Item # _____________________________________

Quantity ___________________________________

C.S.I. Section 11400

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 1 of 12

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER

FLIGHT-TYPE DISHWASHER701 S Ridge Avenue, Troy, OH 45374 1-888-4HOBART • www.hobartcorp.com

FT

1000 E

N E

R G

Y R

E C

O V

E R

Y W

IT

H

B

LO

W E

R D

R Y

E R

FLIG

H

T -T

Y P

E D

IS

H

W A

S H

E R

STANDARD FEATURES

■ Pumped rinse system (pressure gauge not required)

■ Water usage 58 gph

■ Digital controls with machine diagnostics

■ Low temperature alert

■ Single point vent location

■ 31" access on prewash, power wash and power rinse chambers; 20" access on dual rinse and ASR chambers

■ Start and stop switches at both ends

■ Doors open indicator

■ Drains open indicator

■ Door interlocks

■ 31⁄2 H.P. prewash, 5 H.P. power wash and power rinse pump motors, all TEFC

■ Capless Auto Clean wash arms

■ Easy to remove stainless steel scrap pans and baskets

■ 30" wide conveyor belt

■ Dual Rinse

■ Automatic Soil Removal system (ASR)

■ Auto Clean

■ Auto Delime

■ Energy Recovery

■ Front and rear panels

■ Variable speed conveyor

DIRECTION OF OPERATION

❑ Right to Left

❑ Left to Right

VOLTAGE

❑ 208/60/3

❑ 240/60/3

❑ 480/60/3

❑ Other voltages available – consult factory

MODEL

❑ FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

OPTIONS AT EXTRA COST

❑ Electric Tank Heat

❑ Steam Tank Heat

❑ Booster Heater

❑ Electric
❑ Steam

❑ Blower Dryer

❑ Electric
❑ Steam

❑ 6" higher than standard chamber

❑ Multiple conveyor choices

❑ Circuit breakers

❑ Security package

❑ Other options available, consult factory

ACCESSORIES

❑ Flanged feet

❑ Water hammer arrestor/PRV (installed by others)

❑ Drain water tempering kit (installed by others)

❑ Vent connection kit

Specifications, Details and Dimensions on Inside and Back.

• LA Research Report M660004

• Complies with EPA Reduction of Lead in Drinking

Water Act 2014

• Meets requirements of ASSE Standard No. 1004

Hobart FT1000‐DRYYES Item #1

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 1

701 S Ridge Avenue, Troy, OH 45374 1-888-4HOBART • www.hobartcorp.com

Page 2 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

DESIGN: Fully automatic, flight-type dish machine consisting of a load section with Automatic Soil Removal system, power recirculating prewash, power wash, power rinse and dual rinse/final rinse section.

Included with each machine will be flexible plastic strip curtains to control overspray.

CONSTRUCTION: Stainless steel tank and chambers with No. 3 polish on appearance surfaces. Frame, legs and feet to be constructed of stainless steel.

Inspection doors to be chamber width.

PUMPS: Recirculating stainless steel pumps with stainless steel impellers. Pump housing has easy to remove coverplate for access to impeller. Wash pumps are self-draining.

MOTORS: Totally enclosed fan cooled (TEFC) design with overload protection. Pump motors to be 31⁄2 H.P. for prewash, 5 H.P. for power wash and power rinse, and conveyor motor to be 1⁄3 H.P. Available in electrical specifications of 208/60/3, 240/60/3 and 480/60/3.

CONTROLS: A stainless steel control center with electronic digital controls mounted at eye level.

Power “On/Off” and “Start/Stop” switches integrated into keypad. Digital display indicates door(s) open, low temperature alert, tanks/final rinse temperatures, Auto Clean and Auto Delime instructions and notifica-tions, and other pertinent operating data. Additional “Start/Stop” switches are located at each end of machine. Conveyor speed button included on the control center to provide for the adjustable speed conveyor.

FLIGHT-TYPE CONVEYOR: Stainless steel side links, tie rods and conveyor tracks. Injection molded, resilient Duraflex flight links.

VENT: Indirect vent connection with integral powered fan.

AUTOMATIC SOIL REMOVAL SYSTEM (ASR):

Two foot section with specialized soil removal wash arms which removes food soil from the ware before it reaches the prewash tank. System will pump food soil from the ASR tank into an external collector located under the load section, minimizing the need to pre-scrap dishes and reducing detergent consump-tion. Operator can easily remove and clean external collector without interruption of machine operation.

RECIRCULATING PREWASH SECTION: Prewash compartment is fitted with upper and lower wash arms. Large removable one piece perforated stainless steel screen sloped downward to deep stainless steel scrap basket.

