Drawing Set.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24922R0038
About this file
This pre-solicitation notice provides advance information about an upcoming federal contract opportunity to renovate a women's health clinic building at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The project number is 621-17-110 with an estimated value between $1-2 million. The renovation work is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation is expected to be released on March 9, 2022 with responses due around April 8, 2022. The contract will be awarded using lowest price technically acceptable procedures. Offerors must be verified in the VIP and SAM databases and submit evidence of VETS4212 enrollment. The work involves renovating the women's health clinic building and connecting new plumbing fixtures to existing water, waste and vent systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24922R0038 0002.pdf | ||
| Price Proposal Template.xlsx | XLSX spreadsheet | |
| 36C24922R0038 0001.pdf | ||
| 36C24922R0038_1.pdf | ||
| PPQ - Project 621-17-110.pdf | ||
| General Conditions Breakout.xlsx | XLSX spreadsheet | |
| EMR 36C24922R0038.pdf | ||
| WD TN20220111 2-25-22.pdf | ||
| Specs Combined Set.pdf | ||
| RFI Form - 36C24922R0038.pdf | ||
| 36C24922R0038.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 4:
A
M
GI001
COVER SHEET
1 2KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
MOUNTAIN HOME VAMC
VA PROJECT NO. 621-17-110
RENOVATE WOMEN'S HEALTH
CLINIC BLDG. 160
DRAWING LIST
SHEET # SHEET NAME DWG OF DWG
GENERAL
GI001 COVER SHEET 1 2
GI101 SECOND FLOOR LIFE SAFETY PLAN 2 2
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS, NOTES, PARTITION TYPES AND DETAILS 1 7
AD101 SECOND FLOOR DEMOLITION / ICRA PLAN 2 7
AD111 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN 3 7
AI101 RENOVATION PLAN 4 7
AI111 REFLECTED CEILING PLAN 5 7
AI201 INTERIOR ELEVATIONS, DOOR SCHEDULE, ELEVATION AND DETAILS 6 7
AI401 ENLARGED VIEWS AND DETAILS 7 7
FIRE PROTECTION
F-001 FIRE PROTECTION GENERAL INFORMATION 1 3
FD-101 SECOND FLOOR FIRE SUPPRESSION PLAN - DEMOLITION 2 3
F-101 SECOND FLOOR FIRE SUPPRESSION PLAN - NEW WORK 3 3
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 4
PD-101 SECOND FLOOR PLUMBING DEMOLITION PLAN 2 4
P-101 SECOND FLOOR DOMESTIC WATER,DRAIN,WASTE, AND VENT PLAN 3 4
P-501 PLUMBING DETAILS 4 4
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 9
MD101 SECOND FLOOR HVAC DEMOLITION PLAN 2 9
MH101 SECOND FLOOR HVAC NEW PLAN 3 9
MH102 SECOND FLOOR CEILING PLAN 4 9
MP101 SECOND FLOOR MECHANICAL PIPING PLAN 5 9
M-501 MECHANICAL DETAILS 6 9
M-502 MECHANICAL DETAILS 7 9
M-503 MECHANICAL CONTROLS 8 9
M-601 MECHANICAL SCHEDULES 9 9
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 7
ED101 SECOND FLOOR POWER DEMOLITION PLAN 2 7
ED102 SECOND FLOOR LIGHTING DEMOLITION PLAN 3 7
EP101 SECOND FLOOR POWER PLAN 4 7
EL101 SECOND FLOOR LIGHTING PLAN 5 7
E-501 ELECTRICAL DETAILS 6 7
E-601 PANEL SCHEDULES 7 7
TECHNOLOGY
T-001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS 1 4
T-101 SECOND FLOOR TECHNOLOGY PLAN 2 4
T-102 SECOND FLOOR SECURITY PLAN 3 4
T-501 TECHNOLOGY DETAILS 4 4
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, RISER AND DETAILS 1 2
FA101 SECOND FLOOR FIRE ALARM PLAN 2 2
CAMPUS MAP
VICINITY MAP
N
N
PROJECT LOCATION
VA CAMPUS
DocuSign Envelope ID: 4AA3B220-56EE-4750-88A6-9541AEA0B6DA
3/28/2019
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:LAMINATE TILE
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:CERAMIC TILE
FF:VCT
FF:CONCRETE
FF:VCT
FF:VCT
FF:LAMINATE TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT FF:VCT FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CARPET
FF:VCT
FF:CERAMIC TILE
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT FF:VCT FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCTFF:VCTFF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE FF:CERAMIC TILE
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:CERAMIC TILE
FF:LVT
FF:VCT
FF:VCT
FF:CARPET
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:LAMINATE TILE
FF:CERAMIC TILE
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:LAMINATE TILE FF:LAMINATE TILE
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:LVT
FF:VCT
FF:VCT
FF:WSF
FF:VCT
FF:WSF
FF:WSF
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT FF:VCT
FF:VCT
FF:WSF
FF:WSF
FF:VCT
FF:VCTFF:WSF
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:LVT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:LVT
FF:LVT
FF:LVT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:VCT
FF:CERAMIC TILE
FF:CERAMIC TILE
FF:VCT FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
N207
N268
P238
P244
L201
N200
NO-1
P202
P200
L202
P4
P3
N202
N200A
N204
N204
N231
N265A
N267
N276
N222
N220
N218
N224
N226
N228
N230
N270
N234
N235
N233
N233A
N229
N229A
N227
N227A
N231A
N225A
N225N223E
P223D
P223C
N223B
N223A
N221E
N221D
N221C
N221B
N221A
N219
N217
N202
N201
NO-3
N205N203
N209
N211
N213
N215
P244S
P244R
P244Q
P244P
P244N P244M P244L P244K
P244J
P244H
P244GP244FP244E
P244D
P244C
P244B
P244A
P242
P240
P265
P263
P236
P238Q
P238P
P238N
P238M
P238L
P238K
P238JP238HP238G
P238A
P238B
P238C
P238D
P238E
P238F
P201
P1
P2
P230 D
P230 B
P230 A
P232
P230 C
P230
P230 E
P255
P235
P255 A
P253
P237
P239
P241
P243
P251
P234 B
P234 A
P234
P234 N
P234 M
P234 L
P234 K
P234 D
P234 E
P234 F
P234 G
P234 H
P234 I
P234 C
P236 A
P236 B
NO-6
P234 J
N232
N282
N282C
N282B
N282A
N255
N255P
N255B
N255C
N255D
N255E
N255F
N255N
N255M
N255L
N255K
N255J
N255H N253
N251
N249B
N249A
N249
N247DN247E
N247C
N247F
N247G
N247B
N247A
N247H
N247J
N247
N254
N256
N246
N244
N258
N242
N240
N270
N260
N238
N255Q
N255A
N247K
P233
P257
P259
P219
P203 A
P231
P229
P227
P225
P223
P261
P221
P217
P215
P213
P211
P209 P207 P205
P203
P222
P224
P226
P228 B
P228 A
P228 S
P228 R
P228 Q
P228 P
P228 N
P228 M
P228 L
P228 K
P228 J
P228 H
P228 G
P228 F
P228 E
P228 D
P228 C
P228
N206
N267A
N265
N234A
BALCONY
PCMHI
EXAM
CORRIDOR
CORRIDOR
CORRIDOR
SIG
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
PACT CLINIC
SUITE
STORAGE
ALCOVE
BALCONY
PACT CLINIC
SUITE
CORRIDOR
VEST
CORRIDORCORRIDOR
MED
PREP
STAIR
TOILET
FEMALE
TOILET
CHECK-IN
AREA
ELEVATOR
LOBBY
ELEVATOR
ELEVATOR
OUTPATIENT
LAB
PROCESSING
OFFICE
VENDING
VEND
EXAM RM
PACT
OFFICE
TOILET
EXAM
SOIL
UTILITY
STORAGE/MED
HAC
ELECTRICAL
CLEAN
UTILITY
SCI CO-ORDR
OFFICE
MAIL RM
NFS
OFFICE
EXAM
MULTI-
PURPOSE
RM/KIT
MOVE
COORDINATOR
WAITING
ROOM
TOILET
TOILET
OFFICE
EXAM
EXAM
EXAM RMEXAM
EXAM
TOILETPOLYTRAUMA
SOCIAL
WORKER
EXAM
EXAM
EXAM
BALCONY
TOILET
EXAM
EXAM
EXAM
EXAM
LAB
TOILET
DOM ADMISSIONS
MALE
TOILET
STAIR
WHEEL CHAIR STORAGETOILET
EXAM
EXAM
EXAM
EXAM
EXAM 1
EXAM 3
RN 2
EXAM 6
RN 4 M.D. 1 M.D. 2
LPN
M.D. 4
M.D.3
EXAM 8EXAM 7RN 3
EXAM 5
EXAM 4
EXAM 2
SCALE
RN. 1
FEMALE
MALE
STAFF
LOUNGE
CONFERENCE
ANCILLARY STAFF
STORAGE
ALCOVE
EXAM 1
EXAM
RN. 2
RN. 3
EXAM 6
M.D. 1
M.D. 2M.D. 3SOCIAL WORKER
SCALE
RN. 1
EXAM 2
EXAM 4
EXAM 5
PHARM D.
