36C25019B0041-003.pdf
PDF 15 MB Posted
- Solicitation number
- 36C25019B0041
About this file
36C25019B0041 Part 1 - Drawings - Pharmacy USP (541-19-103).pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019B0041-0004000.docx | DOCX document | |
| 36C25019B0041-0003001.pdf | ||
| 36C25019B0041-0003005.pdf | ||
| 36C25019B0041-0003000.docx | DOCX document | |
| 36C25019B0041-0003003.pdf | ||
| 36C25019B0041-0003002.pdf | ||
| 36C25019B0041-0003004.pdf | ||
| 36C25019B0041-0003006.pdf | ||
| 36C25019B0041-0002000.docx | DOCX document | |
| 36C25019B0041-0002001.pdf | ||
| 36C25019B0041-0001000.docx | DOCX document | |
| 36C25019B0041-006.pdf | ||
| 36C25019B0041-004.pdf | ||
| 36C25019B0041-002.pdf | ||
| 36C25019B0041-007.pdf | ||
| 36C25019B0041-005.pdf | ||
| 36C25019B0041-001.docx | DOCX document | |
| 36C25019B0041-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project Number
Drawing Number o n e-ei g h th in ch o n e fo o t o n e-q u a rt er in ch o n e fo o t th re e-e ig h th s in c h o n e fo o t o n e-h a lf in c h o n e fo o t th re e-q u a rt er s in ch o n e fo o t o n e in c h o n e fo o t o n e a n d o n e-h a lf in ch es o n e fo o t th re e in ch es o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SPRINKLERED
ARCHITECT:CONSULTANTS:
Office of Construction and Facilities Management
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
1468 WEST 9TH STREET #400 CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
E T
G
DE
I
RE
T
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
A
TE
I
T C
J.
O
O
FO
H
VETERANS AFFAIRS MEDICAL CENTER
RENOVATE PHARMACY TO COMPLY WITH
USP DIRECTIVES
5.30.19
TITLE SHEET & DRAWING INDEX
GI-1
541-19-103
10701 EAST BLVD. CLEVELAND, OHIO
CJK DAK
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER - WADE PARK
RENOVATE PHARMACY TO COMPLY WITH USP DIRECTIVES
10701 EAST BLVD. CLEVELAND, OH 44106
PROJECT NO. 541-19-103
Cleveland Veterans Affairs Medical Center
INPATIENT
PHARMACY SCOPE
OF WORK
OUTPATIENT
PHARMACY SCOPE
OF WORK
2ND FLOOR
MODULE J
ONCOLOGY CLINIC
SCOPE OF WORK
BASEMENT LEVEL
NORTH
PARTIAL 2ND FLOOR
NORTH
CODE INFORMATION:
I. PROJECT LOCATION: CLEVELAND VETERANS AFFAIRS MEDICAL CENTER
10701 EAST BLVD.
CLEVELAND, OHIO
II. DESCRIPTION & USER GROUP CLASSIFICATION OF BUILDING
A. NATURE OF PROJECT: INTERIOR RENOVATIONS OF EXISTING BASEMENT LEVEL INPATIENT &
OUTPATIENT PHARMACY
DEPARTMENTS AND 2ND FLOOR MODULE J ONCOLOGY CLINIC
B. DESIGN CODES: 2015 NFPA LIFE SAFETY CODE 101, IBC 2015
USP 795 - PHARMACEUTICAL COMPOUNDING - NON-STERILE PREPARATIONS
USP 797 - PHARMACEUTICAL COMPOUNDING - STERILE PREPARATIONS
USP 800 - HAZARDOUS DRUGS - HANDLING IN HEALTHCARE SETTINGS
C. USE GROUP: I-2 HEALTH CARE - NO CHANGE PROPOSED
D. CONSTRUCTION TYPE: TYPE I-332, IB - NON-COMBUSTIBLE, PROTECTED
FIRE RATED CONSTRUCTION (LSC A.8.2.1.1)
EXTERIOR BEARING WALLS 3 HRS
INTERIOR BEARING WALLS 3 HRS
STRUCTURAL COLUMNS 3 HRS (SUPPORTING > 1 FLOOR)
2 HRS (SUPPORTING 1 FLOOR ONLY)
2 HRS (SUPPORTING ROOF ONLY)
BEAMS, GIRDERS, TRUSSES 3 HRS (SUPPORTING > 1 FLOOR, COLS., OR BEARING WALLS)
FLOOR-CEILING ASSEMBLIES 2 HRS
ROOF-CEILING ASSEMBLIES 1-1/2 HRS
INTERIOR NON-BEARING WALLS 0 HRS
EXTERIOR NON-BEARING WALLS 0 HRS
WALL ASSEMBLIES
EXIT ACCESS CORRIDOR WALLS0 HR SMOKE PARTITIONS
E. PROJECT AREA: INPATIENT PHARMACY: 6,818 SF
OUTPATIENT PHARMACY: 460 SF
MODULE J CLINIC: 558 SF
F. PROJECT AREA OCCUPANT LOAD: INPATIENT PHARMACY: 69
OUTPATIENT PHARMACY: 2
MODULE J CLINIC: 7
G. FIRE PROTECTION: EXISTING BUILDING FULLY SPRINKLED. MODIFICATIONS AS REQUIRED PER NEW
IMPROVEMENTS PROPOSED
DRAWING INDEX:
BID ISSUE SUBMISSION
5.30.19
GI-1 TITLE SHEET & DRAWING INDEX
AS-0.1 PHASE IA & IB LIFE SAFETY PLANS
AS-0.2 PHASE II & III LIFE SAFETY PLANS
ARCHITECTURAL
INPATIENT PHARMACY:
AS-IP.0 BASEMENT LEVEL EXISTING CONDITIONS PLAN - INPATIENT PHARMACY
AS-IP.D1A BASEMENT LEVEL PHASE IA DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.D1AC BASEMENT LEVEL PHASE IA CEILING DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.1A BASEMENT LEVEL PHASE IA IMPROVEMENT PLAN - INPATIENT PHARMACY
AS-IP.1AC BASEMENT LEVEL PHASE IA REFLECTED CEILING PLAN - INPATIENT PHARMACY
AS-IP.D1B BASEMENT LEVEL PHASE IB DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.1B BASEMENT LEVEL PHASE IB IMPROVEMENT PLAN - INPATIENT PHARMACY
AS-IP.1BC BASEMENT LEVEL PHASE IB REFLECTED CEILING PLAN - INPATIENT PHARMACY
AS-IP.D2 BASEMENT LEVEL PHASE II DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.D2C BASEMENT LEVEL PHASE II CEILING DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.2 BASEMENT LEVEL PHASE II IMPROVEMENT PLAN - INPATIENT PHARMACY
AS-IP.2A FIRST AND SECOND FLOOR PHASE II IMPROVEMENT PLANS - INPATIENT PHARMACY
AS-IP.2B FIRST AND SECOND FLOOR PHASE II AIR HANDLER/DUCT ROUTING PLANS
AS-IP.2C BASEMENT LEVEL PHASE II REFLECTED CEILING PLAN - INPATIENT PHARMACY
AS-IP.D3 BASEMENT LEVEL PHASE III DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.D3C BASEMENT LEVEL PHASE III CEILING DEMOLITION PLAN - INPATIENT PHARMACY
AS-IP.3 BASEMENT LEVEL PHASE III IMPROVEMENT PLAN - INPATIENT PHARMACY
AS-IP.3C BASEMENT LEVEL PHASE III REFLECTED CEILING PLAN - INPATIENT PHARMACY
OUTPATIENT PHARMACY:
AS-OP.0 BASEMENT LEVEL EXISTING CONDITIONS PLAN - OUTPATIENT PHARMACY
AS-OP.D1 BASEMENT LEVEL PHASE I DEMOLITION PLAN - OUTPATIENT PHARMACY
AS-OP.1 BASEMENT LEVEL PHASE I IMPROVEMENT PLAN - OUTPATIENT PHARMACY
AS-OP.1C BASEMENT LEVEL PHASE I REFLECTED CEILING PLAN - OUTPATIENT PHARMACY
SECOND FLOOR MODULE J ONCOLOGY CLINIC:
AS-J2.0 SECOND FLOOR EXISTING CONDITIONS PLAN - MODULE J
AS-J2.D3 SECOND FLOOR PHASE III DEMOLITION PLAN - MODULE J
AS-J2.3 SECOND FLOOR PHASE III IMPROVEMENT PLAN - MODULE J