TANK HEAT: Power wash, power rinse and dual rinse tank water temperatures are thermostatically controlled. Low water protection is provided. Specify either electric or steam heat.

FINAL RINSE: Easily removed final rinse arms.

ENERGY RECOVERY: Energy Recovery system operates with a cold water line, capturing energy from exhaust air, and using it to elevate the temperature of the water entering the booster heater. The result is savings – both in hot water and in energy.

CONVEYOR DRIVE UNIT: Powered by a 1⁄3 H.P.

motor. Trip mechanism provided on unload section.

Jam protection is provided by load sensing switch at drive platform. Conveyor speed adjustment of 4.0 feet per minute to 8.5 feet per minute is provided on the digital display keypad.

DRAINS: Manual, hand-operated, located at each tank. One manual and automatic master drain to be used for Auto Clean and Auto Delime.

BLOWER DRYER: Includes (2) 2 H.P. fan motors with sealed ball bearings and overload protection.

Available in electric or steam heat.

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER

FLIGHT-TYPE DISHWASHER

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 2

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 3 of 12

No other control system allows easier monitoring.

The digital controls are placed in a convenient panel that lets operators verify proper operation and temperatures at a glance. Digital display indicates the unit is on, and confirms that the doors are closed. Automatic door interlocks prevent the pump and conveyor from operating if the doors are open.

Easy-to-read digital display indicates accurate tem-peratures of the 150°F wash, 160°F power rinse, 160°F dual rinse and 180°F final rinse — critical for proper HACCP system record-keeping.

Stainless steel pump is built for long life.

The stainless steel pump housing and impeller offer greater durability and long life. The pump motor is totally enclosed and fan cooled (TEFC) to protect it from water spray during dishroom clean-up.

Scrap baskets capture food particles and are easy to clean.

The sloped screens that carry scraps to the scrap baskets are steeper, so less soil gets into the tanks. The basket opening is larger for easy cleaning and basket handles have been designed for easy lift-out access.

The load section also features a removable scrap basket which contains soil that is pumped from the ASR section. All scrap baskets and strainers are stainless steel for strength and durability.

The FT1000 Series saves water and energy.

The unit has the lowest water and energy consumption in the industry, yet provides effective cleaning and sanitizing that meets NSF International requirements.

This is achieved through a carefully balanced ratio of water flow to pressure.

Insulated doors and thermal layered curtains also reduce heat loss. The unit’s 58 gallons per hour rinse flow rate saves both water and the energy to heat it.

Variable speed conveyor offers increased throughput.

The conveyor on the FT1000 Series is wider so it can handle more ware.

Result: more volume and versatility, quicker work. Its speed is easily adjustable for the type of ware, soiled condition, or workforce requirements. It runs at 4.0 -

8.5 feet per minute.

Energy Recovery system reclaims heat for energy.

The Energy Recovery system’s heat exchanger captures escaping heat and steam from the exhaust air in the dish machine, and uses it to preheat the incoming cold water supply to 120°F before it enters the booster heater.

In addition to energy savings, the Energy Recovery system provides a viable use for this otherwise exhausted heat.

Self-draining wash pumps help keep water clean.

Pumps are self-draining when the machine is shut down, so there is no residual water left in the pumps.

Installation is quick and easy with modular design, minimal wiring connections, and single point vent.

Modular design means the FT1000 installs quickly and reliably. The control panel is already in place, premounted to the dual rinse/final rinse section.

Wiring connections are minimal, and there is only a single vent, saving time and expense. The control box uses a “single plane” circuitry design for easy accessibility during installation and service.

The FT1000 is ready to run quickly.

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER

FLIGHT-TYPE DISHWASHER

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 3

Page 4 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

22" HIGH X 29-13/16"

WIDE OPENING WILL

HANDLE 18" X 26" BUN PANS

NOTE: CLEARANCE FROM WALL

24" RECOMMENDED, 6" MINIMUM

WITH DETERGENT DISPENSER

ON THE TOP

44 13/16" SEE NOTE (a)

FLOOR LINE

35"

NOTE: STRAINER PANS

REQUIRE 35" TO

BE REMOVED. EXTRA

CLEARANCE SHOULD BE

PROVIDED.

