36C25018B0688-002.pdf
PDF 27 MB Posted
- Attached to
- Build Primary Care Clinic (PACT) Project 610-303
- Solicitation number
- 36C25018B0688
About this file
36C25018B0688 ATTACHMENT 1. 05.1a 610-303 VOL 1 Drawings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25018B0688-010.docx | DOCX document | |
| 36C25018B0688-0003000.docx | DOCX document | |
| 36C25018B0688-0002001.pdf | ||
| 36C25018B0688-0002000.docx | DOCX document | |
| 36C25018B0688-0001015.pdf | ||
| 36C25018B0688-0001017.pdf | ||
| 36C25018B0688-0001014.docx | DOCX document | |
| 36C25018B0688-0001016.pdf | ||
| 36C25018B0688-0001013.pdf | ||
| 36C25018B0688-0001012.docx | DOCX document | |
| 36C25018B0688-007.pdf | ||
| 36C25018B0688-001.docx | DOCX document | |
| 36C25018B0688-009.docx | DOCX document | |
| 36C25018B0688-008.pdf | ||
| 36C25018B0688-003.pdf | ||
| 36C25018B0688-005.pdf | ||
| 36C25018B0688-004.pdf | ||
| 36C25018B0688-006.docx | DOCX document | |
| 36C25018B0688-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Kuder Place
Indiana Avenue Indiana Avenue
H y d e R o a d
Irw in
D riv e
Chapman Avenue
H y d e R o a d
M a rio n R o a d
O rc h a rd
A v e n u e
Indiana Avenue
F lo w e r
S tre e t
F lo w e r
S tre e t
Chapman Avenue
N e ls o n A v e n u e
O rc h a rd
A v e n u e
Chapman Avenue
River Road
National Cemetary
National Cemetary
National Cemetary
D
IX
R O A D
P A R K
D R
IV
E
38 Street
L in c o ln
B o u le v a rd
McMahon
G ra y R o a d
Steel Circle
Avenue
C o tt a g e
A v e n u e
B la c k
R o a d
B la c k R o a d
C o tt a g e
A v e n u e
G ra y R o a d
Water Street
B lack R oad
Water Street
Nelson
Avenue
Orchard
Avenue
M c M a h o n
A v e n u e
Doctors Road
V in e
Drive
Vine
Water Street
Railroad Avenue
M e c h a n i c s A v e n u e
R
I
V
E
R
R o a d
Road
Material Compound
54 153
T504
T516
53144
51 52
75 55
17 184
93114
313029
91 125
(3001)
(1301)
Main Entrance
(3002)
(HA-2)
(4801)
(HA-4)
(HA-6)
(HA-5)
(3004)
(3G01)
(HA9)
(HA1)
(HA8)
PROJECT LAYDOWN
AREA / CONTRACTOR
PARKING AREA
PROJECT AREA
CONTRACTOR HAUL ROUTE
PROJECT LOCATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
9 2
-A
-N ew C en tr a l _M
IN
E
LS
O
N .r vt
/2
/2
:5 :5
P
M
G-000
COVER 610-303 / 269296
03/19/18 MT ETD
ISSUED FOR
CONSTRUCTION
Project Director
1700 E 38TH ST, MARION, IN 46953
BUILD PRIMARY CARE CLINIC - PACT
FULLY SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTEL SR ,RA, LEED
AP BD+C
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
ABONMARCHE
750 LINCOLN WAY EAST
SOUTH BEND, IN 46601
574.232.8700
BRAD MOSNESS
CONTRACT DOCUMENTS - ISSUE FOR CONSTRUCTION
GENERAL/CIVIL/STRUCTURE/ARCHITECTURAL/FIRE PROTECTION/PLUMBING/MECHANICAL/ELECTICAL
Project No.
Date:
610-303 / 269296
BUILD PRIMARY CARE CLINIC - PACT
1700 E 38TH ST, MARION, IN 46953
03/19/2018
CAMPUS SITE PLAN LOCATION MAP
INDEX OF DRAWINGS
SHEET # DESCRIPTION
CURRENT
REVISION
INTERIORS
I-10B INTERIOR FLOOR AND WALL FINISH PLANS - BASEMENT
I-101 INTERIOR WALL FINISH PLAN - FIRST FLOOR
IN101 INTERIOR FLOOR FINISH PLAN - FIRST FLOOR
IP101 WALL PROTECTION PLAN - FIRST FLOOR
I-201 ELEVATIONS - INTERIOR
I-202 ELEVATIONS - INTERIOR
I-203 ELEVATIONS- INTERIOR
I-501 INTERIOR DETAILS
EQUIPMENT
Q-101D FURNITURE AND EQUIPMENT PLANS - AREA D
Q-101E FURNITURE AND EQUIPMENT PLANS - AREA E
Q-601 FURNITURE AND EQUIPMENT MASTER SCHEDULE
Q-602 EQUIPMENT SCHEDULE AREA D
Q-603 EQUIPMENT SCHEDULE AREA E
FIRE PROTECTION
FX201 FIRE PROTECTION PLANS
FJ501 FIRE PROTECTION SCHEDULES, DETAILS & SYMBOLS LIST
PLUMBING
PP200 PLUMBING BASEMENT & UNDERFLOOR PLANS
PP201 PLUMBING FIRST FLOOR PLANS
PP202 PLUMBING ROOF PLAN
PP401 PLUMBING ENLARGED PLAN
PP402 PLUMBING ENLARGED PLAN
PG301 MEDICAL GAS PIPING PLANS
PQ501 PLUMBING SCHEDULES & SYMBOLS LIST
PQ601 PLUMBING DETAILS
PQ602 PLUMBING DETAILS
PQ603 PLUMBING DETAILS
PW701 PLUMBING STACKS
PW702 PLUMBING STACKS
PW703 PLUMBING RISER & DIAGRAMS
MECHANICAL
MH201 HVAC FIRST FLOOR PLANS
MH301 HVAC PIPING FIRST FLOOR NEW WORK PLANS
MH401 HVAC ENLARGED PLAN
MH402 HVAC SECTIONS
MH501 HVAC SCHEDULES & SYMBOLS LIST
MH502 HVAC SCHEDULES
MH601 HVAC DETAILS
MH602 HVAC DETAILS
MH701 HVAC ZONE DIAGRAM
ELECTRICAL
E-000 ELECTRICAL SYMBOLS LIST
ED001 ELECTRICAL SITE PLAN - DEMO
ED101 ELECTRICAL FIRST FLOOR DEMOLITION
ES002 ELECTRICAL SITE PLAN - NEW
EL201 ELECTRICAL BASEMENT LIGHTING PLAN
EL202 ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA D