AS-J2.3C SECOND FLOOR PHASE III REFLECTED CEILING PLAN - MODULE J
AS-3.0 ENLARGED PLANS AND INTERIOR ELEVATIONS
AS-3.1 INTERIOR ELEVATIONS & MILLWORK DETAILS
AS-7.0 DOOR SCHEDULE, WALL TYPES, & DETAILS
AS-7.1 FINISH PLAN - PHASES I, II, & III - INPATIENT PHARMACY
AS-7.1.4 FINISH PLAN - PHASE IV - INPATIENT PHARMACY
AS-7.2 OUTPATIENT PHARMACY & MODULE J FINISH PLANS AND OVERALL FINISH SCHEDULE/DETAILS
MECHANICAL/HVAC
H-001 HVAC GENERAL NOTES AND SYMBOL LEGEND
INPATIENT PHARMACY:
H-IP.D1A BASEMENT LEVEL PHASE IA HVAC DEMOLITION PLAN - INPATIENT PHARMACY
H-IP.1A BASEMENT LEVEL PHASE IA HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
H-IP.D2 BASEMENT LEVEL PHASE II HVAC DEMOLITION PLAN - INPATIENT PHARMACY
H-IP.2.1 BASEMENT LEVEL PHASE II HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
H-IP.2.2 FIRST FLOOR LEVEL PHASE II HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
H-IP.2.3 SECOND FLOOR LEVEL PHASE II HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
H-IP.2.4 SECOND AND THIRD FLOOR SOUTH PHASE II HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
H-IP.D3 BASEMENT LEVEL PHASE III HVAC DEMOLITION PLAN - INPATIENT PHARMACY
H-IP.3.1 BASEMENT LEVEL PHASE III HVAC IMPROVEMENT PLAN - INPATIENT PHARMACY
OUTPATIENT PHARMACY:
H-OP.D1 BASEMENT LEVEL PHASE I HVAC DEMOLITION PLAN - OUTPATIENT PHARMACY
H-OP.1 BASEMENT LEVEL PHASE I HVAC IMPROVEMENT PLAN - OUTPATIENT PHARMACY
SECOND FLOOR MODULE J ONCOLOGY CLINIC:
H-J2.D3 SECOND FLOOR PHASE III HVAC DEMOLITION PLAN - MODULE J
H-J2.3 SECOND FLOOR PHASE III HVAC IMPROVEMENT PLAN - MODULE J
GENERAL HVAC:
H-100 HVAC DETAILS
H-200 HVAC TEMPERATURE CONTROLS
H-300 HVAC SCHEDULES
STRUCTURAL
S-IP.0 GENERAL NOTES AND SPECIFICATIONS
S-IP.1 PHASE I - ENLARGED CAROUSEL SUPPORT FRAMING PLAN - INPATIENT PHARMACY
S-IP.2 STRUCTURAL FRAMING PLANS
PLUMBING
P-001 PLUMBING GENERAL NOTES, SCHEDULES, DETAILS, AND SYMBOL LEGEND
INPATIENT PHARMACY:
P-IP.D1A BASEMENT LEVEL PHASE IA PLUMBING DEMOLITION PLAN - INPATIENT PHARMACY
P-IP.1A BASEMENT LEVEL PHASE IA PLUMBING IMPROVEMENT PLAN - INPATIENT PHARMACY
P-IP.D2 BASEMENT LEVEL PHASE II PLUMBING DEMOLITION PLAN - INPATIENT PHARMACY
P-IP.2 BASEMENT LEVEL PHASE II PLUMBING IMPROVEMENT PLAN - INPATIENT PHARMACY
P-IP.D3 BASEMENT LEVEL PHASE III PLUMBING DEMOLITION PLAN - INPATIENT PHARMACY
P-IP.3 BASEMENT LEVEL PHASE III PLUMBING IMPROVEMENT PLAN - INPATIENT PHARMACY
OUTPATIENT PHARMACY:
P-OP.1 BASEMENT LEVEL PHASE I PLUMBING IMPROVEMENT PLAN - OUTPATIENT PHARMACY
SECOND FLOOR MODULE J ONCOLOGY CLINIC:
P-J2.D3 SECOND FLOOR PHASE III PLUMBING DEMOLITION PLAN - MODULE J
P-J2.3 SECOND FLOOR PHASE III PLUMBING IMPROVEMENT PLAN - MODULE J
P-100 PLUMBING ISOMETRIC
FIRE PROTECTION
FP-001 FIRE PROTECTION GENERAL NOTES, DETAILS AND SYMBOL LEGEND
INPATIENT PHARMACY:
FP-IP.1A BASEMENT LEVEL PHASE IA FIRE PROTECTION IMPROVEMENT PLAN - INPATIENT PHARMACY
FP-IP.2 BASEMENT LEVEL PHASE II FIRE PROTECTION IMPROVEMENT PLAN - INPATIENT PHARMACY
FP-IP.3 BASEMENT LEVEL PHASE III FIRE PROTECTION IMPROVEMENT PLAN - INPATIENT PHARMACY
OUTPATIENT PHARMACY:
FP-OP.1 BASEMENT LEVEL PHASE I FIRE PROTECTION IMPROVEMENT PLAN - OUTPATIENT PHARMACY
SECOND FLOOR MODULE J ONCOLOGY CLINIC:
FP-J2.3 SECOND FLOOR PHASE III FIRE PROTECTION IMPROVEMENT PLAN - MODULE J
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES AND SYMBOL LEGEND
INPATIENT PHARMACY:
E-IP.D1 BASEMENT LEVEL PHASE I ELECTRICAL DEMOLITION PLAN - INPATIENT PHARMACY
E-IP.1.0 BASEMENT LEVEL PHASE I ELECTRICAL LIGHTING IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.1 BASEMENT LEVEL PHASE I ELECTIRCAL POWER IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.2 BASEMENT LEVEL PHASE I ELECTIRCAL SYSTEMS IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.D2 BASEMENT LEVEL PHASE II ELECTRICAL DEMOLITION PLAN - INPATIENT PHARMACY
E-IP.1.3 BASEMENT LEVEL PHASE II ELECTRICAL LIGHTING IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.4 BASEMENT LEVEL PHASE II ELECTIRCAL POWER IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.5 BASEMENT LEVEL PHASE II ELECTIRCAL SYSTEMS IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.D3 BASEMENT LEVEL PHASE III ELECTRICAL DEMOLITION PLAN - INPATIENT PHARMACY
E-IP.1.6 BASEMENT LEVEL PHASE III ELECTRICAL LIGHTING IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.7 BASEMENT LEVEL PHASE III ELECTIRCAL POWER IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.1.8 BASEMENT LEVEL PHASE III ELECTIRCAL SYSTEMS IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.2.0 FIRST FLOOR LEVEL PHASE II ELECTRICAL LIGHTING IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.2.1 FIRST FLOOR LEVEL PHASE II ELECTRICAL POWER IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.2.2 FIRST FLOOR LEVEL PHASE II ELECTRICAL SYSTEMS IMPROVEMENT PLAN - INPATIENT PHARMACY
E-IP.3.1 SECOND FLOOR LEVEL PHASE II ELECTRICAL POWER IMPROVEMENT PLAN - INPATIENT PHARMACY
OUTPATIENT PHARMACY:
E-OP.D1 BASEMENT LEVEL PHASE I ELECTRICAL DEMOLITION PLAN - OUTPATIENT PHARMACY
E-OP.1 BASEMENT LEVEL PHASE I ELECTRICAL LIGHTING IMPROVEMENT PLAN - OUTPATIENT PHARMACY
E-OP.2 BASEMENT LEVEL PHASE I ELECTRICAL POWER IMPROVEMENT PLAN - OUTPATIENT PHARMACY
E-OP.3 BASEMENT LEVEL PHASE I ELECTRICAL SYSTEMS IMPROVEMENT PLAN - OUTPATIENT PHARMACY
SECOND FLOOR MODULE J ONCOLOGY CLINIC:
E-J2.D3 SECOND FLOOR PHASE III ELECTRICAL DEMOLITION PLAN - MODULE J
E-J2.0 SECOND FLOOR PHASE III ELECTRICAL LIGHTING IMPROVEMENT PLAN - MODULE J
E-J2.1 SECOND FLOOR PHASE III ELECTRICAL POWER IMPROVEMENT PLAN - MODULE J
E-J2.2 SECOND FLOOR PHASE III ELECTRICAL SYSTEMS IMPROVEMENT PLAN - MODULE J
GENERAL ELECTRICAL:
E-100 LIGHTING FIXTURE SCHEDULE
