About this file

36C24918B0361 Section 08 36 13 Sectional Doors.pdf

View the file

Other files

File Type Posted
36C24918C0185-000.docx DOCX document
36C24918B0361-0002000.docx DOCX document
36C24918B0361-0001000.docx DOCX document
36C24918B0361-022.pdf PDF
36C24918B0361-017.pdf PDF
36C24918B0361-003.pdf PDF
36C24918B0361-008.pdf PDF
36C24918B0361-015.pdf PDF
36C24918B0361-005.pdf PDF
36C24918B0361-011.pdf PDF
36C24918B0361-010.pdf PDF
36C24918B0361-014.pdf PDF
36C24918B0361-009.pdf PDF
36C24918B0361-021.pdf PDF
36C24918B0361-001.docx DOCX document
36C24918B0361-018.pdf PDF
36C24918B0361-026.pdf PDF
36C24918B0361-007.pdf PDF
36C24918B0361-023.pdf PDF
36C24918B0361-020.pdf PDF
36C24918B0361-006.pdf PDF
36C24918B0361-012.pdf PDF
36C24918B0361-004.pdf PDF
36C24918B0361-019.pdf PDF
36C24918B0361-025.pdf PDF
36C24918B0361-013.pdf PDF
36C24918B0361-016.pdf PDF
36C24918B0361-002.pdf PDF
36C24918B0361-000.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

05-01-15

08 36 13 - 1

SECTION 08 36 13

SECTIONAL DOORS

PART 1 - GENERAL

1.1 DESCRIPTION:

A. This section specifies manually operated sectional overhead steel doors.

1.2 RELATED WORK:

A. Lock Cylinders for Cylindrical Locks: Section 08 71 00, DOOR HARDWARE.

B. Field Painting of Factory Primed Doors: Section 09 91 00, PAINTING.

1.3 MANUFACTURER'S AND INSTALLER'S QUALIFICATIONS:

A. Manufacturer's with three (3) years’ experience in providing items of type specified. Submit manufacturer qualifications.

B. Installers who are trained and approved by manufacturer for installation of units required. Submit installer qualifications.

1.4 SUBMITTALS:

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Shop Drawings:

1. Details of construction, accessories and hardware, mechanical items, and safety devices.

C. Manufacturer's Literature and Data:

1. Brochures or catalog cuts.

2. Manufacturer's installation procedures and instructions.

3. Maintenance instructions, parts list.

D. Installer’s qualifications.

E. Manufacturer’s qualifications.

F. Certificates:

1. Attesting door, anchors and hardware will withstand the horizontal loads specified.

2. Attesting door complies with thermal performance, air infiltration, and water infiltration requirements.

G. Manufacturer warranty.

1.5 QUALITY ASSURANCE:

A. Source: Obtain sectional doors from single source from single manufacturer. Obtain operators and controls from sectional door manufacturer.

08 36 13 - 2

1.6 WARRANTY:

A. Construction Warranty: Comply with FAR clause 52.246-21 “Warranty of

Construction”.

B. Manufacturer Warranty: Manufacturer shall warranty their sectional doors for a minimum of two (2) years from the date of installation and final acceptance by the Government. Submit manufacturer warranty.

1.7 APPLICABLE PUBLICATIONS:

A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in the text by the basic designation only.

B. American Architectural Manufacturers Association (AAMA):

2603-13.................Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum

Extrusions and Panels

C. American Society of Civil Engineers (ASCE):

7-10....................Wind Load Provisions

D. ASTM International (ASTM):

A36/A36M-14.............Structural Steel

A227/A227M-06(R2011)....Steel Wire, Cold-Drawn for Mechanical Springs

A229/229M-12............Steel Wire, Oil-Tempered for Mechanical Springs

A653/A653M-12(R2013)....Steel Sheet, Zinc-Coated (Galvanized) or Zinc

Iron Alloy Coated (Galvanized) by the Hot Dip

Process

C1036-11(R2012).........Flat Glass

C1363-11................Test Method for Thermal Performance of Building

Materials and Envelope Assemblies by Means of a

Hot Box Apparatus

E84-14..................Surface Burning Characteristics of Building

Materials

E283-04(R2012)..........Determining the Rate of Air Leakage Through

Exterior Windows, Curtain Walls, and Doors

Under Specified Pressure Difference Across the

Specimen

E330/E330M-14...........Structural Performance of Exterior Windows, Curtain Walls, and Doors by the Uniform Static

Air Pressure Difference.

08 36 13 - 3

E331-00(R2009)..........Water Penetration of Exterior Windows, Curtain

Walls, and Doors by the Uniform Static Air

Pressure Difference.

E. American National Standards Institute and Door and Access Systems

Manufacturers Association (ANSI/DASMA):

102-11..................Sectional Overhead Type Doors.