LPN
PATIENT ADOVCATE
ELEVATOR
ELEVATOR
LPN NOOK
RN
EXAM
CLERK
MD
WAIT
EXAM
CLEAN LINEN
ELECTRICAL
TELEPHONE TRIAGE
HAC
STAFF BATH
MULTIPURPOSE RM
MULTIPURPOSE RM
MALE TOILET
FEMALE TOILET
EXAM
EXAM
CLERK / WAIT
EXAM
EXAM
EXAM
EXAM
MD
RN
BALCONY
RN
MD
LPN
RN
LPN NOOK
PHARM D
STORAGE
STAIR
MD
NFS
OFFICE
WAITING ROOM
OFFICE
OFFICE
OFFICE
WAITING
ROOM
CLERKS
EXAM
ROOM
PATIENT
TOILET
STRETCHER
EXAM ROOM
EXAM
ROOM
PATIENT
TOILET
LPN
OFFICE
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
SHARED
OFFICE
OFFICE
SUPPORT
OFFICE
M.H.
OFFICE
STAIRS
TOILET
MALE
TOILET
FEMALE
BREAK
ROOM
EXAM
ROOM
PATIENT
TOILET
SOCIAL
WORKER
MD
OFFICE
EXAM
ROOM
SCALES
NURSE
TRIAGE
BALCONY
LPN
OFFICE
CLERK
WAITING
ROOM
SUPPLY
ROOM
SERVICE ELEVATOR
LOBBY
SERVICE
ELEVATOR TOILET
HAC
CLEAN
UTILITY
TRASH
ROOM
SOILED
UTILITY
CRASH
CART
SPS
STORAGE
ELEC.
ROOM
CORRIDOR
SCALES
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
OFFICE
SUPPORT OFFICE
OFFICE
OFFICE
WAITING ROOM
OFFICE
DATA COMM.
OFFICE
MEDS/STORAGE
SOILED UTILITY
OVERFLOW WAITING
CLEAN UTILITY
OFFICE
MECHANICAL/ELECT.
HAC HSKPG
STAFF TOILET
STAFF TOILET
OFFICE OFFICE
CLERK
NURSE MANAGER
OFFICE
OFFICE
EXAM 4.1
EXAM 4.2
EXAM 1.1
EXAM 1.2
RN 1
EXAM 2.1
EXAM 2.2
EXAM 3.1
EXAM 3.2
RN 3
RN 2
M.D. 3
LPN 1, 2, 3, 4
M.D. 2
M.D. 1
RN 4
M.D. 4
SUITE
CORRIDOR
CLERKS
PACT
OFFICE
SUPPLY
PACT
4 TEAMS
PACT
1 TEAM
PACT
3 TEAMS
PACT
3 TEAMS
PACT
4 TEAMS
PACT
GERI-PACT
SCI CLINIC
PACT
2 TEAMS
UP
DN
UP
DN
UP
DN
TRAVEL DISTANCE = 54'-7"
TRAVEL DISTANCE = 57'-1"
FEC
FEC FEC
FEC
FEC
FEC
LIMIT OF WORK
TO
S
TA
IR
S
TO STAIRS
FIRE EXTINGUISHER CABINET*
EGRESS PATH
TOTAL TRAVEL DISTANCE TO
AN EXIT (NFPA 101.39.2.6)
TRAVEL DISTANCE
(NFPA 101.39.2.5.3 exc. l)
FEC
300'-0" MAX
100'-0" MAX
* ALL EXISTING FEC TO REMAIN.
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 4:
A
M
GI101
SECOND FLOOR LIFE SAFETY PLAN
2 2KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
0 8 16 32
NORTH
PLAN
N
SCOPE OUTLINE
SECOND FLOOR KEY PLAN
SCALE: NO SCALE
Scale: 1/16" = 1'-0"1 SECOND FLOOR LIFE SAFETY PLAN
CODE INFORMATION:
PROJECT NAME: AE RENOVATE WOMEN'S
HEALTH BLDG. 160
PROJECT ADDRESS: JAMES H QUILLEN LAMONT &
VETERANS WAY, BLDG. 205
MOUNTAIN HOME, TN 37684
APPLICABLE CODES: VA DESIGN MANUAL:
FIRE PROTECTION (12/2015)
NFPA 101 (2018) LIFE SAFETY
CODE
AMERICANS WITH DISABILITIES
ACT (ADA)
OCCUPANCY CLASSIFICATION (VA FP DES. MAN.
SECTION 4.1)
BUSINESS OCCUPANCY BUILDING: SPRINKLERED
LIFE SAFETY LEGEND:
AFF ABOVE FINISHED FLOOR
ACP/APC ACOUSTIC CEILING PANEL/
ACOUSTIC PANEL CEILING
ACT ACOUSTIC(AL) TILE
ADJ ADJUSTABLE
ADT'L ADDITIONAL
AGG AGGREGATE
ALT ALTERNATE
AL ALUMINUM
APPROX APPROXIMATE(LY)
ASPH ASPHALT
AUTO AUTOMATIC
B/O BOTTOM OF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRG BEARING
CENTERLINE
C/C CENTER TO CENTER
CJ CONTROL JOINT
CLL CONTRACT LIMIT LINE
CEM CEMENT(ITIOUS)
CMU CONCRETE MASONRY UNIT
CLG CEILING
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
CTR CENTER(ED)
DF DRINKING FOUNTAIN
DS DOWNSPOUT
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DET/DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DWG(S) DRAWING(S)
E EAST
EC ELECTRICAL CONTRACTOR
EHO ELECTRICAL HOLD OPEN
EJ EXPANSION JOINT
EW EACH WAY
EA EACH
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FFE FINISH FLOOR ELEVATION
FV FIELD VERIFY
FEC FIRE EXTINGUISHER CABINET
FDN FOUNDATION
FIN FINISH
FLSHG FLASHING
FLR FLOOR
FRMG FRAMING
FT FOOT/FEET
FTG FOOTING
GC GENERAL CONTRACTOR
GA GAUGE
GALV GALVANIZED
GEN GENERAL
GYP GYPSUM
HM HOLLOW METAL
HDWR HARDWARE
HOL HOLLOW
HOR HORIZONTAL
HT HEIGHT
HVAC HEATING/VENTILATION/AIR
CONDITIONING
IDPH ILLINOIS DEPARTMENT OF
PUBLIC HEALTH
ID INSIDE DIAMETER
IN INCH
INCL INCLUDING
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
LAV LAVATORY
LB(S) POUND(S)
L/S LANDSCAPE
LT LIGHT
MO MASONRY OPENING
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NOM NOMINAL
OC ON CENTER
OD OUTSIDE DIAMETER
O TO O OUT TO OUT
OPNG OPENING
OPP OPPOSITE
OVHD OVERHEAD
PEB PRE-ENGINEERED BUILDING
PJF PREFORMED JOINT FILLER
PT PRESSURE TREATED
PERIM PERIMETER
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNT PAINT
PR PAIR
PTD PAINTED
PWR POWER
RB RUBBER BASE
RD ROOF DRAIN
RO ROUGH OPENING
RAD RADIUS
REC RECESSED
REINF REINFORCED
REQ'D REQUIRED
REV REVISED (REVISION)
RM ROOM
S SOUTH
SB SPLASH BLOCK
SF SQUARE FEET
SS STAINLESS STEEL
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T&G TONGUE AND GROOVE
T/O TOP OF
TELE TELEPHONE
TRTD TREATED
TS TUBE STEEL
TYP TYPICAL
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
VERT VERTICAL
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WWF WELDED WIRE FABRIC
WD WOOD
WH WATER HEATER
WT WEIGHT
CL
DEMOLITION KEYNOTE
WALL TYPE
DOOR NUMBER
TYPICAL KEYNOTE CEILING/ SOFFIT
HEIGHT
MATL
1'-0"#
NORTH
PLAN
NORTH ARROW
N
NORTH
TRUE
CG
CORNER GUARD
XXXXX ACCENT WALL FINISH
XXXX
GENERAL ARCHITECTURAL NOTES
1. KEY NOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT GENERAL WORK AND DO NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS.
2. REMOVE EXISTING CONSTRUCTION AS DESIGNATED HEREIN AND CLEAR AREA OF DEBRIS PRIOR TO
PROCEEDING WITH NEW CONSTRUCTION.