EL203 ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA E
EP301 ELECTRICAL BASEMENT POWER PLAN
EP302 ELECTRICAL FIRST FLOOR POWER PLAN - AREA D
EP303 ELECTRICAL FIRST FLOOR POWER PLAN - AREA E
EP304 ELECTRICAL FIRST LIGHTNING PLAN - OVERAL
EP401 ELECTRICAL ENLARGED PLANS
EJ501 ELECTRICAL SCHEDULES
EJ502 ELECTRICAL SCHEDULES
EJ601 ELECTRICAL ONE-LINE DIAGRAM
EJ602 ELECTRICAL ONE-LINE DIAGRAM SCHEDULES
EK701 ELECTRICAL DETAILS
EK702 ELECTRICAL DETAILS
EK703 ELECTRICAL DETAILS
FA801 ELECTRICAL BASEMENT FIRE ALARM PLAN
FA802 ELECTRICAL FIRST FLOOR FIRE ALARM PLAN -AREA D
FA803 ELECTRICAL FIRST FLOOR FIRE ALARM PLAN -AREA E
ET000 TECHNOLOGY SYMBOL LIST
ET001 TECHNOLOGY SITE PLAN
ET101 TECHNOLOGY BASEMENT PLAN
ET201 TECHNOLOGY FIRST FLOOR PLAN - AREA D
ET202 TECHNOLOGY FIRST FLOOR PLAN - AREA E
ET301 TECHNOLOGY ENLARGED PLANS
ET401 TECHNOLOGY DETAILS
ET402 TECHNOLOGY DETAILS
ET403 TECHNOLOGY DETAILS
INDEX OF DRAWINGS
SHEET # DESCRIPTION
CURRENT
REVISION
GENERAL
G-000 COVER
G-101 ABBREVIATIONS AND SYMBOLS
GC-101 PROJECT PHASING
GI-001 LIFE SAFETY PLANS
GI-200 INFECTION CONTROL PLAN
CIVIL
GS01 COVER SHEET
GS02 TOPOGRAPHIC SURVEY
GS03 REMOVALS PLAN
GS04 SITE DEVELOPMENT PLAN
GS05 UTILITY RELOCATION PLAN
GS06 DRAINAGE AND GRADING PLANS
GS07 CONSTRUCTION DETAILS
GS08 CONSTRUCTION DETAILS
GS09 CONSTRUCTION DETAILS
GS10 CONSTRUCTION DETAILS (VA STANDARDS)
GS11 STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
GS12 STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
GS13 STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
GS14 STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
GS15 STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
STRUCTURAL
SB100 BASEMENT FOUNDATION
SF100 FOUNDATION AND FRAMING PLAN
SF101 ROOF BOTTOM REINFORCING
SF102 ROOF TOP REINFORCING
SF103 CANOPY PLANS AND DETAIL
SJ100 STRUCTURAL DETAILS
SJ101 STRUCTURAL DETAILS
SJ102 STUCTURAL NOTES
SJ103 BEAM SCHEDULE
ARCHITECTURE
A-002 TYP. MOUNTING HEIGHTS
A-003 ALTERNATE DEFINITIONS
AD101 PLAN - DEMOLITION
A-10B PLAN - BASEMENT
A-101 PLAN - FIRST FLOOR
A-101D FLOOR PLAN, FIRST FLOOR - AREA D
A-101E FLOOR PLAN, FIRST FLOOR - AREA E
A-103 PLAN - ROOF
AC10B REFLECTED CEILING PLAN - BASEMENT
AC101 REFLECTED CEILING PLAN - FIRST FLOOR
AC101D REFLECTED CEILING PLAN - AREA D
AC101E REFLECTED CEILING PLAN - AREA E
A-200 ELEVATIONS - EXTERIOR BUILDING
A-201 ELEVATIONS - EXTERIOR BUILDING
A-301 SECTIONS - BUILDING
A-302 SECTIONS - BUILDING
A-350 SECTIONS - EXTERIOR WALL
A-351 SECTIONS - EXTERIOR WALL
A-460 CASEWORK
A-461 CASEWORK
A-501 SECTIONS - DETAILS
A-502 SECTIONS - DETAILS
A-503 SECTIONS - DETAILS
A-520 PLAN DETAILS
A-521 PLAN DETAILS
A-540 SECTIONS/ PLANS DETAILS - STAIRS
A-550 DETAILS
A-601 DOOR AND FRAME SCHEDULE
A-710 DOOR AND FRAME TYPES & DETAILS
A-711 SLIDING DOOR DETAILS
A-712 SLIDING DOOR DETAILS
A-720 INTERIOR PARTITION TYPES AND DETAILS
A-721 HEAD-OF-WALL DETAILS
A-722 PARTITION FRAMING DETAILS
A-730 CEILING DETAILS
AW10A SIGNAGE MESSAGE SCHEDULE BASEMENT AND FIRST FLOOR
AW10B SIGNAGE- PLAN - BASEMENT - OVERALL
AW101 SIGNAGE- PLAN - FIRST FLOOR - OVERALL
AW102 INTERIOR SIGNAGE STANDARDS
AW103 INTERIOR SIGNAGE-LIFESAFETY SIGN TYPES IN-01.01.01- IN-01.05
AW104 INTERIOR SIGNAGE LIFE SAFETY SIGN TYPES IN-01.11- IN-01.22
AW105 INTERIOR SIGNAGE - ROOM ID SIGN TYPE IN-04.03 - IN-09.03
AW106 INTERIOR SIGNAGE – WAYFINDING SIGN TYPE IN-14.04 - IN-17.05
AW751 SIGNAGE
Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
STAMP
03-19-18
Page 1 of 141Page 1 of 141
VOLUME 1
GENERAL
CIVIL
STRUCTURAL
S
ARCHITECTURAL SYMBOLS
COLUMN GRID LINE
(EXISTING)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM TAG
ROOM NAME
ROOM NUMBER
DOOR NUMBER
SYMBOL AND MINIMUM
CLEARANCES
WALL LEGEND
ACTUAL AREA OR VOLUME
DETAIL - SECTION
POSITION ON SHEET
SHEET NUMBER
DETAIL - PLAN/ RCP
POSITION ON SHEET
SHEET NUMBER
BUILDING SECTION
POSITION ON SHEET
SHEET NUMBER
WALL SECTION
POSITION ON SHEET
SHEET NUMBER
EXTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
INTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
WALL TYPE TAG
FRAME TYPE -
EXTERIOR & LOUVER
CURTAIN / GLAZING
PANEL TYPE
DRAWING NUMBER
DRAWING SCALE
DRAWING NUMBER
DRAWING SCALE
SHEET NUMBER
REFERENCING SHEET
NUMBER
VIEW TITLE
VIEW TITLE WITH REFERENCE
KEYNOTE
DRAWING REVISION
LEVEL DATUM
LEVEL NAME
LEVEL ELEVATION
NORTH ARROW
FRAME TYPE - INTERIOR
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
18" MIN.
12" MIN.
4" MIN.
