This document is a National Health Physics Program (NHPP) newsletter dated October 30, 2026, containing guidance on radiation safety hazards and federal contract implementation.

The first section addresses an incident involving VA Police service weapons destroyed with tritium gun sights still attached. Tritium gun sights contain sealed glass vials filled with tritium (H-3) gas, typically ranging in tens of millicuries per vial, designed to improve visibility in low-light conditions. Tritium is a low-energy pure beta emitter with a 12.3-year half-life that presents virtually no external radiation hazard but can pose an internal hazard if released in large quantities through inhalation or skin absorption. The recommended precautionary response to a breached tritium sight includes: vacating the area for a minimum of 10 minutes, wearing gloves (double-gloving preferred), placing the damaged sight in a hardened container using double-bag technique for disposal through a licensed waste broker, and washing hands thoroughly with soap and lukewarm water. For suspected contamination events, immediate washing with soap and water is recommended, followed by employee reporting to Employee Health to document potential exposure. The NHPP recommends that Radiation Safety Officers ensure VA Police personnel receive awareness training on radiation safety hazards associated with tritium gun sights, with emphasis on proper Logistics and GSA weapons destruction and waste disposal procedures.

The second section addresses Patient Radiation Dose Tracking (PRDT), a national contract awarded to AGFA DoseMonitor as part of Electronic Health Record Modernization (EHRM). PRDT implementation requires installation of DoseMonitor software and virtual servers configured to connect with diagnostic imaging equipment including CT, fluoroscopy, mammography, and MRI systems. Implementation is expected to take approximately one year, with priority given to facilities not yet configured for the Radiation Exposure Monitoring (REM) Registry. PRDT requires Point of Contract representatives for HTM, RSO, and PACS Administrator. RSOs will coordinate with facility teams to establish imaging equipment connectivity and will receive contact from the PRDT team regarding deployment schedule, implementation, and training. For PRDT implementation questions, facilities should contact Ron Leuenberger, CHP, National Radiation Safety Committee RSO Representative, at (216) 217-6506 or Ronald.Leuenberger@va.gov.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NHPP Scatterings October 30, 2026

Tritium Gun Sites

In August 2026, the National Health Physics Program (NHPP) became aware of an incident in which VA Police service weapons were destroyed before the tritium gun sights had been removed. Note: Under 10 CFR § 32.22 the manufacturers or distributors of tritium gun sights must hold a specific license per 10 CFR § 32.23 and may distribute the gun sights as "exempt" sources to end-users. This underscores the low exposure potential associated with unintended release of the tritium filled vials. In the case reviewed by NHPP, the weapons destruction process incorporated the use of an acetylene torch, which breached the tritium-containing gun sight vials. This special edition newsletter provides guidance on the hazards associated with tritium gun sights and the appropriate response procedures should a sight be damaged or breached.

Background: Tritium gun sights contain sealed glass vials filled with tritium (H-3) gas, typically ranging in the tens of millicuries (mCi) per vial. These sights are designed to improve visibility in low-light conditions. Tritium is a low-energy, pure beta emitter (maximum energy 18.6 keV) with a physical half-life of 12.3 years. The emitted beta particles interact with a phosphor coating inside the vial, producing a visible glow. While the NRC considers these devices to present minimal exposure risk during normal use, they must be disposed of in an environmentally responsible manner when removed from service. Appropriate disposal methods for intact gun sights include return to the manufacturer or disposal through an approved waste broker.

Health and Safety Considerations: Tritium presents virtually no external radiation hazard because of the very low energy of the beta particles it emits. However, it can present an internal radiation hazard if released in large quantities (e.g., aggregate, simultaneous release during destruction of 10 gun sights). The most likely route of contamination following a breach is through inhalation and skin absorption. Once released, tritium gas rapidly combines with oxygen to form tritiated water vapor. This vapor can be inhaled or absorbed through the skin, where the body processes the tritium as water and uniformly incorporates and distributes it into body tissues.

Precautionary Response to a Breached Tritium Sight: If a tritium sight is broken or otherwise compromised, typical response measures are as follows:

* Vacate the area for a minimum of 10 minutes to allow released tritium gas to dissipate.

* Do not handle broken sight components with bare hands. Wear gloves, with double-gloving preferred.

* Place the damaged sight into a hardened container, employ double bag technique, and transfer it to an appropriate radioactive waste container for disposal through a licensed waste broker.