40 3/8"

NOTE: REFER TO LATEST

EDITION OF NATIONAL

ELECTRICAL CODE AND

LOCAL BUILDING CODES

FOR PROPER CLEARANCE

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

ELECTRIC L-R

P2

V1

P3

V1

E1

E2

E3

E4

P1

P1 P2

P3

E1E2E3

P3

E6E7E8E9

E4E5

E9

E8

E7

E6

E5

18 3/4"

37 1/2"

55 11/16"

63 3/8"

11 13/16"

9 15/16"

23 3/4"

60" 52"

44 9/16"

160 1/16"

DIRECTION OF OPERATION

ASR

BLOWER/

DRYER

6"

36 1/2"

62 3/4"

36 1/4"

3"

35 7/16" 35 7/16" 35 7/16" 25 9/16"

5 3/4"

23 3/4"

6" AIR

GAP

FLOOR LINE

7 3/16"3 15/16"

UNLOAD "C"

OVER FRAME "A"

43 5/16"

25 9/16"

LOAD "B" 8' 7/16"

81 7/8"

V1

EXHAUST HOOD

SUPPLIED BY

OTHERS

POWER

WASH

PRE-

WASH

POWER

RINSE

AUX

RNS

FNL

RNS

UNLOAD

END

LOAD

END

89 3/8" SEE NOTE (e)

MODEL NO. "A" "B" "C"

NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"

7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4"

11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"

23' 3-1/2" 24' 3-1/4" 25' 3-3/32" 24' 11-1/4" 25' 11" 26' 10-27/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 31' 5-15/16" 32' 5-25/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32"

7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"

FT1023 (7.5'-8'-7.5')

FT1024 (8.5'-8'-7.5')

FT1025 (9.5'-8'-7.5')

FT1025 (7.5'-8'-9')

FT1026 (8.5'-8'-9')

FT1027 (9.5'-8'-9')

FT1027 (7.5'-8'-11')

FT1028 (8.5'-8'-11')

FT1029 (9.5'-8'-11')

FT1030 (7.5'-8'-15')

FT1031 (8.5'-8'-15')

FT1032 (9.5'-8'-15')

FT1032 (7.5'-8'-17')

FT1033 (8.5'-8'-17')

FT1034 (9.5'-8'-17')

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 4

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 5 of 12

SERVICE CONNECTION W/O CIRCUIT BREAKERS

(5) SERVICE CONNECTIONS AS SHOWN BELOW

ELECTRIC TANK HEAT, DUAL RINSE 9 KW,

BLOWER DRYER HEAT 7 KW & BLOWERS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 70 70 240/60/3 70 70 480/60/3 35 35

53.1 50.0 25.0

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

ELECTRIC L-R

GENERAL NOTES:

(a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS

ROTATED 90 DEGREES FOR SHIPPING.

AFF = ABOVE FINISHED FLOOR

ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4"

WITH LEG ADJUSTMENT.

FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL

WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH

SQUEEZE VALVE.

THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION

INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING

OF UNIT.

ELECTRICAL WARNING:

SERVICE WIRE TEMPERATURE RATING: 90C.

PLUMBING NOTES:

RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER

GALLON FOR BEST RESULTS.

(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE

DISHWASHER IS 40-45 PSI.

(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO

THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F

CONTACT SALES ENGINEERING.

(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR

EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD

WATER SUPPLY LINES AT SERVICE CONNECTION.

VENTILATION NOTES:

(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED

FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE

FOR DOORWAYS.

ELECTRICAL CONNECTIONS

COMMON ON ALL MODELS:

E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS

(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.

79-1/8" AFF

E2 ELECTRIC CONNECTION, VENT FAN CONTROL.

(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

W/O CIRCUIT BREAKERS:

E3 ELECTRIC CONNECTION, MOTORS & CONTROLS,

1" CONDUIT. 79-1/8" AFF

E4 ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20KW.

1" CONDUIT. 79-1/8" AFF

E5 ELECTRIC TANK HEAT CONNECTION, WASH TANK, 22KW.

1" CONDUIT. 79-1/8" AFF

E6 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 9KW.

BLOWER DRYER HEAT, 7KW & BLOWERS.

1" CONDUIT. 79-1/8" AFF

E7 ELECTRIC CONNECTION, BOOSTER, 18KW.

1" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

WITH CIRCUIT BREAKERS:

E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, POWER RINSE HEAT,

BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED).

(TB1) 2" CONDUIT, 79-1/8" AFF

E9 ELECTRIC CONNECTION, WASH HEAT, DUAL RINSE HEAT,

BLOWER DRYER HEAT & BLOWERS (TB2).

2" CONDUIT, 79-1/8" AFF

PLUMBING CONNECTIONS:

P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER

MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).

P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,

1" FPT, 5-1/2" AFF see notes (c) and (d).

P3 COMMON DRAIN CONNECTION.

TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END

OF UNIT, PLUG OPPOSITE END.

2" FPT. 7" AFF

VENTILATION REQUIREMENTS:

V1 MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP

CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR

CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS).

BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED

BY OTHERS).