1A
≠ X# X X
XX
XX
1T
X
Name Elevation
SIM
X-XXX
X
SIM
X-XXX
X
XXXX
X
X X
X
A-1 1/8" = 1'-0"
View Name
1/8" = 1'-0"
View NameA-1 A101R101
ROOM NAME
ABC123
P:200 SF
A:150 SF
7'-0"
R 3'-11"
100.0°
DIMENSION TO FACE OF
FINISH, FACE OF CONCRETE,
COLUMN CENTERLINE, OR AS
NOTED.
CENTERLINE
COLUMN GRID LINE
(NEW)
MATCHLINE
SEE: X/X-XXX
X
SEE: (X/X-XXX)
VIEW REFERENCE FOR
ADDITIONAL INFORMATION
REFERENCE TO AREA
MATCHLINE AND VIEW
REFERENCE
SIM
X
X-XXX
SIM
X
X-XXX
SIM
X
X-XXX
X
X-XXX
SIM
GRAPHIC SCALE
PROGRAMMED AREA
ROOM CODE
ABBREVIATIONS
° DEGREE
± PLUS/MINUS
Ø DIAMETER
≈ ALMOST EQUAL
∠ ANGLE
� BOUNDARY LINE
℄ CENTER LINE
∆ DELTA, DEFLECTION ANGLE
Φ ELECTRICAL PHASE
� FLOW LINE
≡ IDENTITY
� INITIAL LENGTH
� MOMENT LINE
≠ NOT EQUAL
Ω OHM
Ω OMEGA
� PROPERTY LINE
ABCDEFGHIJKMNOPQRSTUVWXYZ 1234567890
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT, AUGER BORING
ABA ARCHITECTURAL BARRIERS ACT
ABC AGGREGATE BASE COURSE
ABS AIR BREAK SWITCH
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE
ACB AIR CIRCUIT BREAKER
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
ADO AUTOMATIC DOOR OPERATOR
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AL ALUMINUM
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AM ACOUSTIC MATERIAL
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ANT ANTENNA
AP ACCESS PANEL, APPROX.,
APPROXIMATE
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARR ARRESTOR
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING
INSTITUTE
AWPA AMERICAN WOOD PRESERVERS'
ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B BASELINE, BOTTOM
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEJ BRICK EXPANSION JOINT
BEV BEVEL
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BO BOARD
BOT BOTTOM
BR BEDROOM, BOTTOM REGISTER
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS, CHANNEL
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN, CORNER BEAD, CIRCUIT
BREAKER
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER, CONTRACTOR
SUPPLIED & INSTALLED
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS,
CONTRACT DOCUMENTS, CEILING
DIFFUSER
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY, CORNER GUARD
C&G CURB AND GUTTER
CGSFU CERAMIC GLAZED STRUCTURAL FACING
UNITS
CH CHILLER
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL
JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CM² SQUARE CENTIMETER
CM³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNDS CONDENSATE
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CO∠ CARBON DIOXIDE
CODP CLEANOUT W/ DECK PLUG
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT, CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR, CONTRACTION
COORD COORDINATE
COR CONTRACTING OFFICER’S
REPRESENTATIVES
CORR CORRIDOR
CP NON-REINFORCED CONCRETE PIPE
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CR CHAIR, CRASH RAIL
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CS CONCRETE SEALER/SURFACE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS
INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE, CURRENT
TRANSFORMER, COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER, CONTOUR, COOLING TOWER
RETURN
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CW COLD WATER
CWB CAPILLARY WATER BARRIER
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL, DRY BUILT, DIRECT BURIAL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DD DIVERSION DIKE
DEG, ° DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DI DUCTILE IRON
DIA, DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DISTRIBUTION
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM, OR
DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT, STORM DRAINAGE
STRUCTURE
DSGN DESIGN
DW DISHWASHER, DOMESTIC WATER
DWD DRINKING WATER DISPENSER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EAM EXCEPT AS NOTED
EAT ENTERING AIR TEMPERATURE
EF EACH FACE, EXHAUST FAN
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EG EXHAUST GRILLE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
E/P EDGE OF PAVEMEMNT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ER EXHAUST REGISTER
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EVAP EVAPORATIVE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXP JT EXPANSION JOINT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT, FEMALE, FIRE, FUSE,
FILTER
FA FIRE ALARM
FAB FABRIC
FABX FIRE ALARM BOX
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E, FFE FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD, FLAT HEAD SCREWS, FIRE
HYDRANT
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FJ FELT JOINT
FL FLOORLINE, FLOOR, FLASHING, FLOW
LINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
4 WAY FOUR WAY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPH FROST PROOF HYDRANT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR
FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION, FULL SIZE
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FW FIRE WATER
FWC FABRIC WALLCOVERING
G GROUND, GAS LINE, GRAM
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON, GALVANIZED
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR, GLAZED
COATING
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFI GROUND FAULT INTERRUPT
GFMU GROUND FACE MASONRY UNIT
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR GRADE
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GW GROUND WATER
GWB GYPUSM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH, HEIGHT, HUMIDIFIER
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAC HOUSEKEEPING AIDS CLOSET
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE, HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HD HARD DRAWN
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HGSW HORN GAP SWITCH
HID HIGH INTENSITY DISCHARGE
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE, HIGH POINT,
HORSEPOWER
HPS HIGH PRESSURE SODIUM
HQ HEADQUARTERS
HR HOUR
HS HEAT-STRENGTHENED (GLASS) OR HIGH
STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HVY HEAVY
HW HOT WATER, HEAD WALL
HYD HYDRANT
HYDR HYDRAULIC
HZ HERTZ
I INTERSTATE (HIGHWAY) OR MOMENT OF
INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR
INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
IE INVERT ELEVATION
ILLUM ILLUMINATION
IMC INTERMEDIATE METAL CONDUIT
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
INV INVERT
IP INLET PROTECTION
IRBF INDUSTRIAL RESIN BASE FLOORING
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX, JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JT JOINT
JST JOIST
K KILO
KCP KEENE'S CEMENT PLASTER
KD KILN DRIED OR KNOCKED DOWN
KG KILOGRAM
KN KILONEWTON
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L ANGLE, LOUVER, LENGTH, LENGTH OF
CURVE
LA LIGHTING ARRESTOR
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LC LEAD COVERED
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE, LATENT HEAT
RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED, LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
L/S LITERS PER SECOND
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVC LENGTH OF VERTICAL CURVE
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
M METER, MEGA
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MAS MASONRY
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD METAL DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL, MEDIUM