3. EXISTING EQUIPMENT REMOVED SHALL BE PROPERLY DISPOSED OFF MEDICAL CENTER GROUNDS.
4. PATCH WALL OPENING SHALL MATCH THE INTEGRITY OF ADJACENT CONSTRUCTION UNLESS
INDICATED OTHERWISE.
5. NOTIFY COR OF ANY DEMOLITION REQUIRED AND NOT INDICATED FOR INSTALLATION OF ELECTRICAL OR DATA ITEMS. AFTER SUCH DEMOLITION AND INSTALLATION, PARCH OR REPLACE MATERIALS AND
FINISHES TO MATCH EXISTING.
6. THE INFORMATION CONTAINED IN THESE DEMOLITION DOCUMENTS DEFINES GENERAL SCOPE ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION
REQUIRED FOR THE COMPLETION OF THE PROJECT.
7. REFER TO THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION REGARDING DEMOLITION OF
ELECTRICAL SYSTEMS.
8. BEFORE THE START OF WORK, IDENTIFY ANY REQUIRED DEMOLITION BEYOND THE IDENTIFIED PROJECT SCOPE WHETHER ABOVE, BELOW OR OUTSIDE PROJECT AREA. NOTIFY AND COORDINATE WITH THE COR, PROVIDE DEMOLITION OF THESE AREAS AND PATCH THE SAME AS A PART OF THE
SCOPE OF THE PROJECT.
9. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE. DISCOVERY OF UTILITIES OR CONDITIONS LOCATED DIFFERENTLY FROM THAT INDICATED OR THAT ARE NOT IDENTIFIED. SHALL BE REPORTED TO THE CONTRACTING OFFER.
GENERAL ARCHITECTURAL DEMOLITION NOTES
CEILING
STEEL STUDS (3 5/8")
(UNO)
UNDERSIDE OF STRUCTURE
GYP WALL BD (5/8")
SEALANT
FLOOR SLAB
SEALANT
NOTE: SEAL ALL
PENETRATIONS WITH
SEALANT
TYPE 3.0*
SCALE: 1-1/2"=1'-0"STC-49 SA870717
3/ 8"
1"
2.0 SIMILAR
WITH 2 1/2" STUDS
4.0 SIMILAR
WITH 4" STUDS
1.0 SIMILAR
WITH 1 5/8" STUDS
6.0 SIMILAR
WITH 6" STUDS
SOUND ATTENUATION
INSULATION
8.0 SIMILAR
WITH 8" STUDS BASE AS SCHEDULED
EXTEND STUDS
TO
STRUCTURE
AND SECURE
*DOES NOT HAVE SOUND ATTENUATION INSULATION
16 SQ. INCH MAX AT EACH
OPENING.
RATED GYP WALL BD
ADJACENT ELECTRICAL BOXES - RATED WALLS
SCALE: NTS
SEAL BOXES TIGHT WITH
JOINT COMPOUND
2 FEET MIN.
*MAXIMUM OPENING PER 100 SQ.
FT. IS LIMITED TO 100 SQ. INCHES*
DATA /
ELEC
BOX
DATA /
ELEC
BOX
SCREWS AS REQ'D
BOXED HEADER DETAIL
SCALE: NTS
BOXED HEADER,
SIZE AND GAGE AS
REQ'D
INSERT INSULATION INTO
BOX WHEN LOCATED ON
EXTERIOR WALL - R
VALUE OF INSULATION TO
MATCH ADJACENT WALL
TRACK PIECE, SIZE
AND GAGE AS
REQ'D. SCREW TO
JAMB AND LINTEL
AS REQ'D
SCREWS AS REQ'D
JAMB, SIZE AND
GAGE AS REQ'D
SUPPORT CLIP W/
SCREWS AS REQ'D
3/8
FLOOR SLAB
FIRE SEALANT
STEEL STUDS (3 5/8")
@ 16" ON CENTER
FIRE RATED GYP
WALL BOARD (5/8")
CEILING
NOTE: FIRESTOP
ALL PENETRATIONS
TYPE 3.1 (1-HR)
SCALE: 1-1/2"=1'-0"
STC-49 SA870717
UL-U419 1 HOUR
3/ 8"
4.1 SIMILAR
WITH 4" STUDS
6.1 SIMILAR
WITH 6" STUDS
GLASS FIBER OR MINERAL
WOOL INSULATION
M
AX
1/
4"
FIRE SEALANT
2" M
IN
/ 6
" M
AX
FIRE RATED GYP
WALL
BD (5/8")
UNDERSIDE OF FLOOR OR
ROOF ASSEMBLY PER U.L.
DESIGN NUMBER
BASE AS SCHEDULED
EXTEND STUDS
TO STRUCTURE
AND SECURE
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
ELEVATION
0'-0"
ROOM
NAME
101A
0 4 8 16
1-1/2"
DIAMETER
GRAB BAR
TOILET
TISSUE
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
FIXTURE
TOILET
FIXTURE
TOILET
TISSUE
DISPENSER
1-1/2"
DIAMETER
GRAB BAR
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
ACCESSIBLE TOILET PAPER TOWEL DISPENSER/
WASTE RECEPTACLE
TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
2' -5
" M
IN
2' -1
0" M
AX
3' -4
" M
AX
4' -0
" M
AX6'
-8 " A
.F .F
1'-6"
9"
5'-0" CLEAR
3'-0" 6"
9"
3'-0"
1' -7
" 3' -0
1' -6
3'
-4
1'-0" 3'-6"
2'-4"
5'-0" CLEAR
MIN
8"
MAX
6"
M
IN9"
2' -3
" M
IN
2' -5
" M
IN
2' -1
0" M
AX
17" MIN
TYPICAL URINAL
MOUNTING
CLEAR
15"
CLEAR
15"
1' -5
"3' -8
" M
AX
TYPICAL TOILET NON-ACCESSIBLE
TOILET
TISSUE
DISPENSER
2'-9"
2' -1
0"
TOILET
FIXTURE
1'-6"
O F
R
IM
1' -3
" T O
P
4' -0
W H
ER
E
H .C
AC
C
ES
S R
EQ
'D
OF DOOR WIDTH WHEN
ON WALL BEYOND
DOOR
NURSE
CALL
DOME
LIGHT
TOWEL BAR
ACCESSIBLE
ROBE/COAT HOOK
ROBE/COAT
HOOK
TELEVISION
OUTLET
WALL MOUNTED TV
(UNO)
COAT RACK / COAT HOOK NURSE CALL DEVICESTOILET ACCESSORIES
HAND DRYER
3' -4
5' -9
4' -0
6"
5' -6
" T
YP
, 4 '-6
" M
AX
7' -0
3' -0
FO
R
S
TA
N D
IN
G
5' -5
O
.C
TELEVISION
OUTLET
FO
R
S
EA
TE
D
4' -0
" O .C
PAPER TOWEL
DISPENSER
4' -0
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
ELECTRICAL CABINET
6' -6
DUPLEX
OUTLET
SWITCH
THERMOSTAT
TELEPHONE
OR DATA
OUTLET
FIRE ALARM
PULL
INTERCOM
STATION
DUPLEX
OUTLET
COMPUTER
TERMINAL
4' -0
1' -6
FIRE ALARM
CHIME WITH
VISUAL
ALARM LIGHT
FIRE ALARM
PULL STATION
FIRE ALARM
ANNUNCIATOR
FIRE ALARM
5' -0
3' -6
7' -0
"OR DOOR FRAME
3" TO CORNERGUARD
CORNERGUARD
DIAPER CHANGING
STATION
2' -8
" M
IN
2' -1
0" M
AX
MISC. WALL DEVICES
1' -3
/2
3/ 4"
TO
B
O
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C E
O F
M
IR
R O
R
WALL
AS SCHEDULED
METAL STUD
BLOCKING
WALL HUNG
FIXTURE
1/4" X 2" SHEET
METAL SCREWS,
6" MAX FROM
ENDS AND
24" OC MAX
TYPICAL BLOCKING DETAIL
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 2:
A
M
A-001
ARCHITECTURAL SYMBOLS,
ABBREVIATIONS, NOTES, PARTITION
TYPES AND DETAILS
1 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
ABBREVIATIONS
ARCHITECTURAL SYMBOL LEGEND
STANDARD MOUNTING HEIGHTS
1. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNER AS TO THE LIMITATIONS OF THE
WORK AREA IN AN OCCUPIED AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY
AGREEMENT BETWEEN THE COR AND CONTRACTOR BEFORE THE START OF THE WORK.
2. DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT DRAWINGS FOR SPECIFIC
PRODUCTS. DETAILS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE ACTUALLY
INCORPORATED INTO THE WORK, AND PRODUCTS BY OTHER MANUFACTURERS ARE ALSO
ACCEPTABLE. THEREFORE, ACTUAL INSTALLATION DETAILS AND DIMENSIONS MAY DIFFER FROM THOSE SHOWN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO
BE INCORPORATED IN THE WORK (INCLUDING THICKNESS FOR RECESSED OR SEMI-RECESSED
PRODUCTS) AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER
MATERIALS OR PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.
3. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO
WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS AND
SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY
SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND
UNIFIED WHOLE.
4. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE COR PRIOR TO
BIDDING. WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE
ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE CONTRACTOR SHALL
PROVIDE THE BETTER QUALITY OR GREATER QUANTITY OF WORK.
5. USE OF THE WORD "VERIFY" POINTS OUT A SITUATION WHICH MUST BE CONFIRMED PRIOR TO PROCEEDING WITH THE WORK, FABRICATION OF EQUIPMENT, OR ORDERING MATERIAL. NOTIFY THE
COR OF ANY DISCREPANCY DISCOVERED.
6. THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY SHOULD DISCREPANCIES BE FOUND IN THE
DRAWINGS AND SPECIFICATIONS.
7. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS AND DIMENSIONS AS THEY RELATE TO THIS PROJECT. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED
AND ACTUAL FIELD CONDITIONS NOTIFY THE COR PRIOR TO PROCEEDING WITH THE WORK.
8. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR REFERENCE ONLY AND
ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL OR DESIGNATED CONDITIONS. WRITTEN
DIMENSIONS SHALL GOVERN.
9. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
10. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND SYSTEMS TO MEET ALL APPLICABLE
FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS,
ETC. THE CONTRACTOR SHALL FURNISH ALL NECESSARY PERMITS.
11. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF THE
DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS (DRAWINGS,
SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE BUILDING, THE MAJOR
ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL, MECHANICAL, ELECTRICAL, AND DATA SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL
ALL THE NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE
DOCUMENTS, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THEIR WORK. ALL WORK SHALL BE COMPLETE IN EVERY DETAIL
AND THE CONTRACTORS SHALL PROVIDE A ONE YEAR WARRANTY FOR THEIR WORK UNLESS A
LONGER WARRANTY IS INDICATED IN THE SPECIFICATIONS.
12. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY
REGULATIONS AND HAZARDOUS WASTE LAWS, ETC.
13. PROVIDE WALL BLOCKING REINFORCEMENT FOR ALL WALL MOUNTED FIXTURES, EQUIPMENT AND
FURNITURE.
FF:VCT
FF:VCT
FF:CERAMI
FF:VCT
FF:CARPET
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
F
N268
N202
N204
N204
N265A
N267
N276
N222
N224
N226
N228
N230
N270
N229
N229A
N227
N227A
N225A
N232
N282C
N282B
N282A
N267A
N265
N
BALCONY
CORRIDOR
CORRIDOR
CORRIDOR
SIG
PROCESSING
VENDING
VEND
PACT
OFFICE
TOILET
EXAM
SOIL
UTILITY
STORAGE/MED
CLEAN
UTILITY
SCI CO-ORDR
OFFICE
MAIL RM
NFS
OFFICE
EXAM
TOILET
OFFICE
EXAM
LAB
TOILET
NFS
OFFICE
OFFICE
OFFICE
OFFICE
PACT
OFFICE
SU
GERI-PACT
LIMIT OF WORK
3' -4
9'
-1
1/ 2"
3' -2
/2
1'-10 3/4"
3'-3 1/4"
7 3/4"
3'-4"
EXISTING
CEILING
TRACK TO
REMAIN
5'-
0"
5'- 0"
5' -0
5'- 0"
7 7
9EXAM
ROOM
N281
EXAM
ROOM
N279
EXAM
ROOM
N277
WAITING
ROOM
N275
EXAM
ROOM
N275A
TOILET
N273A
WOMEN'S
CLINIC
N273
EXAM
ROOM
N269
OFFICE
N269A
TOILET
V269B
OFFICE
N275B
OFFICE
N269C
TOILET
N279A
NEW WALL
EXISTING TO REMAIN
DEMOLISHED WALL
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 2:
A
M
AD101
SECOND FLOOR DEMOLITION / ICRA
PLAN
2 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
0 2 4 8
NORTH
PLAN
Scale: 1/4" = 1'-0"1 SECOND FLOOR DEMOLITION PLAN / ICRA PLAN
1 REMOVE PLUMBING FIXTURES, ASSOCIATED
PIPING, AND OTHER RELATED ITEMS AS
NECESSARY. SEE PLUMBING DRAWINGS FOR
ADDITIONAL NOTES AND INSTRUCTIONS.
2 SEE DOOR SCHEDULE AND SPECIFICATION
087100 FOR DOOR, FRAME AND HARDWARE
REMOVAL AND RELOCATIONS.
3 CONSTRUCTION ANTEROOM WITH RATED DOOR.
4 PROVIDE TEMPORARY 1-HOUR RATED
SLAB-TOSLAB BARRIOR CONSISTING OF 3-5/8"
METAL STUD FRAMING WITH 5/8" TYPE X GYPSUM
WALL BOARD ON BOTH SIDES WITH 45 MINS.
RATED DOOR. BARRIERS SHALL BE INSPECTED
BY VA ICRA STAFF PROIR TO START OF
CONSTRUCTION IN SPACE. MAINTAIN NEGATIVE
PRESSURE V
5 PROVIDE STICKY MATS AT EACH CONSTRUCTION
ACCESS.
6 COORDINATE WITH COR ON SECURING THIS
EGRESS DOOR DURING CONSTRUCTION IN THIS
AREA.
7 EXISTING CURTAINS TO REMAIN.
8 REMOVE AND SALVAGE EXISTING CURTAINS.
RETURN TO OWNER.
9 REMOVE APPROXIMATELY 4'-6" OF HANDRAILS
AND BUMPER RAILS TO ACCOMMODATE NEW
DOOR OPENING. ADD RETURN END CAPS ON
BOTH SIDES.
WALL LEGEND
1. THE INFORMATION CONTAINED IN THESE
DEMOLITION DOCUMENTS DEFINES GENERAL SCOPE
ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF
THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION
REQUIRED FOR THE COMPLETION OF THE PROJECT.
2. THE CONTRACTOR SHALL, BEFORE THE START OF
WORK IDENTIFY ANY REQUIRED DEMOLITION
BEYOND THE IDENTIFIED PROJECT SCOPE WHETHER
ABOVE, BELOW, INSIDE EXISTING WALLS BEING
DEMOLISHED AND PATCHING, OR OUTSIDE PROJECT
AREA. THE CONTRACTOR SHALL PROVIDE
DEMOLITION OF THESE AREAS AS A PART OF THE
SCOPE OF THE PROJECT. NOTIFY AND COORDINATE
THIS WORK WITH THE COR.
3. REMOVE EXISTING CONSTRUCTION DESIGNATED
FOR DEMOLITION AND CLEAR AREA OF DEBRIS PRIOR
TO PROCEEDING WITH NEW CONSTRUCTION.
4. VERIFY ALL EXISTING CONDITIONS PRIOR TO
BEGINNING WORK. NOTIFY THE COR OF ANY
CONFLICTS AND DISCREPANCIES IN THE DRAWINGS
THAT ARE FOUND IN THE FIELD PRIOR TO
PROCEEDING WITH DEMOLITION.
5. DASH PATTERN REPRESENTS DEMOLITION WORK.
6. ALL ITEMS INCLUDING EQUIPMENT BEING REMOVED
SHALL REMAIN THE PROPERTY OF THE VA MEDICAL
CENTER UNTIL CONFIRMATION HAS BEEN MADE BY
THE VA COR AS TO WHETHER THE VA WILL RETAIN
SUCH ITEMS. ALL ITEMS NOT BEING RETAINED BY
THE COR OR DESIGNATED ON THE DRAWINGS TO BE
RELOCATED OR REINSTALLED SHALL BE REMOVED
FROM THE SITE.
7. REFER TO MECHANICAL, ELECTRICAL,
COMMUNICATION AND PLUMBING DOCUMENTS FOR
RESPECTIVE DEMOLITION AND NEW WORK
INFORMATION.
8. COORDINATE WORKING HOURS ALLOWED FOR
DEMOLITION WITH COR INSTRUCTED IN GENERAL
REQUIREMENTS.
9. DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS
NOT WITHIN THE SCOPE OF WORK.
10. PROJECT AREA ADJACENT TO THE DEMOTION AND
NEW CONSTRUCTION WORK TO PREVENT DAMAGES,
(IF DAMAGED REPAIR, RE-PATCH, SAND SMOOTH AND
REFINISH TO MATCH EXISTING.) REPAIR OR REPLACE
ITEMS DAMAGED DURING CONSTRUCTION ACTIVITIES
AT NO ADDITIONAL COST.