E-101 PANELBOARD SCHEDULE
E-102 MECHANICAL EQUIPMENT SCHEDULES
E-103 ELECTRICAL DETAILS
PHASING DURATION:
THE SCOPE OF WORK DESCRIBED IN THIS DRAWING PACKAGE REPRESENTS A MULTI-PHASED
PROJECT THAT MUST BE UNDERTAKEN SIMULTANEOUSLY WITH THE FULL OCCUPANCY AND
FUNCTION OF THE EXISTING HOSPITAL. THE PROPOSING PHASING DURATION PLAN IS AS
FOLLOWS:
PRE-CONSTRUCTION: 60 DAYS
PHASE IA: 10 DAYS
VA ACTIVATION: 5 DAYS
PHASE IB: 10 DAYS
VA ACTIVATION: 5 DAYS
PHASE II: 120 DAYS
VA ACTIVATION: 30 DAYS
PHASE III: 90 DAYS
VA ACTIVATION: 15 DAYS
PHASE IV: 15 DAYS
TOTAL TIMEFRAME: 360 DAYS
THE FOLLOWING CONSTRUCTION SCHEDULE TIMEFRAMES SHALL APPLY TO THIS PROJECT:
ALL INPATIENT PHARMACY CONSTRUCTION: NORMAL SHIFT HOURS PERMITTED
ALL OUTPATIENT PHARMACY CONSTRUCTION: NORMAL SHIFT HOURS PERMITTED
ALL 2ND FLOOR MODULE J CONSTRUCTION: EVENING SHIFT HOURS ONLY (AFTER 5:30 PM)
THE TIMEFRAMES IDENTIFIED ABOVE ARE IN REFERENCE TO NORMAL CONSTRUCTION ACTIVITIES
AND, UNLESS APPROVED BY VA COR, SHALL NOT APPLY TO WORK INCLUDING BUT NOT LIMITED TO:
-UTILITY SHUTDOWNS
-EXISTING MEP SYSTEM SHUTDOWNS
-WORK IN PUBLIC CORRIDORS
-CUTTING OF FLOOR OPENINGS
-WORK OUTSIDE OF TEMPORARY CONSTRUCTION PARTITIONED AREAS, INCLUDING ACCESS
OF CEILING PLENUM SPACES IN FLOORS ABOVE OR BELOW CONSTRUCTION AREAS
WORK IDENTIFIED ABOVE SHALL OCCUR EITHER IN THE EVENING SHIFT, OR IF REQUIRED BY THE VA, ON WEEKENDS. ALL CONSTRUCTION ACTIVITIES AND SCHEDULES MUST BE REVIEWED AND
APPROVED BY COR. REFER TO SPEC DIVISION 01 FOR GENERAL PROJECT REQUIREMENTS
Revisions Date
5 BID ISSUE SUBMISSION 5.30.19
4 100% CD's SUBMISSION 12.21.18
3 90% CD's SUBMSSION 11.16.18
2 65% CD's SUBMISSION 10.12.18
1 35% CD's 8.20.18
DN
7'
7' - 0"
3'
EXISTING STAFF ENTRY DOOR SHALL BE INACCESSIBLE
DURING PHASE IA. EXISTING DOOR SHALL BE FULLY
SEALED FROM CONSTRUCTION ACTIVITIES
RESTROOMS BC324 & BC323 SHALL BE
INACCESSIBLE DURING PHASE IA. EXISTING
DOORS SHALL BE FULLY SEALED FROM
CONSTRUCTION ACTIVITIES
EXISTING STAFF DOOR SHALL BE
UTILIZED FOR CONSTRUCTION ENTRY
ONLY DURING PHASE IA. CARD READER
SHALL BE TEMPORARILY DISABLED BY
THE VA TO PERMIT CONTRACTOR
ACCESS.
TEMP. CONST.
"ANTEROOM"
6'-0" +/-
3' - 0"
E
E
FE
FE
F E
FE
FE
F E
P H
A S
E I A
S C
O P
E O
F
W
O R
K
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Corridor
BD311
Corridor
B-D311
Stair 5
E03
Conference
B-D352
Storage
BB418
Stair #8
BB420
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442 Corridor
BC400
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Toilet
BC472
Waiting
BC470
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314
ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A Laminating Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Tech Area
BB372
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378 Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Exam Visual Test
BB263
Toilet
BC323
Toilet
BC324
Office
BC306
Staff Lounge
BC305
Inpatient Pharmacy
BC307
Lockers
BC307A
Narcotics Vault
BC310
Buffer Area
BC309
Anteroom
BC308
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C
Mechanical
BC310A
Elevator Lobby
BC403
EXISTING EGRESS DOOR TO REMAIN
156'-6" +/- EXIT
TRAVEL DISTANCEEXISTING EGRESS PATH FROM
INPATIENT PHARMACY SHALL
REMAIN UNAFFECTED DURING
PHASE IA CONSTRUCTION. EXISTING
DOORS WILL NOT BE BLOCKED
PHASE IA
SCOPE OF
WORK
LIFE SAFETY LEGEND:
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA SAFETY
STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
EXISTING 2 HOUR RATED FIRE BARRIER
EXISTING 1 HOUR RATED FIRE BARRIER
EXISTING 1 HOUR RATED FIRE WALL/SMOKE BARRIER
EXISTING/NEW O HOUR RATED SMOKE PARTITION
E EXIT
FE
FIRE EXTINGUISHER
EXIT SIGN LOCATION (DIRECTIONAL ARROWS MAY
OCCUR, SEE PLAN)
LIFE SAFETY GENERAL NOTES:
1. SEE COVER SHEET FOR APPLICABLE CODE INFORMATION
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. CONTRACTOR WILL COMPLETE ALL WORK REGARDLESS IF IT IS LOCATED OUTSIDE OF PROJECT SCOPE AREA AS INDICATED ON ANY DRAWINGS
3. CONTRACTOR TO COVER OR ALTER EXIT SIGNS WHICH, DUE TO CONSTRUCTION, TEMPORARILY DO NOT
DEPICT EXIT PATHS (TYP. OF ALL EXIT SIGNS IN OR BEYOND PROJECT AREA)
4. TRAVEL DISTANCES OVER 200' WILL REQUIRE INTERIM LIFE SAFETY MEASURES. COORDINATE WITH VA.
5. EXISTING FLOOR SLABS ARE 2 HR RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONC. SLAB FULLY WITH NEW CONCRETE TO
MATCH EXISTING
6. PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH NEW AND EXISTING FIRE/SMOKE RATED BARRIER WALLS AND FLOOR SLABS TO COMPLY WITH THE REQUIRED BARRIER RATINGS. PROVIDE FIRESTOPPING AROUND TEN (10) PENETRATIONS LESS THAN 6 SQUARE INCHES AND FOUR (4) PENETRATIONS BETWEEN 16 AND 36 SQUARE INCHES TO COMPLY WITH REQUIRED RATING NOT ASSOCIATED WITH NEW WORK. LARGER OPENINGS SHALL BE BROUGHT TO THE ATTENTION OF THE COR. GC SHALL SUBMIT UL LISTED METHODS FOR PATCHING ALL FIRE BARRIERS THAT MEET THE MINIMUM FIRE RATING REQUIREMENTS OF THE PENETRATING BARRIER AND ARE IN COMPLIANCE WITH THE OPENING SIZE AS DICTATED BY THE ASSEMBLY.
7. TEMPORARY FIRE ALARMS IN CONSTRUCTION AREAS: GC SHALL PROVIDE TEMPORARY FIRE ALARMS IN ALL CONSTRUCTION AREAS THROUGHOUT THE CONSTRUCTION DURATION UNTIL SUCH TIME THAT NEW FIRE ALARM SYSTEM DEVICES ARE INSTALLED, TESTED, AND IN FULL OPERATION. HEAT DETECTION DEVICES SHALL BE UTILIZED AND SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND COORDINATED THROUGH THE VA ELECTRICAL SHOP. GC SHALL COORDINATE WITH VA SAFETY DEPARTMENT FOR ALL
TEMPORARY FIRE ALARM INSTALLATIONS TO ENSURE COMPLIANCE WITH SAFETY STANDARDS.
HAZARDOUS ROOM
EXISTING 2 HOUR RATED SMOKE BARRIER
GYP. BD./METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR
CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O.
PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY
CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-
7.0. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER
NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
PLASTIC CORRUGATED SHEETING/METAL STUD TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR CONTRACTOR ACCESS ONLY. REQUIRED AT ALL ABOVE-CEILING MECHANICAL/ELECTRICAL WORK LASTING LONGER THAN 8 HOURS OUTSIDE OF ENCLOSED CONSTRUCTION AREAS - REFER TO MEP
DRAWINGS FOR AFFECTED AREAS. SUCH WORK MUST BE ISOLATED FROM THE SURROUNDING
ENVIRONMENT. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "PLASTIC BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-7.0. SCHEDULE NOTE:
CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR. GC SHALL COORDINATE ALL ABOVE-CEILING WORK AND
TEMPORARY BARRIER CONSTRUCTION WITH VA AND PHARMACY STAFF
E
E
FE
FE
F E
FE
FE
F E
P H
A S
E I B
S C
O P
E O
F
W
O R
K
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Corridor
BD311
Corridor
B-D311
Stair 5
E03
Conference
B-D352
Corridor
CE02
Storage
BB418
Stair #8
BB420
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442 Corridor
BC400
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Toilet
BC472
Waiting
BC470
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314
ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A Laminating Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Tech Area
BB372
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378 Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Exam Visual Test
BB263
Toilet
BC323
Toilet
BC324
Office
BC306
Staff Lounge
BC305
Inpatient Pharmacy
BC307
Lockers
BC307A
Narcotics Vault
BC310
Buffer Area
BC309
Anteroom
BC308
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C
Mechanical
BC310A
Elevator Lobby
BC403
EXISTING EGRESS PATH FROM
INPATIENT PHARMACY SHALL REMAIN
UNAFFECTED DURING PHASE IB
CONSTRUCTION. EXISTING DOORS
WILL NOT BE BLOCKED
FE
F E
E
TEMPORARY CONST. BARRIER FOR
CONSTRUCTION OF NEW HD STORAGE
ROOM SHALL NOT IMPEDE
NORMAL/EGRESS TRAFFIC IN ANY WAY.
EX. DOUBLE DOORS SHALL REMAIN IN
NORMAL OPERATION. SEE SPECIAL
NOTE REGARDING DUCTWORK
SCOPE/BARRIERS
NORMAL EGRESS PATHS FROM OUTPATIENT
PHARMACY SHALL REMAIN UNAFFECTED
DURING THE MAJORITY OF CONSTRUCTION.
SEE SPECIAL NOTE REGARDING DUCTWORK
SCOPE/BARRIERS
F E
F E
P H
A S
E I S
C O
P E
O F
W
O R
K
Outpatient Pharmacy
BAC311
Storage
BAC301
HD Storage Room
BAC301A
Tech Sup. Mail Order
BAC312
Consult Room
BAC313
Staff Lockers/Break
BAC303
HAC
BAC302
Work Room
BAC307
Electrical Closet
BAC309 Comm
BAC308
Stairway
BAC310
Supervisor
BAC316
Tech Supply
BAC317
Controlled Sub,/ Sec Disp
BAC318
Record Storage
BAC320
Staff Toilet
BAC319
Consult
BAC321
Waiting
BAC326
Corridor
BAC327
Elevator Lobby
BAC325
SPECIAL NOTE: TEMPORARY CORRUGATED
PLASTIC SHEETING PARTITION INDICATED IS
ONLY REQUIRED FOR NEW DUCTWORK
ROUTING WORK. WHILE INSTALLED, EXISTING
EXIT THROUGH STORAGE BC301 WILL BE
TEMPORARILY BLOCKED. GC SHALL COORD.
W/VA SAFETY DEPT. TO ENSURE ALL SAFETY
MEASURES ARE IN PLACE
STAFF LOCKER ROOM AND HAC ROOM TO
BE TEMPORARILY UNOCCUPIED DURING
DUCTWORK INSTALLATION
ACCESS TO EXISTING EGRESS
STAIR SHALL BE PROVIDED
THROUGHOUT CONSTRUCTION
136'-10" ACCESS
TRAVEL DISTANCE TO
CORRIDOR
INFECTION CONTROL CLASS & SAFETY MEASURES:
THE FOLLOW INFECTION CONTROL CLASSES SHALL APPLY TO THIS PROJECT THROUGHOUT THE ENTIRETY OF
CONSTRUCTION:
• INPATIENT PHARMACY - CLASS III WITH ANTEROOM REQUIREMENT
• OUTPATIENT PHARMACY - CLASS III
• MODULE J ONCOLOGY CLINIC - CLASS IV WITH ANTEROOM REQUIREMENT
REFER TO DEMOLITION PLANS FOR SCOPE OF TEMPORARY CONSTRUCTION BARRIERS REQUIRED FOR THE PROJECT.
REFER TO AND FOLLOW ALL PROTOCOL IDENTIFIED IN "SAFETY REQUIREMENTS" 01 35 26 THROUGHOUT THE
ENTIRETY OF THE PROJECT.
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project Number
Drawing Number o n e-ei g h th in ch o n e fo o t o n e-q u a rt er in ch o n e fo o t th re e-e ig h th s in c h o n e fo o t o n e-h a lf in c h o n e fo o t th re e-q u a rt er s in ch o n e fo o t o n e in c h o n e fo o t o n e a n d o n e-h a lf in ch es o n e fo o t th re e in ch es o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SPRINKLERED
ARCHITECT:CONSULTANTS:
Office of Construction and Facilities Management
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
1468 WEST 9TH STREET #400 CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
E T
G
DE
I
RE
T
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
A
TE
I
T C
J.
O
O
FO
H
VETERANS AFFAIRS MEDICAL CENTER
RENOVATE PHARMACY TO COMPLY WITH
USP DIRECTIVES
5.30.19
PHASE IA & IB LIFE SAFETY PLANS
AS-0.1
541-19-103
10701 EAST BLVD. CLEVELAND, OHIO
Checker Author
SCALE: 3/32" = 1'-0"
PHASE IA LIFE SAFETY PLAN - INPATIENT PHARMACY
NORTH
SCALE: 3/32" = 1'-0"
PHASE IB LIFE SAFETY PLAN - INPATIENT PHARMACY
NORTH
SCALE: 3/32" = 1'-0"
PHASE IA LIFE SAFETY PLAN - OUTPATIENT PHARMACY
NORTH
Revisions Date
5 BID ISSUE SUBMISSION 5.30.19
4 100% CD's SUBMISSION 12.21.18
3 90% CD's SUBMSSION 11.16.18
DN
E
E
FE
F E
F E
FE
FE
F E
P H
A S
E I
II
S
C O
P E
O F
W
R
K
SPECIAL NOTE: THIS TEMPORARY DOOR SHALL BE PROVIDED WITH CARD READER WINTEGRAL SCRAMBLE PAD AND SHALL BE ACCESSIBLE BY VA STAFF ONLY. GC SHALL NOT HAVE ACCESS TO THIS DOOR UNLESS APPROVED BY THE COR UNDER SPECIAL CIRCUMSTANCES. INTENT OF TEMPORARY DOOR IS TO ALLOW VA STAFF ACCESS TO DELIVERIES DURING PHASE III CONSTRUCTION. GC SHALL COORD. W/VA PHARMACY STAFF AND PROVIDE DELIVERY ACCESS, AND SHALL MAINTAIN A CLEAR
DELIVERY PATH
SPECIAL NOTE: EXISTING, KEY-
CARD SECURED DOUBLE DOORS
SHALL SERVE AS THE SOLE
POINT OF PHARMACY DELIVERY
RECEIVING THROUGH PHASE III
CONSTRUCTION
SPECIAL NOTE: THIS ROOM WILL NOT
BE ACCESSIBLE TO CONSTRUCTION/GC
STAFF UNLESS APPROVED BY COR
UNDER SPECIAL CIRCUMSTANCES
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Corridor
BD311
Corridor
B-D311
Stair 5
E03
Conference
B-D352
Corridor
CE02
Storage
BB418
Stair #8
BB420
Theraputic Pool
BB421
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442 Corridor
BC400
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Toilet
BC472
Waiting
BC470
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314
ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A Laminating Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Tech Area
BB372
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378 Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Exam Visual Test
BB263
Inpatient Pharmacy
BC307
Corridor
BC307A
Narcotics Vault
BC310
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C
Mechanical
BC310A
Elevator Lobby
BC403
Sterile HD Buffer Area
BC305
HD Garbing
BC308
Open Work Area
BC327
Non-HD Garbing
BC325
Sterile Non-HD Buffer Area
BC324
Staff Lounge
BC321
HD Storage
BC309
Office
BC306
HD Anteroom
BC328
Non-HD Anteroom
BC326
Staff Toilet
BC323
181'-7" +/- EXIT ACCESS
TRAVEL DISTANCE
EGRESS FROM OPEN
OFFICE BC322 SHALL
REMAIN UNAFFECTED
DURING PHASE III
TEMP. CONST.