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLO MAIN LUG ONLY
MLWK MILLWORK
mm MILLIMETER
MMP MEMBRANE WATERPROOFING
MO MASONRY OPENING OR MOTOR
OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MP MEDIUM PRESSURE
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
M/S METERS PER SECOND
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA, NON-CORROSIVE
NCOMBL NONCOMBUSTIBLE
NDC NOSE DOWN CURB
NE NORTHEAST
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NRP NON-REMOVABLE
NS NARROW STILE
NTS NOT TO SCALE
NUM NUMERAL
NW NORTHWEST
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCB OIL CIRCUIT BREAKER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE
DIMENSION
OD OUTSIDE DIMENSION OUTSIDE
DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR
INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG, OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSD OPEN SITE DRAIN
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OVHD OVERHEAD
OUT OUTLET
OZ OUNCE
P PIPE, POLE
Pa PASCALES
PA PUBLIC ADDRESS
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON, PULL BOX
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND
CEMENT
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PJF PREFORMED JOINT FILLER
PKG PACKAGE
PL PROPERTY LINE, PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PNT PAINT
PO POST OFFICE, PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRIM PRIMARY
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PRV PRESSURE RELIEF VALVE
PS PULL SWITCH
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, PRESSURE
TREATED, POINT OF TANGENT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC), POINT
OF VERTICAL CURVE
PVG PAVING
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS, RISER, RUBBER
RA RETURN AIR
RAD RADIATOR, RADIUS
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN, REINFORCED
CONCRETE PIPE
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
RED REDUCING
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY, REFRIGERATION
REG REGISTER, REGULATOR
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY, ROOF, RETURN
FAN
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RGS RIGID GALVANIZED STEEL
RH RIGHT HAND
RHC REHEAT COIL
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RI RUBBER INSULATED
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RVT RESILIENT VINYL TILE
RWD REDWOOD
RWL RAIN WATER LEADER
S SECOND, SOUTH, SANITARY, SEWER,
STRUCTURE
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY SEWER
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL, SCHEDULE
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER;
SDG SIDING
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SG SUPPLY GRILLE
SGD SLIDING GLASS DOOR
1PH SINGLE PHASE
SGL SINGLE
SH SHEET
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FL SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKCP SUSPENDED KEENE'S CEMENT
PLASTER
SKLT SKYLIGHT
SL SLOPE
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMH SANITARY MODULE
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SP STATIC PRESSURE, SINGLE POLE
SPC SUSPENDED PLASTER CEILING
SPDT SINGLE POLE DOUBLE THROW
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPST SINGLE POLE SINGLE THROW
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SR SUPPLY REGISTER
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS, STREET, SINGLE THROW
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUP SUPPORT
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SW SWITCH, SIDE WALK
SWBD SWITCHBOARD
SWDR SWING DOOR
SWGR SWITCH GEAR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD, TILE, TOP, TANGENT
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL
TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
TERM TERMINAL
TH TOTAL HEAD (PUMPS)
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRSLD THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK, TOP REGISTER
TRANS TRANSOM, TRANSITION
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH, TUBE STEEL, TOP
OF STEEL, TOP OF STONE, TOP OF
SLAB
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UCF UNDER COUNTER FREEZER
UCR UNDER COUNTER REFRIGERATOR
UGE UNDERGROUND ELECTRIC
UGND UNDERGROUND
UGT UNDERGROUND TELEPHONE
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UNO UNLESS NOTED OTHER WISE
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT, VENT, VALVE
VA VOLT AMPRE
VAC VACUUM
VAR VARIES
VC VARNISH CAMBRIC, VITRIFIED CLAY, VA
SUPPLIED & CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE, VITRIFIED
CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VPI VERTICAL POINT OF INTERSECTION
VPOC VERTICAL POINT OF CURVE
VPOT VERTICAL POINT OF TANGENT
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
VV VA SUPPLIED & INSTALLED
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE, WEST, WIDTH, WASTE, WATER,
WATT, WIRE
W/ WITH
W/O WITHOUT
WA WATT
WARR WARRANTY
WB WET BULB
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD, WINDOW DIMENSION
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WL WATER LEVEL
WLD WELDED
WM WIRE MESH
WOM WALK OFF MATT
WP WATERPROOFING, WEATHERPROOF
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP, WASTE STACK, WATER
SURFACE, WATERSTOP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XFMR TRANSFORMER
XPS EXTRUDED POLYSTYRENE BOARD
(INSULATION)
X-STR EXISTING STRUCTURE
YD YARD
YR YEAR
MATERIALS LEGEND
CONCRETE (SECTION)
GRANULAR FILL
CONCRETE MASONRY UNITS
BRICK
RIGID INSULATION (SECTION)
ACOUSTIC/THERMAL INSULATION (SECTION)
DIMENSIONAL LUMBER
CONTINUOUS (SECTION)
DIMENSIONAL LUMBER BLOCKING
(SECTION)
STEEL (SECTION)
ALUMINUM (SECTION)
WOOD FINISH (SECTION)
LUMBER FINISH (SECTION)
EARTHWORK (SECTION)
STUD WALL (PLAN & SECTION)
EXISTING WALL TO REMAIN (PLAN & SECTION)
DEMOLISHED WALL (PLAN &
SECTION)
MINERAL WOOL INSULATION (SECTION)
RCP SYMBOL LEGEND
CHANDELIER, PENDANT MOUNTED
ACOUSTICAL TILE CEILING (24X24)
ACOUSTICAL TILE CEILING (24X48)
GYPSUM CEILING - PAINTED
RECESSED OR SURFACE MOUNTED LIGHT FIXTURE
LINEAR WALL WASH LUMINAIRE, MOUNTED WITHIN
ARCHITECTURAL COVE
SMOKE DETECTOR
SPEAKER
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
RADIANT HEAT PANEL
EXIT LIGHT
HEAT DETECTOR
HVAC EXHAUST DIFFUSER
LINEAR LUMINAIRE, WALL MOUNTED
(INDICATES DIRECTION OF LIGHT DISTRIBUTION.)
LINEAR LUMINAIRE, PENDANT MOUNTED
STRIP OR TURRET LUMINAIRE, PENDANT
MOUNTED
STRIP OR TURRET LUMINAIRE, SURFACE
MOUNTED
(INDICATES DIRECTION OF LIGHT DISTRIBUTION.)
RECESSED OR SURFACE MOUNTED SQUARE
DOWNLIGHT LUMINAIRE
RECESSED OR SURFACE MOUNTED ROUND
DOWNLIGHT LUMINAIRE
RECESSED OR SURFACE MOUNTED LIGHT FIXTURE
LINEAR METAL CEILINGS / SOFFIT
NOTE: REFER TO ELECTRICAL DRAWINS AND SPECS FOR
ADDITIONAL INFORMATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
-A
-N ew C en tr al _J
A W
A R
R E
N . r vt
/1
/2
:3 :4
P
M
G-101
ABBREVIATIONS AND SYMBOLS 610-303 / 269296
02/28/2018 MT ETD
ISSUED FOR
CONSTRUCTION
Project Director
1700 E 38TH ST, MARION, IN 46953
BUILD PRIMARY CARE CLINIC - PACT
FULLY SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTEL SR ,RA, LEED
AP BD+C
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
ABONMARCHE
750 LINCOLN WAY EAST
SOUTH BEND, IN 46601
574.232.8700
BRAD MOSNESS
FLOOR PLAN GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWING SETS.
2. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY OCCUR IN OTHER
PORTIONS OF THE CONTRACT DOCUMENTS. ALL NOTES ARE TO
BE REVIEWED AND APPLIED TO RELATED BUILDING DOCUMENTS.
3. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE
DISCOVERED FOLLOW PROCEDURES LISTED IN SECTION 01 26 13
REQUESTS FOR INFORMATION (RFI) BEFORE AND/OR DURING
CONSTRUCTION.
4. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT
NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT LIMIT
APPLICATION OF ANY DRAWING OR DETAIL. WHERE SPECIFIC
DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE
DETERMINED, FOLLOW PROCEDURES LISTED IN SECTION 01 26
13 REQUESTS FOR INFORMATION (RFI) PRIOR TO PROCEEDING
WITH WORK.
5. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN ON
DRAWINGS. INFORMATION COMMON TO SEVERAL DRAWINGS
MAY BE NOTED ON ONLY ONCE. CONTRACTORS ARE
RESPONSIBLE FOR ENTIRE SET OF DOCUMENTS.
6. PATCH ALL HOLES IN EXISTING SURFACES AND WHERE
EQUIPMENT HAS BEEN REMOVED OR DEMOLITION HAS
OCCURRED AND PREPARE WALL SURFACES (PATCH, SKIM
COAT, PAINT AND FINISH TO MATCH ADJACENT SURFACES) AS
REQUIRED IN PREPARATION FOR NEW FINISHES SCHEDULED.
PATCH TO MATCH ADJACENT SURFACES IF NOT SCHEDULED.
7. DIMENSIONS ARE TO STRUCTURAL GRIDLINE OR FACE OF
FINISHED WALL UNLESS NOTED OTHERWISE.
8. PROVIDE METAL BACKING AND/OR METAL BLOCKING IN
WALLS AS REQUIRED AT ALL WALL-MOUNTED ITEMS. VERIFY
HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT. REFER TO
METAL BACKING AND BLOCKING DETAILS ON SHEET A-722. AT
EXISTING WALLS, REMOVE WALL MATERIAL TO INSTALL METAL
BACKING/BLOCKING FOR NEW WALL-MOUNTED ITEMS.
9 ALL EXISTING FLOOR AND WALL OPENINGS AND
DEPRESSIONS NOT USED IN THE NEW WORK SHALL BE FILLED
OR CLOSED WITH MATERIALS TO MEET REQUIRED FIRE RATING
AND MATCH ADJACENT FINISHES.
10. DRAWINGS ARE NOT TO BE SCALED. CONTRACTOR TO
VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO
COMMENCING THE WORK.
11. COORDINATE WITH INTERIORS SHEETS FOR CORNER GUARD
AND WALL PROTECTION LOCATIONS AND DETAILS.
12. RADIUS EXPOSED COUNTERTOP CORNERS 2" RADIUS,
TYPICALLY. (2" WHERE 3MM EDGE BANDING, 1" RADIUS AT PLAM
EDGES.) SEE CASEWORK DETAILS.
13. CAULK ALL COUNTERTOPS, BACKSPLASHES AND CABINETS
AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-OUTS
IN COUNTERTOPS.
14. ALL CUTTING AND PATCHING REQUIRED FOR NEW
MECHANICAL AND ELECTRICAL WORK IN ALL EXISTING SPACES
SHALL BE BY THE RESPECTIVE CONTRACTORS.
15. MATCH ALL FINISHED WALL THICKNESS WHERE NEW WALLS
OCCUR IN LINE WITH EXISTING WALLS.
16. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST & NOISE
CONTAINMENT BARRIERS BETWEEN THE WORK AREA & THE
ADJACENT OCCUPIED SPACES.
17. ALL PIPING, CONDUITS, AND RELATED MECHANICAL AND
ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN DRYWALL
AND/OR PLASTER FURRING AS REQUIRED IN FINISHED AREAS
WHETHER SHOWN ON DRAWINGS OR NOT UNLESS OTHERWISE
NOTED.
18. SEAL AROUND ALL MECHANICAL AND ELECTRICAL
EQUIPMENT PENETRATIONS AT RATED WALLS, ABOVE AND
BELOW CEILINGS, WITH A UL APPROVED FIRE-STOPPING
MATERIAL.
19. ALL INTERIOR WALLS WILL BE TYPE 'S' CONSTRUCTION
UNLESS OTHERWISE INDICATED. ALL FRAMING AROUND
COLUMNS WILL BE TYPE 'L2' CONSTRUCTION UNLESS
OTHERWISE INDICATED. REFER TO REGULATORY PLAN SHEETS
GI001 FOR WALL RATINGS.
20. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING
INTERSECT, THE HIGHEST RATED PARTITION TAKES PRECEDENT.
21. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,
DIFFUSERS AND LIGHTS, SPRINKLER HEADS, OCCUPANCY AND
FIRE ALARM DETECTORS TO BE CLEANED IN AREAS OF
CONSTRUCTION.
22. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE RATING
ARE MAINTAINED, REPAIRED AND EXTENDED TO STRUCTURE.
23. ALL THERMOSTAT LOCATIONS TO BE COORDINATED WITH
COR PRIOR TO INSTALLATION.
1. ALL CEILING TO BE 9'-0" AFF UNLESS NOTED OTHERWISE.
2. PROVIDED GYPSUM WALL BOARD & STUD BULKHEADS WHERE
CEILING OF DIFFERENT HEIGHTS ABUT. DO NOT BUILD
BULKHEADS OF ACOUSTICAL CEILING MATERIAL UNLESS
SPECIFICALLY DETAILED.
3. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE
OF DIFFUSERS, RETURN AIR GRILLES, & EXHAUST GRILLES.
SCRIBE CEILING MATERIAL CAREFULLY FOR A TIGHT FIT.
4. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES
OF LIGHTS AND DEVICES. SCRIBE CEILING MATERIAL
CAREFULLY FOR TIGHT FIT.
5. REFER TO FIRE PROTECTION DRAWINGS FOR FIRE SPRINKLER
HEAD LOCATIONS. CENTER HEADS IN CEILING TILE AND
SCRIBE CEILING MATERIALS FOR A TIGHT FIT.
6. REFER TO SPECIFICATIONS FOR GRID SYSTEM, TYPE OF
CEILING MATERIAL.
7. VERIFY CEILING HEIGHTS WITH STRUCTURE, MECHANICAL,
PLUMBING, FIRE PROTECTION, ELECTRICAL AND
CONTRACTOR'S REQUIRED COORDINATION DRAWINGS.
8. ALL GWB SOFFITS, CEILINGS & BULKHEADS RECEIVE PAINT OR
IF ALIGNING W/ ADJACENT WALL, PAINT TO MATCH ADJACENT
@ VERTICAL, PAINT @ UNDERSIDE.
