH FLOOR PLAN -

PART C

6 23

50% REVIEW 12/6/2017

PHASING NOTE:

REFER TO A001 - FOURTH

FLOOR PHASING PLAN FOR

ALL PROJECT PHASING.

Key Plan

100% REVIEW 1/30/2018

BID SET 6/18/2018

AutoCAD SHX Text

DUMB WAITER

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

DN

AutoCAD SHX Text

STAIR 4

AutoCAD SHX Text

UP

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

MECH SHAFT

AutoCAD SHX Text

PASSENGER ELEVATOR

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text SMOKE RESISTIVE WALL SMOKE BARRIER WITH ONE HOUR FIRE RATING ONE HOUR FIRE RATED WALL TWO HOUR FIRE WALL

AutoCAD SHX Text

SMOKE/ FIRE/ RATED PARTITION TYPES

AutoCAD SHX Text

INSTALL PERIMETER HEAT IN

AutoCAD SHX Text

IMAGING AND 4 EAST

AutoCAD SHX Text 585-17-105

AutoCAD SHX Text No. 1

AutoCAD SHX Text

IRON MOUNTAIN, MICHIGAN

AutoCAD SHX Text

JUNE 18, 2018

AutoCAD SHX Text

RU

AutoCAD SHX Text

RU

A103