"ANTEROOM"
E
E
FE
F E
FE
FE
F E
PHASE II SCOPE OF WORK
F E
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Corridor
BD311
Corridor
B-D311
Stair 5
E03
Conference
B-D352
Storage
BB418
Stair #8
BB420
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442 Corridor
BC400
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Toilet
BC472
Waiting
BC470
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314
ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A Laminating Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Tech Area
BB372
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378 Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Exam Visual Test
BB263
Inpatient Pharmacy
BC307
Corridor
BC307A
Narcotics Vault
BC310
Buffer Area
BC309
Anteroom
BC308
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C
Mechanical
BC310A
Elevator Lobby
BC403
Sterile HD Buffer Area
BC305 HD Garbing
BC308
Open Work Area
BC327
Non-HD Garbing
BC325
Sterile Non-HD Buffer Area
BC324
Staff Lounge
BC321
Staff Toilet
BC323
HD Anteroom
BC328
Non-HD Anteroom
BC326
ACCESS TO EXISTING
EGRESS DOORS SHALL
REMAIN UNAFFECTED
DURING PHASE II
OPEN OFFICE BC322 SHALL HAVE
ACCESS TO TWO (2) EGRESS
DOORS DURING CONSTRUCTION.
THIRD DOOR SHALL ONLY BE
TEMPORARILY CLOSED OFF DURING
ADJACENT DUCTWORK
INSTALLATION WHEN TEMP.
BARRIER IS CONSTRUCTED
ACCESS TO NORTH EGRESS
DOORS SHALL PROVIDED AT ALL
TIMES - COORD. LOCATIONS OF
TEMP. CONSTRUCTION
BARRIERS AS REQ'D. IN COORD.
W/VA TO ACHIEVE SAME
184'-8" +/- EXIT ACCESS
TRAVEL DISTANCE
TEMP.
CONST.
"ANTEROOM"
LIFE SAFETY LEGEND:
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA SAFETY
STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
EXISTING 2 HOUR RATED FIRE BARRIER
EXISTING 1 HOUR RATED FIRE BARRIER
EXISTING 1 HOUR RATED FIRE WALL/SMOKE BARRIER
EXISTING/NEW O HOUR RATED SMOKE PARTITION
E EXIT
FE
FIRE EXTINGUISHER
EXIT SIGN LOCATION (DIRECTIONAL ARROWS MAY
OCCUR, SEE PLAN)
LIFE SAFETY GENERAL NOTES:
1. SEE COVER SHEET FOR APPLICABLE CODE INFORMATION
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. CONTRACTOR WILL COMPLETE ALL WORK REGARDLESS IF IT IS LOCATED OUTSIDE OF PROJECT SCOPE AREA AS INDICATED ON ANY DRAWINGS
3. CONTRACTOR TO COVER OR ALTER EXIT SIGNS WHICH, DUE TO CONSTRUCTION, TEMPORARILY DO NOT
DEPICT EXIT PATHS (TYP. OF ALL EXIT SIGNS IN OR BEYOND PROJECT AREA)
4. TRAVEL DISTANCES OVER 200' WILL REQUIRE INTERIM LIFE SAFETY MEASURES. COORDINATE WITH VA.
5. EXISTING FLOOR SLABS ARE 2 HR RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONC. SLAB FULLY WITH NEW CONCRETE TO
MATCH EXISTING
6. PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH NEW AND EXISTING FIRE/SMOKE RATED BARRIER WALLS AND FLOOR SLABS TO COMPLY WITH THE REQUIRED BARRIER RATINGS. PROVIDE FIRESTOPPING AROUND TEN (10) PENETRATIONS LESS THAN 6 SQUARE INCHES AND FOUR (4) PENETRATIONS BETWEEN 16 AND 36 SQUARE INCHES TO COMPLY WITH REQUIRED RATING NOT ASSOCIATED WITH NEW WORK. LARGER OPENINGS SHALL BE BROUGHT TO THE ATTENTION OF THE COR. GC SHALL SUBMIT UL LISTED METHODS FOR PATCHING ALL FIRE BARRIERS THAT MEET THE MINIMUM FIRE RATING REQUIREMENTS OF THE PENETRATING BARRIER AND ARE IN COMPLIANCE WITH THE OPENING SIZE AS DICTATED BY THE ASSEMBLY.
7. TEMPORARY FIRE ALARMS IN CONSTRUCTION AREAS: GC SHALL PROVIDE TEMPORARY FIRE ALARMS IN ALL CONSTRUCTION AREAS THROUGHOUT THE CONSTRUCTION DURATION UNTIL SUCH TIME THAT NEW FIRE ALARM SYSTEM DEVICES ARE INSTALLED, TESTED, AND IN FULL OPERATION. HEAT DETECTION DEVICES SHALL BE UTILIZED AND SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND COORDINATED THROUGH THE VA ELECTRICAL SHOP. GC SHALL COORDINATE WITH VA SAFETY DEPARTMENT FOR ALL
TEMPORARY FIRE ALARM INSTALLATIONS TO ENSURE COMPLIANCE WITH SAFETY STANDARDS.
HAZARDOUS ROOM
EXISTING 2 HOUR RATED SMOKE BARRIER
GYP. BD./METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR
CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O.
PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY
CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-
7.0. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER
NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
PLASTIC CORRUGATED SHEETING/METAL STUD TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR CONTRACTOR ACCESS ONLY. REQUIRED AT ALL ABOVE-CEILING MECHANICAL/ELECTRICAL WORK LASTING LONGER THAN 8 HOURS OUTSIDE OF ENCLOSED CONSTRUCTION AREAS - REFER TO MEP
DRAWINGS FOR AFFECTED AREAS. SUCH WORK MUST BE ISOLATED FROM THE SURROUNDING
ENVIRONMENT. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "PLASTIC BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-7.0. SCHEDULE NOTE:
CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR. GC SHALL COORDINATE ALL ABOVE-CEILING WORK AND
TEMPORARY BARRIER CONSTRUCTION WITH VA AND PHARMACY STAFF
P H
A S
E I
II
S
C O
P E
R
K
F E
F E
F E
Comm.
2B149
Hemodialysis Storage
2B150
Elect.
2B148
PFT
2B145
Passage
2B330
Stair #11
2B146
Corridor
2B147
Corridor
2B100A
Elect.
2B146A
Clean Linen
2B412
Procedure
2B413
Exam 8
2B414
Exam 7
2B415
Staff Lounge
2B411
Exam 4
2B420
Exam 3
2B421 Corridor
2B410
Corridor
2B418
Corridor
2B419
Exam 6
2B416
Exam 5
2B417
Exam 2
2B423
Exam 1
2B422
ASMT.
2B432Office
2B431
Nurse Intake
2B433
Storage
2B435 Corridor
2B459
Waiting
2B434
Recpt.
2B462
Pharmacy Office
2B461
Staff Toilet
2B460
Patient Toilet
2B438
EMS
2B436
Family/ Consult
2B437
Patient Toilet
2B439
Private Infusion
2B440
Med Room
2B456
Soiled
2B457 Infusion 1
2B441
Infusion 2
2B442
Infusion 3
2B443
Infusion 4
2B444
Infusion 5
2B445
Infusion 6
2B446 Infusion 7
2B447
Infusion 8
2B448
Infusion 9
2B449
Infusion 10
2B450
Infusion 11
2B451
Nurse Station
2B455
Corridor
2B459
Corridor
2B458
2B146B
Infusion 12
2B452
Infusion 13
2B453
Infusion 14
2B454
Infusion 15
2B454A
EXISTING
EGRESS
DOOR TO
REMAIN
EXISTING EGRESS PATH
TO REMAIN UNAFFECTED
DURING CONSTRUCTION
102'-4" +/- ACCESS
TRAVEL DISTANCE
TO MAIN ATRIUM
CORRIDOR
INFECTION CONTROL CLASS & SAFETY MEASURES:
THE FOLLOW INFECTION CONTROL CLASSES SHALL APPLY TO THIS PROJECT THROUGHOUT THE ENTIRETY OF
CONSTRUCTION:
• INPATIENT PHARMACY - CLASS III WITH ANTEROOM REQUIREMENT
• OUTPATIENT PHARMACY - CLASS III
• MODULE J ONCOLOGY CLINIC - CLASS IV WITH ANTEROOM REQUIREMENT
REFER TO DEMOLITION PLANS FOR SCOPE OF TEMPORARY CONSTRUCTION BARRIERS REQUIRED FOR THE PROJECT.
REFER TO AND FOLLOW ALL PROTOCOL IDENTIFIED IN "SAFETY REQUIREMENTS" 01 35 26 THROUGHOUT THE
ENTIRETY OF THE PROJECT.
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project Number
Drawing Number o n e-ei g h th in ch o n e fo o t o n e-q u a rt er in ch o n e fo o t th re e-e ig h th s in c h o n e fo o t o n e-h a lf in c h o n e fo o t th re e-q u a rt er s in ch o n e fo o t o n e in c h o n e fo o t o n e a n d o n e-h a lf in ch es o n e fo o t th re e in ch es o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SPRINKLERED
ARCHITECT:CONSULTANTS:
Office of Construction and Facilities Management
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
1468 WEST 9TH STREET #400 CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
E T
G
DE
I
RE
T
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
A
TE
I
T C
J.
O
O
FO
H
VETERANS AFFAIRS MEDICAL CENTER
RENOVATE PHARMACY TO COMPLY WITH
USP DIRECTIVES
5.30.19
PHASE II & III LIFE SAFETY PLANS
AS-0.2
541-19-103
10701 EAST BLVD. CLEVELAND, OHIO
Checker Author
SCALE: 3/32" = 1'-0"
PHASE III LIFE SAFETY PLAN - INPATIENT PHARMACY
NORTH
SCALE: 3/32" = 1'-0"
PHASE II LIFE SAFETY PLAN - INPATIENT PHARMACY
NORTH
SCALE: 3/32" = 1'-0"
PHASE III LIFE SAFETY PLAN - MODULE J
NORTH
TEMP. CONST.
"ANTEROOM"
Revisions Date
5 BID ISSUE SUBMISSION 5.30.19
4 100% CD's SUBMISSION 12.21.18
3 90% CD's SUBMSSION 11.16.18
UP
UP
UP
DN
UP
UP
UP
24 25 26 27
2924a 30
E
G1
H
JJ
KK
LL
L1
L2
N
P
Q
F
G
L3
17a
17a
18a
23d 24b 25a 26a 28a28 30a31
23a
N1 N1
23c
Research Lab
BD316
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Office
BD313
Lab Procedure-B
B-D355
Equip. Alcove
BD314
Corridor
BD311
Corridor
B-D311
Office
B-D353
Lab 7
B-D354
Stair 5
E03
Conference
B-D352
Storage
BB418
Stair #8
BB420
Service Room
BB419Corridor
BC400A
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442
Corridor
BC400
Corridor
BC430
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Corridor
BC470A
Toilet
BC472
Waiting
BC470
Biohazard Storage
E26
Service Lobby
BC404
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314 ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A
Laminating
Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378
Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362
Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Student Office
BB266
Student Office
BB267
Office
BB268
Office
BB270
Office
BB265
Office
BB264
Exam Visual Test
BB263
Toilet
BC323
Toilet
BC324
Office
BC306
Staff Lounge
BC305
Inpatient Pharmacy
BC307
Lockers
BC307A
Narcotics Vault
BC310
Buffer Area
BC309
Anteroom
BC308
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C Mechanical
BC310A
Elevator Lobby
BC403
PHASE II SCOPE OF WORK
PHASE II SCOPE OF WORK
P H
A S
E I B
S C
O P
E O
F
W
O R
K
P H
A S
E I A
S C
O P
E O
F
W
O R
K
P H
A S
E I
II
S
C O
P E
R
K
P H
A S
E I
II
S
C O
P E
R
K
FINAL CHECKING
STATION
DRUG
CAROUSEL
DRUG
CAROUSEL
DRUG
CAROUSEL
P H
A R
M A C
Y T
E C
H W
O R
K S T A T
IO
N S
P H
A R
M A C
Y T
E C
H W
O R
K S T A T
IO
N S
FILL STATION
T C
G R
X
IN
S P E C
T R x
TCGRX
EQUIP.
P H
A S
E I V
S C
O P
E O
F
W
O R
K
P H
A S
E I V
S C
O P
E O
F
W
O R
K
PHASE IV SCOPE OF WORK
GENERAL NOTE: ALL EXISTING
PARTITIONED WORKSTATIONS IN
OPEN OFFICE BC322 ARE
CONSIDERED "FURNITURE," AND
SHALL BE THE RESPONSIBILITY OF
THE VA TO REMOVE, AS WELL AS
DISCONNECT FROM EXISTING
ELECTRICAL WHIPS. NEW
WORKSTATIONS TO BE LOCATED IN
THIS AREA SHALL ALSO BE
FURNISHED & INSTALLED BY THE VA
GENERAL NOTE: UNLESS NOTED OTHERWISE ON
DEMO/IMPROVEMENT PLANS, ALL EXISTING WORKSTATIONS IN
INPATIENT PHARMACY BC307 ARE CONSIDERED "MOBILE
CASEWORK" THAT SHALL BE INCLUDED IN THE GC'S SCOPE OF
WORK WITH REGARDS TO REMOVAL AND/OR RELOCATION
P H
A S
E I V
S C
O P
E O
F
W
O R
K
P H
A S
E I V
S C
O P
E O
F
W
O R
K
PHASE IA SCOPE
OF WORK
P H
A S
E I B
S C
O P
E O
F
W
O R
K
PHASE II SCOPE OF WORK
GENERAL NOTES:
CONSIDER ALL AREAS OWNER-OCCUPIED UNLESS NOTED OTHERWISE.
ALL WALLS ARE DRAWN AND DIMENSIONED TO A 5" NOMINAL WIDTH TYPICAL UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE CLEAR DIMENSIONS FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
ALL SUB-CONTRACTORS (I.E. FIRE PROTECTION, HVAC, FIRE ALARM, ELECTRICAL, ETC.) TO DESIGN AND INSTALL SYSTEM PER OWNER REQUIREMENTS AND IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF ALL APPLICABLE
CODES.
PATCH AND REPAIR ALL EXISTING AREAS TO REMAIN AS REQUIRED TO MATCH EXISTING CONDITIONS.
WHERE NEW UTILITIES ARE TO BE INSTALLED IN EXISTING PARTITIONS, ALL SUB-CONTRACTORS SHALL REMOVE EXISTING DRYWALL AS REQUIRED FOR INSTALLATION OF SAME AND PATCH AND REPAIR WITH NEW TO MATCH
EXISTING CONDITIONS UPON COMPLETION OF UTILITY INSTALLATION.
ALL DAMAGE TO EXISTING AREAS OCCURING AS A RESULT OF CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY THE CONTRACTOR. CONTRACTOR SHALL PROTECT ALL EXISTING WALL, CEILING, AND FLOOR FINISHES IN EACH AREA. ANY SURFACES DAMAGED BY CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER.
ALL NEW PENETRATIONS IN FIRE-RATED ASSEMBLIES TO MAINTAIN FIRE RATING OF ASSEMBLY AS REQUIRED.
NEW AND EXISTING FURNITURE SHOWN FOR REFERENCE ONLY. THE OWNER SHALL REMOVE, PRIOR TO CONSTRUCTION, ALL ITEMS THAT THE OWNER DESIRES TO SALVAGE. ALL REMAINING ITEMS INDICATED TO BE DEMOLISHED SHALL BE REMOVED BY THE CONTRACTOR AND LEGALLY DISPOSED OF IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. ALL ITEMS TO REMAIN IN SPACE SHALL BE PROTECTED THROUGHOUT BY THE CONTRACTOR THROUGHOUT CONSTRUCTION. NEW FURNITURE TO BE FURNISHED AND INSTALLED BY THE OWNER
UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL PROVIDE DUST-REMOVAL WALK-OFF MATS (TACKY MAT) AT ALL CONSTRUCTION ENTRY
POINTS.
CONTRACTOR SHALL PROVIDE HEPA FILTERED NEGATIVE AIR MACHINE(S) TO MAINTAIN NEGATIVE PRESSURE IN WORK AREAS ENSURING NO DUST OR FUMES WILL BE TRANSFERRED TO OCCUPIED AREAS. PROVIDE VISUAL PRESSURE MONITORING DEVICE AT DUST-PROOF BARRICADE TO CONFIRM PRESSURE. DUST MONITORING SHALL BE BY OWNER. SEE SPECIFICATION 01 00 00 "GENERAL REQUIREMENTS" ATTACHMENT AND 01 35 26 "SAFETY
REQUIREMENTS" FOR ADDITIONAL REQUIREMENTS.