95-3/8" AFF

MODEL:

FT1000

ENERGY RECOVERY

W/BLOWER DRYER

ELECTRIC

L-R OPERATION

00-949507

REV A2

SERVICE CONNECTION WITH CIRCUIT BREAKERS

(2) SERVICE CONNECTIONS AS SHOWN BELOW

MOTORS,CONTROLS,POWER RINSE & BOOSTER HEAT (TB1)

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 200 200 240/60/3 200 200 480/60/3 125 125

161.3 156.0 86.5

WASH, DUAL RINSE HEAT, B/D HEAT & BLOWERS (TB2)

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208/60/3 119.1 150 150 240/60/3 113.0 150 150 480/60/3 56.5 70 70

ELECTRIC TANK HEAT, POWER RINSE

(1) 20 KW CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

208/60/3 60.0 80 80 240/60/3 57.3 80 80 480/60/3 28.6 40 40

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

ELECTRIC TANK HEAT, WASH

(1) 22 KW CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 66.0 80 80 240/60/3 63.0 80 80 480/60/3 31.5 45 45

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35

ELECTRIC BOOSTER

(1) 18 KW CONNECTION AS SHOWN BELOW

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.

Pressure gauge not required on pumped rinse machines.

MOTORS AND CONTROLS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208-240/60/3 47.2 60 60 480/60/3 32.1 40 40

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 5

Page 6 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

ELECTRIC R-L

MODEL NO. "A" "B" "C"

NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"

7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4"

11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"

23' 3-1/2" 24' 3-1/4" 25' 3-3/32" 24' 11-1/4" 25' 11" 26' 10-27/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 31' 5-15/16" 32' 5-25/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32"

7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"

FT1023 (7.5'-8'-7.5')

FT1024 (8.5'-8'-7.5')

FT1025 (9.5'-8'-7.5')

FT1025 (7.5'-8'-9')

FT1026 (8.5'-8'-9')

FT1027 (9.5'-8'-9')

FT1027 (7.5'-8'-11')

FT1028 (8.5'-8'-11')

FT1029 (9.5'-8'-11')

FT1030 (7.5'-8'-15')

FT1031 (8.5'-8'-15')

FT1032 (9.5'-8'-15')

FT1032 (7.5'-8'-17')

FT1033 (8.5'-8'-17')

FT1034 (9.5'-8'-17')

DIRECTION OF OPERATION

ASR

BLOWER/

DRYER

6"

36 1/2"36 1/4"

3"

35 7/16"35 7/16"35 7/16"25 9/16"

5 3/4"

23 3/4"

6" AIR

GAP

FLOOR LINE

43 5/16"

25 9/16"

7 7/8" OVER FRAME "A" 3 15/16"

UNLOAD "C" 8' 7/16" LOAD "B"

62 3/4"

81 7/8"

V1

EXHAUST HOOD

SUPPLIED BY

OTHERS

89 3/8" SEE NOTE (e)

UNLOAD

END

LOAD

END

POWER

WASH

PRE-

WASH

POWER

RINSE

FNL

RNS

AUX

RNS

P2

V1

P3

V1

E1

E2

E3

P1

P1 P2

P3

E1 E2 E3

P3

E6 E7 E8 E9

E4 E5

E9

E8

E7

E6

E5

E4

18 3/4"

37 1/2"

55 11/16"

63 3/8"

11 13/16"

9 15/16"

23 3/4"

60" 52" 44 9/16"

160 1/16"

22" HIGH X 29-13/16"

WIDE OPENING WILL

HANDLE 18" X 26" BUN PANS

NOTE: CLEARANCE FROM WALL

24" RECOMMENDED, 6" MINIMUM

WITH DETERGENT DISPENSER

ON THE TOP

FLOOR LINE 44 13/16"

SEE NOTE (a)

35"

40 3/8"

NOTE: REFER TO LATEST

EDITION OF NATIONAL

ELECTRICAL CODE AND

LOCAL BUILDING CODES

FOR PROPER CLEARANCE

NOTE: STRAINER PANS

REQUIRE 35" TO

BE REMOVED. EXTRA

CLEARANCE SHOULD BE

PROVIDED.

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 6

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 7 of 12

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

ELECTRIC R-L

SERVICE CONNECTION W/O CIRCUIT BREAKERS

(5) SERVICE CONNECTIONS AS SHOWN BELOW

ELECTRIC TANK HEAT, DUAL RINSE 9 KW,

BLOWER DRYER HEAT 7 KW & BLOWERS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 70 70 240/60/3 70 70 480/60/3 35 35

53.1 50.0 25.0

GENERAL NOTES:

(a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS

ROTATED 90 DEGREES FOR SHIPPING.

