This pre-solicitation notice announces the Department of Veterans Affairs' intent to advertise an invitation for bid for roof replacement services at various buildings on the Battle Creek Veterans Administration Medical Center campus. The project scope involves furnishing all labor, materials, equipment and supervision to replace roofs on six buildings, with a performance period of 240 calendar days from notice to proceed. The estimated value is between $1 million and $5 million. The NAICS code is 238160 and size standard is $16.5 million. This acquisition is reserved 100% for qualified Service-Disabled Veteran Owned Small Businesses. The solicitation will be available for download on March 22, 2022 via the SAM.gov website. Offerors must be registered in SAM and Vendor Information Pages and have valid representations and certifications on file. Questions may be directed to the specified contracting specialist by email only.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Notice of Award - Contract 36C25022C0218 Project 515-21-104.pdf | ||
| S02 - RFI Form 515-21-104.pdf | ||
| 36C25022B0027.pdf | ||
| 515-21-104 Bid Specifications - Full Set.pdf | ||
| Davis-Bacon Act WD MI20220079 Mod 4 - 06-24-2022 Calhoun County.pdf | ||
| S02 Contractor EMR Certification Form 2021 515-21-104.pdf | ||
| 36C25022B0027_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design, Inc. and shall not be used for any purpose without prior expressed written consent.
The Owner shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.net
NORTH
REFERENCE
PROJECT # SIGNATURE DATE
Director Associate Director Chief of Staff Associate Director for Patient Services Chief, FMS Chief, Engineering Section Infectious Control Officer Safety Specialist Chief, Fire Station Union Safety Representative Contracting Officer Contracting Officer Representative
VA PROJECT NO.:
FINAL BID DOCUMENTS
01 26OF
LOCATION MAP VICINITY MAP
Z:
\V iri di an \P ro je ct s\
\0
D R
AW
IN
G S\
R
EV
IT
\L
O C
AL
F
IL
ES
\5
-2 1-
4_
C
AM
PU
SP
LA
N
_C
EN
TR
AL
_R
_d ro an .rv t
/1 5/
:2
6:
P M
GI001
COVER SHEET REPLACE ROOFS, VARIOUS
BUILDINGS PHASE II
515-21-104
CAMPUS PLAN
11/16/2021 TWT JMP
REPLACE ROOFS, VARIOUS BUILDINGS PHASE II
515-21-104
515-21-104
BATTLE CREEK. MICHIGAN
BATTLE CREEK VETERANS AFFAIRS MEDICAL CENTER
BATTLE CREEK VA MEDICAL CENTER
5500 Armstrong Road Battle Creek, Michigan
49037
INDEX OF WORKING DRAWINGS
SHEET NO DRAWING TITLE DRAWING N0
05.AS500 BUILDING 05 - SECTION DETAILS 13
05.AS501 BUILDING 05 - SECTION DETAILS 14
06.AD200 BUILDING 06 - DEMOLITION ROOF PLAN 15
06.AS200 BUILDING 06 - ROOF PLAN 16
06.AS500 BUILDING 06 - SECTION DETAILS 17
06.AS501 BUILDING 06 - SECTION DETAILS 18
134.AD200 BUILDING 134 - DEMOLITION ROOF PLAN 19
134.AS200 BUILDING 134 - ROOF PLAN 20
134.AS500 BUILDING 134 - SECTION DETAILS 21
134.AS501 BUILDING 134 - SECTION DETAILS 22
138.AD200 BUILDING 138 - DEMOLITION ROOF PLAN 23
138.AS200 BUILDING 138 - ROOF PLAN 24
138.AS500 BUILDING 138 - SECTION DETAILS 25
138.AS501 BUILDING 138 - SECTION DETAILS 26
INDEX OF WORKING DRAWINGS
SHEET NO DRAWING TITLE DRAWING N0
GENERAL
GI001 COVER SHEET 01
GI002 ARCHITECTURAL - ABBREVIATIONS AND SYMBOLS 02
GI003 CAMPUS PLAN 03
ARCHITECTURAL
02.AD200 BUILDING 02 - DEMOLITION ROOF PLAN 04
02.AS200 BUILDING 02 - ROOF PLAN 05
02.AS500 BUILDING 02 - SECTION DETAILS 06
03.AD200 BUILDING 03 - DEMOLITION ROOF PLAN 07
03.AS200 BUILDING 03 - ROOF PLAN 08
03.AS500 BUILDING 03 - SECTION DETAILS 09
03.AS501 BUILDING 03 - SECTION DETAILS 10
05.AD200 BUILDING 05 - DEMOLITION ROOF PLAN 11
05.AS200 BUILDING 05 - ROOF PLAN 12
LOCATION
OF PROJECT
W. DICKMAN RD.
N.
8T H
ST
URBAN DR.
CLARK RD. N
N.
8T H
ST
W. DICKMAN RD.
CL
AR
K
RD
. N
.URBAN DR.
W. DICKMAN RD.
Revisions: Date:
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEV BEVEL
BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BOT BOTTOM
BR BEDROOM
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS CHANNEL
C CHANNEL CELSIUS
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN OR CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY OR CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
cm² SQUARE CENTIMETER cm³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF OCCUPANCY,
CLEANOUT, OR COMPANY
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER CONTOUR
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM,
OR DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FV FIELD VERIFY
FWC FABRIC WALLCOVERING
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HQ HEADQUARTERS
HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE LATENT HEAT RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM
MED MEDIUM MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING OR MOTOR OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE DIMENSION
OD OUTSIDE DIMENSION OUTSIDE DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION
OUT OUTLET
OZ OUNCE
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND CEMENT
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PO POST OFFICE PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY REFRIGERATION
REFR REFRIGERATION REFRACTORY
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR, OR SOAP DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE OR WEST
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
YD YARD
YR YEAR
ARCHITECTURAL ABBREVIATIONS GENERAL NOTES
1. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF
THE DRAWINGS TO BE THE FOLLOWING: THE DOCUMENTS (DRAWINGS,
SPECIFICATIONS, ADDENDUM, ETC.) INDICATE THE GENERAL SCOPE OF THE PROJECT
IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSION OF THE BUILDING,
THE MAJOR ARCHITECTURAL ELEMENTS, THE MAJOR STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE
OR DESCRIBE ALL THE WORK REQUIRED FOR FULL PERFORMANCE OF, AND
COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE
GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE
WORK.
2. GENERAL CONTRACTOR IS TO FOLLOW AND OBEY THE LATEST VERSION OF ALL
FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS
WASTE LAWS, ETC. INCLUDING OSHA 101 LIFE SAFETY CODE AND NEC.
3. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
4. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY, FACE OF METAL
STUDS, OR COLUMN CENTERLINE, UNLESS NOTED OTHERWISE.
5. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT
LOCATION. BRING ANY DISCREPANCIES TO THE CONTRACTING OFFICER
REPRESENTATIVE'S (COR) ATTENTION IN WRITING IMMEDIATELY.
WOOD (ROUGH)
PLYWOOD
STEEL OR METAL
ALUMINUM
FIRE SAFING INSULATION
BLANKET, BATT OR LOOSE FILL INSULATION
GRANULAR/GRAVEL FILL
BRICK
CMU
EARTH
CONCRETE
GROUT/GYPSUM BOARD
RIGID/FOAM INSULATION
MATERIAL LEGEND
REFERENCE SYMBOLOGY
DETAIL IDENTIFICATION NUMBER
AREA OF DETAIL
NUMBER OF SHEET ON WHICH
SECITON IS DRAWN
SYMBOL WHERE SECTION IS TAKEN
SCALE AT WHICH SECTION
IS DRAWN
SECTION IDENTIFICATION
NUMBER
SUBTITLE FOR SECTION DRAWNG
SYMBOL WHERE DETAIL IS TAKEN
A101
SIM
SUBTITLE FOR DETAIL DRAWNG
A001
SHEET REFERENCE NUMBER
SHEET SEQUENCE NUMBER
DISCIPLINE CODE NORTH
NORTH ARROW
P5-3
PARTITION TYPE DOOR NUMBER
DOOR REFERENCE NUMBER
ROOM NAME & NUMBER
PARTITION TYPE
NUMBER
ROOM NUMBER
SHEET NOTE
NOTE REFERENCE NUMBER
SYMBOL WHERE ELEVATION IS TAKEN ELEVATION TAG
A101 Name
Elevation
ELEVATION IDENTIFICATION
ELEVATION HEIGHT
1 Ref
R ef
1 Ref
R ef
NUMBER OF SHEET ON
WHICH ELEVATION IS DRAWN
ELEVATION IDENTIFICATION
NUMBER
DETAIL IDENTIFICATION NUMBER
NUMBER OF SHEET ON WHICH DETAIL IS DRAWN
VESTIBULE
ROOM NAME
A001
A001
SECTION
SCALE 1/2" = 1'-0"
NUMBER OF SHEET ON
WHICH SECTION IS DRAWN
A001
DETAIL
SCALE 1/2" = 1'-0"
SCALE AT WHICH DETAIL IS
DRAWN
NUMBER OF SHEET ON
WHICH DETAIL IS DRAWN
A001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural
Design, Inc. and shall not be used for any purpose without prior expressed written consent. The Owner shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.net
FINAL BID
DOCUMENTS
OF02 26
Z:
\V iri di an \P ro je ct s\
\0
D R
AW
IN
G S\
R
EV
IT
\L
O C
AL
F
IL
ES
\5
-2 1-
4_
C
AM
PU
SP
LA
N
_C
EN
TR
AL
_R
_d ro an .rv t
/1 5/
:3
2:
P M
GI002
ARCHITECTURAL - ABBREVIATIONS AND
SYMBOLS
REPLACE ROOFS, VARIOUS
BUILDINGS PHASE II
BATTLE CREEK. MICHIGAN
515-21-104
CAMPUS PLAN
11/16/2021 TWT JMP
S S
URBAN DRIVE
AR
MS
TR
ON
G
RO
AD
AR
MS
TR
ON
G
RO
AD
SHAFTER CIRCLE WEST
DAUNE DEWEY LANE
PAUL LAMBERS TRAIL
SHAFTER CIRCLE NORTH
HE
NR
Y F
OX L
AN
E
HA
MMER
BE
RG LA
NE
DW
IGHT JOHNSON DRIV E
SHAFTER CIRCLE EAST
SHAFTER CIRCLE SOUTH
SHAFTER CIRCLE SOUTH
SHAFTER CIRCLE SOUTH
DICKMAN ROAD
G
G
168144
170159
135 135
BLDG.
BLDG. 6 & 138
LAYDOWN &
DUMPSTER AREA
BLDG.
BLDG. 2 LAYDOWN
& DUMPSTER AREA
BLDG.
BLDG. 5 & 134
DUMPSTER AREA
BLDG.
BLDG. 3
LAYDOWN
AREA
BLDG. 3
DUMPSTER
AREA
BLDG.
BLDG. 5 & 134
LAYDOWN AREA
BLDG. 2 -
AMBULANCE
BAY
MAIN LAYDOWN
AREA
AFFECTED BUILDINGS
BUILDING 02 - AMBULANCE BAY
BUILDING 03
BUILDING 05
BUILDING 06
BUILDING 134
BUILDING 138
CONSTRUCTION INFECTION CONTROL RISK
ASSESSMENT (ICRA) NOTES
WEATHER INFILTRATION, BUILDING DUST, AND INFECTION CONTROL NOTES:
THESE NOTES APPLY TO ALL WORK DESCRIBED IN THESE DRAWINGS AND SPECIFICATIONS AND TO ALL CONTRACTORS AND / OR SUBCONTRACTORS THAT WORK IN, ON , OR AROUND THE BUILDINGS OR THE ADJACENT SITE. FOR ADDITIONAL SCOPE OF WORK DESCRIBED IN DETAIL, SEE THE RESPECTIVE DISCIPLINE
DRAWINGS AND SPECIFICATIONS.
COORDINATE WITH THE BATTLE CREEK VAMC CONTRACTING OFFICER REPRESENTATIVE (COR) TO OBTAIN THE INFECTION CONTROL CONSTRUCTION PERMIT PRIOR TO THE START OF DEMOLITION AND CONSTRUCTION.
1. REFER TO SPECIFICATIONS FOR BATTLE CREEK VAMC INFECTION CONTROL RISK ASSESSMENT (ICRA) TYPICAL
INFECTION CONTROL REQUIREMENTS.
2. USING THE ICRA DIRECTIVE, COORDINATE WITH COR TO DETERMINE THE FOLLOWING PROJECT CONDITIONS:
2.1 TYPE OF CONSTRUCTION PROJECT ACTIVITY
2.2 PATIENT RISK GROUP
2.3 CLASS OF PRECAUTION / LEVEL OF INFECTION CONTROL ACTIVITIES REQUIRED
3. ONCE THE "CLASS OF PRECAUTION" HAS BEEN DETERMINED, COORDINATE WITH THE COR, USING THE LIST OF TYPICAL INFECTION CONTROL ACTIVITIES OUTLINED IN THE ICRA "DESCRIPTION OF REQUIRED INFECTION CONTROL PRECAUTIONS BY CLASS", TO DETERMINE THE SPECIFIC EXTENT AND APPLICATION OF THE REQUIRED INFECTION
CONTROL PRECAUTIONS.
4. IMPLEMENT (PROVIDE, INSTALL, MAINTAIN, AND REMOVE) THE SPECIFIC INFECTION CONTROL PROCEDURES AS
DETERMINED BY COORDINATION WITH COR.
THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK, THEREFORE, PROVIDE, INSTALL, AND MAINTAIN ALL WEATHER INFILTRATION, CONSTRUCTION DUST AND DEBRIS, AND INFECTION CONTROL MEASURES AS REQUIRED BY THE COR. PROVIDE TEMPORARY ROOFING AS NECESSARY THROUGHOUT DEMOLITION AND INSTALLATION OF NEW ROOFING SYSTEM TO MAINTAIN A WATERTIGHT BUILDING ENVELOPE THROUGHOUT THE DURATION OF THE ROOF REPLACEMENT PROJECT. COORDINATE SPECIFIC INFORMATION INCLUDING WORK PHASING, SEQUENCE, AND SCHEDULE WITH THE COR. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
ALL CONSTRUCTION AREAS AND ASSOCIATED WORK AREAS INSIDE AND OUTSIDE THE BUILDINGS SHALL BE KEPT
CLEAN BY THE CONTRACTOR - DAILY.
PROTECT ADJACENT SPACES AND EXISTING EQUIPMENT FROM DEMOLITION DEBRIS AND DAMAGE DURING
CONSTRUCTION.
CONTRACTOR TO ENSURE NO DEMOLITION DEBRIS IS LEFT ON SITE PRIOR TO COMPLETING ALL DEMOLITION
WORK.
ALL CONTRACTORS SHALL BE RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS TO CONTACT THE COR IMMEDIATELY; PRIOR TO THE
END OF THE DAY OF CONSTRUCTION.
OFF HOURS WORK
BUILDING 3 - FLAT ROOF PORTION ONLY
BUILDING 5
BUILDING 134
CONTRACTOR SHALL PERFORM WORK OUTSIDE OF REGULAR
BUSINESS HOURS (M-F, 8AM-5PM) FOR THE FOLLOWING
BUILDINGS (COORDINATE EXACT SCHEDULE WITH COR):
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural
Design, Inc. and shall not be used for any purpose without prior expressed written consent. The Owner shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.net
FINAL BID
DOCUMENTS
OF03 26
Z:
\V iri di an \P ro je ct s\
\0
D R
AW
IN
G S\
R
EV
IT
\L
O C
AL
F
IL
ES
\5
-2 1-
4_
C
AM
PU
SP
LA
N
_C
EN
TR
AL
_R
_d ro an .rv t
/1 5/
:3
2:
P M
GI003
CAMPUS PLAN REPLACE ROOFS, VARIOUS
BUILDINGS PHASE II
BATTLE CREEK. MICHIGAN
515-21-104
CAMPUS PLAN
11/16/2021 TWT JMP
SCALE: 1" = 160'-0"
GI003
CAMPUS PLAN
NORTH
GENERAL PROJECT CONSTRUCTION NOTES
1. THESE NOTES APPLY TO ALL WORK DESCRIBED IN THESE DRAWINGS AND SPECIFICATIONS AND TO ALL
CONTRACTORS AND / OR SUBCONTRACTORS THAT WORK IN, ON, OR AROUND THIS BUILDING OR THE ADJACENT SITE. FOR ADDITIONAL SCOPE OF WORK DESCRIBED IN DETAIL, SEE THE RESPECTIVE BUILDINGS
DRAWINGS AND SPECIFICATIONS.
2. EXISTING SITE AND BUILDING UTILITIES: PRIOR TO THE COMMENCEMENT OF ANY / ALL WORK, VERIFY THE LOCATION AND ENSURE THE OBVIOUS MARKING OF ALL EXISTING UTILITIES AND RELATED EQUIPMENT ON, ABOVE, OR BENEATH THE ADJACENT SITE, AND IN THE BUILDING, WHETHER INDICATED TO REMAIN, TO BE MODIFIED, OR TO BE REMOVED. COORDINATE ALL VERIFICATION AND MARKING WORK WITH THE COR. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
3. SITE AND BUILDING ACCESS AND SECURITY: THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK. THEREFORE, PROVIDE, INSTALL, AND MAINTAIN ALL TEMPORARY MEASURES REQUIRED TO MAINTAIN ACCESS AND SECURITY OF THE EXISTING BUILDING AND THE ADJACENT SITE, AND RELOCATE AS REQUIRED FOR PROJECT PHASING FOR THE DURATION OF THE CONSTRUCTION PROJECT.
COORDINATE SPECIFIC INFORMATION WITH THE COR. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
4. EXISTING SITE AND BUILDING CONDITION: PROVIDE, INSTALL, AND MAINTAIN PROTECTIVE MEASURES TO KEEP THE EXISTING BUILDING AND THE ADJACENT SITE FROM CONSTRUCTION DAMADE DURING ALL PHASES OF THIS WORK. RESTORE ANY PORTION OF THE EXISTING BUILDING OR ADJACENT SITE INADVERTENTLY DAMAGED BY, OR AS A RESULT OF THIS WORK, AT NO ADDITIONAL COST TO THE VA. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION. (THIS INCLUDES INTERIOR AND EXTERIOR SPACES.)
5. TEMPORARY FACILITIES: PROVIDE, INSTALL, AND MAINTAIN ALL REQUIRED TEMPORARY FACILITIES DURING THE CONSTRUCTION PROJECT. RELOCATE TEMPORARY FACILITIES AS REQUIRED FOR PROJECT PHASING.
COORDINATE SPECIFIC INFORMATION WITH THE COR. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
6. WEATHERTIGHT BUILDING CONDITIONS: EXISTING WEATHERTIGHT BUILDING CONDITIONS WILL BE INTERRUPTED DURING THIS PROJECT (I.E. REMOVAL OF PORTIONS OF THE ROOF AND ITS SUPPORTING STRUCTURE). THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK. THEREFORE, PROVIDE, INSTALL, AND MAINTAIN TEMPORARY WEATHERTIGHT CONDITIONS DURING ALL PHASES OF THE
CONSTRUCTION PROJECT. COORDINATE SPECIFIC INFORMATION WITH THE COR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
7. GENERAL DEMOLITION NOTES AND INFORMATION: SEE DISCIPLINE DRAWINGS AND SPECIFICATIONS FOR GENERAL DEMOLITION NOTES AND INFORMATION INCLUDING DISPOSAL AND / OR SALVAGE OF DEMOLISHED MATERIALS. COORDINATE SPECIFIC INFORMATION WITH THE COR. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
8. EXISTING ELECTRICAL POWER SUPPLIES AND EQUIPMENT: THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK. THEREFORE, COORDINATE ALL TEMPORARY AND PERMANENT DISCONNECTING AND RECONNECTING OF EXISTING POWER SUPPLIES AND EQUIPMENT WITH THE COR. SEE ALL
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
9. EXISTING PLUMBING SUPPLY AND DWV SYSTEMS AND EQUIPMENT: THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF WORK. THEREFORE, COORDINATE ALL TEMPORARY AND PERMANENT DISCONNECTING, MODIFICATIONS TO, REROUTING OF, AND RECONNECTING OF EXISTING PLUMBING SUPPLY AND DWV SYSTEMS AND EQUIPMENT WITH THE COR. SEE ALL DRAWINGS AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
10. EXISTING MECHANICAL SYSTEMS AND EQUIPMENT: THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK. THEREFORE, COORDINATE ALL TEMPORARY AND PERMANENT DISCONNECTING AND RECONNECTING OF EXISTING MECHANICAL SYSTEMS AND EQUIPMENT WITH THE COR. SEE ALL DRAWINGS AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. EXISTING FIRE-PROTECTION SYSTEMS AND EQUIPMENT: THE BUILDINGS WILL REMAIN FULLY OCCUPIED DURING ALL PHASES OF THIS WORK. THEREFORE, COORDINATE ALL TEMPORARY AND PERMANENT DISCONNECTING, MODIFICATIONS TO, REROUTING OF, AND RECONNECTING OF EXISTING FIRE-PROTECTION SYSTEMS AND EQUIPMENT WITH THE COR. SEE ALL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
NOTE:
CONTRACTOR IS RESPONSIBLE TO PATCH, REPAIR, AND REPLACE
ANY DAMAGED MATERIAL OR FINISHES, INTERIOR OR EXTERIOR OF
THE BUILDING INCLUDING LANDSCAPED, NOT LANDSCAPED, AND
GRASS AREAS AS A RESULT OF THIS PROJECT. ALL COSTS FOR
PATCH, REPAIR, AND REPLACEMENT IS THE RESPONSIBILITY OF
THE CONTRACTOR. ALL PATCH, REPAIR, AND REPLACEMENT IS TO
MATCH EXISTING ADJACENT MATERIAL IN QUALITY, SIZE, TEXTURE,
COLOR, AND FINISH.
NOTE:
CONTRACTOR TO PROVIDE TEMPORARY TOILETS FOR CREW.
NOTE:
CONTRACTOR SHALL NOT PARK AT JOBSITE OR DRIVE ACROSS
NON-PAVED AREAS OR ON SIDEWALKS. CONTRACTOR SHALL PARK
IN DESIGNATED LOTS ONLY.
NOTE:
CONTRACTOR SHALL PROVIDE OWN STORAGE CONTAINERS AND
TRAILERS. CONTRACTOR SHALL FENCE IN AREA PROVIDED BY VA
DURING CONSTRUCTION AND CONTRACTOR SHALL REMOVE FENCE
AND STORAGE CONTAINERS / TRAILERS IN THEIR ENTIRETY UPON
COMPLETION OF CONSTRUCTION. CONTRACTOR SHALL
COORDINATE EXACT LOCATION FOR STAGING SPACE WITH COR
PRIOR TO THE START OF CONSTRUCTION.
NOTE:
ALL ELECTRICAL AND HVAC DISRUPTIONS SHALL BE COORDINATED
WITH COR.
BATTLE CREEK CAMPUS - ASBESTOS CONTAINING MATERIAL
BUILDING
NOTES:
1. ALL INCLUSIVE REPORT INCLUDED IN SPECIFICATIONS.
2. ALL ASBESTOS CONTAINING MATERIALS SHALL BE TESTED / SAMPLED BY CONTRACTOR PRIOR TO CONSTRUCTION.
3. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
LOCATION MATERIAL
QUANTITY
UNIT OF
MEASURE
MATERIAL DESCRIPTION CONDITION
EXTERIOR 2,500 S.F. GRAY ROOF FLASHING UNDAMAGED
NOTES
1, 2, 3
BUILDING 5
NOTE:
CONTRACTOR RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF
HAZARDOUS MATERIALS. IF SUSPECT ASBESTOS CONTAINING
MATERIALS ARE DISCOVERED, CONTACT THE COR IMMEDIATELY.
4" RD 4" RD
P1
P2
P3
COVERED WALKWAY
(NO WORK)
BUILDING 2 MAIN (NO WORK)
COVERED WALKWAY
(NO WORK)
BUILDING 2 MAIN (NO WORK)
COVERED WALKWAY
(NO WORK)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural
Design, Inc. and shall not be used for any purpose without prior expressed written consent. The Owner shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.net
FINAL BID
DOCUMENTS
OF04 26
Z:
\V iri di an \P ro je ct s\
\0
D R
AW
IN
G S\
R
EV
IT
\L
O C
AL
F
IL
ES
\5
-2 1-
4_
B0 2_
C
EN
TR
AL
_R
_d ro an .rv t
/1 5/
:1
0:
P M
02.AD200
BUILDING 02 - DEMOLITION ROOF PLAN REPLACE ROOFS, VARIOUS
BUILDINGS PHASE II
BATTLE CREEK, MICHIGAN
515-21-104
BUILDING 02
11/16/2021 TWT JMP
SCALE: 3/8" = 1'-0"
02.AD200
BUILDING 02 - DEMOLITION ROOF PLAN
GENERAL DEMOLITION NOTES
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND / OR
SUBCONTRACTORS THAT WORK WITHIN THE BUILDING.
1. ALL MATERIALS INDICATED AS DASHED ARE TO BE REMOVED. THIS INCLUDES ALL FINISHES
AND MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE INTENDED SCOPE.
CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK BETWEEN ALL TRADES.
2. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. THESE DEMOLITION SHEETS SHALL SERVE TO AID THE CONTRACTOR IN
THE EVALUATION OF THE EXTENT OF DEMOLITION: BUT SHALL NOT BE HELD TO BE ALL
INCLUSIVE.
3. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL, TO ENSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. IF THE INSPECTION INDICATES THAT THE STRUCTURAL INTEGRITY MAY BE COMPROMISED, NOTIFY THE
ARCHITECT / ENGINEER IMMEDIATELY.
4. ALL CONSTRUCTION AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN BY THE
CONTRACTOR – DAILY.
5. PROTECT FROM DEMOLITION DEBRIS AND EQUIPMENT, ALL EXISTING TREES.
6. CONTRACTOR TO ENSURE NO DEMOLITION DEBRIS IS LEFT ON SITE (WOODS, DRIVEWAY, OR
COUNTY ROADS) PRIOR TO COMPLETING ALL DEMOLITION WORK.
7. CONTRACTOR RESPONSIBLE TO REGRADE ALL RUTS, DEPRESSIONS, AND DAMAGED AREAS
AROUND BUILDING. REGRADE, ADD TOPSOIL, AND RESEED GRASS TO MATCH EXISTING.
NOTE:
NOT ALL KEYNOTES ARE USED ON EVERY SHEET. OTHER NOTE NOT
USED ON THIS SHEET MAY OCCUR ON OTHER SHEETS.
NORTH
DEMO PLAN CONSTRUCTION NOTES
THROUGHOUT ENTIRE LIMITS / EXTENTS OF EXISTING ROOF SYSTEMS, REMOVE EXISTING FLAT ROOF ASSEMBLIES AND WALKWAY PADS INCLUDING: MEMBRANE, WOOD-FIBER, EXTRUDED POLYSTYRENE (XPS) RIGID INSULATION COMPOSITE, FLASHINGS, FASTENERS, ACCESSORIES, AND VAPOR BARRIER IN THEIR ENTIRETY DOWN TO THE EXISTING ROOF DECK SYSTEM AND PREPARE FOR NEW ROOFING SYSTEM.
EXISTING ROOF DRAIN TO REMAIN. TEMPORARILY DISCONNECT AND REMOVE ROOF DRAIN ASSEMBLY IN ITS ENTIRETY FROM EXISTING ROOF DECK SYSTEM AND EXISTING STORM PIPING. EXISTING CAST-IRON
DOME TO BE SALVAGED FOR REINSTALLATION.
3 THROUGHOUT ENTIRE LIMITS / EXTENTS OF EXISTING ROOF SYSTEM, REMOVE EXISTING SLOPED ROOF ASSEMBLIES INCLUDING: SHINGLES, FELT, FLASHINGS, FASTENERS, AND ACCESSORIES IN THEIR ENTIRETY DOWN TO THE EXISTING ROOF DECK SYSTEM. REMOVE ANY AREAS OF DAMAGED ROOF DECK
SYSTEM AND PREPARE FOR NEW ROOFING SYSTEM.
4 REMOVE EXISTING ROOF EDGE / FASCIA SYSTEM (S), AND ASSOCIATED WOOD NAILERS, FASTENERS, AND ACCESSORIES IN THEIR ENTIRETY. PREPARE REMAINING SUBSTRATE FOR INSTALLATION OF THE NEW INSULATED ROOF SYSTEM, INCLUDING NEW WOOD NAILERS AND ACCESSORIES WHERE INDICATED.
5 EXISTING PLUMBING VTR (VENT THROUGH ROOF) TO REMAIN. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND RELATED ACCESSORIES. PREPARE VTR TO
RECEIVE NEW ROOF FLASHING.
6 EXISTING MECHANICAL FLUE / HEAT VENT TO REMAIN. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND RELATED ACCESSORIES. PREPARE FLUE TO RECEIVE NEW ROOF
FLASHING.
7 REMOVE EXISTING MECHANICAL EXHAUST FAN AND CURB IN ITS ENTIRETY, DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN CONCRETE ROOF DECK FROM WEATHER INFILTRATION AND FOR SAFETY
OF PERSONNEL AS REQUIRED.
8 EXISTING MECHANICAL EXHAUST FAN / RELIEF VENT / GRAVITY VENT AND ROOF CURB TO REMAIN.
TEMPORARILY DISCONNECT FROM ROOF CURB, MECHANICAL AND ELECTRICAL SYSTEMS, SALVAGE, REMOVE, AND STAGE FOR REINSTALLATION AS REQUIRED FOR INSTALLATION OF NEW INSULATED ROOF SYSTEM. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND
RELATED ACCESSORIES. PREPARE ROOF CURB TO RECEIVE NEW ROOF FLASHING.
9 REMOVE EXISTING GUTTER SYSTEM, DOWNSPOUTS, AND ACCESSORIES IN THEIR ENTIRETY. REMOVE
MEMBRANE FLASHINGS AND TERMINATIONS.
10 EXISTING STEEL ACCESS LADDER AND CAGE TO ROOF TO REMAIN. REMOVE AS NEEDED FOR NEW ROOF
INSTALLATION.
11 ROOF CORE SAMPLE TAKEN OCTOBER 28TH, 2020. REFER TO SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
12 DISCONNECT AND REMOVE EXISTING LIGHTNING PROTECTION SYSTEM DOWN TO GROUNDING RODS.
REMOVE ALL CONDUCTORS, AIR TERMINALS, MOUNTING TABS, AND ALL APPURTENANCES IN THEIR
ENTIRETY. SEE NOTE 6 ON NEW CONSTRUCTION DRAWINGS FOR ADDITIONAL WORK.
13 REMOVE EXISTING PARAPET COPING, EXPANSION JOINT, AND ASSOCIATED WOOD NAILERS, FASTENERS, AND ACCESSORIES, IN THEIR ENTIRETY. PREPARE REMAINING SUBSTRATE FOR INSTALLATION OF NEW INSULATED ROOF SYSTEM, INCLUDING NEW WOOD NAILERS, EXPANSION JOINTS, AND ACCESSORIES
WHERE INDICATED.
14 EXISTING MECHANICAL UNIT AND ROOF CURB TO REMAIN. TEMPORARILY DISCONNECT FROM ROOF CURB, MECHANICAL AND ELECTRICAL SYSTEMS, SALVAGE, REMOVE AND STAGE FOR REINSTALLATION AS REQUIRED FOR INSTALLATION OF NEW INSULATED ROOF SYSTEM. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND RELATED ACCESSORIES. PREPARE ROOF CURB
TO RECEIVE NEW ROOF FLASHING.
15 REMOVE EXISTING ROOF PAVERS IN THEIR ENTIRETY.
16 REMOVE AND SALVAGE EXISTING ROOF STEP CROSS OVER LADDER FOR REINSTALLATION. PROTECT
FROM DEMOLITION AND CONSTRUCTION DAMAGE.
17 REMOVE AND SALVAGE EXISTING ROOF GUARDRAIL SAFETY RAILING FOR REINSTALLATION. PROTECT
FROM DEMOLITION AND CONSTRUCTION DAMAGE.
18 REMOVE EXISTING ELECTRICAL VTR (VENT THROUGH ROOF), ROOF FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN METAL
ROOF DECK FROM WEATHER INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
19 EXISTING ELECTRICAL BOX, CONDUIT, AND ROOF BLOCKING TO REMAIN. TEMPORARILY DISCONNECT, SALVAGE, REMOVE, AND STAGE FOR REINSTALLATION AS REQUIRED FOR INSTALLATION OF NEW INSULATED ROOF SYSTEM. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND RELATED ACCESSORIES. PREPARE ROOF CURB TO RECEIVE NEW ROOF FLASHING.
20 EXISTING COPPER FLASHING SYSTEM TO REMAIN. PROTECT FROM DEMOLITION AND CONSTRUCTION
DAMAGE.
21 EXISTING STEEL ACCESS LADDER TO ROOF TO REMAIN. REMOVE EXISTING LADDER GUARD. REMOVE
LADDER AS NEEDED FOR NEW ROOF INSTALLATION.
22 REMOVE EXISTING WALL FLASHING SYSTEM (S), ASSOCIATED FASTENERS, AND ACCESSORIES IN THEIR ENTIRETY. PREPARE REMAINING SUBSTRATE FOR INSTALLATION OF THE NEW INSULATED ROOF SYSTEM, INCLUDING FASTENERS AND ACCESSORIES WHERE INDICATED.
23 EXISTING PARAPET WALL AND CONCRETE COPING TO REMAIN. REMOVE LOOSE SPALDING PRE-CAST CONCRETE COPING PIECES ON PARAPET WALL. REMOVE DIRT, DUST, AND DEBRIS AND PREPARE REMAINING SUBSTRATE FOR INSTALLATION OF NEW 2X KDAT WOOD BLOCKING AND ALUMINUM COPING SYSTEM.
24 REMOVE EXISTING ROOF CURB, FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN CORRUGATED METAL ROOF DECK FROM WEATHER
INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
DEMO PLAN CONSTRUCTION NOTES CONT.
25 REMOVE EXISTING ROOF CURB, FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN WOOD ROOF DECK FROM WEATHER INFILTRATION
AND FOR SAFETY OF PERSONNEL AS REQUIRED.
26 REMOVE EXISTING PLUMBING VTR (VENT THROUGH ROOF), FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN CONCRETE ROOF DECK
FROM WEATHER INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
27 REMOVE EXISTING ROOF HATCH, FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO
DECK. TEMPORARILY PROTECT REMAINING OPENING IN CONCRETE ROOF DECK FROM WEATHER
INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
28 REMOVE EXISTING CONCRETE BLOCK IN ITS ENTIRETY.
29 EXISTING ACCESS DOOR TO REMAIN. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE.
30 EXISTING MECHANICAL EXHAUST FAN / RELIEF VENT / GRAVITY VENT TO REMAIN. TEMPORARILY DISCONNECT FROM MECHANICAL AND ELECTRICAL SYSTEMS, SALVAGE, REMOVE, AND STAGE FOR REINSTALLATION AS REQUIRED FOR INSTALLATION OF NEW ROOF SYSTEM. PROTECT FROM DEMOLITION AND CONSTRUCTION DAMAGE. REMOVE ROOF FLASHING AND RELATED ACCESSORIES. PREPARE ROOF TO RECEIVE NEW FLASHING.
31 REMOVE EXISTING ROOF HATCH, FLASHING, AND RELATED ACCESSORIES IN THEIR ENTIRETY DOWN TO DECK. TEMPORARILY PROTECT REMAINING OPENING IN CORRUGATED METAL ROOF DECK FROM WEATHER
INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
32 REMOVE EXISTING MECHANICAL EXHAUST FAN AND CURB IN ITS ENTIRETY, DOWN TO DECK. TEMPORARILY DISCONNECT ELECTRICAL AND PROTECT REMAINING OPENING IN CORRUGATED METAL ROOF DECK FROM
WEATHER INFILTRATION AND FOR SAFETY OF PERSONNEL AS REQUIRED.
33 THROUGHOUT ENTIRE LIMITS / EXTENTS OF EXISTING ROOF SYSTEM, REMOVE EXISTING SLOPED
METAL ROOF OVERHANG ASSEMBLIES INCLUDING: METAL, FELT, FLASHINGS, FASTENERS, AND
ACCESSORIES IN THEIR ENTIRETY DOWN TO THE EXISTING ROOF DECK SYSTEM. REMOVE ANY AREAS
OF DAMAGED ROOF DECK SYSTEM AND PREPARE FOR NEW ROOFING SYSTEM.
34 EXISTING HVAC SUPPORTS AND HANDRAILS TO REMAIN. PROTECT FROM DEMOLITION AND
CONSTRUCTION DAMAGE.
35 EXISTING ALUMINUM ACCESS LADDER AND CAGE TO ROOF TO REMAIN. REMOVE AS NEEDED FOR
NEW ROOF INSTALLATION.
36 REMOVE EXISTING METAL SCUPPER BOX, DOWNSPOUT, AND ACCESSORIES IN THEIR ENTIRETY.
REMOVE MEMBRANE FLASHINGS AND TERMINATIONS.
37 EXISTING MECHANICAL FLUE / HEAT VENT TO REMAIN. REMOVE VENT HOOD IN ITS ENTIRETY. REMOVE ROOF FLASHINGS AND RELATED ACCESSORIES. PREPARE FLUE TO RECEIVE NEW ROOF FLASHINGS
AND VENT HOOD.
38 REMOVE EXISTING COPPER WALL FLASHING SYSTEM (S), ASSOCIATED FASTENERS, AND
ACCESSORIES IN THEIR ENTIRETY. PREPARE SUBSTRATE FOR INSTALLATION OF THE NEW INSULATED
ROOF SYSTEM, INCLUDING FASTENERS AND ACCESSORIES WHERE INDICATED.
39 REMOVE BROKEN OR DAMAGED BRICK.
40 REMOVE AREAS OF DAMAGED WOOD FASCIA AND SOFFIT.
41 REMOVE EXISTING VINYL SIDING AND BUILDING WRAP FROM GABLE ENDS IN ITS ENTIRETY. PREPARE
SUBSTRATE TO RECEIVE NEW BUILDING WRAP AND SIDING.
42 ABANDONED PLUMBING VENT. REMOVE PIPING AND PATCH HOLE IN ROOF DECK TO MATCH EXISTING.
NOT TO SCALE
ROOF PLAN
BUILDING 02 KEY PLAN
CONSTRUCTION
LIMITS
NOT IN
SCOPE OF
WORK
NORTH
NOTE:
CONTRACTOR IS RESPONSIBLE TO PATCH, REPAIR, AND REPLACE
ANY DAMAGED MATERIAL OR FINISHES, INTERIOR OR EXTERIOR OF
THE BUILDING INCLUDING LANDSCAPED, NOT LANDSCAPED, AND
GRASS AREAS AS A RESULT OF THIS PROJECT. ALL COSTS FOR
PATCH, REPAIR, AND REPLACEMENT IS THE RESPONSIBILITY OF
THE CONTRACTOR. ALL PATCH, REPAIR, AND REPLACEMENT IS TO
MATCH EXISTING ADJACENT MATERIAL IN QUALITY, SIZE, TEXTURE,
COLOR, AND FINISH.
SCALE: NTS
P1 - PHOTO 1
SCALE: NTS
P2 - PHOTO 2
SCALE: NTS
P3 - PHOTO 3
NOTE:
CONTRACTOR RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF
SUSPECT HAZARDOUS MATERIALS. IF SUSPECT ASBESTOS
CONTAINING MATERIALS ARE DISCOVERED, CONTACT THE COR
IMMEDIATELY.
4" RD 4" RD
2 2
02.AS500
02.AS500
02.AS500
______________3
02.AS500
02.AS500
¼ " S
LO
PE
T O
D
RA
IN
¼ " S
LO
PE
T O
D
RA
IN
¼" SLOPE TO
DRAIN ¼" SLOPE TO DRAIN
¼" SLOPE TO DRAIN
¼" S
LO
PE
TO
DRA
IN
IN
SU
LA
TI
O N
RI
DG
E
VA
LL
EY
VALLEY
VALLEY VALLEY
VALLEY
VA
LL
EY
VALLEYVALLEY
COVERED WALKWAY
(NO WORK)
BUILDING 2 MAIN (NO WORK)
COVERED WALKWAY
(NO WORK)
BUILDING 2 MAIN (NO WORK)
COVERED WALKWAY
(NO WORK)
COVERED WALKWAY
(NO WORK)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural
Design, Inc. and shall not be used for any purpose without prior expressed written consent. The Owner shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.net
FINAL BID
DOCUMENTS
OF05 26
Z:
\V iri di an \P ro je ct s\
\0
D R
AW
IN
G S\
R
EV
IT
\L
O C
AL
F
IL
ES
\5
-2 1-
4_
B0 2_
C
EN
TR
AL
_R
_d ro an .rv t
/1 5/
:1
0:
P M
02.AS200
BUILDING 02 - ROOF PLAN REPLACE ROOFS, VARIOUS
BUILDINGS PHASE II
BATTLE CREEK, MICHIGAN
515-21-104
BUILDING 02
11/16/2021 TWT JMP
SCALE: 3/8" = 1'-0"
02.AS200
BUILDING 02 - ROOF PLAN
NOTE:
NOT ALL KEYNOTES ARE USED ON EVERY SHEET. OTHER NOTE NOT
USED ON THIS SHEET MAY OCCUR ON OTHER SHEETS.
NORTH
GENERAL CONSTRUCTION NOTES
1. DIMENSIONS ARE FROM CORNER TO CORNER OF OPENING, OR TO FACE OF WALL UNLESS
NOTED OTHERWISE.
2. CONTRACTOR TO COORDINATE ALL WORK BETWEEN TRADES, INCLUDING BETWEEN FINISH
CONTRACTOR, ELECTRICAL, AND MECHANICAL.
3. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL
PRODUCTS PER MANUFACTURER’S WRITTEN INSTRUCTIONS.
4. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR ABILITIES
AT THE END OF EACH WORK DAY.
5. ALL CONTRACTORS ARE RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING THE
CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS TO CONTACT
THE OWNER IMMEDIATELY PRIOR TO THE END OF THE DAY OF CONSTRUCTION.
PLAN CONSTRUCTION NOTES
THROUGHOUT THE ENTIRE LIMITS / EXTENTS OF ROOF, PREPARE ALL EXPOSED CORRUGATED STEEL ROOF DECK TO RECEIVE NEW WORK AS OUTLINED HEREIN. PROVIDE AND INSTALL ALL COMPONENTS OF
NEW R-20 MIN. (AVERAGE) ROOF ASSEMBLY IN THEIR ENTIRETY.
PROVIDE AND INSTALL NEW REPLACEMENT ROOF DRAIN AND RELATED ACCESSORIES IN THEIR ENTIRETY AND CONNECT TO EXISTING STORM PIPING. INSULATE UNDERSIDE OF DRAIN BODY, NEW PIPING, AND
CONNECTION. REINSTALL SALVAGED CAST-IRON DOME.
EXISTING PLUMBING VTR (VENT THROUGH ROOF). PROVIDE AND INSTALL NEW ROOF FLASHING AND RELATED ACCESSORIES IN THEIR ENTIRETY. ALL VENT PIPING TO EXTEND 8" MIN. ABOVE NEW ROOFING
SYSTEM.
EXISTING MECHANICAL FLUE / HEATED VENT. PROVIDE AND INSTALL NEW ROOF FLASHING AND RELATED ACCESSORIES IN THEIR ENTIRETY. ALL VENT PIPING TO EXTEND 8" MIN. ABOVE NEW ROOFING SYSTEM.
PROVIDE AND INSTALL NEW ALUMINUM PARAPET COPING SYSTEM(S), AND ASSOCIATED WOOD NAILERS, FASTENERS, AND ACCESSORIES IN THEIR ENTIRETY.
PROVIDE A NEW CLASS I LIGHTNING PROTECTION SYSTEM AS SPECIFIED IN SECTION 26 41 00.6
PROVIDE AND INSTALL NEW ROOF SYSTEM FLASHINGS, FASTENERS, AND ACCESSORIES IN THEIR
ENTIRETY, TO FLASH NEW ROOF SYSTEM.
PROVIDE AND INSTALL NEW ROOF DECK PATCH (1/4" THICK STEEL PLATE) AS OUTLINED HEREIN TO INFILL EXISTING OPENING IN ROOF DECK. INSTALL NEW ROOF DECK PATCH INFILL FLUSH WITH ADJACENT
EXISTING CONCRETE ROOF DECK TO REMAIN.
REINSTALL EXISTING MECHANICAL EXHAUST FAN / RELIEF VENT / GRAVITY VENT ON EXISTING ROOF CURB. PROVIDE AND INSTALL NEW ROOF FLASHING AND RELATED ACCESSORIES IN THEIR ENTIRETY. ALL ROOF CURBS AND FLASHING TO EXTEND 8" MIN. ABOVE NEW ROOFING SYSTEM. PROVIDE AND INSTALL
2X KDAT WOOD BLOCKING AS REQUIRED TO OBTAIN MINIMUM FLASHING HEIGHT.
REINSTALL EXISTING MECHANICAL UNIT ON EXISTING ROOF CURB. PROVIDE AND INSTALL NEW ROOF FLASHING AND RELATED ACCESSORIES IN THEIR ENTIRETY. ALL ROOF CURBS AND FLASHING TO EXTEND 8" MIN. ABOVE NEW ROOFING SYSTEM. PROVIDE AND INSTALL NEW 2X WOOD BLOCKING AS REQUIRED
TO OBTAIN MINIMUM FLASHING HEIGHT.
EXISTING STEEL ACCESS LADDER AND CAGE TO BE REINSTALLED AS NECESSARY AND MODIFIED AS NEEDED TO ACCOMMODATE NEW ROOFING SYSTEM. PREP, PRIME, AND PAINT ACCESS LADDER AND CAGE.
PAINT ONE COAT PRIMER; TWO COATS, BLACK.
THROUGHOUT ENTIRE LIMITS / EXTENTS OF ROOF SYSTEM, PREPARE ALL EXPOSED ROOF DECK TO RECEIVE NEW WORK AS OUTLINED HEREIN. PROVIDE AND INSTALL ALL COMPONENTS OF NEW SHINGLED ROOF ASSEMBLY INCLUDING SHINGLES, SYNTHETIC FELT, FLASHINGS, FASTENERS, AND ACCESSORIES
IN THEIR ENTIRETY. REPAIR AREAS OF DAMAGED ROOF DECK SYSTEM TO MATCH EXISTING.
EXISTING ROOF STEP CROSS OVER LADDER TO BE REINSTALLED. PREP, PRIME, AND PAINT LADDERS.
PAINT ONE COAT PRIMER; TWO COATS, BLACK.
EXISTING ROOF GUARDRAIL SAFETY RAILING TO BE MODIFIED AND REINSTALLED. PREP, PRIME, AND
PAINT RAILS. PAINT ONE COAT PRIMER; TWO COATS, BLACK.
PROVIDE AND INSTALL NEW STAINLESS STEEL FLASHING, SLOPED AT ½" PER FOOT ON UPHILL SIDE OF
EQUIPMENT.
REINSTALL EXISTING ELECTRICAL BOX AND CONDUIT ON EXISTING ROOF BLOCKING. PROVIDE AND INSTALL NEW ROOF FLASHING AND RELATED ACCESSORIES IN THEIR ENTIRETY. EXTEND ELECTRICAL AS
NEEDED TO ACCOMMODATE NEW ROOFING SYSTEM.
EXISTING COPPER FLASHING SYSTEM TO REMAIN. PROTECT FROM DEMOLITION AND CONSTRUCTION
DAMAGE. FIX DAMAGED COPPER.
PROVIDE AND INSTALL ALL COMPONENTS OF NEW SHINGLED SMARTVENT ROOF VENTILATION SYSTEM IN THEIR ENTIRETY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. SEE DETAIL 01 / 03.AS501
FOR ADDITIONAL INFORMATION.
PROVIDE AND INSTALL NEW ALUMINUM ROOF EDGE / FASCIA SYSTEM(S), AND ASSOCIATED WOOD
NAILERS, FASTENERS AND ACCESSORIES IN THEIR ENTIRETY.
THROUGHOUT THE ENTIRE LIMITS / EXTENTS OF ROOF, PREPARE ALL EXPOSED CONCRETE ROOF DECK TO RECEIVE NEW WORK AS OUTLINED HEREIN. PROVIDE AND INSTALL ALL COMPONENTS OF NEW R-20
MIN. (AVERAGE) ROOF ASSEMBLY IN THEIR ENTIRETY.
PROVIDE AND INSTALL NEW RIGID INSULATION CRICKET, SLOPED AT ½" PER FOOT ON UPHILL SIDE OF
EQUIPMENT CURBS.
PROVIDE AND INSTALL NEW RUBBER ROOF PAVERS. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.23
PROVIDE…
This is the start of the file's text. The full file is on GovTribe.