11. EXISTING CEILING SYSTEM INSIDE AREA OF WORK
ARE TO BE REMOVED UNLESS NOTED OTHERWISE
12. KEY NOTES AND DRAWINGS ARE INTENDED TO
GRAPHICALLY REPRESENT GENERAL WORK AND DO
NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE
SPECIFICATIONS FOR DETAILED REQUIREMENTS.
13. EXTENSIONS OF EXISTING WALL INFILL AND PATCHED
WALL OPENING SHALL MATCH THE INTEGRITY OF
ADJACENT CONSTRUCTION UNLESS INDICATED
OTHERWISE.
14. NOTIFY COR OF ANY AREA REQUIRING DEMOLITION
FOR INSTALLATION OF MECHANICAL, PLUMBING,
STRUCTURAL, ELECTRICAL, OR DATA ITEMS
(INCLUDING ROOF PENETRATIONS) NOT SHOWN IN
THESE DRAWINGS. AFTER SUCH DEMOLITION AND
INSTALLATION, PATCH OR REPLACE MATERIALS AND
FINISHES TO MATCH EXISTING.
15. ALL DEMOLITION WORK SHALL BE PERFORMED WITH
"DUE CARE AND DILIGENCE" IN ORDER TO PREVENT
ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE
OR CONCEALED UTILITIES INTENDED TO REMAIN IN
SERVICE. DISCOVERY OF UTILITIES OF CONDITIONS
LOCATED DIFFERENTLY FROM THAT INDICATED OF
THAT ARE NOT IDENTIFIED SHALL BE REPORTED TO
THE COR.
16. LEVEL CONCRETE FLOOR SLAB PRIOR TO
INSTALLING FINISH FLOOR MATERIAL. SEE
SPECIFICATIONS FOR CONCRETE SLAB INFILL WORK
REQUIREMENTS.
17. REMOVE OR REWORK CONDUITS HIDDEN INSIDE
DEMOLISHED WALLS.
# KEY NOTES:
N
SCOPE OUTLINE
SECOND FLOOR KEY PLAN
SCALE: NO SCALE
18. SEE SPECICIATION SECTION 013526 FOR ICRA AND
ILSM FORMS.
FF:VCT
FF:VCT
FF:CERAMIC T
FF:VCT
FF:CARPET
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:V
N268
N202
N204
N204
N265A
N267
N276
N222
N224
N226
N228
N230
N270
N229
N229A
N227
N227A
N225A
N232
N282C
N282B
N282A
N267A
N265
N23
BALCONY
CORRIDOR
CORRIDOR
CORRIDOR
SIG
LAB
PROCESSING
VENDING
VEND
PACT
OFFICE
TOILET
EXAM
SOIL
UTILITY
STORAGE/MED
CLEAN
UTILITY
SCI CO-ORDR
OFFICE
MAIL RM
NFS
OFFICE
EXAM
TOILET
OFFICE
EXAM
LAB
TOILET
NFS
OFFICE
OFFICE
OFFICE
OFFICE
PACT
OFFICE
SUP
GERI-PACT
LIMIT OF WORK
DASHED LINES
PREPRESENT
DEMOLITION OF
EXISTING CEILING
AND LIGHT FIXTURES
EXISTING CEILING AND
LIGHT FIXTURES TO
REMAIN
EXAM
ROOM
N281
EXAM
ROOM
N279
EXAM
ROOM
N277
WAITING
ROOM
N275
EXAM
ROOM
N275A
TOILET
N273A
WOMEN'S
CLINIC
N273
EXAM
ROOM
N269
OFFICE
N269A
TOILET
V269B
OFFICE
N275B
OFFICE
N269C
TOILET
N279A
NEW WALL
EXISTING TO REMAIN
DEMOLISHED WALL
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 3:
A
M
AD111
SECOND FLOOR REFLECTED CEILING
DEMOLITION PLAN
3 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
N
SCOPE OUTLINE
SECOND FLOOR KEY PLAN
SCALE: NO SCALE
Scale: 1/4" = 1'-0"1 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN 0 2 4 8
NORTH
PLAN
WALL LEGEND
1. THE INFORMATION CONTAINED IN THESE
DEMOLITION DOCUMENTS DEFINES GENERAL SCOPE
ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF
THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION
REQUIRED FOR THE COMPLETION OF THE PROJECT.
2. THE CONTRACTOR SHALL, BEFORE THE START OF
WORK IDENTIFY ANY REQUIRED DEMOLITION
BEYOND THE IDENTIFIED PROJECT SCOPE WHETHER
ABOVE, BELOW, INSIDE EXISTING WALLS BEING
DEMOLISHED AND PATCHING, OR OUTSIDE PROJECT
AREA. THE CONTRACTOR SHALL PROVIDE
DEMOLITION OF THESE AREAS AS A PART OF THE
SCOPE OF THE PROJECT. NOTIFY AND COORDINATE
THIS WORK WITH THE COR.
3. REMOVE EXISTING CONSTRUCTION DESIGNATED
FOR DEMOLITION AND CLEAR AREA OF DEBRIS PRIOR
TO PROCEEDING WITH NEW CONSTRUCTION.
4. VERIFY ALL EXISTING CONDITIONS PRIOR TO
BEGINNING WORK. NOTIFY THE COR OF ANY
CONFLICTS AND DISCREPANCIES IN THE DRAWINGS
THAT ARE FOUND IN THE FIELD PRIOR TO
PROCEEDING WITH DEMOLITION.
5. DASH PATTERN REPRESENTS DEMOLITION WORK.
6. ALL ITEMS INCLUDING EQUIPMENT BEING REMOVED
SHALL REMAIN THE PROPERTY OF THE VA MEDICAL
CENTER UNTIL CONFIRMATION HAS BEEN MADE BY
THE VA COR AS TO WHETHER THE VA WILL RETAIN
SUCH ITEMS. ALL ITEMS NOT BEING RETAINED BY
THE COR OR DESIGNATED ON THE DRAWINGS TO BE
RELOCATED OR REINSTALLED SHALL BE REMOVED
FROM THE SITE.
7. REFER TO MECHANICAL, ELECTRICAL,
COMMUNICATION AND PLUMBING DOCUMENTS FOR
RESPECTIVE DEMOLITION AND NEW WORK
INFORMATION.
8. COORDINATE WORKING HOURS ALLOWED FOR
DEMOLITION WITH COR INSTRUCTED IN GENERAL
REQUIREMENTS.
9. DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS
NOT WITHIN THE SCOPE OF WORK.
10. PROJECT AREA ADJACENT TO THE DEMOTION AND
NEW CONSTRUCTION WORK TO PREVENT DAMAGES,
(IF DAMAGED REPAIR, RE-PATCH, SAND SMOOTH AND
REFINISH TO MATCH EXISTING.) REPAIR OR REPLACE
ITEMS DAMAGED DURING CONSTRUCTION ACTIVITIES
AT NO ADDITIONAL COST.
11. EXISTING CEILING SYSTEM INSIDE AREA OF WORK
ARE TO BE REMOVED UNLESS NOTED OTHERWISE
12. KEY NOTES AND DRAWINGS ARE INTENDED TO
GRAPHICALLY REPRESENT GENERAL WORK AND DO
NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE
SPECIFICATIONS FOR DETAILED REQUIREMENTS.
13. EXTENSIONS OF EXISTING WALL INFILL AND PATCHED
WALL OPENING SHALL MATCH THE INTEGRITY OF
ADJACENT CONSTRUCTION UNLESS INDICATED
OTHERWISE.
14. NOTIFY COR OF ANY AREA REQUIRING DEMOLITION
FOR INSTALLATION OF MECHANICAL, PLUMBING,
STRUCTURAL, ELECTRICAL, OR DATA ITEMS
(INCLUDING ROOF PENETRATIONS) NOT SHOWN IN
THESE DRAWINGS. AFTER SUCH DEMOLITION AND
INSTALLATION, PATCH OR REPLACE MATERIALS AND
FINISHES TO MATCH EXISTING.
15. ALL DEMOLITION WORK SHALL BE PERFORMED WITH
"DUE CARE AND DILIGENCE" IN ORDER TO PREVENT
ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE
OR CONCEALED UTILITIES INTENDED TO REMAIN IN
SERVICE. DISCOVERY OF UTILITIES OF CONDITIONS
LOCATED DIFFERENTLY FROM THAT INDICATED OF
THAT ARE NOT IDENTIFIED SHALL BE REPORTED TO
THE COR.
16. LEVEL CONCRETE FLOOR SLAB PRIOR TO
INSTALLING FINISH FLOOR MATERIAL. SEE
SPECIFICATIONS FOR CONCRETE SLAB INFILL WORK
REQUIREMENTS.