* Wash hands thoroughly with soap and lukewarm water after securing the damaged sight.

Tritium Gun Sites

Suspected Contamination Events: Because tritium emits very low-energy beta radiation, it cannot be detected using most handheld survey instruments. A liquid scintillation counter (LSC), found in VA facilities that have active Research, serve as the preferred method for detecting and quantifying tritium contamination. In the case evaluated by NHPP, the LSC sample results collected from the individual, equipment, and facility surfaces were insignificant --confirming a low exposure potential. If contamination is suspected, use a common-sense, risk-informed approach. For example:

* Wash the affected area immediately with soap and water to reduce absorption.

* Instruct the employee to report to Employee Health to document potential exposure in the Employee Health Record and seek medical guidance (e.g., increasing fluid intake to aid in clearing tritium from tissues, if appropriate).

* Ensure that VA Police receive general radiation safety awareness training on hazards associated with tritium gun sites - emphasis placed on following proper Logistics and GSA weapons destruction and waste disposal procedures.

Action Recommended: Radiation Safety Officers (RSO) should ensure that VA Police personnel and others responsible for destroying firearms with tritium sights receive awareness training on radiation safety hazards. They should also be made aware of the VA Law Enforcement Training Center's bulletin released on Destroying Station-Owned Firearms (VA Police SharePoint Link) with a reminder that you are there to support proper weapons decommissioning activities with respect to H-3 sights. VA Police adherence to established weapons destruction procedures will help prevent unnecessary low-level contamination events and exhaustive follow-up assessments by radiation safety staff. This training could be incorporated into routine radiation safety awareness training provided to VA Police.

Patient Radiation Dose Tracking (PRDT)

Patient Radiation Dose Tracking (PRDT), part of Electronic Health Record Modernization (EHRM), is a national contract awarded to AGFA DoseMonitor. As national level begins roll out it will provide a single registry for dose tracking across VHA and give NHPP and RSOs a unified platform, with standardized templates, reports, and notifications, for VHA facilities.

Implementation of PRDT requires installation of software (i.e., DoseMonitor) and virtual servers (i.e., EHRM) and requires Point of Contract (POC) representatives for:

* HTM

* RSO

* PACS Administrator https://dvagov.sharepoint.com/sites/vacotheofficeofsecuritylawenforcementsharepoint/SitePages/Destroying-Station-Owned-Firearms--Know-the-Process.aspx?from=SendByEmail&NewsLetter=true&origin=footer&xsdata=MDV8MDJ8fDliYzlmNTMxM2Q3YzRlMmI3NDIwMDhkZjIzYjVjNzQ0fGU5NWYxYjIzYWJhZjQ1ZWU4MjFkYjdhYjI1MWFiM2JmfDB8MHw2MzkyNjg5MzU3NzcyOTIzNDB8VW5rbm93bnxUV0ZwYkdac2IzZDhleUpGYlhCMGVVMWhjR2tpT25SeWRXVXNJbFlpT2lJd0xqQXVNREF3TUNJc0lsQWlPaUpYYVc0ek1pSXNJa0ZPSWpvaVRXRnBiQ0lzSWxkVUlqb3lmUT09fDB8fHw%3d&sdata=dkVqRGhGRlM4ODM1elR0ZlZTbGNaWUw4S2VBc0lReXF6RWh6UHFxUlc1WT0%3d)

Many VHA facilities are already connected to DoseMonitor (also known as Nexodose), the Radiation Exposure Monitoring (REM) Registry, or both. PRDT will extend the REM Registry to all VHA facilities.

PRDT implementation is expected to take approximately one year, with priority given to facilities not yet configured for the REM Registry. Software and virtual servers will be configured to connect with diagnostic imaging equipment, including CT, fluoroscopy, mammography, and MRI systems.

RSOs will coordinate with facility teams, including HTM and ADPAC, to establish imaging equipment connectivity. The PRDT team will contact the RSO POC with information about the deployment schedule, implementation, and training.

PRDT is linked to EHRM allowing NHPP and RSOs to have virtual real time access to patient dose and imaging quality assurance. Should you have questions regarding PRDT implementation, please contact: Ron Leuenberger, CHP, National Radiation Safety Committee, RSO Representative at (216) 217-6506 or Ronald.Leuenberger@va.gov.