AFF = ABOVE FINISHED FLOOR

ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4"

WITH LEG ADJUSTMENT.

FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL

WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH

SQUEEZE VALVE.

THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION

INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING

OF UNIT.

ELECTRICAL WARNING:

SERVICE WIRE TEMPERATURE RATING: 90C.

PLUMBING NOTES:

RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER

GALLON FOR BEST RESULTS.

(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE

DISHWASHER IS 40-45 PSI.

(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO

THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F

CONTACT SALES ENGINEERING.

(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR

EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD

WATER SUPPLY LINES AT SERVICE CONNECTION.

VENTILATION NOTES:

(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED

FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE

FOR DOORWAYS.

ELECTRICAL CONNECTIONS

COMMON ON ALL MODELS:

E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS

(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.

79-1/8" AFF

E2 ELECTRIC CONNECTION, VENT FAN CONTROL.

(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

W/O CIRCUIT BREAKERS:

E3 ELECTRIC CONNECTION, MOTORS & CONTROLS,

1" CONDUIT. 79-1/8" AFF

E4 ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20KW.

1" CONDUIT. 79-1/8" AFF

E5 ELECTRIC TANK HEAT CONNECTION, WASH TANK, 22KW.

1" CONDUIT. 79-1/8" AFF

E6 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 9KW.

BLOWER DRYER HEAT, 7KW & BLOWERS.

1" CONDUIT. 79-1/8" AFF

E7 ELECTRIC CONNECTION, BOOSTER, 18KW.

1" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

WITH CIRCUIT BREAKERS:

E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, POWER RINSE HEAT,

BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED).

(TB1) 2" CONDUIT, 79-1/8" AFF

E9 ELECTRIC CONNECTION, WASH HEAT, DUAL RINSE HEAT,

BLOWER DRYER HEAT & BLOWERS (TB2).

2" CONDUIT, 79-1/8" AFF

PLUMBING CONNECTIONS:

P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER

MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).

P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,

1" FPT, 5-1/2" AFF see notes (c) and (d).

P3 COMMON DRAIN CONNECTION.

TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END

OF UNIT, PLUG OPPOSITE END.

2" FPT. 7" AFF

VENTILATION REQUIREMENTS:

V1 MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP

CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR

CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS).

BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED

BY OTHERS).

95-3/8" AFF

MODEL:

FT1000

ENERGY RECOVERY

W/BLOWER DRYER

ELECTRIC

R-L OPERATION

00-949506

REV A2

SERVICE CONNECTION WITH CIRCUIT BREAKERS

(2) SERVICE CONNECTIONS AS SHOWN BELOW

MOTORS,CONTROLS,POWER RINSE & BOOSTER HEAT (TB1)

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 200 200 240/60/3 200 200 480/60/3 125 125

161.3 156.0 86.5

WASH, DUAL RINSE HEAT, B/D HEAT & BLOWERS (TB2)

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208/60/3 119.1 150 150 240/60/3 113.0 150 150 480/60/3 56.5 70 70

ELECTRIC TANK HEAT, POWER RINSE

(1) 20 KW CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

208/60/3 60.0 80 80 240/60/3 57.3 80 80 480/60/3 28.6 40 40

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

ELECTRIC TANK HEAT, WASH

(1) 22 KW CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 66.0 80 80 240/60/3 63.0 80 80 480/60/3 31.5 45 45

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICES

208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35

ELECTRIC BOOSTER

(1) 18 KW CONNECTION AS SHOWN BELOW

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.

Pressure gauge not required on pumped rinse machines.

MOTORS AND CONTROLS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208-240/60/3 47.2 60 60 480/60/3 32.1 40 40

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 7

Page 8 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

STEAM L-R

18 3/4"

37 1/2" 55 11/16"

63 3/8"

11 13/16"

2 15/16"

33 3/8"

68 13/16"

15 11/16"

9 15/16"

38 1/4"

28 15/16"

28 7/16"

21 3/4"

55 3/16"

51 15/16"

5 15/16" 6 3/4" 11 9/16"

14 11/16"

23 1/8"

44 9/16"

33"

23 3/4"

23"

160 1/16"

P4

P1

V1

P8

P3

V1

E1

E2

E3

P7

P7

P7

P7 P6

P5

P9

P2

P1

P2

P3

E1E2E3

P4

P3

P5

P6

P8

P9

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.

Pressure gauge not required on pumped rinse machines.