17. REMOVE OR REWORK CONDUITS HIDDEN INSIDE
DEMOLISHED WALLS .
18. EXISTING SPRINKLER SYSTEM TO REMAIN (UNO).
FF:VCT
FF:VCT
FF:C
FF:V
FF:CARPET
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:V
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
N268
N202
N204
N204
N265A
N267
N276
N222
N224
N226
N228
N230
N270
N22
N227
N227A
N225A
N232
N282C
N282B
N282A
N267A
N265
BALCONY
CORRIDOR
CORRIDOR
CORR
SIG
PROCESSING
VENDING
VEND
PACT
OFFICE
TOILET
EXAM
SOIL
UTILITY
STORAGE/MED
CLEAN
UTILITY
SCI CO-ORDR
OFFICE
MAIL RM
NFS
OFFICE
EXAM
OFFICE
EXAM
LAB
TOILET
NFS
OFFICE
OFFICE
OFFICE
OFFICE
PACT
OFFICE
GERI-PAC
AI201
AI201
AI201 9
EXAM
ROOM
N269A
WAITING
ROOM
N275
N275A
CLERK
LACTATION
LOUNGE
N273
WOMEN'S
CLINIC
N271
EXAM
ROOM
N269B
TOILET
N269C
CLINIC
SUPPORT
OFFICE
N269D
LPN
N269
NURSE
EXAM
N271A
LPN
N277A
PACT
N277
TOILET
N277B
NURSE
EXAM
N279
EXAM
ROOM
N281
OFFICE/
EXAM
ROOM
N283
N275A
N275
N271
N269D N269A
N269B-1
N277B
N269C-1
N269C-2
N269B-2
N283
N281 N279
N277A
N271A
N273
N269
N277
3.1
3.1
3.0
3.0
3.1
3.1
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
AI401
AI401
AI401
LIMIT OF WORK
VIF
9'-6 3/4" 4'-7" 4'-7 3/4" 8'-5" 4'-1"
13'-8 3/4" 13'-9 1/4"
8' -5
9'
-6
/2
ALIGN
ALIGN
4'-0 1/4"
3'- 6 3
/4"
ALIG
N 13'-4 1/2"
7'-3 1/4"2
ALIGN
9'-10 1/2"
3'-6"
5'-10"
2' -0
5'
-5
CR
CR
C
LR
6' -0
AI201
AI401
UPPER
WALL
MOUNTED
TV
KIOSK
AI201
AI201
11 12
3.0
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
AI201
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2 PT-2
PT-2
PT-2
PT-2
LVT-2
LVT-2
EXISTING
TO REMAIN
SV-1
SV-1
LVT-1
LVT-2
LVT-2
LVT-1
LVT-2
LVT-2
LVT-1
LVT-1
LVT-1
LVT-2
LVT-2
LVT-1
LVT-1
LVT-2 LVT-2
LVT-2
LVT-2
SV-1 LVT-1
LVT-1
NEW WALL
EXISTING TO REMAIN
DEMOLISHED WALL
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
# KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 3:
A
M
AI101
RENOVATION PLAN
4 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
0 2 4 8
NORTH
PLAN
Scale: 1/4" = 1'-0"1 SECOND FLOOR RENOVATION PLAN
N
SCOPE OUTLINE
SECOND FLOOR KEY PLAN
SCALE: NO SCALE
1. SEE SHEET A-001 FOR PARTITION TYPES.
2. DASHED FURNITURE FIXTURES AND EQUIPMENT
ARE PROVIDED BY VA.
3. LEVEL CONCRETE FLOOR SLAB PRIOR TO
INSTALLING FINISH FLOOR MATERIAL.
4. ALL DIMENSIONS ARE TO FACE OF STUD, CMU
AND/OR MASONRY UNLESS NOTED OTHERWISE.
5. USE GYPSUM BOARD TYPE "MR" AT ALL WET
LOCATIONS. STOP BOARD AT 1/2" ABOVE FLOOR
LINE.
6. SEE SHEET GI101 FOR LIFE SAFETY PLAN AND
LOCATIONS OF RATED PARTITIONS AND
SEPARATION INFORMATION.
7. DISSIMILAR FLOOR MATERIALS SHALL MEET
UNDER CENTER OF DOOR LEAF.
8. EACH CONTRACTOR SHALL COORDINATE THEIR
WORK WITH ALL OTHER TRADES.
9. HINGE SIDE OF DOOR JAMBS TO BE LOCATED 4"
FROM NEAREST WALL INTERSECTION UNLESS
NOTED OTHERWISE.
10. EXISTING CONDITION INFORMATION SHOWN
WITHIN THE PROJECT AREA IS BASED ON FIELD
OBSERVATION AND EXISTING DRAWING
DOCUMENTATION. ALL EXISTING CONDITION
INFORMATION SHOWN OUTSIDE THE PROJECT
AREA IS PROVIDED FOR REFERENCE ONLY AND
HAS NOT BEEN FIELD VERIFIED. CONTRACTOR IS
RESPONSIBLE FOR VERIFYING ALL EXISTING
CONDITIONS PRIOR TO BEGINNING ANY NEW
WORK AND SHALL BRING ANY DISCREPANCIES
TO THE ATTENTION OF THE COR PRIOR TO
DEMOLITION AND CONSTRUCTION.
11. ALL AP DEVICES TO REMAIN.
12. BABY CHANGING STATION PROVIDED BY
CONTRACTOR.
13. BOTTOM OF WALL MOUNTED TV IN WAITING
ROOM N275 SHALL BE AT 6'-8" AFF.
1 NEW PLUMBING FIXTURE. SEE PLUMBING
DRAWINGS FOR FURTHER INSTRUCTION AND
NOTES.
2 INFILL WALLS TO MATCH ADJACENT WALL
CONSTRUCTION AND FINISH, TYPICAL
3 NEW GYPSUM WALL BOARD.
4 RECESSED STAINLESS STEEL BABY CHANGING
STATION (PROVIDED AND INSTALL BY
CONTRACTOR)
5 ADD NEW HANDRAIL AND BUMPER RAIL TO
MATCH EXISTING AT WALL INFILL
WALL LEGEND
FF:VCT
FF:VCT
FF:CERAMIC
FF:VCT
FF:CARPET
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CERAMIC TILE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:CONCRETE
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
FF:VCT
F
N268
N202
N204
N204
N265A
N267
N276
N222
N224
N226
N228
N230
N270
N229
N229A
N227
N227A
N225A
N232
N282C
N282B
N282A
N267A
N265
N
BALCONY
CORRIDOR
CORRIDOR
CORRIDOR
SIG
VENDING
VEND
PACT
OFFICE
TOILET
EXAM
SOIL
UTILITY
STORAGE/MED
CLEAN
UTILITY
SCI CO-ORDR
OFFICE
MAIL RM
NFS
OFFICE
EXAM
TOILET
OFFICE
EXAM
LAB
TOILET
NFS
OFFICE
OFFICE
OFFICE
PACT
OFFICE
SU
GERI-PACT
VS
OS
OS
OS
OS
OS
VS
EXAM
ROOM
N269A
WAITING
ROOM
N275
CLERK
N275A
LACTATION
LOUNGE
N273
WOMEN'S
CLINIC
N271
EXAM
ROOM
N269B
TOILET
N269C
CLINIC
SUPPORT
OFFICE
N269D
LPN
N269
NURSE
EXAM
N271A
LPN
N277A
PACT
N277
TOILET
N277B
NURSE
EXAM
N279
EXAM
ROOM
N281
OFFICE/
EXAM
ROOM
N283
LIMIT OF WORK
6"
VS OS
DENOTES GWB
SOFFIT/CEILING
RETURN GRILL
SUPPLY
DIFFUSER
CURTAIN TRACK
VANCY SENSOR
OCCUPANCY
SENSOR
2'X2' LED FIXTURE
2'X4' LED
FIXTURE
EXIT SIGN
(SHADED AREA
INDICATES
DIRECTION OF
EGRESS)
FIRE SPRINKLER
SCONCE
DENOTES
2'X2' ACT
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 3:
A
M
AI111
REFLECTED CEILING PLAN
5 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
N
SCOPE OUTLINE
SECOND FLOOR KEY PLAN
SCALE: NO SCALE
Scale: 1/4" = 1'-0"1 SECOND FLOOR REFLECTED CEILING PLAN 0 2 4 8
NORTH
PLAN
RCP LEGEND:
1. ALL CEILING HEIGHT TO MATCH EXISTING (UNO).
2'-1 3/4"ANGLED
3' -1
1" 8"
3/
4"
2' -9
1' -3
/2
1'
-7
/2
REFER TO
PLUMBING FOR
DETAILS
REFER TO
ELECTRICAL
FOR DETAILS
24" PREFERRED
18" MIN,
" M
IN
" M
IN
BOTH LATCH AND CLOSER
12" IF DOOR HAS
FRONT APPROACHES - SWINGING DOORS
X
Y
LA
TC
H
AN
D
CL
OS
ER
MI
N.
