About this file

36C25218B0731 00002 S06 Amendment 00002 Revised Drawings.pdf

View the file

Other files

File Type Posted
36C25218C0175-000.docx DOCX document
36C25218B0731-00002000.docx DOCX document
36C25218B0731-00001000.docx DOCX document
36C25218B0731-00001001.pdf PDF
36C25218B0731-010.pdf PDF
36C25218B0731-006.pdf PDF
36C25218B0731-008.pdf PDF
36C25218B0731-007.pdf PDF
36C25218B0731-005.pdf PDF
36C25218B0731-009.pdf PDF
36C25218B0731-001.docx DOCX document
36C25218B0731-002.pdf PDF
36C25218B0731-011.pdf PDF
36C25218B0731-003.pdf PDF
36C25218B0731-004.pdf PDF
36C25218B0731-000.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building Number:

Project Number:

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATIONS

013-001

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

38 39

BUILDING 112

0' 8' 32'16'

1. WINDOW REQUIREMENTS - WHEN BELOW 12 M (40 FT.) FROM GROUND

LEVEL OR THE ROOF OF A LOWER ABUTMENT, OR LESS THAN 7.5 M

(25FT.) FROM WINDOWS OF AN ADJOINING BUILDING, OR ACCESSIBLE BY

A BUILDING LEDGE LEADING TO WINDOWS OF OTHER FLOOR ROOMS,

SECURITY MESH SCREENING FOR WINDOWS IS REQUIRED. SECURITY

MEASURES THAT EXCEED THESE REQUIREMENTS MAY BE AUTHORIZED

IN WRITING BBY OS&LE. REQUIRED SPECIFICATIONS FOR STAINLESS

STEEL SECURITY MESH SCREENING ARE

A. ALL #304 STAINLESS STEEL WOVEN MESH 0.7 MM (.028 IN.) WIRE

DIAMTER, WITH TENSILE STRENGTH OF 15KG/MM (800 POUNDS PER

LINEAR INCH).

B. MESH 12X12 PER 25 MM (1 IN.) WITH MAIN AND SUB FRAMES OF 2.7

MM (12 GUAGES) CARBON STEEL WITH BAKED ENAMEL FINISH AND

INTERNAL KEY LOCKING SLIDE BOLTS.

NOT IN CONTRACT

SUBTASK 13 - B112 SECURITY SCREENING

013-002

013-002

013-002

013-002

013-002

013-002

Amendment Clarity; VAResponse 5/2/2018

VA Police have four main requirements with the security screening sub-task:

1) Security screens shall not be removable from the exterior of the building. Fasteners or hardware shall be used to prevent opening from the outside.

2) Tensile strength shall be at least 800 lbs/in as noted above.

3) Materials shall be stainless steel, galvanized steel or painted/coated steel to resist corrosion.

4) Security screens shall be installed so that windows as identified can open. See following pages for specific details.

design amendment 5/2/18

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATIONS

013-001

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

38 39

BUILDING 112

0' 8' 32'16'

1. WINDOW REQUIREMENTS - WHEN BELOW 12 M (40 FT.) FROM GROUND

LEVEL OR THE ROOF OF A LOWER ABUTMENT, OR LESS THAN 7.5 M

(25FT.) FROM WINDOWS OF AN ADJOINING BUILDING, OR ACCESSIBLE BY

A BUILDING LEDGE LEADING TO WINDOWS OF OTHER FLOOR ROOMS,

SECURITY MESH SCREENING FOR WINDOWS IS REQUIRED. SECURITY

MEASURES THAT EXCEED THESE REQUIREMENTS MAY BE AUTHORIZED

IN WRITING BBY OS&LE. REQUIRED SPECIFICATIONS FOR STAINLESS

STEEL SECURITY MESH SCREENING ARE

A. ALL #304 STAINLESS STEEL WOVEN MESH 0.7 MM (.028 IN.) WIRE

DIAMTER, WITH TENSILE STRENGTH OF 15KG/MM (800 POUNDS PER

LINEAR INCH).

B. MESH 12X12 PER 25 MM (1 IN.) WITH MAIN AND SUB FRAMES OF 2.7

MM (12 GUAGES) CARBON STEEL WITH BAKED ENAMEL FINISH AND

INTERNAL KEY LOCKING SLIDE BOLTS.

NOT IN CONTRACT

SUBTASK 13 - B112 SECURITY SCREENING

013-002

013-002

013-002

013-002

013-002

013-002

Amendment Clarity; VAResponse 5/2/2018

VA Police have four main requirements with the security screening sub-task:

1) Security screens shall not be removable from the exterior of the building. Fasteners or hardware shall be used to prevent opening from the outside.

2) Tensile strength must be at least 800 lbs/in as noted above.

3) Materials can be stainless steel, galvanized steel or painted/coated steel to resist corrosion.

Again, key requirement is tensile strength.

4) Security screens shall be installed so that some of the windows can open. See following pages for specific details.

design amendment 5/2/18

EXAMPLES

A

Bldg 70, K-wing west. Hinged vertically, stainless steel mesh. Cannot be opened from outside. Flush with exterior wall.