DIRECTION OF OPERATION

ASR

BLOWER/

DRYER

6"

36 1/2"

62 3/4"

36 1/4"

3"

35 7/16" 35 7/16" 35 7/16" 25 9/16"

5 3/4"

23 3/4"

6" AIR

GAP

FLOOR LINE

43 5/16"

25 9/16"

3 15/16" OVER FRAME "A" 7 7/8"

UNLOAD "C"

81 7/8"

LOAD "B" 8' 7/16"

V1

EXHAUST HOOD

SUPPLIED BY

OTHERS

LOAD

END

UNLOAD

ENDAUX

RNS

FNL

RNS

POWER

WASH

PRE-

WASH

POWER

RINSE

89 3/8" SEE NOTE (f)

MODEL:

FT1000 ENERGY RECOVERY

W/BLOWER DRYER

STEAM

L-R OPERATION

00-949507

REV A2

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 8

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 9 of 12

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

STEAM L-R

22" HIGH X 29-13/16"

WIDE OPENING WILL

HANDLE 18" X 26" BUN PANS

NOTE: CLEARANCE FROM WALL

24" RECOMMENDED, 6" MINIMUM

WITH DETERGENT DISPENSER

ON THE TOP

44 13/16" SEE NOTE (a)

FLOOR LINE

35"

NOTE: STRAINER PANS

REQUIRE 35" TO

BE REMOVED. EXTRA

CLEARANCE SHOULD BE

PROVIDED.

40 3/8"

NOTE: REFER TO LATEST

EDITION OF NATIONAL

ELECTRICAL CODE AND

LOCAL BUILDING CODES

FOR PROPER CLEARANCE

MODEL NO. "A" "B" "C"

NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"

7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4"

11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"

23' 3-1/2" 24' 3-1/4" 25' 3-3/32" 24' 11-1/4" 25' 11" 26' 10-27/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 31' 5-15/16" 32' 5-25/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32"

7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"

FT1023 (7.5'-8'-7.5')

FT1024 (8.5'-8'-7.5')

FT1025 (9.5'-8'-7.5')

FT1025 (7.5'-8'-9')

FT1026 (8.5'-8'-9')

FT1027 (9.5'-8'-9')

FT1027 (7.5'-8'-11')

FT1028 (8.5'-8'-11')

FT1029 (9.5'-8'-11')

FT1030 (7.5'-8'-15')

FT1031 (8.5'-8'-15')

FT1032 (9.5'-8'-15')

FT1032 (7.5'-8'-17')

FT1033 (8.5'-8'-17')

FT1034 (9.5'-8'-17')

GENERAL NOTES:

(a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS

ROTATED 90 DEGREES FOR SHIPPING.

AFF = ABOVE FINISHED FLOOR

ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4"

WITH LEG ADJUSTMENT.

FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL

WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH

SQUEEZE VALVE.

THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION

INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING

OF UNIT.

ELECTRICAL WARNING:

SERVICE WIRE TEMPERATURE RATING: 90C.

VENTILATION NOTES:

(f) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED

FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR

DOORWAYS.

PLUMBING NOTES:

RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER

GALLON FOR BEST RESULTS.

(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE

DISHWASHER IS 40-45 PSI.

(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE

DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F

CONTACT SALES ENGINEERING.

(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR

EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD

WATER SUPPLY LINES AT SERVICE CONNECTION.

(e) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE

AT THE DISHWASHER, CONTACT SALES ENGINEERING.

ELECTRICAL CONNECTIONS

COMMON ON ALL MODELS:

E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS

(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.

79-1/8" AFF

E2 ELECTRIC CONNECTION, VENT FAN CONTROL.

(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

WITH & W/O CIRCUIT BREAKERS:

E3 ELECTRIC CONNECTION, MOTORS & CONTROLS,

1" CONDUIT. 79-1/8" AFF

PLUMBING CONNECTIONS:

P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER

MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).

P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,

1" FPT, 5-1/2" AFF see notes (c) and (d).

P3 COMMON DRAIN CONNECTION.

TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END

OF UNIT, PLUG OPPOSITE END.

2" FPT. 7" AFF

P4 COMMON STEAM CONNECTION (TANK HEAT, STEAM BOOSTER &

BLOWER DRYER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE)

see note (e).

P5 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)

1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR.

16-15/16" AFF

P6 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)

3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR.

15-9/16" AFF

P7 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),

BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.

3/4" FPT, 11" AFF

P8 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER

OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.

3/4" FPT, 4-3/4" AFF

P9 CONDENSATE RETURN, GRAVITY CONNECTION (STEAM BLOWER DRYER),

BUCKET TYPE TRAP FURNISHED.

3/4" FPT, 13" AFF

VENTILATION REQUIREMENTS:

V1 MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP

CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR

CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS).

BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED

BY OTHERS).