" I
F
DO
OR
H
AS
HINGE SIDE APPROACHES - SWINGING DOORS
54" MIN.
NOTE: X = 36 " MIN IF Y = 60",
X = 42" MIN. IF Y = 54"
24" MIN.
" M
IN
. IF
D
OO
R
HA
S
CL
OS
ER
" M
IN
MI
N.
" I F
DO
OR
H
AS
C
LO
SE
R
LATCH SIDE APPROACHES - SWINGING DOORS
24" MIN.
1/2"
2"
VARIES
STEEL FRAME
SEALANT
EACH SIDE
BOX HEADER
1/ 2"
2"
VA
R
IE
S
DOUBLE STUD SEALANT EACH
SIDE
STEEL FRAME
JAMB ANCHOR
F1D1
2"
SE
E
SC
H
ED
U
LE
2" SEE SCHEDULE 2"
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
4" 2'
-1
1' -0
3'
-1 1"
8"
R.O.
3'-8" 5"
R.O.
6'-4 1/2" ANGLED
R .O
4'
-1 1" 3'
-1 1"
2' -5
2'-8 1/2"3'-8"
RESTROOM PHOTO OF FINISHES, EXAMPLE
3'-0"
1' -6
2'-0"
VWC-1
CT-1
SS-1
SV-1* SV-1*
SS-1
CT-1
VWC-1
2" 5'
-0
6"
5' -8
TA004
TA009
TA003
TA002
TA007
TA001
VWC-1
CT-1
SS-1
SV-1* SV-1*
VWC-1
CT-1
5' -0
2"
TA001
TA007
TA002
6" 5'
-0
2"
5' -8
VWC-1
SV-1*
VWC-1
CT-1
TA003
VWC-1
CT-1
SS-1
SV-1* SV-1*
SS-1
CT-1
VWC-1
6" 5'
-0
2"
5' -8
TA004
TA009
TA006
VWC-1
CT-1
SS-1
SV-1* SV-1*
CT-1
5' -0
2"
VWC-1
SV-1*
CT-1
6" 5'
-0
2"
SV-1*
CT-1
CT-1
VWC-1
5' -8
TA003
VWC-1
CT-1
SS-1
SV-1* SV-1*
SS-1
CT-1
VWC-1
6" 5'
-0
2"
5' -8
TA006
TA004
TA009
VWC-1
SS-1
SV-1*
SV-1*
SS-1
CT-1
VWC-1
VWC-1
EXISTING
WINDOW TO
REMAIN
2" 5'
-0
6" 5'
-8
2'-0"
TA001
TA009
TA003
TA004
TA007
TA002
2' -7
FINISH LEGEND
CODE MANUFACTURER SERIES / PATTERN COLOR NUMBER / NAME
PT-1 GLIDDEN PROFESSIONAL SATIN - WALLS
USE PT-1 FOR ALL DOOR FRAMES
DOOR FRAMES *SEMI-GLOSS
30 / YY 50 / 082 / SAND WHITE
PT-2 PITTSBURGH PAINTS 507-4 / GEORGIAN SILVER
VWC-1 VYKON WALLCOVERING SAFARI Y47173SF / ZEBRA
VWC-2 NATIONAL WALLCOVERING LEVEL PATTERN TBD
LVT-1 SHAW JEOGORI 0215V / LINEN
LVT-2 SHAW TERRAIN 00766 / ECHO
SV-1 MANNINGTON PARADIGM COLLECTION PAR206 / STREAMLINE
B1 JOHNSONITE TRADITIONAL 4" VINYL 80 / FAWN
B2 JOHNSONITE MILLWORKS INFLECTION 80 / FAWN
CT-1 FLORIDA TILE CONTINENT 12X24 29936 / COASTAL SAND
GROUT: ACCUCOLOR, BIRCH
SS-1 IN-PRO SOLID SURFACE P9054 / GRAVEL
CG-1 CSACROVYN 2" CORNER GUARD OYSTER GRAY
2' -1
0"
1' -5
"33 "-3
6"
TA001
GRAB BAR
M
AX
1' -1
0"
TA002
TOILET
PAPER
DISPENSER
2' -1
0"
TA003
RECESSED
BABY
CHANGING
STATION
2' -1
0"
TA004
SOAP
DISPENSER
WALL MOUNTED
M
AX
3' -4
TA006
MIRROR
2' -8
TA007
SANITARY
NAPKIN
DISPOSAL
3' -4
TA008 - RECESSED
TA009 - WALL MOUNT
PAPER TOWEL
DISPENSER
SINK
WALL
MOUNTED
TOILET
WALL
MOUNTED
TOILET ACCESSORIES LEGEND
WALL
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
ERED ARCHITECT
N O
R T H CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
3/
/2
:0 3:
A
M
AI201
INTERIOR ELEVATIONS, DOOR
SCHEDULE, ELEVATION AND DETAILS
6 7KC GTS
RENOVATE WOMEN'S
HEALTH CLINIC
JAMES H QUILLEN VAMC
LAMONT & VETERANS WAY
MOUNTAIN HOME, TN MARCH 28, 2019
CONSTRUCTION DOCUMENTS
621-17-11018-014
Scale: 1/2" = 1'-0"6 INTERIOR ELEVATION
Scale: 1/2" = 1'-0"
PARTIAL ELEVATION -
COMPASS UNIT NIC,
TYPICAL5Scale: 1/2" = 1'-0"
MODULAR DESK
ELEVATION, NIC TYPICAL9
DOOR SCHEDULE
DOOR DOOR FRAME
HDWR SET NO. REMARKSNO. WIDTH HEIGHT THICK MAT'L FINISH ELEV MAT'L FINISH
SECOND FLOOR
N269 3' - 0" 7' - 0" 1 3/4" WD/ETR* CLEAR ETR HM/ETR* PT-1 3.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N269A 3' - 6" 7' - 0" 1 3/4" WD-ETR CLEAR ETR HM/ETR PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N269B-1 3' - 6" 7' - 0" 1 3/4" WD-ETR CLEAR ETR HM*/ETR PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N269B-2 3' - 0" 7' - 0" 1 3/4" ALUM ETR ETR ALUM PT-1 ETR NO WORK
N269C-1 3' - 0" 7' - 0" 1 3/4" ETR CLEAR ETR ETR PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N269C-2 3' - 0" 7' - 0" 1 3/4" ETR CLEAR ETR HM/ETR PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N269D 3' - 6" 7' - 0" 1 3/4" ETR ETR ETR HM/ETR PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N271 3' - 6" 7' - 0" 1 3/4" ETR ETR ETR HM/ETR PT-1 4.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME. NEW HARDWARE AND CARD READER
N271A 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM* PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N273 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM PT-1 2.0 45 MIN. RATING, RELOCATE EXISTING DOOR AND FRAME FROM EXISTING EXAM ROOM N277 N275 3' - 6" 7' - 0" 1 3/4" ETR ETR ETR HM PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N275A 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM*/ETR PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N277 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM* PT-1 4.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME. NEW HARDWARE AND CARD READER
N277A 3' - 0" 7' - 0" 1 3/4" WD CLEAR D1/F1 HM PT-1 3.0 INSTALL NEW DOOR, FRAMES AND HARDWARE. WOOD DOOR TO MATCH EXISTING.
N277B 3' - 0" 7' - 0" 1 3/4" ETR ETR ETR ETR PT-1 ETR, 5.0 REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N279 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM* PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N281 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM* PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
N283 3' - 0" 7' - 0" 1 3/4" WD CLEAR ETR HM* PT-1 1.0 * RELOCATED EXISTING DOOR AND FRAME. REFURBISH AND REFINISH EXISTING DOOR, PAINT HM FRAME.
AL= ALUMINUM
ALCW= ALUMINUM CLAD WOOD
ETR= EXISTING TO REMAIN
EXIST= EXISTING
FRP= FIBER REINFORCED PLASTIC
HM= HOLLOW METAL
IHM= INSULATED HOLLOW METAL
OHD= OVERHEAD DOOR
PF= PREFINISHED
PT= PAINT
SCW= SOLID CORE WOOD
STN= STAIN
WD= WOOD
1. REFURBISH, RELOCATE AND REUSE EXISTING
DOORS. NEW DOORS PROVIDED FOR SHORTAGE
ONLY.
2. PROVIDE NEW HARDWARE (UNO).
3. REFURBISH AND REFINISH ALL DOORS AND
FRAMES.
4. INSULATE AROUND EXPOSED LAVATORY PIPING,
TYPICAL. SEE PLUMBING DRAWINGS FOR MORE
DETAILS AND INFORMATION.
