36C25018B0109-005.pdf

PDF 54 KB Posted

Attached to
Install ADA Compliant Access 515-14-104 Federal contract opportunity
Solicitation number
36C25018B0109
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25018B0109 150048_170714_SubmittalLlog.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Install ADA Compliant Access 515-14-104, newest first.
File Type Posted
36C25018B0109-00005000.docx DOCX document
36C25018B0109-00005001.pdf PDF
36C25018B0109-00004000.docx DOCX document
36C25018B0109-00003000.docx DOCX document
36C25018B0109-00002001.pdf PDF
36C25018B0109-00002000.docx DOCX document
36C25018B0109-00001000.docx DOCX document
36C25018B0109-00001001.docx DOCX document
36C25018B0109-00001002.pdf PDF
36C25018B0109-004.pdf PDF
36C25018B0109-008.docx DOCX document
36C25018B0109-002.pdf PDF
36C25018B0109-003.pdf PDF
36C25018B0109-010.docx DOCX document
36C25018B0109-009.docx DOCX document
36C25018B0109-006.doc DOC document
36C25018B0109-001.docx DOCX document
36C25018B0109-007.docx DOCX document
36C25018B0109-000.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Section 01 33 23 SUPLEMENT ADA Compliant Access to Various Building Battle Creek VA Medical Center VA Project: 515-14-104

01 33 23 SUPPLEMENT - 1/8

SUBMITTAL LOG

Refer to specification sections for details of required submittals.

S E

C T

IO

N

U M

B

R

C T

IO

N

T

IT

L

O

P

O D

U C

T D

A T

A

H

O P

D R

A W

IN

G

D

S

IG

N C

R

IT

E

IA

M P

L

S T

R E

P O

R

Q

A L

IF

IC

A T

IO

C

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements X

01 33 23 Shop Drawings, Product Data, and Samples

X

01 35 26 Safety Requirements X X

01 45 29 Testing Laboratory Services

01 57 19 Temporary Environmental Controls

01 74 19 Construction Waste Management

01 81 11 Sustainable Design Requirements

X X

DIVISION 02 – EXISTING CONDITIONS

02 41 00 Demolition X

DIVISION 03 – CONCRETE

03 30 00 Cast-in-Place Concrete X

DIVISION 04 – MASONRY

04 05 13 Masonry Mortaring X X X

04 05 16 Masonry Grouting X

04 20 00 Unit Masonry X X

01 33 23 SUPPLEMENT - 2/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

DIVISION 05 – METALS

05 12 00 Structural Steel Framing

05 21 00 Steel Joist Framing X X X

05 31 00 Steel Decking X X X

05 40 00 Cold-Formed Metal Framing

05 50 00 Metal Fabrications X X

DIVISION 06 – WOOD,PLASTICS AND COMPOSITES

06 10 00 Rough Carpentry X

06 16 63 Sheathing X X

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 21 13 Thermal Insulation X

07 22 00 Roof and Deck Insulation

07 24 00 Exterior Insulation- Finish System

07 25 00 Weather Barriers X

07 31 13 Asphalt Shingles X X

07 54 16 Ethylene Interpolymer (KEE) Roofing

X X X X

07 60 00 Flashing and Sheet Metal

07 71 00 Roof Specialties X X X

07 84 00 Firestopping X X

07 92 00 Joint Sealants X X X

01 33 23 SUPPLEMENT - 3/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

DIVISION 08 - OPENINGS

08 41 13 Aluminum-Framed Entrances and Storefronts

08 42 29.23 Sliding Automatic Entrances

08 71 00 Door Hardware X X

08 71 13 Automatic Door Operators

08 80 00 Glazing X X

DIVISION 09 – FINISHES

09 05 16 Subsurface Preparation for Floor Finishes

09 22 16 Non-Structural Metal Framing

09 29 00 Gypsum Board X

09 65 13 Resilient Base and Accessories

09 65 19 Resilient Tile Flooring X X X

09 67 23.60 Resinous (Urethance and Epoxy Mortar Flooring

09 91 00 Painting X X X

DIVISION 10 – SPECIALTIES

10 26 00 Wall and Door Protection

01 33 23 SUPPLEMENT - 4/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

DIVISION 21- FIRE SUPPRESSION

21 13 13 Wet-Pipe Sprinkler Systems

X X

DIVISION 22 – PLUMBING

22 05 11 Common Work Results for Plumbing see individual sections for requirements

22 07 11 Plumbing Insulation X X X

22 14 00 Facility Storm Drainage X X

DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

23 05 11 Common Work Results for HVAC see individual sections for requirements

23 05 41 Noise and Vibration Control for HVAC Piping and Equipment

23 05 93 Testing, Adjusting, and Balancing for HVAC

X X X

23 07 11 HVAC and Boiler Plant Insulation

23 09 23 Direct-Digital Control System for HVAC

23 21 13 Hydronic Piping X X X X

23 21 13.55 Hydronic Slab Heating and Snow Melting Systems

23 21 23 Hydronic Pumps X X

23 22 13 Steam and Condensate Heating Piping

23 22 23 Steam condensate Pumps

01 33 23 SUPPLEMENT - 5/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

23 25 00 HVAC Water Treatment X X X X

DIVISION 26 – ELECTRICAL

26 05 11 Requirements for Electrical Installations see individual sections for requirements

26 05 19 Low-Voltage Electrical Power Conductors and Cables

26 05 26 Grounding and Bonding for Electrical Systems

26 05 33 Raceway and Boxes for Electrical Systems

26 09 23 Lighting Controls X X X

26 27 26 Wiring Devices X X X

26 29 11 Motor Controllers X X X

26 29 21 Enclosed Switches and Circuit Breakers

26 51 00 Interior Lighting X X X

26 56 00 Exterior Lighting X X X

DIVISION 27 – COMMUNICATIONS

27 05 11 Requirements for Communications Installations see individual sections for requirements

27 05 26 Grounding and Bonding for Communications

27 05 33 Raceways and Boxes for Communications

27 10 00 Structured Cabling X X

01 33 23 SUPPLEMENT - 6/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

27 51 16 Public Address and Mass Notification

X X X X X X

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 05 00 Common Work Results for Electronic Safety and Security see individual sections for requirements

28 05 13 Conductors and Cables for Electronic Safety and Security

28 05 26 Grounding and Bonding for Electronic Safety and Security

28 05 28.33 Conduits and Backboxes for Electronic Safety and Security

28 31 00 Fire Detection and Alarm

DIVISION 31 – EARTHWORK

31 20 00 Earthwork X X X

31 23 23.33 Flowable Fill X X X

DIVISION 32 – EXTERIOR IMPROVEMENTS

32 05 23 Cement and Concrete for Exterior Improvements

X X X X X

32 17 23 Pavement Markings X X

32 90 00 Planting X X X X X

01 33 23 SUPPLEMENT - 7/8

S E

C T

M

B

C T

IO

N

T

IT

O D

U C

T D

A

O P

D R

A W

IN

S

IG

N C

R

IT

E

M P

L

S T

R E

P O

R

A L

IF

IC

A T

IO

H E

D U

L

R T

IF

IC

A T

IO

A N

S /R

E P

O R

S T

A

IN

A B

O S

E O

DIVISION 32 – UTILITIES

33 46 13 Foundation Drainage X

END OF SECTION

01 33 23 SUPPLEMENT - 8/8

THIS PAGE WAS INTENTIONALLY LEFT BLANK

File details come from the government source that posted it.