Bldg 108 south. Steel - galvanized. Larger middle section so that window can be opened from inside.

Cannot be opened from outside.

Bldg 70, E-wing west. Painted steel. Cannot be opened from outside. Flush with exterior wall.

Bldg 102, south. Hinged vertically, painted and stainless steel mesh. Cannot be opened from outside. Flush with exterior wall.

The above security screening examples all meet VA Security requirements. They are tamper-proof from the exterior and cannot easily be opened with a screw-driver or tool from the outside. They meet or exceed the tensile strength requirements. Where required, the security screen allows the window to open for ventilation. Acceptable materials include stainless steel, galvanized steel or painted steel to prevent corrosion.

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATION PICS

013-002

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

39 39

EAST SIDE OF BUILDING 112

SOUTH SIDE OF BUILDING 112

SUBTASK 13 - B112 SECURITY SCREENING

1 2

3 4 5

Security screens on the windows on the east side of Bldg 112 shall be installed in such a manner that will allow the windows to open. To that extent, the screening shall NOT be flush with the exterior wall for the southern three (3) windows. The fourth window, with the AC unit, shall have a security screen system that is flush with the exterior wall (window will not open). For the three (3) windows that open, bid a screen system that will allow them to be opened 8-inches from the inside. Security screens shall be secured with fasteners so that they cannot be removed or operated from the exterior. Screen materials shall be stainless steel, galvanized steel, or painted steel to resist corrosion. Tensile strength shall meet or exceed 800 lbs/linear inch. See campus examples for acceptable security screening solution systems. GC to provide fabrication shop drawings during submittal phase for VA review and approval. Contractor to verify actual dimensions required with field measurements. Rough opening measurements: 2.7ft x 5.3ft each (four windows).

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATION PICS

013-002

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

39 39

EAST SIDE OF BUILDING 112

SOUTH SIDE OF BUILDING 112

SUBTASK 13 - B112 SECURITY SCREENING

1 2

3 4 5

Security screens on these windows on the south side of Bldg 112 shall be installed flush with the exterior wall - the windows do not operate/open. Security screens shall be secured with fasteners so that they cannot be removed or operated from the exterior. Screen materials shall be stainless steel, galvanized steel, or painted steel to resist corrosion. Tensile strength shall meet or exceed 800 lbs/linear inch. See campus examples for acceptable security screening solution systems. GC to provide fabrication shop drawings during submittal phase for VA review and approval. Contractor to verify actual dimensions required with field measurements. Rough opening measurements: 2.7ft x 7.3ft each (three windows).

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATION PICS

013-002

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

39 39

EAST SIDE OF BUILDING 112

SOUTH SIDE OF BUILDING 112

SUBTASK 13 - B112 SECURITY SCREENING

1 2

3 4 5

Security screens on these windows on the south side of Bldg 112 shall be installed in such a manner that will allow the windows to open. To that extent, the screening shall NOT be flush with the exterior wall. For these windows, bid a screen system that will allow them to be opened 8-inches from the inside. Security screens shall be secured with fasteners so that they cannot be removed or operated from the exterior. Screen materials shall be stainless steel, galvanized steel, or painted steel to resist corrosion. Tensile strength shall meet or exceed 800 lbs/linear inch. See campus examples for acceptable security screening solution systems. GC to provide fabrication shop drawings during submittal phase for VA review and approval. Contractor to verify actual dimensions required with field measurements. Rough opening measurements: 2.7ft x 12.5ft each (five windows).

Drawing Number:

Dwg. of

DrawnCheckedDate:

Location:

Project Title:

Drawing Title:

ARCHITECT/ENGINEERS:

Approved (Project Director):

Michelle Dittloff

Revisions:

Date

VA FORM 08-6231

Clement J. Zablocki VAMC

Facility Management Division

Engineer: James Beier

Office of

Construction and Facilities

Management

695-18-119

JLDJLB03-01-2018

FY 2018 TJC AND SAFETY

CORRECTIONS

Milwaukee VAMC, Milwaukee, WI

BUILDING 112 SECURITY SCREEN

LOCATION PICS

013-002

Milwaukee, WI

Medical Center

5000 W. National Avenue

Dept. of Veterans Affairs

39 39

EAST SIDE OF BUILDING 112

SOUTH SIDE OF BUILDING 112

SUBTASK 13 - B112 SECURITY SCREENING

1 2

3 4 5

Security screens on these windows on the south side of Bldg 112 shall be installed in such a manner that will allow the windows to open. To that extent, the screening shall NOT be flush with the exterior wall. For these windows, bid a screen system that will allow them to be opened 8-inches from the inside. (Work around the HVAC vent - screening not required at vent in window - see cloud.) Security screens shall be secured with fasteners so that they cannot be removed or operated from the exterior. Screen materials shall be stainless steel, galvanized steel, or painted steel to resist corrosion. Tensile strength shall meet or exceed 800 lbs/linear inch. See campus examples for acceptable security screening solution systems. GC to provide fabrication shop drawings during submittal phase for VA review and approval. Contractor to verify actual dimensions required with field measurements. Rough opening measurements: 2.7ft x 15.8ft each (four windows).