5. REFER TO MECHANICAL, ELECTRICAL,
COMMUNICATION AND PLUMBING DOCUMENTS
FOR ADDITIONAL NEW WORK INFORMATION.
Scale: 1/4" = 1'-0"15 DOOR CLEARANCES
Scale: 3" = 1'-0"16 DOOR INTERIOR HEAD DETAIL
Scale: 3" = 1'-0"17 DOOR INTERIOR JAMB DETAIL
Scale: 1/2" = 1'-0"
DOOR ELEVATION
ROOM FINISH SCHEDULE
ROOM NO. NAME FLOOR BASE
WALLS CEILING
CEILING HEIGHT REMARKS
EAST NORTH SOUTH WEST
FINISHMAT'L FINISH MAT'L FINISH MAT'L FINISH MAT'L FINISH
SECOND FLOOR
N269 LPN LVT-1 B1 GWB PT-1 GWB PT-2 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N269A EXAM ROOM LVT-1 B1 GWB PT-2 GWB PT-1 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N269B EXAM ROOM LVT-1 B1 GWB PT-2 GWB PT-1 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N269C TOILET SV-1 SV-1* GWB VWC-1/SS-1 GWB VWC-1/CT-1 GWB VWC-1/SS-1 GWB VWC-1/SS-1 ACT MATCH EXISTING *INTEGRAL BASE N269D CLINIC SUPPORT OFFICE LVT-1 B1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-2 ACT MATCH EXISTING N271 WOMEN'S CLINIC LVT-2 B2 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N271A NURSE EXAM LVT-1 B1 GWB PT-2 GWB PT-1 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N273 LACTATION LOUNGE LVT-2 B2 GWB PT-1 GWB PT-1 GWB PT-2 GWB PT-1 ACT MATCH EXISTING N275 WAITING ROOM LVT-2 B2 GWB VWC-2/PT-1 GWB VWC-2/PT-1 GWB VWC-2/PT-1 GWB VWC-2/PT-1 ACT MATCH EXISTING FLOOR-HERRINGB
ONE PATTERN
N275A CLERK LVT-1 B1 GWB PT-1 GWB PT-1 GWB PT-2 GWB PT-1 ACT MATCH EXISTING
N277 PACT LVT-2 B2 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N277A LPN LVT-1 B1 GWB PT-1 GWB PT-2 GWB PT-1 GWB PT-1 ACT MATCH EXISTING
N277B TOILET SV-1 SV-1* GWB VWC-1/SS-1 GWB VWC-1/SS-1 GWB VWC-1/SS-1 GWB VWC-1/CT-1 ACT MATCH EXISTING *INTEGRAL BASE
N279 NURSE EXAM LVT-1 B1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-2 ACT MATCH EXISTING
N281 EXAM ROOM LVT-1 B1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-2 ACT MATCH EXISTING
N283 OFFICE/ EXAM ROOM LVT-1 B1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-2 ACT MATCH EXISTING
ACT= ACOUSTICAL CEILING TILE
B= BASE (RUBBER OR VINYL)
CT= CERAMIC TILE (WALL AND BASE)
GWB= GYPSUM WALL BOARD
LVT= LUXURY VINYL TILE
PT= PAINT
SS= SOLID SURFACE
SV= SHEET VINYL
VWC= VINYL WALL COVERING
Scale: 1/2" = 1'-0"10 INTERIOR ELEVATION Scale: No Scale
2 RESTROOM PROTOTYPE, FOR REFERENCE ONLY
Scale: 1/2" = 1'-0"3 NORTH INTERIOR ELEVATION
Scale: 1/2" = 1'-0"4 EAST INTERIOR ELEVATION
Scale: 1/2" = 1'-0"7 SOUTH INTERIOR ELEVATION
Scale: 1/2" = 1'-0"8 WEST INTERIOR ELEVATION
SHEET NOTES:
Scale: 1/2" = 1'-0"11 NORTHWEST INTERIOR ELEVATION
Scale: 1/2" = 1'-0"12 NORTHEAST INTERIOR ELEVATION
Scale: 1/2" = 1'-0"13 SOUTHEAST INTERIOR ELEVATION
Scale: 1/2" = 1'-0"14 SOUTHWEST INTERIOR ELEVATION
Scale: 1/2" = 1'-0"
PARTIAL ELEVATION -
MONITOR UNIT, NIC TYPICAL1
TA001
TA007
TA002
FINISH LEGEND
DOOR LEGEND
72"
DC
CR
ES
ES
CR
3/4" PARTICLE
BOARD WITH 1/2"
SOLID SURFACE
WORK SURFACE W/
1/4" RADIUS
CONCEALED WALL
MOUNT SUPPORT
BRACKET - SPACE AT
4'-0" MAX. INSTALL
AND PROVIDE
BLOCKING PER
MANUFACTURER'S
RECOMMENDATIONS.
1" X 4" CONT.
WOOD
BLOCKING (TYP.)
3 5/8" METAL STUDS
@16" OC WITH 5/8"
GYPSUM BOARD
BOTH SIDES
4" 1'
-0
2' -6
2 1/2" METAL STUDS
@16" OC
3/4" PLYWOOD WITH
PLASTIC LAMINATE
RESILIENT BASE
2' -2
1'
-0
SOLID SURFACE
TRANSACTION TOP
W/ 1/4" RADIUS
10"
1'-9"
1/4" CLEAR
TEMPERED GLAZING
ALUMINUN SLIDING
PASS-THRU WINDOW
SE
E
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
3 5/8" METAL STUDS
@16" OC WITH 5/8"
GYPSUM BOARD ON
BOTH SIDES
1" 1"
3 1/4"
3/4" PARTICLE BOARD
WITH 1/2" SOLID
SURFACE AND 4"
BACKSPLASH
CONCEALED WALL
MOUNT SUPPORT
BRACKET - SPACE AT
4'-0" MAX. INSTALL
AND PROVIDE
BLOCKING PER
MANUFACTURER'S
RECOMMENDATIONS.
1" X 3" CONT. WOOD
BLOCKING (TYP.)
3 5/8" METAL
STUDS @16" OC
WITH 5/8" GYPSUM
BOARD ON BOTH
SIDES
3' -6
RESILIENT BASE
1'-9 1/2"
7/8" HAT
CHANNEL
16" OC,
VERTICAL
EXTERIOR WALL
EXISTING
WALLS TO
REMAIN
EXISTING
WALLS TO
REMAIN
CAULK
CONTROL
JOINT
7/8" HAT CHANNELS
16" OC VERTICAL
NEW WALL AS SCHEDULED
3-5/8" METAL STUD FRAMING
5/8" GYPSUM WALL BOARD, BOTH SIDES
EXISTING COLUMN
EXISTING TO
REMAIN
PATCH AND REPAIR GYPSUM
NEW WALL AS SCHEDULED
3-5/8" METAL STUD FRAMING
5/8" GYPSUM WALL
BOARD, BOTH SIDES
EXISTING WALL TO REMAIN
NEW WALL
EXISTING TO REMAIN
DEMOLISHED WALL
AI201
AI201
WAITING
ROOM
N275
CLERK
N275A
LACTATION
LOUNGE
N273
AI401
AI401
FOW7'-
1"
1'- 2 3
/4"
3'-8"
5'-0"
5'-10 3/4"
9'-6 1/2"
1' -9
AI401
_____2
135°
AI401
3"
3'- 3 3
/4"
3"
3/4" PARTICLE BOARD
WITH 1/2" SOLID
SURFACE WORK
SURFACE W/ 1/4"
RADIUS
CONCEALED WALL
MOUNT SUPPORT
BRACKET - SPACE AT
4'-0" MAX. INSTALL
AND PROVIDE
BLOCKING PER
MANUFACTURER'S
RECOMMENDATIONS.
1" X 4" CONT. WOOD
BLOCKING (TYP.)
3 5/8" METAL STUDS
@16" OC WITH 5/8"
GYPSUM BOARD
4" 2'
-6
2 1/2" METAL STUDS
@16" OC
3/4" PLYWOOD WITH
PLASTIC LAMINATE
RESILIENT BASE
2' -2
1'-9"
1/4" CLEAR TEMPERED
GLAZING
ALUMINUN SLIDING
PASS-THRU WINDOW
3 5/8" METAL STUDS
@16" OC WITH 5/8"
GYPSUM BOARD ON
BOTH SIDES
1'-2"
A
LAR
E GI H,NC
S
GO 52644P
E
N
CO
LU IT
E
NG
RG
UO
A.
P,P.
R E
G I
S T
E R
E D
A R C H I T E C T U R A L
C O
R P
O T
I O
N
N O R T H C A R O L I N A
A R
LA
R
E GI H, NC
N
11664
IK
G HC OY
RE
G I
ST
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .