2. Photographs of Existing Conditions (Taken in March 2018).pdf
PDF 3 MB Posted
- Solicitation number
- 36C25020B0020
About this file
This document includes a pre-solicitation notice and project description for a federal contract opportunity, as well as photographs documenting existing conditions at the project site.
The Department of Veterans Affairs Network Contracting Office 10 is seeking bids for project 541-18-103 to replace the roof overhangs at the CARES Tower located at the Louis Stokes Cleveland VA Medical Center. The contractor will be responsible for all preparation, demolition, construction and coordination required to complete the roof replacement. The project is set aside solely for service-disabled veteran-owned small businesses and has a budget between $1 million and $5 million. Bids are due approximately 30 days after solicitation documents are posted to SAM.gov on February 21, 2020. The selected contractor must complete all work within 290 calendar days of receiving the notice to proceed and perform a minimum of 15% of construction work. The project is subject to bonding requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25020B0020 0005.docx | DOCX document | |
| 36C25020B0020 0004.docx | DOCX document | |
| 1a. Response to RFI #12 Record Drawings.pdf | ||
| 1. REVISED RFI Tracker with VA Responses (Updated as of 20200601).docx | DOCX document | |
| 3. Revised Bid Items for Project 541-18-103.docx | DOCX document | |
| 36C25020B0020-0003000.docx | DOCX document | |
| 36C25020B0020-0003001.pdf | ||
| 36C25020B0020-0002009.pdf | ||
| 36C25020B0020-0002012.pdf | ||
| 36C25020B0020-0002008.docx | DOCX document | |
| 36C25020B0020-0002010.pdf | ||
| 36C25020B0020-0002011.pdf | ||
| 36C25020B0020-0001000.docx | DOCX document | |
| 36C25020B0020-002.pdf | ||
| 36C25020B0020-005.docx | DOCX document | |
| 36C25020B0020-003.pdf | ||
| 36C25020B0020-001.docx | DOCX document | |
| 36C25020B0020-004.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
crogers Oval crogers Oval crogers Oval crogers Oval crogers Oval crogers Oval crogers Oval crogers Text Box
CORE 1
crogers Text Box
CORE 2
crogers Text Box
CORE 3
crogers Text Box
CORE 4
crogers Text Box
CORE 5
crogers Text Box
CORE 6
crogers Text Box
CORE 7
crogers Text Box
ROOF 1
crogers Text Box
ROOF 2
crogers Text Box
ROOF 3
crogers Line crogers Line crogers Line crogers Line crogers Line crogers Line crogers Line crogers Typewritten Text Appendix B crogers Text Box Core Cut Locations Roofs 1, 2 & 3
Text Box
ROOF 4
crogers Text Box
SPIKE TEST
crogers Text Box
CORE 8
crogers Oval crogers Oval crogers Line crogers Line crogers Typewritten Text Appendix B crogers Text Box
Roof 4
Oval crogers Text Box
PLAZA
crogers Text Box
PAVER & INSULATION REMOVED
crogers Line crogers Typewritten Text Appendix B crogers Text Box
Plaza
Appendix A
EXISTING CONDITIONS PHOTOS
Roof Area 1: Elevator Penthouse:
Overview of Roof area 1
Core 1: Approx. 6.5” depth. Concrete deck, Insulation wet
Core 2: Approx. 2.5” depth. Concrete deck, Insulation wet
Roof Area 2: Penthouse:
Overview of Roof area 2
Core 3 at flashing: Approx. 5” depth.
Metal deck, Insulation with densdeck cover board, Insulation dry.
Core 4: Approx. 3” depth. Metal deck. Core was cut at bullet hole, Insulation with densdeck cover board, Insulation wet
Roof Area 2: Penthouse:
Roof Area 3: 6 th Floor
Core 5: Approx. 8” depth. Metal deck, Insulation with densdeck cover board, Insulation dry
Core 6: Concrete deck, Insulation wet
A metal leg was present that may have been present to close a deck to wall gap.
Core 7: Approx. 3.5” depth. Concrete deck, Insulation wet
Roof Area 3: 6
Overview of area
Open seam, wet insulation and wind damage
Evidence of past wind damage.
Roof Area 3: 6
Roof Area 4: 2 nd
Elongated cut made to core 7: no vapor retarder.
Spike: Approx. 2.25” depth. Concrete deck, Insulation wet
Core 8: Approx. 6” depth, 7” to top of wood sitting on steel. Concrete deck, Insulation wet
Roof Area 4: 2 nd
Wind damage evident
Overview of roof area
Through wall flashing and weeps visible, low flashing heights.
Roof Area: Plaza Deck
Paver and insulation removed, did not cut through drainage mat.
Overview of Plaza Deck
Overview of roof area 6: West ledge.
| CARES Roof Report, Legend for existing condition photographs, Mar 2018 |
| CARES Roof Report, Existing condition photographs, Mar 2018 |