95-3/8" AFF

MOTORS AND CONTROLS

SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208-240/60/3 54.5 70 70 480/60/3 36.4 45 45

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 9

Page 10 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

STEAM R-L

18 3/4"

37 1/2"

55 11/16"

63 3/8"

11 13/16"

22 5/8" 53 3/8"

88 3/4"

15 11/16"

9 15/16"

38 1/4"

28 15/16"

28 7/16"

23 3/4"

60"

52"

5 7/8"

32 15/16"

6 3/4"

11 5/8"

14 5/8"

23 1/8"

44 9/16"

23 1/16"

160 1/16"

P4

P2

V1

P8

P3

V1

E1

E2

E3

P7

P7

P7

P7P6

P8

P9

P1

P1 P2

P3

E1 E2 E3

P4

P3

P5 P6

P5

P9

DIRECTION OF OPERATION

ASR

BLOWER/

DRYER

6"

36 1/2"36 1/4"

3"

35 7/16"35 7/16"35 7/16"25 9/16"

5 3/4"

23 3/4"

6" AIR

GAP

FLOOR LINE

7 3/16" 3 15/16"

UNLOAD "C"

OVER FRAME "A"

43 5/16"

25 9/16"

81 7/8"

8' 7/16" LOAD "B"

62 3/4"

V1

EXHAUST HOOD

SUPPLIED BY

OTHERS

89 3/8" SEE NOTE (f)

UNLOAD

END

LOAD

END

POWER

WASH

PRE-

WASH

POWER

RINSE

AUX

RNS

FNL

RNS

MODEL:

FT1000 ENERGY RECOVERY

W/BLOWER DRYER

STEAM

R-L OPERATION

00-949506

REV A2

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.

Pressure gauge not required on pumped rinse machines.

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 10

F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 11 of 12

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER,

STEAM R-L

MODEL NO. "A" "B" "C"

NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"

7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4"

11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"

23' 3-1/2" 24' 3-1/4" 25' 3-3/32" 24' 11-1/4" 25' 11" 26' 10-27/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 31' 5-15/16" 32' 5-25/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32"

7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"

FT1023 (7.5'-8'-7.5')

FT1024 (8.5'-8'-7.5')

FT1025 (9.5'-8'-7.5')

FT1025 (7.5'-8'-9')

FT1026 (8.5'-8'-9')

FT1027 (9.5'-8'-9')

FT1027 (7.5'-8'-11')

FT1028 (8.5'-8'-11')

FT1029 (9.5'-8'-11')

FT1030 (7.5'-8'-15')

FT1031 (8.5'-8'-15')

FT1032 (9.5'-8'-15')

FT1032 (7.5'-8'-17')

FT1033 (8.5'-8'-17')

FT1034 (9.5'-8'-17')

22" HIGH X 29-13/16"

WIDE OPENING WILL

HANDLE 18" X 26" BUN PANS

NOTE: CLEARANCE FROM WALL

24" RECOMMENDED, 6" MINIMUM

WITH DETERGENT DISPENSER

ON THE TOP

FLOOR LINE 44 13/16"

SEE NOTE (a)

35"

40 3/8"

NOTE: REFER TO LATEST

EDITION OF NATIONAL

ELECTRICAL CODE AND

LOCAL BUILDING CODES

FOR PROPER CLEARANCE

NOTE: STRAINER PANS

REQUIRE 35" TO

BE REMOVED. EXTRA

CLEARANCE SHOULD BE

PROVIDED.

VENTILATION REQUIREMENTS:

V1 MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP

CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR

CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS).

BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED

BY OTHERS).

95-3/8" AFF

GENERAL NOTES:

(a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS

ROTATED 90 DEGREES FOR SHIPPING.

AFF = ABOVE FINISHED FLOOR

ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4"

WITH LEG ADJUSTMENT.

FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL

WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH

SQUEEZE VALVE.

THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION

INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING

OF UNIT.

ELECTRICAL WARNING:

SERVICE WIRE TEMPERATURE RATING: 90C.

PLUMBING NOTES:

RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER

GALLON FOR BEST RESULTS.

(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE

DISHWASHER IS 40-45 PSI.

(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE

DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F

CONTACT SALES ENGINEERING.

(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR

EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD

WATER SUPPLY LINES AT SERVICE CONNECTION.

(e) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE

AT THE DISHWASHER, CONTACT SALES ENGINEERING.

VENTILATION NOTES:

(f) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED

FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR

DOORWAYS.

ELECTRICAL CONNECTIONS

COMMON ON ALL MODELS:

E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS

(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.

79-1/8" AFF

E2 ELECTRIC CONNECTION, VENT FAN CONTROL.

