05-A.122 - RCP -SECOND FLOOR.pdf
PDF 329 KB Posted
- Attached to
- Z1DA--Upgrade and Expand Security Camera's 515-18-201 Federal contract opportunity
- Solicitation number
- 36C25021B0033
About this file
This document provides details of a federal contract opportunity for upgrading and expanding security cameras at the Battle Creek VA Medical Center in Battle Creek, Michigan. The solicitation will require contractors to remove all existing cameras and wiring and install new IP cameras using CAT6A and fiber optic cable. Additional requirements include installing new patch panels, network switches, and NVRs to support the new camera system and minimize bandwidth usage. New software must also be provided to retrieve and monitor network recordings. The contract award is for a firm fixed price with a performance period of 180 days. Interested parties should monitor the beta.SAM.gov website on or about May 30, 2020 for solicitation documents. The estimated value of the construction project is between $1,000,000 and $5,000,000.
View the file
Other files for this federal contract opportunity
Show all 47
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8' - 6"
8' - 0"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1" 9
9' - 0"9' - 0"
9' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
9' - 1"
8' - 6"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
9' - 1"
8' - 1"
9' - 2"
NOT FOR CONSTRUCTION
RDC/ JOHN POE ARCHITECTS
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
2/20/2020 8:04:31 AM
BIM Master Record Drawings
02.21.2020
RCP -SECOND FLOOR
05-A.122
506-17-601
Battle Creek, Michigan (515)
VA Station No:
Randy Crandal
Record Drawing 18007.00
Scale: 1/8" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN
Revisions Date
KEY PLAN
| Sheets |
| 05-A.100 - BASEMENT FLOOR PLAN |
| 05-A.101 - FIRST FLOOR PLAN |
| 05-A.102 - SECOND FLOOR PLAN |
| 05-A.120 - RCP - BASEMENT |
| 05-A.121 - RCP - FIRST FLOOR |
| 05-A.122 - RCP -SECOND FLOOR |
| 05-A.200 - NORTH & SOUTH ELEVATIONS |
| 05-A.201 - EAST & WEST ELEVATIONS |
File details come from the government source that posted it. Updated .