REFLECTED CEILING
PLAN NOTES:
Mark: Revision: Date:
03-19-18
03/19/18Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
Page 2 of 141Page 2 of 141
UP
CBCB
S S
D A
N
N
A P
N
D
D
DA
PP
A P
A
PO
S
D
D
D
D
DO
S O
S
D
D
D
D D
D
N
N
N
N
N
N
N
N
N N
N
N
O S
N
N
N
N
N
N
O S
D
D D
D
D
D
O S
D
D
O S
C R
CR
CR
C R
C R
CR
A P
A P
A P
A P
A P
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
C R
CR
CR
CR
CR
CR
C R
D
D
C R
D H D
H
N
N
N
N
N
N
N
D
D
D
D
CR
OS
C R
C R
CR
CR
BUILDING
EXISTING BUILDING
PLAN
NORTH
D
E
KEY PLAN
CA
X21
X26B
A C GX29
XH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
-A
-N ew C en tr al _J
A W
A R
R E
N . r vt
/1
/2
:3 :5
P
M
GC-101
PROJECT PHASING 610-303 / 269296
02/28/2018 MT ETD
ISSUED FOR
CONSTRUCTION
Project Director
1700 E 38TH ST, MARION, IN 46953
BUILD PRIMARY CARE CLINIC - PACT
FULLY SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTEL SR ,RA, LEED
AP BD+C
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
ABONMARCHE
750 LINCOLN WAY EAST
SOUTH BEND, IN 46601
574.232.8700
BRAD MOSNESS
PHASE 1:
SITE UTILITY RELOCATION & EXISTING BUILDING PREP.
1.0 SECURE SITE.
1.1 RELOCATE SITE UTILITIES. COORDINATE UTILITY SHUT
DOWNS WITH COR PER PROJECT REQUIREMENTS
1.2 PREP EXISTING BUILDING ADDITION:
1.2.1 REMOVE FIRST FLOOR WINDOWS ALONG GRID
x26 FROM xC TO xA, & FIRST FLOOR WINDOW IN STAIR
TOWER.
1.2.2 REMOVE WINDOW AND STONE FOR
TEMPORARY DOOR IN ROOM 152, INSTALL TEMPORARY
SIGNAGE FOR EXITING.
1.2.3 REMOVE WINDOWS IN BASEMENT ALONG GRID
xC FROM x27 TO x29.
PHASE 2:
CONSTRUCT NEW ADDITION & RENOVATION OF EXISTING
SPACE.
2.1 OPEN EGRESS S103A AS SOON AS PRACTICAL, REMOVE
TEMPORARY DOOR AND EXITING AND RESTORE EXISTING
BUILDING.
2.2 AFTER NEW ADDITION IS WEATHER TIGHT, CONTRACTOR
CAN START RENOVATION WITHIN EXISTING SPACE.
1" = 30'-0" F3
PHASING PLAN
PROJECT PHASING NOTES
Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
03-19-18 02/28/201803/19/18
Page 3 of 141Page 3 of 141
391996134
969043
872457
391996126
969061
872457
391996134
872457
391996126
872457
(ASSEMBLY) 122 SF
(ASSEMBLY) 776 SF
(BUSINESS) 13358 SF
1D
1D
1E
1E
1D
1F
1C
1B
1B
1F
P: 40 1/2" R: 36 1/4"
P : 1
/4
R : 3
1/
4"
P: 38 1/2" R: 36 1/4"
P: 38 1/2" R: 36 1/4"
(ASSEMBLY) 128 SF
1I
1I
1I
1I
P: 38 1/2" R: 36 1/4"
P : 3
1/
2" R
: 3
1/ 4"P: 38 1/2"
R: 36 1/4"
P: 38 1/2" R: 36 1/4"
(ASSEMBLY) 390 SF
1G
1H
1H
1I
FEFE
FE
(ASSEMBLY) 307 SF
(ASSEMBLY) 178 SF
(ASSEMBLY) 562 SF
(ASSEMBLY) 281 SF
(ASSEMBLY) 258 SF
(BUSINESS) 17779 SF
(STORAGE) 865 SF
FEC-1
FEC-1
FEC-1
FEC-1
EXISTING
FEC
EXISTING
FEC
TEMPORARY
SIDEWALK
THIS PROJECT HAS BEEN ● INTERNATIONAL BUILDING CODE
DESIGNED UNDER THE 2015 - CURRENT EDITION INCLUDING
REQUIREMENTS OF THE ● NFPA 101 LIFE SAFETY CODE
APPLICABLE CODES: ● ARCHITECTURAL BARRIERS ACT & VA PG18-13 BARRIER FREE DESIGN
STANDARD ● US DEPARTMENT OF VETERANS AFFAIRS DESIGN MANUALS &
STANDARDS
ADDITIONAL REFERENCED CODES, DOCUMENTS
AND STANDARDS AS NOTED IN THE SECTION 01 00 00.
OWNER: Veterans Administration Marion Campus
ARCHITECT: HDR Architecture, Inc.
600 Hennepin Avenue, Ste. 260 Minneapolis, MN 55403
LIFE SAFETY FEATURES:
FIRE SUPPRESSION SYSTEM - SPRINKLED
FIRE EXTINGUISHERS THROUGHOUT
CODE PLAN GENERAL NOTES:
1. SEE ELECTRICAL PLANS FOR EXIT LIGHTING LOCATIONS.
2. SEE FIRE PROTECTION PLANS FOR FIRE SPRINKLER SERVICE.
3. SEE ELECTRICAL FOR FIRE ALARM SERVICE.
PACT:
Occupancy: Group B (NEW BUSINESS) Occupancy Construction Type: Type 1B [II(222)] Sprinklers complying with NFPA 13.
Allowable Area:
B (NEW BUSINESS): UNLIMITED
Actual Area Sq Ft:
Basement: B: 2,988 SF Level 1: B: 13,750 SF Level 1: A: 1,584 SF
TOTAL: 18,322 SF
Allowable Number of Stories: Per Areas in table
B (NEW BUSINESS): UNLIMITED
Allowable Height: (180') 12 STORIES ABOVE GRADE PLANE Actual Number of Stories: 2 (1 ABOVE GRADE PLANE) Actual Height: 12'-7 1/4"
NEW BUSINESS:
Common Path of Travel: >100' Travel Distance to Exits: >300'
STORAGE:
Common Path of Travel: >100' Travel Distance to Exits: >400'
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
(IBC TABLE 601) FOR TYPE I-B (II-222) CONSTRUCTION TYPE
B
Structural Frame 2 Hour Bearing Walls (Exterior) 2 Hour Bearing Walls (Interior) 2 Hour Non Bearing Walls (Exterior 10 < X < 30 ) 0 Hour
Non Bearing Walls (Interior) 0 Hour Floor Construction 2 Hour
(Including supporting beams and joists) Roof Construction* 2 Hour
(Including supporting beams and joists)
*(FUTURE SECOND FLOOR)
Per footnote d at IBC Table 601, ratings can be reduced by 1 hour if an approved sprinkler system is provided.
PLUMBING FIXTURES (IBC CH. 29):
TOTAL OCCUPANT LOAD IS 188
188/2 = 94 EACH:
B OCCUPANCY (TOILETS)-
1 PER 25 FOR FIRST 50, 1 PER 50 FOR REMAINDER
94=2 + 1 = 3 PER GENDER
B OCCUPANCY (LAVORATORIES)-
1 PER 40 FOR FIRST 80, 1 PER 80 FOR REMAINDER
94=2 + 1 = 3 PER GENDER
DRINKING FOUNTAINS: 1 PER 100 = 2
1 SERVICE SINK
LIFE SAFETY SYMBOLS
XXXX PATH OF TRAVEL
(FOR CUMULATIVE DISTANCES REFER
TO SCHEDULE)
EXIT LIGHTING
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHERS
FIRE HOSE CABINETS
DIRECTION OF EGRESS
WIDTH PROVIDED
P: XX"
R: XX"
1A
WIDTH REQUIRED
FEC
FE
FHC
BUILDING SEPARATION
TEMPORARY EXIT PATH FOR STAIR
(STORAGE) 2982 SF
B-A
FE
FE
18A18A
18G18G
18F18F
18B18B18C18C18D18D 18E18E
S003S003
19A19A
21A21A
21B21B
1414 1515 1616 1717
C004C004
C005C005 25A25A
24A24A24B24B24C24C
C003C003
3E3E
S002S002
5B5B
5C5C
5A5A 3A3A
3B3B
3C3C
5D5D
A
A
7B7B
8A8A
999A9A
25A25A
25B25B
S001S001
1111 1212
C001C001
C002C002
(BUSINESS) 17263 SF
PROVIDE GYPSUM BOARD
PARTITION W/ DOOR FOR
DUST CONTROL DURING
DEMOLITION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
-A
-N ew C en tr al _J
A W
A R
R E
N . r vt
/1
/2
:3 :1
P
M
GI-001
LIFE SAFETY PLANS 610-303 / 269296
02/28/2018 MT ETD
ISSUED FOR
CONSTRUCTION
Project Director
1700 E 38TH ST, MARION, IN 46953
BUILD PRIMARY CARE CLINIC - PACT
FULLY SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTEL SR ,RA, LEED
AP BD+C
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
ABONMARCHE
750 LINCOLN WAY EAST
SOUTH BEND, IN 46601
574.232.8700
BRAD MOSNESS
1/16" = 1'-0"
FIRST FLOOR
EGRESS TRAVEL DISTANCES
Path ID Travel Distance
1A 167' - 3 1/8"
1B 75' - 7 1/8"
1C 143' - 6 1/32"
1D 23' - 9 7/32"
1E 192' - 1 13/32"
1F 133' - 7 29/32"
1G 33' - 7 1/32"
1H 246' - 1 1/8"
1I 247' - 0 31/32"
B-A 79' - 3 3/16"
B-B 74' - 0 3/4"
1/16" = 1'-0"
BASEMENT
AREA SCHEDULE (occupancy area)
OCCUPANCY
CLASSIFICATION AREA USE SPACE USE SF PER OCCUPANT OCCUPANCY LOAD
CAPACITY
FACTOR -
STAIRWAYS
REQUIRED
STAIRWAY WIDTH
CAPACITY
FACTOR - OTHER
REQUIRED WIDTH
- OTHER
BASEMENT
(NFPA) BUSINESS 17263 SF NFPA_Business Use: (other than - Air traffic control tower observation levels) Business Use: (other than - Air traffic control tower observation levels)
100 SF 173 0.3 in 51.9 in 0.2 in 34.6 in
(NFPA) STORAGE 6953 SF NFPA_Storage Use: In other than storage and mercantile ccupancies In other than storage and mercantile ccupancies
500 SF 16 0.3 in 4.8 in 0.2 in 3.2 in
24216 SF 189 56.7 in 37.8 in
FIRST FLOOR
(NFPA) ASSEMBLY 390 SF NFPA_Assembly: Less concentrated use, without fixed seating Less concentrated use, without fixed seating 15 SF 27 0.3 in 8.1 in 0.2 in 5.4 in
(NFPA) ASSEMBLY 2612 SF NFPA_Assembly:Waiting spaces Waiting spaces 100 SF 30 0.3 in 9.0 in 0.2 in 6.0 in
(NFPA) BUSINESS 31137 SF NFPA_Business Use: (other than - Air traffic control tower observation levels) Business Use: (other than - Air traffic control tower observation levels)
100 SF 312 0.3 in 93.6 in 0.2 in 62.4 in
(NFPA) STORAGE 865 SF NFPA_Storage Use: In other than storage and mercantile ccupancies In other than storage and mercantile ccupancies
500 SF 2 0.3 in 0.6 in 0.2 in 0.4 in
35004 SF 371 111.3 in 74.2 in
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE
AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH
PATTERNS.
/ 3 stairs = 38" min. 44" / 5 stairs = 15.2" ~ min. 36"
Mark: Revision: Date:
03-19-18Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
Page 4 of 141Page 4 of 141
2 HR RATED PARTITION
BETWEEN EXISTING AND NEW
ADDITION. PARTITION IS
TEMPORARY PER DETAIL BELOW.
TEMPORARY DOOR.
PROVIDE
90 MINUTE RATING.
TEMPORARY DOOR.
PROVIDE 90 MINUTE
RATING.
2 HR RATED PARTITION
BETWEEN EXISTING AND NEW
ADDITION. PARTITION IS
TEMPORARY PER DETAIL BELOW.
TYP.
D5
GI-200
TYP.
D5
GI-200
STICKY MAT: PROVIDE NEW
REGULARLY WHEN OLD IS SPENT
STICKY MAT: PROVIDE NEW
REGULARLY WHEN OLD IS SPENT
NEW ADDITION
RENOVATED PORTION
OF EXISTING BUILDING
NON-RENOVATED
PORTION OF EXISTING
BUILDING
2 HR RATED PARTITION
BETWEEN EXISTING AND NEW
ADDITION. PARTITION IS
TEMPORARY PER DETAIL BELOW.
2 HR RATED PARTITION BETWEEN
EXISTING AND NEW ADDITION. PARTITION
IS TEMPORARY PER DETAIL BELOW.
TEMPORARY DOOR.
PROVIDE 90
MINUTE DOOR.
TEMPORARY DOOR.
PROVIDE 90 MINUTE
RATING.
TYP.
D5
GI-200
STICKY MAT: PROVIDE NEW
REGULARLY WHEN OLD IS SPENT
STICKY MAT:
PROVIDE NEW
REGULARLY WHEN
OLD IS SPENT
WEEKLY CHANGED OR
MORE AS NEEDED
PRE_FILTER
FLEX DUCT
MONTHLY CHANGED
HEPA FILTER
HEPA NEGATIVE AIR
UNIT
PROVIDE STICKY MATS (CHANGED END OF
EVERY SHIFT OR MORE IF NECESSARY TO
MAINTAIN CLEANLINESS).