(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF

ELECTRICAL CONNECTIONS

WITH & W/O CIRCUIT BREAKERS:

E3 ELECTRIC CONNECTION, MOTORS & CONTROLS,

1" CONDUIT. 79-1/8" AFF

PLUMBING CONNECTIONS:

P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER

MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).

P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,

1" FPT, 5-1/2" AFF see notes (c) and (d).

P3 COMMON DRAIN CONNECTION.

TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END

OF UNIT, PLUG OPPOSITE END.

2" FPT. 7" AFF

P4 COMMON STEAM CONNECTION (TANK HEAT, STEAM BOOSTER &

BLOWER DRYER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE)

see note (e).

P5 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)

1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR.

16-15/16" AFF

P6 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)

3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR.

15-9/16" AFF

P7 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),

BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.

3/4" FPT, 11" AFF

P8 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER

OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.

3/4" FPT, 4-3/4" AFF

P9 CONDENSATE RETURN, GRAVITY CONNECTION (STEAM BLOWER DRYER),

BUCKET TYPE TRAP FURNISHED.

3/4" FPT, 13" AFF

MOTORS AND CONTROLS

SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS

(1) SERVICE CONNECTION AS SHOWN BELOW

ELEC.

SPECS.

RATED

AMPS

MINIMUM

SUPPLY

CONDUCTOR

AMPACITY

MAXIMUM

PROTECTIVE

DEVICE

208-240/60/3 54.5 70 70 480/60/3 36.4 45 45

Aldevra Lead 9158 ‐ 36C252‐18‐Q‐0554 ‐ VAMC Gill Marke ng Co., a division of Gill Group, Inc. Page: 11

Page 12 of 12 F40392 – FT1000 Energy Recovery with Blower Dryer Flight-Type Dishwasher

As continued product improvement is a policy of Hobart, specifications are subject to change without notice.

FT1000 ENERGY RECOVERY

WITH BLOWER DRYER

FLIGHT-TYPE DISHWASHER

FT1000 Energy Recovery with Blower Dryer Series (7.5, 9 Load / 8 Center / 7.5, 9, 11 Unload)

Machine Ratings (Mechanical) Conveyor Speed — Feet per minute 4.0 - 8.5

Dishes per Hour 14,316

Motor — Horsepower ASR Soil - 1⁄4; ASR Wash - 1⁄3; Pre-Wash - 31⁄2; Wash - 5; Rinse - 5;

Dual Rinse - 1⁄6; Final Rinse - 1⁄2; Conveyor - 1⁄3; Blower Dryer (2) 2

Tank Capacity — Gallons ASR - 7.2; Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 7.2

Rate of Final Rinse — Gallons per minute (Pumped rinse) .97

Final Rinse Consumption — Gallons per hour (Pumped rinse) 58

Exhaust Requirements — Cubic feet per minute 750 (at standard air conditions)

Latent/Sensible Heat — BTU per hour Electric - Latent: 87,400 / Sensible: 37,400 Steam - Latent: 103,900 / Sensible: 44,500

Electric Heat Requirements —

Tank Heat - Kilowatt (Regulated)

Optional Electric Booster - Kilowatt

Optional Blower Dryer - Kilowatt

Disconnect switches are recommended for each power circuit connected to dishwasher. These disconnect switches are NOT furnished by Hobart and should be installed by the electrical contractor at the time of installation.

Circuit breakers optional at extra cost.

Total tank heat - 51KW (Wash, Rinse, Dual Rinse)

18KW - 110°F incoming water raised to 185°F (75°F rise) (180°F minimum)

7.0 KW

Steam Heat Requirements —

Steam Consumption

Tank Heat - Pounds per hour - maximum (Regulated) - based on 10 to 45 PSI steam at the machine

Optional Steam Booster - Pounds per hour - maximum

- based on 20 PSI steam, 110°F incoming water raised to 185°F (75°F rise) (180°F minimum)

Optional Steam Blower Dryer - Pounds per hour -maximum - based on 20 PSI steam

213 lbs./150°F Wash minimum - 160°F Rinse minimum - 160°F Dual Rinse minimum

42 lbs./180°F Final Rinse minimum

30 lbs.

Peak Rate of Drain Flow — Gallons per minute Initial rate with full tanks 38

Shipping Weight Crated Varies by individual model - consult your Hobart representative

FT (flight type) Models—many additional variations of these model specifications are available. Engineering data furnished on request. Numbers in parentheses, after model number from left to right, represent length in feet of the following respectively; Loading section, Washing and Power Rinsing sections, Unloading section.

F40392 (REV. 09/14) LITHO IN U.S.A. (H-01)