F. National Electrical Manufacturer's Association (NEMA):

ICS 6-93(R2011).........Industrial Controls and Systems: Enclosures

MG 1-11(R2014)..........Motors and Generators

ST 20-14................Dry Type Transformers for General Applications

G. National Fire Protection Association (NFPA):

70-14...................National Electrical Code

H. National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06..............Metal Finishes Manual

I. Underwriters Laboratories, Inc. (UL):

325-06(R2013)...........Door, Drapery, Gate, Louver, and Window

Operators and Systems

PART 2 - PRODUCTS

2.1 MATERIALS:

A. Steel: ASTM A653/A653M for forming operations. ASTM A36/A36M for structural sections.

B. Hard Drawn Spring wire: ASTM A227/A227M.

C. Oil Tempered Spring wire: ASTM A229/A229M.

D. Weather-strips, Gaskets, and Thermal Breaks:

1. Neoprene, EPDM, PVC, silicone rubber, or other low conductance material.

2. Standard with door manufacturer.

2.2 DESIGN REQUIREMENTS:

A. Wind Load: Design to withstand uniform pressure (velocity pressure) of

960 Pa (20 lbs. per sq. ft.) acting inward and outward when tested in accordance with ASTM E330/E330M. Doors are to remain operable under design wind load.

B. Thermal Performance for Insulated Doors: Maximum U value of 0.14 for door when tested in accordance with ASTM C1363.

C. Air Infiltration for Exterior Doors: Maximum of 0.10 cfm at 24 Km

(15 miles per hour) wind speed per foot of crack between door sections and door perimeter opening when tested in accordance with ASTM E283.

08 36 13 - 4

D. Water Infiltration for Exterior Doors: No infiltration when tested in accordance with ASTM E331.

E. Comply with ANSI/DASMA 102. Provide metal doors with horizontal sections hinged together to operate in a system of tracks to completely close the door opening in the closed position and make the full width and height of the door opening available for use in the open position.

F. Operation-Cycle Requirements: Door components and actuators to operate for not less than 10,000 cycles.

2.3 FABRICATION:

A. Steel Door Sections:

1. Formed of hot-dipped galvanized steel.

2. Meeting rails: Interlocking joints with thermal breaks separating face sheets formed to provide weathertight closure and alignment for full width of door.

3. Height of Each Section: Not to exceed 610 mm (24 inches).

4. Provide board insulation with flame spread rating of not more than

25 and a smoke development factor of not more than 50 when tested in accordance with ASTM E84.

6. Reinforced for hardware anchorage with not less than 10 gage galvanized steel.

B. Tracks:

1. Manufacturer's standard, formed of galvanized steel.

2. Track Configuration: Standard-lift track.

3. Minimum of 1.98 mm (14 gage) for 50 mm (2 inch) tracks and 2.78 mm

(12 gauge) for 75 mm (3 inch) tracks.

4. Vertical tracks fabricated with adjustable brackets for mounting at incline to continuous steel angle wall bracket.

5. Horizontal Track: Reinforce with continuous steel angle anchored to vertical steel angle wall bracket and to ceiling angle supports.

Provide vertical and cross or diagonal braces to obtain rigid installation of horizontal track.

6. Provide not less than 2.38 mm (13 gage) galvanized steel angles.

C. Hardware:

1. Manufacturers standard hinges, brackets, rollers, and other hardware required for a complete installation.

2. Hinges and Roller Brackets: Minimum of 2.38 mm (13 gage) galvanized steel.

3. Provide rollers with ball bearings and case hardened races.

08 36 13 - 5

4. Provide positive locking device to receive cylinder lock, specified in Section 08 71 00, DOOR HARDWARE, with interlocking switch to motor actuator.

5. Weatherseals: Manufacturer’s standard fitted around entire perimeter of door. Provide combination bottom weatherseal and sensor edge.

D. Manual Operation:

1. Pushup Operation: Provide lifting handles on both sides of door with counterbalance mechanism designed to that required lift or pull for door operation does not exceed 111 newton (N) (25 pound force).

2.4 FINISHES:

A. Steel:

1. Comply with NAAMM’s AMP 500-06 Metal Finishes Manual for recommendations for applying and designating finishes.

2. Clean surfaces free of scale, rust, oil and grease.

3. Baked-Enamel or Powder-Coat Finish: AAMA 2603.

6. Apply shop prime coat of corrosion inhibitive paint on exposed surfaces after fabrication that is compatible with field applied finishes.

7. Apply finish paint of color scheduled when specified in

Section 09 06 00, SCHEDULE FOR FINISHES.

8. Do not paint track, rollers, hinges, or locks.

PART 3 - EXECUTION

3.1 INSTALLATION:

A. Install in accordance with approved shop drawings and manufacturer's instructions.

B. Locate anchors and inserts for tracks, brackets, motors, switches, hardware, and other accessories in accordance with approved shop drawings.

C. Attach tracks to adjoining construction with not less than 9 mm

(3/8 inch) diameter bolts, spaced near each end and not over 610 mm

(24 inches) apart.

D. Lubricate, adjust and demonstrate door to operate freely.

E. Upon completion, leave door openings weathertight and doors free from warp, twists, or distortion.

3.2 REPAIR:

A. Repair zinc-coated surfaces both bare and painted, by the application of galvanizing repair compound.

B. Spot prime and apply finish paint to repairs.

08 36 13 - 6

- - - E N D - - -

File details come from the government source that posted it.