PROVIDE STICKY MATS (CHANGED END OF
EVERY SHIFT OR MORE IF NECESSARY TO
MAINTAIN CLEANLINESS).
INDICATOR SHALL BE AT 0.01 OR GREATER (VERIFY DAILY). IF NOT VERIFY ALL
OPENING SUCH AS DOOR ARE CLOSED AND/OR CHANGE OUR NEGATIVE AIR
PRE-FILTER.
SUPPLY DUCTS EITHER
KEEP RUNNING OR
COVER WHEN
RUNNING TO KEEP
DUST OUT.
A
V
O
TAPE ALL SERVICES TO
PROTECT AGAINST
CONTAMINATION
E
FIRE EXTINGUISHER ON PORTABLE FLOOR
BRACKET (SHALL REQUIRE MORE THAN
ONE.)
2 HR. TEMPORARY WALL
FLOOR LINE
CEILING SYSTEM AS
SCHEDULED
EXISTING STRUCTURE
/1
F
IN
IS
H
E D
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E
V E
R
IF
Y F
LO
O
R T
O F
LO
O
R H
E
IG
H T
RENOVATED SPRINKLER SYSTEM
REMOVE AND REPLACE
CEILING SYSTEM AT
EXISTING AS NEEDED TO INSTALL
2 HOUR WALL
INFECTION CONTROL 2 HOUR WALL
ICRA SYMBOL LEGEND
INFECTION CONTROL/DUST CONTROL
EGRESS DOOR AND "STICKY MAT"
FLOOR PADS
PATH OF DEMOLITION/TRASH REMOVAL TRAVEL
CONSTRUCTION LIMIT LINE
• IMPLEMENT INFECTION CONTROL RISK ASSESSMENT (ICRA)
PROCEDURES AS PER THE MARION VA MEDICAL CENTER ICRA PLAN
AND AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE
(COR)
• CONTRACTORS SHALL COORDINATE WITH COR FOR ALL
CONSTRUCTION DUST/DEBRIS REQUIREMENTS & MEASURES DURING
DEMOLITION /CONSTRUCTION.
• COORDINATE ALL DEMOLITION/ CONSTRUCTION DEBRIS PATH OF
TRAVEL AND INTERIM LIFE SAFETY MEASURES (ILSM) WITH THE COR.
ALL INTERIOR DOORS THAT LEAD TO THE CONSTRUCTION SITE SHALL
BE POSTED AS PER THE ISLM PLAN.
• THE CONTRACTOR SHALL CONTINUE ALL OPERATIONS (INCLUDING
STORAGE OF MATERIALS) ON GOVERNMENT PREMISES TO AREAS
AUTHORIZED OR APPROVED BY THE COR.
INFECTION CONTROL RISK ASSESSMENT NOTES
PLAN
NORTH
D
E
KEY PLAN
CA
X21
X26B
A C GX29
XH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
-A
-N ew C en tr al _J
A W
A R
R E
N . r vt
/1
/2
:3 :1
P
M
GI-200
INFECTION CONTROL PLAN 610-303 / 269296
02/28/2018 MN MN
ISSUED FOR
CONSTRUCTION
Project Director
1700 E 38TH ST, MARION, IN 46953
BUILD PRIMARY CARE CLINIC - PACT
FULLY SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTEL SR ,RA, LEED
AP BD+C
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
ABONMARCHE
750 LINCOLN WAY EAST
SOUTH BEND, IN 46601
574.232.8700
BRAD MOSNESS
1/16" = 1'-0" B1
BASEMENT
1/16" = 1'-0" E1
FIRST FLOOR
1/2" = 1'-0" C5
TYPICAL CONSTRUCTION LAYOUT - CLASS IV
1/2" = 1'-0" D5
CROSS SECTION AT TEMPORARY WALL
A. THE ONE HOUR FIRE RATED CONSTRUCTION BARRIERS SHALL
BE CONSTRUCTED PRIOR TO BEGINNING OTHER WORK.
B. FIRE PROTECTION SYSTEMS SHALL REMAIN FUNCTIONAL FOR
OCCUPIED AREAS ON THE FLOOR.
C. PROVIDE FIRE EXTINGUISHERS IN CONSTRUCTION AREAS;
REVIEW WITH COR AND VA SAFETY GROUP.
D. MAINTAIN EXIT LIGHTS IN CONSTRUCTION AREA.
E. MAINTAIN NEGATIVE AIR PRESSURE IN CONSTRUCTION AREA AT
ALL TIMES (24/7).WHETHER OCCUPIED OR NOT , THROUGHOUT
DURATION OF PROJECT USING HEPA EQUIPPED AIR FILTRATION
UNITS.
F. CONSTRUCTION AREA SHALL REMAIN ISOLATED FROM THE
OTHER AREAS OF THE MEDICAL CENTER ;NO RETURN AIR OR
EXHAUST SHALL PASS INTO THE AREAS OUTSIDE THE
CONSTRUCTION AREA.
G. REDIRECT ALL MEDICAL CENTER PERSONNEL. PATIENTS AND
VISITORS SO THEY DO NOT EXIT THROUGH THE
CONSTRUCTION AREA .PROVIDE SIGNS ON DOORS INTO THE
CONSTRUCTION AREA THAT READS: "CONSTRUCTION AREA-DO
NOT ENTER".
H. GENERAL CONTRACTOR SHALL MAINTAIN DAILY LOGS AND
KEEP A CURRENT HOT WORK PERMIT ON SITE.
I. TACKY MATS SHALL BE PLACED AT ALL DOORS INTO THE
CONSTRUCTION AREA AND SHALL BE MONITORED TO MAKE
SURE THEY REMAIN EFFECTIVE.
J. MAINTAIN A CLEAN AND ORDERLY CONSTRUCTION AREA .ALL
DEBRIS REMOVAL SHALL BE IN COVERED CARTS AND/OR
CONTAINERS.
K. OBTAIN INFECTION CONTROL PERMIT PRIOR TO BEGINNING
WORK.
L. ISOLATE HVAC SYSTEM WITHIN CONSTRUCTION AREA TO
PREVENT CONTAMINATION OF EXISTING DUCT SYSTEM.
M. SEAL ALL HOLES,PUNCTURES,AND PENETRATIONS FROM PIPES
AND/CONDUITS APPROPRIATELY AND IMMEDIATELY TO
MAINTAIN DUST PROTECTION AND NEGATIVE AIR PRESSURE.
N. CONSTRUCT ANTEROOM AT ENTRANCES TO CONSTRUCTION
AREAS AND REQUIRE ALL CONSTRUCTION PERSONNEL TO
PASS THROUGH THIS ROOM TO BE VACUUMED WITH HEPA
VACUUM CLEANER PRIOR TO LEAVING THE SITE.
O. CONSTRUCTION BARRIERS…
This is the start of the file's text. The full file is on GovTribe.