ALL DEMOLITION WORK BEING DONE OUTSIDE TEMPORARY PARTITIONS IS TO BE APPROPRIATELY SEALED OFF TO PREVENT THE TRANSMISSION OF DUST AND DEBRIS. WORK SHALL BE DONE TO MINIMIZE DISRUPTION TO
VISITORS, PATIENTS, AND STAFF. COORDINATE LOCATION OF BARRIERS WITH OWNER.
THE HOSPITAL'S SMOKE AND FIRE SUPPRESSION SYSTEM SHALL REMAIN IN OPERATION WITHIN THE PROJECT
AREA DURING THE ENTIRE CONSTRUCTION PHASE.
FIELD VERIFY LOCATION OF ALL EXISTING CONDITIONS. NOTIFY COR OF ANY DISCREPANCIES.
WHERE NEW DOORS ARE INDICATED IN EXISTING WALL ASSEMBLIES, CUT OPENINGS IN EXISTING WALL. REFER TO DOOR SCHEDULE FOR DIMENSIONS. PREPARE OPENINGS FOR NEW DOOR, INCLUSIVE OF THE ADDITION OF JAMB AND HEAD STUD REINFORCEMENT (I.E. DOUBLE STUDS, HEADERS) AND PATCH ADJACENT WALLS TO MATCH
EXISTING.
ALL FLOOR, WALL, CEILING, AND MISC. FIRE-RESISTIVE ASSEMBLIES AND CONSTRUCTION SHALL BE OF THE FIRE RATING CALLED FOR ON THE DRAWINGS AND/OR AS REQUIRED BY CODE. ALL EXISTING FIRE-RESISTIVE ASSEMBLIES SHALL BE MAINTAINED AND THE RATING NOT COMPROMISED. FIRE RATED ASSEMBLIES AND CONSTRUCTION INCLUDING ALL FIRESTOPPING, FIRE RATED DOORS, AND MISC. FIRE RESISTIVE REQUIREMENTS
SHALL BE LEFT UNCONCEALED AS REQUIRED FOR INSPECTION BY THE BUILDING OFFICIAL.
DEBRIS REMOVAL SHALL NOT INTERFERE WITH OWNER'S OPERATIONS AND SHALL OCCUR DURING OFF HOURS AS DETERMINED BY THE COR. SEE ALSO SPECIFICATION SECTION 01 35 26 "SAFETY REQUIREMENTS" FOR
ADDITIONAL REQUIREMENTS REGARDING THE HAULING OF DEBRIS FROM THE PROJECT AREA.
ALL NOISE-GENERATING OPERATIONS SHALL BE SCHEDULED SO AS NOT TO IMPEDE OWNER'S OPERATIONS AS DETERMINED BY THE COR. ALL WORK IN PUBLIC CORRIDORS SHALL BE PERFORMED OFF-HOURS UNLESS
OTHERWISE APPROVED BY THE COR.
EXISTING FLOOR SLABS ARE 2 HR FIRE RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND GC SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONCRETE SLAB FULLY WITH NEW CONCRETE TO MATCH EXISTING OR APPROVED 2 HR RATED INFILL FIRESTOP ASSEMBLY WHEN APPROVED BY THE COR.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
SYMBOL LEGEND:
INDICATES EXISTING DOOR
INDICATES NEW DOOR
EXISTING WALLS TO REMAIN
NEW WALLS
WALLS TO BE REMOVED FULL HEIGHT U.N.O.
DASHED LINES INDICATE ITEMS TO BE DEMOLISHED
HATCHED AREA OUTSIDE OF PROJECT SCOPE.
ACCESS INTO CEILING SPACES MAY OCCUR, REFER TO
MEP DWGS.
GYP. BD./METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR
CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O.
PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY
CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-
7.0. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER
NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA SAFETY
STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
GENERAL NOTE CONSTRUCTION PARTITION NOTE: WHERE TEMP. CONST. PARTITIONS CONFLICT W/EX.
LIGHTS/DIFFUSER/MEP ITEM LOCATIONS (INDICATED ON CEILING DEMOLITION PLANS), GC SHALL COORD. W/COR TO EITHER TEMPORARILY REMOVE SUCH ITEMS, OR ADJUST LOCATION OF CONST.
PARTITION ACCORDINGLY TO ALLOW ITEMS TO REMAIN IN PLACE
PLASTIC CORRUGATED SHEETING/METAL STUD TEMPORARY PARTITION WALL W/3'-0" X 7'-0" SCWD DOOR FOR CONTRACTOR ACCESS ONLY. REQUIRED AT ALL ABOVE-CEILING MECHANICAL/ELECTRICAL WORK LASTING LONGER THAN 8 HOURS OUTSIDE OF ENCLOSED CONSTRUCTION AREAS - REFER TO MEP
DRAWINGS FOR AFFECTED AREAS. SUCH WORK MUST BE ISOLATED FROM THE SURROUNDING
ENVIRONMENT. WALL AND DOOR TO BE REMOVED UPON COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "PLASTIC BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-7.0. SCHEDULE NOTE:
CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR. GC SHALL COORDINATE ALL ABOVE-CEILING WORK AND
TEMPORARY BARRIER CONSTRUCTION WITH VA AND PHARMACY STAFF
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project Number
Drawing Number o n e-ei g h th in ch o n e fo o t o n e-q u a rt er in ch o n e fo o t th re e-e ig h th s in c h o n e fo o t o n e-h a lf in c h o n e fo o t th re e-q u a rt er s in ch o n e fo o t o n e in c h o n e fo o t o n e a n d o n e-h a lf in ch es o n e fo o t th re e in ch es o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SPRINKLERED
ARCHITECT:CONSULTANTS:
Office of Construction and Facilities Management
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
1468 WEST 9TH STREET #400 CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
E T
G
DE
I
RE
T
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
A
TE
I
T C
J.
O
O
FO
H
VETERANS AFFAIRS MEDICAL CENTER
RENOVATE PHARMACY TO COMPLY WITH
USP DIRECTIVES
5.30.19
BASEMENT LEVEL EXISTING
CONDITIONS PLAN - INPATIENT
PHARMACY
AS-IP.0
541-19-103
10701 EAST BLVD. CLEVELAND, OHIO
CJK DAK
SCALE: 1/8" = 1'-0"
BASEMENT LEVEL EXISTING CONDITIONS PLAN - INPATIENT PHARMACY
NORTH
Revisions Date
5 BID ISSUE SUBMISSION 5.30.19
4 100% CD's SUBMISSION 12.21.18
3 90% CD's SUBMSSION 11.16.18
UP
UP
UP
UP
UP
UP
DRUG
CAROUSEL
DRUG
CAROUSEL
DRUG
CAROUSELT
C G R X
IN
S P E C T R x
TCGRX
EQUIP.
4'
Research Lab
BD316
Women's Toilet
BD312A
Men's Toilet
BD312
Lab Procedure-C
BD310
Office
BD313
Lab Procedure-B
B-D355
Equip. Alcove
BD314
Corridor
BD311
Corridor
B-D311
Office
B-D353
Lab 7
B-D354
Stair 5
E03
Conference
B-D352
Storage
BB418
Stair #8
BB420
Dietitian
BC421
Conference Room
BC410
Reading Room
BC443
Cardiology Tech
BC442
Corridor
BC400
Staff
BC441
Echo
BC437
Echo
BC435
Echo
BC433
Reception
BC471A
Work
BC471
Toilet
BC472
Waiting
BC470
Biohazard Storage
E26
Service Lobby
BC404
Tech Supv
BC311
IP Chief
BC312
Alcove
BC313
Staff Entry
BC314
ELEC.
BC315
Assistant Chief
BC316
Secretary & Waiting
BC317
Chief Pharm.
BC318
Admin. Assist.
BC319
Clinic Coord.
BC320
IT
BB379
Open Office
BC322
Mainstreet Corridor
BC402
Closet
BB375A
Laminating Room
BB375
Machine Room
BB374
Cad Room
BB373
Corridor
BC401
Tech Area
BB372
Paster Room
BB376
Office
BB377
Casting Exam Room
BB378
Vestibule
BB370
Gait Room
BB371
Corridor
BB300E
Elect.
BB362
Vestibule
BB360
Inventory Storeroom
BB361
Conference
BB261
Corridor
BB260
Reception
BB262
Office
BB262A
Student Office
BB266
Student Office
BB267
Office
BB268
Office
BB270
Stair 9
BCS2
Storage
BB269
Office
BB265
Office
BB264
Exam Visual Test
BB263
Toilet
BC323
Toilet
BC324
Office
BC306
Staff Lounge
BC305
Inpatient Pharmacy
BC307
Lockers
BC307A
Narcotics Vault
BC310
Buffer Area
BC309
Anteroom
BC308
EMS
BC302
Future Machine Room
BC303
Receiving Area
BC304
Storage
BC301
Mainstreet
BD300A
Lobby
BD300B
Lobby
BD300C
Mechanical
BC310A
Elevator Lobby
BC403
Corridor
BB300F
3' - 0"
RESTROOMS BC324 & BC323
SHALL BE INACCESSIBLE DURING
PHASE IA. EXISTING DOORS
SHALL BE FULLY SEALED FROM
CONSTRUCTION ACTIVITIES
ALIGN
ALIGN
7'
3'
7' - 0" 9' - 2 1/2"
ALIGN CONST. WALL
W/EDGE OF WORKSTATION
2' - 6"
ALIGN FLUSH
ALIGN
9 9
EXISTING STAFF ENTRY DOOR SHALL BE INACCESSIBLE
DURING PHASE IA. EXISTING DOOR SHALL BE FULLY
SEALED FROM CONSTRUCTION ACTIVITIES
6'
EXISTING STAFF DOOR SHALL BE
UTILIZED FOR CONSTRUCTION
ENTRY ONLY DURING PHASE IA.
CARD READER SHALL BE
TEMPORARILY DISABLED BY THE VA
TO PERMIT CONTRACTOR ACCESS.
ALIGN EXISTING
FLOORING/BASE REMOVAL
WITH EX. WORKSTATIONS AND
REAR OF DRUG CAROUSEL
TEMP. CONST.
"ANTEROOM"
EXISTING FIRE
EXTINGUISHERS TO REMAIN
ENTIRE OPEN
OFFICE BC322
SPACE
PHASING NOTE: THE INTENT IN DIVIDING PHASE I INTO TWO (2) SEPARATE PHASES - PHASE IA AND IB - IS TO ACCOMMODATE THE TEMPORARY RELOCATION OF PHARMACY STAFF IN PHASES SO AS NOT TO DISRUPT
OPERATIONS. THE PHASES ARE DESIGNED TO GENERALLY ACHIEVE THE FOLLOWING:
PHASE IA: DEMO EXISTING WALLS AND CONSTRUCT NEW WALL. STAFF LOCATED WITHIN CONSTRUCTION AREAS WILL BE TEMPORARILY RELOCATED BY THE VA, WHILE STAFF OUTSIDE CONSTRUCTION BARRIERS SHALL REMAIN IN PLACE AND UNINTERRUPTED. CREATE NEW WORKSTATIONS IN CONSTRUCTION AREA.
PHASE IB: NEW STAFF WORKSTATIONS CREATED IN PHASE IA WILL BE UTILIZED BY PHARMACY STAFF WHILE PHASE IB IS UNDERTAKEN. PHASE IB IS ALSO THE PHASE WHERE CRITICAL STATIONS AND EQUIPMENT WILL BE RELOCATED OR CREATED AT THEIR FINAL LOCATION (E.G. FINAL CHECKING, DRUG REFRIGERATORS, TCGRX EQUIPMENT, FILL STATION).
AT THE END OF PHASE IB - I.E. THE COMPLETION OF PHASE I - THE PHARMACY STAFF AND CRITICAL EQUIPMENT WILL BE LOCATED IN THEIR FINAL LOCATIONS AND IN FULL USE BY THE PHARMACY STAFF FOR
THE REMAINDER OF CONSTRUCTION. GC SHALL COORDINATE AND SCHEDULE ALL SUBSEQUENT
CONSTRUCTION PHASES (II, III, & IV) WITH VA/PHARMACY STAFF TO ENSURE THAT CONTINUOUS
OPERATIONS OF PHASE IA/IB STAFF AND EQUIPMENT CAN BE MAINTAINED.
GENERAL NOTES:
CONSIDER ALL AREAS OWNER-OCCUPIED UNLESS NOTED OTHERWISE.
ALL WALLS ARE DRAWN AND DIMENSIONED TO A 5" NOMINAL WIDTH TYPICAL UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE CLEAR DIMENSIONS FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
ALL SUB-CONTRACTORS (I.E. FIRE PROTECTION, HVAC, FIRE ALARM, ELECTRICAL, ETC.) TO DESIGN AND INSTALL SYSTEM PER OWNER REQUIREMENTS AND IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF ALL APPLICABLE
CODES.
PATCH AND REPAIR ALL EXISTING AREAS TO REMAIN AS REQUIRED TO MATCH EXISTING CONDITIONS.
WHERE NEW UTILITIES ARE TO BE INSTALLED IN EXISTING PARTITIONS, ALL SUB-CONTRACTORS SHALL REMOVE EXISTING DRYWALL AS REQUIRED FOR INSTALLATION OF SAME AND PATCH AND REPAIR WITH NEW TO MATCH
EXISTING CONDITIONS UPON COMPLETION OF UTILITY INSTALLATION.
ALL DAMAGE TO EXISTING AREAS OCCURING AS A RESULT OF CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY THE CONTRACTOR. CONTRACTOR SHALL PROTECT ALL EXISTING WALL, CEILING, AND FLOOR FINISHES IN EACH AREA. ANY SURFACES DAMAGED BY CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER.
ALL NEW PENETRATIONS IN FIRE-RATED ASSEMBLIES TO MAINTAIN FIRE RATING OF ASSEMBLY AS REQUIRED.
NEW AND EXISTING FURNITURE SHOWN FOR REFERENCE ONLY. THE OWNER SHALL REMOVE, PRIOR TO CONSTRUCTION, ALL ITEMS THAT THE OWNER DESIRES TO SALVAGE. ALL REMAINING ITEMS INDICATED TO BE DEMOLISHED SHALL BE REMOVED BY THE CONTRACTOR AND LEGALLY DISPOSED OF IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. ALL ITEMS TO REMAIN IN SPACE SHALL BE PROTECTED THROUGHOUT BY THE CONTRACTOR THROUGHOUT CONSTRUCTION. NEW FURNITURE TO BE FURNISHED AND INSTALLED BY THE OWNER
UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL PROVIDE DUST-REMOVAL WALK-OFF MATS (TACKY MAT) AT ALL CONSTRUCTION ENTRY
POINTS.
CONTRACTOR SHALL PROVIDE HEPA FILTERED NEGATIVE AIR MACHINE(S) TO MAINTAIN NEGATIVE PRESSURE IN WORK AREAS ENSURING NO DUST OR FUMES WILL BE TRANSFERRED TO OCCUPIED AREAS. PROVIDE VISUAL PRESSURE MONITORING DEVICE AT DUST-PROOF BARRICADE TO CONFIRM PRESSURE. DUST MONITORING SHALL BE BY OWNER. SEE SPECIFICATION 01 00 00 "GENERAL REQUIREMENTS" ATTACHMENT AND 01 35 26 "SAFETY
REQUIREMENTS" FOR ADDITIONAL REQUIREMENTS.
ALL DEMOLITION WORK BEING DONE OUTSIDE TEMPORARY PARTITIONS IS TO BE APPROPRIATELY SEALED OFF TO PREVENT THE TRANSMISSION OF DUST AND DEBRIS. WORK SHALL BE DONE TO MINIMIZE DISRUPTION TO
VISITORS, PATIENTS, AND STAFF. COORDINATE LOCATION OF BARRIERS WITH OWNER.
THE HOSPITAL'S SMOKE AND FIRE SUPPRESSION SYSTEM SHALL REMAIN IN OPERATION WITHIN THE PROJECT
AREA DURING THE ENTIRE CONSTRUCTION PHASE.
FIELD VERIFY LOCATION OF ALL EXISTING CONDITIONS. NOTIFY COR OF ANY DISCREPANCIES.
WHERE NEW DOORS ARE INDICATED IN EXISTING WALL ASSEMBLIES, CUT OPENINGS IN EXISTING WALL. REFER TO DOOR SCHEDULE FOR DIMENSIONS. PREPARE OPENINGS FOR NEW DOOR, INCLUSIVE OF THE ADDITION OF JAMB AND HEAD STUD REINFORCEMENT (I.E. DOUBLE STUDS, HEADERS) AND PATCH ADJACENT WALLS TO MATCH
EXISTING.
ALL…